Sei sulla pagina 1di 437

Report No.

: 10A112301EL-02 Page 1 of 46

Test Report

(Declaration of Conformity)

for

Electromagnetic Compliance

of

Product Switching Power Supply


Trade Name MEAN WELL
Model Number HLx-80H-yz
(x=G, N, P; y=12, 15, 20, 24, 30, 36, 42, 48, 54; z=A or B or D or Blank)
HLG-80H-xBL
(x=12, 15, 20, 24, 30, 36, 42, 48, 54)

Prepared for

MEAN WELL ENTERPRISES CO., LTD.


No.28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 248,
Taiwan (R.O.C.)
TEL.: +886 2 2299 6100
FAX.: +886 2 2299 6200

Prepared by

Interocean EMC Technology Corp.


No. 5-2, Lin 1, Tin-Fu, Lin-Kou Dist., New Taipei City,
Taiwan 244, R.O.C.
TEL.: +886 2 2600 6861
FAX.: +886 2 2600 6859
Remark:
The test report consists of 46 pages in total. It shall not be reproduced except in full,
without the written approval of IETC. This document may be altered or revised by
IETC only, and shall be noted in the revision section of the document.
The test result in this report is only subjected to the test sample.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 2 of 46

Table of Contents

1 General Information 5
1.1 Description of Equipment Under Test 5
1.2 Specifications 6
1.3 Details of Tested Supporting System 7
1.4 Test Facility 8
1.5 Measurement Uncertainty 9
1.6 Configuration of EUT Setup 10

2 Main Terminal Disturbance Voltage Measurement 11


2.1 Instrument 11
2.2 Block Diagram of Test Configuration 11
2.3 Conducted Limit 11
2.4 Instrument Configuration 12
2.5 Configuration of Measurement 12
2.6 Test Result 12

3 Control Terminal Disturbance Voltage Measurement 21


3.1 Instrument 21
3.2 Block Diagram of Test Configuration 21
3.3 Conducted Limit (Control Terminal) 21
3.4 Instrument Configuration 22
3.5 Configuration of Measurement 22
3.6 Test Result 22

4 Radiated Disturbance (9 kHz to 30 MHz) Measurement 27


4.1 Instrument 27
4.2 Block Diagram of Test Configuration 27
4.3 Radiated Electromagnetic Disturbance Limit 27
4.4 Instrument Configuration 28
4.5 Configuration of Measurement 28
4.6 Test Result 28

5 Radiated Disturbance (30 MHz to 300 MHz) Measurement 35


5.1 Instrument 35
5.2 Block Diagram of Test Configuration 35
5.3 Radiated Limits 35
5.4 Instrument Configuration 36
5.5 Configuration of Measurement 36
5.6 Test Result 36

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 3 of 46
6 Performance Criterion of Immunity Test 41
6.1 EN 61547 41

7 Electrical Fast Transient/Burst Immunity Test (EN 61000-4-4) 42


7.1 Instrument 42
7.2 Block Diagram of Test Configuration 42
7.3 Test Levels 42
7.4 Test Requirement 43
7.5 Configuration of Measurement 43
7.6 Test Result 43

8 Photographs of Test 44
8.1 Main Terminal & Control Terminal Disturbance Voltage Measurement 44
8.2 Radiated Disturbance (9 kHz to 30 MHz) Measurement 45
8.3 Radiated Disturbance (30 MHz to 300 MHz) Measurement 46

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 4 of 46

Statement of Compliance
Applicant: MEAN WELL ENTERPRISES CO., LTD.
Manufacturer: 1. Mean Well Enterprises Co., Ltd.
2. Mean Well (GUANGZHOU) Electronics Co., Ltd.
3. SuZhou Mean Well Technology Co., Ltd.
Product: Switching Power Supply
Model No.: HLx-80H-yz
(x=G, N, P; y=12, 15, 20, 24, 30, 36, 42, 48, 54; z=A or B or D or Blank)
HLG-80H-xBL
(x=12, 15, 20, 24, 30, 36, 42, 48, 54)
Tested Power Supply: 230Vac, 50Hz; 110Vac, 60Hz
Date of Final Test: Aug. 14, 2015
Revision of Report: Rev. 02
Measurement Procedures and Standards Used

Emission: Immunity:
EN 55015: 2013 EN 61547: 2009
EN 61000-3-2: 2014 EN 61000-4-2: 2009
EN 61000-3-3: 2013 EN 61000-4-3: 2006+A1: 2008+A2: 2010
EN 61000-4-4: 2012
EN 61000-4-5: 2006
EN 61000-4-6: 2014
EN 61000-4-8: 2010
EN 61000-4-11: 2004

The measurement results in this test report were performed at Interocean EMC Technology
Corp. the responsibility of measurement result is only subjected to the tested sample.
This report shows the EUT is technically compliance with the above official standards.
This report shall not be partial reproduced without written approval by Interocean EMC
Technology Corporation.

Report Issued: 2015/10/23

Project Engineer: Approved:


Vic Tsao Wilson Chang

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 5 of 46

1 General Information

1.1 Description of Equipment Under Test


Product : Switching Power Supply
Model Number : HLx-80H-yz
(x=G, N, P; y=12, 15, 20, 24, 30, 36, 42, 48, 54; z=A or B or D or Blank)
HLG-80H-xBL
(x=12, 15, 20, 24, 30, 36, 42, 48, 54)
Applicant : MEAN WELL ENTERPRISES CO., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 248,
Taiwan (R.O.C.)
Manufacturer : 1. Mean Well Enterprises Co., Ltd.
No.28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 248,
Taiwan (R.O.C.)
2. Mean Well (GUANGZHOU) Electronics Co., Ltd.
2F, A Building, Yuean Industrial Park, Huangcun, Dongpu Town,
TianHe District, Guangzhou, Guangdong, P.R. China
3. SuZhou Mean Well Technology Co., Ltd.
No. 77, Jian-min Road, Dong-qiao, Pan-yang lnd. Park, Huang-dai Town,
Xiang-cheng District, Suzhou, Jiangsu 215152, P.R. China
Product Information : Input: 100-240Vac, 50/60Hz, 0.85A;
277Vac, 50/60Hz, 0.40A
(277Vac for North America only)
Power Cord: Non-shielded, Un-detachable, 0.3 m, w/o core
Output: The detailed specification, please see Specifications as below.
Power Cable: Non-shielded, Un-detachable, 0.3 m, w/o core
Date of Test : Aug. 06 ~ 14, 2015 (For 10A112301EL-02)
Additional Description : (For 10A112301EL)
1.) The Model Number HLG-80H-12A; HLG-80H-15A; HLG-80H-20A;
HLG-80H-24A; HLG-80H-30A; HLG-80H-36A; HLG-80H-42A;
HLG-80H-48A; HLG-80H-54A; HLN-80H-12A; HLN-80H-15A;
HLN-80H-20A; HLN-80H-24A; HLN-80H-30A; HLN-80H-36A;
HLN-80H-42A; HLN-80H-48A; HLN-80H-54A; HLP-80H-48 are
representative selected in the test and included in this report.
(For 10A112301EL-01)
1.) 10A112301EL-01 is a multiple report of 10A112301EL, the differences
are updated the standard and changed the address of Applicant and
Manufacturer (because of municipality change by government).
These modifications are not influence to the previous test result,
therefore, there is no further test necessary in this report.
(For 10A112301EL-02)
1.) 10A112301EL-02 is a multiple report of 10A112301EL-01, the
difference is updated the standard, therefore re-measured Main
Terminal Disturbance Voltage, Control Terminal Disturbance Voltage,
Radiated Disturbance (9 kHz to 30 MHz), Radiated Disturbance (30
MHz to 300 MHz) and EN 61000-4-4 tests, the rest parts are
identical.
2.) The Model Number HLG-80H-48A; HLG-80H-12B are representative
selected in the test and included in this report.
Interocean EMC Technology Corp. CE Test Report
Report No.: 10A112301EL-02 Page 6 of 46

1.2 Specifications

Output
Model No.
Voltage (Vdc) Current (A)

HLx-80H-12z; HLG-80H-12BL 12 5

HLx-80H-15z; HLG-80H-15BL 15 5

HLx-80H-20z; HLG-80H-20BL 20 4

HLx-80H-24z; HLG-80H-24BL 24 3.4

HLx-80H-30z; HLG-80H-30BL 30 2.7

HLx-80H-36z; HLG-80H-36BL 36 2.3

HLx-80H-42z; HLG-80H-42BL 42 1.95

HLx-80H-48z; HLG-80H-48BL 48 1.7

HLx-80H-54z; HLG-80H-54BL 54 1.5


Remark:

1. HLx-80H-yz (x=G stand for metal enclosure with potting compound, N stand
for plastic enclosure without potting compound, P stand for open frame type;
y=12, 15, 20, 24, 30, 36, 42, 48, 54 for output voltage;
z=A or B or D or Blank)

2. HLG-80H-xBL (x=12, 15, 20, 24, 30, 36, 42, 48, 54)

3. Models HLG-80H-xBL (x=12, 15, 20, 24, 30, 36, 42, 48, 54) are identical to
HLx-80H-yz except for the wires termination shall be inside a junction box.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 7 of 46

1.3 Details of Tested Supporting System


1.3.1 Load (HLG-80H-48A)
LED Mode (LM 100%) : 81.6W (48Vdc, 1.7A)

1.3.2 Load (HLG-80H-12B)


LED Mode (LM 100%) : 60W (12Vdc, 5A)

1.3.3 Power Cord (For Emission Measurement)


Power Cord : Non-shielded, Detachable, 1.5 m, w/o core

1.3.4 Power Cable


Power Cable : Non-shielded, Detachable, 0.7 m, w/o core

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 8 of 46

1.4 Test Facility


Site Description : Conducted 1 OATS 1 EMS Room
Name of Firm : Interocean EMC Technology Corp.
Company web : http://www.ietc.com.tw
Location : No. 5-2, Lin 1, Tin-Fu, Lin-Kou Dist., New Taipei City,
Taiwan 244, R.O.C.
Site Filing : Federal Communication Commissions USA
Registration No.: 96399 (OATS 1, 2, 3 & Chamber 3)
Designation No.: TW1020
Industry Canada (IC)
OUR FILE: 46405-4437
Registration No. (OATS 1): Site# 4437A-1
Registration No. (OATS 3): Site# 4437A-3
Registration No. (Chamber 3): Site# 4437A-5
Registration No. (OATS 5): Site# 4437A-6
Voluntary Control Council for Interference by Information
Technology Equipment (VCCI) Japan
Member No.: 1349
Registration No. (Conducted Room): C-1094
Registration No. (Conducted Room): T-1562
Registration No. (OATS 1): R-1040; G-274
Site Accreditation : Bureau of Standards and Metrology and Inspection (BSMI)
Taiwan, R.O.C.
Accreditation No.:
SL2-IN-E-0026 for CNS13438 / CISPR 22
SL2-IN-E-0026 for CNS14757-2 / IEC 62040-2
SL2-R1-E-0026 for CNS13439 / CISPR 13
SL2-R2-E-0026 for CNS13439 / CISPR 13
SL2-A1-E-0026 for CNS13783-1 / CISPR 14-1
SL2-L1-E-0026 for CNS 14115 / CISPR 15
Taiwan Accreditation Foundation (TAF)
Accreditation No.: 1113
Vehicle Safety Certification Center (VSCC)
Approval No.: TW16-11-0
TV NORD
Certificate No: TNTW0801R-04

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 9 of 46

1.5 Measurement Uncertainty


Item Value
Conduction 1:
Conducted Emission - AMN (9 kHz to 30 MHz) 2.98 dB
Conducted Emission - AAN (ISN-T4) (150 kHz to 30 MHz) 3.70 dB
Conducted Emission - AAN (ISN-T8) (150 kHz to 30 MHz) 3.70 dB
Conducted Emission - CP (9 kHz to 30 MHz) 3.06 dB
Conducted Emission - VP (9 kHz to 30 MHz) 2.42 dB
Radiated Emission - LAS (2 m Loop) (9 kHz to 30 MHz) 3.26 dB
Conduction 2:
Disturbance Power (30 MHz to 300 MHz) 4.04 dB
OATS 1:
Radiated Emission Test (30 MHz to 1 GHz) 5.04 dB
Radiated Emission Test (1 GHz to 6 GHz) 4.98 dB
OATS 3:
Radiated Emission Test (30 MHz to 1 GHz) 5.04 dB
OATS 5:
Radiated Emission Test (30 MHz to 1 GHz) 5.04 dB
Chamber 3:
Radiated Emission Test (30 MHz to 1 GHz) 5.16 dB
Radiated Emission Test (1 GHz to 6 GHz) 4.98 dB
Induced Current Density (20 kHz to 10 MHz) 1.82 dB
Conducted Immunity Room:
Conducted Immunity Test / CDN-M2 1.30 dB
Conducted Immunity Test / CDN-M3 1.30 dB
Conducted Immunity Test / EM Clamp 3.16 dB

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 10 of 46

1.6 Configuration of EUT Setup

Connected to mains

Power Cord

B2

B1
A1 x 2 (+)
EUT A2 x 2 (-) Dummy Load

Power Cable

Remark: 1. For Main Terminal Disturbance Voltage Measurement: The length of


power cord is 1.8 m long, which shall be as near to 1 m as possible,
the excess should be folded at the centre into a bundle no longer
than 0.4 m.
2. The length of power cable is 1 m long.

Connecting Cables:
Shielded Supported
No. Cable Length Shielded Note
Backshell by lab.
A1 Power Cable (+) 1m
A2 Power Cable (-) 1m
B1 Power Cord 0.3 m
B2 Power Cord 1.5 m R

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 11 of 46

2 Main Terminal Disturbance Voltage Measurement

2.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

EMI Test Receiver Rohde & Schwarz ESCS 30 100127 2015/10/20

RF Cable HARBOUR RG58/U CBL48 2016/07/27

L.I.S.N. Schwarzbeck NNLK8121 8121417 2015/08/27

L.I.S.N. Schaffner MN2050D 1598 2015/08/14


Note: The above equipments are within the valid calibration period.

2.2 Block Diagram of Test Configuration

Rear of EUT to be flush with Non-conductive table


rear of table top 0.1m

EMI Test 0.8 m to


Receiver EUT Peripheral
ground
plane

RF Cable

0.8 m

0.4 m
LISN
LISN

Power Cord
0.4 m to vertical ground
Bonded to horizontal
Bonded to horizontal reference plane
ground plane
ground plane

Vertical ground reference plane

2.3 Conducted Limit


Limits dB (V)
Frequency (MHz)
Q.P. (Quasi-Peak) A.V. (Average)
0.009 - 0.05 110 ---
0.05 - 0.15 90 to 80 ---
0.15 - 0.5 66 to 56 56 to 46
0.5 - 5.0 56 46
5.0 - 30 60 50

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 12 of 46

2.4 Instrument Configuration


2.4.1 Set the EMI test receiver frequency range from 9 kHz to 30 MHz.
2.4.2 Set the EMI test receiver bandwidth at 200 Hz, 9 kHz.
2.4.3 Set the EMI test receiver detector as Quasi-Peak (Q.P.) and Average (AV).

2.5 Configuration of Measurement


2.5.1 The EUT was placed on a non-conductive table whose total height equaled 80cm and
vertical conducting plane located 40 cm to the rear of the EUT.
2.5.2 The EUT was connected to the main power through Line Impedance Stabilization Networks
(LISN). This setup provided a 50 ohm / 50 H coupling impedance for the measuring
equipment. The auxiliary equipment was also connected to the main power through a LISN
that provided a 50 ohm/50 H coupling impedance with 50 ohm termination. (Refer to the
block diagram of the test setup and photographs.)
2.5.3 The conducted disturbance was measured between the phase lead and the reference
ground, and between the neutral lead and reference ground. The initial testing identified the
frequency that has the highest disturbance relative to the limit while operating the EUT in
typical modes of operation and cable positions in a test setup representative of typical
system configuration.
2.5.4 The identification of the frequency of highest disturbance with respect to the limit was found
by investigating disturbances at a number of significant frequencies. The probable frequency
of maximum disturbance had been found and that the associated cable and EUT
configuration and mode of operation had been identified.
2.5.5 An initial survey or scan of the complete frequency rang 9kHz to 30MHz shall be made with
full light output. In addition, at the following frequencies and at all frequencies at which there
is a maximum disturbance found in the initial survey, the control setting shall be varied for
maximum disturbance while maintaining the maximum load:
2.5.6 9 kHz50 kHz100 kHz160 kHz240 kHz550 kHz1 MHz1.4 MHz2 MHz3.5 MHz
6 MHz10 MHz22 MHz30 MHz.

2.6 Test Result


PASS.
The final test data is shown as following pages.

Factor = Insertion Loss + Cable Loss


Level = Reading + Factor
Margin = Level - Limit

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 13 of 46
Power Line Conducted Test Data
CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Line
RATING: 230Vac / 50Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (230V)
Data:111 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV dBuV dB

1 0.009 59.04 0.28 59.32 110.00 -50.68 QP


2 0.050 47.94 0.20 48.14 110.00 -61.86 QP
3 0.100 31.61 0.24 31.85 83.68 -51.83 QP
4 0.160 44.79 0.28 45.07 65.45 -20.38 QP
5 0.160 27.21 0.28 27.49 55.45 -27.96 Average
6 0.240 29.13 0.28 29.41 62.08 -32.67 QP
7 0.240 19.57 0.28 19.85 52.08 -32.23 Average
8 0.550 26.66 0.28 26.94 56.00 -29.06 QP
9 0.550 21.93 0.28 22.21 46.00 -23.79 Average
10 1.002 20.71 0.29 21.00 56.00 -35.00 QP
11 1.002 17.19 0.29 17.48 46.00 -28.52 Average
12 1.398 11.74 0.31 12.05 56.00 -43.95 QP
13 1.398 11.38 0.31 11.69 46.00 -34.31 Average
14 1.997 16.57 0.34 16.91 56.00 -39.09 QP
15 1.997 12.78 0.34 13.12 46.00 -32.88 Average
16 2.763 42.69 0.36 43.05 56.00 -12.95 QP
17 2.763 34.75 0.36 35.11 46.00 -10.89 Average
18 3.496 28.85 0.37 29.22 56.00 -26.78 QP
19 3.496 22.76 0.37 23.13 46.00 -22.87 Average
20 6.020 22.78 0.43 23.21 60.00 -36.79 QP
21 6.020 17.32 0.43 17.75 50.00 -32.25 Average
22 10.035 18.67 0.62 19.29 60.00 -40.71 QP
23 10.035 15.11 0.62 15.73 50.00 -34.27 Average
24 22.042 21.09 1.14 22.23 60.00 -37.77 QP
25 22.042 17.31 1.14 18.45 50.00 -31.55 Average
26 30.000 21.13 1.42 22.55 60.00 -37.45 QP
27 30.000 17.33 1.42 18.75 50.00 -31.25 Average

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 14 of 46
Power Line Conducted Test Data
CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Neutral
RATING: 230Vac / 50Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (230V)
Data:110 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV dBuV dB

1 0.009 60.47 0.30 60.77 110.00 -49.23 QP


2 0.050 46.28 0.20 46.48 110.00 -63.52 QP
3 0.100 30.92 0.23 31.15 83.68 -52.53 QP
4 0.160 45.39 0.27 45.66 65.45 -19.79 QP
5 0.160 28.03 0.27 28.30 55.45 -27.15 Average
6 0.240 29.58 0.27 29.85 62.08 -32.23 QP
7 0.240 19.83 0.27 20.10 52.08 -31.98 Average
8 0.550 26.66 0.28 26.94 56.00 -29.06 QP
9 0.550 22.15 0.28 22.43 46.00 -23.57 Average
10 1.002 20.77 0.29 21.06 56.00 -34.94 QP
11 1.002 17.21 0.29 17.50 46.00 -28.50 Average
12 1.398 11.84 0.31 12.15 56.00 -43.85 QP
13 1.398 11.20 0.31 11.51 46.00 -34.49 Average
14 1.997 17.15 0.34 17.49 56.00 -38.51 QP
15 1.997 13.20 0.34 13.54 46.00 -32.46 Average
16 2.719 44.25 0.37 44.62 56.00 -11.38 QP
17 2.719 38.21 0.37 38.58 46.00 -7.42 Average
18 3.496 27.33 0.38 27.71 56.00 -28.29 QP
19 3.496 21.72 0.38 22.10 46.00 -23.90 Average
20 6.020 23.01 0.47 23.48 60.00 -36.52 QP
21 6.020 17.53 0.47 18.00 50.00 -32.00 Average
22 10.035 18.69 0.69 19.38 60.00 -40.62 QP
23 10.035 15.11 0.69 15.80 50.00 -34.20 Average
24 22.042 22.71 1.32 24.03 60.00 -35.97 QP
25 22.042 18.67 1.32 19.99 50.00 -30.01 Average
26 30.000 20.89 1.60 22.49 60.00 -37.51 QP
27 30.000 17.03 1.60 18.63 50.00 -31.37 Average

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 15 of 46
Power Line Conducted Test Data
CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Line
RATING: 230Vac / 50Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 50%) (HLG-80H-12B) (230V)
Data:112 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV dBuV dB

1 0.009 59.64 0.28 59.92 110.00 -50.08 QP


2 0.050 47.43 0.20 47.63 110.00 -62.37 QP
3 0.100 31.29 0.24 31.53 83.68 -52.15 QP
4 0.160 44.97 0.28 45.25 65.45 -20.20 QP
5 0.160 27.59 0.28 27.87 55.45 -27.58 Average
6 0.240 29.88 0.28 30.16 62.08 -31.92 QP
7 0.240 19.75 0.28 20.03 52.08 -32.05 Average
8 0.550 26.66 0.28 26.94 56.00 -29.06 QP
9 0.550 22.11 0.28 22.39 46.00 -23.61 Average
10 1.002 20.71 0.29 21.00 56.00 -35.00 QP
11 1.002 17.21 0.29 17.50 46.00 -28.50 Average
12 1.398 11.68 0.31 11.99 56.00 -44.01 QP
13 1.398 11.22 0.31 11.53 46.00 -34.47 Average
14 1.997 16.61 0.34 16.95 56.00 -39.05 QP
15 1.997 12.82 0.34 13.16 46.00 -32.84 Average
16 2.763 43.62 0.36 43.98 56.00 -12.02 QP
17 2.763 36.35 0.36 36.71 46.00 -9.29 Average
18 3.496 28.25 0.37 28.62 56.00 -27.38 QP
19 3.496 22.36 0.37 22.73 46.00 -23.27 Average
20 6.020 23.08 0.43 23.51 60.00 -36.49 QP
21 6.020 17.90 0.43 18.33 50.00 -31.67 Average
22 10.035 19.27 0.62 19.89 60.00 -40.11 QP
23 10.035 15.51 0.62 16.13 50.00 -33.87 Average
24 22.042 21.01 1.14 22.15 60.00 -37.85 QP
25 22.042 17.17 1.14 18.31 50.00 -31.69 Average
26 30.000 21.05 1.42 22.47 60.00 -37.53 QP
27 30.000 17.23 1.42 18.65 50.00 -31.35 Average

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 16 of 46
Power Line Conducted Test Data
CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Neutral
RATING: 230Vac / 50Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 50%) (HLG-80H-12B) (230V)
Data:113 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV dBuV dB

1 0.009 60.34 0.30 60.64 110.00 -49.36 QP


2 0.050 60.69 0.20 60.89 110.00 -49.11 QP
3 0.100 30.33 0.23 30.56 83.68 -53.12 QP
4 0.160 45.25 0.27 45.52 65.45 -19.93 QP
5 0.160 28.15 0.27 28.42 55.45 -27.03 Average
6 0.240 29.96 0.27 30.23 62.08 -31.85 QP
7 0.240 19.81 0.27 20.08 52.08 -32.00 Average
8 0.550 27.18 0.28 27.46 56.00 -28.54 QP
9 0.550 22.47 0.28 22.75 46.00 -23.25 Average
10 1.002 20.69 0.29 20.98 56.00 -35.02 QP
11 1.002 17.19 0.29 17.48 46.00 -28.52 Average
12 1.398 11.54 0.31 11.85 56.00 -44.15 QP
13 1.398 11.30 0.31 11.61 46.00 -34.39 Average
14 1.997 17.29 0.34 17.63 56.00 -38.37 QP
15 1.997 13.28 0.34 13.62 46.00 -32.38 Average
16 2.741 45.17 0.37 45.54 56.00 -10.46 QP
17 2.741 39.40 0.37 39.77 46.00 -6.23 Average
18 2.997 34.50 0.37 34.87 56.00 -21.13 QP
19 2.997 27.74 0.37 28.11 46.00 -17.89 Average
20 6.020 22.97 0.47 23.44 60.00 -36.56 QP
21 6.020 17.93 0.47 18.40 50.00 -31.60 Average
22 10.035 18.87 0.69 19.56 60.00 -40.44 QP
23 10.035 14.75 0.69 15.44 50.00 -34.56 Average
24 22.042 21.79 1.32 23.11 60.00 -36.89 QP
25 22.042 17.83 1.32 19.15 50.00 -30.85 Average
26 30.000 20.95 1.60 22.55 60.00 -37.45 QP
27 30.000 17.23 1.60 18.83 50.00 -31.17 Average

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 17 of 46
Power Line Conducted Test Data
CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Line
RATING: 110Vac / 60Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (110V)
Data:115 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV dBuV dB

1 0.009 58.11 0.28 58.39 110.00 -51.61 QP


2 0.050 57.14 0.20 57.34 110.00 -52.66 QP
3 0.100 31.51 0.24 31.75 83.68 -51.93 QP
4 0.151 46.29 0.28 46.57 65.92 -19.35 QP
5 0.151 32.52 0.28 32.80 55.92 -23.12 Average
6 0.160 41.49 0.28 41.77 65.45 -23.68 QP
7 0.160 27.53 0.28 27.81 55.45 -27.64 Average
8 0.240 26.50 0.28 26.78 62.08 -35.30 QP
9 0.240 17.43 0.28 17.71 52.08 -34.37 Average
10 0.550 28.68 0.28 28.96 56.00 -27.04 QP
11 0.550 23.65 0.28 23.93 46.00 -22.07 Average
12 1.002 17.11 0.29 17.40 56.00 -38.60 QP
13 1.002 13.99 0.29 14.28 46.00 -31.72 Average
14 1.398 14.41 0.31 14.72 56.00 -41.28 QP
15 1.398 12.26 0.31 12.57 46.00 -33.43 Average
16 1.997 13.89 0.34 14.23 56.00 -41.77 QP
17 1.997 11.70 0.34 12.04 46.00 -33.96 Average
18 2.786 43.26 0.36 43.62 56.00 -12.38 QP
19 2.786 36.54 0.36 36.90 46.00 -9.10 Average
20 3.496 29.61 0.37 29.98 56.00 -26.02 QP
21 3.496 22.48 0.37 22.85 46.00 -23.15 Average
22 6.020 22.74 0.43 23.17 60.00 -36.83 QP
23 6.020 17.06 0.43 17.49 50.00 -32.51 Average
24 10.035 20.39 0.62 21.01 60.00 -38.99 QP
25 10.035 15.77 0.62 16.39 50.00 -33.61 Average
26 22.042 18.45 1.14 19.59 60.00 -40.41 QP
27 22.042 15.27 1.14 16.41 50.00 -33.59 Average
28 30.000 21.81 1.42 23.23 60.00 -36.77 QP
29 30.000 17.61 1.42 19.03 50.00 -30.97 Average

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 18 of 46
Power Line Conducted Test Data
CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Neutral
RATING: 110Vac / 60Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (110V)
Data:114 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV dBuV dB

1 0.009 53.56 0.30 53.86 110.00 -56.14 QP


2 0.050 59.86 0.20 60.06 110.00 -49.94 QP
3 0.100 31.77 0.23 32.00 83.68 -51.68 QP
4 0.160 41.84 0.27 42.11 65.45 -23.34 QP
5 0.160 25.25 0.27 25.52 55.45 -29.93 Average
6 0.240 27.38 0.27 27.65 62.08 -34.43 QP
7 0.240 19.45 0.27 19.72 52.08 -32.36 Average
8 0.550 26.04 0.28 26.32 56.00 -29.68 QP
9 0.550 21.39 0.28 21.67 46.00 -24.33 Average
10 1.002 15.75 0.29 16.04 56.00 -39.96 QP
11 1.002 13.18 0.29 13.47 46.00 -32.53 Average
12 1.398 13.87 0.31 14.18 56.00 -41.82 QP
13 1.398 11.88 0.31 12.19 46.00 -33.81 Average
14 1.997 13.69 0.34 14.03 56.00 -41.97 QP
15 1.997 11.62 0.34 11.96 46.00 -34.04 Average
16 2.763 42.65 0.37 43.02 56.00 -12.98 QP
17 2.763 35.74 0.37 36.11 46.00 -9.89 Average
18 3.496 28.94 0.38 29.32 56.00 -26.68 QP
19 3.496 21.76 0.38 22.14 46.00 -23.86 Average
20 6.020 22.91 0.47 23.38 60.00 -36.62 QP
21 6.020 16.99 0.47 17.46 50.00 -32.54 Average
22 10.035 19.61 0.69 20.30 60.00 -39.70 QP
23 10.035 15.07 0.69 15.76 50.00 -34.24 Average
24 22.042 19.43 1.32 20.75 60.00 -39.25 QP
25 22.042 15.99 1.32 17.31 50.00 -32.69 Average
26 30.000 21.49 1.60 23.09 60.00 -36.91 QP
27 30.000 17.49 1.60 19.09 50.00 -30.91 Average

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 19 of 46
Power Line Conducted Test Data
CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Line
RATING: 110Vac / 60Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 50%) (HLG-80H-12B) (110V)
Data:136 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV dBuV dB

1 0.009 58.98 0.28 59.26 110.00 -50.74 QP


2 0.050 54.25 0.20 54.45 110.00 -55.55 QP
3 0.100 31.33 0.24 31.57 83.68 -52.11 QP
4 0.160 40.65 0.28 40.93 65.45 -24.52 QP
5 0.160 27.97 0.28 28.25 55.45 -27.20 Average
6 0.240 28.56 0.28 28.84 62.08 -33.24 QP
7 0.240 20.49 0.28 20.77 52.08 -31.31 Average
8 0.550 25.78 0.28 26.06 56.00 -29.94 QP
9 0.550 21.09 0.28 21.37 46.00 -24.63 Average
10 1.002 14.49 0.29 14.78 56.00 -41.22 QP
11 1.002 12.84 0.29 13.13 46.00 -32.87 Average
12 1.398 13.69 0.31 14.00 56.00 -42.00 QP
13 1.398 12.54 0.31 12.85 46.00 -33.15 Average
14 1.997 13.61 0.34 13.95 56.00 -42.05 QP
15 1.997 11.80 0.34 12.14 46.00 -33.86 Average
16 2.763 40.78 0.36 41.14 56.00 -14.86 QP
17 2.763 36.57 0.36 36.93 46.00 -9.07 Average
18 3.496 25.93 0.37 26.30 56.00 -29.70 QP
19 3.496 22.66 0.37 23.03 46.00 -22.97 Average
20 6.020 20.80 0.43 21.23 60.00 -38.77 QP
21 6.020 18.24 0.43 18.67 50.00 -31.33 Average
22 10.035 18.03 0.62 18.65 60.00 -41.35 QP
23 10.035 15.89 0.62 16.51 50.00 -33.49 Average
24 22.042 21.07 1.14 22.21 60.00 -37.79 QP
25 22.042 16.61 1.14 17.75 50.00 -32.25 Average
26 30.000 22.07 1.42 23.49 60.00 -36.51 QP
27 30.000 17.93 1.42 19.35 50.00 -30.65 Average

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 20 of 46
Power Line Conducted Test Data
CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Neutral
RATING: 110Vac / 60Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 50%) (HLG-80H-12B) (110V)
Data:137 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV dBuV dB

1 0.009 58.37 0.30 58.67 110.00 -51.33 QP


2 0.050 52.62 0.20 52.82 110.00 -57.18 QP
3 0.100 37.69 0.23 37.92 83.68 -45.76 QP
4 0.160 40.99 0.27 41.26 65.45 -24.19 QP
5 0.160 27.89 0.27 28.16 55.45 -27.29 Average
6 0.240 28.66 0.27 28.93 62.08 -33.15 QP
7 0.240 20.63 0.27 20.90 52.08 -31.18 Average
8 0.550 25.74 0.28 26.02 56.00 -29.98 QP
9 0.550 21.01 0.28 21.29 46.00 -24.71 Average
10 1.002 15.07 0.29 15.36 56.00 -40.64 QP
11 1.002 12.80 0.29 13.09 46.00 -32.91 Average
12 1.398 13.03 0.31 13.34 56.00 -42.66 QP
13 1.398 11.86 0.31 12.17 46.00 -33.83 Average
14 1.997 13.57 0.34 13.91 56.00 -42.09 QP
15 1.997 11.68 0.34 12.02 46.00 -33.98 Average
16 2.786 40.51 0.37 40.88 56.00 -15.12 QP
17 2.786 35.75 0.37 36.12 46.00 -9.88 Average
18 3.496 26.19 0.38 26.57 56.00 -29.43 QP
19 3.496 22.22 0.38 22.60 46.00 -23.40 Average
20 6.020 21.27 0.47 21.74 60.00 -38.26 QP
21 6.020 17.99 0.47 18.46 50.00 -31.54 Average
22 10.035 17.93 0.69 18.62 60.00 -41.38 QP
23 10.035 15.39 0.69 16.08 50.00 -33.92 Average
24 22.042 20.65 1.32 21.97 60.00 -38.03 QP
25 22.042 16.81 1.32 18.13 50.00 -31.87 Average
26 30.000 21.41 1.60 23.01 60.00 -36.99 QP
27 30.000 17.51 1.60 19.11 50.00 -30.89 Average

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 21 of 46
3 Control Terminal Disturbance Voltage Measurement

3.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

EMI Test Receiver Rohde & Schwarz ESCS 30 100127 2015/10/20

RF Cable HARBOUR RG58/U CBL48 2016/07/27

L.I.S.N. Schwarzbeck NNLK8121 8121417 2015/08/27

L.I.S.N. Schaffner MN2050D 1598 2015/08/14

ISN TESEQ GmbH ISN T200A 38296 2016/01/21


Note: The above equipments are within the valid calibration period.

3.2 Block Diagram of Test Configuration


Rear of EUT to be flush with Non-conductive table
rear of table top 0.1m

EMI Test 0.8 m to


RF Cable EUT Peripheral
Receiver ground
plane

Control
Unit
ISN 0.8 m
Bonded to Vertical
ground plane
0.4 m
Telecommunication LISN
Bonded to LISN
horizontal Cable
ground plane
Power Cord 0.4 m to vertical ground
Bonded to horizontal
reference plane
ground plane

Vertical ground reference plane

3.3 Conducted Limit (Control Terminal)


Frequency range Voltage Limits (dBV)
(MHz) Q.P. (Quasi-Peak) A.V. (Average)
0.15 - 0.50 84 to 74 74 to 64
0.50 - 30 74 64
NOTE 1 The limits decrease linearly with the logarithm of the frequency in the range 0.15
MHz to 0.5 MHz.
NOTE 2 The voltage disturbance limits are derived for use with an Asymmetric Artificial
Network (AAN) which presents a common mode (asymmetric mode)
impedance of 150 to the control terminal.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 22 of 46

3.4 Instrument Configuration


3.4.1 Set the EMI test receiver frequency range from 150 kHz to 30 MHz.
3.4.2 Set the EMI test receiver bandwidth at 9 kHz.
3.4.3 Set the EMI test receiver detector as Quasi-Peak (Q.P.) and Average (AV).

3.5 Configuration of Measurement


3.5.1 Measurement is made at control terminal using ISNs with longitudinal conversion losses
(LCL) as defined in EN 55022.
3.5.2 The manufacturer shall demonstrate that the equipment does not exceed the Conducted
limits of control terminal when tested with the ISN according to the cable category specified
by the equipment documentation provided to the user.
An initial survey or scan of the complete frequency range 150 kHz to 30 MHz shall be made
with full light output. In addition, at the following frequencies and at all frequencies at which
there is a maximum disturbance found in the initial survey, the control setting shall be varied
for maximum disturbance while maintaining the maximum load:
160 kHz, 240 kHz, 550 kHz, 1 MHz, 1,4 MHz, 2 MHz, 3,5 MHz, 6 MHz, 10 MHz, 22 MHz &
30 MHz.
3.5.3 Recording of measurements
Of those disturbances above (L-20dB), where L is the limit level in logarithmic units, record
at least the disturbance levels and the frequencies of the six highest disturbances from each
mains port and each telecommunication port, which comprise the EUT. For the mains port,
the current-carrying conductor for each disturbance shall be identified.

3.6 Test Result


PASS.
The final test data is shown as following pages.

