Heater and Air Condition CHAPTER 1
Heater and Air conditioning
CONTENTS
Page
Summary 1---
Data and parameter 1---
Technology maintenance 1---
Condenser
Removal and installation 1
Compressor
Removal and installation 1
Heater unit
Removal and installation 1
Evaporator
Removal and installation 1
Blower unit
Removal and installation 1
Control pad
Removal and installation 1
Inspection and reparation 1---
Troubleshooting
2
REMOVAL STEPS INSTALLATION STEPS
1.unit cover 7.heater steps
2.glove box 6.blower unit
3.fuse and relay box 5.evaporator
4.duct 4.duct
5.evaporator 3.fuse and relay box
6.blow unit 2.glove box
7.heater unit 1.unit cover
Important operation-installation
7.heater unit
6.blower unit
Take measure against water leakage attaching the blower unit
Set the mode change lever to full left position (to the direction of
face)
Set the temperature control lever to full left position (to the
direction of face).
Set the outside inside air control lever to full left (to the
direction of inside).
After hooking the control cable Con the claw of the blower
unit ,set the butterfly too pushed position and fix the cable in the
3
clip.
After hooking the control cable B on the claw of the heater
unit ,set the butterfly to the lowest position and fix the cable in
the clip.
Important operations
1. Always inspect the compressor oil and add if necessary when installing
2. Apply compressor oil to the threads of the flare nut when re-connecting the
4
pipe.
3. Air purge the piping after connecting the pipe ,etc.including each unit before
gas charging .
Insufficient air purging may cause the expansion value clogging.
4. Release gas gradually to prevent compressor oil from spouting out
when removing the pipe.
5. Follow the manufactures instructions because the gas charging
method differs depend on manufacturers when charging gas.
6. Make sure that there is no gas left after charging gas.
5
6
NHR A/C CIRCUIT DIAGRAM
7
NHR promoted A/C
ELECTRIC CIRCUIT DIAGRAM
8
NHR AIR CONDITIONING
TEMPERATURE CONTROL
9
ELECTRIC TEMPERATURE CONTROL (NEW)
NHR PROMOTED A/C
The way to confirm normal range of A/C exhaust pressure according to experience:
Multiply the environment by 2 and 2.5 respectively, and add 10F to each product ,then get the normal
range of exhaust pressure.
10
For example:
Environment temperature is 35 , the normal range of all exhaust pressure can be count by the way as
follows:
(1)F=9/5+32=9/5*35+32=95 (F)
(2)Psi=95*2+10----95*2.5+10
=200----247.5
=6.89476*200Kpa----6.89476*247.5Kpa
=1378.952Kpa---1700.4531Kpa
formula:
F=9/5+32
LPsi=6.89476KPa
11
Air compressor
Heating unit
air mixture
Type : (L*H*W) 161*63*55
Core dimension: mm 4000kcal/h
power: (L*H*W) 230*170*40(2002type)
Core dimension: mm 5900kcal/h(500m3/h)
power:
Cooling unit
serpentine evaporator
Type: 220*188*97
Evaporator dimensions: mm 3400kcal/h(40m3/h)
Evaporator power:
serpentine evaporator
Type: (L*H*W) 371*231.8*85(2002type)
Evaporator dimensions: mm 4500w (500m3/h)
Evaporator power:
Condenser
aluminum parallel flow
Type: 12000kcal/h (4.5m/s)
power:
300ml R134a
Receiver-dehydrator:
brand of R134a,capacity of 0.9Kg
Refrigerant: idle promoted electro magnetic valve
Fast idle device:
12
Blower motor turns but heat air is not
being delivered to outlets
troubleshooting
Sharp kinks or
ok
bending or clogging
replace
Check defroster
to heater
connections
ok wrong
ok ok
replac
e
13
Blower speed can not be regulated
disconnection
ok
replace
ok fault
replace
Blower motor
inoperati
Check fuse
ok faul
t
replace
Open or disconnected
ok
replace
ok disconnect
replace
Check blower motor
14
defective
ok
replace
ok Breakag
e
replace
replace
Check expansion valve
ok faulty
replace
ok faulty
replace
15