C125-E008G

RF-5301PC

Shimadzu
Spectrofluorophotometer
Worlds Highest Level Performance and WindowsTM Software
F ro m R o u tin e A n a lys is To Research Employing The Highest Level Of
S e n s i t i v i ty In T h e Wo rld !

Compared to adsorbance methods, fluorescence sensitivity is tens to thousands times better this means
that you can analyze nanogram to picogram samples with great results.
Fluorescence can be used also to identify a specific molecule in a complex background.
When the compound of interest does not exhibit natural fluorescence, functional group-specific probes may
be used to label the compound and assist your research. The synchronous scanning mode allows mixtures of
fluorochromes to be analyzed.

The personal computer directly controls the instrument for data acquisition and processing.
The Windows friendly operating environment allows you to perform measurement, data processing,
TM

editing and recording in one continuous operation with a click of the mouse. Using the Copy Graph function,
measurement data or spectra may be easily transferred to word processing or spreadsheet software for
preparation of documents or additional calculations.

The essence of fluorescence analysis is sensitivity. The high throughput optical system in the RF-5301PC
employs a blazed holographic granting, photomultiplier and digital circuit to provide the highest level S/N
ratio attainable.

2
Open Up a New Spectrum of Fluorescence Analysis.

High Speed Scanning Varsatile Sample Vertical Optics With


High speed scanning up to Compartment Size Dynode Feedback
5,500nm/min allows you to measure Verticl optics in the RF-5301PC
a spectrum in seconds. And since minimize light loss in measurement
monochromator slewing is about with an LC flow cell, a micro cell or
20,000nm/min, setting of two or small test tube. This design assures
more wavelengths can be exceptionally high signal to noise
performed quickly and easily. ratio and provides the ability to
attain excellent analysis results
High Resolution And using very small volumes of
Extended Range precious samples.
The bandpass on the RF-5301PC The dynode feedback enhances
may be set as narrow as 1.5nm, RF-5301PC performance by raising
which makes is possible to The sample compartment or lowering negative high voltage to
distinguish fluorescent peaks from measuring 140mm wide, 170mm the detector in response to different
the background emission. deep and 140mm high, enables use wavelengths. Dynode feedback
The wavelength range of 220 to of micro cells, high sensitivity cells, which expands the dynamic range
750nm can be extended to 900nm or LC flow cells, etc., for a wide of signal detecting system is
with an optional R-928 range of applications. significantly superior to ratio
photomultiplier. methods.
U n iq u e High
Built-In Performance Checks P e rfo rmance Feat ures In Automatic Shutter
T h e R F- 5301PC Protects Sample
Wavelength search function allows An automatic shutter in the
the optimum excitation and RF-5301PC excitation path closes
emission wavelengths to be found immediately when measurement
in about two minutes. ceases, thereby protecting the
sample from photo-decomposition.

When the instrument is switched


ON, operating conditions of the
spectrophotometer are
automatically verified. Separately, a
noise level (S/N ratio) and light
source (Xenon lamp) usage are
built-in features to help maintain the
instrument in its optimum condition,
providing absolute confidence in the
quality the data.

3
Now You Can Really Put Your Data
Se e T h e Differe n ce with Windows T M Performance

Working in the Windows TM


Many Convenient And Spectrum Measurement
environment makes operation Time-Saving Features Mode
intuitive. The software is driven by The RF-5301PC software is the Perform emission and excitation
pull-down menus displayed at the ideal software to meet all your scans with ease, or overlay the two
top of your screen, that can be fluorescence research needs, from for interpretation. Obtain and
selected with just a click of the teaching to method development differentiate excitation and emission
mouse. For the beginner, on-line and quality assurance. Follow spectra using color and line pattern
HELP is available to guide you changes in intensity over time for assignments. Zoom in using the
through each function. You can kinetic assays or perform mouse or zoom out with the radar
customize the software with quantitative analysis on several function to autoscale all data on-
SpeedBox , an innovative tool that
TM
samples. Youll save time and effort screen. The software picks and
eliminates keystrokes and enables with features that allow for onscreen tabulates peaks and valleys
you to assign icons for commonly data manipulation. automatically. And if you need a fast
used menu commands. With the spectal scan in any measurement
RF-5301PC software, storage, Quantitative Measurement mode, the PopUp Scan function
TM

retrieval and other file management Mode displays it on-screen in seconds.