Factor = Insertion Loss + Cable Loss


Level = Reading + Factor
Margin = Level - Limit

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 23 of 46
Control Terminal Disturbance Voltage Test Data
CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: ISN
RATING: 230Vac / 50Hz TEMP/HUM: 25.7C / 70%
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (230V) (With Common choke)
Data:202 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-10

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV dBuV dB

1 0.160 28.43 10.30 38.73 83.47 -44.74 QP


2 0.160 23.35 10.30 33.65 73.47 -39.82 Average
3 0.208 45.53 10.22 55.75 81.27 -25.52 QP
4 0.208 41.94 10.22 52.16 71.27 -19.11 Average
5 0.240 21.30 10.20 31.50 80.08 -48.58 QP
6 0.240 19.36 10.20 29.56 70.08 -40.52 Average
7 0.479 32.84 10.11 42.95 74.36 -31.41 QP
8 0.479 28.76 10.11 38.87 64.36 -25.49 Average
9 0.549 30.98 10.10 41.08 74.00 -32.92 QP
10 0.549 23.40 10.10 33.50 64.00 -30.50 Average
11 1.000 22.95 10.06 33.01 74.00 -40.99 QP
12 1.000 19.45 10.06 29.51 64.00 -34.49 Average
13 1.403 28.11 10.06 38.17 74.00 -35.83 QP
14 1.403 19.35 10.06 29.41 64.00 -34.59 Average
15 2.001 29.09 10.06 39.15 74.00 -34.85 QP
16 2.001 20.41 10.06 30.47 64.00 -33.53 Average
17 2.884 43.98 10.05 54.03 74.00 -19.97 QP
18 2.884 37.13 10.05 47.18 64.00 -16.82 Average
19 3.140 34.15 10.05 44.20 74.00 -29.80 QP
20 3.140 28.66 10.05 38.71 64.00 -25.29 Average
21 3.509 33.31 10.05 43.36 74.00 -30.64 QP
22 3.509 23.43 10.05 33.48 64.00 -30.52 Average
23 5.993 24.15 10.01 34.16 74.00 -39.84 QP
24 5.993 20.56 10.01 30.57 64.00 -33.43 Average
25 10.019 23.14 10.08 33.22 74.00 -40.78 QP
26 10.019 20.67 10.08 30.75 64.00 -33.25 Average
27 22.416 33.95 10.17 44.12 74.00 -29.88 QP
28 22.416 29.24 10.17 39.41 64.00 -24.59 Average
29 25.055 35.37 10.17 45.54 74.00 -28.46 QP
30 25.055 30.60 10.17 40.77 64.00 -23.23 Average
31 30.000 30.09 10.19 40.28 74.00 -33.72 QP
32 30.000 26.91 10.19 37.10 64.00 -26.90 Average

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 24 of 46
Control Terminal Disturbance Voltage Test Data
CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: ISN
RATING: 230Vac / 50Hz TEMP/HUM: 25.7C / 70%
COMMENT: Test Mode: LED Mode (LM 50%) (HLG-80H-12B) (230V) (With Common choke)
Data:213 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-10

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV dBuV dB

1 0.160 26.61 10.30 36.91 83.47 -46.56 QP


2 0.160 20.45 10.30 30.75 73.47 -42.72 Average
3 0.208 50.93 10.22 61.15 81.27 -20.12 QP
4 0.208 48.62 10.22 58.84 71.27 -12.43 Average
5 0.240 27.58 10.20 37.78 80.08 -42.30 QP
6 0.240 22.48 10.20 32.68 70.08 -37.40 Average
7 0.310 44.24 10.16 54.40 77.97 -23.57 QP
8 0.310 39.75 10.16 49.91 67.97 -18.06 Average
9 0.408 34.76 10.12 44.88 75.68 -30.80 QP
10 0.408 26.40 10.12 36.52 65.68 -29.16 Average
11 0.549 24.58 10.10 34.68 74.00 -39.32 QP
12 0.549 22.36 10.10 32.46 64.00 -31.54 Average
13 1.000 26.53 10.06 36.59 74.00 -37.41 QP
14 1.000 23.49 10.06 33.55 64.00 -30.45 Average
15 1.403 32.35 10.06 42.41 74.00 -31.59 QP
16 1.403 24.49 10.06 34.55 64.00 -29.45 Average
17 2.001 32.11 10.06 42.17 74.00 -31.83 QP
18 2.001 25.51 10.06 35.57 64.00 -28.43 Average
19 2.721 36.60 10.05 46.65 74.00 -27.35 QP
20 2.721 28.98 10.05 39.03 64.00 -24.97 Average
21 2.915 47.09 10.05 57.14 74.00 -16.86 QP
22 2.915 39.24 10.05 49.29 64.00 -14.71 Average
23 3.509 33.55 10.05 43.60 74.00 -30.40 QP
24 3.509 25.57 10.05 35.62 64.00 -28.38 Average
25 5.993 23.01 10.01 33.02 74.00 -40.98 QP
26 5.993 21.68 10.01 31.69 64.00 -32.31 Average
27 10.019 24.32 10.08 34.40 74.00 -39.60 QP
28 10.019 21.77 10.08 31.85 64.00 -32.15 Average
29 21.946 33.93 10.17 44.10 74.00 -29.90 QP
30 21.946 26.08 10.17 36.25 64.00 -27.75 Average
31 25.591 34.99 10.17 45.16 74.00 -28.84 QP
32 25.591 30.05 10.17 40.22 64.00 -23.78 Average
33 30.000 31.27 10.19 41.46 74.00 -32.54 QP
34 30.000 26.18 10.19 36.37 64.00 -27.63 Average

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 25 of 46
Control Terminal Disturbance Voltage Test Data
CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: ISN
RATING: 110Vac / 60Hz TEMP/HUM: 25.7C / 70%
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (110V) (With Common choke)
Data:190 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-10

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV dBuV dB

1 0.160 37.61 10.30 47.91 83.47 -35.56 QP


2 0.160 32.97 10.30 43.27 73.47 -30.20 Average
3 0.240 30.47 10.20 40.67 80.08 -39.41 QP
4 0.240 28.12 10.20 38.32 70.08 -31.76 Average
5 0.272 37.73 10.18 47.91 79.07 -31.16 QP
6 0.272 35.42 10.18 45.60 69.07 -23.47 Average
7 0.549 23.31 10.10 33.41 74.00 -40.59 QP
8 0.549 20.18 10.10 30.28 64.00 -33.72 Average
9 1.000 25.67 10.06 35.73 74.00 -38.27 QP
10 1.000 19.07 10.06 29.13 64.00 -34.87 Average
11 1.403 25.13 10.06 35.19 74.00 -38.81 QP
12 1.403 19.13 10.06 29.19 64.00 -34.81 Average
13 2.001 26.65 10.06 36.71 74.00 -37.29 QP
14 2.001 21.11 10.06 31.17 64.00 -32.83 Average
15 2.869 41.18 10.05 51.23 74.00 -22.77 QP
16 2.869 36.07 10.05 46.12 64.00 -17.88 Average
17 3.509 31.11 10.05 41.16 74.00 -32.84 QP
18 3.509 24.25 10.05 34.30 64.00 -29.70 Average
19 5.993 26.10 10.01 36.11 74.00 -37.89 QP
20 5.993 20.28 10.01 30.29 64.00 -33.71 Average
21 10.019 26.65 10.08 36.73 74.00 -37.27 QP
22 10.019 20.51 10.08 30.59 64.00 -33.41 Average
23 19.532 32.89 10.16 43.05 74.00 -30.95 QP
24 19.532 28.59 10.16 38.75 64.00 -25.25 Average
25 21.035 35.90 10.16 46.06 74.00 -27.94 QP
26 21.035 31.32 10.16 41.48 64.00 -22.52 Average
27 21.946 39.36 10.17 49.53 74.00 -24.47 QP
28 21.946 32.75 10.17 42.92 64.00 -21.08 Average
29 23.018 35.05 10.17 45.22 74.00 -28.78 QP
30 23.018 30.54 10.17 40.71 64.00 -23.29 Average
31 25.727 35.26 10.17 45.43 74.00 -28.57 QP
32 25.727 29.78 10.17 39.95 64.00 -24.05 Average
33 30.000 29.60 10.19 39.79 74.00 -34.21 QP
34 30.000 22.69 10.19 32.88 64.00 -31.12 Average

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 26 of 46
Control Terminal Disturbance Voltage Test Data
CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: ISN
RATING: 110Vac / 60Hz TEMP/HUM: 25.7C / 70%
COMMENT: Test Mode: LED Mode (LM 20%) (HLG-80H-12B) (110V) (With Common choke)
Data:201 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-10

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV dBuV dB

1 0.160 38.43 10.30 48.73 83.47 -34.74 QP


2 0.160 31.33 10.30 41.63 73.47 -31.84 Average
3 0.232 41.10 10.20 51.30 80.39 -29.09 QP
4 0.232 38.53 10.20 48.73 70.39 -21.66 Average
5 0.267 40.64 10.18 50.82 79.20 -28.38 QP
6 0.267 37.60 10.18 47.78 69.20 -21.42 Average
7 0.408 35.53 10.12 45.65 75.68 -30.03 QP
8 0.408 30.37 10.12 40.49 65.68 -25.19 Average
9 0.549 30.92 10.10 41.02 74.00 -32.98 QP
10 0.549 28.20 10.10 38.30 64.00 -25.70 Average
11 1.000 24.77 10.06 34.83 74.00 -39.17 QP
12 1.000 20.33 10.06 30.39 64.00 -33.61 Average
13 1.403 24.35 10.06 34.41 74.00 -39.59 QP
14 1.403 20.37 10.06 30.43 64.00 -33.57 Average
15 2.001 28.97 10.06 39.03 74.00 -34.97 QP
16 2.001 21.23 10.06 31.29 64.00 -32.71 Average
17 2.721 41.00 10.05 51.05 74.00 -22.95 QP
18 2.721 33.28 10.05 43.33 64.00 -20.67 Average
19 2.854 48.95 10.05 59.00 74.00 -15.00 QP
20 2.854 41.66 10.05 51.71 64.00 -12.29 Average
21 3.509 27.07 10.05 37.12 74.00 -36.88 QP
22 3.509 23.43 10.05 33.48 64.00 -30.52 Average
23 5.993 22.70 10.01 32.71 74.00 -41.29 QP
24 5.993 19.56 10.01 29.57 64.00 -34.43 Average
25 10.019 22.91 10.08 32.99 74.00 -41.01 QP
26 10.019 18.67 10.08 28.75 64.00 -35.25 Average
27 21.946 33.36 10.17 43.53 74.00 -30.47 QP
28 21.946 24.81 10.17 34.98 64.00 -29.02 Average
29 25.591 34.40 10.17 44.57 74.00 -29.43 QP
30 25.591 27.78 10.17 37.95 64.00 -26.05 Average
31 30.000 28.60 10.19 38.79 74.00 -35.21 QP
32 30.000 22.77 10.19 32.96 64.00 -31.04 Average

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 27 of 46
4 Radiated Disturbance (9 kHz to 30 MHz) Measurement

4.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

EMI Test Receiver Rohde & Schwarz ESCS 30 100127 2015/10/20

RF Cable HARBOUR RG58/U CBL48 2016/07/27

Triple Loop antenna Schaffner HLA6120 -- 2016/07/07


Note: The above equipments are within the valid calibration period.

4.2 Block Diagram of Test Configuration

Triple Loop antenna

EMI Test 50 cm
Receiver
RF Cable

4.3 Radiated Electromagnetic Disturbance Limit


Limits for loop diameter
Frequency
dB (A)
(MHz)
2m
0.009 - 0.07 88
0.07 - 0.15 88 to 58
0.15 - 3.0 58 to 22
3.0 - 30 22

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 28 of 46

4.4 Instrument Configuration


4.4.1 Set the EMI test receiver frequency range from 9 kHz to 30 MHz.
4.4.2 Set the EMI test receiver bandwidth at 200 Hz, 9 kHz.

4.5 Configuration of Measurement


4.5.1 The reference ground plane shall extend at least 0,5m beyond the boundaries of the
luminaire and have minimum dimensions of 2 x 2 m.
4.5.2 The EUT was placed on a non-conductive table center of the Triple Loop Antenna.

4.6 Test Result


PASS.
The final test data is shown as following pages.

Factor = Cable Loss


Level = Reading + Factor
Margin = Level - Limit

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 29 of 46

Radiated Disturbance Measurement Data


CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Loop 1
RATING: 230Vac / 50Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (230V)

Data:143 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuA dB dBuA dBuA dB

1 0.391 35.51 0.22 35.73 46.48 -10.75 QP


2 0.471 35.52 0.22 35.74 44.24 -8.50 QP
3 0.592 31.71 0.22 31.93 41.51 -9.58 QP
4 0.657 35.10 0.22 35.32 40.24 -4.92 QP
5 0.707 34.32 0.22 34.54 39.37 -4.83 QP
6 0.895 24.63 0.22 24.85 36.54 -11.69 QP

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 30 of 46

Radiated Disturbance Measurement Data


CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Loop 2
RATING: 230Vac / 50Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (230V)

Data:142 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuA dB dBuA dBuA dB

1 0.471 26.20 0.22 26.42 44.24 -17.82 QP


2 0.511 26.21 0.22 26.43 43.26 -16.83 QP
3 0.541 25.25 0.22 25.47 42.58 -17.11 QP
4 0.582 25.33 0.22 25.55 41.70 -16.15 QP
5 0.657 24.70 0.22 24.92 40.24 -15.32 QP
6 0.719 24.68 0.22 24.90 39.17 -14.27 QP

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 31 of 46

Radiated Disturbance Measurement Data


CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Loop 3
RATING: 230Vac / 50Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (230V)

Data:141 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuA dB dBuA dBuA dB

1 0.453 25.91 0.22 26.13 44.73 -18.60 QP


2 0.606 26.36 0.22 26.58 41.22 -14.64 QP
3 0.652 26.09 0.22 26.31 40.34 -14.03 QP
4 0.713 24.90 0.22 25.12 39.27 -14.15 QP
5 0.767 19.05 0.22 19.27 38.39 -19.12 QP
6 0.917 14.97 0.22 15.19 36.25 -21.06 QP

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 32 of 46

Radiated Disturbance Measurement Data


CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Loop 1
RATING: 110Vac / 60Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (110V)

Data:138 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuA dB dBuA dBuA dB

1 0.471 36.02 0.22 36.24 44.24 -8.00 QP


2 0.606 35.40 0.22 35.62 41.22 -5.60 QP
3 0.668 36.67 0.22 36.89 40.05 -3.16 QP
4 0.707 35.36 0.22 35.58 39.37 -3.79 QP
5 0.761 30.02 0.22 30.24 38.49 -8.25 QP
6 0.924 26.45 0.22 26.67 36.15 -9.48 QP

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 33 of 46

Radiated Disturbance Measurement Data


CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Loop 2
RATING: 110Vac / 60Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (110V)

Data:139 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuA dB dBuA dBuA dB

1 0.475 23.20 0.22 23.42 44.14 -20.72 QP


2 0.503 25.39 0.22 25.61 43.46 -17.85 QP
3 0.554 26.80 0.22 27.02 42.29 -15.27 QP
4 0.668 26.27 0.22 26.49 40.05 -13.56 QP
5 0.719 26.17 0.22 26.39 39.17 -12.78 QP
6 0.924 15.63 0.22 15.85 36.15 -20.30 QP

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 34 of 46

Radiated Disturbance Measurement Data


CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR: Vic
EUT: Switching Power Supply TEST SITE: Conducted 1
MODEL: HLG-80H-12B POLARIZATION: Loop 3
RATING: 110Vac / 60Hz TEMP/HUM: 25.5C / 54%
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (110V)

Data:140 J:\E3_28\2015\MEAN WELL 2.EM8 2015-08-14

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuA dB dBuA dBuA dB

1 0.582 26.17 0.22 26.39 41.70 -15.31 QP


2 0.647 29.34 0.22 29.56 40.44 -10.88 QP
3 0.707 27.97 0.22 28.19 39.37 -11.18 QP
4 0.749 25.81 0.22 26.03 38.68 -12.65 QP
5 0.895 17.97 0.22 18.19 36.54 -18.35 QP
6 0.963 15.87 0.22 16.09 35.66 -19.57 QP

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 35 of 46

5 Radiated Disturbance (30 MHz to 300 MHz) Measurement

5.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

EMI Test Receiver Rohde & Schwarz ESVS10 826148/011 2015/10/29

Biconical Antenna Schwarzbeck VHA 9103 & BBA 9106 VHA 9103-2418 2016/07/05

Log Antenna Schwarzbeck UHALP 9108-A 9108-A 0739 2016/07/19

Pre-Amplifier Agilent 8447D 2944A09703 2016/04/28

RF Cable EMCI EMC8D-NM-NM-25000 140105 2016/02/15

RF Cable Mini-Circuits CBL-3FL-NMNM CBL56 2015/08/29

RF Cable Insulated Wire CBL59 CBL59 2016/01/21


Note: The above equipments are within the valid calibration period.

5.2 Block Diagram of Test Configuration

10 m

RF Cable

4m

Test table EUT

1m 80 cm
Pre-Amplifier Turntable

EMI Test Receiver Ground Plane

5.3 Radiated Limits


Frequency range Quasi-Peak
(MHz) dB(V /m)
30 - 230 30.0
230 - 300 37.0

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 36 of 46

5.4 Instrument Configuration


5.4.1 Set the EMI test receiver frequency range from 30 MHz to 300 MHz.
5.4.2 Set the EMI test receiver bandwidth at 120 kHz.
5.4.3 Set the EMI test receiver detector as Quasi-Peak (Q.P.).

5.5 Configuration of Measurement


5.5.1 The EUT was placed on a non-conductive table whose total height equaled 80cm. The
turntable can rotate 360 degree to determine the position of the maximum emission level.
5.5.2 The EUT was set 10 meters away from the receiving antenna that was mounted on a
non-conductive mast. The antenna can move up and down between 1 to 4 meters to find out
the maximum emission level.
5.5.3 The initial testing identified the frequency that has the highest disturbance relative to the
limit while operating the EUT in typical modes of operation and cable positions in a test
setup representative of typical system configuration.
5.5.4 The identification of the frequency of highest emission with respect to the limit was found by
investigating emissions at a number of significant frequencies. The probable frequency of
maximum emission had been found and that the associated cable and EUT configuration
and mode of operation had been identified.

5.6 Test Result


PASS.
The final test data is shown as following pages.

Factor = Antenna Factor + Cable Loss - Preamplifier Gain


Level = Reading + Factor
Margin = Level - Limit

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 37 of 46

Radiated Emission Measurement Data


CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR : Ceres
EUT: Switching Power Supply TEST SITE : OATS 1
MODEL: HLG-80H-12B TEST DISTANCE : 10 m
RATING: 230Vac / 50Hz POLARIZATION : HORIZONTAL
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (230V) TEMP/HUM : 23.3 / 62%

Data:615 C:\e3\2015\MEAN WELL.EM8 2015-08-06

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV/m dBuV/m dB

1 59.580 36.30 -22.66 13.64 30.00 -16.36 QP


2 108.590 36.30 -18.82 17.48 30.00 -12.52 QP
3 164.980 35.29 -14.70 20.59 30.00 -9.41 QP
4 184.560 36.30 -13.86 22.44 30.00 -7.56 QP
5 198.650 35.30 -13.53 21.77 30.00 -8.23 QP
6 216.250 34.10 -13.10 21.00 30.00 -9.00 QP

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 38 of 46

Radiated Emission Measurement Data


CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR : Ceres
EUT: Switching Power Supply TEST SITE : OATS 1
MODEL: HLG-80H-12B TEST DISTANCE : 10 m
RATING: 230Vac / 50Hz POLARIZATION : VERTICAL
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (230V) TEMP/HUM : 23.3 / 62%

Data:614 C:\e3\2015\MEAN WELL.EM8 2015-08-06

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV/m dBuV/m dB

1 65.230 41.00 -23.63 17.37 30.00 -12.63 QP


2 108.690 36.51 -18.81 17.70 30.00 -12.30 QP
3 164.980 35.19 -14.70 20.49 30.00 -9.51 QP
4 184.560 33.20 -13.86 19.34 30.00 -10.66 QP
5 216.560 35.20 -13.09 22.11 30.00 -7.89 QP
6 228.980 34.20 -12.42 21.78 30.00 -8.22 QP

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 39 of 46

Radiated Emission Measurement Data


CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR : Ceres
EUT: Switching Power Supply TEST SITE : OATS 1
MODEL: HLG-80H-12B TEST DISTANCE : 10 m
RATING: 110Vac / 60Hz POLARIZATION : HORIZONTAL
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (110V) TEMP/HUM : 23.3 / 62%

Data:616 C:\e3\2015\MEAN WELL.EM8 2015-08-06

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV/m dBuV/m dB

1 65.980 36.20 -23.75 12.45 30.00 -17.55 QP


2 108.980 35.10 -18.75 16.35 30.00 -13.65 QP
3 164.880 34.10 -14.71 19.39 30.00 -10.61 QP
4 184.330 35.20 -13.87 21.33 30.00 -8.67 QP
5 214.560 34.20 -13.12 21.08 30.00 -8.92 QP
6 221.560 35.21 -12.94 22.27 30.00 -7.73 QP

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 40 of 46

Radiated Emission Measurement Data


CLIENT: MEAN WELL ENTERPRISES CO., LTD. OPERATOR : Ceres
EUT: Switching Power Supply TEST SITE : OATS 1
MODEL: HLG-80H-12B TEST DISTANCE : 10 m
RATING: 110Vac / 60Hz POLARIZATION : VERTICAL
COMMENT: Test Mode: LED Mode (LM 100%) (HLG-80H-12B) (110V) TEMP/HUM : 23.3 / 62%

Data:613 C:\e3\2015\MEAN WELL.EM8 2015-08-06

Item Freq. Reading Factor Level Limit Margin Remark


Mark MHz dBuV dB dBuV/m dBuV/m dB

1 64.710 47.30 -23.54 23.76 30.00 -6.24 QP


2 108.550 36.51 -18.83 17.68 30.00 -12.32 QP
3 164.980 35.59 -14.70 20.89 30.00 -9.11 QP
4 184.950 33.20 -13.84 19.36 30.00 -10.64 QP
5 198.650 33.30 -13.53 19.77 30.00 -10.23 QP
6 216.230 35.10 -13.10 22.00 30.00 -8.00 QP

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 41 of 46

6 Performance Criterion of Immunity Test

6.1 EN 61547
Criterion Description
A During the test no change of the luminous intensity shall be observed and the
regulating control, if any, shall operate during the test as intended.

B During the test the luminous intensity may change to any value. After the test the
luminous intensity shall be restored to its initial value within 1 min.
Regulating controls need not function during the test, but after the test the mode of
the control shall be the same as before the test provided that during the test no mode
changing commands were given.

C During and after the test any change of the luminous intensity is allowed and the
lamp(s) may be extinguished. After the test, within 30 min, all functions shall return
to normal if necessary by temporary interruption of the mains supply and / or
operation the regulating control.
Additional requirement for lighting equipment incorporation a starting device:
After the test the lighting equipment is switched off. After half an hour it is switched
on again. The lighting equipment shall start and operate as intended.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 42 of 46

7 Electrical Fast Transient/Burst Immunity Test (EN 61000-4-4)

7.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

EMC Test System EMC PARTNER TRANSIENT-2000 812 2015/09/16


Note: The above equipments are within the valid calibration period.

7.2 Block Diagram of Test Configuration


For Power Ports.

EUT
EMC Test System
Ground Plane
10cm

Insulation support

Grounding cable

Metal Ground Plane Bounding

7.3 Test Levels


Open circuit output test voltage and repetition rate of the impulses
On I/O (input/output) signal, data
On power port, PE
and control ports
Level
Voltage peak Repetition rate Voltage peak Repetition rate
kV kHz kV kHz
1 0,5 5 or 100 0,25 5 or 100
2 1 5 or 100 0,5 5 or 100
3 2 5 or 100 1 5 or 100
4 4 5 or 100 2 5 or 100
a
X Special Special Special Special
NOTE 1: Use of 5 kHz repetition rates is traditional; however, 100 kHz is closer to reality.
Product committees should determine which frequencies are relevant for specific products or
product types.
NOTE 2: With some products, there may be no clear distinction between power ports and I/O
ports, in which case it is up to product committees to make this determination for test
purposes.
a
X is an open level. The level has to be specified in the dedicated equipment specification.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 43 of 46

7.4 Test Requirement


7.4.1 EN 61000-4-4 (EN 61547) require:
5 kHz Repetition frequency
1.0 kV input AC power ports.
1.0 kV output AC power ports.
0.5 kV input DC power ports.
0.5 kV output DC power ports.
0.5 kV Signal and Control ports.
Performance criterion: B

7.5 Configuration of Measurement


7.5.1 The EUT and the auxiliary equipment were placed on a wooden table of 0.8 meters height.
The size of ground plane is greater than 1m1m and project beyond the EUT by at least
0.1m on all sides. The ground plane is connected to the protective earth.
7.5.2 The EUT was connected to the power mains through a coupling device that directly couples
the EFT interference signal. Each of the Line, Loop and Protective Earth (PE) conductors
was impressed with burst noise for 1 minute. Both the voltage polarities were applied for
each test level. The length of the signal and power lines between the coupling device and
the EUT shall be 0,5m 0,05m.

7.6 Test Result


Temperature: 22.0 Humidity: 43 % Atm pres: 986 hPa Test Engineer: Vic

PASS.

7.6.1 The performance criterion after tested EN 61000-4-4 (EN 61547):


Test Mode: LED Mode (LM 100%) (HLG-80H-48A) (230V)
1.0 kV input AC power port: Line
Performance criterion: A B C
1.0 kV input AC power port: Neutral
Performance criterion: A B C
1.0 kV input AC power port: PE
Performance criterion: A B C
1.0 kV input AC power port: Line + Neutral
Performance criterion: A B C
1.0 kV input AC power port: Line + PE
Performance criterion: A B C
1.0 kV input AC power port: Neutral + PE
Performance criterion: A B C
1.0 kV input AC power port: Line + Neutral + PE
Performance criterion: A B C

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 44 of 46

8 Photographs of Test

8.1 Main Terminal & Control Terminal Disturbance Voltage Measurement

Front View

Rear View

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 45 of 46

8.2 Radiated Disturbance (9 kHz to 30 MHz) Measurement

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-02 Page 46 of 46

8.3 Radiated Disturbance (30 MHz to 300 MHz) Measurement

Front View

Rear View

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-01 Page 1 of 5

Test Report

(Declaration of Conformity)

for

Electromagnetic Compliance

of

Product Switching Power Supply


Trade Name MEAN WELL
Model Number HLx-80H-yz
(x=G, N, P; y=12, 15, 20, 24, 30, 36, 42, 48, 54; z=A or B or D or Blank)
HLG-80H-xBL
(x=12, 15, 20, 24, 30, 36, 42, 48, 54)

Prepared for

MEAN WELL ENTERPRISES CO., LTD.


No.28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 248,
Taiwan (R.O.C.)
TEL: +886 2 2299 6100
FAX: +886 2 2299 6200

Prepared by
Interocean EMC Technology Corp.
No.5-2, Lin 1, Tin-Fu Tsun, Lin-Kou Hsiang,
Taipei County 244, Taiwan, R.O.C.
TEL.: +886 2 2600 6861
FAX.: +886 2 2600 6859
Remark:
The test report consists of 5 pages in total. It shall not be reproduced except in full,
without the written approval of IETC. This document may be altered or revised by
IETC only, and shall be noted in the revision section of the document.
The test result in this report is only subjected to the test sample.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-01 Page 2 of 5

Table of Contents

1 General Information 4
1.1 Description of Equipment Under Test 4
1.2 Specifications 5

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-01 Page 3 of 5

Statement of Compliance
Applicant: MEAN WELL ENTERPRISES CO., LTD.
Manufacturer: 1. Mean Well Enterprises Co., Ltd.
2. MEAN WELL (GUANGZHOU) ELECTRONICS CO., LTD.
3. SuZhou Mean Well Technology Co., Ltd.
Product: Switching Power Supply
Model No.: HLx-80H-yz
(x=G, N, P; y=12, 15, 20, 24, 30, 36, 42, 48, 54; z=A or B or D or Blank)
HLG-80H-xBL
(x=12, 15, 20, 24, 30, 36, 42, 48, 54)
Tested Power Supply: 230Vac, 50Hz; 110Vac, 60Hz
Date of Final Test: Dec. 29, 2010
Revision of Report: Rev. 00
Measurement Procedures and Standards Used

Emission: Immunity:
EN 55015: 2006+A1: 2007+A2: 2009 EN 61547: 2009
EN 61000-3-2: 2006+A1: 2009+A2: 2009 EN 61000-4-2: 2009
EN 61000-3-3: 2008 EN 61000-4-3: 2006+A1: 2008+A2: 2010
EN 61000-4-4: 2004+A1: 2010
EN 61000-4-5: 2006
EN 61000-4-6: 2009
EN 61000-4-8: 2010
EN 61000-4-11: 2004

The measurement results in this test report were performed at Interocean EMC Technology
Corp. the responsibility of measurement result is only subjected to the tested sample.
This report shows the EUT is technically compliance with the above official standards.
This report shall not be partial reproduced without written approval by Interocean EMC
Technology Corporation.

Report Issued: 2012/08/16

Project Engineer: Approved:


Victor Chen Benson Tsai

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-01 Page 4 of 5

1 General Information

1.1 Description of Equipment Under Test


Product : Switching Power Supply
Model Number : HLx-80H-yz
(x=G, N, P; y=12, 15, 20, 24, 30, 36, 42, 48, 54; z=A or B or D or Blank)
HLG-80H-xBL
(x=12, 15, 20, 24, 30, 36, 42, 48, 54)
Applicant : MEAN WELL ENTERPRISES CO., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 248,
Taiwan (R.O.C.)
Manufacturer : 1. Mean Well Enterprises Co., Ltd.
No.28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 248,
Taiwan (R.O.C.)
2. MEAN WELL (GUANGZHOU) ELECTRONICS CO., LTD.
2nd Floor, No.A Building, Yuean Ind. Park, Dongpu Town,
TianHe District, Guangzhou City, P.R. China
3. SuZhou Mean Well Technology Co., Ltd.
No. 77, Jian-min Road, Dong-qiao, Pan-yang lnd. Park, Huang-dai Town,
Xiang-cheng District, Suzhou, Jiangsu 215152, P.R. China
Product Information : Input: 100-240Vac, 50/60Hz, 0.85A;
277Vac, 50/60Hz, 0.40A
(277Vac for North America only)
Power Cord: Non-shielded Un-detachable, 0.3m w/o core
Output: The detailed specification, please see Specifications as below.
Power Cable: Non-shielded Un-detachable, 0.3m w/o core
Date of Test : Nov. 26 ~ Dec. 29, 2010 (For 10A112301EL)
Additional Description : (For 10A112301EL)
1.) The Model Number HLG-80H-12A; HLG-80H-15A; HLG-80H-20A;
HLG-80H-24A; HLG-80H-30A; HLG-80H-36A; HLG-80H-42A;
HLG-80H-48A; HLG-80H-54A; HLN-80H-12A; HLN-80H-15A;
HLN-80H-20A; HLN-80H-24A; HLN-80H-30A; HLN-80H-36A;
HLN-80H-42A; HLN-80H-48A; HLN-80H-54A; HLP-80H-48 are
representative selected in the test and included in this report.

(For 10A112301EL-01)
1.) 10A112301EL-01 is a multiple report of 10A112301EL, the differences
are updated the standard and changed the address of Applicant and
Manufacturer (because of municipality change by government).
These modifications are not influence to the previous test result,
therefore, there is no further test necessary in this report.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL-01 Page 5 of 5

1.2 Specifications

Model No. Output


(HLx-80H-yz & HLG-80H-xBL)
Voltage (Vdc) Current (A)

HLx-80H-12z; HLG-80H-12BL 12 5

HLx-80H-15z; HLG-80H-15BL 15 5

HLx-80H-20z; HLG-80H-20BL 20 4

HLx-80H-24z; HLG-80H-24BL 24 3.4

HLx-80H-30z; HLG-80H-30BL 30 2.7

HLx-80H-36z; HLG-80H-36BL 36 2.3

HLx-80H-42z; HLG-80H-42BL 42 1.95

HLx-80H-48z; HLG-80H-48BL 48 1.7

HLx-80H-54z; HLG-80H-54BL 54 1.5


Remark:

1. HLx-80H-yz (x=G stand for metal enclosure with potting compound, N stand
for plastic enclosure without potting compound, P stand for open frame type;
y=12, 15, 20, 24, 30, 36, 42, 48, 54 for output voltage;
z=A or B or D or Blank)

2. HLG-80H-xBL (x=12, 15, 20, 24, 30, 36, 42, 48, 54)

3. Models HLG-80H-xBL (x=12, 15, 20, 24, 30, 36, 42, 48, 54) are identical to
HLx-80H-yz except for the wires termination shall be inside a junction box.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 1 of 385

Test Report

(Declaration of Conformity)

for

Electromagnetic Compliance

of

Product Switching Power Supply


Trade Name MEAN WELL
Model Number HLx-80H-yz
(x=G, N, P; y=12, 15, 20, 24, 30, 36, 42, 48, 54; z=A or B or D or Blank)
HLG-80H-xBL
(x=12, 15, 20, 24, 30, 36, 42, 48, 54)

Prepared for

MEAN WELL ENTERPRISES CO., LTD.


No. 28, Wu-Chuan 3rd Road, Wu Ku Ind. Park,
Taipei Hsien, Taiwan
TEL: +886 2 2299 6100
FAX: +886 2 2299 6200

Prepared by
Interocean EMC Technology Corp.
No.5-2, Lin 1, Tin-Fu Tsun, Lin-Kou Hsiang,
Taipei County 244, Taiwan, R.O.C.
TEL.: +886 2 2600 6861
FAX.: +886 2 2600 6859
Remark:
The test report consists of 385 pages in total. It shall not be reproduced except in
full, without the written approval of IETC. This document may be altered or revised
by IETC only, and shall be noted in the revision section of the document.
The test results in the report only to the tested sample.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 2 of 385

Table of Contents

1 General Information 7
1.1 Description of Equipment Under Test 7
1.2 Specifications 8
1.3 Details of Tested Supporting System 9
1.4 Summary of Test Results 10
1.5 Test Facility 11
1.6 Measurement Uncertainty 12
1.7 Measured Mode 13
1.8 Configuration of EUT Setup 14
1.9 Test Step of EUT (Main Terminal Disturbance Voltage) 15
1.10 Test Step of EUT (Radiated Disturbance (9 kHz to 30 MHz)) 15
1.11 Test Step of EUT (Radiated Disturbance (30 MHz to 300 MHz)) 15

2 Main Terminal Disturbance Voltage Measurement 16


2.1 Instrument 16
2.2 Block Diagram of Test Configuration 16
2.3 Conducted Limit (Power Line) 16
2.4 Instrument Configuration 17
2.5 Configuration of Measurement 17
2.6 Test Result 17

3 Radiated Disturbance (9 kHz to 30 MHz) Measurement 94


3.1 Instrument 94
3.2 Block Diagram of Test Configuration 94
3.3 Radiated Electromagnetic Disturbance Limit 94
3.4 Instrument Configuration 95
3.5 Configuration of Measurement 95
3.6 Test Result 95

4 Radiated Disturbance (30 MHz to 300 MHz) Measurement 210


4.1 Instrument 210
4.2 Block Diagram of Test Configuration 210
4.3 Radiated Limits 210
4.4 Instrument Configuration 211
4.5 Configuration of Measurement 211
4.6 Test Result 211

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 3 of 385

5 Harmonic Current Emission Measurement (EN 61000-3-2) 288


5.1 Instrument 288
5.2 Block Diagram of Test Configuration 288
5.3 Test Limit 289
5.4 Configuration of Measurement 290
5.5 Test Result 290

6 Voltage Fluctuations and Flicker Measurement (EN 61000-3-3) 299


6.1 Instrument 299
6.2 Block Diagram of Test Configuration 299
6.3 Test Limit 299
6.4 Configuration of Measurement 299
6.5 Test Result 299

7 Performance Criterion of Immunity Test 302


7.1 EN 61547 302

8 Electrostatic Discharge Immunity Test (EN 61000-4-2) 303


8.1 Instrument 303
8.2 Block Diagram of Test Configuration 303
8.3 Test Levels 303
8.4 Test Requirement 303
8.5 Configuration of Measurement 304
8.6 Test Result 304

9 Radio-Frequency, Electromagnetic Field Immunity Test (EN 61000-4-3) 305


9.1 Instrument 305
9.2 Block Diagram of Test Configuration 305
9.3 Test Levels 306
9.4 Test Requirement 306
9.5 Configuration of Measurement 306
9.6 Test Result 306

10 Electrical Fast Transient/Burst Immunity Test (EN 61000-4-4) 307


10.1 Instrument 307
10.2 Block Diagram of Test Configuration 307
10.3 Test Levels 307
10.4 Test Requirement 308
10.5 Configuration of Measurement 308
10.6 Test Result 308

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 4 of 385

11 Surge Immunity Test (EN 61000-4-5) 309


11.1 Instrument 309
11.2 Block Diagram of Test Configuration 309
11.3 Test Levels 309
11.4 Test Requirement 309
11.5 Configuration of Measurement 310
11.6 Test Result 310

12 Radio-Frequency, Conducted Disturbances Immunity Test (EN 61000-4-6) 311


12.1 Instrument 311
12.2 Block Diagram of Test Configuration 311
12.3 Test Levels 311
12.4 Test Requirement 312
12.5 Configuration of Measurement 312
12.6 Test Result 312

13 Power Frequency Magnetic Field Immunity Test (EN 61000-4-8) 313


13.1 Instrument 313
13.2 Block Diagram of Test Configuration 313
13.3 Test Levels 313
13.4 Test Requirement 314
13.5 Configuration of Measurement 314
13.6 Test Result 314

14 Voltage Dips, Short Interruptions Immunity Test (EN 61000-4-11) 315


14.1 Instrument 315
14.2 Block Diagram of Test Configuration 315
14.3 Test Levels 315
14.4 Test Requirement 316
14.5 Configuration of Measurement 316
14.6 Test Result 316

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 5 of 385

15 Photographs of Test 317


15.1 Main Terminal Disturbance Voltage Measurement 317
15.2 Radiated Disturbance (9 kHz to 30 MHz) Measurement 318
15.3 Radiated Disturbance (30 MHz to 300 MHz) Measurement 319
15.4 Harmonic Current & Voltage Fluctuations and Flicker Measurement 320
15.5 Electrostatic Discharge Immunity Test (EN 61000-4-2) 320
15.6 Radio-Frequency, Electromagnetic Field Immunity Test (EN 61000-4-3) 321
15.7 Electrical Fast Transient/Burst Immunity Test (EN 61000-4-4) 322
15.8 Surge Immunity Test (EN 61000-4-5) 322
15.9 Radio-Frequency, Conducted Disturbances Immunity Test (EN 61000-4-6) 323
15.10 Power Frequency Magnetic Field Immunity Test (EN 61000-4-8) 323
15.11 Voltage Dips, Short Interruptions Immunity Test (EN 61000-4-11) 324
15.12 Electrostatic Discharge Test Point 325

16 Photographs of EUT 326


16.1 Model No.: HLG-80H-12A 326
16.2 Model No.: HLG-80H-15A 329
16.3 Model No.: HLG-80H-20A 332
16.4 Model No.: HLG-80H-24A 335
16.5 Model No.: HLG-80H-30A 338
16.6 Model No.: HLG-80H-36A 341
16.7 Model No.: HLG-80H-42A 344
16.8 Model No.: HLG-80H-48A 347
16.9 Model No.: HLG-80H-54A 350
16.10 Model No.: HLN-80H-12A 353
16.11 Model No.: HLN-80H-15A 356
16.12 Model No.: HLN-80H-20A 359
16.13 Model No.: HLN-80H-24A 362
16.14 Model No.: HLN-80H-30A 365
16.15 Model No.: HLN-80H-36A 368
16.16 Model No.: HLN-80H-42A 371
16.17 Model No.: HLN-80H-48A 374
16.18 Model No.: HLN-80H-54A 377
16.19 Model No.: HLP-80H-48 380

17 Photographs of PCB 383


17.1 For HLG-80H-yz Series and HLN-80H-yz Series 383
17.2 For HLP-80H-yz Series 385

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 6 of 385

Statement of Compliance
Applicant: MEAN WELL ENTERPRISES CO., LTD.
Manufacturer: 1. Mean Well Enterprises Co., Ltd.
2. MEAN WELL (GUANGZHOU) ELECTRONICS CO., LTD.
3. SuZhou Mean Well Technology Co., Ltd.
Product: Switching Power Supply
Model No.: HLx-80H-yz
(x=G, N, P; y=12, 15, 20, 24, 30, 36, 42, 48, 54; z=A or B or D or Blank)
HLG-80H-xBL
(x=12, 15, 20, 24, 30, 36, 42, 48, 54)
Tested Power Supply: 230Vac, 50Hz; 110Vac, 60Hz
Date of Final Test: Dec. 29, 2010
Revision of Report: Rev. 03
Measurement Procedures and Standards Used

Emission: Immunity:
EN 55015: 2006+A1: 2007+A2: 2009 EN 61547: 2009
EN 61000-3-2: 2006 EN 61000-4-2: 2009
EN 61000-3-3: 2008 EN 61000-4-3: 2006+A1: 2008
EN 61000-4-4: 2004
EN 61000-4-5: 2006
EN 61000-4-6: 2009
EN 61000-4-8: 1993+A1: 2001
EN 61000-4-11: 2004

The measurement results in this test report were performed at Interocean EMC Technology
Corp. the responsibility of measurement result is only subject to the tested sample.
This report shows the EUT is technically compliance with the above official standards.
This report shall not be partial reproduced without written approval by Interocean EMC
Technology Corporation.

Report Issued: 2011/01/19

Project Engineer: Approved:


Victor Chen Benson Tsai

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 7 of 385

1 General Information

1.1 Description of Equipment Under Test


Product : Switching Power Supply
Model Number : HLx-80H-yz
(x=G, N, P; y=12, 15, 20, 24, 30, 36, 42, 48, 54; z=A or B or D or Blank)
HLG-80H-xBL
(x=12, 15, 20, 24, 30, 36, 42, 48, 54)
Applicant : MEAN WELL ENTERPRISES CO., LTD.
No. 28, Wu-Chuan 3rd Road, Wu Ku Ind. Park, Taipei Hsien, Taiwan
Manufacturer : 1. Mean Well Enterprises Co., Ltd.
No. 28, Wu-Chuan 3rd Road, Wu Ku Ind. Park, Taipei Hsien 248, Taiwan
2. MEAN WELL (GUANGZHOU) ELECTRONICS CO., LTD.
A Bldg, 2nd Fl Yuean Industrial Park Dongpu Town, Tianhe
Guangzhou Guangdong 510660 China
3. SuZhou Mean Well Technology Co., Ltd.
No. 77, Jian-min Road, Dong-qiao, Pan-yang lnd. Park, Huang-dai Town,
Xiang-cheng District, Suzhou, Jiangsu 215152, P.R. China
Product Information : Input: 100-240Vac, 50/60Hz, 0.85A;
277Vac, 50/60Hz, 0.40A
(277Vac for North America only)
Power Cord: Non-shielded Un-detachable, 0.3m w/o core
Output: The detailed specification, please see Specifications as below.
Power Cable: Non-shielded Un-detachable, 0.3m w/o core
Date of Test : Nov. 26 ~ Dec. 29, 2010
Additional Description : 1.) The Model Number HLG-80H-12A; HLG-80H-15A; HLG-80H-20A;
HLG-80H-24A; HLG-80H-30A; HLG-80H-36A; HLG-80H-42A;
HLG-80H-48A; HLG-80H-54A; HLN-80H-12A; HLN-80H-15A;
HLN-80H-20A; HLN-80H-24A; HLN-80H-30A; HLN-80H-36A;
HLN-80H-42A; HLN-80H-48A; HLN-80H-54A; HLP-80H-48 are
representative selected in the test and included in this report.
2.) For more detail specification about EUT, please refer to the users
manual.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 8 of 385

1.2 Specifications

Model No. Output


(HLx-80H-yz & HLG-80H-xBL)
Voltage (Vdc) Current (A)

HLx-80H-12z; HLG-80H-12BL 12 5

HLx-80H-15z; HLG-80H-15BL 15 5

HLx-80H-20z; HLG-80H-20BL 20 4

HLx-80H-24z; HLG-80H-24BL 24 3.4

HLx-80H-30z; HLG-80H-30BL 30 2.7

HLx-80H-36z; HLG-80H-36BL 36 2.3

HLx-80H-42z; HLG-80H-42BL 42 1.95

HLx-80H-48z; HLG-80H-48BL 48 1.7

HLx-80H-54z; HLG-80H-54BL 54 1.5


Remark:

1. HLx-80H-yz (x=G stand for metal enclosure with potting compound, N stand
for plastic enclosure without potting compound, P stand for open frame type;
y=12, 15, 20, 24, 30, 36, 42, 48, 54 for output voltage;
z=A or B or D or Blank)

2. HLG-80H-xBL (x=12, 15, 20, 24, 30, 36, 42, 48, 54)

3. Models HLG-80H-xBL (x=12, 15, 20, 24, 30, 36, 42, 48, 54) are identical to
HLx-80H-yz except for the wires termination shall be inside a junction box.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 9 of 385

1.3 Details of Tested Supporting System


1.3.1 LOAD (HLG-80H-12A; HLN-80H-12A)
LED LOAD WATT : 60W (12Vdc, 5A)

1.3.2 LOAD (HLG-80H-15A; HLN-80H-15A)


LED LOAD WATT : 75W (15Vdc, 5A)

1.3.3 LOAD (HLG-80H-20A; HLN-80H-20A)


LED LOAD WATT : 80W (20Vdc, 4A)

1.3.4 LOAD (HLG-80H-24A; HLN-80H-24A)


LED LOAD WATT : 81.6W (24Vdc, 3.4A)

1.3.5 LOAD (HLG-80H-30A; HLN-80H-30A)


LED LOAD WATT : 81W (30Vdc, 2.7A)

1.3.6 LOAD (HLG-80H-36A; HLN-80H-36A)


LED LOAD WATT : 82.8W (36Vdc, 2.3A)

1.3.7 LOAD (HLG-80H-42A; HLN-80H-42A)


LED LOAD WATT : 81.9W (42Vdc, 1.95A)

1.3.8 LOAD (HLG-80H-48A)


LED LOAD WATT : 81.6W (48Vdc, 1.7A)
60% LED LOAD WATT : 48.96W (48Vdc, 1.02A)

1.3.9 LOAD (HLN-80H-48A; HLP-80H-48)


LED LOAD WATT : 81.6W (48Vdc, 1.7A)

1.3.10 LOAD (HLG-80H-54A; HLN-80H-54A)


LED LOAD WATT : 81W (54Vdc, 1.5A)

1.3.11 Power Cord (For Emission Measurement)


Power Cord : Non-shielded, Detachable, 1.5m, w/o core

1.3.12 Power Cable


Power Cable : Non-shielded, Detachable, 0.7m, w/o core

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 10 of 385

1.4 Summary of Test Results


1.4.1 Test program is according to EN 55015
Report Reference Reference
Phenomenon Application Result
Clause Clause(s) standard
Not
Insertion loss Enclosure port 7 --
applicable
Main Terminal
2 Main Terminal 8 -- PASS
Disturbance Voltage
Load Terminal Not
Load Terminal 8 --
Disturbance Voltage applicable
Control Terminal Not
Control Terminal 8 --
Disturbance Voltage applicable
Radiated disturbance
3 Enclosure port 9 -- PASS
(9 kHz to 30 MHz)
Radiated disturbance
4 Enclosure port 9 CISPR 22 PASS
(30 MHz to 300 MHz)

1.4.2 Test program is according to EN 61000-3-2


Report Reference Reference
Phenomenon Application Result
Clause Clause standard
Harmonic current
5 AC power port 5 -- PASS
emissions

1.4.3 Test program is according to EN 61000-3-3


Report Reference Reference
Phenomenon Application Result
Clause Clause standard
Voltage changes, voltage
6 AC power port 5 -- PASS
fluctuations and flicker

1.4.4 Test program is according to EN 61547


Report Reference Reference
Phenomenon Application Result
Clause Clause(s) standard
Electrostatic discharges
8 Enclosure port 5.2 EN 61000-4-2 PASS
(ESD)
Radio-frequency
9 Enclosure port 5.3 EN 61000-4-3 PASS
electromagnetic fields

10 Fast transients AC power port 5.5 EN 61000-4-4 PASS

11 Surges AC power port 5.7 EN 61000-4-5 PASS

Radio-frequency common
12 AC power port 5.6 EN 61000-4-6 PASS
mode
Power frequency
13 Enclosure port 5.4 EN 61000-4-8 PASS
magnetic fields
Voltage dips and short
14 AC power port 5.8 EN 61000-4-11 PASS
interruptions

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 11 of 385

1.5 Test Facility


Site Description : Conduction 1 OATS 1 EMS Site
Name of Firm : Interocean EMC Technology Corp.
Company web : http://www.ietc.com.tw
Site 1, 2, 3 Location : No.5-2, Lin 1, Tin-Fu Tsun, Lin-Kou Hsiang,
Taipei County, Taiwan, R.O.C.
Site Filing : Federal Communication Commissions USA
Registration No.: 96399 (OATS 1 & 2)
Registration No.: 518958 (OATS 3)
Designation No.: TW1020
Voluntary Control Council for Interference by Information
Technology Equipment (VCCI) Japan
Member No.: 1349
Registration No. (Conducted Room): C-1094
Registration No. (Conducted Room): T-1562
Registration No. (OATS 1): R-1040; G-274
Registration No. (OATS 2): R-1041
Industry Canada (IC)
OUR FILE: 46405-4437 Submission: 130946
Registration No. (OATS 1): 4437A-1
Registration No. (OATS 2): 4437A-2
Registration No. (OATS 3): 4437A-3
Site Accreditation : Bureau of Standards and Metrology and Inspection
(BSMI) Taiwan, R.O.C.
Accreditation No.:
SL2-IN-E-0026 for CNS13438 / CISPR22
SL2-R1-E-0026 for CNS13439 / CISPR13
SL2-R2-E-0026 for CNS13439 / CISPR13
SL2-A1-E-0026 for CNS13783-1 / CISPR14-1
SL2-L1-E-0026 for CNS 14115 / CISPR 15
Taiwan Accreditation Foundation (TAF)
Accrditation No.: 1113
TV NORD
Certificate No: TNTW0801R-02

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 12 of 385

1.6 Measurement Uncertainty


Item Value
Conduction 1:
Power Line Conducted Emission (9kHz~30MHz) 2.4 dB
Telecom. Port Conducted Emission / ISN-T4 (150kHz~30MHz) 2.6 dB
Telecom. Port Conducted Emission / ISN-T8 (150kHz~30MHz) 2.6 dB
Telecom. Port Conducted Emission / Current Probe (150kHz~30MHz) 2.8 dB
Radiated Electromagnetic disturbance / Loop Antenna (9kHz~30MHz) 4.8 dB
Conduction 2:
Power Line Conducted Emission (9kHz~30MHz) 2.4 dB
Telecom. Port Conducted Emission / ISN-T4 (150kHz~30MHz) 2.6 dB
Telecom. Port Conducted Emission / ISN-T8 (150kHz~30MHz) 2.6 dB
Telecom. Port Conducted Emission / Current Probe (150kHz~30MHz) 2.8 dB
Disturbance Power Emission (30MHz~300MHz) 3.1 dB
Click disturbances Emission (150kHz~30MHz) 2.4 dB
OATS 1:
Radiated Emission Test (30MHz~1GHz) 4.2 dB
Radiated Emission Test (1GHz~6GHz) 3.2 dB
OATS 2:
Radiated Emission Test (30MHz~1GHz) 4.2 dB
Radiated Emission Test (1GHz~6GHz) 3.2 dB
OATS 3:
Radiated Emission Test (30MHz~1GHz) 4.2 dB
Radiated Emission Test (1GHz~6GHz) 3.2 dB
Conducted Immunity Room:
Conducted Immunity Test / CDN-M2 1.3 dB
Conducted Immunity Test / CDN-M3 1.3 dB
Conducted Immunity Test / EM Clamp 3.2 dB

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 13 of 385

1.7 Measured Mode


1.7.1 The test modes for preliminary test are as following:
Mode 1: LED LOAD (HLG-80H-12A) (230V)
Mode 2: LED LOAD (HLG-80H-15A) (230V)
Mode 3: LED LOAD (HLG-80H-20A) (230V)
Mode 4: LED LOAD (HLG-80H-24A) (230V)
Mode 5: LED LOAD (HLG-80H-30A) (230V)
Mode 6: LED LOAD (HLG-80H-36A) (230V)
Mode 7: LED LOAD (HLG-80H-42A) (230V)
Mode 8: LED LOAD (HLG-80H-48A) (230V)
Mode 9: LED LOAD (HLG-80H-54A) (230V)

Mode 10: LED LOAD (HLN-80H-12A) (230V)


Mode 11: LED LOAD (HLN-80H-15A) (230V)
Mode 12: LED LOAD (HLN-80H-20A) (230V)
Mode 13: LED LOAD (HLN-80H-24A) (230V)
Mode 14: LED LOAD (HLN-80H-30A) (230V)
Mode 15: LED LOAD (HLN-80H-36A) (230V)
Mode 16: LED LOAD (HLN-80H-42A) (230V)
Mode 17: LED LOAD (HLN-80H-48A) (230V)
Mode 18: LED LOAD (HLN-80H-54A) (230V)
Mode 19: LED LOAD (HLP-80H-48) (230V)

Mode 20: LED LOAD (HLG-80H-12A) (110V)


Mode 21: LED LOAD (HLG-80H-15A) (110V)
Mode 22: LED LOAD (HLG-80H-20A) (110V)
Mode 23: LED LOAD (HLG-80H-24A) (110V)
Mode 24: LED LOAD (HLG-80H-30A) (110V)
Mode 25: LED LOAD (HLG-80H-36A) (110V)
Mode 26: LED LOAD (HLG-80H-42A) (110V)
Mode 27: LED LOAD (HLG-80H-48A) (110V)
Mode 28: LED LOAD (HLG-80H-54A) (110V)

Mode 29: LED LOAD (HLN-80H-12A) (110V)


Mode 30: LED LOAD (HLN-80H-15A) (110V)
Mode 31: LED LOAD (HLN-80H-20A) (110V)
Mode 32: LED LOAD (HLN-80H-24A) (110V)
Mode 33: LED LOAD (HLN-80H-30A) (110V)
Mode 34: LED LOAD (HLN-80H-36A) (110V)
Mode 35: LED LOAD (HLN-80H-42A) (110V)
Mode 36: LED LOAD (HLN-80H-48A) (110V)
Mode 37: LED LOAD (HLN-80H-54A) (110V)
Mode 38: LED LOAD (HLP-80H-48) (110V)
Interocean EMC Technology Corp. CE Test Report
Report No.: 10A112301EL Page 14 of 385

1.7.2 For conducted and radiated tests, selected the worst-case modes 1~38 after preliminary
test for final test.
1.7.3 For EN 61000-3-3 and immunity tests, selected the mode 8 for final test.
1.7.4 For EN 61000-3-2 test, the test modes are:
100% LED LOAD (HLG-80H-48A) (230V)
60% LED LOAD (HLG-80H-48A) (230V)

1.8 Configuration of EUT Setup

Connected to mains

Power Cord
A2 1.5m
A1 + A2=max. 1.8m
B1 + B2=1m A1 0.3m
0.7m 0.3m
LED Load B2 B1
EUT
Power Cable

Remark: 1. For Main Terminal Disturbance Voltage Measurement: The length of


power cord is 1.8m long, which shall be as near to 1m as possible,
the excess should be folded at the centre into a bundle no longer
than 0.4m.
2. The length of power cable is 1m long.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 15 of 385

1.9 Test Step of EUT (Main Terminal Disturbance Voltage)


1.9.1 Setup the EUT and peripheral as above.
1.9.2 Turn on the power of the equipment.
1.9.3 Prior to a measurement, the lamp(s) shall be operated until stabilization has been reached.
The following stabilization times shall be observed:
1.9.4 5 min for incandescent lamps;
1.9.5 15 min for fluorescent lamps;
1.9.6 30 min for other discharge lamps;
1.9.7 Measured the Line phase and record value.
1.9.8 Changed into Neutral phase then measured and record value.

1.10 Test Step of EUT (Radiated Disturbance (9 kHz to 30 MHz))


1.10.1 Setup the EUT and peripheral as above.
1.10.2 Turn on the power of the equipment.
1.10.3 Prior to a measurement, the lamp(s) shall be operated until stabilization has been reached.
The following stabilization times shall be observed:
1.10.4 5 min for incandescent lamps;
1.10.5 15 min for fluorescent lamps;
1.10.6 30 min for other discharge lamps;
1.10.7 Measure the LOOP 1 and record the value.
1.10.8 Change into LOOP 2, LOOP 3, then measure and record value.

1.11 Test Step of EUT (Radiated Disturbance (30 MHz to 300 MHz))
1.11.1 Setup the EUT and peripheral as above.
1.11.2 Turn on the power of the equipment.
1.11.3 Executed the test.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 16 of 385

2 Main Terminal Disturbance Voltage Measurement

2.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

EMI Test Receiver Rohde & Schwarz ESCS 30 830245/027 2011/10/05

RF Cable HARBOUR RG400 CBL32 2011/03/15

L.I.S.N. Schwarzbeck NNLK8121 8121417 2012/07/16

L.I.S.N. Rohde & Schwarz ESH3-Z5 100176 2011/02/18


Note: The above equipments are within the valid calibration period.

2.2 Block Diagram of Test Configuration

Rear of EUT to be flush with Non-conductive table


rear of table top 0.1m

EMI Test 0.8 m to


Receiver EUT Peripheral
ground
plane

RF Cable

0.8 m

0.4 m
LISN
LISN

Power Cord
0.4 m to vertical ground
Bonded to horizontal
Bonded to horizontal reference plane
ground plane
ground plane

Vertical ground reference plane

2.3 Conducted Limit (Power Line)


Limits dB (V)
Frequency (MHz)
Q.P. (Quasi-Peak) A.V. (Average)
0.009 ~ 0.05 110 ---
0.05 ~ 0.15 90 to 80 ---
0.15 ~ 0.5 66 to 56 56 to 46
0.5 ~ 5.0 56 46
5.0 ~ 30 60 50

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 17 of 385

2.4 Instrument Configuration


2.4.1 Set the EMI test receiver frequency range from 9kHz to 30 MHz.
2.4.2 Set the EMI test receiver bandwidth at 200Hz, 9kHz.
2.4.3 Set the EMI test receiver detector as Quasi-Peak (Q.P.) and Average (AV).

2.5 Configuration of Measurement


2.5.1 The EUT was placed on a non-conductive table whose total height equaled 80cm and
vertical conducting plane located 40cm to the rear of the EUT.
2.5.2 The EUT was connected to the main power through Line Impedance Stabilization Networks
(LISN). This setup provided a 50ohm / 50H coupling impedance for the measuring
equipment. The auxiliary equipment was also connected to the main power through a LISN
that provided a 50ohm/50H coupling impedance with 50ohm termination. (Refer to the
block diagram of the test setup and photographs.)
2.5.3 The conducted disturbance was measured between the phase lead and the reference
ground, and between the neutral lead and reference ground. The initial testing identified the
frequency that has the highest disturbance relative to the limit while operating the EUT in
typical modes of operation and cable positions in a test setup representative of typical
system configuration.
2.5.4 The identification of the frequency of highest disturbance with respect to the limit was found
by investigating disturbances at a number of significant frequencies. The probable frequency
of maximum disturbance had been found and that the associated cable and EUT
configuration and mode of operation had been identified.
2.5.5 An initial survey or scan of the complete frequency rang 9kHz to 30MHz shall be made with
full light output. In addition, at the following frequencies and at all frequencies at which there
is a maximum disturbance found in the initial survey, the control setting shall be varied for
maximum disturbance while maintaining the maximum load:
2.5.6 9kHz50kHz100kHz160kHz240kHz550kHz1MHz1.4MHz2MHz3.5MHz
6MHz10MHz22MHz30MHz.