is quick and simple. Our quantitative analysis uses 1 to
20 known fluorescence standards to
fit the best calibration curve to your
data. Methods such as DNA
quantification with Ethidium
Bromide or Hoechst dye, OPA-
derivatives of amino acids, cell
viability assays and FITC or
Rhodamine-labeled ligands are
handled with ease. The results are
instantly displayed on-screen,
allowing you to read and average Up to 10 spectra may be displayed
the relative fluorescence intensities together on the screeneach
of unknown samples. Optimize your discriminated by an individual color
analyses with first through third and line style. Then, arithmetic
order curve fits. If desired, the curve operations may be conducted
may be forced through zero. To among the spectra to uncover
facilitate your calculations, the hidden information or smooth a
calibration curve is automatically curve.
genetated and is displayed
graphically as well as in tabular
from.

4
In Its Place.

Time Course Measurement One-touch Operation The obtained spectrum may be


Mode With Speed Box TM
further analyzed using data
Working in Time Course allows you For convenience of operation, processing functions, for performing
to monitor experimental changes frequently used functions can be spectral correction and extraction of
and measure reaction rates such as assigned to an accelerator button. hidden information. Any of these
dehydrogenase or -galactosidase functions may be easily executed
activity while the software provides graphically using the mouse.
mathematical support for rate
calculations. Data can be collected Repor t Generation
every 0.02 seconds for the most
timely results.

Then these functions can simply be


executed by clicking-on the as-
signed button. Shape and position
of buttons may be freely customized
by the user.
Before you generate a report, you
may choose to preview it on-screen.
Time Course data may be added, Simple, But Powerful For
Extensive Data Processing To store files for future use, simply
subtracted, multiplied or divided by save them to disk or convert them
each other or a factor. High Operations such as first through
to an ASCII file for accessibility by
sensitivity a stable baseline and 20 fourth order derivative,
other software. Finally, when youre
bit high resolution A/D converter mathematical smoothing functions,
ready to print, the software offers
mean reliable detection of small log conversions and offsets are
the option of sending reports to
changes in fluorescence allowing easily performed with the
either a dot matrix printer for rapid
signal discrimination on small RF-5301PC software. Display up to
output of tables or to a graphics
concentrations. ten spectral curves simultaneously
printer/plotter for publishable quality
Activity calculations are also or use mathematical
graphics and data.
supported, making this transformations to maximize your
measurement mode quite suitable results. Select the source and
Using Copy&Paste, data may be
for enzyme research. destination channels along with the
pasted into other Windows
desired calculation and the results
applications, such as Microsoft
are redisplayed on the screen.
Word for Windows and Excel, to
enable high level report generation.

5
Ve rs a t i l e A p p lic a tio n s Mak e The RF- 5301PC
T h e Pe rfe c t Par tn er F o r A ny Laborat or y

Pharmaceuticals And Pharmacology


The RF-5301PC is excellent for the analysis of crude drugs; quality
control of drugs; quality control of pharmaceuticals or studies on drug
metabolism. Typically, studies would encompass: barbituric acid,
tetracycline, reserpine, LSD, purine and pyrimidine analogs,
porphyrins, etc.

Biochemistry
The RF-5301PC is the instrument of choice for the detection and
measurement of a wide variety of biological samples, even at trace
quantity levels. Typical applications include: enzymes and coenzymes
such as cytochrome oxidase, protein kinase, derivatized lipids, retionids,
NADH, FAD, vitamins, nucleic acids, amino acids, chlorophyll,
neurotransmitters, cell membranes and enzyme kinetics.

Food Science
The RF-5301PC is especially suitable for the detection and measurement
of trace components in a wide variety of foods.
Typical applications include: amines and amino acids, fats, carbohydrates,
coenzymes, antibiotics, food additives, edible oils and pesticides.

Environmental Monitoring
A growing application of the RF-5301PC includes the monitoring,
analysis and study of water, environmental and food pollutants. Typical
studies include: polynuclear aromatics, phenols, oil contaminants and
ground water effluents.