2.6 Test Result


PASS.
The final test data is shown as following pages.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 18 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9669
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 64.64 -- 64.68 -- 110.00 -- -45.32 --
0.050 0.04 41.28 -- 41.32 -- 90.00 -- -48.68 --
0.072 0.05 78.70 -- 78.75 -- 86.68 -- -7.93 --
0.099 0.05 50.24 -- 50.29 -- 83.78 -- -33.49 --
0.181 0.14 51.30 45.39 51.44 45.53 64.44 54.44 -13.00 -8.91
0.204 0.14 50.50 44.00 50.64 44.14 63.45 53.45 -12.81 -9.31
0.548 0.14 30.36 22.55 30.50 22.69 56.00 46.00 -25.50 -23.31
1.041 0.15 28.33 21.84 28.48 21.99 56.00 46.00 -27.52 -24.01
1.334 0.14 25.59 20.10 25.73 20.24 56.00 46.00 -30.27 -25.76
2.025 0.12 26.32 19.07 26.44 19.19 56.00 46.00 -29.56 -26.81
3.420 0.10 32.19 26.71 32.29 26.81 56.00 46.00 -23.71 -19.19
6.088 0.25 40.35 35.36 40.60 35.61 60.00 50.00 -19.40 -14.39
10.420 0.49 46.59 41.48 47.08 41.97 60.00 50.00 -12.92 -8.03
14.955 0.70 47.03 41.72 47.73 42.42 60.00 50.00 -12.27 -7.58
22.459 0.94 22.00 17.13 22.94 18.07 60.00 50.00 -37.06 -31.93
29.998 1.14 20.47 15.38 21.61 16.52 60.00 50.00 -38.39 -33.48
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 1: LED LOAD (HLG-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 19 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9668
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 64.46 -- 64.46 -- 110.00 -- -45.54 --
0.050 0.02 41.20 -- 41.22 -- 90.00 -- -48.78 --
0.072 0.03 79.20 -- 79.23 -- 86.68 -- -7.45 --
0.099 0.04 49.17 -- 49.21 -- 83.78 -- -34.57 --
0.150 0.14 57.90 45.23 58.04 45.37 66.00 56.00 -7.96 -10.63
0.204 0.13 55.50 49.30 55.63 49.43 63.45 53.45 -7.82 -4.02
0.244 0.13 50.65 43.00 50.78 43.13 61.96 51.96 -11.18 -8.83
0.564 0.13 24.00 18.50 24.13 18.63 56.00 46.00 -31.87 -27.37
1.033 0.14 27.31 21.24 27.45 21.38 56.00 46.00 -28.55 -24.62
1.435 0.13 18.86 12.27 18.99 12.40 56.00 46.00 -37.01 -33.60
1.939 0.11 26.91 21.73 27.02 21.84 56.00 46.00 -28.98 -24.16
3.443 0.10 31.68 26.12 31.78 26.22 56.00 46.00 -24.22 -19.78
6.005 0.25 39.45 33.73 39.70 33.98 60.00 50.00 -20.30 -16.02
10.197 0.49 46.60 41.34 47.09 41.83 60.00 50.00 -12.91 -8.17
13.861 0.68 47.77 42.65 48.45 43.33 60.00 50.00 -11.55 -6.67
21.896 0.96 25.12 19.90 26.08 20.86 60.00 50.00 -33.92 -29.14
29.490 1.14 21.68 16.60 22.82 17.74 60.00 50.00 -37.18 -32.26
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 1: LED LOAD (HLG-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 20 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9670
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 64.75 -- 64.79 -- 110.00 -- -45.21 --
0.052 0.04 41.58 -- 41.62 -- 89.64 -- -48.02 --
0.099 0.05 47.44 -- 47.49 -- 83.78 -- -36.29 --
0.177 0.14 52.90 46.70 53.04 46.84 64.63 54.63 -11.59 -7.79
0.204 0.14 52.50 45.60 52.64 45.74 63.45 53.45 -10.81 -7.71
0.603 0.14 22.58 15.80 22.72 15.94 56.00 46.00 -33.28 -30.06
0.955 0.15 26.44 16.51 26.59 16.66 56.00 46.00 -29.41 -29.34
1.494 0.14 23.56 14.90 23.70 15.04 56.00 46.00 -32.30 -30.96
2.045 0.12 29.11 18.62 29.23 18.74 56.00 46.00 -26.77 -27.26
3.498 0.10 31.90 26.56 32.00 26.66 56.00 46.00 -24.00 -19.34
5.818 0.24 36.54 30.34 36.78 30.58 60.00 50.00 -23.22 -19.42
9.720 0.45 44.70 39.34 45.15 39.79 60.00 50.00 -14.85 -10.21
11.173 0.52 46.68 41.28 47.20 41.80 60.00 50.00 -12.80 -8.20
22.248 0.93 19.60 14.67 20.53 15.60 60.00 50.00 -39.47 -34.40
29.642 1.14 19.20 14.48 20.34 15.62 60.00 50.00 -39.66 -34.38
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 2: LED LOAD (HLG-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 21 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9671
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 64.64 -- 64.64 -- 110.00 -- -45.36 --
0.050 0.02 40.13 -- 40.15 -- 90.00 -- -49.85 --
0.101 0.04 47.40 -- 47.44 -- 83.60 -- -36.16 --
0.177 0.13 53.28 48.60 53.41 48.73 64.63 54.63 -11.22 -5.90
0.204 0.13 51.00 43.10 51.13 43.23 63.45 53.45 -12.32 -10.22
0.587 0.13 37.29 30.82 37.42 30.95 56.00 46.00 -18.58 -15.05
1.060 0.14 31.19 21.98 31.33 22.12 56.00 46.00 -24.67 -23.88
1.330 0.13 27.97 13.97 28.10 14.10 56.00 46.00 -27.90 -31.90
2.201 0.10 29.99 19.32 30.09 19.42 56.00 46.00 -25.91 -26.58
3.443 0.10 32.93 27.36 33.03 27.46 56.00 46.00 -22.97 -18.54
5.896 0.25 37.19 31.19 37.44 31.44 60.00 50.00 -22.56 -18.56
10.841 0.52 47.21 41.81 47.73 42.33 60.00 50.00 -12.27 -7.67
12.470 0.61 45.99 40.86 46.60 41.47 60.00 50.00 -13.40 -8.53
22.220 0.97 23.32 18.17 24.29 19.14 60.00 50.00 -35.71 -30.86
29.611 1.14 19.10 14.14 20.24 15.28 60.00 50.00 -39.76 -34.72
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 2: LED LOAD (HLG-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 22 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9676
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 64.69 -- 64.73 -- 110.00 -- -45.27 --
0.051 0.04 38.75 -- 38.79 -- 89.82 -- -51.03 --
0.099 0.05 46.94 -- 46.99 -- 83.78 -- -36.79 --
0.154 0.14 59.31 44.20 59.45 44.34 65.78 55.78 -6.33 -11.44
0.166 0.14 57.86 43.65 58.00 43.79 65.16 55.16 -7.16 -11.37
0.184 0.14 54.60 48.20 54.74 48.34 64.30 54.30 -9.56 -5.96
0.248 0.14 44.59 36.98 44.73 37.12 61.82 51.82 -17.09 -14.70
0.556 0.14 33.02 21.80 33.16 21.94 56.00 46.00 -22.84 -24.06
1.037 0.15 28.31 21.09 28.46 21.24 56.00 46.00 -27.54 -24.76
1.537 0.13 27.07 21.80 27.20 21.93 56.00 46.00 -28.80 -24.07
2.166 0.11 31.82 23.69 31.93 23.80 56.00 46.00 -24.07 -22.20
3.353 0.10 34.54 28.63 34.64 28.73 56.00 46.00 -21.36 -17.27
6.068 0.25 38.41 32.37 38.66 32.62 60.00 50.00 -21.34 -17.38
10.287 0.48 47.37 41.88 47.85 42.36 60.00 50.00 -12.15 -7.64
15.572 0.71 47.31 41.94 48.02 42.65 60.00 50.00 -11.98 -7.35
21.865 0.91 18.83 14.37 19.74 15.28 60.00 50.00 -40.26 -34.72
29.564 1.14 18.58 13.61 19.72 14.75 60.00 50.00 -40.28 -35.25
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 3: LED LOAD (HLG-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 23 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9677
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 64.22 -- 64.22 -- 110.00 -- -45.78 --
0.053 0.02 40.03 -- 40.05 -- 89.47 -- -49.42 --
0.101 0.04 47.36 -- 47.40 -- 83.60 -- -36.20 --
0.150 0.14 58.60 41.30 58.74 41.44 66.00 56.00 -7.26 -14.56
0.184 0.13 55.10 49.50 55.23 49.63 64.30 54.30 -9.07 -4.67
0.244 0.13 46.02 39.47 46.15 39.60 61.96 51.96 -15.81 -12.36
0.486 0.13 36.32 32.48 36.45 32.61 56.24 46.24 -19.79 -13.63
0.959 0.14 26.14 15.77 26.28 15.91 56.00 46.00 -29.72 -30.09
1.345 0.13 28.81 20.61 28.94 20.74 56.00 46.00 -27.06 -25.26
2.220 0.10 31.57 22.59 31.67 22.69 56.00 46.00 -24.33 -23.31
3.588 0.11 34.52 28.74 34.63 28.85 56.00 46.00 -21.37 -17.15
6.150 0.26 40.04 33.89 40.30 34.15 60.00 50.00 -19.70 -15.85
9.935 0.48 46.85 41.40 47.33 41.88 60.00 50.00 -12.67 -8.12
13.142 0.64 47.67 42.60 48.31 43.24 60.00 50.00 -11.69 -6.76
15.209 0.74 46.94 41.69 47.68 42.43 60.00 50.00 -12.32 -7.57
22.072 0.97 23.31 18.38 24.28 19.35 60.00 50.00 -35.72 -30.65
29.474 1.14 19.36 14.52 20.50 15.66 60.00 50.00 -39.50 -34.34
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 3: LED LOAD (HLG-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 24 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9688
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 64.53 -- 64.57 -- 110.00 -- -45.43 --
0.050 0.04 38.97 -- 39.01 -- 90.00 -- -50.99 --
0.100 0.05 46.03 -- 46.08 -- 83.69 -- -37.61 --
0.154 0.14 53.59 44.07 53.73 44.21 65.78 55.78 -12.05 -11.57
0.184 0.14 52.00 45.40 52.14 45.54 64.30 54.30 -12.16 -8.76
0.230 0.14 54.30 46.80 54.44 46.94 62.45 52.45 -8.01 -5.51
0.427 0.14 39.12 30.76 39.26 30.90 57.31 47.31 -18.05 -16.41
0.619 0.14 32.29 26.31 32.43 26.45 56.00 46.00 -23.57 -19.55
0.990 0.15 28.38 23.14 28.53 23.29 56.00 46.00 -27.47 -22.71
1.353 0.14 25.46 16.27 25.60 16.41 56.00 46.00 -30.40 -29.59
2.119 0.11 23.73 17.03 23.84 17.14 56.00 46.00 -32.16 -28.86
3.798 0.13 32.08 26.49 32.21 26.62 56.00 46.00 -23.79 -19.38
6.420 0.26 39.12 32.96 39.38 33.22 60.00 50.00 -20.62 -16.78
10.541 0.49 46.13 41.02 46.62 41.51 60.00 50.00 -13.38 -8.49
11.841 0.55 47.29 42.36 47.84 42.91 60.00 50.00 -12.16 -7.09
14.845 0.69 45.75 39.48 46.44 40.17 60.00 50.00 -13.56 -9.83
21.810 0.90 23.61 19.06 24.51 19.96 60.00 50.00 -35.49 -30.04
29.318 1.13 19.43 14.65 20.56 15.78 60.00 50.00 -39.44 -34.22
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 4: LED LOAD (HLG-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 25 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9687
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 64.39 -- 64.39 -- 110.00 -- -45.61 --
0.050 0.02 39.06 -- 39.08 -- 90.00 -- -50.92 --
0.099 0.04 45.42 -- 45.46 -- 83.78 -- -38.32 --
0.166 0.13 51.65 44.41 51.78 44.54 65.16 55.16 -13.38 -10.62
0.186 0.13 51.80 46.40 51.93 46.53 64.21 54.21 -12.28 -7.68
0.228 0.13 54.50 46.10 54.63 46.23 62.52 52.52 -7.89 -6.29
0.427 0.13 38.71 29.83 38.84 29.96 57.31 47.31 -18.47 -17.35
0.564 0.13 27.15 18.26 27.28 18.39 56.00 46.00 -28.72 -27.61
1.064 0.14 21.06 12.78 21.20 12.92 56.00 46.00 -34.80 -33.08
1.384 0.13 17.28 10.44 17.41 10.57 56.00 46.00 -38.59 -35.43
2.103 0.10 26.68 20.44 26.78 20.54 56.00 46.00 -29.22 -25.46
3.482 0.10 30.69 24.69 30.79 24.79 56.00 46.00 -25.21 -21.21
6.670 0.27 39.02 33.31 39.29 33.58 60.00 50.00 -20.71 -16.42
10.861 0.52 46.26 41.09 46.78 41.61 60.00 50.00 -13.22 -8.39
13.087 0.64 47.15 42.30 47.79 42.94 60.00 50.00 -12.21 -7.06
20.576 0.88 25.88 20.99 26.76 21.87 60.00 50.00 -33.24 -28.13
29.650 1.14 20.32 15.48 21.46 16.62 60.00 50.00 -38.54 -33.38
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 4: LED LOAD (HLG-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 26 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9679
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 64.73 -- 64.77 -- 110.00 -- -45.23 --
0.053 0.04 40.49 -- 40.53 -- 89.47 -- -48.94 --
0.100 0.05 48.53 -- 48.58 -- 83.69 -- -35.11 --
0.181 0.14 54.55 48.44 54.69 48.58 64.44 54.44 -9.75 -5.86
0.220 0.14 48.40 39.50 48.54 39.64 62.82 52.82 -14.28 -13.18
0.443 0.14 44.30 29.29 44.44 29.43 57.01 47.01 -12.57 -17.58
0.533 0.14 25.87 16.14 26.01 16.28 56.00 46.00 -29.99 -29.72
0.974 0.15 24.11 17.78 24.26 17.93 56.00 46.00 -31.74 -28.07
1.334 0.14 26.17 14.48 26.31 14.62 56.00 46.00 -29.69 -31.38
2.052 0.12 28.09 22.97 28.21 23.09 56.00 46.00 -27.79 -22.91
3.439 0.10 32.95 26.72 33.05 26.82 56.00 46.00 -22.95 -19.18
6.392 0.26 39.42 33.31 39.68 33.57 60.00 50.00 -20.32 -16.43
9.705 0.45 45.69 40.37 46.14 40.82 60.00 50.00 -13.86 -9.18
14.111 0.66 49.07 43.80 49.73 44.46 60.00 50.00 -10.27 -5.54
21.877 0.91 23.71 17.97 24.62 18.88 60.00 50.00 -35.38 -31.12
29.740 1.14 20.79 15.40 21.93 16.54 60.00 50.00 -38.07 -33.46
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 5: LED LOAD (HLG-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 27 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9678
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 64.60 -- 64.60 -- 110.00 -- -45.40 --
0.050 0.02 40.15 -- 40.17 -- 90.00 -- -49.83 --
0.100 0.04 48.65 -- 48.69 -- 83.69 -- -35.00 --
0.150 0.14 56.00 40.80 56.14 40.94 66.00 56.00 -9.86 -15.06
0.181 0.13 53.90 49.30 54.03 49.43 64.44 54.44 -10.41 -5.01
0.248 0.13 43.13 34.32 43.26 34.45 61.82 51.82 -18.56 -17.37
0.548 0.13 36.03 24.75 36.16 24.88 56.00 46.00 -19.84 -21.12
0.982 0.14 20.87 13.71 21.01 13.85 56.00 46.00 -34.99 -32.15
1.349 0.13 19.68 9.84 19.81 9.97 56.00 46.00 -36.19 -36.03
2.033 0.11 23.18 17.47 23.29 17.58 56.00 46.00 -32.71 -28.42
3.373 0.10 31.30 24.99 31.40 25.09 56.00 46.00 -24.60 -20.91
5.619 0.24 37.38 31.62 37.62 31.86 60.00 50.00 -22.38 -18.14
11.205 0.54 47.33 42.22 47.87 42.76 60.00 50.00 -12.13 -7.24
13.728 0.67 48.36 43.40 49.03 44.07 60.00 50.00 -10.97 -5.93
22.119 0.97 23.92 18.21 24.89 19.18 60.00 50.00 -35.11 -30.82
29.173 1.14 20.87 15.90 22.01 17.04 60.00 50.00 -37.99 -32.96
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 5: LED LOAD (HLG-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 28 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9684
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 64.37 -- 64.41 -- 110.00 -- -45.59 --
0.052 0.04 40.33 -- 40.37 -- 89.64 -- -49.27 --
0.099 0.05 49.23 -- 49.28 -- 83.78 -- -34.50 --
0.150 0.14 61.46 46.94 61.60 47.08 66.00 56.00 -4.40 -8.92
0.178 0.14 57.80 50.00 57.94 50.14 64.58 54.58 -6.64 -4.44
0.230 0.14 49.90 41.30 50.04 41.44 62.45 52.45 -12.41 -11.01
0.416 0.14 44.31 37.19 44.45 37.33 57.53 47.53 -13.08 -10.20
0.533 0.14 35.18 27.09 35.32 27.23 56.00 46.00 -20.68 -18.77
0.947 0.15 33.20 24.78 33.35 24.93 56.00 46.00 -22.65 -21.07
1.482 0.14 31.64 22.71 31.78 22.85 56.00 46.00 -24.22 -23.15
2.091 0.12 31.41 19.40 31.53 19.52 56.00 46.00 -24.47 -26.48
3.517 0.12 33.59 27.82 33.71 27.94 56.00 46.00 -22.29 -18.06
6.134 0.25 40.20 33.24 40.45 33.49 60.00 50.00 -19.55 -16.51
10.357 0.49 47.80 42.82 48.29 43.31 60.00 50.00 -11.71 -6.69
13.037 0.61 49.64 44.67 50.25 45.28 60.00 50.00 -9.75 -4.72
22.017 0.92 22.80 17.99 23.72 18.91 60.00 50.00 -36.28 -31.09
29.400 1.14 18.16 13.45 19.30 14.59 60.00 50.00 -40.70 -35.41
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 6: LED LOAD (HLG-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 29 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9683
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 64.57 -- 64.57 -- 110.00 -- -45.43 --
0.052 0.02 40.12 -- 40.14 -- 89.64 -- -49.50 --
0.101 0.04 49.31 -- 49.35 -- 83.60 -- -34.25 --
0.150 0.14 61.50 46.40 61.64 46.54 66.00 56.00 -4.36 -9.46
0.178 0.13 57.70 49.90 57.83 50.03 64.58 54.58 -6.75 -4.55
0.230 0.13 48.90 40.80 49.03 40.93 62.45 52.45 -13.42 -11.52
0.420 0.13 43.70 36.89 43.83 37.02 57.45 47.45 -13.62 -10.43
0.599 0.13 36.84 29.73 36.97 29.86 56.00 46.00 -19.03 -16.14
0.986 0.14 25.54 15.71 25.68 15.85 56.00 46.00 -30.32 -30.15
1.431 0.13 27.51 20.94 27.64 21.07 56.00 46.00 -28.36 -24.93
1.990 0.11 25.36 18.93 25.47 19.04 56.00 46.00 -30.53 -26.96
3.291 0.09 31.55 26.30 31.64 26.39 56.00 46.00 -24.36 -19.61
5.795 0.25 37.22 30.71 37.47 30.96 60.00 50.00 -22.53 -19.04
12.306 0.60 49.20 44.20 49.80 44.80 60.00 50.00 -10.20 -5.20
21.134 0.91 25.06 20.10 25.97 21.01 60.00 50.00 -34.03 -28.99
28.595 1.14 20.31 15.54 21.45 16.68 60.00 50.00 -38.55 -33.32
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 6: LED LOAD (HLG-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 30 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9651
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 64.55 -- 65.33 -- 110.00 -- -44.67 --
0.050 0.65 38.49 -- 39.14 -- 90.00 -- -50.86 --
0.099 0.49 46.78 -- 47.27 -- 83.78 -- -36.51 --
0.150 0.58 57.60 42.70 58.18 43.28 66.00 56.00 -7.82 -12.72
0.184 0.57 53.40 48.00 53.97 48.57 64.30 54.30 -10.33 -5.73
0.232 0.57 48.61 41.03 49.18 41.60 62.38 52.38 -13.20 -10.78
0.552 0.57 35.21 27.12 35.78 27.69 56.00 46.00 -20.22 -18.31
0.978 0.58 32.89 28.49 33.47 29.07 56.00 46.00 -22.53 -16.93
1.427 0.57 20.78 12.10 21.35 12.67 56.00 46.00 -34.65 -33.33
2.072 0.55 33.71 27.23 34.26 27.78 56.00 46.00 -21.74 -18.22
3.498 0.54 41.03 35.19 41.57 35.73 56.00 46.00 -14.43 -10.27
4.345 0.61 42.74 36.09 43.35 36.70 56.00 46.00 -12.65 -9.30
6.435 0.71 45.06 38.68 45.77 39.39 60.00 50.00 -14.23 -10.61
10.740 0.96 43.75 38.22 44.71 39.18 60.00 50.00 -15.29 -10.82
13.646 1.06 44.59 39.24 45.65 40.30 60.00 50.00 -14.35 -9.70
21.013 1.33 22.44 17.53 23.77 18.86 60.00 50.00 -36.23 -31.14
29.025 1.58 19.21 14.18 20.79 15.76 60.00 50.00 -39.21 -34.24
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 7: LED LOAD (HLG-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 31 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9650
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 64.51 -- 64.55 -- 110.00 -- -45.45 --
0.050 0.04 38.74 -- 38.78 -- 90.00 -- -51.22 --
0.100 0.05 44.65 -- 44.70 -- 83.69 -- -38.99 --
0.185 0.14 53.40 47.60 53.54 47.74 64.26 54.26 -10.72 -6.52
0.244 0.14 45.66 38.06 45.80 38.20 61.96 51.96 -16.16 -13.76
0.615 0.14 37.53 30.67 37.67 30.81 56.00 46.00 -18.33 -15.19
0.982 0.15 32.69 27.99 32.84 28.14 56.00 46.00 -23.16 -17.86
1.478 0.14 30.22 22.07 30.36 22.21 56.00 46.00 -25.64 -23.79
2.146 0.11 36.26 30.14 36.37 30.25 56.00 46.00 -19.63 -15.75
3.548 0.12 39.08 32.10 39.20 32.22 56.00 46.00 -16.80 -13.78
4.584 0.19 42.46 36.36 42.65 36.55 56.00 46.00 -13.35 -9.45
6.224 0.26 46.35 40.09 46.61 40.35 60.00 50.00 -13.39 -9.65
9.959 0.47 43.21 37.49 43.68 37.96 60.00 50.00 -16.32 -12.04
20.947 0.85 22.65 17.98 23.50 18.83 60.00 50.00 -36.50 -31.17
29.834 1.14 19.40 14.53 20.54 15.67 60.00 50.00 -39.46 -34.33
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 7: LED LOAD (HLG-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 32 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/11
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 64.77 -- 64.81 -- 110.00 -- -45.19 --
0.052 0.04 39.46 -- 39.50 -- 89.64 -- -50.14 --
0.098 0.05 50.75 -- 50.80 -- 83.87 -- -33.07 --
0.150 0.14 61.24 45.04 61.38 45.18 66.00 56.00 -4.62 -10.82
0.189 0.14 53.15 48.50 53.29 48.64 64.08 54.08 -10.79 -5.44
0.315 0.14 45.90 41.30 46.04 41.44 59.84 49.84 -13.80 -8.40
0.378 0.14 48.00 43.30 48.14 43.44 58.32 48.32 -10.18 -4.88
0.439 0.14 44.41 40.30 44.55 40.44 57.08 47.08 -12.53 -6.64
0.564 0.14 36.13 30.41 36.27 30.55 56.00 46.00 -19.73 -15.45
0.955 0.15 31.20 24.22 31.35 24.37 56.00 46.00 -24.65 -21.63
1.326 0.14 29.14 21.98 29.28 22.12 56.00 46.00 -26.72 -23.88
2.025 0.12 36.63 18.84 36.75 18.96 56.00 46.00 -19.25 -27.04
3.783 0.13 30.48 23.99 30.61 24.12 56.00 46.00 -25.39 -21.88
6.451 0.26 32.73 26.78 32.99 27.04 60.00 50.00 -27.01 -22.96
10.576 0.50 35.79 30.53 36.29 31.03 60.00 50.00 -23.71 -18.97
14.623 0.68 43.31 35.47 43.99 36.15 60.00 50.00 -16.01 -13.85
21.177 0.86 26.14 21.32 27.00 22.18 60.00 50.00 -33.00 -27.82
29.322 1.13 16.18 12.09 17.31 13.22 60.00 50.00 -42.69 -36.78
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 8: LED LOAD (HLG-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 33 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/10
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 64.81 -- 64.81 -- 110.00 -- -45.19 --
0.053 0.02 39.86 -- 39.88 -- 89.47 -- -49.59 --
0.099 0.04 49.53 -- 49.57 -- 83.78 -- -34.21 --
0.150 0.14 61.40 45.00 61.54 45.14 66.00 56.00 -4.46 -10.86
0.166 0.13 57.67 42.17 57.80 42.30 65.16 55.16 -7.36 -12.86
0.188 0.13 52.80 49.50 52.93 49.63 64.12 54.12 -11.19 -4.49
0.220 0.13 45.00 34.99 45.13 35.12 62.82 52.82 -17.69 -17.70
0.314 0.13 45.80 42.60 45.93 42.73 59.86 49.86 -13.93 -7.13
0.377 0.13 46.00 44.00 46.13 44.13 58.35 48.35 -12.22 -4.22
0.572 0.13 33.11 26.97 33.24 27.10 56.00 46.00 -22.76 -18.90
0.959 0.14 28.83 21.25 28.97 21.39 56.00 46.00 -27.03 -24.61
1.587 0.12 27.78 17.25 27.90 17.37 56.00 46.00 -28.10 -28.63
1.849 0.12 29.63 16.22 29.75 16.34 56.00 46.00 -26.25 -29.66
3.771 0.13 29.73 24.10 29.86 24.23 56.00 46.00 -26.14 -21.77
6.154 0.26 32.11 26.34 32.37 26.60 60.00 50.00 -27.63 -23.40
10.427 0.50 34.95 29.69 35.45 30.19 60.00 50.00 -24.55 -19.81
14.537 0.72 43.02 35.27 43.74 35.99 60.00 50.00 -16.26 -14.01
22.045 0.96 25.05 20.19 26.01 21.15 60.00 50.00 -33.99 -28.85
28.853 1.14 16.57 12.36 17.71 13.50 60.00 50.00 -42.29 -36.50
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 8: LED LOAD (HLG-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 34 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9659
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 64.73 -- 65.51 -- 110.00 -- -44.49 --
0.050 0.65 40.35 -- 41.00 -- 90.00 -- -49.00 --
0.067 0.60 80.80 -- 81.40 -- 87.34 -- -5.94 --
0.102 0.49 47.60 -- 48.09 -- 83.51 -- -35.42 --
0.150 0.58 57.10 44.70 57.68 45.28 66.00 56.00 -8.32 -10.72
0.181 0.57 50.04 41.98 50.61 42.55 64.44 54.44 -13.83 -11.89
0.228 0.57 51.60 43.50 52.17 44.07 62.52 52.52 -10.35 -8.45
0.568 0.57 40.48 34.24 41.05 34.81 56.00 46.00 -14.95 -11.19
0.943 0.58 35.18 28.79 35.76 29.37 56.00 46.00 -20.24 -16.63
1.384 0.57 35.85 31.60 36.42 32.17 56.00 46.00 -19.58 -13.83
2.138 0.54 38.54 33.05 39.08 33.59 56.00 46.00 -16.92 -12.41
3.716 0.57 39.92 33.52 40.49 34.09 56.00 46.00 -15.51 -11.91
4.673 0.63 41.42 35.55 42.05 36.18 56.00 46.00 -13.95 -9.82
6.345 0.71 42.16 36.01 42.87 36.72 60.00 50.00 -17.13 -13.28
10.080 0.93 40.27 34.73 41.20 35.66 60.00 50.00 -18.80 -14.34
15.216 1.12 47.73 43.00 48.85 44.12 60.00 50.00 -11.15 -5.88
21.310 1.35 22.93 17.87 24.28 19.22 60.00 50.00 -35.72 -30.78
29.705 1.59 20.21 15.03 21.80 16.62 60.00 50.00 -38.20 -33.38
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 9: LED LOAD (HLG-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 35 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9658
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 64.71 -- 64.75 -- 110.00 -- -45.25 --
0.051 0.04 41.32 -- 41.36 -- 89.82 -- -48.46 --
0.067 0.05 78.60 -- 78.65 -- 87.34 -- -8.69 --
0.099 0.05 49.50 -- 49.55 -- 83.78 -- -34.23 --
0.150 0.14 57.30 42.30 57.44 42.44 66.00 56.00 -8.56 -13.56
0.190 0.14 55.00 48.00 55.14 48.14 64.04 54.04 -8.90 -5.90
0.232 0.14 47.89 40.60 48.03 40.74 62.38 52.38 -14.35 -11.64
0.505 0.14 37.45 31.17 37.59 31.31 56.00 46.00 -18.41 -14.69
0.947 0.15 36.55 30.59 36.70 30.74 56.00 46.00 -19.30 -15.26
1.455 0.14 35.93 29.82 36.07 29.96 56.00 46.00 -19.93 -16.04
1.974 0.12 34.88 26.88 35.00 27.00 56.00 46.00 -21.00 -19.00
3.681 0.12 39.14 33.51 39.26 33.63 56.00 46.00 -16.74 -12.37
5.752 0.24 41.54 35.11 41.78 35.35 60.00 50.00 -18.22 -14.65
10.564 0.50 39.36 33.84 39.86 34.34 60.00 50.00 -20.14 -15.66
14.638 0.68 46.93 42.00 47.61 42.68 60.00 50.00 -12.39 -7.32
21.978 0.91 20.72 15.69 21.63 16.60 60.00 50.00 -38.37 -33.40
29.029 1.13 20.33 15.01 21.46 16.14 60.00 50.00 -38.54 -33.86
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 9: LED LOAD (HLG-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 36 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8859
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 64.76 -- 64.83 -- 110.00 -- -45.17 --
0.049 0.04 40.38 -- 40.42 -- 110.00 -- -69.58 --
0.070 0.03 78.60 -- 78.63 -- 86.94 -- -8.31 --
0.100 0.01 49.41 -- 49.42 -- 83.69 -- -34.27 --
0.162 0.11 57.32 37.88 57.43 37.99 65.36 55.36 -7.93 -17.37
0.185 0.11 53.98 34.59 54.09 34.70 64.26 54.26 -10.17 -19.56
0.240 0.11 39.67 26.30 39.78 26.41 62.10 52.10 -22.32 -25.69
0.392 0.11 42.46 24.16 42.57 24.27 58.02 48.02 -15.45 -23.75
0.545 0.11 27.19 15.02 27.30 15.13 56.00 46.00 -28.70 -30.87
0.998 0.11 29.69 19.13 29.80 19.24 56.00 46.00 -26.20 -26.76
1.388 0.09 30.37 22.89 30.46 22.98 56.00 46.00 -25.54 -23.02
2.021 0.07 30.80 25.42 30.87 25.49 56.00 46.00 -25.13 -20.51
3.490 0.06 39.54 33.70 39.60 33.76 56.00 46.00 -16.40 -12.24
4.154 0.12 46.30 40.56 46.42 40.68 56.00 46.00 -9.58 -5.32
6.013 0.22 46.39 41.04 46.61 41.26 60.00 50.00 -13.39 -8.74
9.978 0.46 35.87 29.87 36.33 30.33 60.00 50.00 -23.67 -19.67
22.021 0.98 24.00 18.88 24.98 19.86 60.00 50.00 -35.02 -30.14
29.439 1.21 22.75 17.97 23.96 19.18 60.00 50.00 -36.04 -30.82
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 10: LED LOAD (HLN-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 37 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8860
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 64.76 -- 65.54 -- 110.00 -- -44.46 --
0.050 0.65 41.19 -- 41.84 -- 90.00 -- -48.16 --
0.070 0.59 76.90 -- 77.49 -- 86.94 -- -9.45 --
0.099 0.49 48.50 -- 48.99 -- 83.78 -- -34.79 --
0.162 0.58 57.32 37.88 57.90 38.46 65.36 55.36 -7.46 -16.90
0.177 0.57 54.33 41.17 54.90 41.74 64.63 54.63 -9.73 -12.89
0.244 0.57 38.06 27.38 38.63 27.95 61.96 51.96 -23.33 -24.01
0.548 0.57 22.67 13.42 23.24 13.99 56.00 46.00 -32.76 -32.01
0.998 0.58 30.29 22.44 30.87 23.02 56.00 46.00 -25.13 -22.98
1.380 0.57 30.61 25.89 31.18 26.46 56.00 46.00 -24.82 -19.54
2.017 0.55 30.76 26.03 31.31 26.58 56.00 46.00 -24.69 -19.42
2.920 0.51 42.37 36.78 42.88 37.29 56.00 46.00 -13.12 -8.71
3.552 0.55 41.23 35.55 41.78 36.10 56.00 46.00 -14.22 -9.90
6.021 0.70 46.27 41.19 46.97 41.89 60.00 50.00 -13.03 -8.11
10.045 0.93 35.22 29.19 36.15 30.12 60.00 50.00 -23.85 -19.88
21.830 1.37 23.60 18.66 24.97 20.03 60.00 50.00 -35.03 -29.97
29.947 1.60 22.30 17.46 23.90 19.06 60.00 50.00 -36.10 -30.94
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 10: LED LOAD (HLN-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 38 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8863
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 70.60 -- 70.67 -- 110.00 -- -39.33 --
0.050 0.04 41.39 -- 41.43 -- 90.00 -- -48.57 --
0.101 0.01 45.32 -- 45.33 -- 83.60 -- -38.27 --
0.162 0.11 53.55 48.88 53.66 48.99 65.36 55.36 -11.70 -6.37
0.244 0.11 41.05 31.47 41.16 31.58 61.96 51.96 -20.80 -20.38
0.420 0.11 41.87 30.01 41.98 30.12 57.45 47.45 -15.47 -17.33
0.548 0.11 36.44 32.25 36.55 32.36 56.00 46.00 -19.45 -13.64
0.998 0.11 36.64 30.53 36.75 30.64 56.00 46.00 -19.25 -15.36
1.380 0.09 30.63 23.51 30.72 23.60 56.00 46.00 -25.28 -22.40
1.982 0.07 32.80 26.61 32.87 26.68 56.00 46.00 -23.13 -19.32
3.455 0.06 42.55 36.67 42.61 36.73 56.00 46.00 -13.39 -9.27
4.490 0.14 45.17 39.43 45.31 39.57 56.00 46.00 -10.69 -6.43
5.923 0.22 42.41 36.85 42.63 37.07 60.00 50.00 -17.37 -12.93
9.974 0.46 37.39 32.21 37.85 32.67 60.00 50.00 -22.15 -17.33
22.068 0.98 28.92 23.89 29.90 24.87 60.00 50.00 -30.10 -25.13
29.537 1.21 21.82 17.07 23.03 18.28 60.00 50.00 -36.97 -31.72
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 11: LED LOAD (HLN-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 39 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8864
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 68.80 -- 69.58 -- 110.00 -- -40.42 --
0.049 0.65 41.49 -- 42.14 -- 110.00 -- -67.86 --
0.071 0.58 75.20 -- 75.78 -- 86.81 -- -11.03 --
0.101 0.49 46.70 -- 47.19 -- 83.60 -- -36.41 --
0.162 0.58 51.86 46.54 52.44 47.12 65.36 55.36 -12.92 -8.24
0.244 0.57 39.87 31.18 40.44 31.75 61.96 51.96 -21.52 -20.21
0.334 0.57 42.93 37.27 43.50 37.84 59.35 49.35 -15.85 -11.51
0.548 0.57 37.51 31.66 38.08 32.23 56.00 46.00 -17.92 -13.77
1.002 0.58 37.22 30.89 37.80 31.47 56.00 46.00 -18.20 -14.53
1.388 0.57 33.43 27.33 34.00 27.90 56.00 46.00 -22.00 -18.10
2.005 0.55 34.84 28.72 35.39 29.27 56.00 46.00 -20.61 -16.73
3.537 0.55 42.76 37.41 43.31 37.96 56.00 46.00 -12.69 -8.04
4.960 0.66 45.61 40.35 46.27 41.01 56.00 46.00 -9.73 -4.99
5.966 0.70 42.06 36.57 42.76 37.27 60.00 50.00 -17.24 -12.73
9.923 0.93 37.49 32.21 38.42 33.14 60.00 50.00 -21.58 -16.86
22.029 1.38 27.94 22.96 29.32 24.34 60.00 50.00 -30.68 -25.66
29.486 1.59 22.23 17.51 23.82 19.10 60.00 50.00 -36.18 -30.90
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 11: LED LOAD (HLN-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 40 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8868
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 72.00 -- 72.07 -- 110.00 -- -37.93 --
0.049 0.04 39.11 -- 39.15 -- 110.00 -- -70.85 --
0.101 0.01 44.67 -- 44.68 -- 83.60 -- -38.92 --
0.150 0.11 52.80 36.60 52.91 36.71 66.00 56.00 -13.09 -19.29
0.240 0.11 39.04 29.34 39.15 29.45 62.10 52.10 -22.95 -22.65
0.545 0.11 29.43 16.33 29.54 16.44 56.00 46.00 -26.46 -29.56
0.701 0.11 42.99 39.59 43.10 39.70 56.00 46.00 -12.90 -6.30
0.986 0.11 40.93 37.61 41.04 37.72 56.00 46.00 -14.96 -8.28
1.388 0.09 30.25 22.22 30.34 22.31 56.00 46.00 -25.66 -23.69
2.002 0.07 30.60 24.05 30.67 24.12 56.00 46.00 -25.33 -21.88
3.494 0.06 40.51 33.63 40.57 33.69 56.00 46.00 -15.43 -12.31
4.533 0.15 43.80 37.12 43.95 37.27 56.00 46.00 -12.05 -8.73
5.939 0.22 41.96 36.04 42.18 36.26 60.00 50.00 -17.82 -13.74
10.013 0.46 38.65 33.42 39.11 33.88 60.00 50.00 -20.89 -16.12
21.908 0.97 18.11 12.91 19.08 13.88 60.00 50.00 -40.92 -36.12
29.627 1.22 20.18 15.83 21.40 17.05 60.00 50.00 -38.60 -32.95
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 12: LED LOAD (HLN-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 41 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8867
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 73.40 -- 74.18 -- 110.00 -- -35.82 --
0.049 0.65 38.33 -- 38.98 -- 110.00 -- -71.02 --
0.099 0.49 45.80 -- 46.29 -- 83.78 -- -37.49 --
0.150 0.58 53.11 37.99 53.69 38.57 66.00 56.00 -12.31 -17.43
0.244 0.57 39.22 30.62 39.79 31.19 61.96 51.96 -22.17 -20.77
0.408 0.57 45.03 42.80 45.60 43.37 57.69 47.69 -12.09 -4.32
0.548 0.57 29.61 17.58 30.18 18.15 56.00 46.00 -25.82 -27.85
0.990 0.58 41.39 38.44 41.97 39.02 56.00 46.00 -14.03 -6.98
1.377 0.57 30.91 22.29 31.48 22.86 56.00 46.00 -24.52 -23.14
2.017 0.55 33.48 27.41 34.03 27.96 56.00 46.00 -21.97 -18.04
3.463 0.54 41.13 35.33 41.67 35.87 56.00 46.00 -14.33 -10.13
4.814 0.65 43.30 37.28 43.95 37.93 56.00 46.00 -12.05 -8.07
6.037 0.70 40.13 34.43 40.83 35.13 60.00 50.00 -19.17 -14.87
9.845 0.91 37.75 32.34 38.66 33.25 60.00 50.00 -21.34 -16.75
22.119 1.38 21.73 16.33 23.11 17.71 60.00 50.00 -36.89 -32.29
29.869 1.60 23.19 18.64 24.79 20.24 60.00 50.00 -35.21 -29.76
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 12: LED LOAD (HLN-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 42 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8872
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 68.80 -- 68.87 -- 110.00 -- -41.13 --
0.049 0.04 41.00 -- 41.04 -- 110.00 -- -68.96 --
0.101 0.01 45.26 -- 45.27 -- 83.60 -- -38.33 --
0.162 0.11 52.55 36.24 52.66 36.35 65.36 55.36 -12.70 -19.01
0.170 0.11 51.61 45.09 51.72 45.20 64.96 54.96 -13.24 -9.76
0.244 0.11 38.06 29.09 38.17 29.20 61.96 51.96 -23.79 -22.76
0.408 0.11 43.67 42.27 43.78 42.38 57.69 47.69 -13.91 -5.31
0.552 0.11 36.40 20.58 36.51 20.69 56.00 46.00 -19.49 -25.31
1.002 0.11 36.71 29.67 36.82 29.78 56.00 46.00 -19.18 -16.22
1.392 0.09 32.17 22.44 32.26 22.53 56.00 46.00 -23.74 -23.47
2.017 0.07 33.18 26.52 33.25 26.59 56.00 46.00 -22.75 -19.41
3.548 0.07 39.99 33.93 40.06 34.00 56.00 46.00 -15.94 -12.00
4.834 0.17 46.86 40.43 47.03 40.60 56.00 46.00 -8.97 -5.40
5.955 0.22 45.34 39.26 45.56 39.48 60.00 50.00 -14.44 -10.52
10.056 0.46 37.19 31.66 37.65 32.12 60.00 50.00 -22.35 -17.88
21.744 0.96 19.56 14.34 20.52 15.30 60.00 50.00 -39.48 -34.70
29.388 1.21 20.56 16.03 21.77 17.24 60.00 50.00 -38.23 -32.76
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 13: LED LOAD (HLN-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 43 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8871
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 69.30 -- 70.08 -- 110.00 -- -39.92 --
0.050 0.65 56.60 -- 57.25 -- 90.00 -- -32.75 --
0.101 0.49 47.07 -- 47.56 -- 83.60 -- -36.04 --
0.150 0.58 54.90 38.20 55.48 38.78 66.00 56.00 -10.52 -17.22
0.173 0.58 56.20 48.70 56.78 49.28 64.82 54.82 -8.04 -5.54
0.240 0.57 39.61 30.88 40.18 31.45 62.10 52.10 -21.92 -20.65
0.412 0.57 44.00 42.00 44.57 42.57 57.61 47.61 -13.04 -5.04
0.545 0.57 32.56 16.54 33.13 17.11 56.00 46.00 -22.87 -28.89
1.002 0.58 37.34 30.63 37.92 31.21 56.00 46.00 -18.08 -14.79
1.404 0.57 32.63 26.77 33.20 27.34 56.00 46.00 -22.80 -18.66
1.994 0.55 34.65 28.79 35.20 29.34 56.00 46.00 -20.80 -16.66
3.525 0.55 39.70 33.55 40.25 34.10 56.00 46.00 -15.75 -11.90
4.978 0.66 46.27 39.73 46.93 40.39 56.00 46.00 -9.07 -5.61
5.966 0.70 45.14 38.69 45.84 39.39 60.00 50.00 -14.16 -10.61
9.943 0.93 37.41 31.80 38.34 32.73 60.00 50.00 -21.66 -17.27
21.748 1.36 17.15 12.33 18.51 13.69 60.00 50.00 -41.49 -36.31
28.912 1.58 21.07 16.58 22.65 18.16 60.00 50.00 -37.35 -31.84
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 13: LED LOAD (HLN-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 44 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8876
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 69.34 -- 69.41 -- 110.00 -- -40.59 --
0.050 0.04 43.02 -- 43.06 -- 90.00 -- -46.94 --
0.101 0.01 45.00 -- 45.01 -- 83.60 -- -38.59 --
0.162 0.11 49.89 36.41 50.00 36.52 65.36 55.36 -15.36 -18.84
0.173 0.11 55.36 51.10 55.47 51.21 64.82 54.82 -9.35 -3.61
0.240 0.11 36.60 28.06 36.71 28.17 62.10 52.10 -25.39 -23.93
0.548 0.11 29.57 19.08 29.68 19.19 56.00 46.00 -26.32 -26.81
0.642 0.11 41.31 31.15 41.42 31.26 56.00 46.00 -14.58 -14.74
0.998 0.11 34.08 25.75 34.19 25.86 56.00 46.00 -21.81 -20.14
1.404 0.09 30.40 21.96 30.49 22.05 56.00 46.00 -25.51 -23.95
1.986 0.07 33.72 27.74 33.79 27.81 56.00 46.00 -22.21 -18.19
3.470 0.06 41.76 35.02 41.82 35.08 56.00 46.00 -14.18 -10.92
4.912 0.18 45.58 39.97 45.76 40.15 56.00 46.00 -10.24 -5.85
5.923 0.22 44.18 38.79 44.40 39.01 60.00 50.00 -15.60 -10.99
10.033 0.46 31.73 26.04 32.19 26.50 60.00 50.00 -27.81 -23.50
21.877 0.97 23.26 18.07 24.23 19.04 60.00 50.00 -35.77 -30.96
29.568 1.21 19.51 14.84 20.72 16.05 60.00 50.00 -39.28 -33.95
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 14: LED LOAD (HLN-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 45 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8875
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 68.70 -- 69.48 -- 110.00 -- -40.52 --
0.049 0.65 42.92 -- 43.57 -- 110.00 -- -66.43 --
0.098 0.50 47.19 -- 47.69 -- 83.87 -- -36.18 --
0.162 0.58 48.90 35.72 49.48 36.30 65.36 55.36 -15.88 -19.06
0.173 0.58 55.00 51.20 55.58 51.78 64.82 54.82 -9.24 -3.04
0.240 0.57 38.61 28.94 39.18 29.51 62.10 52.10 -22.92 -22.59
0.404 0.57 45.26 43.35 45.83 43.92 57.77 47.77 -11.94 -3.85
0.548 0.57 28.59 18.79 29.16 19.36 56.00 46.00 -26.84 -26.64
0.998 0.58 35.16 26.92 35.74 27.50 56.00 46.00 -20.26 -18.50
1.408 0.57 31.96 24.76 32.53 25.33 56.00 46.00 -23.47 -20.67
1.998 0.55 36.54 30.50 37.09 31.05 56.00 46.00 -18.91 -14.95
3.521 0.55 43.25 36.90 43.80 37.45 56.00 46.00 -12.20 -8.55
5.474 0.68 45.13 39.06 45.81 39.74 60.00 50.00 -14.19 -10.26
5.970 0.70 43.84 38.07 44.54 38.77 60.00 50.00 -15.46 -11.23
10.002 0.93 30.49 25.33 31.42 26.26 60.00 50.00 -28.58 -23.74
22.021 1.37 21.34 16.45 22.71 17.82 60.00 50.00 -37.29 -32.18
29.423 1.59 19.76 15.25 21.35 16.84 60.00 50.00 -38.65 -33.16
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 14: LED LOAD (HLN-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 46 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8880
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 68.60 -- 69.38 -- 110.00 -- -40.62 --
0.049 0.65 41.35 -- 42.00 -- 110.00 -- -68.00 --
0.100 0.49 42.84 -- 43.33 -- 83.69 -- -40.36 --
0.162 0.58 52.29 47.90 52.87 48.48 65.36 55.36 -12.49 -6.88
0.170 0.58 52.74 49.64 53.32 50.22 64.96 54.96 -11.64 -4.74
0.244 0.57 36.87 28.42 37.44 28.99 61.96 51.96 -24.52 -22.97
0.545 0.57 34.24 25.52 34.81 26.09 56.00 46.00 -21.19 -19.91
0.607 0.57 43.76 38.62 44.33 39.19 56.00 46.00 -11.67 -6.81
0.998 0.58 34.89 27.94 35.47 28.52 56.00 46.00 -20.53 -17.48
1.396 0.57 31.16 22.83 31.73 23.40 56.00 46.00 -24.27 -22.60
1.998 0.55 33.68 28.46 34.23 29.01 56.00 46.00 -21.77 -16.99
3.541 0.55 44.81 37.99 45.36 38.54 56.00 46.00 -10.64 -7.46
5.533 0.68 47.24 41.51 47.92 42.19 60.00 50.00 -12.08 -7.81
5.927 0.69 47.46 41.59 48.15 42.28 60.00 50.00 -11.85 -7.72
10.068 0.93 35.20 29.81 36.13 30.74 60.00 50.00 -23.87 -19.26
22.099 1.38 22.76 17.52 24.14 18.90 60.00 50.00 -35.86 -31.10
29.580 1.59 21.20 16.51 22.79 18.10 60.00 50.00 -37.21 -31.90
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 15: LED LOAD (HLN-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 47 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8879
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 68.10 -- 68.88 -- 110.00 -- -41.12 --
0.050 0.65 42.36 -- 43.01 -- 90.00 -- -46.99 --
0.099 0.49 43.87 -- 44.36 -- 83.78 -- -39.42 --
0.162 0.58 50.52 46.61 51.10 47.19 65.36 55.36 -14.26 -8.17
0.224 0.57 47.23 36.20 47.80 36.77 62.67 52.67 -14.87 -15.90
0.244 0.57 38.35 28.69 38.92 29.26 61.96 51.96 -23.04 -22.70
0.412 0.57 44.61 29.91 45.18 30.48 57.61 47.61 -12.43 -17.13
0.552 0.57 47.30 41.60 47.87 42.17 56.00 46.00 -8.13 -3.83
1.002 0.58 36.57 29.95 37.15 30.53 56.00 46.00 -18.85 -15.47
1.384 0.57 36.38 30.80 36.95 31.37 56.00 46.00 -19.05 -14.63
2.009 0.55 34.11 28.16 34.66 28.71 56.00 46.00 -21.34 -17.29
3.513 0.55 42.79 36.68 43.34 37.23 56.00 46.00 -12.66 -8.77
4.888 0.65 47.72 41.64 48.37 42.29 56.00 46.00 -7.63 -3.71
5.955 0.70 46.88 40.87 47.58 41.57 60.00 50.00 -12.42 -8.43
10.103 0.93 34.57 29.28 35.50 30.21 60.00 50.00 -24.50 -19.79
21.947 1.37 19.64 14.85 21.01 16.22 60.00 50.00 -38.99 -33.78
29.787 1.60 21.05 16.54 22.65 18.14 60.00 50.00 -37.35 -31.86
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 15: LED LOAD (HLN-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 48 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8885
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 68.60 -- 68.67 -- 110.00 -- -41.33 --
0.050 0.04 36.75 -- 36.79 -- 90.00 -- -53.21 --
0.099 0.01 45.00 -- 45.01 -- 83.78 -- -38.77 --
0.158 0.11 47.30 32.66 47.41 32.77 65.57 55.57 -18.16 -22.80
0.162 0.11 46.36 32.22 46.47 32.33 65.36 55.36 -18.89 -23.03
0.240 0.11 34.87 26.41 34.98 26.52 62.10 52.10 -27.12 -25.58
0.408 0.11 44.87 43.21 44.98 43.32 57.69 47.69 -12.71 -4.37
0.545 0.11 38.79 35.00 38.90 35.11 56.00 46.00 -17.10 -10.89
0.998 0.11 33.07 24.21 33.18 24.32 56.00 46.00 -22.82 -21.68
1.377 0.09 28.43 20.30 28.52 20.39 56.00 46.00 -27.48 -25.61
1.982 0.07 40.26 33.27 40.33 33.34 56.00 46.00 -15.67 -12.66
4.505 0.63 51.50 42.20 52.13 42.83 56.00 46.00 -3.87 -3.17
5.459 0.20 51.32 43.37 51.52 43.57 60.00 50.00 -8.48 -6.43
5.982 0.22 53.21 44.53 53.43 44.75 60.00 50.00 -6.57 -5.25
10.052 0.46 39.28 33.42 39.74 33.88 60.00 50.00 -20.26 -16.12
22.037 0.98 29.90 24.61 30.88 25.59 60.00 50.00 -29.12 -24.41
29.420 1.21 17.41 12.57 18.62 13.78 60.00 50.00 -41.38 -36.22
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 16: LED LOAD (HLN-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 49 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8884
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 68.70 -- 69.48 -- 110.00 -- -40.52 --
0.050 0.65 37.76 -- 38.41 -- 90.00 -- -51.59 --
0.099 0.49 44.88 -- 45.37 -- 83.78 -- -38.41 --
0.154 0.58 48.60 36.73 49.18 37.31 65.78 55.78 -16.60 -18.47
0.162 0.58 45.88 32.32 46.46 32.90 65.36 55.36 -18.90 -22.46
0.209 0.57 47.42 40.06 47.99 40.63 63.24 53.24 -15.25 -12.61
0.240 0.57 36.70 27.92 37.27 28.49 62.10 52.10 -24.83 -23.61
0.338 0.57 46.07 40.48 46.64 41.05 59.25 49.25 -12.61 -8.20
0.408 0.57 46.82 44.10 47.39 44.67 57.69 47.69 -10.30 -3.02
0.545 0.57 39.08 35.06 39.65 35.63 56.00 46.00 -16.35 -10.37
0.998 0.58 36.07 26.92 36.65 27.50 56.00 46.00 -19.35 -18.50
1.377 0.57 34.02 24.90 34.59 25.47 56.00 46.00 -21.41 -20.53
1.990 0.55 38.33 29.56 38.88 30.11 56.00 46.00 -17.12 -15.89
3.533 0.55 45.81 38.96 46.36 39.51 56.00 46.00 -9.64 -6.49
4.752 0.65 52.06 42.30 52.71 42.95 56.00 46.00 -3.29 -3.05
5.959 0.70 49.98 43.43 50.68 44.13 60.00 50.00 -9.32 -5.87
10.005 0.93 38.92 32.44 39.85 33.37 60.00 50.00 -20.15 -16.63
22.002 1.37 29.94 24.76 31.31 26.13 60.00 50.00 -28.69 -23.87
29.951 1.60 17.60 13.02 19.20 14.62 60.00 50.00 -40.80 -35.38
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 16: LED LOAD (HLN-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 50 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8889
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 68.50 -- 68.57 -- 110.00 -- -41.43 --
0.049 0.04 41.23 -- 41.27 -- 110.00 -- -68.73 --
0.099 0.01 43.75 -- 43.76 -- 83.78 -- -40.02 --
0.162 0.11 47.22 32.22 47.33 32.33 65.36 55.36 -18.03 -23.03
0.166 0.11 46.41 34.62 46.52 34.73 65.16 55.16 -18.64 -20.43
0.240 0.11 44.50 32.17 44.61 32.28 62.10 52.10 -17.49 -19.82
0.545 0.11 34.71 26.70 34.82 26.81 56.00 46.00 -21.18 -19.19
0.591 0.11 40.61 37.12 40.72 37.23 56.00 46.00 -15.28 -8.77
0.998 0.11 30.59 21.20 30.70 21.31 56.00 46.00 -25.30 -24.69
1.377 0.09 33.82 27.17 33.91 27.26 56.00 46.00 -22.09 -18.74
1.994 0.07 34.39 26.45 34.46 26.52 56.00 46.00 -21.54 -19.48
3.552 0.07 43.12 36.91 43.19 36.98 56.00 46.00 -12.81 -9.02
5.451 0.20 47.70 41.83 47.90 42.03 60.00 50.00 -12.10 -7.97
6.033 0.22 46.99 40.95 47.21 41.17 60.00 50.00 -12.79 -8.83
9.955 0.46 38.35 32.44 38.81 32.90 60.00 50.00 -21.19 -17.10
14.548 0.67 42.69 37.57 43.36 38.24 60.00 50.00 -16.64 -11.76
22.005 0.97 22.82 17.69 23.79 18.66 60.00 50.00 -36.21 -31.34
29.748 1.22 20.65 16.02 21.87 17.24 60.00 50.00 -38.13 -32.76
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 17: LED LOAD (HLN-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 51 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8888
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 68.10 -- 68.88 -- 110.00 -- -41.12 --
0.049 0.65 41.33 -- 41.98 -- 110.00 -- -68.02 --
0.100 0.49 43.87 -- 44.36 -- 83.69 -- -39.33 --
0.162 0.58 47.24 32.66 47.82 33.24 65.36 55.36 -17.54 -22.12
0.177 0.57 51.32 47.22 51.89 47.79 64.63 54.63 -12.74 -6.84
0.240 0.57 45.95 33.15 46.52 33.72 62.10 52.10 -15.58 -18.38
0.533 0.57 40.26 34.79 40.83 35.36 56.00 46.00 -15.17 -10.64
0.545 0.57 36.82 28.53 37.39 29.10 56.00 46.00 -18.61 -16.90
0.998 0.58 31.42 20.56 32.00 21.14 56.00 46.00 -24.00 -24.86
1.412 0.57 36.10 22.16 36.67 22.73 56.00 46.00 -19.33 -23.27
1.990 0.55 34.08 26.70 34.63 27.25 56.00 46.00 -21.37 -18.75
3.486 0.54 42.99 36.06 43.53 36.60 56.00 46.00 -12.47 -9.40
5.955 0.70 46.92 41.07 47.62 41.77 60.00 50.00 -12.38 -8.23
10.119 0.93 36.28 30.62 37.21 31.55 60.00 50.00 -22.79 -18.45
14.505 1.09 42.39 37.01 43.48 38.10 60.00 50.00 -16.52 -11.90
22.087 1.38 20.86 16.19 22.24 17.57 60.00 50.00 -37.76 -32.43
29.810 1.60 21.55 17.04 23.15 18.64 60.00 50.00 -36.85 -31.36
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 17: LED LOAD (HLN-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 52 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8893
Temperature: 24.0 OPERATOR: Owen
Humidity: 58 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 68.60 -- 68.67 -- 110.00 -- -41.33 --
0.049 0.04 41.07 -- 41.11 -- 110.00 -- -68.89 --
0.100 0.01 42.68 -- 42.69 -- 83.69 -- -41.00 --
0.150 0.11 48.20 37.10 48.31 37.21 66.00 56.00 -17.69 -18.79
0.189 0.11 48.23 38.82 48.34 38.93 64.08 54.08 -15.74 -15.15
0.240 0.11 41.90 33.42 42.01 33.53 62.10 52.10 -20.09 -18.57
0.548 0.11 43.82 38.59 43.93 38.70 56.00 46.00 -12.07 -7.30
0.998 0.11 31.66 22.93 31.77 23.04 56.00 46.00 -24.23 -22.96
1.392 0.09 30.06 20.87 30.15 20.96 56.00 46.00 -25.85 -25.04
1.982 0.07 35.35 27.43 35.42 27.50 56.00 46.00 -20.58 -18.50
3.502 0.07 45.24 38.48 45.31 38.55 56.00 46.00 -10.69 -7.45
4.900 0.18 49.20 42.30 49.38 42.48 56.00 46.00 -6.62 -3.52
6.029 0.22 47.64 41.65 47.86 41.87 60.00 50.00 -12.14 -8.13
9.845 0.44 36.07 29.81 36.51 30.25 60.00 50.00 -23.49 -19.75
22.052 0.98 22.67 17.86 23.65 18.84 60.00 50.00 -36.35 -31.16
29.923 1.22 14.95 10.94 16.17 12.16 60.00 50.00 -43.83 -37.84
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 18: LED LOAD (HLN-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 53 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8892
Temperature: 24.0 OPERATOR: Owen
Humidity: 58 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 64.54 -- 65.32 -- 110.00 -- -44.68 --
0.049 0.65 41.00 -- 41.65 -- 110.00 -- -68.35 --
0.100 0.49 43.83 -- 44.32 -- 83.69 -- -39.37 --
0.162 0.58 44.95 33.37 45.53 33.95 65.36 55.36 -19.83 -21.41
0.240 0.57 41.29 31.62 41.86 32.19 62.10 52.10 -20.24 -19.91
0.545 0.57 41.42 33.84 41.99 34.41 56.00 46.00 -14.01 -11.59
0.615 0.57 44.17 41.56 44.74 42.13 56.00 46.00 -11.26 -3.87
0.853 0.58 41.60 36.34 42.18 36.92 56.00 46.00 -13.82 -9.08
1.002 0.58 32.67 23.88 33.25 24.46 56.00 46.00 -22.75 -21.54
1.396 0.57 34.82 27.75 35.39 28.32 56.00 46.00 -20.61 -17.68
2.005 0.55 34.03 26.68 34.58 27.23 56.00 46.00 -21.42 -18.77
3.525 0.55 42.78 36.51 43.33 37.06 56.00 46.00 -12.67 -8.94
3.955 0.58 45.42 39.54 46.00 40.12 56.00 46.00 -10.00 -5.88
5.986 0.70 46.60 40.40 47.30 41.10 60.00 50.00 -12.70 -8.90
9.962 0.93 35.52 29.26 36.45 30.19 60.00 50.00 -23.55 -19.81
21.798 1.37 25.40 20.03 26.77 21.40 60.00 50.00 -33.23 -28.60
29.435 1.59 19.71 14.94 21.30 16.53 60.00 50.00 -38.70 -33.47
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 18: LED LOAD (HLN-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 54 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLP-80H-48 Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/24
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 64.79 -- 64.83 -- 110.00 -- -45.17 --
0.050 0.04 37.69 -- 37.73 -- 90.00 -- -52.27 --
0.099 0.05 49.71 -- 49.76 -- 83.78 -- -34.02 --
0.150 0.14 55.20 41.00 55.34 41.14 66.00 56.00 -10.66 -14.86
0.193 0.14 46.88 38.73 47.02 38.87 63.91 53.91 -16.89 -15.04
0.204 0.14 49.10 43.00 49.24 43.14 63.45 53.45 -14.21 -10.31
0.548 0.14 25.24 19.85 25.38 19.99 56.00 46.00 -30.62 -26.01
1.009 0.15 28.24 23.17 28.39 23.32 56.00 46.00 -27.61 -22.68
1.494 0.14 28.76 23.56 28.90 23.70 56.00 46.00 -27.10 -22.30
2.005 0.12 29.91 22.05 30.03 22.17 56.00 46.00 -25.97 -23.83
3.451 0.10 22.11 16.97 22.21 17.07 56.00 46.00 -33.79 -28.93
6.267 0.26 23.82 19.25 24.08 19.51 60.00 50.00 -35.92 -30.49
9.841 0.46 26.45 21.46 26.91 21.92 60.00 50.00 -33.09 -28.08
14.853 0.69 41.99 35.16 42.68 35.85 60.00 50.00 -17.32 -14.15
23.505 1.01 33.63 28.48 34.64 29.49 60.00 50.00 -25.36 -20.51
27.587 1.12 28.34 23.17 29.46 24.29 60.00 50.00 -30.54 -25.71
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 19: LED LOAD (HLP-80H-48) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 55 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLP-80H-48 Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/25
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 64.55 -- 64.55 -- 110.00 -- -45.45 --
0.050 0.02 37.96 -- 37.98 -- 90.00 -- -52.02 --
0.099 0.04 49.87 -- 49.91 -- 83.78 -- -33.87 --
0.150 0.14 55.40 39.00 55.54 39.14 66.00 56.00 -10.46 -16.86
0.205 0.13 47.49 41.38 47.62 41.51 63.41 53.41 -15.79 -11.90
0.228 0.13 41.32 32.87 41.45 33.00 62.52 52.52 -21.07 -19.52
0.568 0.13 28.76 19.04 28.89 19.17 56.00 46.00 -27.11 -26.83
0.998 0.14 27.42 22.91 27.56 23.05 56.00 46.00 -28.44 -22.95
1.447 0.13 29.10 23.79 29.23 23.92 56.00 46.00 -26.77 -22.08
2.056 0.11 32.11 24.41 32.22 24.52 56.00 46.00 -23.78 -21.48
3.552 0.11 28.88 23.77 28.99 23.88 56.00 46.00 -27.01 -22.12
6.002 0.25 27.67 23.07 27.92 23.32 60.00 50.00 -32.08 -26.68
10.173 0.49 30.15 25.22 30.64 25.71 60.00 50.00 -29.36 -24.29
15.935 0.76 40.59 32.93 41.35 33.69 60.00 50.00 -18.65 -16.31
22.959 1.02 30.26 25.21 31.28 26.23 60.00 50.00 -28.72 -23.77
28.912 1.14 25.30 20.54 26.44 21.68 60.00 50.00 -33.56 -28.32
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 19: LED LOAD (HLP-80H-48) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 56 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9666
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 65.07 -- 65.11 -- 110.00 -- -44.89 --
0.041 0.04 100.80 -- 100.84 -- 110.00 -- -9.16 --
0.050 0.04 86.70 -- 86.74 -- 90.00 -- -3.26 --
0.103 0.06 41.70 -- 41.76 -- 83.42 -- -41.66 --
0.150 0.14 51.20 42.10 51.34 42.24 66.00 56.00 -14.66 -13.76
0.204 0.14 51.20 43.80 51.34 43.94 63.45 53.45 -12.11 -9.51
0.552 0.14 23.30 17.64 23.44 17.78 56.00 46.00 -32.56 -28.22
0.974 0.15 21.93 15.77 22.08 15.92 56.00 46.00 -33.92 -30.08
1.521 0.13 21.44 15.51 21.57 15.64 56.00 46.00 -34.43 -30.36
2.138 0.11 21.33 15.16 21.44 15.27 56.00 46.00 -34.56 -30.73
3.767 0.13 27.51 20.67 27.64 20.80 56.00 46.00 -28.36 -25.20
6.060 0.25 37.13 31.92 37.38 32.17 60.00 50.00 -22.62 -17.83
9.533 0.44 44.69 39.47 45.13 39.91 60.00 50.00 -14.87 -10.09
12.236 0.57 45.59 40.37 46.16 40.94 60.00 50.00 -13.84 -9.06
21.080 0.86 23.59 18.78 24.45 19.64 60.00 50.00 -35.55 -30.36
29.220 1.13 20.91 15.54 22.04 16.67 60.00 50.00 -37.96 -33.33
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 20: LED LOAD (HLG-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 57 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9667
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 64.67 -- 64.67 -- 110.00 -- -45.33 --
0.050 0.02 85.80 -- 85.82 -- 90.00 -- -4.18 --
0.059 0.02 81.50 -- 81.52 -- 88.49 -- -6.97 --
0.101 0.04 50.24 -- 50.28 -- 83.60 -- -33.32 --
0.150 0.14 50.00 41.10 50.14 41.24 66.00 56.00 -15.86 -14.76
0.205 0.13 48.20 41.40 48.33 41.53 63.41 53.41 -15.08 -11.88
0.252 0.13 37.41 34.10 37.54 34.23 61.69 51.69 -24.15 -17.46
0.556 0.13 25.35 20.06 25.48 20.19 56.00 46.00 -30.52 -25.81
0.962 0.14 20.67 15.11 20.81 15.25 56.00 46.00 -35.19 -30.75
1.369 0.13 20.66 15.12 20.79 15.25 56.00 46.00 -35.21 -30.75
1.939 0.11 25.09 18.23 25.20 18.34 56.00 46.00 -30.80 -27.66
4.064 0.14 32.61 26.88 32.75 27.02 56.00 46.00 -23.25 -18.98
6.205 0.26 37.62 32.37 37.88 32.63 60.00 50.00 -22.12 -17.37
9.568 0.45 44.88 39.48 45.33 39.93 60.00 50.00 -14.67 -10.07
11.974 0.58 46.37 41.09 46.95 41.67 60.00 50.00 -13.05 -8.33
13.345 0.65 45.87 40.58 46.52 41.23 60.00 50.00 -13.48 -8.77
14.283 0.70 43.79 38.51 44.49 39.21 60.00 50.00 -15.51 -10.79
20.748 0.89 27.43 22.36 28.32 23.25 60.00 50.00 -31.68 -26.75
29.552 1.14 21.36 16.24 22.50 17.38 60.00 50.00 -37.50 -32.62
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 20: LED LOAD (HLG-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 58 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9673
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 64.73 -- 64.77 -- 110.00 -- -45.23 --
0.050 0.04 84.20 -- 84.24 -- 90.00 -- -5.76 --
0.097 0.05 47.50 -- 47.55 -- 83.97 -- -36.42 --
0.154 0.14 48.99 40.86 49.13 41.00 65.78 55.78 -16.65 -14.78
0.204 0.14 50.50 42.50 50.64 42.64 63.45 53.45 -12.81 -10.81
0.580 0.14 31.88 26.88 32.02 27.02 56.00 46.00 -23.98 -18.98
1.029 0.15 25.03 14.71 25.18 14.86 56.00 46.00 -30.82 -31.14
1.412 0.14 26.99 12.99 27.13 13.13 56.00 46.00 -28.87 -32.87
2.091 0.12 30.06 16.83 30.18 16.95 56.00 46.00 -25.82 -29.05
3.588 0.12 30.30 24.49 30.42 24.61 56.00 46.00 -25.58 -21.39
5.666 0.24 35.74 30.22 35.98 30.46 60.00 50.00 -24.02 -19.54
9.701 0.45 44.00 38.50 44.45 38.95 60.00 50.00 -15.55 -11.05
12.732 0.60 46.85 41.64 47.45 42.24 60.00 50.00 -12.55 -7.76
21.818 0.90 21.03 15.95 21.93 16.85 60.00 50.00 -38.07 -33.15
29.513 1.14 19.98 14.90 21.12 16.04 60.00 50.00 -38.88 -33.96
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 21: LED LOAD (HLG-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 59 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9672
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 64.62 -- 64.62 -- 110.00 -- -45.38 --
0.050 0.02 84.40 -- 84.42 -- 90.00 -- -5.58 --
0.098 0.04 48.07 -- 48.11 -- 83.87 -- -35.76 --
0.170 0.13 46.14 39.49 46.27 39.62 64.96 54.96 -18.69 -15.34
0.204 0.13 52.90 44.30 53.03 44.43 63.45 53.45 -10.42 -9.02
0.584 0.13 33.69 29.40 33.82 29.53 56.00 46.00 -22.18 -16.47
1.025 0.14 28.75 16.83 28.89 16.97 56.00 46.00 -27.11 -29.03
1.408 0.13 24.71 12.49 24.84 12.62 56.00 46.00 -31.16 -33.38
2.002 0.11 32.18 16.95 32.29 17.06 56.00 46.00 -23.71 -28.94
3.642 0.11 29.82 24.24 29.93 24.35 56.00 46.00 -26.07 -21.65
5.654 0.24 36.09 30.53 36.33 30.77 60.00 50.00 -23.67 -19.23
10.802 0.52 47.52 42.36 48.04 42.88 60.00 50.00 -11.96 -7.12
12.439 0.61 47.12 41.84 47.73 42.45 60.00 50.00 -12.27 -7.55
21.752 0.95 22.68 17.34 23.63 18.29 60.00 50.00 -36.37 -31.71
28.904 1.14 22.24 17.34 23.38 18.48 60.00 50.00 -36.62 -31.52
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 21: LED LOAD (HLG-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 60 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9675
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 65.19 -- 65.23 -- 110.00 -- -44.77 --
0.050 0.04 85.60 -- 85.64 -- 90.00 -- -4.36 --
0.103 0.06 38.73 -- 38.79 -- 83.42 -- -44.63 --
0.162 0.14 50.18 41.23 50.32 41.37 65.36 55.36 -15.04 -13.99
0.205 0.14 54.28 46.39 54.42 46.53 63.41 53.41 -8.99 -6.88
0.255 0.14 39.99 35.77 40.13 35.91 61.59 51.59 -21.46 -15.68
0.556 0.14 30.62 24.70 30.76 24.84 56.00 46.00 -25.24 -21.16
1.017 0.15 23.16 15.55 23.31 15.70 56.00 46.00 -32.69 -30.30
1.466 0.14 23.32 16.60 23.46 16.74 56.00 46.00 -32.54 -29.26
2.127 0.11 27.83 18.40 27.94 18.51 56.00 46.00 -28.06 -27.49
3.623 0.12 29.80 23.65 29.92 23.77 56.00 46.00 -26.08 -22.23
6.150 0.25 36.45 30.78 36.70 31.03 60.00 50.00 -23.30 -18.97
10.892 0.51 46.69 41.46 47.20 41.97 60.00 50.00 -12.80 -8.03
23.056 0.98 20.75 15.90 21.73 16.88 60.00 50.00 -38.27 -33.12
29.404 1.14 19.38 14.52 20.52 15.66 60.00 50.00 -39.48 -34.34
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 22: LED LOAD (HLG-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 61 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9674
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 65.01 -- 65.01 -- 110.00 -- -44.99 --
0.050 0.02 85.60 -- 85.62 -- 90.00 -- -4.38 --
0.102 0.04 46.84 -- 46.88 -- 83.51 -- -36.63 --
0.154 0.13 52.27 44.96 52.40 45.09 65.78 55.78 -13.38 -10.69
0.228 0.13 46.16 36.52 46.29 36.65 62.52 52.52 -16.23 -15.87
0.556 0.13 31.05 26.18 31.18 26.31 56.00 46.00 -24.82 -19.69
1.029 0.14 21.10 14.63 21.24 14.77 56.00 46.00 -34.76 -31.23
1.427 0.13 23.60 14.75 23.73 14.88 56.00 46.00 -32.27 -31.12
1.982 0.11 25.37 17.05 25.48 17.16 56.00 46.00 -30.52 -28.84
3.498 0.10 26.55 20.82 26.65 20.92 56.00 46.00 -29.35 -25.08
5.994 0.25 34.36 29.07 34.61 29.32 60.00 50.00 -25.39 -20.68
10.490 0.51 45.87 40.51 46.38 41.02 60.00 50.00 -13.62 -8.98
13.060 0.64 45.65 40.09 46.29 40.73 60.00 50.00 -13.71 -9.27
22.955 1.02 22.72 17.82 23.74 18.84 60.00 50.00 -36.26 -31.16
29.705 1.14 21.07 16.04 22.21 17.18 60.00 50.00 -37.79 -32.82
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 22: LED LOAD (HLG-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 62 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9689
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 65.01 -- 65.05 -- 110.00 -- -44.95 --
0.050 0.04 84.30 -- 84.34 -- 90.00 -- -5.66 --
0.103 0.06 46.63 -- 46.69 -- 83.42 -- -36.73 --
0.152 0.14 53.40 44.10 53.54 44.24 65.89 55.89 -12.35 -11.65
0.204 0.14 52.30 45.20 52.44 45.34 63.45 53.45 -11.01 -8.11
0.552 0.14 29.24 23.70 29.38 23.84 56.00 46.00 -26.62 -22.16
0.966 0.15 24.56 18.09 24.71 18.24 56.00 46.00 -31.29 -27.76
1.353 0.14 15.54 10.25 15.68 10.39 56.00 46.00 -40.32 -35.61
2.048 0.12 19.97 13.59 20.09 13.71 56.00 46.00 -35.91 -32.29
3.580 0.12 28.65 22.33 28.77 22.45 56.00 46.00 -27.23 -23.55
6.080 0.25 34.47 29.00 34.72 29.25 60.00 50.00 -25.28 -20.75
10.826 0.51 47.12 41.87 47.63 42.38 60.00 50.00 -12.37 -7.62
12.173 0.57 47.72 42.48 48.29 43.05 60.00 50.00 -11.71 -6.95
21.716 0.90 24.43 18.54 25.33 19.44 60.00 50.00 -34.67 -30.56
29.158 1.13 19.19 14.47 20.32 15.60 60.00 50.00 -39.68 -34.40
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 23: LED LOAD (HLG-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 63 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9690
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 65.07 -- 65.07 -- 110.00 -- -44.93 --
0.050 0.02 84.20 -- 84.22 -- 90.00 -- -5.78 --
0.100 0.04 46.93 -- 46.97 -- 83.69 -- -36.72 --
0.166 0.13 52.56 45.89 52.69 46.02 65.16 55.16 -12.47 -9.14
0.205 0.13 54.92 48.39 55.05 48.52 63.41 53.41 -8.36 -4.89
0.230 0.13 53.70 44.30 53.83 44.43 62.45 52.45 -8.62 -8.02
0.556 0.13 31.62 26.14 31.75 26.27 56.00 46.00 -24.25 -19.73
0.962 0.14 25.90 19.14 26.04 19.28 56.00 46.00 -29.96 -26.72
1.377 0.13 22.62 11.77 22.75 11.90 56.00 46.00 -33.25 -34.10
2.033 0.11 27.71 15.14 27.82 15.25 56.00 46.00 -28.18 -30.75
3.908 0.14 28.88 23.18 29.02 23.32 56.00 46.00 -26.98 -22.68
5.966 0.25 34.42 28.54 34.67 28.79 60.00 50.00 -25.33 -21.21
10.263 0.49 46.94 41.73 47.43 42.22 60.00 50.00 -12.57 -7.78
12.248 0.60 48.03 42.69 48.63 43.29 60.00 50.00 -11.37 -6.71
21.599 0.94 25.30 19.93 26.24 20.87 60.00 50.00 -33.76 -29.13
29.861 1.14 20.45 15.47 21.59 16.61 60.00 50.00 -38.41 -33.39
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 23: LED LOAD (HLG-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 64 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9681
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 65.15 -- 65.19 -- 110.00 -- -44.81 --
0.050 0.04 84.00 -- 84.04 -- 90.00 -- -5.96 --
0.100 0.05 51.14 -- 51.19 -- 83.69 -- -32.50 --
0.154 0.14 48.81 41.67 48.95 41.81 65.78 55.78 -16.83 -13.97
0.205 0.14 49.16 41.63 49.30 41.77 63.41 53.41 -14.11 -11.64
0.252 0.14 40.12 34.58 40.26 34.72 61.69 51.69 -21.43 -16.97
0.548 0.14 30.84 24.80 30.98 24.94 56.00 46.00 -25.02 -21.06
0.892 0.15 25.08 18.05 25.23 18.20 56.00 46.00 -30.77 -27.80
1.584 0.13 22.14 13.68 22.27 13.81 56.00 46.00 -33.73 -32.19
2.228 0.11 24.65 16.95 24.76 17.06 56.00 46.00 -31.24 -28.94
3.619 0.12 28.97 22.65 29.09 22.77 56.00 46.00 -26.91 -23.23
6.232 0.26 36.38 30.53 36.64 30.79 60.00 50.00 -23.36 -19.21
9.779 0.45 45.93 40.31 46.38 40.76 60.00 50.00 -13.62 -9.24
12.923 0.60 47.60 41.99 48.20 42.59 60.00 50.00 -11.80 -7.41
22.541 0.95 23.73 18.26 24.68 19.21 60.00 50.00 -35.32 -30.79
29.959 1.14 19.63 14.76 20.77 15.90 60.00 50.00 -39.23 -34.10
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 24: LED LOAD (HLG-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 65 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9682
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 64.83 -- 64.83 -- 110.00 -- -45.17 --
0.050 0.02 83.60 -- 83.62 -- 90.00 -- -6.38 --
0.100 0.04 54.30 -- 54.34 -- 83.69 -- -29.35 --
0.170 0.13 44.16 37.45 44.29 37.58 64.96 54.96 -20.67 -17.38
0.193 0.13 48.05 42.73 48.18 42.86 63.91 53.91 -15.73 -11.05
0.248 0.13 43.34 40.48 43.47 40.61 61.82 51.82 -18.35 -11.21
0.545 0.13 32.12 27.26 32.25 27.39 56.00 46.00 -23.75 -18.61
1.017 0.14 18.36 12.00 18.50 12.14 56.00 46.00 -37.50 -33.86
1.486 0.13 20.48 10.88 20.61 11.01 56.00 46.00 -35.39 -34.99
2.123 0.10 26.55 15.51 26.65 15.61 56.00 46.00 -29.35 -30.39
3.759 0.13 30.27 23.96 30.40 24.09 56.00 46.00 -25.60 -21.91
6.115 0.26 36.48 30.60 36.74 30.86 60.00 50.00 -23.26 -19.14
11.189 0.54 48.53 42.80 49.07 43.34 60.00 50.00 -10.93 -6.66
13.443 0.66 48.31 42.73 48.97 43.39 60.00 50.00 -11.03 -6.61
21.857 0.95 24.23 18.24 25.18 19.19 60.00 50.00 -34.82 -30.81
29.568 1.14 21.38 15.84 22.52 16.98 60.00 50.00 -37.48 -33.02
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 24: LED LOAD (HLG-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 66 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9685
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 64.71 -- 64.75 -- 110.00 -- -45.25 --
0.050 0.04 82.50 -- 82.54 -- 90.00 -- -7.46 --
0.098 0.05 48.65 -- 48.70 -- 83.87 -- -35.17 --
0.162 0.14 49.86 42.00 50.00 42.14 65.36 55.36 -15.36 -13.22
0.197 0.14 46.80 41.02 46.94 41.16 63.74 53.74 -16.80 -12.58
0.244 0.14 43.84 38.66 43.98 38.80 61.96 51.96 -17.98 -13.16
0.529 0.14 32.31 27.24 32.45 27.38 56.00 46.00 -23.55 -18.62
0.966 0.15 26.32 16.61 26.47 16.76 56.00 46.00 -29.53 -29.24
1.482 0.14 21.77 15.84 21.91 15.98 56.00 46.00 -34.09 -30.02
2.025 0.12 33.33 17.89 33.45 18.01 56.00 46.00 -22.55 -27.99
3.728 0.13 31.59 25.08 31.72 25.21 56.00 46.00 -24.28 -20.79
6.013 0.25 37.09 31.15 37.34 31.40 60.00 50.00 -22.66 -18.60
9.939 0.47 46.77 41.41 47.24 41.88 60.00 50.00 -12.76 -8.12
11.955 0.56 48.83 43.43 49.39 43.99 60.00 50.00 -10.61 -6.01
13.029 0.61 48.38 42.87 48.99 43.48 60.00 50.00 -11.01 -6.52
24.377 1.06 23.13 17.61 24.19 18.67 60.00 50.00 -35.81 -31.33
29.189 1.13 18.48 13.56 19.61 14.69 60.00 50.00 -40.39 -35.31
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 25: LED LOAD (HLG-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 67 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9686
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 64.97 -- 64.97 -- 110.00 -- -45.03 --
0.050 0.02 83.10 -- 83.12 -- 90.00 -- -6.88 --
0.097 0.04 52.77 -- 52.81 -- 83.97 -- -31.16 --
0.166 0.13 51.97 45.30 52.10 45.43 65.16 55.16 -13.06 -9.73
0.205 0.13 54.58 46.15 54.71 46.28 63.41 53.41 -8.70 -7.13
0.240 0.13 46.79 41.58 46.92 41.71 62.10 52.10 -15.18 -10.39
0.537 0.13 32.01 24.84 32.14 24.97 56.00 46.00 -23.86 -21.03
1.103 0.13 26.56 14.73 26.69 14.86 56.00 46.00 -29.31 -31.14
1.447 0.13 25.99 15.14 26.12 15.27 56.00 46.00 -29.88 -30.73
2.080 0.11 28.60 17.80 28.71 17.91 56.00 46.00 -27.29 -28.09
3.892 0.13 32.03 25.88 32.16 26.01 56.00 46.00 -23.84 -19.99
6.330 0.26 38.20 31.91 38.46 32.17 60.00 50.00 -21.54 -17.83
11.498 0.56 48.85 43.32 49.41 43.88 60.00 50.00 -10.59 -6.12
21.638 0.94 24.28 19.02 25.22 19.96 60.00 50.00 -34.78 -30.04
29.798 1.14 20.19 15.18 21.33 16.32 60.00 50.00 -38.67 -33.68
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 25: LED LOAD (HLG-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 68 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9648
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 64.82 -- 65.60 -- 110.00 -- -44.40 --
0.050 0.65 84.10 -- 84.75 -- 90.00 -- -5.25 --
0.100 0.49 47.14 -- 47.63 -- 83.69 -- -36.06 --
0.150 0.58 52.30 42.10 52.88 42.68 66.00 56.00 -13.12 -13.32
0.189 0.57 44.69 37.77 45.26 38.34 64.08 54.08 -18.82 -15.74
0.248 0.57 34.23 28.66 34.80 29.23 61.82 51.82 -27.02 -22.59
0.564 0.57 27.99 22.07 28.56 22.64 56.00 46.00 -27.44 -23.36
1.068 0.58 24.56 15.11 25.14 15.69 56.00 46.00 -30.86 -30.31
1.470 0.57 23.57 12.72 24.14 13.29 56.00 46.00 -31.86 -32.71
1.990 0.55 28.45 20.41 29.00 20.96 56.00 46.00 -27.00 -25.04
3.548 0.55 33.79 27.63 34.34 28.18 56.00 46.00 -21.66 -17.82
6.697 0.72 43.06 37.60 43.78 38.32 60.00 50.00 -16.22 -11.68
11.150 0.97 48.49 44.10 49.46 45.07 60.00 50.00 -10.54 -4.93
22.587 1.40 20.15 14.77 21.55 16.17 60.00 50.00 -38.45 -33.83
29.283 1.59 19.55 14.46 21.14 16.05 60.00 50.00 -38.86 -33.95
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 26: LED LOAD (HLG-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 69 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9649
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 64.90 -- 64.94 -- 110.00 -- -45.06 --
0.050 0.04 84.60 -- 84.64 -- 90.00 -- -5.36 --
0.100 0.05 49.20 -- 49.25 -- 83.69 -- -34.44 --
0.150 0.14 52.21 42.46 52.35 42.60 66.00 56.00 -13.65 -13.40
0.205 0.14 47.12 41.07 47.26 41.21 63.41 53.41 -16.15 -12.20
0.255 0.14 37.85 33.67 37.99 33.81 61.59 51.59 -23.60 -17.78
0.509 0.14 29.90 21.20 30.04 21.34 56.00 46.00 -25.96 -24.66
0.927 0.15 19.63 12.08 19.78 12.23 56.00 46.00 -36.22 -33.77
1.466 0.14 25.12 15.57 25.26 15.71 56.00 46.00 -30.74 -30.29
1.974 0.12 34.43 21.20 34.55 21.32 56.00 46.00 -21.45 -24.68
3.865 0.13 36.62 30.64 36.75 30.77 56.00 46.00 -19.25 -15.23
6.630 0.27 43.95 38.33 44.22 38.60 60.00 50.00 -15.78 -11.40
10.802 0.51 49.10 44.00 49.61 44.51 60.00 50.00 -10.39 -5.49
22.650 0.95 20.86 15.18 21.81 16.13 60.00 50.00 -38.19 -33.87
29.521 1.14 19.72 14.99 20.86 16.13 60.00 50.00 -39.14 -33.87
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 26: LED LOAD (HLG-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 70 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/13
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 65.13 -- 65.17 -- 110.00 -- -44.83 --
0.050 0.04 83.30 -- 83.34 -- 90.00 -- -6.66 --
0.058 0.05 82.50 -- 82.55 -- 88.65 -- -6.10 --
0.100 0.05 38.46 -- 38.51 -- 83.69 -- -45.18 --
0.158 0.14 48.91 40.60 49.05 40.74 65.57 55.57 -16.52 -14.83
0.204 0.14 51.10 46.80 51.24 46.94 63.45 53.45 -12.21 -6.51
0.255 0.14 45.44 43.33 45.58 43.47 61.59 51.59 -16.01 -8.12
0.416 0.14 40.70 36.60 40.84 36.74 57.53 47.53 -16.69 -10.79
0.556 0.14 34.60 29.11 34.74 29.25 56.00 46.00 -21.26 -16.75
0.923 0.15 31.64 24.44 31.79 24.59 56.00 46.00 -24.21 -21.41
1.576 0.13 25.72 13.57 25.85 13.70 56.00 46.00 -30.15 -32.30
2.088 0.12 25.13 13.03 25.25 13.15 56.00 46.00 -30.75 -32.85
3.681 0.12 26.81 21.29 26.93 21.41 56.00 46.00 -29.07 -24.59
6.361 0.26 32.47 27.55 32.73 27.81 60.00 50.00 -27.27 -22.19
9.939 0.47 37.00 31.67 37.47 32.14 60.00 50.00 -22.53 -17.86
14.263 0.67 41.84 34.40 42.51 35.07 60.00 50.00 -17.49 -14.93
21.337 0.87 26.59 21.51 27.46 22.38 60.00 50.00 -32.54 -27.62
29.502 1.14 16.13 12.05 17.27 13.19 60.00 50.00 -42.73 -36.81
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 27: LED LOAD (HLG-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 71 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/12
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 65.19 -- 65.19 -- 110.00 -- -44.81 --
0.050 0.02 83.60 -- 83.62 -- 90.00 -- -6.38 --
0.062 0.02 79.40 -- 79.42 -- 88.04 -- -8.62 --
0.102 0.04 46.87 -- 46.91 -- 83.51 -- -36.60 --
0.173 0.13 48.08 37.21 48.21 37.34 64.82 54.82 -16.61 -17.48
0.205 0.13 51.07 46.35 51.20 46.48 63.41 53.41 -12.21 -6.93
0.255 0.13 44.18 42.57 44.31 42.70 61.59 51.59 -17.28 -8.89
0.560 0.13 34.84 30.67 34.97 30.80 56.00 46.00 -21.03 -15.20
1.068 0.14 28.65 22.47 28.79 22.61 56.00 46.00 -27.21 -23.39
1.373 0.13 25.03 18.26 25.16 18.39 56.00 46.00 -30.84 -27.61
1.970 0.11 19.04 12.93 19.15 13.04 56.00 46.00 -36.85 -32.96
3.755 0.13 27.66 21.45 27.79 21.58 56.00 46.00 -28.21 -24.42
6.619 0.27 33.73 27.92 34.00 28.19 60.00 50.00 -26.00 -21.81
10.072 0.48 36.25 30.98 36.73 31.46 60.00 50.00 -23.27 -18.54
14.365 0.71 42.51 34.81 43.22 35.52 60.00 50.00 -16.78 -14.48
21.502 0.93 26.01 20.99 26.94 21.92 60.00 50.00 -33.06 -28.08
28.912 1.14 17.62 12.92 18.76 14.06 60.00 50.00 -41.24 -35.94
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 27: LED LOAD (HLG-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 72 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9661
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 65.03 -- 65.81 -- 110.00 -- -44.19 --
0.036 0.70 102.30 -- 103.00 -- 110.00 -- -7.00 --
0.050 0.65 82.70 -- 83.35 -- 90.00 -- -6.65 --
0.100 0.49 51.28 -- 51.77 -- 83.69 -- -31.92 --
0.150 0.58 54.10 43.60 54.68 44.18 66.00 56.00 -11.32 -11.82
0.200 0.57 49.80 46.50 50.37 47.07 63.61 53.61 -13.24 -6.54
0.552 0.57 30.44 23.95 31.01 24.52 56.00 46.00 -24.99 -21.48
1.084 0.58 30.18 22.25 30.76 22.83 56.00 46.00 -25.24 -23.17
1.404 0.57 31.19 22.74 31.76 23.31 56.00 46.00 -24.24 -22.69
2.002 0.55 33.32 26.92 33.87 27.47 56.00 46.00 -22.13 -18.53
3.884 0.57 36.55 30.64 37.12 31.21 56.00 46.00 -18.88 -14.79
6.127 0.70 41.38 36.15 42.08 36.85 60.00 50.00 -17.92 -13.15
9.681 0.90 47.88 43.07 48.78 43.97 60.00 50.00 -11.22 -6.03
11.486 0.98 48.93 44.11 49.91 45.09 60.00 50.00 -10.09 -4.91
21.666 1.36 26.09 21.09 27.45 22.45 60.00 50.00 -32.55 -27.55
29.841 1.60 22.92 18.42 24.52 20.02 60.00 50.00 -35.48 -29.98
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 28: LED LOAD (HLG-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 73 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9660
Temperature: 23.0 OPERATOR: Trevor
Humidity: 35 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 64.97 -- 65.75 -- 110.00 -- -44.25 --
0.036 0.70 101.00 -- 101.70 -- 110.00 -- -8.30 --
0.050 0.65 84.20 -- 84.85 -- 90.00 -- -5.15 --
0.100 0.49 54.20 -- 54.69 -- 83.69 -- -29.00 --
0.150 0.58 53.80 44.00 54.38 44.58 66.00 56.00 -11.62 -11.42
0.201 0.57 49.04 45.61 49.61 46.18 63.57 53.57 -13.96 -7.39
0.248 0.57 41.94 37.03 42.51 37.60 61.82 51.82 -19.31 -14.22
0.548 0.57 33.26 23.07 33.83 23.64 56.00 46.00 -22.17 -22.36
1.091 0.58 29.61 20.84 30.19 21.42 56.00 46.00 -25.81 -24.58
1.400 0.57 30.48 22.68 31.05 23.25 56.00 46.00 -24.95 -22.75
2.134 0.54 35.65 24.29 36.19 24.83 56.00 46.00 -19.81 -21.17
3.685 0.56 35.37 29.71 35.93 30.27 56.00 46.00 -20.07 -15.73
6.396 0.71 41.83 36.64 42.54 37.35 60.00 50.00 -17.46 -12.65
11.048 0.97 49.04 44.40 50.01 45.37 60.00 50.00 -9.99 -4.63
21.599 1.36 26.36 20.52 27.72 21.88 60.00 50.00 -32.28 -28.12
28.271 1.57 20.36 14.44 21.93 16.01 60.00 50.00 -38.07 -33.99
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 28: LED LOAD (HLG-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 74 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8858
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 65.26 -- 65.33 -- 110.00 -- -44.67 --
0.040 0.05 99.90 -- 99.95 -- 110.00 -- -10.05 --
0.050 0.04 85.40 -- 85.44 -- 90.00 -- -4.56 --
0.100 0.01 37.38 -- 37.39 -- 83.69 -- -46.30 --
0.158 0.11 49.59 36.68 49.70 36.79 65.57 55.57 -15.87 -18.78
0.177 0.11 44.30 28.66 44.41 28.77 64.63 54.63 -20.22 -25.86
0.240 0.11 40.58 32.99 40.69 33.10 62.10 52.10 -21.41 -19.00
0.548 0.11 26.29 15.63 26.40 15.74 56.00 46.00 -29.60 -30.26
0.998 0.11 22.13 15.39 22.24 15.50 56.00 46.00 -33.76 -30.50
1.412 0.09 24.62 18.20 24.71 18.29 56.00 46.00 -31.29 -27.71
2.009 0.07 28.62 22.84 28.69 22.91 56.00 46.00 -27.31 -23.09
3.521 0.07 31.82 25.88 31.89 25.95 56.00 46.00 -24.11 -20.05
4.728 0.17 43.83 38.59 44.00 38.76 56.00 46.00 -12.00 -7.24
5.982 0.22 44.95 39.97 45.17 40.19 60.00 50.00 -14.83 -9.81
9.861 0.45 37.61 31.84 38.06 32.29 60.00 50.00 -21.94 -17.71
21.927 0.97 31.73 26.84 32.70 27.81 60.00 50.00 -27.30 -22.19
29.736 1.22 21.27 16.22 22.49 17.44 60.00 50.00 -37.51 -32.56
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 29: LED LOAD (HLN-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 75 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8857
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 65.27 -- 66.05 -- 110.00 -- -43.95 --
0.050 0.65 85.10 -- 85.75 -- 90.00 -- -4.25 --
0.100 0.49 35.95 -- 36.44 -- 83.69 -- -47.25 --
0.162 0.58 47.19 35.48 47.77 36.06 65.36 55.36 -17.59 -19.30
0.177 0.57 43.21 30.00 43.78 30.57 64.63 54.63 -20.85 -24.06
0.240 0.57 39.39 33.31 39.96 33.88 62.10 52.10 -22.14 -18.22
0.545 0.57 22.28 14.12 22.85 14.69 56.00 46.00 -33.15 -31.31
0.998 0.58 24.04 17.44 24.62 18.02 56.00 46.00 -31.38 -27.98
1.392 0.57 27.56 22.03 28.13 22.60 56.00 46.00 -27.87 -23.40
2.005 0.55 27.51 21.30 28.06 21.85 56.00 46.00 -27.94 -24.15
3.447 0.54 32.45 26.14 32.99 26.68 56.00 46.00 -23.01 -19.32
5.998 0.70 42.80 37.87 43.50 38.57 60.00 50.00 -16.50 -11.43
9.947 0.93 35.33 29.83 36.26 30.76 60.00 50.00 -23.74 -19.24
14.189 1.08 42.07 33.40 43.15 34.48 60.00 50.00 -16.85 -15.52
21.947 1.37 33.22 28.52 34.59 29.89 60.00 50.00 -25.41 -20.11
29.412 1.59 24.90 20.05 26.49 21.64 60.00 50.00 -33.51 -28.36
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 29: LED LOAD (HLN-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 76 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8862
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 72.80 -- 72.87 -- 110.00 -- -37.13 --
0.050 0.04 83.90 -- 83.94 -- 90.00 -- -6.06 --
0.099 0.01 33.01 -- 33.02 -- 83.78 -- -50.76 --
0.150 0.11 46.10 36.30 46.21 36.41 66.00 56.00 -19.79 -19.59
0.240 0.11 34.87 26.13 34.98 26.24 62.10 52.10 -27.12 -25.86
0.548 0.11 35.67 30.39 35.78 30.50 56.00 46.00 -20.22 -15.50
0.998 0.11 31.99 26.32 32.10 26.43 56.00 46.00 -23.90 -19.57
1.404 0.09 24.24 19.19 24.33 19.28 56.00 46.00 -31.67 -26.72
2.005 0.07 27.52 21.58 27.59 21.65 56.00 46.00 -28.41 -24.35
3.513 0.07 39.19 33.78 39.26 33.85 56.00 46.00 -16.74 -12.15
5.252 0.19 44.47 39.19 44.66 39.38 60.00 50.00 -15.34 -10.62
5.939 0.22 38.37 32.44 38.59 32.66 60.00 50.00 -21.41 -17.34
10.002 0.46 37.31 32.35 37.77 32.81 60.00 50.00 -22.23 -17.19
12.267 0.56 41.59 36.52 42.15 37.08 60.00 50.00 -17.85 -12.92
22.099 0.98 31.82 26.85 32.80 27.83 60.00 50.00 -27.20 -22.17
29.767 1.22 26.13 20.93 27.35 22.15 60.00 50.00 -32.65 -27.85
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 30: LED LOAD (HLN-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 77 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8861
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 71.36 -- 72.14 -- 110.00 -- -37.86 --
0.050 0.65 84.20 -- 84.85 -- 90.00 -- -5.15 --
0.101 0.49 39.40 -- 39.89 -- 83.60 -- -43.71 --
0.150 0.58 47.00 35.80 47.58 36.38 66.00 56.00 -18.42 -19.62
0.240 0.57 32.60 23.44 33.17 24.01 62.10 52.10 -28.93 -28.09
0.548 0.57 36.56 32.52 37.13 33.09 56.00 46.00 -18.87 -12.91
0.998 0.58 33.09 26.92 33.67 27.50 56.00 46.00 -22.33 -18.50
1.416 0.57 27.36 20.23 27.93 20.80 56.00 46.00 -28.07 -25.20
1.986 0.55 28.71 22.85 29.26 23.40 56.00 46.00 -26.74 -22.60
3.451 0.54 39.87 34.21 40.41 34.75 56.00 46.00 -15.59 -11.25
5.345 0.67 43.63 38.24 44.30 38.91 60.00 50.00 -15.70 -11.09
5.990 0.70 37.44 31.70 38.14 32.40 60.00 50.00 -21.86 -17.60
10.017 0.93 35.83 30.55 36.76 31.48 60.00 50.00 -23.24 -18.52
12.744 1.03 40.15 34.99 41.18 36.02 60.00 50.00 -18.82 -13.98
21.955 1.37 26.47 21.50 27.84 22.87 60.00 50.00 -32.16 -27.13
29.861 1.60 24.33 19.48 25.93 21.08 60.00 50.00 -34.07 -28.92
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 30: LED LOAD (HLN-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 78 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8865
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 71.50 -- 71.57 -- 110.00 -- -38.43 --
0.050 0.04 84.20 -- 84.24 -- 90.00 -- -5.76 --
0.101 0.01 48.50 -- 48.51 -- 83.60 -- -35.09 --
0.150 0.11 47.10 38.30 47.21 38.41 66.00 56.00 -18.79 -17.59
0.240 0.11 33.03 27.23 33.14 27.34 62.10 52.10 -28.96 -24.76
0.545 0.11 29.93 20.97 30.04 21.08 56.00 46.00 -25.96 -24.92
0.584 0.11 38.01 32.76 38.12 32.87 56.00 46.00 -17.88 -13.13
0.998 0.11 28.99 20.95 29.10 21.06 56.00 46.00 -26.90 -24.94
1.408 0.09 25.74 19.38 25.83 19.47 56.00 46.00 -30.17 -26.53
2.021 0.07 26.70 19.56 26.77 19.63 56.00 46.00 -29.23 -26.37
3.525 0.07 35.53 30.18 35.60 30.25 56.00 46.00 -20.40 -15.75
6.060 0.22 35.33 29.74 35.55 29.96 60.00 50.00 -24.45 -20.04
9.900 0.45 38.00 32.69 38.45 33.14 60.00 50.00 -21.55 -16.86
12.181 0.56 41.25 36.18 41.81 36.74 60.00 50.00 -18.19 -13.26
21.716 0.96 26.13 21.48 27.09 22.44 60.00 50.00 -32.91 -27.56
29.697 1.22 19.66 15.30 20.88 16.52 60.00 50.00 -39.12 -33.48
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 31: LED LOAD (HLN-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 79 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8866
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 72.10 -- 72.88 -- 110.00 -- -37.12 --
0.050 0.65 84.70 -- 85.35 -- 90.00 -- -4.65 --
0.097 0.50 51.49 -- 51.99 -- 83.97 -- -31.98 --
0.150 0.58 46.80 38.30 47.38 38.88 66.00 56.00 -18.62 -17.12
0.205 0.57 43.82 35.56 44.39 36.13 63.41 53.41 -19.02 -17.28
0.240 0.57 34.12 25.73 34.69 26.30 62.10 52.10 -27.41 -25.80
0.533 0.57 37.39 33.27 37.96 33.84 56.00 46.00 -18.04 -12.16
0.998 0.58 31.75 24.44 32.33 25.02 56.00 46.00 -23.67 -20.98
1.396 0.57 30.87 24.80 31.44 25.37 56.00 46.00 -24.56 -20.63
2.013 0.55 28.84 22.52 29.39 23.07 56.00 46.00 -26.61 -22.93
3.537 0.55 36.01 30.37 36.56 30.92 56.00 46.00 -19.44 -15.08
6.025 0.70 36.82 31.28 37.52 31.98 60.00 50.00 -22.48 -18.02
9.994 0.93 40.26 34.87 41.19 35.80 60.00 50.00 -18.81 -14.20
12.451 1.02 40.93 35.67 41.95 36.69 60.00 50.00 -18.05 -13.31
22.033 1.38 28.94 24.00 30.32 25.38 60.00 50.00 -29.68 -24.62
29.587 1.59 22.80 17.67 24.39 19.26 60.00 50.00 -35.61 -30.74
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 31: LED LOAD (HLN-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 80 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8869
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 75.10 -- 75.17 -- 110.00 -- -34.83 --
0.050 0.04 84.80 -- 84.84 -- 90.00 -- -5.16 --
0.101 0.01 39.60 -- 39.61 -- 83.60 -- -43.99 --
0.150 0.11 48.10 39.10 48.21 39.21 66.00 56.00 -17.79 -16.79
0.244 0.11 39.04 33.07 39.15 33.18 61.96 51.96 -22.81 -18.78
0.552 0.11 28.03 18.84 28.14 18.95 56.00 46.00 -27.86 -27.05
0.998 0.11 28.99 21.13 29.10 21.24 56.00 46.00 -26.90 -24.76
1.400 0.09 25.14 19.33 25.23 19.42 56.00 46.00 -30.77 -26.58
2.017 0.07 28.80 22.77 28.87 22.84 56.00 46.00 -27.13 -23.16
3.498 0.06 37.79 32.18 37.85 32.24 56.00 46.00 -18.15 -13.76
5.287 0.20 42.78 37.26 42.98 37.46 60.00 50.00 -17.02 -12.54
5.923 0.22 41.23 35.61 41.45 35.83 60.00 50.00 -18.55 -14.17
9.966 0.46 38.39 33.34 38.85 33.80 60.00 50.00 -21.15 -16.20
13.529 0.62 40.62 35.29 41.24 35.91 60.00 50.00 -18.76 -14.09
22.185 0.99 24.45 19.34 25.44 20.33 60.00 50.00 -34.56 -29.67
29.509 1.21 21.39 16.37 22.60 17.58 60.00 50.00 -37.40 -32.42
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 32: LED LOAD (HLN-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 81 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8870
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 73.10 -- 73.88 -- 110.00 -- -36.12 --
0.050 0.65 85.10 -- 85.75 -- 90.00 -- -4.25 --
0.099 0.49 38.27 -- 38.76 -- 83.78 -- -45.02 --
0.150 0.58 47.29 38.31 47.87 38.89 66.00 56.00 -18.13 -17.11
0.162 0.58 42.48 33.31 43.06 33.89 65.36 55.36 -22.30 -21.47
0.244 0.57 37.78 34.55 38.35 35.12 61.96 51.96 -23.61 -16.84
0.533 0.57 37.17 33.58 37.74 34.15 56.00 46.00 -18.26 -11.85
1.002 0.58 31.72 24.43 32.30 25.01 56.00 46.00 -23.70 -20.99
1.408 0.57 28.90 21.89 29.47 22.46 56.00 46.00 -26.53 -23.54
1.998 0.55 29.47 22.11 30.02 22.66 56.00 46.00 -25.98 -23.34
3.537 0.55 38.47 32.23 39.02 32.78 56.00 46.00 -16.98 -13.22
4.779 0.65 42.21 36.47 42.86 37.12 56.00 46.00 -13.14 -8.88
5.994 0.70 41.34 35.43 42.04 36.13 60.00 50.00 -17.96 -13.87
9.896 0.92 39.05 33.72 39.97 34.64 60.00 50.00 -20.03 -15.36
22.068 1.38 21.90 17.09 23.28 18.47 60.00 50.00 -36.72 -31.53
29.560 1.59 20.72 16.10 22.31 17.69 60.00 56.00. -37.69 -32.31
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 32: LED LOAD (HLN-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 82 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8873
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 71.80 -- 71.87 -- 110.00 -- -38.13 --
0.050 0.04 84.60 -- 84.64 -- 90.00 -- -5.36 --
0.099 0.01 35.90 -- 35.91 -- 83.78 -- -47.87 --
0.162 0.11 42.28 34.36 42.39 34.47 65.36 55.36 -22.97 -20.89
0.240 0.11 40.81 37.09 40.92 37.20 62.10 52.10 -21.18 -14.90
0.548 0.11 27.01 18.59 27.12 18.70 56.00 46.00 -28.88 -27.30
0.998 0.11 30.03 23.88 30.14 23.99 56.00 46.00 -25.86 -22.01
1.404 0.09 24.92 17.52 25.01 17.61 56.00 46.00 -30.99 -28.39
3.494 0.06 39.82 33.55 39.88 33.61 56.00 46.00 -16.12 -12.39
5.365 0.20 42.68 35.71 42.88 35.91 60.00 50.00 -17.12 -14.09
5.974 0.22 40.65 35.03 40.87 35.25 60.00 50.00 -19.13 -14.75
10.142 0.47 32.25 26.74 32.72 27.21 60.00 50.00 -27.28 -22.79
12.627 0.58 39.03 33.41 39.61 33.99 60.00 50.00 -20.39 -16.01
22.103 0.98 29.39 24.51 30.37 25.49 60.00 50.00 -29.63 -24.51
29.599 1.22 21.88 16.51 23.10 17.73 60.00 50.00 -36.90 -32.27
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 33: LED LOAD (HLN-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 83 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8874
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 71.20 -- 71.98 -- 110.00 -- -38.02 --
0.050 0.65 84.70 -- 85.35 -- 90.00 -- -4.65 --
0.100 0.49 35.75 -- 36.24 -- 83.69 -- -47.45 --
0.162 0.58 42.77 34.70 43.35 35.28 65.36 55.36 -22.01 -20.08
0.189 0.57 46.45 42.86 47.02 43.43 64.08 54.08 -17.06 -10.65
0.244 0.57 39.59 33.77 40.16 34.34 61.96 51.96 -21.80 -17.62
0.548 0.57 29.19 18.94 29.76 19.51 56.00 46.00 -26.24 -26.49
0.998 0.58 33.88 27.02 34.46 27.60 56.00 46.00 -21.54 -18.40
1.388 0.57 30.43 22.57 31.00 23.14 56.00 46.00 -25.00 -22.86
1.990 0.55 32.56 24.87 33.11 25.42 56.00 46.00 -22.89 -20.58
3.486 0.54 39.41 32.83 39.95 33.37 56.00 46.00 -16.05 -12.63
4.935 0.66 41.45 35.68 42.11 36.34 56.00 46.00 -13.89 -9.66
5.966 0.70 41.06 35.34 41.76 36.04 60.00 50.00 -18.24 -13.96
9.978 0.93 33.19 27.96 34.12 28.89 60.00 50.00 -25.88 -21.11
22.127 1.38 28.21 23.73 29.59 25.11 60.00 50.00 -30.41 -24.89
29.900 1.60 20.44 15.40 22.04 17.00 60.00 50.00 -37.96 -33.00
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 33: LED LOAD (HLN-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 84 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8877
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 69.40 -- 69.47 -- 110.00 -- -40.53 --
0.050 0.04 84.30 -- 84.34 -- 90.00 -- -5.66 --
0.100 0.01 32.40 -- 32.41 -- 83.69 -- -51.28 --
0.150 0.11 43.89 35.90 44.00 36.01 66.00 56.00 -22.00 -19.99
0.162 0.11 40.75 32.49 40.86 32.60 65.36 55.36 -24.50 -22.76
0.240 0.11 32.82 23.55 32.93 23.66 62.10 52.10 -29.17 -28.44
0.545 0.11 33.23 26.94 33.34 27.05 56.00 46.00 -22.66 -18.95
0.998 0.11 28.53 19.02 28.64 19.13 56.00 46.00 -27.36 -26.87
1.377 0.09 24.49 19.06 24.58 19.15 56.00 46.00 -31.42 -26.85
2.017 0.07 33.93 25.23 34.00 25.30 56.00 46.00 -22.00 -20.70
3.525 0.07 41.02 35.03 41.09 35.10 56.00 46.00 -14.91 -10.90
5.681 0.21 44.52 39.04 44.73 39.25 60.00 50.00 -15.27 -10.75
6.068 0.22 43.94 38.46 44.16 38.68 60.00 50.00 -15.84 -11.32
10.103 0.46 38.61 33.54 39.07 34.00 60.00 50.00 -20.93 -16.00
22.005 0.97 29.96 25.23 30.93 26.20 60.00 50.00 -29.07 -23.80
29.470 1.21 23.39 17.81 24.60 19.02 60.00 50.00 -35.40 -30.98
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 34: LED LOAD (HLN-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 85 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8878
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 68.90 -- 69.68 -- 110.00 -- -40.32 --
0.050 0.65 83.90 -- 84.55 -- 90.00 -- -5.45 --
0.099 0.49 39.98 -- 40.47 -- 83.78 -- -43.31 --
0.162 0.58 40.43 33.31 41.01 33.89 65.36 55.36 -24.35 -21.47
0.177 0.57 43.55 38.55 44.12 39.12 64.63 54.63 -20.51 -15.51
0.244 0.57 32.38 23.91 32.95 24.48 61.96 51.96 -29.01 -27.48
0.545 0.57 33.51 29.25 34.08 29.82 56.00 46.00 -21.92 -16.18
1.002 0.58 32.28 26.05 32.86 26.63 56.00 46.00 -23.14 -19.37
1.404 0.57 30.22 22.23 30.79 22.80 56.00 46.00 -25.21 -23.20
1.998 0.55 34.08 26.94 34.63 27.49 56.00 46.00 -21.37 -18.51
3.537 0.55 39.97 34.37 40.52 34.92 56.00 46.00 -15.48 -11.08
5.724 0.69 44.46 38.98 45.15 39.67 60.00 50.00 -14.85 -10.33
6.017 0.70 44.52 39.26 45.22 39.96 60.00 50.00 -14.78 -10.04
9.927 0.93 39.12 33.95 40.05 34.88 60.00 50.00 -19.95 -15.12
21.752 1.36 28.37 23.69 29.73 25.05 60.00 50.00 -30.27 -24.95
29.685 1.59 21.47 16.56 23.06 18.15 60.00 50.00 -36.94 -31.85
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 34: LED LOAD (HLN-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 86 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8881
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 71.00 -- 71.07 -- 110.00 -- -38.93 --
0.050 0.04 80.20 -- 80.24 -- 90.00 -- -9.76 --
0.100 0.01 40.30 -- 40.31 -- 83.69 -- -43.38 --
0.162 0.11 50.24 37.10 50.35 37.21 65.36 55.36 -15.01 -18.15
0.244 0.11 32.60 22.55 32.71 22.66 61.96 51.96 -29.25 -29.30
0.548 0.11 36.64 32.08 36.75 32.19 56.00 46.00 -19.25 -13.81
0.998 0.11 31.64 24.60 31.75 24.71 56.00 46.00 -24.25 -21.29
1.400 0.09 22.14 17.40 22.23 17.49 56.00 46.00 -33.77 -28.51
1.990 0.07 35.04 27.81 35.11 27.88 56.00 46.00 -20.89 -18.12
3.505 0.07 42.52 36.19 42.59 36.26 56.00 46.00 -13.41 -9.74
4.580 0.15 44.59 38.94 44.74 39.09 56.00 46.00 -11.26 -6.91
5.935 0.22 47.54 41.71 47.76 41.93 60.00 50.00 -12.24 -8.07
10.041 0.46 40.52 35.00 40.98 35.46 60.00 50.00 -19.02 -14.54
22.138 0.98 30.65 25.77 31.63 26.75 60.00 50.00 -28.37 -23.25
29.802 1.22 21.73 15.27 22.95 16.49 60.00 50.00 -37.05 -33.51
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 35: LED LOAD (HLN-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 87 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8883
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 76.40 -- 77.18 -- 110.00 -- -32.82 --
0.050 0.65 81.10 -- 81.75 -- 90.00 -- -8.25 --
0.100 0.49 36.30 -- 36.79 -- 83.69 -- -46.90 --
0.162 0.58 51.03 37.70 51.61 38.28 65.36 55.36 -13.75 -17.08
0.166 0.58 50.94 39.02 51.52 39.60 65.16 55.16 -13.64 -15.56
0.244 0.57 30.91 20.62 31.48 21.19 61.96 51.96 -30.48 -30.77
0.552 0.57 37.80 32.21 38.37 32.78 56.00 46.00 -17.63 -13.22
0.998 0.58 35.14 26.43 35.72 27.01 56.00 46.00 -20.28 -18.99
1.392 0.57 28.09 19.96 28.66 20.53 56.00 46.00 -27.34 -25.47
1.986 0.55 36.26 28.92 36.81 29.47 56.00 46.00 -19.19 -16.53
3.494 0.54 43.36 36.90 43.90 37.44 56.00 46.00 -12.10 -8.56
4.431 0.61 46.31 40.29 46.92 40.90 56.00 46.00 -9.08 -5.10
5.986 0.70 46.90 41.64 47.60 42.34 60.00 50.00 -12.40 -7.66
10.002 0.93 40.66 35.12 41.59 36.05 60.00 50.00 -18.41 -13.95
21.986 1.37 29.77 25.00 31.14 26.37 60.00 50.00 -28.86 -23.63
29.900 1.60 18.06 13.02 19.66 14.62 60.00 50.00 -40.34 -35.38
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 35: LED LOAD (HLN-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 88 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8886
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Condution1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 72.80 -- 72.87 -- 110.00 -- -37.13 --
0.036 0.05 102.00 -- 102.05 -- 110.00 -- -7.95 --
0.050 0.04 83.00 -- 83.04 -- 90.00 -- -6.96 --
0.098 0.01 43.36 -- 43.37 -- 83.87 -- -40.50 --
0.162 0.11 41.38 31.77 41.49 31.88 65.36 55.36 -23.87 -23.48
0.240 0.11 36.84 34.21 36.95 34.32 62.10 52.10 -25.15 -17.78
0.545 0.11 29.01 19.34 29.12 19.45 56.00 46.00 -26.88 -26.55
0.998 0.11 24.83 18.77 24.94 18.88 56.00 46.00 -31.06 -27.12
1.392 0.09 22.49 17.08 22.58 17.17 56.00 46.00 -33.42 -28.83
2.017 0.07 32.32 24.27 32.39 24.34 56.00 46.00 -23.61 -21.66
3.486 0.06 38.78 33.24 38.84 33.30 56.00 46.00 -17.16 -12.70
5.943 0.22 44.42 38.63 44.64 38.85 60.00 50.00 -15.36 -11.15
9.990 0.46 38.90 33.73 39.36 34.19 60.00 50.00 -20.64 -15.81
21.978 0.97 31.42 26.51 32.39 27.48 60.00 50.00 -27.61 -22.52
29.810 1.22 23.79 18.59 25.01 19.81 60.00 50.00 -34.99 -30.19
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 36: LED LOAD (HLN-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 89 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8887
Temperature: 26.0 OPERATOR: Owen
Humidity: 50 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 65.08 -- 65.86 -- 110.00 -- -44.14 --
0.050 0.65 83.20 -- 83.85 -- 90.00 -- -6.15 --
0.099 0.49 40.80 -- 41.29 -- 83.78 -- -42.49 --
0.162 0.58 41.10 31.87 41.68 32.45 65.36 55.36 -23.68 -22.91
0.240 0.57 40.46 35.27 41.03 35.84 62.10 52.10 -21.07 -16.26
0.529 0.57 36.34 31.42 36.91 31.99 56.00 46.00 -19.09 -14.01
0.548 0.57 24.91 15.56 25.48 16.13 56.00 46.00 -30.52 -29.87
0.998 0.58 30.01 23.51 30.59 24.09 56.00 46.00 -25.41 -21.91
1.400 0.57 29.96 22.84 30.53 23.41 56.00 46.00 -25.47 -22.59
1.982 0.55 31.14 25.91 31.69 26.46 56.00 46.00 -24.31 -19.54
3.482 0.54 40.15 34.22 40.69 34.76 56.00 46.00 -15.31 -11.24
5.513 0.68 44.80 39.27 45.48 39.95 60.00 50.00 -14.52 -10.05
6.025 0.70 43.96 38.94 44.66 39.64 60.00 50.00 -15.34 -10.36
9.947 0.93 39.18 33.95 40.11 34.88 60.00 50.00 -19.89 -15.12
22.002 1.37 30.94 26.25 32.31 27.62 60.00 50.00 -27.69 -22.38
29.470 1.59 22.23 17.62 23.82 19.21 60.00 50.00 -36.18 -30.79
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 36: LED LOAD (HLN-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 90 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8890
Temperature: 24.0 OPERATOR: Owen
Humidity: 58 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.07 70.60 -- 70.67 -- 110.00 -- -39.33 --
0.050 0.04 84.60 -- 84.64 -- 90.00 -- -5.36 --
0.101 0.01 48.73 -- 48.74 -- 83.60 -- -34.86 --
0.150 0.11 51.04 38.47 51.15 38.58 66.00 56.00 -14.85 -17.42
0.162 0.11 40.48 32.98 40.59 33.09 65.36 55.36 -24.77 -22.27
0.548 0.11 35.45 30.29 35.56 30.40 56.00 46.00 -20.44 -15.60
1.002 0.11 31.78 24.95 31.89 25.06 56.00 46.00 -24.11 -20.94
1.404 0.09 23.29 15.45 23.38 15.54 56.00 46.00 -32.62 -30.46
2.021 0.07 31.83 25.19 31.90 25.26 56.00 46.00 -24.10 -20.74
3.517 0.07 40.46 35.14 40.53 35.21 56.00 46.00 -15.47 -10.79
4.963 0.18 44.09 39.24 44.27 39.42 56.00 46.00 -11.73 -6.58
5.966 0.22 44.76 40.00 44.98 40.22 60.00 50.00 -15.02 -9.78
9.912 0.46 39.64 34.68 40.10 35.14 60.00 50.00 -19.90 -14.86
22.048 0.98 28.52 23.81 29.50 24.79 60.00 50.00 -30.50 -25.21
29.818 1.22 16.55 12.15 17.77 13.37 60.00 50.00 -42.23 -36.63
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 37: LED LOAD (HLN-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 91 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/8891
Temperature: 24.0 OPERATOR: Owen
Humidity: 58 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.78 69.60 -- 70.38 -- 110.00 -- -39.62 --
0.050 0.65 84.80 -- 85.45 -- 90.00 -- -4.55 --
0.100 0.49 49.81 -- 50.30 -- 83.69 -- -33.39 --
0.150 0.58 51.20 38.00 51.78 38.58 66.00 56.00 -14.22 -17.42
0.162 0.58 41.59 33.61 42.17 34.19 65.36 55.36 -23.19 -21.17
0.240 0.57 33.97 24.37 34.54 24.94 62.10 52.10 -27.56 -27.16
0.548 0.57 36.63 31.54 37.20 32.11 56.00 46.00 -18.80 -13.89
0.998 0.58 35.11 28.46 35.69 29.04 56.00 46.00 -20.31 -16.96
1.408 0.57 28.52 21.77 29.09 22.34 56.00 46.00 -26.91 -23.66
2.009 0.55 32.80 26.42 33.35 26.97 56.00 46.00 -22.65 -19.03
3.533 0.55 40.18 34.95 40.73 35.50 56.00 46.00 -15.27 -10.50
5.170 0.67 44.20 39.15 44.87 39.82 60.00 50.00 -15.13 -10.18
6.064 0.70 44.65 39.58 45.35 40.28 60.00 50.00 -14.65 -9.72
9.998 0.93 38.90 33.90 39.83 34.83 60.00 50.00 -20.17 -15.17
21.752 1.36 31.24 26.34 32.60 27.70 60.00 50.00 -27.40 -22.30
29.412 1.59 23.27 17.29 24.86 18.88 60.00 50.00 -35.14 -31.12
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 37: LED LOAD (HLN-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 92 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Line
CLIENT: MEAN WELL DISTANCE:
MODEL: HLP-80H-48 Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/23
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.04 65.25 -- 65.29 -- 110.00 -- -44.71 --
0.050 0.04 81.40 -- 81.44 -- 90.00 -- -8.56 --
0.103 0.06 43.27 -- 43.33 -- 83.42 -- -40.09 --
0.154 0.14 49.10 40.30 49.24 40.44 65.78 55.78 -16.54 -15.34
0.204 0.14 46.00 39.80 46.14 39.94 63.45 53.45 -17.31 -13.51
0.560 0.14 27.49 22.67 27.63 22.81 56.00 46.00 -28.37 -23.19
1.009 0.15 24.56 19.69 24.71 19.84 56.00 46.00 -31.29 -26.16
1.404 0.14 23.51 18.45 23.65 18.59 56.00 46.00 -32.35 -27.41
2.002 0.12 24.62 18.04 24.74 18.16 56.00 46.00 -31.26 -27.84
3.752 0.13 24.09 16.92 24.22 17.05 56.00 46.00 -31.78 -28.95
6.173 0.26 24.06 19.65 24.32 19.91 60.00 50.00 -35.68 -30.09
9.291 0.41 29.38 24.62 29.79 25.03 60.00 50.00 -30.21 -24.97
14.337 0.67 42.57 35.13 43.24 35.80 60.00 50.00 -16.76 -14.20
23.552 1.01 33.49 28.06 34.50 29.07 60.00 50.00 -25.50 -20.93
28.861 1.13 25.08 19.81 26.21 20.94 60.00 50.00 -33.79 -29.06
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 38: LED LOAD (HLP-80H-48) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 93 of 385