Chemical Analysis
The RF-5301PC is the perfect alternative for the measurement of trace
components of organic and inorganic compounds, unmeasurable by
absorption spectrophotometry. Typical applications include: polymers,
texiles, plastics, rubber, optical materials research, polynuclear aromatic
compounds, petroleum products and kerosene.

6
S pe ci fi cati on s

Light source 150W Xenon lamp. Ozone resolving type lamp housing.

Excitation and emission Concave, blazed holographic grating, F/2.5, 1300 grooves/mm.

monochromators
H a rdw a re Wavelength scale 220-990nm.
S pe c i f i c a t i o n s
Measuring wavelength range 220-750nm and 0 order as standard. 220-900nm with the optional R928 photomultiplier.

Spectral bandwith 6-step selection of 1.5, 3, 5, 10, 15 and 20nm.

(6nm bandwith is available for half sample height on the excitation side only.)

Wavelength accuracy 1.5nm.

Light source compensation Dynode feedback system with monochromatic light monitoring.

Sensitivity The S/N ratio is 150 or higher for the Raman line of distilled water

(350nm excitation wavelength, 5nm spectral band width, and 2 second response for 98% of the full scale).

Wavelength scanning 7-step selection of Survey (about 5500nm/min), Super (about 3000nm/min)

Very Fast, Fast, Medium, Slow and Very Slow.

Wavelength slewing speed About 20,000nm/min.

Response 8-step selection of 0.02, 0.03, 0.1, 0.25, 0.5, 2, 4 and 8 seconds for 98% of the full scale.

Sensitivity selection 2-steps of HIGH and LOW. (The sensitivity at HIGH is about 50 times that of LOW.)

Interface RS-223C interface, interface for autosampler, and interface for sipper unit.

Dimensions and weight 667W x 530D x 270H mm; 43kg.

Power requirements 100, 120, 220, 240V; 50/60Hz; 400VA.

Operational temperature range 15-35C

Operational humidity range 40-80% (Below 70% with temperature higher than 30C).

Measurement Excitation, emission and synchronous spectrum measurement, time-course measurement,

quantitation, automatic search of optimal excitation and emission wavelengths, PopUp Scan . TM

Data processing Arithmetic calculation between spectrum and a constant, smoothing, 1st through
S oft w a re 4th derivatives, 1/Y, logarithmic conversion, data printout (with or without activity
S pe c i f i c a t i o n s value computation), peak pick, point pick, area calculation, averaging

(in quantitation), generation of calibration curves of 1st through 3rd order.

Filing Save, recall, and delete, of data. Conversion into ASCll and DIF formats.

Data output Automatic scale adjustment, readout of data at user-specified point, data printout

(preview function provided), selection of colors and tyoes of curves.

Maintenance Automatic monitoring of signal-to-noise ratio, monitoring of the run time of light source lamp.

User interface SpeedBox (assign icons for commonly used menu commands).
TM

Other functions Data exchange via clipboard, auto response control, automatic shutter.

PC requirements IBM-PC/AT or 100% compatible; i486 or higher CPU; 8 Mbyte or larger main

memory. Operates on MS-Windows version 3.1 or higher.

Windows is a registered trademark of Microsoft Corp. SpeedBox and PopUp Scan are registered trademarks of Shimadzu Scientific Instruments,

7
A W i d e Variety Of O p tio n al Accessories For The RF- 5301PC

C on s t a n t - T e mp e ra tu re N o n -Fluorescent High Sensit ivity


F ou r C e l l H o ld er C ell Cell Holder
Cat, No. 204-03243 Cat, No. 200-34594-03 Cat, No. 204-26841-01

Keeps four sample cells at the Provides a 10mm square non- This cell holder enhances the
desired constant temperature via fluorescent cell, polished on four sensitivity two to three times or
connection to a water bath. sides. This cell is recommended for more. This is recommended for low
Note: Requires the Temperature trace analysis particularly when low concentrations. The excitation and
Controlled Water Bath. UV wavelengths are used for emission beams are repeatedly
excitation. Does not fluoresce when reflected through the sample to
excitation wavelengths from 240 to increase the excitation efficiency.
260nm are used.