Power Line Conducted Test Data


EUT: Switching Power Supply POLARITY: Neutral
CLIENT: MEAN WELL DISTANCE:
MODEL: HLP-80H-48 Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/22
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1
Frequency Factor Meter Reading (dBV) Emission Level (dBV) Limits (dBV) Margin (dB)
(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average
0.010 0.00 64.99 -- 64.99 -- 110.00 -- -45.01 --
0.050 0.02 81.20 -- 81.22 -- 90.00 -- -8.78 --
0.102 0.04 43.69 -- 43.73 -- 83.51 -- -39.78 --
0.152 0.13 49.20 41.10 49.33 41.23 65.89 55.89 -16.56 -14.66
0.205 0.13 46.76 41.51 46.89 41.64 63.41 53.41 -16.52 -11.77
0.236 0.13 33.77 24.54 33.90 24.67 62.24 52.24 -28.34 -27.57
0.482 0.13 19.09 12.43 19.22 12.56 56.30 46.30 -37.08 -33.74
1.029 0.14 22.51 17.59 22.65 17.73 56.00 46.00 -33.35 -28.27
1.384 0.13 24.05 19.29 24.18 19.42 56.00 46.00 -31.82 -26.58
2.017 0.11 25.43 19.46 25.54 19.57 56.00 46.00 -30.46 -26.43
3.834 0.13 27.32 22.40 27.45 22.53 56.00 46.00 -28.55 -23.47
5.943 0.25 29.08 24.46 29.33 24.71 60.00 50.00 -30.67 -25.29
10.017 0.48 31.46 26.70 31.94 27.18 60.00 50.00 -28.06 -22.82
14.439 0.71 42.74 34.90 43.45 35.61 60.00 50.00 -16.55 -14.39
24.009 1.07 30.56 25.04 31.63 26.11 60.00 50.00 -28.37 -23.89
28.927 1.14 22.13 17.27 23.27 18.41 60.00 50.00 -36.73 -31.59
Remark:
1. All readings are Quasi-Peak and Average values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015(QP)LC.LMT

Test Mode: Mode 38: LED LOAD (HLP-80H-48) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 94 of 385

3 Radiated Disturbance (9 kHz to 30 MHz) Measurement

3.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

EMI Test Receiver Rohde & Schwarz ESCS 30 830245/027 2011/10/05

RF Cable HARBOUR RG400 CBL32 2011/03/15

Triple Loop antenna Schaffner HLA6120 N/A 2011/07/12


Note: The above equipments are within the valid calibration period.

3.2 Block Diagram of Test Configuration

Triple Loop antenna

EMI Test 50 cm
Receiver
RF Cable

3.3 Radiated Electromagnetic Disturbance Limit


Limits for loop diameter
Frequency
dB (A)
(MHz)
2m
0.009 ~ 0.07 88
0.07 ~ 0.15 88 to 58
0.15 ~ 3.0 58 to 22
3.0 ~ 30 22

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 95 of 385

3.4 Instrument Configuration


3.4.1 Set the EMI test receiver frequency range from 9kHz to 30 MHz.
3.4.2 Set the EMI test receiver bandwidth at 200Hz, 9kHz.

3.5 Configuration of Measurement


3.5.1 The reference ground plane shall extend at least 0,5m beyond the boundaries of the
luminaire and have minimum dimensions of 2 x 2 m.
3.5.2 The EUT was placed on a non-conductive table center of the Triple Loop Antenna.

3.6 Test Result


PASS.
The final test data is shown as following pages.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 96 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9862
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 47.02 -- 47.12 -- 88.00 -- -40.88 --


0.048 0.10 37.24 -- 37.34 -- 88.00 -- -50.66 --
0.097 0.10 35.21 -- 35.31 -- 75.16 -- -39.85 --
0.150 0.10 37.04 -- 37.14 -- 58.00 -- -20.86 --
0.193 0.10 32.92 -- 33.02 -- 54.97 -- -21.95 --
0.295 0.10 25.54 -- 25.64 -- 49.87 -- -24.23 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 1: LED LOAD (HLG-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 97 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9863
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 44.15 -- 44.25 -- 88.00 -- -43.75 --


0.048 0.10 35.39 -- 35.49 -- 88.00 -- -52.51 --
0.097 0.10 35.43 -- 35.53 -- 75.16 -- -39.63 --
0.145 0.10 31.13 -- 31.23 -- 59.33 -- -28.10 --
0.193 0.10 29.59 -- 29.69 -- 54.97 -- -25.28 --
0.244 0.10 24.86 -- 24.96 -- 52.15 -- -27.19 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 1: LED LOAD (HLG-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 98 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9864
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 41.58 -- 41.68 -- 88.00 -- -46.32 --


0.097 0.10 40.62 -- 40.72 -- 75.16 -- -34.44 --
0.145 0.10 37.14 -- 37.24 -- 59.33 -- -22.09 --
0.193 0.10 35.99 -- 36.09 -- 54.97 -- -18.88 --
0.240 0.10 31.24 -- 31.34 -- 52.35 -- -21.01 --
0.291 0.10 28.65 -- 28.75 -- 50.04 -- -21.29 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 1: LED LOAD (HLG-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 99 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9873
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 47.77 -- 47.87 -- 88.00 -- -40.13 --


0.048 0.10 37.28 -- 37.38 -- 88.00 -- -50.62 --
0.097 0.10 36.90 -- 37.00 -- 75.16 -- -38.16 --
0.145 0.10 32.16 -- 32.26 -- 59.33 -- -27.07 --
0.189 0.10 29.28 -- 29.38 -- 55.22 -- -25.84 --
0.244 0.10 28.19 -- 28.29 -- 52.15 -- -23.86 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 2: LED LOAD (HLG-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 100 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9872
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 44.28 -- 44.38 -- 88.00 -- -43.62 --


0.048 0.10 36.21 -- 36.31 -- 88.00 -- -51.69 --
0.097 0.10 35.45 -- 35.55 -- 75.16 -- -39.61 --
0.145 0.10 31.20 -- 31.30 -- 59.33 -- -28.03 --
0.193 0.10 29.44 -- 29.54 -- 54.97 -- -25.43 --
0.240 0.10 25.11 -- 25.21 -- 52.35 -- -27.14 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 2: LED LOAD (HLG-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 101 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9871
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 41.64 -- 41.74 -- 88.00 -- -46.26 --


0.097 0.10 40.70 -- 40.80 -- 75.16 -- -34.36 --
0.145 0.10 37.22 -- 37.32 -- 59.33 -- -22.01 --
0.193 0.10 35.80 -- 35.90 -- 54.97 -- -19.07 --
0.240 0.10 31.43 -- 31.53 -- 52.35 -- -20.82 --
0.291 0.10 28.53 -- 28.63 -- 50.04 -- -21.41 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 2: LED LOAD (HLG-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 102 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9874
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 46.84 -- 46.94 -- 88.00 -- -41.06 --


0.048 0.10 37.32 -- 37.42 -- 88.00 -- -50.58 --
0.097 0.10 37.02 -- 37.12 -- 75.16 -- -38.04 --
0.140 0.10 34.00 -- 34.10 -- 60.72 -- -26.62 --
0.193 0.10 32.61 -- 32.71 -- 54.97 -- -22.26 --
0.287 0.10 25.33 -- 25.43 -- 50.20 -- -24.77 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 3: LED LOAD (HLG-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 103 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9875
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 44.36 -- 44.46 -- 88.00 -- -43.54 --


0.048 0.10 35.53 -- 35.63 -- 88.00 -- -52.37 --
0.097 0.10 35.51 -- 35.61 -- 75.16 -- -39.55 --
0.150 0.10 30.70 -- 30.80 -- 58.00 -- -27.20 --
0.193 0.10 29.93 -- 30.03 -- 54.97 -- -24.94 --
0.291 0.10 23.26 -- 23.36 -- 50.04 -- -26.68 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 3: LED LOAD (HLG-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 104 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9876
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 41.66 -- 41.76 -- 88.00 -- -46.24 --


0.097 0.10 40.72 -- 40.82 -- 75.16 -- -34.34 --
0.145 0.10 37.30 -- 37.40 -- 59.33 -- -21.93 --
0.193 0.10 35.76 -- 35.86 -- 54.97 -- -19.11 --
0.244 0.10 31.12 -- 31.22 -- 52.15 -- -20.93 --
0.291 0.10 28.53 -- 28.63 -- 50.04 -- -21.41 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 3: LED LOAD (HLG-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 105 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9885
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 47.71 -- 47.81 -- 88.00 -- -40.19 --


0.048 0.10 37.28 -- 37.38 -- 88.00 -- -50.62 --
0.097 0.10 36.90 -- 37.00 -- 75.16 -- -38.16 --
0.145 0.10 32.20 -- 32.30 -- 59.33 -- -27.03 --
0.193 0.10 31.24 -- 31.34 -- 54.97 -- -23.63 --
0.291 0.10 25.15 -- 25.25 -- 50.04 -- -24.79 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 4: LED LOAD (HLG-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 106 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9884
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 44.09 -- 44.19 -- 88.00 -- -43.81 --


0.048 0.10 35.53 -- 35.63 -- 88.00 -- -52.37 --
0.097 0.10 35.53 -- 35.63 -- 75.16 -- -39.53 --
0.145 0.10 31.24 -- 31.34 -- 59.33 -- -27.99 --
0.193 0.10 30.07 -- 30.17 -- 54.97 -- -24.80 --
0.287 0.10 22.83 -- 22.93 -- 50.20 -- -27.27 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 4: LED LOAD (HLG-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 107 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9883
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 41.68 -- 41.78 -- 88.00 -- -46.22 --


0.097 0.10 40.72 -- 40.82 -- 75.16 -- -34.34 --
0.145 0.10 37.20 -- 37.30 -- 59.33 -- -22.03 --
0.193 0.10 35.70 -- 35.80 -- 54.97 -- -19.17 --
0.240 0.10 31.34 -- 31.44 -- 52.35 -- -20.91 --
0.291 0.10 28.55 -- 28.65 -- 50.04 -- -21.39 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 4: LED LOAD (HLG-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 108 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9886
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 44.26 -- 44.36 -- 88.00 -- -43.64 --


0.048 0.10 39.23 -- 39.33 -- 88.00 -- -48.67 --
0.097 0.10 35.51 -- 35.61 -- 75.16 -- -39.55 --
0.145 0.10 28.97 -- 29.07 -- 59.33 -- -30.26 --
0.201 0.10 31.74 -- 31.84 -- 54.48 -- -22.64 --
11.271 0.10 8.74 -- 8.84 -- 22.00 -- -13.16 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 5: LED LOAD (HLG-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 109 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9887
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 43.17 -- 43.27 -- 88.00 -- -44.73 --


0.048 0.10 38.30 -- 38.40 -- 88.00 -- -49.60 --
0.097 0.10 35.49 -- 35.59 -- 75.16 -- -39.57 --
0.145 0.10 30.50 -- 30.60 -- 59.33 -- -28.73 --
0.193 0.10 29.36 -- 29.46 -- 54.97 -- -25.51 --
7.865 0.10 8.11 -- 8.21 -- 22.00 -- -13.79 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 5: LED LOAD (HLG-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 110 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9888
Temperature: 28.1 OPERATOR: Elli
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 43.24 -- 43.34 -- 88.00 -- -44.66 --


0.048 0.10 44.28 -- 44.38 -- 88.00 -- -43.62 --
0.097 0.10 40.70 -- 40.80 -- 75.16 -- -34.36 --
0.193 0.10 35.48 -- 35.58 -- 54.97 -- -19.39 --
0.240 0.10 30.41 -- 30.51 -- 52.35 -- -21.84 --
9.814 0.10 8.12 -- 8.22 -- 22.00 -- -13.78 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 5: LED LOAD (HLG-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 111 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9897
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 48.30 -- 48.40 -- 88.00 -- -39.60 --


0.048 0.10 37.74 -- 37.84 -- 88.00 -- -50.16 --
0.097 0.10 36.96 -- 37.06 -- 75.16 -- -38.10 --
0.150 0.10 35.74 -- 35.84 -- 58.00 -- -22.16 --
0.193 0.10 32.01 -- 32.11 -- 54.97 -- -22.86 --
0.255 0.10 23.27 -- 23.37 -- 51.62 -- -28.25 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 6: LED LOAD (HLG-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 112 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9896
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 46.05 -- 46.15 -- 88.00 -- -41.85 --


0.048 0.10 35.99 -- 36.09 -- 88.00 -- -51.91 --
0.097 0.10 35.49 -- 35.59 -- 75.16 -- -39.57 --
0.145 0.10 31.30 -- 31.40 -- 59.33 -- -27.93 --
0.193 0.10 30.54 -- 30.64 -- 54.97 -- -24.33 --
0.240 0.10 25.15 -- 25.25 -- 52.35 -- -27.10 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 6: LED LOAD (HLG-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 113 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9895
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 42.13 -- 42.23 -- 88.00 -- -45.77 --


0.097 0.10 40.54 -- 40.64 -- 75.16 -- -34.52 --
0.193 0.10 35.46 -- 35.56 -- 54.97 -- -19.41 --
0.244 0.10 30.48 -- 30.58 -- 52.15 -- -21.57 --
0.291 0.10 28.25 -- 28.35 -- 50.04 -- -21.69 --
0.338 0.10 25.26 -- 25.36 -- 48.24 -- -22.88 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 6: LED LOAD (HLG-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 114 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9898
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 48.22 -- 48.32 -- 88.00 -- -39.68 --


0.048 0.10 37.64 -- 37.74 -- 88.00 -- -50.26 --
0.097 0.10 36.94 -- 37.04 -- 75.16 -- -38.12 --
0.140 0.10 34.14 -- 34.24 -- 60.72 -- -26.48 --
0.193 0.10 31.69 -- 31.79 -- 54.97 -- -23.18 --
0.244 0.10 27.37 -- 27.47 -- 52.15 -- -24.68 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 7: LED LOAD (HLG-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 115 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9899
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 46.06 -- 46.16 -- 88.00 -- -41.84 --


0.048 0.10 35.89 -- 35.99 -- 88.00 -- -52.01 --
0.097 0.10 35.55 -- 35.65 -- 75.16 -- -39.51 --
0.150 0.10 31.20 -- 31.30 -- 58.00 -- -26.70 --
0.193 0.10 30.36 -- 30.46 -- 54.97 -- -24.51 --
0.240 0.10 25.25 -- 25.35 -- 52.35 -- -27.00 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 7: LED LOAD (HLG-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 116 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9900
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 42.03 -- 42.13 -- 88.00 -- -45.87 --


0.097 0.10 40.74 -- 40.84 -- 75.16 -- -34.32 --
0.145 0.10 37.32 -- 37.42 -- 59.33 -- -21.91 --
0.193 0.10 35.62 -- 35.72 -- 54.97 -- -19.25 --
0.240 0.10 31.22 -- 31.32 -- 52.35 -- -21.03 --
0.291 0.10 28.25 -- 28.35 -- 50.04 -- -21.69 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 7: LED LOAD (HLG-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 117 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/97
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.56 -- 37.56 -- 75.16 -- -37.60 --


0.154 0.10 40.02 -- 40.12 -- 57.68 -- -17.56 --
0.166 0.10 36.30 -- 36.40 -- 56.78 -- -20.38 --
0.193 0.10 34.90 -- 35.00 -- 54.97 -- -19.97 --
0.228 0.10 29.93 -- 30.03 -- 52.97 -- -22.94 --
0.295 0.10 24.87 -- 24.97 -- 49.87 -- -24.90 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 8: LED LOAD (HLG-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 118 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/98
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 36.10 -- 36.10 -- 75.16 -- -39.06 --


0.145 0.00 32.16 -- 32.16 -- 59.33 -- -27.17 --
0.193 0.03 31.68 -- 31.71 -- 54.97 -- -23.26 --
0.240 0.06 26.79 -- 26.85 -- 52.35 -- -25.50 --
0.291 0.09 24.23 -- 24.32 -- 50.04 -- -25.72 --
0.338 0.08 21.07 -- 21.15 -- 48.24 -- -27.09 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 8: LED LOAD (HLG-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 119 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/99
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.145 0.00 37.84 -- 37.84 -- 59.33 -- -21.49 --


0.193 0.03 36.33 -- 36.36 -- 54.97 -- -18.61 --
0.244 0.06 31.46 -- 31.52 -- 52.15 -- -20.63 --
0.291 0.09 29.33 -- 29.42 -- 50.04 -- -20.62 --
0.338 0.08 26.47 -- 26.55 -- 48.24 -- -21.69 --
0.388 0.06 23.06 -- 23.12 -- 46.58 -- -23.46 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 8: LED LOAD (HLG-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 120 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9909
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 47.41 -- 47.51 -- 88.00 -- -40.49 --


0.048 0.10 37.14 -- 37.24 -- 88.00 -- -50.76 --
0.097 0.10 36.84 -- 36.94 -- 75.16 -- -38.22 --
0.150 0.10 35.16 -- 35.26 -- 58.00 -- -22.74 --
0.205 0.10 28.71 -- 28.81 -- 54.25 -- -25.44 --
0.244 0.10 26.80 -- 26.90 -- 52.15 -- -25.25 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 9: LED LOAD (HLG-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 121 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9908
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 44.78 -- 44.88 -- 88.00 -- -43.12 --


0.048 0.10 35.07 -- 35.17 -- 88.00 -- -52.83 --
0.097 0.10 35.03 -- 35.13 -- 75.16 -- -40.03 --
0.145 0.10 30.85 -- 30.95 -- 59.33 -- -28.38 --
0.193 0.10 29.00 -- 29.10 -- 54.97 -- -25.87 --
0.240 0.10 24.58 -- 24.68 -- 52.35 -- -27.67 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 9: LED LOAD (HLG-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 122 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/9907
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 41.16 -- 41.26 -- 88.00 -- -46.74 --


0.097 0.10 40.10 -- 40.20 -- 75.16 -- -34.96 --
0.145 0.10 36.84 -- 36.94 -- 59.33 -- -22.39 --
0.193 0.10 35.00 -- 35.10 -- 54.97 -- -19.87 --
0.240 0.10 30.42 -- 30.52 -- 52.35 -- -21.83 --
0.291 0.10 27.70 -- 27.80 -- 50.04 -- -22.24 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 9: LED LOAD (HLG-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 123 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8964
Temperature: 28.0 OPERATOR: OWEN
Humidity: 50 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 39.33 -- 39.43 -- 88.00 -- -48.57 --


0.097 0.10 37.02 -- 37.12 -- 75.16 -- -38.04 --
0.145 0.10 31.88 -- 31.98 -- 59.33 -- -27.35 --
0.181 0.10 31.74 -- 31.84 -- 55.74 -- -23.90 --
0.248 0.10 25.44 -- 25.54 -- 51.96 -- -26.42 --
0.291 0.10 27.12 -- 27.22 -- 50.04 -- -22.82 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 10: LED LOAD (HLN-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 124 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8968
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 35.70 -- 35.70 -- 75.16 -- -39.46 --


0.145 0.00 31.65 -- 31.65 -- 59.33 -- -27.68 --
0.166 0.01 31.40 -- 31.41 -- 56.78 -- -25.37 --
0.193 0.03 31.13 -- 31.16 -- 54.97 -- -23.81 --
0.244 0.06 26.35 -- 26.41 -- 52.15 -- -25.74 --
0.291 0.09 23.68 -- 23.77 -- 50.04 -- -26.27 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 10: LED LOAD (HLN-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 125 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8969
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 40.59 -- 40.59 -- 75.16 -- -34.57 --


0.145 0.00 37.33 -- 37.33 -- 59.33 -- -22.00 --
0.193 0.03 35.89 -- 35.92 -- 54.97 -- -19.05 --
0.244 0.06 31.28 -- 31.34 -- 52.15 -- -20.81 --
0.287 0.09 25.52 -- 25.61 -- 50.20 -- -24.59 --
0.338 0.08 25.33 -- 25.41 -- 48.24 -- -22.83 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 10: LED LOAD (HLN-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 126 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8970
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 36.86 -- 36.86 -- 75.16 -- -38.30 --


0.145 0.00 32.75 -- 32.75 -- 59.33 -- -26.58 --
0.158 0.01 35.04 -- 35.05 -- 57.38 -- -22.33 --
0.170 0.01 32.69 -- 32.70 -- 56.50 -- -23.80 --
0.193 0.03 31.99 -- 32.02 -- 54.97 -- -22.95 --
0.228 0.05 28.31 -- 28.36 -- 52.97 -- -24.61 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 11: LED LOAD (HLN-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 127 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8971
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 35.44 -- 35.44 -- 75.16 -- -39.72 --


0.145 0.00 31.65 -- 31.65 -- 59.33 -- -27.68 --
0.166 0.01 32.02 -- 32.03 -- 56.78 -- -24.75 --
0.193 0.03 31.49 -- 31.52 -- 54.97 -- -23.45 --
0.240 0.06 26.17 -- 26.23 -- 52.35 -- -26.12 --
0.291 0.09 23.66 -- 23.75 -- 50.04 -- -26.29 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 11: LED LOAD (HLN-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 128 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8972
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 40.36 -- 40.36 -- 75.16 -- -34.80 --


0.145 0.00 37.28 -- 37.28 -- 59.33 -- -22.05 --
0.193 0.03 35.78 -- 35.81 -- 54.97 -- -19.16 --
0.244 0.06 31.33 -- 31.39 -- 52.15 -- -20.76 --
0.291 0.09 28.44 -- 28.53 -- 50.04 -- -21.51 --
0.338 0.08 24.95 -- 25.03 -- 48.24 -- -23.21 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 11: LED LOAD (HLN-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 129 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8973
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.46 -- 37.46 -- 75.16 -- -37.70 --


0.141 0.00 33.83 -- 33.83 -- 60.44 -- -26.61 --
0.166 0.01 37.84 -- 37.85 -- 56.78 -- -18.93 --
0.193 0.03 36.35 -- 36.38 -- 54.97 -- -18.59 --
0.255 0.07 30.87 -- 30.94 -- 51.62 -- -20.68 --
0.291 0.09 26.18 -- 26.27 -- 50.04 -- -23.77 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 12: LED LOAD (HLN-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 130 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8974
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 35.97 -- 35.97 -- 75.16 -- -39.19 --