Mi c r o C e l l H old er Qu art z Cell Polished R- 928- 08


w i th M i c ro C ell o n Four Sides Phot omult iplier
Cat, No. 204-27125 Cat, No. 200-34441 Cat, No. 200-75021

Provides a 10mm square cell, polished


Permits measurement of samples on four sides. Recommended for Extends the measuring wavelength
as small as 400L in volume. work in the visible range. range from 750 to 900nm.
The cell is installed in an adapter of This cell has a slight absorption at
the same dimensions as an ordinary 260nm and shows small
10mm square cell, so it can be fluorescence intensity at 400nm.
placed in the standard cell holder.

8
S ol i d ( P o w d e r) F lo w -Thru Cell Unit 8mm dia.
Sample Holder fo r H PLC ( 12 L) Test Tube Holder
Cat, No. 204-26836-01 Cat, No. 204-05566 Cat, No. 204-05853

Provides a means to examine the With this attachment, the RF- Holds a test tube, 8mm outer
fluorescence of a solid sample. The 5301PC is used as a highly diameter and 45mm~100mm long.
angle of the holder is designed to sensitive spectral fluorescence The minimum sample volume
limit the reflected excitation beam monitor in HPLC. required is 400L.
from the emission monochromator. Free selection of the excitation and
Standard accessories include a emission wavelengths permits
sample holder, quartz plate, powder selective detection. The mobile 12mm dia.
sample plate, spacers and a sample phase stream can be stopped for Test Tube Holder
fixing bar. Cutoff filters are included spectral measurement, so that Cat, No. 204-03293
to reduce scattering further (UV-31, chromatographic peaks can be
UV-35, UV-39, UV-Y43, UV-Y45, qualitatively determined with higher
UV-Y47). reliability. The flow-thru cell is a
square type with an inner volume as
small as 12L, and is made of
silica, ensuring minimized light
scattering.

F lo w Cell Unit ( 120L)


fo r L C Applicat ion Holds a test tube, 12mm outer
Cat, No. 204-06249 diameter and 60mm~100mm long.

The square micro-flow cell has an


inner volume of 120L and is made
of silica to ensure minimum light
scattering. The inlet and outlet
tubes are both made of vinyl resin
and are 0.5mm I.D. and 2mm O.D.

9
A W i d e Variety Of O p tio n al Accessories For The RF- 5301PC

B ott o m R i s e C o n st ant - Temperat ure Polarizer At t ach m en t


S a mp l e S t a g e S in gle Cell Holder ( f or UV/Vis reg io n )
Cat, No. 204-04811 with St irrer Cat, No. 204-03290
Cat, No. 206-88950-91 (100V)
Cat, No. 206-88950-92 (120V)
Polarizer At t ach m en t
Cat, No. 206-88950-93 (220/240V) ( f or Vis region )
Cat, No. 204-03290-01

Raises the sample cell position in


order to reduce the minimum
sample volume to 1.5mL.
Measurement of fluorescence
Keeps sample at the desired polarization provides information on
constant temperature during the size, fluidity and environments
measurement by circulating of fluorescent molecules. Permits
temperature controlled water reliable measurement of
(5~70C) around the sample cell. polarization characteristics over a
The stirring option has variable wide wavelength range from 240nm
speed control and the minimum to 800nm.
sample volume is 2mL. Effective for
fluorometry of suspended cell
samples.
Note: Does not include the
Temperature Controlled Water Bath.
Not applicable to samples having a
specific gravity greatly different from
that of the solvent.
Note: The hose joint is applied to
6~9mmID tube.

10
N T T-2 2 0 0 P C o nstan t- F ilter Set ASC- 5 Aut o Sam p le
T e m p e ra t u re W ater Cat, No. 204-04691 Changer
C i r c ul a t o r Cat, No. 204-09100
Includes 8 filters: two broad-band
Cat, No. 208-97263
interference filters U-340 and
B-390 for isolation of excitation
wavelengths of 300-380 and 350-
450nm, respectively. Six cutoff
filters: UV-29, L-41, Y-46, Y-50,
O-56 and R-60 with approximately
50%T at 300, 420, 460, 500, 560
and 600nm, respectively.