0.145 0.00 32.16 -- 32.16 -- 59.33 -- -27.17 --
0.166 0.01 33.06 -- 33.07 -- 56.78 -- -23.71 --
0.193 0.03 32.20 -- 32.23 -- 54.97 -- -22.74 --
0.240 0.06 26.99 -- 27.05 -- 52.35 -- -25.30 --
0.291 0.09 24.56 -- 24.65 -- 50.04 -- -25.39 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 12: LED LOAD (HLN-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 131 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8975
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.150 0.00 32.17 -- 32.17 -- 58.00 -- -25.83 --


0.193 0.03 36.53 -- 36.56 -- 54.97 -- -18.41 --
0.244 0.06 31.95 -- 32.01 -- 52.15 -- -20.14 --
0.291 0.09 29.41 -- 29.50 -- 50.04 -- -20.54 --
0.338 0.08 26.43 -- 26.51 -- 48.24 -- -21.73 --
0.388 0.06 23.26 -- 23.32 -- 46.58 -- -23.26 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 12: LED LOAD (HLN-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 132 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8976
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.13 -- 37.13 -- 75.16 -- -38.03 --


0.141 0.00 36.18 -- 36.18 -- 60.44 -- -24.26 --
0.166 0.01 39.08 -- 39.09 -- 56.78 -- -17.69 --
0.193 0.03 35.93 -- 35.96 -- 54.97 -- -19.01 --
0.244 0.06 33.30 -- 33.36 -- 52.15 -- -18.79 --
0.295 0.10 25.59 -- 25.69 -- 49.87 -- -24.18 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 13: LED LOAD (HLN-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 133 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8977
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 36.10 -- 36.10 -- 75.16 -- -39.06 --


0.141 0.00 27.36 -- 27.36 -- 60.44 -- -33.08 --
0.177 0.02 28.24 -- 28.26 -- 56.01 -- -27.75 --
0.193 0.03 31.53 -- 31.56 -- 54.97 -- -23.41 --
0.244 0.06 27.01 -- 27.07 -- 52.15 -- -25.08 --
0.291 0.09 24.19 -- 24.28 -- 50.04 -- -25.76 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 13: LED LOAD (HLN-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 134 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8978
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.145 0.00 37.29 -- 37.29 -- 59.33 -- -22.04 --


0.193 0.03 36.29 -- 36.32 -- 54.97 -- -18.65 --
0.240 0.06 31.99 -- 32.05 -- 52.35 -- -20.30 --
0.291 0.09 29.19 -- 29.28 -- 50.04 -- -20.76 --
0.338 0.08 26.05 -- 26.13 -- 48.24 -- -22.11 --
0.388 0.06 23.18 -- 23.24 -- 46.58 -- -23.34 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 13: LED LOAD (HLN-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 135 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8979
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.29 -- 37.29 -- 75.16 -- -37.87 --


0.128 0.00 34.12 -- 34.12 -- 64.24 -- -30.12 --
0.140 0.00 36.26 -- 36.26 -- 60.72 -- -24.46 --
0.177 0.02 34.48 -- 34.50 -- 56.01 -- -21.51 --
0.193 0.03 34.63 -- 34.66 -- 54.97 -- -20.31 --
0.255 0.07 33.44 -- 33.51 -- 51.62 -- -18.11 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 14: LED LOAD (HLN-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 136 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8980
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 36.12 -- 36.12 -- 75.16 -- -39.04 --


0.145 0.00 31.83 -- 31.83 -- 59.33 -- -27.50 --
0.166 0.01 33.26 -- 33.27 -- 56.78 -- -23.51 --
0.177 0.02 28.78 -- 28.80 -- 56.01 -- -27.21 --
0.197 0.03 27.31 -- 27.34 -- 54.72 -- -27.38 --
0.244 0.06 27.26 -- 27.32 -- 52.15 -- -24.83 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 14: LED LOAD (HLN-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 137 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8981
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 41.09 -- 41.09 -- 75.16 -- -34.07 --


0.145 0.00 37.50 -- 37.50 -- 59.33 -- -21.83 --
0.193 0.03 36.29 -- 36.32 -- 54.97 -- -18.65 --
0.244 0.06 32.05 -- 32.11 -- 52.15 -- -20.04 --
0.291 0.09 29.25 -- 29.34 -- 50.04 -- -20.70 --
0.338 0.08 25.77 -- 25.85 -- 48.24 -- -22.39 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 14: LED LOAD (HLN-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 138 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8982
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.32 -- 37.32 -- 75.16 -- -37.84 --


0.128 0.00 35.17 -- 35.17 -- 64.24 -- -29.07 --
0.141 0.00 35.15 -- 35.15 -- 60.44 -- -25.29 --
0.166 0.01 37.76 -- 37.77 -- 56.78 -- -19.01 --
0.205 0.04 35.57 -- 35.61 -- 54.25 -- -18.64 --
0.232 0.05 30.82 -- 30.87 -- 52.76 -- -21.89 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 15: LED LOAD (HLN-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 139 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8983
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 36.02 -- 36.02 -- 75.16 -- -39.14 --


0.154 0.00 36.14 -- 36.14 -- 57.68 -- -21.54 --
0.166 0.01 33.63 -- 33.64 -- 56.78 -- -23.14 --
0.201 0.03 24.24 -- 24.27 -- 54.48 -- -30.21 --
0.244 0.06 26.95 -- 27.01 -- 52.15 -- -25.14 --
0.291 0.09 23.61 -- 23.70 -- 50.04 -- -26.34 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 15: LED LOAD (HLN-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 140 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8984
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 40.82 -- 40.82 -- 75.16 -- -34.34 --


0.145 0.00 37.35 -- 37.35 -- 59.33 -- -21.98 --
0.193 0.03 36.04 -- 36.07 -- 54.97 -- -18.90 --
0.240 0.06 31.79 -- 31.85 -- 52.35 -- -20.50 --
0.291 0.09 28.80 -- 28.89 -- 50.04 -- -21.15 --
0.338 0.08 25.44 -- 25.52 -- 48.24 -- -22.72 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 15: LED LOAD (HLN-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 141 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8985
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 35.23 -- 35.23 -- 75.16 -- -39.93 --


0.128 0.00 29.84 -- 29.84 -- 64.24 -- -34.40 --
0.141 0.00 33.67 -- 33.67 -- 60.44 -- -26.77 --
0.170 0.01 34.40 -- 34.41 -- 56.50 -- -22.09 --
0.255 0.07 32.90 -- 32.97 -- 51.62 -- -18.65 --
0.306 0.10 25.00 -- 25.10 -- 49.43 -- -24.33 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 16: LED LOAD (HLN-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 142 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8986
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 36.04 -- 36.04 -- 75.16 -- -39.12 --


0.150 0.00 34.41 -- 34.41 -- 58.00 -- -23.59 --
0.193 0.03 32.08 -- 32.11 -- 54.97 -- -22.86 --
0.240 0.06 26.66 -- 26.72 -- 52.35 -- -25.63 --
0.291 0.09 23.61 -- 23.70 -- 50.04 -- -26.34 --
0.338 0.08 20.29 -- 20.37 -- 48.24 -- -27.87 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 16: LED LOAD (HLN-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 143 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8987
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 40.82 -- 40.82 -- 75.16 -- -34.34 --


0.150 0.00 31.62 -- 31.62 -- 58.00 -- -26.38 --
0.193 0.03 36.08 -- 36.11 -- 54.97 -- -18.86 --
0.240 0.06 31.89 -- 31.95 -- 52.35 -- -20.40 --
0.291 0.09 28.73 -- 28.82 -- 50.04 -- -21.22 --
0.338 0.08 25.53 -- 25.61 -- 48.24 -- -22.63 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 16: LED LOAD (HLN-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 144 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8988
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.06 -- 37.06 -- 75.16 -- -38.10 --


0.128 0.00 29.25 -- 29.25 -- 64.24 -- -34.99 --
0.141 0.00 30.57 -- 30.57 -- 60.44 -- -29.87 --
0.166 0.01 37.08 -- 37.09 -- 56.78 -- -19.69 --
0.177 0.02 33.83 -- 33.85 -- 56.01 -- -22.16 --
0.193 0.03 30.47 -- 30.50 -- 54.97 -- -24.47 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 17: LED LOAD (HLN-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 145 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8989
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 35.53 -- 35.53 -- 75.16 -- -39.63 --


0.154 0.00 34.90 -- 34.90 -- 57.68 -- -22.78 --
0.170 0.01 28.74 -- 28.75 -- 56.50 -- -27.75 --
0.193 0.03 31.46 -- 31.49 -- 54.97 -- -23.48 --
0.244 0.06 26.76 -- 26.82 -- 52.15 -- -25.33 --
0.291 0.09 23.31 -- 23.40 -- 50.04 -- -26.64 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 17: LED LOAD (HLN-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 146 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8990
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 40.38 -- 40.38 -- 75.16 -- -34.78 --


0.145 0.00 37.20 -- 37.20 -- 59.33 -- -22.13 --
0.193 0.03 35.74 -- 35.77 -- 54.97 -- -19.20 --
0.240 0.06 31.31 -- 31.37 -- 52.35 -- -20.98 --
0.291 0.09 28.54 -- 28.63 -- 50.04 -- -21.41 --
0.338 0.08 25.15 -- 25.23 -- 48.24 -- -23.01 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 17: LED LOAD (HLN-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 147 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8991
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 36.88 -- 36.88 -- 75.16 -- -38.28 --


0.140 0.00 34.47 -- 34.47 -- 60.72 -- -26.25 --
0.170 0.01 34.00 -- 34.01 -- 56.50 -- -22.49 --
0.193 0.03 34.71 -- 34.74 -- 54.97 -- -20.23 --
0.244 0.06 32.05 -- 32.11 -- 52.15 -- -20.04 --
0.295 0.10 24.32 -- 24.42 -- 49.87 -- -25.45 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 18: LED LOAD (HLN-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 148 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8992
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 35.51 -- 35.51 -- 75.16 -- -39.65 --


0.150 0.00 33.69 -- 33.69 -- 58.00 -- -24.31 --
0.193 0.03 31.43 -- 31.46 -- 54.97 -- -23.51 --
0.240 0.06 26.23 -- 26.29 -- 52.35 -- -26.06 --
0.291 0.09 23.33 -- 23.42 -- 50.04 -- -26.62 --
0.338 0.08 19.68 -- 19.76 -- 48.24 -- -28.48 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 18: LED LOAD (HLN-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 149 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/8993
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 40.38 -- 40.38 -- 75.16 -- -34.78 --


0.145 0.00 37.20 -- 37.20 -- 59.33 -- -22.13 --
0.193 0.03 35.74 -- 35.77 -- 54.97 -- -19.20 --
0.240 0.06 31.31 -- 31.37 -- 52.35 -- -20.98 --
0.291 0.09 28.54 -- 28.63 -- 50.04 -- -21.41 --
0.338 0.08 25.15 -- 25.23 -- 48.24 -- -23.01 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 18: LED LOAD (HLN-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 150 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLP-80H-48 Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/106
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.42 -- 37.42 -- 75.16 -- -37.74 --


0.154 0.00 40.21 -- 40.21 -- 57.68 -- -17.47 --
0.201 0.03 33.51 -- 33.54 -- 54.48 -- -20.94 --
0.244 0.06 31.71 -- 31.77 -- 52.15 -- -20.38 --
0.291 0.09 25.90 -- 25.99 -- 50.04 -- -24.05 --
0.341 0.08 19.57 -- 19.65 -- 48.13 -- -28.48 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 19: LED LOAD (HLP-80H-48) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 151 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLP-80H-48 Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/107
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 35.64 -- 35.64 -- 75.16 -- -39.52 --


0.150 0.00 32.68 -- 32.68 -- 58.00 -- -25.32 --
0.166 0.01 30.56 -- 30.57 -- 56.78 -- -26.21 --
0.193 0.03 31.25 -- 31.28 -- 54.97 -- -23.69 --
0.240 0.06 26.30 -- 26.36 -- 52.35 -- -25.99 --
0.291 0.09 23.93 -- 24.02 -- 50.04 -- -26.02 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 19: LED LOAD (HLP-80H-48) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 152 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLP-80H-48 Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/108
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.145 0.00 37.68 -- 37.68 -- 59.33 -- -21.65 --


0.193 0.03 36.27 -- 36.30 -- 54.97 -- -18.67 --
0.240 0.06 31.69 -- 31.75 -- 52.35 -- -20.60 --
0.291 0.09 29.19 -- 29.28 -- 50.04 -- -20.76 --
0.338 0.08 26.11 -- 26.19 -- 48.24 -- -22.05 --
0.388 0.06 23.04 -- 23.10 -- 46.58 -- -23.48 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 19: LED LOAD (HLP-80H-48) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 153 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9867
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 46.92 -- 47.02 -- 88.00 -- -40.98 --


0.048 0.10 37.28 -- 37.38 -- 88.00 -- -50.62 --
0.097 0.10 33.43 -- 33.53 -- 75.16 -- -41.63 --
0.150 0.10 33.31 -- 33.41 -- 58.00 -- -24.59 --
0.193 0.10 32.31 -- 32.41 -- 54.97 -- -22.56 --
0.244 0.10 26.07 -- 26.17 -- 52.15 -- -25.98 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 20: LED LOAD (HLG-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 154 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9866
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 43.99 -- 44.09 -- 88.00 -- -43.91 --


0.048 0.10 35.45 -- 35.55 -- 88.00 -- -52.45 --
0.097 0.10 33.05 -- 33.15 -- 75.16 -- -42.01 --
0.145 0.10 31.17 -- 31.27 -- 59.33 -- -28.06 --
0.193 0.10 29.79 -- 29.89 -- 54.97 -- -25.08 --
0.291 0.10 23.56 -- 23.66 -- 50.04 -- -26.38 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 20: LED LOAD (HLG-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 155 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9865
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 41.58 -- 41.68 -- 88.00 -- -46.32 --


0.097 0.10 41.34 -- 41.44 -- 75.16 -- -33.72 --
0.193 0.10 36.05 -- 36.15 -- 54.97 -- -18.82 --
0.244 0.10 30.50 -- 30.60 -- 52.15 -- -21.55 --
0.291 0.10 28.71 -- 28.81 -- 50.04 -- -21.23 --
0.338 0.10 25.24 -- 25.34 -- 48.24 -- -22.90 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 20: LED LOAD (HLG-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 156 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9868
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 47.16 -- 47.26 -- 88.00 -- -40.74 --


0.048 0.10 37.30 -- 37.40 -- 88.00 -- -50.60 --
0.097 0.10 36.98 -- 37.08 -- 75.16 -- -38.08 --
0.150 0.10 36.17 -- 36.27 -- 58.00 -- -21.73 --
0.193 0.10 32.09 -- 32.19 -- 54.97 -- -22.78 --
0.295 0.10 25.74 -- 25.84 -- 49.87 -- -24.03 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 21: LED LOAD (HLG-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 157 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9869
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 43.56 -- 43.66 -- 88.00 -- -44.34 --


0.048 0.10 35.49 -- 35.59 -- 88.00 -- -52.41 --
0.097 0.10 35.53 -- 35.63 -- 75.16 -- -39.53 --
0.145 0.10 31.20 -- 31.30 -- 59.33 -- -28.03 --
0.193 0.10 29.71 -- 29.81 -- 54.97 -- -25.16 --
0.291 0.10 23.28 -- 23.38 -- 50.04 -- -26.66 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 21: LED LOAD (HLG-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 158 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9870
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 41.70 -- 41.80 -- 88.00 -- -46.20 --


0.097 0.10 40.78 -- 40.88 -- 75.16 -- -34.28 --
0.144 0.10 28.00 -- 28.10 -- 59.61 -- -31.51 --
0.193 0.10 35.70 -- 35.80 -- 54.97 -- -19.17 --
0.240 0.10 31.34 -- 31.44 -- 52.35 -- -20.91 --
0.291 0.10 28.47 -- 28.57 -- 50.04 -- -21.47 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 21: LED LOAD (HLG-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 159 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9879
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 46.74 -- 46.84 -- 88.00 -- -41.16 --


0.048 0.10 37.32 -- 37.42 -- 88.00 -- -50.58 --
0.097 0.10 34.40 -- 34.50 -- 75.16 -- -40.66 --
0.154 0.10 34.05 -- 34.15 -- 57.68 -- -23.53 --
0.189 0.10 28.17 -- 28.27 -- 55.22 -- -26.95 --
0.240 0.10 26.64 -- 26.74 -- 52.35 -- -25.61 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 22: LED LOAD (HLG-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 160 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9878
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 44.23 -- 44.33 -- 88.00 -- -43.67 --


0.048 0.10 35.55 -- 35.65 -- 88.00 -- -52.35 --
0.097 0.10 35.51 -- 35.61 -- 75.16 -- -39.55 --
0.145 0.10 31.24 -- 31.34 -- 59.33 -- -27.99 --
0.193 0.10 29.81 -- 29.91 -- 54.97 -- -25.06 --
0.244 0.10 25.27 -- 25.37 -- 52.15 -- -26.78 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 22: LED LOAD (HLG-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 161 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9877
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 41.66 -- 41.76 -- 88.00 -- -46.24 --


0.097 0.10 40.72 -- 40.82 -- 75.16 -- -34.34 --
0.193 0.10 35.68 -- 35.78 -- 54.97 -- -19.19 --
0.240 0.10 31.41 -- 31.51 -- 52.35 -- -20.84 --
0.291 0.10 28.39 -- 28.49 -- 50.04 -- -21.55 --
0.338 0.10 24.89 -- 24.99 -- 48.24 -- -23.25 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 22: LED LOAD (HLG-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 162 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9880
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 48.64 -- 48.74 -- 88.00 -- -39.26 --


0.048 0.10 37.34 -- 37.44 -- 88.00 -- -50.56 --
0.097 0.10 37.04 -- 37.14 -- 75.16 -- -38.02 --
0.150 0.10 36.41 -- 36.51 -- 58.00 -- -21.49 --
0.205 0.10 33.43 -- 33.53 -- 54.25 -- -20.72 --
0.291 0.10 25.39 -- 25.49 -- 50.04 -- -24.55 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 23: LED LOAD (HLG-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 163 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9881
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 45.45 -- 45.55 -- 88.00 -- -42.45 --


0.048 0.10 35.55 -- 35.65 -- 88.00 -- -52.35 --
0.097 0.10 35.55 -- 35.65 -- 75.16 -- -39.51 --
0.145 0.10 31.26 -- 31.36 -- 59.33 -- -27.97 --
0.193 0.10 30.28 -- 30.38 -- 54.97 -- -24.59 --
0.244 0.10 25.23 -- 25.33 -- 52.15 -- -26.82 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 23: LED LOAD (HLG-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 164 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9882
Temperature: 27.1 OPERATOR: Trevor
Humidity: 51 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 41.68 -- 41.78 -- 88.00 -- -46.22 --


0.097 0.10 40.72 -- 40.82 -- 75.16 -- -34.34 --
0.193 0.10 35.82 -- 35.92 -- 54.97 -- -19.05 --
0.244 0.10 31.45 -- 31.55 -- 52.15 -- -20.60 --
0.291 0.10 28.29 -- 28.39 -- 50.04 -- -21.65 --
0.338 0.10 24.85 -- 24.95 -- 48.24 -- -23.29 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 23: LED LOAD (HLG-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 165 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9891
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 46.78 -- 46.88 -- 88.00 -- -41.12 --


0.048 0.10 38.30 -- 38.40 -- 88.00 -- -49.60 --
0.097 0.10 36.09 -- 36.19 -- 75.16 -- -38.97 --
0.140 0.10 32.45 -- 32.55 -- 60.72 -- -28.17 --
0.205 0.10 33.91 -- 34.01 -- 54.25 -- -20.24 --
11.111 0.10 8.54 -- 8.64 -- 22.00 -- -13.36 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 24: LED LOAD (HLG-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 166 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9890
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 45.72 -- 45.82 -- 88.00 -- -42.18 --


0.048 0.10 39.92 -- 40.02 -- 88.00 -- -47.98 --
0.097 0.10 35.67 -- 35.77 -- 75.16 -- -39.39 --
0.154 0.10 31.64 -- 31.74 -- 57.68 -- -25.94 --
0.193 0.10 29.66 -- 29.76 -- 54.97 -- -25.21 --
7.634 0.10 8.06 -- 8.16 -- 22.00 -- -13.84 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 24: LED LOAD (HLG-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 167 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9889
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 42.13 -- 42.23 -- 88.00 -- -45.77 --


0.048 0.10 45.12 -- 45.22 -- 88.00 -- -42.78 --
0.097 0.10 39.76 -- 39.86 -- 75.16 -- -35.30 --
0.193 0.10 34.56 -- 34.66 -- 54.97 -- -20.31 --
0.240 0.10 29.53 -- 29.63 -- 52.35 -- -22.72 --
14.517 0.10 7.99 -- 8.09 -- 22.00 -- -13.91 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 24: LED LOAD (HLG-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 168 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9892
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 47.63 -- 47.73 -- 88.00 -- -40.27 --


0.048 0.10 38.00 -- 38.10 -- 88.00 -- -49.90 --
0.097 0.10 34.90 -- 35.00 -- 75.16 -- -40.16 --
0.141 0.10 32.69 -- 32.79 -- 60.44 -- -27.65 --
0.193 0.10 31.61 -- 31.71 -- 54.97 -- -23.26 --
0.291 0.10 23.08 -- 23.18 -- 50.04 -- -26.86 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 25: LED LOAD (HLG-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 169 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9893
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 45.45 -- 45.55 -- 88.00 -- -42.45 --


0.048 0.10 36.17 -- 36.27 -- 88.00 -- -51.73 --
0.097 0.10 33.37 -- 33.47 -- 75.16 -- -41.69 --
0.145 0.10 28.22 -- 28.32 -- 59.33 -- -31.01 --
0.193 0.10 30.16 -- 30.26 -- 54.97 -- -24.71 --
0.240 0.10 25.13 -- 25.23 -- 52.35 -- -27.12 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 25: LED LOAD (HLG-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 170 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9894
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 42.21 -- 42.31 -- 88.00 -- -45.69 --


0.097 0.10 40.62 -- 40.72 -- 75.16 -- -34.44 --
0.193 0.10 35.46 -- 35.56 -- 54.97 -- -19.41 --
0.240 0.10 31.04 -- 31.14 -- 52.35 -- -21.21 --
0.291 0.10 28.19 -- 28.29 -- 50.04 -- -21.75 --
0.338 0.10 24.87 -- 24.97 -- 48.24 -- -23.27 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 25: LED LOAD (HLG-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 171 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9903
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 47.71 -- 47.81 -- 88.00 -- -40.19 --


0.048 0.10 37.26 -- 37.36 -- 88.00 -- -50.64 --
0.097 0.10 36.86 -- 36.96 -- 75.16 -- -38.20 --
0.154 0.10 37.04 -- 37.14 -- 57.68 -- -20.54 --
0.189 0.10 27.41 -- 27.51 -- 55.22 -- -27.71 --
0.244 0.10 26.70 -- 26.80 -- 52.15 -- -25.35 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 26: LED LOAD (HLG-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 172 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9902
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 45.25 -- 45.35 -- 88.00 -- -42.65 --


0.048 0.10 35.53 -- 35.63 -- 88.00 -- -52.37 --
0.097 0.10 33.10 -- 33.20 -- 75.16 -- -41.96 --
0.145 0.10 31.11 -- 31.21 -- 59.33 -- -28.12 --
0.193 0.10 29.99 -- 30.09 -- 54.97 -- -24.88 --
0.240 0.10 26.62 -- 26.72 -- 52.35 -- -25.63 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 26: LED LOAD (HLG-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 173 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9901
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 41.58 -- 41.68 -- 88.00 -- -46.32 --


0.097 0.10 38.13 -- 38.23 -- 75.16 -- -36.93 --
0.193 0.10 36.01 -- 36.11 -- 54.97 -- -18.86 --
0.240 0.10 31.92 -- 32.02 -- 52.35 -- -20.33 --
0.291 0.10 29.67 -- 29.77 -- 50.04 -- -20.27 --
0.338 0.10 27.25 -- 27.35 -- 48.24 -- -20.89 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 26: LED LOAD (HLG-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 174 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/102
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.52 -- 37.52 -- 75.16 -- -37.64 --


0.154 0.00 41.48 -- 41.48 -- 57.68 -- -16.20 --
0.181 0.02 32.52 -- 32.54 -- 55.74 -- -23.20 --
0.244 0.06 31.46 -- 31.52 -- 52.15 -- -20.63 --
0.291 0.09 25.90 -- 25.99 -- 50.04 -- -24.05 --
0.338 0.08 21.61 -- 21.69 -- 48.24 -- -26.55 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 27: LED LOAD (HLG-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 175 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/101
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 36.06 -- 36.06 -- 75.16 -- -39.10 --


0.145 0.00 32.12 -- 32.12 -- 59.33 -- -27.21 --
0.193 0.03 31.49 -- 31.52 -- 54.97 -- -23.45 --
0.240 0.06 26.63 -- 26.69 -- 52.35 -- -25.66 --
0.291 0.09 24.35 -- 24.44 -- 50.04 -- -25.60 --
0.338 0.08 21.13 -- 21.21 -- 48.24 -- -27.03 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 27: LED LOAD (HLG-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 176 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/100
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.145 0.00 37.82 -- 37.82 -- 59.33 -- -21.51 --


0.193 0.03 36.23 -- 36.26 -- 54.97 -- -18.71 --
0.244 0.06 31.52 -- 31.58 -- 52.15 -- -20.57 --
0.291 0.09 29.33 -- 29.42 -- 50.04 -- -20.62 --
0.338 0.08 26.35 -- 26.43 -- 48.24 -- -21.81 --
0.388 0.06 23.04 -- 23.10 -- 46.58 -- -23.48 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 27: LED LOAD (HLG-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 177 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9904
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 47.94 -- 48.04 -- 88.00 -- -39.96 --


0.048 0.10 37.16 -- 37.26 -- 88.00 -- -50.74 --
0.097 0.10 34.32 -- 34.42 -- 75.16 -- -40.74 --
0.140 0.10 32.75 -- 32.85 -- 60.72 -- -27.87 --
0.205 0.10 28.98 -- 29.08 -- 54.25 -- -25.17 --
0.244 0.10 27.11 -- 27.21 -- 52.15 -- -24.94 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 28: LED LOAD (HLG-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 178 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9905
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.026 0.10 45.26 -- 45.36 -- 88.00 -- -42.64 --


0.048 0.10 35.19 -- 35.29 -- 88.00 -- -52.71 --
0.097 0.10 35.15 -- 35.25 -- 75.16 -- -39.91 --
0.145 0.10 30.93 -- 31.03 -- 59.33 -- -28.30 --
0.193 0.10 29.24 -- 29.34 -- 54.97 -- -25.63 --
0.291 0.10 22.53 -- 22.63 -- 50.04 -- -27.41 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 28: LED LOAD (HLG-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 179 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLG-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9906
Temperature: 28.1 OPERATOR: Trevor
Humidity: 48 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 41.08 -- 41.18 -- 88.00 -- -46.82 --


0.097 0.10 40.00 -- 40.10 -- 75.16 -- -35.06 --
0.145 0.10 36.77 -- 36.87 -- 59.33 -- -22.46 --
0.193 0.10 34.94 -- 35.04 -- 54.97 -- -19.93 --
0.240 0.10 30.34 -- 30.44 -- 52.35 -- -21.91 --
0.291 0.10 27.88 -- 27.98 -- 50.04 -- -22.06 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 28: LED LOAD (HLG-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 180 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9859
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.32 -- 37.32 -- 75.16 -- -37.84 --


0.128 0.00 35.17 -- 35.17 -- 64.24 -- -29.07 --
0.141 0.00 35.15 -- 35.15 -- 60.44 -- -25.29 --
0.166 0.01 37.76 -- 37.77 -- 56.78 -- -19.01 --
0.205 0.04 35.57 -- 35.61 -- 54.25 -- -18.64 --
0.232 0.05 30.82 -- 30.87 -- 52.76 -- -21.89 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 29: LED LOAD (HLN-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 181 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9860
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 36.02 -- 36.02 -- 75.16 -- -39.14 --


0.154 0.00 36.14 -- 36.14 -- 57.68 -- -21.54 --
0.166 0.01 33.63 -- 33.64 -- 56.78 -- -23.14 --
0.201 0.03 24.24 -- 24.27 -- 54.48 -- -30.21 --
0.244 0.06 26.95 -- 27.01 -- 52.15 -- -25.14 --
0.291 0.09 23.61 -- 23.70 -- 50.04 -- -26.34 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 29: LED LOAD (HLN-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 182 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9861
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 40.82 -- 40.82 -- 75.16 -- -34.34 --


0.145 0.00 37.35 -- 37.35 -- 59.33 -- -21.98 --
0.193 0.03 36.04 -- 36.07 -- 54.97 -- -18.90 --
0.240 0.06 31.79 -- 31.85 -- 52.35 -- -20.50 --
0.291 0.09 28.80 -- 28.89 -- 50.04 -- -21.15 --
0.338 0.08 25.44 -- 25.52 -- 48.24 -- -22.72 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 29: LED LOAD (HLN-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 183 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9856
Temperature: 28.0 OPERATOR: OWEN
Humidity: 50 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.10 39.33 -- 39.43 -- 88.00 -- -48.57 --


0.097 0.10 37.02 -- 37.12 -- 75.16 -- -38.04 --
0.145 0.10 31.88 -- 31.98 -- 59.33 -- -27.35 --
0.181 0.10 31.74 -- 31.84 -- 55.74 -- -23.90 --
0.248 0.10 25.44 -- 25.54 -- 51.96 -- -26.42 --
0.291 0.10 27.12 -- 27.22 -- 50.04 -- -22.82 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 30: LED LOAD (HLN-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 184 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9857
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 35.70 -- 35.70 -- 75.16 -- -39.46 --


0.145 0.00 31.65 -- 31.65 -- 59.33 -- -27.68 --
0.166 0.01 31.40 -- 31.41 -- 56.78 -- -25.37 --
0.193 0.03 31.13 -- 31.16 -- 54.97 -- -23.81 --
0.244 0.06 26.35 -- 26.41 -- 52.15 -- -25.74 --
0.291 0.09 23.68 -- 23.77 -- 50.04 -- -26.27 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 30: LED LOAD (HLN-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 185 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9858
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 40.59 -- 40.59 -- 75.16 -- -34.57 --


0.145 0.00 37.33 -- 37.33 -- 59.33 -- -22.00 --
0.193 0.03 35.89 -- 35.92 -- 54.97 -- -19.05 --
0.244 0.06 31.28 -- 31.34 -- 52.15 -- -20.81 --
0.287 0.09 25.52 -- 25.61 -- 50.20 -- -24.59 --
0.338 0.08 25.33 -- 25.41 -- 48.24 -- -22.83 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 30: LED LOAD (HLN-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 186 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9853
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.06 -- 37.06 -- 75.16 -- -38.10 --


0.128 0.00 29.25 -- 29.25 -- 64.24 -- -34.99 --
0.141 0.00 30.57 -- 30.57 -- 60.44 -- -29.87 --
0.166 0.01 37.08 -- 37.09 -- 56.78 -- -19.69 --
0.177 0.02 33.83 -- 33.85 -- 56.01 -- -22.16 --
0.193 0.03 30.47 -- 30.50 -- 54.97 -- -24.47 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 31: LED LOAD (HLN-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 187 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9854
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 35.53 -- 35.53 -- 75.16 -- -39.63 --


0.154 0.00 34.90 -- 34.90 -- 57.68 -- -22.78 --
0.170 0.01 28.74 -- 28.75 -- 56.50 -- -27.75 --
0.193 0.03 31.46 -- 31.49 -- 54.97 -- -23.48 --
0.244 0.06 26.76 -- 26.82 -- 52.15 -- -25.33 --
0.291 0.09 23.31 -- 23.40 -- 50.04 -- -26.64 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 31: LED LOAD (HLN-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 188 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9855
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 40.38 -- 40.38 -- 75.16 -- -34.78 --


0.145 0.00 37.20 -- 37.20 -- 59.33 -- -22.13 --
0.193 0.03 35.74 -- 35.77 -- 54.97 -- -19.20 --
0.240 0.06 31.31 -- 31.37 -- 52.35 -- -20.98 --
0.291 0.09 28.54 -- 28.63 -- 50.04 -- -21.41 --
0.338 0.08 25.15 -- 25.23 -- 48.24 -- -23.01 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 31: LED LOAD (HLN-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 189 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9850
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.46 -- 37.46 -- 75.16 -- -37.70 --


0.141 0.00 33.83 -- 33.83 -- 60.44 -- -26.61 --
0.166 0.01 37.84 -- 37.85 -- 56.78 -- -18.93 --
0.193 0.03 36.35 -- 36.38 -- 54.97 -- -18.59 --
0.255 0.07 30.87 -- 30.94 -- 51.62 -- -20.68 --
0.291 0.09 26.18 -- 26.27 -- 50.04 -- -23.77 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 32: LED LOAD (HLN-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 190 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9851
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 35.97 -- 35.97 -- 75.16 -- -39.19 --


0.145 0.00 32.16 -- 32.16 -- 59.33 -- -27.17 --
0.166 0.01 33.06 -- 33.07 -- 56.78 -- -23.71 --
0.193 0.03 32.20 -- 32.23 -- 54.97 -- -22.74 --
0.240 0.06 26.99 -- 27.05 -- 52.35 -- -25.30 --
0.291 0.09 24.56 -- 24.65 -- 50.04 -- -25.39 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 32: LED LOAD (HLN-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 191 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9852
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.150 0.00 32.17 -- 32.17 -- 58.00 -- -25.83 --


0.193 0.03 36.53 -- 36.56 -- 54.97 -- -18.41 --
0.244 0.06 31.95 -- 32.01 -- 52.15 -- -20.14 --
0.291 0.09 29.41 -- 29.50 -- 50.04 -- -20.54 --
0.338 0.08 26.43 -- 26.51 -- 48.24 -- -21.73 --
0.388 0.06 23.26 -- 23.32 -- 46.58 -- -23.26 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 32: LED LOAD (HLN-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 192 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9847
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 35.23 -- 35.23 -- 75.16 -- -39.93 --


0.128 0.00 29.84 -- 29.84 -- 64.24 -- -34.40 --
0.141 0.00 33.67 -- 33.67 -- 60.44 -- -26.77 --
0.170 0.01 34.40 -- 34.41 -- 56.50 -- -22.09 --
0.255 0.07 32.90 -- 32.97 -- 51.62 -- -18.65 --
0.306 0.10 25.00 -- 25.10 -- 49.43 -- -24.33 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 33: LED LOAD (HLN-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 193 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9848
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 36.04 -- 36.04 -- 75.16 -- -39.12 --


0.150 0.00 34.41 -- 34.41 -- 58.00 -- -23.59 --
0.193 0.03 32.08 -- 32.11 -- 54.97 -- -22.86 --
0.240 0.06 26.66 -- 26.72 -- 52.35 -- -25.63 --
0.291 0.09 23.61 -- 23.70 -- 50.04 -- -26.34 --
0.338 0.08 20.29 -- 20.37 -- 48.24 -- -27.87 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 33: LED LOAD (HLN-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 194 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9849
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 40.82 -- 40.82 -- 75.16 -- -34.34 --


0.150 0.00 31.62 -- 31.62 -- 58.00 -- -26.38 --
0.193 0.03 36.08 -- 36.11 -- 54.97 -- -18.86 --
0.240 0.06 31.89 -- 31.95 -- 52.35 -- -20.40 --
0.291 0.09 28.73 -- 28.82 -- 50.04 -- -21.22 --
0.338 0.08 25.53 -- 25.61 -- 48.24 -- -22.63 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 33: LED LOAD (HLN-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 195 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9844
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 36.86 -- 36.86 -- 75.16 -- -38.30 --


0.145 0.00 32.75 -- 32.75 -- 59.33 -- -26.58 --
0.158 0.01 35.04 -- 35.05 -- 57.38 -- -22.33 --
0.170 0.01 32.69 -- 32.70 -- 56.50 -- -23.80 --
0.193 0.03 31.99 -- 32.02 -- 54.97 -- -22.95 --
0.228 0.05 28.31 -- 28.36 -- 52.97 -- -24.61 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 34: LED LOAD (HLN-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 196 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9845
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 35.44 -- 35.44 -- 75.16 -- -39.72 --


0.145 0.00 31.65 -- 31.65 -- 59.33 -- -27.68 --
0.166 0.01 32.02 -- 32.03 -- 56.78 -- -24.75 --
0.193 0.03 31.49 -- 31.52 -- 54.97 -- -23.45 --
0.240 0.06 26.17 -- 26.23 -- 52.35 -- -26.12 --
0.291 0.09 23.66 -- 23.75 -- 50.04 -- -26.29 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 34: LED LOAD (HLN-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 197 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9846
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 40.36 -- 40.36 -- 75.16 -- -34.80 --


0.145 0.00 37.28 -- 37.28 -- 59.33 -- -22.05 --
0.193 0.03 35.78 -- 35.81 -- 54.97 -- -19.16 --
0.244 0.06 31.33 -- 31.39 -- 52.15 -- -20.76 --
0.291 0.09 28.44 -- 28.53 -- 50.04 -- -21.51 --
0.338 0.08 24.95 -- 25.03 -- 48.24 -- -23.21 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 34: LED LOAD (HLN-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 198 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9841
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.13 -- 37.13 -- 75.16 -- -38.03 --


0.141 0.00 36.18 -- 36.18 -- 60.44 -- -24.26 --
0.166 0.01 39.08 -- 39.09 -- 56.78 -- -17.69 --
0.193 0.03 35.93 -- 35.96 -- 54.97 -- -19.01 --
0.244 0.06 33.30 -- 33.36 -- 52.15 -- -18.79 --
0.295 0.10 25.59 -- 25.69 -- 49.87 -- -24.18 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 35: LED LOAD (HLN-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 199 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9842
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 36.10 -- 36.10 -- 75.16 -- -39.06 --


0.141 0.00 27.36 -- 27.36 -- 60.44 -- -33.08 --
0.177 0.02 28.24 -- 28.26 -- 56.01 -- -27.75 --
0.193 0.03 31.53 -- 31.56 -- 54.97 -- -23.41 --
0.244 0.06 27.01 -- 27.07 -- 52.15 -- -25.08 --
0.291 0.09 24.19 -- 24.28 -- 50.04 -- -25.76 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 35: LED LOAD (HLN-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 200 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9843
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.145 0.00 37.29 -- 37.29 -- 59.33 -- -22.04 --


0.193 0.03 36.29 -- 36.32 -- 54.97 -- -18.65 --
0.240 0.06 31.99 -- 32.05 -- 52.35 -- -20.30 --
0.291 0.09 29.19 -- 29.28 -- 50.04 -- -20.76 --
0.338 0.08 26.05 -- 26.13 -- 48.24 -- -22.11 --
0.388 0.06 23.18 -- 23.24 -- 46.58 -- -23.34 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 35: LED LOAD (HLN-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 201 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9838
Temperature: 18.0 OPERATOR: OWEN
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.00 36.59 -- 36.59 -- 88.00 -- -51.41 --


0.097 0.00 34.05 -- 34.05 -- 75.16 -- -41.11 --
0.145 0.09 31.82 -- 31.91 -- 59.33 -- -27.42 --
0.193 0.10 35.73 -- 35.83 -- 54.97 -- -19.14 --
0.228 0.10 34.70 -- 34.80 -- 52.97 -- -18.17 --
0.287 0.10 26.22 -- 26.32 -- 50.20 -- -23.88 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 36: LED LOAD (HLN-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 202 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9839
Temperature: 18.0 OPERATOR: OWEN
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.048 0.00 35.33 -- 35.33 -- 88.00 -- -52.67 --


0.097 0.00 32.95 -- 32.95 -- 75.16 -- -42.21 --
0.145 0.09 31.29 -- 31.38 -- 59.33 -- -27.95 --
0.166 0.10 33.75 -- 33.85 -- 56.78 -- -22.93 --
0.193 0.10 32.49 -- 32.59 -- 54.97 -- -22.38 --
0.244 0.10 28.14 -- 28.24 -- 52.15 -- -23.91 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 36: LED LOAD (HLN-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 203 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9840
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 40.38 -- 40.38 -- 75.16 -- -34.78 --


0.145 0.00 37.20 -- 37.20 -- 59.33 -- -22.13 --
0.193 0.03 35.74 -- 35.77 -- 54.97 -- -19.20 --
0.240 0.06 31.31 -- 31.37 -- 52.35 -- -20.98 --
0.291 0.09 28.54 -- 28.63 -- 50.04 -- -21.41 --
0.338 0.08 25.15 -- 25.23 -- 48.24 -- -23.01 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 36: LED LOAD (HLN-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 204 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9835
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.29 -- 37.29 -- 75.16 -- -37.87 --


0.128 0.00 34.12 -- 34.12 -- 64.24 -- -30.12 --
0.140 0.00 36.26 -- 36.26 -- 60.72 -- -24.46 --
0.177 0.02 34.48 -- 34.50 -- 56.01 -- -21.51 --
0.193 0.03 34.63 -- 34.66 -- 54.97 -- -20.31 --
0.255 0.07 33.44 -- 33.51 -- 51.62 -- -18.11 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 37: LED LOAD (HLN-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 205 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9836
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 36.12 -- 36.12 -- 75.16 -- -39.04 --


0.145 0.00 31.83 -- 31.83 -- 59.33 -- -27.50 --
0.166 0.01 33.26 -- 33.27 -- 56.78 -- -23.51 --
0.177 0.02 28.78 -- 28.80 -- 56.01 -- -27.21 --
0.197 0.03 27.31 -- 27.34 -- 54.72 -- -27.38 --
0.244 0.06 27.26 -- 27.32 -- 52.15 -- -24.83 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 37: LED LOAD (HLN-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 206 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLN-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/9837
Temperature: 23.4 OPERATOR: OWEN
Humidity: 59 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 41.09 -- 41.09 -- 75.16 -- -34.07 --


0.145 0.00 37.50 -- 37.50 -- 59.33 -- -21.83 --
0.193 0.03 36.29 -- 36.32 -- 54.97 -- -18.65 --
0.244 0.06 32.05 -- 32.11 -- 52.15 -- -20.04 --
0.291 0.09 29.25 -- 29.34 -- 50.04 -- -20.70 --
0.338 0.08 25.77 -- 25.85 -- 48.24 -- -22.39 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 37: LED LOAD (HLN-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 207 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 1
CLIENT: MEAN WELL DISTANCE:
MODEL: HLP-80H-48 Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/105
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 37.21 -- 37.21 -- 75.16 -- -37.95 --


0.140 0.00 35.05 -- 35.05 -- 60.72 -- -25.67 --
0.166 0.01 37.68 -- 37.69 -- 56.78 -- -19.09 --
0.193 0.03 34.87 -- 34.90 -- 54.97 -- -20.07 --
0.244 0.06 32.23 -- 32.29 -- 52.15 -- -19.86 --
0.298 0.10 23.86 -- 23.96 -- 49.75 -- -25.79 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 38: LED LOAD (HLP-80H-48) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 208 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 2
CLIENT: MEAN WELL DISTANCE:
MODEL: HLP-80H-48 Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/104
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.097 0.00 35.95 -- 35.95 -- 75.16 -- -39.21 --


0.154 0.00 35.44 -- 35.44 -- 57.68 -- -22.24 --
0.166 0.01 31.85 -- 31.86 -- 56.78 -- -24.92 --
0.193 0.03 31.51 -- 31.54 -- 54.97 -- -23.43 --
0.244 0.06 26.79 -- 26.85 -- 52.15 -- -25.30 --
0.291 0.09 24.27 -- 24.36 -- 50.04 -- -25.68 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 38: LED LOAD (HLP-80H-48) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 209 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Loop 3
CLIENT: MEAN WELL DISTANCE:
MODEL: HLP-80H-48 Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/103
Temperature: 24.0 OPERATOR: Trevor
Humidity: 55 % TEST SITE: Conduction1

Frequency Factor Meter Reading dB (A) Emission Level dB (A) Limits dB (A) Margin (dB)

(MHz) (dB) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average

0.150 0.00 31.81 -- 31.81 -- 58.00 -- -26.19 --


0.193 0.03 36.19 -- 36.22 -- 54.97 -- -18.75 --
0.244 0.06 31.58 -- 31.64 -- 52.15 -- -20.51 --
0.291 0.09 28.99 -- 29.08 -- 50.04 -- -20.96 --
0.338 0.08 26.11 -- 26.19 -- 48.24 -- -22.05 --
0.388 0.06 23.10 -- 23.16 -- 46.58 -- -23.42 --
Remark:
1. All readings are Quasi-Peak values.
2. Factor = Insertion Loss + Cable Loss.
LIMIT: EN55015 LT.LMT

Test Mode: Mode 38: LED LOAD (HLP-80H-48) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 210 of 385

4 Radiated Disturbance (30 MHz to 300 MHz) Measurement

4.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

EMI Test Receiver Rohde & Schwarz ESCS30 100127 2011/09/08

Biconical Antenna Schwarzbeck VHA 9103 2484 2011/10/08

Log Antenna Schwarzbeck UHALP 9108 A 0765 2011/10/08

Pre-Amplifier Agilent 8447D 1937A01903 2011/12/06

RF Cable PACIFIC CBL41 CBL41 2011/11/18


Note: The above equipments are within the valid calibration period.