S p e c tr a Correct ion Builds an automatic multi sample


A c c e s sory spectrophotometry system in
Cat, No. 204-07550 combination with a sipper unit.
Circulates temperature controlled Up to 100 test tubes are set
water to a constant-temperature cell Used to correct excitation and together on the rack. The aspirating
holder. emission spectra in the wavelength nozzle is programmable to move X,
-Temperature range: Ambient + 5C to + 80C region from 250nm to 600nm, using Y and Z (vertical) direction.
-Temperature control precision: 0.05C~ rhodamine solution as the reference
-Max. pumping rate: 27/31 L/min, (quantum counter).
9.5/13m (50/60Hz) Sipper Unit 5300
-External circulation nozzle: 10.5mm Cat, No. 206-83000-91
R e c tangular Flow Cell,
OD (both outlet and return)
12 0 L
-Tank capacity: About 10L (9L during use)
Cat, No. 204-03285-04
-Safety feature: Detection of over-
temperature of Upper or Lower Used for fluorescence monitoring of
limits, Detection of heater wire effluents in column chromatography.
malfunction, Protection of heating Made of fused silica. Requires
too few circulating water, Detection adapter 206-83934-91
of sensor malfunction, Independent
over heat protection, Over current
circuit protector
-Standard accessories: Lid with Aspirates solution samples, using a
handles, Rubber hose (4m, 9mm peristaltic pump driven by a
ID), Hose clamps (4pc.), Instruction stepping motor, to be measured
manual successively. Minimum sample
-Dimensions: 270W x 560H x 400D (mm) volume is 2mL, Linked operation
-Power requirements: 100VAC, with the ASC-5 Auto Sampler
1250VA, with 1.7m power cord and possible.
grounded plug
Note: Piping to Constant-
Temperature Cell Holder (No.206-
88950-**) is possible by the hose
(9mm ID) of accessories.

11
A n o t h e r SH IMA D Z U F lu o res cence Spect rophot omet er
To M a t ch Yo u r N e e d s.

Fluorescence
Spect rophot omet er
RF-1501
The RF-1501 simply outperforms every other
instrument in its class.
High sensitivity gives you the ability to measure
very small samples and detect trace concentrations.
Compact design and availability of inexpensive
program packs for kinetics, intracellular calcium
and time course make it easily expandable.
Other options include software for PC
management.

JQA-0376

SHIMADZU CORPORATION. International Marketing Division


3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101-8448, Japan Phone: 81(3)3219-5641 Fax. 81(3)3219-5710
Cable Add.:SHIMADZU TOKYO
SHIMADZU SCIENTIFIC INSTRUMENTS, INC.
7102 Riverwood Drive, Columbia, Maryland 21046, U.S.A.
Phone: 1(410)381-1227 Fax. 1(410)381-1222 Toll Free: 1(800)477-1227
SHIMADZU EUROPA GmbH
Albert-Hahn-Strasse 6-10, 47269 Duisburg, F.R. Germany Phone: 49(203)7687-0 Fax. 49(203)766625
SHIMADZU (ASIA PACIFIC) PTE LTD.
16 Science Park Drive #01-01 Singapore Science Park, Singapore 118227, Republic of Singapore
Phone: 65-6778-6280 Fax. 65-6779-2935
SHIMADZU SCIENTIFIC INSTRUMENTS (OCEANIA) PTY. LTD.
Units F, 10-16 South Street Rydalmere N.S.W. 2116, Australia
Phone: 61(2)9684-4200 Fax. 61(2)9684-4055
SHIMADZU DO BRASIL COMRCIO LTDA.
Avenida Marqus de So Vicente, 1771. Barra Funda CEP : 01139-003-So Paulo-SP, Brasil
Phone: (55)11-3611-1688 Fax. (55)11-3611-2209
SHIMADZU (HONG KONG) LIMITED
Suite 1028 Ocean Center, Harbour City, Tsim Sha Tsui, Kowloon HONG KONG
Phone: (852)2375-4979 Fax. (852)2199-7438
SHIMADZU INTERNATIONAL TRADING (SHANGHAI) Co., LTD. SHANGHAI OFFICE
24th Floor, Shanghai Xin Hualian Building, No.755 Huaihai Zhong Lu, Shanghai, China
Phone: 86-21-6472-8442 Fax. 86-21-6472-8648
Overseas Offices
Istanbul, Moscow

URL http://www.shimadzu.com The contents of this brochure are subject to change without notice.

Printed in Japan 3295-08618-30ANS

Potrebbero piacerti anche