4.2 Block Diagram of Test Configuration


Measurement Frequency under 1GHz
10 m or 3m

RF Cable

4m

EUT

1m Test table & Turntable 80 cm


Pre-Amplifier

EMI Test Receiver Ground Plane

4.3 Radiated Limits


Frequency range Quasi-Peak
(MHz) dB(V /m)
30 ~ 230 30.0
230 ~ 300 37.0

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 211 of 385

4.4 Instrument Configuration


4.4.1 Set the EMI test receiver frequency range from 30 MHz to 300 MHz.
4.4.2 Set the EMI test receiver bandwidth at 120 kHz.
4.4.3 Set the EMI test receiver detector as Quasi-Peak (Q.P.).

4.5 Configuration of Measurement


4.5.1 The EUT was placed on a non-conductive table whose total height equaled 80cm. The
turntable can rotate 360 degree to determine the position of the maximum emission level.
4.5.2 The EUT was set 10 meters away from the receiving antenna that was mounted on a
non-conductive mast. The antenna can move up and down between 1 to 4 meters to find out
the maximum emission level.
4.5.3 The initial testing identified the frequency that has the highest disturbance relative to the
limit while operating the EUT in typical modes of operation and cable positions in a test
setup representative of typical system configuration.
4.5.4 The identification of the frequency of highest emission with respect to the limit was found by
investigating emissions at a number of significant frequencies. The probable frequency of
maximum emission had been found and that the associated cable and EUT configuration
and mode of operation had been identified.

4.6 Test Result


PASS.
The final test data is shown as following pages.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 212 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7151
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.400 ** -17.92 39.40 21.48 30.00 -8.52


66.400 ** -21.66 41.80 20.14 30.00 -9.86
85.300 ** -20.39 40.70 20.31 30.00 -9.69
110.000 ** -16.06 36.50 20.44 30.00 -9.56
152.000 ** -12.65 31.60 18.95 30.00 -11.05
189.400 ** -10.96 30.40 19.44 30.00 -10.56
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 1: LED LOAD (HLG-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 213 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7152
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

53.500 ** -18.68 39.50 20.82 30.00 -9.18


67.100 ** -21.76 41.10 19.34 30.00 -10.66
87.000 ** -20.12 40.20 20.08 30.00 -9.92
109.500 ** -16.14 36.40 20.26 30.00 -9.74
153.500 ** -12.56 31.50 18.94 30.00 -11.06
186.000 ** -11.06 30.40 19.34 30.00 -10.66
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 1: LED LOAD (HLG-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 214 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7156
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.400 ** -18.28 39.40 21.12 30.00 -8.88


67.400 ** -21.81 41.50 19.69 30.00 -10.31
85.400 ** -20.37 40.30 19.93 30.00 -10.07
110.600 ** -15.98 36.50 20.52 30.00 -9.48
151.000 ** -12.71 31.50 18.79 30.00 -11.21
186.400 ** -11.05 30.40 19.35 30.00 -10.65
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 2: LED LOAD (HLG-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 215 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7155
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.400 ** -18.28 39.40 21.12 30.00 -8.88


68.400 ** -21.97 41.60 19.63 30.00 -10.37
85.400 ** -20.37 40.60 20.23 30.00 -9.77
110.500 ** -16.00 36.50 20.50 30.00 -9.50
156.400 ** -12.37 31.40 19.03 30.00 -10.97
190.500 ** -10.93 30.60 19.67 30.00 -10.33
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 2: LED LOAD (HLG-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 216 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7159
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.88 39.40 21.52 30.00 -8.48


67.500 ** -21.82 41.60 19.78 30.00 -10.22
85.500 ** -20.35 40.50 20.15 30.00 -9.85
110.500 ** -16.00 36.50 20.50 30.00 -9.50
156.300 ** -12.37 31.40 19.03 30.00 -10.97
187.200 ** -11.03 30.50 19.47 30.00 -10.53
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 3: LED LOAD (HLG-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 217 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7160
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.400 ** -18.28 39.60 21.32 30.00 -8.68


68.400 ** -21.97 41.20 19.23 30.00 -10.77
86.400 ** -20.21 40.50 20.29 30.00 -9.71
110.500 ** -16.00 36.40 20.40 30.00 -9.60
157.200 ** -12.31 31.50 19.19 30.00 -10.81
186.400 ** -11.05 30.40 19.35 30.00 -10.65
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 3: LED LOAD (HLG-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 218 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7260
Temperature: 79.9 OPERATOR: Roy
Humidity: 55 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

44.000 ** -15.29 37.63 22.34 30.00 -7.66


65.000 ** -21.44 41.56 20.12 30.00 -9.88
86.000 ** -20.28 42.50 22.22 30.00 -7.78
115.000 ** -15.46 37.20 21.74 30.00 -8.26
145.000 ** -13.05 35.60 22.55 30.00 -7.45
205.000 ** -10.69 32.10 21.41 30.00 -8.59
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 4: LED LOAD (HLG-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 219 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7259
Temperature: 79.9 OPERATOR: Roy
Humidity: 55 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

48.500 ** -16.91 38.10 21.19 30.00 -8.81


74.100 ** -21.97 42.50 20.53 30.00 -9.47
83.200 ** -20.76 43.50 22.74 30.00 -7.26
121.200 ** -14.76 37.21 22.45 30.00 -7.55
167.000 ** -11.80 34.23 22.43 30.00 -7.57
193.000 ** -10.90 33.21 22.31 30.00 -7.69
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 4: LED LOAD (HLG-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 220 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7148
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

50.300 ** -17.52 38.60 21.08 30.00 -8.92


73.800 ** -21.99 41.30 19.31 30.00 -10.69
83.500 ** -20.71 40.60 19.89 30.00 -10.11
112.800 ** -15.72 36.80 21.08 30.00 -8.92
150.600 ** -12.74 31.50 18.76 30.00 -11.24
195.400 ** -10.86 30.60 19.74 30.00 -10.26
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 5: LED LOAD (HLG-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 221 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7147
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.200 ** -17.84 38.50 20.66 30.00 -9.34


67.100 ** -21.76 41.60 19.84 30.00 -10.16
85.600 ** -20.34 40.50 20.16 30.00 -9.84
110.600 ** -15.98 36.50 20.52 30.00 -9.48
157.200 ** -12.31 30.90 18.59 30.00 -11.41
192.800 ** -10.90 31.00 20.10 30.00 -9.90
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 5: LED LOAD (HLG-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 222 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7263
Temperature: 79.9 OPERATOR: Roy
Humidity: 55 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

48.000 ** -16.74 38.50 21.76 30.00 -8.24


75.000 ** -21.92 42.10 20.18 30.00 -9.82
86.540 ** -20.19 41.50 21.31 30.00 -8.69
115.000 ** -15.46 36.10 20.64 30.00 -9.36
145.000 ** -13.05 34.42 21.37 30.00 -8.63
205.250 ** -10.69 32.40 21.71 30.00 -8.29
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 6: LED LOAD (HLG-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 223 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7264
Temperature: 79.9 OPERATOR: Roy
Humidity: 55 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

43.200 ** -14.93 37.54 22.61 30.00 -7.39


55.240 ** -19.26 38.20 18.94 30.00 -11.06
86.000 ** -20.28 41.20 20.92 30.00 -9.08
115.000 ** -15.46 37.21 21.75 30.00 -8.25
141.000 ** -13.26 36.21 22.95 30.00 -7.05
154.000 ** -12.52 34.65 22.13 30.00 -7.87
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 6: LED LOAD (HLG-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 224 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7164
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.88 39.40 21.52 30.00 -8.48


67.500 ** -21.82 41.20 19.38 30.00 -10.62
85.450 ** -20.37 40.50 20.13 30.00 -9.87
110.500 ** -16.00 36.40 20.40 30.00 -9.60
153.500 ** -12.56 31.50 18.94 30.00 -11.06
186.500 ** -11.05 30.40 19.35 30.00 -10.65
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 7: LED LOAD (HLG-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 225 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7163
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.400 ** -18.28 39.40 21.12 30.00 -8.88


67.500 ** -21.82 41.20 19.38 30.00 -10.62
86.400 ** -20.21 40.50 20.29 30.00 -9.71
116.500 ** -15.28 36.50 21.22 30.00 -8.78
153.400 ** -12.56 31.20 18.64 30.00 -11.36
187.500 ** -11.02 30.50 19.48 30.00 -10.52
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 7: LED LOAD (HLG-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 226 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7207
Temperature: 11.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.700 ** -18.02 39.50 21.48 30.00 -8.52


66.800 ** -21.72 41.30 19.58 30.00 -10.42
86.300 ** -20.23 41.00 20.77 30.00 -9.23
121.600 ** -14.72 35.70 20.98 30.00 -9.02
163.500 ** -11.97 30.90 18.93 30.00 -11.07
199.200 ** -10.81 31.20 20.39 30.00 -9.61
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 8: LED LOAD (HLG-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 227 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7204
Temperature: 11.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.300 ** -18.25 39.60 21.35 30.00 -8.65


72.400 ** -22.07 40.50 18.43 30.00 -11.57
85.400 ** -20.37 40.60 20.23 30.00 -9.77
118.400 ** -15.06 36.50 21.44 30.00 -8.56
148.200 ** -12.88 31.60 18.72 30.00 -11.28
195.800 ** -10.86 30.60 19.74 30.00 -10.26
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 8: LED LOAD (HLG-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 228 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7167
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.600 ** -18.35 39.40 21.05 30.00 -8.95


67.500 ** -21.82 41.50 19.68 30.00 -10.32
86.500 ** -20.19 40.56 20.37 30.00 -9.63
110.500 ** -16.00 36.50 20.50 30.00 -9.50
153.300 ** -12.57 31.50 18.93 30.00 -11.07
189.300 ** -10.96 30.50 19.54 30.00 -10.46
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 9: LED LOAD (HLG-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 229 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7168
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.300 ** -18.25 39.40 21.15 30.00 -8.85


68.500 ** -21.98 41.60 19.62 30.00 -10.38
85.600 ** -20.34 40.50 20.16 30.00 -9.84
112.200 ** -15.80 36.50 20.70 30.00 -9.30
153.000 ** -12.59 31.60 19.01 30.00 -10.99
186.500 ** -11.05 30.40 19.35 30.00 -10.65
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 9: LED LOAD (HLG-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 230 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6774
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.50 21.65 30.00 -8.35


69.800 ** -22.28 40.80 18.52 30.00 -11.48
85.600 ** -20.10 40.30 20.20 30.00 -9.80
116.300 ** -15.37 36.80 21.43 30.00 -8.57
156.300 ** -12.47 30.80 18.33 30.00 -11.67
195.700 ** -11.02 30.40 19.38 30.00 -10.62
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 10: LED LOAD (HLN-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 231 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-12A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6773
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.200 ** -17.82 39.00 21.18 30.00 -8.82


65.400 ** -21.61 44.80 23.19 30.00 -6.81
85.400 ** -20.15 40.80 20.65 30.00 -9.35
110.600 ** -15.99 36.50 20.51 30.00 -9.49
133.000 ** -13.72 33.80 20.08 30.00 -9.92
195.600 ** -11.02 30.70 19.68 30.00 -10.32
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 10: LED LOAD (HLN-80H-12A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 232 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6777
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.400 ** -18.23 39.50 21.27 30.00 -8.73


72.500 ** -22.12 40.60 18.48 30.00 -11.52
85.900 ** -20.04 40.30 20.26 30.00 -9.74
112.600 ** -15.77 36.80 21.03 30.00 -8.97
155.200 ** -12.54 30.70 18.16 30.00 -11.84
192.300 ** -11.03 30.50 19.47 30.00 -10.53
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 11: LED LOAD (HLN-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 233 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-15A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6778
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

64.700 ** -21.45 45.00 23.55 30.00 -6.45


75.600 ** -21.84 41.30 19.46 30.00 -10.54
86.200 ** -19.98 40.50 20.52 30.00 -9.48
135.700 ** -13.56 35.10 21.54 30.00 -8.46
161.300 ** -12.17 30.50 18.33 30.00 -11.67
195.800 ** -11.02 30.40 19.38 30.00 -10.62
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 11: LED LOAD (HLN-80H-15A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 234 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6782
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

50.800 ** -17.68 39.20 21.52 30.00 -8.48


72.800 ** -22.09 40.60 18.51 30.00 -11.49
85.400 ** -20.15 40.50 20.35 30.00 -9.65
110.600 ** -15.99 36.20 20.21 30.00 -9.79
153.600 ** -12.64 30.50 17.86 30.00 -12.14
195.600 ** -11.02 30.20 19.18 30.00 -10.82
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 12: LED LOAD (HLN-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 235 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-20A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6781
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.200 ** -17.82 39.50 21.68 30.00 -8.32


66.000 ** -21.69 42.60 20.91 30.00 -9.09
85.400 ** -20.15 40.30 20.15 30.00 -9.85
111.000 ** -15.95 36.20 20.25 30.00 -9.75
137.300 ** -13.47 33.60 20.13 30.00 -9.87
195.700 ** -11.02 30.50 19.48 30.00 -10.52
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 12: LED LOAD (HLN-80H-20A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 236 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6785
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.600 ** -18.30 39.40 21.10 30.00 -8.90


72.500 ** -22.12 40.50 18.38 30.00 -11.62
85.400 ** -20.15 40.30 20.15 30.00 -9.85
110.600 ** -15.99 36.50 20.51 30.00 -9.49
152.800 ** -12.70 30.40 17.70 30.00 -12.30
195.600 ** -11.02 30.40 19.38 30.00 -10.62
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 13: LED LOAD (HLN-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 237 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-24A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6786
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.50 21.65 30.00 -8.35


67.900 ** -21.99 44.20 22.21 30.00 -7.79
85.600 ** -20.10 40.30 20.20 30.00 -9.80
110.500 ** -16.00 36.80 20.80 30.00 -9.20
135.200 ** -13.59 34.60 21.01 30.00 -8.99
195.600 ** -11.02 30.70 19.68 30.00 -10.32
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 13: LED LOAD (HLN-80H-24A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 238 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6790
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.50 21.65 30.00 -8.35


72.500 ** -22.12 40.60 18.48 30.00 -11.52
85.400 ** -20.15 40.30 20.15 30.00 -9.85
110.600 ** -15.99 36.50 20.51 30.00 -9.49
157.000 ** -12.43 30.60 18.17 30.00 -11.83
195.400 ** -11.01 30.40 19.39 30.00 -10.61
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 14: LED LOAD (HLN-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 239 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-30A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6789
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.50 21.65 30.00 -8.35


66.500 ** -21.77 45.80 24.03 30.00 -5.97
85.600 ** -20.10 40.50 20.40 30.00 -9.60
109.900 ** -16.07 36.50 20.43 30.00 -9.57
135.700 ** -13.56 35.00 21.44 30.00 -8.56
196.500 ** -11.01 30.50 19.49 30.00 -10.51
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 14: LED LOAD (HLN-80H-30A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 240 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6793
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

55.300 ** -19.18 39.50 20.32 30.00 -9.68


72.800 ** -22.09 40.50 18.41 30.00 -11.59
86.200 ** -19.98 40.50 20.52 30.00 -9.48
109.900 ** -16.07 36.20 20.13 30.00 -9.87
153.600 ** -12.64 30.80 18.16 30.00 -11.84
195.600 ** -11.02 30.40 19.38 30.00 -10.62
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 15: LED LOAD (HLN-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 241 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-36A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6794
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.600 ** -18.30 39.40 21.10 30.00 -8.90


65.900 ** -21.68 43.90 22.22 30.00 -7.78
85.700 ** -20.08 40.60 20.52 30.00 -9.48
110.800 ** -15.97 36.20 20.23 30.00 -9.77
139.000 ** -13.37 33.60 20.23 30.00 -9.77
194.800 ** -11.02 30.50 19.48 30.00 -10.52
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 15: LED LOAD (HLN-80H-36A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 242 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6798
Temperature: 23.8 OPERATOR: Wade
Humidity: 50 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.300 ** -18.20 39.20 21.00 30.00 -9.00


65.000 ** -21.54 40.50 18.96 30.00 -11.04
86.400 ** -19.93 40.30 20.37 30.00 -9.63
110.600 ** -15.99 36.40 20.41 30.00 -9.59
136.300 ** -13.52 33.80 20.28 30.00 -9.72
190.300 ** -11.04 30.40 19.36 30.00 -10.64
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 16: LED LOAD (HLN-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 243 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-42A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6797
Temperature: 23.8 OPERATOR: Wade
Humidity: 50 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.400 ** -18.23 39.00 20.77 30.00 -9.23


66.000 ** -21.69 43.50 21.81 30.00 -8.19
86.200 ** -19.98 40.80 20.82 30.00 -9.18
110.600 ** -15.99 36.50 20.51 30.00 -9.49
136.000 ** -13.54 35.70 22.16 30.00 -7.84
194.800 ** -11.02 30.70 19.68 30.00 -10.32
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 16: LED LOAD (HLN-80H-42A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 244 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6801
Temperature: 23.8 OPERATOR: Wade
Humidity: 50 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.400 ** -18.23 39.00 20.77 30.00 -9.23


65.500 ** -21.61 41.00 19.39 30.00 -10.61
85.900 ** -20.04 40.30 20.26 30.00 -9.74
109.900 ** -16.07 36.40 20.33 30.00 -9.67
138.300 ** -13.41 33.70 20.29 30.00 -9.71
191.800 ** -11.03 30.60 19.57 30.00 -10.43
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 17: LED LOAD (HLN-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 245 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-48A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6802
Temperature: 23.8 OPERATOR: Wade
Humidity: 50 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.100 ** -18.13 39.30 21.17 30.00 -8.83


64.300 ** -21.34 44.50 23.16 30.00 -6.84
86.200 ** -19.98 40.50 20.52 30.00 -9.48
110.600 ** -15.99 36.50 20.51 30.00 -9.49
136.500 ** -13.51 34.30 20.79 30.00 -9.21
191.500 ** -11.03 30.60 19.57 30.00 -10.43
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 17: LED LOAD (HLN-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 246 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6806
Temperature: 23.8 OPERATOR: Wade
Humidity: 50 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.40 21.55 30.00 -8.45


66.100 ** -21.71 41.20 19.49 30.00 -10.51
85.900 ** -20.04 40.40 20.36 30.00 -9.64
109.900 ** -16.07 36.30 20.23 30.00 -9.77
126.100 ** -14.31 34.20 19.89 30.00 -10.11
190.600 ** -11.04 30.50 19.46 30.00 -10.54
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 18: LED LOAD (HLN-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 247 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-54A Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/6805
Temperature: 23.8 OPERATOR: Wade
Humidity: 50 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.40 21.55 30.00 -8.45


66.150 ** -21.72 44.10 22.38 30.00 -7.62
86.000 ** -20.02 40.50 20.48 30.00 -9.52
109.900 ** -16.07 36.50 20.43 30.00 -9.57
126.700 ** -14.25 37.80 23.55 30.00 -6.45
190.600 ** -11.04 30.80 19.76 30.00 -10.24
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 18: LED LOAD (HLN-80H-54A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 248 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLP-80H-48 Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7255
Temperature: 79.9 OPERATOR: Roy
Humidity: 55 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

54.000 ** -18.86 38.00 19.14 30.00 -10.86


75.200 ** -21.90 42.30 20.40 30.00 -9.60
84.230 ** -20.57 41.56 20.99 30.00 -9.01
115.000 ** -15.46 36.57 21.11 30.00 -8.89
156.320 ** -12.37 34.20 21.83 30.00 -8.17
207.000 ** -10.65 33.20 22.55 30.00 -7.45
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 19: LED LOAD (HLP-80H-48) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 249 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLP-80H-48 Serial No.:
RATING: 230V/50Hz FILE/DATA#: MEAN WELL.emi/7256
Temperature: 79.9 OPERATOR: Roy
Humidity: 55 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

53.100 ** -18.53 39.20 20.67 30.00 -9.33


75.240 ** -21.89 42.40 20.51 30.00 -9.49
84.250 ** -20.58 41.50 20.92 30.00 -9.08
115.000 ** -15.46 38.10 22.64 30.00 -7.36
146.000 ** -12.99 35.45 22.46 30.00 -7.54
198.000 ** -10.83 31.20 20.37 30.00 -9.63
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 19: LED LOAD (HLP-80H-48) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 250 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7150
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.300 ** -18.25 39.50 21.25 30.00 -8.75


73.500 ** -22.01 41.30 19.29 30.00 -10.71
83.600 ** -20.68 40.60 19.92 30.00 -10.08
109.400 ** -16.17 36.10 19.93 30.00 -10.07
150.300 ** -12.76 31.50 18.74 30.00 -11.26
186.400 ** -11.05 30.50 19.45 30.00 -10.55
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 20: LED LOAD (HLG-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 251 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7153
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.300 ** -18.25 39.50 21.25 30.00 -8.75


67.500 ** -21.82 41.60 19.78 30.00 -10.22
86.100 ** -20.27 40.10 19.83 30.00 -10.17
109.600 ** -16.13 36.70 20.57 30.00 -9.43
160.500 ** -12.11 31.50 19.39 30.00 -10.61
186.100 ** -11.06 30.40 19.34 30.00 -10.66
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 20: LED LOAD (HLG-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 252 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7157
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.500 ** -17.95 39.40 21.45 30.00 -8.55


68.400 ** -21.97 41.50 19.53 30.00 -10.47
85.400 ** -20.37 40.60 20.23 30.00 -9.77
110.300 ** -16.03 36.40 20.37 30.00 -9.63
156.000 ** -12.39 31.50 19.11 30.00 -10.89
186.400 ** -11.05 30.50 19.45 30.00 -10.55
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 21: LED LOAD (HLG-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 253 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7154
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.300 ** -18.25 39.40 21.15 30.00 -8.85


68.200 ** -21.93 41.50 19.57 30.00 -10.43
85.400 ** -20.37 40.60 20.23 30.00 -9.77
112.100 ** -15.81 36.40 20.59 30.00 -9.41
156.400 ** -12.37 31.50 19.13 30.00 -10.87
186.400 ** -11.05 30.50 19.45 30.00 -10.55
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 21: LED LOAD (HLG-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 254 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7158
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.88 39.00 21.12 30.00 -8.88


65.530 ** -21.52 41.60 20.08 30.00 -9.92
85.400 ** -20.37 40.50 20.13 30.00 -9.87
113.500 ** -15.64 36.40 20.76 30.00 -9.24
153.500 ** -12.56 31.40 18.84 30.00 -11.16
186.400 ** -11.05 30.40 19.35 30.00 -10.65
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 22: LED LOAD (HLG-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 255 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7161
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.300 ** -18.25 39.40 21.15 30.00 -8.85


67.500 ** -21.82 41.50 19.68 30.00 -10.32
85.500 ** -20.35 40.45 20.10 30.00 -9.90
112.300 ** -15.79 36.50 20.71 30.00 -9.29
154.600 ** -12.48 31.50 19.02 30.00 -10.98
189.500 ** -10.97 30.50 19.53 30.00 -10.47
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 22: LED LOAD (HLG-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 256 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7261
Temperature: 79.9 OPERATOR: Roy
Humidity: 55 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

45.000 ** -15.73 37.20 21.47 30.00 -8.53


76.000 ** -21.81 42.50 20.69 30.00 -9.31
86.230 ** -20.24 43.50 23.26 30.00 -6.74
110.000 ** -16.06 39.20 23.14 30.00 -6.86
165.000 ** -11.90 35.68 23.78 30.00 -6.22
208.200 ** -10.62 32.10 21.48 30.00 -8.52
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 23: LED LOAD (HLG-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 257 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7258
Temperature: 79.9 OPERATOR: Roy
Humidity: 55 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

48.200 ** -16.81 38.20 21.39 30.00 -8.61


71.000 ** -22.15 44.00 21.85 30.00 -8.15
84.250 ** -20.58 42.50 21.92 30.00 -8.08
111.000 ** -15.94 37.50 21.56 30.00 -8.44
154.000 ** -12.52 32.54 20.02 30.00 -9.98
204.000 ** -10.71 31.20 20.49 30.00 -9.51
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 23: LED LOAD (HLG-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 258 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7149
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

54.800 ** -19.15 39.00 19.85 30.00 -10.15


71.200 ** -22.14 41.60 19.46 30.00 -10.54
85.900 ** -20.29 40.30 20.01 30.00 -9.99
109.900 ** -16.07 37.00 20.93 30.00 -9.07
155.200 ** -12.44 30.90 18.46 30.00 -11.54
195.800 ** -10.86 31.00 20.14 30.00 -9.86
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 24: LED LOAD (HLG-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 259 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7146
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

53.800 ** -18.79 39.50 20.71 30.00 -9.29


66.800 ** -21.72 42.60 20.88 30.00 -9.12
83.600 ** -20.68 40.50 19.82 30.00 -10.18
110.700 ** -15.97 36.80 20.83 30.00 -9.17
158.300 ** -12.24 30.90 18.66 30.00 -11.34
195.700 ** -10.86 30.40 19.54 30.00 -10.46
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 24: LED LOAD (HLG-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 260 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7262
Temperature: 79.9 OPERATOR: Roy
Humidity: 55 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

45.000 ** -15.73 38.40 22.67 30.00 -7.33


75.000 ** -21.92 42.50 20.58 30.00 -9.42
83.100 ** -20.78 43.50 22.72 30.00 -7.28
110.000 ** -16.06 36.50 20.44 30.00 -9.56
134.000 ** -13.72 34.50 20.78 30.00 -9.22
205.000 ** -10.69 31.53 20.84 30.00 -9.16
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 25: LED LOAD (HLG-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 261 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7265
Temperature: 79.9 OPERATOR: Roy
Humidity: 55 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

43.500 ** -15.06 35.12 20.06 30.00 -9.94


65.000 ** -21.44 39.54 18.10 30.00 -11.90
83.240 ** -20.75 42.50 21.75 30.00 -8.25
111.000 ** -15.94 33.10 17.16 30.00 -12.84
145.000 ** -13.05 34.00 20.95 30.00 -9.05
205.000 ** -10.69 31.20 20.51 30.00 -9.49
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 25: LED LOAD (HLG-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 262 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7165
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.300 ** -18.25 39.40 21.15 30.00 -8.85


67.500 ** -21.82 41.50 19.68 30.00 -10.32
85.600 ** -20.34 40.20 19.86 30.00 -10.14
110.300 ** -16.03 36.50 20.47 30.00 -9.53
164.500 ** -11.92 31.50 19.58 30.00 -10.42
189.500 ** -10.97 30.40 19.43 30.00 -10.57
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 26: LED LOAD (HLG-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 263 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7162
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.600 ** -18.35 39.60 21.25 30.00 -8.75


67.500 ** -21.82 41.50 19.68 30.00 -10.32
85.300 ** -20.39 40.30 19.91 30.00 -10.09
113.200 ** -15.68 36.50 20.82 30.00 -9.18
153.500 ** -12.56 31.50 18.94 30.00 -11.06
186.500 ** -11.05 30.40 19.35 30.00 -10.65
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 26: LED LOAD (HLG-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 264 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7206
Temperature: 11.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

50.300 ** -17.52 38.10 20.58 30.00 -9.42


65.200 ** -21.47 41.00 19.53 30.00 -10.47
85.900 ** -20.29 40.30 20.01 30.00 -9.99
110.000 ** -16.06 36.50 20.44 30.00 -9.56
156.800 ** -12.34 30.70 18.36 30.00 -11.64
196.800 ** -10.84 30.30 19.46 30.00 -10.54
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 27: LED LOAD (HLG-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 265 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7205
Temperature: 11.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.300 ** -18.25 39.40 21.15 30.00 -8.85


67.100 ** -21.76 41.60 19.84 30.00 -10.16
85.400 ** -20.37 40.30 19.93 30.00 -10.07
115.400 ** -15.42 36.20 20.78 30.00 -9.22
155.200 ** -12.44 30.60 18.16 30.00 -11.84
196.500 ** -10.85 30.20 19.35 30.00 -10.65
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 27: LED LOAD (HLG-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 266 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7166
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.88 39.40 21.52 30.00 -8.48


67.500 ** -21.82 41.50 19.68 30.00 -10.32
85.600 ** -20.34 40.50 20.16 30.00 -9.84
110.500 ** -16.00 36.50 20.50 30.00 -9.50
152.500 ** -12.62 31.45 18.83 30.00 -11.17
189.500 ** -10.97 30.40 19.43 30.00 -10.57
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 28: LED LOAD (HLG-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 267 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLG-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7169
Temperature: 17.6 OPERATOR: Wade
Humidity: 56 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.600 ** -18.35 39.40 21.05 30.00 -8.95


68.500 ** -21.98 41.50 19.52 30.00 -10.48
85.600 ** -20.34 40.50 20.16 30.00 -9.84
112.600 ** -15.74 36.50 20.76 30.00 -9.24
153.300 ** -12.57 31.50 18.93 30.00 -11.07
189.200 ** -10.96 30.50 19.54 30.00 -10.46
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 28: LED LOAD (HLG-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 268 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6775
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.40 21.55 30.00 -8.45


71.600 ** -22.18 40.80 18.62 30.00 -11.38
86.300 ** -19.95 40.30 20.35 30.00 -9.65
110.500 ** -16.00 36.20 20.20 30.00 -9.80
153.800 ** -12.63 30.60 17.97 30.00 -12.03
195.700 ** -11.02 30.40 19.38 30.00 -10.62
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 29: LED LOAD (HLN-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 269 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-12A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6772
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.20 21.35 30.00 -8.65


64.800 ** -21.48 45.20 23.72 30.00 -6.28
85.600 ** -20.10 40.70 20.60 30.00 -9.40
110.600 ** -15.99 36.50 20.51 30.00 -9.49
135.700 ** -13.56 34.60 21.04 30.00 -8.96
195.800 ** -11.02 30.70 19.68 30.00 -10.32
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 29: LED LOAD (HLN-80H-12A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 270 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6776
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.50 21.65 30.00 -8.35


72.600 ** -22.11 40.90 18.79 30.00 -11.21
86.100 ** -20.00 40.50 20.50 30.00 -9.50
114.300 ** -15.59 36.50 20.91 30.00 -9.09
158.300 ** -12.34 30.60 18.26 30.00 -11.74
198.200 ** -11.01 30.70 19.69 30.00 -10.31
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 30: LED LOAD (HLN-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 271 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-15A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6779
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

64.200 ** -21.31 47.60 26.29 30.00 -3.71


74.200 ** -21.99 42.10 20.11 30.00 -9.89
85.900 ** -20.04 40.60 20.56 30.00 -9.44
110.600 ** -15.99 36.50 20.51 30.00 -9.49
135.200 ** -13.59 36.30 22.71 30.00 -7.29
194.800 ** -11.02 30.70 19.68 30.00 -10.32
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 30: LED LOAD (HLN-80H-15A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 272 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6783
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.20 21.35 30.00 -8.65


72.500 ** -22.12 40.30 18.18 30.00 -11.82
85.600 ** -20.10 40.30 20.20 30.00 -9.80
111.300 ** -15.92 36.50 20.58 30.00 -9.42
152.300 ** -12.73 30.40 17.67 30.00 -12.33
195.300 ** -11.02 30.20 19.18 30.00 -10.82
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 31: LED LOAD (HLN-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 273 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-20A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6780
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.200 ** -17.82 39.50 21.68 30.00 -8.32


66.000 ** -21.69 45.30 23.61 30.00 -6.39
85.400 ** -20.15 40.50 20.35 30.00 -9.65
109.900 ** -16.07 36.50 20.43 30.00 -9.57
138.200 ** -13.41 34.20 20.79 30.00 -9.21
195.600 ** -11.02 30.50 19.48 30.00 -10.52
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 31: LED LOAD (HLN-80H-20A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 274 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6784
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.50 21.65 30.00 -8.35


72.500 ** -22.12 40.50 18.38 30.00 -11.62
85.600 ** -20.10 40.30 20.20 30.00 -9.80
110.300 ** -16.03 36.50 20.47 30.00 -9.53
153.600 ** -12.64 30.50 17.86 30.00 -12.14
195.600 ** -11.02 30.50 19.48 30.00 -10.52
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 32: LED LOAD (HLN-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 275 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-24A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6787
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.40 21.55 30.00 -8.45


66.500 ** -21.77 45.30 23.53 30.00 -6.47
85.600 ** -20.10 40.30 20.20 30.00 -9.80
110.600 ** -15.99 36.50 20.51 30.00 -9.49
135.200 ** -13.59 35.20 21.61 30.00 -8.39
194.200 ** -11.02 30.50 19.48 30.00 -10.52
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 32: LED LOAD (HLN-80H-24A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 276 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6791
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.400 ** -18.23 39.50 21.27 30.00 -8.73


72.500 ** -22.12 40.60 18.48 30.00 -11.52
85.700 ** -20.08 40.60 20.52 30.00 -9.48
110.600 ** -15.99 36.20 20.21 30.00 -9.79
153.600 ** -12.64 30.80 18.16 30.00 -11.84
195.600 ** -11.02 30.20 19.18 30.00 -10.82
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 33: LED LOAD (HLN-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 277 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-30A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6788
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.50 21.65 30.00 -8.35


66.900 ** -21.83 48.40 26.57 30.00 -3.43
85.700 ** -20.08 40.50 20.42 30.00 -9.58
110.600 ** -15.99 36.50 20.51 30.00 -9.49
135.200 ** -13.59 37.20 23.61 30.00 -6.39
195.300 ** -11.02 30.50 19.48 30.00 -10.52
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 33: LED LOAD (HLN-80H-30A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 278 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6792
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.600 ** -18.30 39.40 21.10 30.00 -8.90


72.500 ** -22.12 40.60 18.48 30.00 -11.52
85.600 ** -20.10 40.30 20.20 30.00 -9.80
112.500 ** -15.80 36.40 20.60 30.00 -9.40
153.600 ** -12.64 30.40 17.76 30.00 -12.24
195.800 ** -11.02 30.60 19.58 30.00 -10.42
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 34: LED LOAD (HLN-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 279 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-36A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6795
Temperature: 19.4 OPERATOR: Wade
Humidity: 54 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.300 ** -17.85 39.50 21.65 30.00 -8.35


65.200 ** -21.57 45.70 24.13 30.00 -5.87
85.600 ** -20.10 40.50 20.40 30.00 -9.60
115.400 ** -15.47 36.40 20.93 30.00 -9.07
139.000 ** -13.37 34.50 21.13 30.00 -8.87
195.600 ** -11.02 30.50 19.48 30.00 -10.52
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 34: LED LOAD (HLN-80H-36A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 280 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6799
Temperature: 23.8 OPERATOR: Wade
Humidity: 50 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

50.300 ** -17.51 39.00 21.49 30.00 -8.51


64.400 ** -21.37 41.10 19.73 30.00 -10.27
82.600 ** -20.72 40.30 19.58 30.00 -10.42
110.600 ** -15.99 36.40 20.41 30.00 -9.59
137.000 ** -13.48 34.20 20.72 30.00 -9.28
191.300 ** -11.03 30.70 19.67 30.00 -10.33
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 35: LED LOAD (HLN-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 281 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-42A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6796
Temperature: 23.8 OPERATOR: Wade
Humidity: 50 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.500 ** -18.26 39.10 20.84 30.00 -9.16


65.180 ** -21.57 45.30 23.73 30.00 -6.27
85.600 ** -20.10 40.30 20.20 30.00 -9.80
110.300 ** -16.03 36.80 20.77 30.00 -9.23
136.000 ** -13.54 36.30 22.76 30.00 -7.24
196.400 ** -11.01 30.80 19.79 30.00 -10.21
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 35: LED LOAD (HLN-80H-42A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 282 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6800
Temperature: 23.8 OPERATOR: Wade
Humidity: 50 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.300 ** -18.20 39.10 20.90 30.00 -9.10


65.500 ** -21.61 41.00 19.39 30.00 -10.61
85.700 ** -20.08 40.50 20.42 30.00 -9.58
110.600 ** -15.99 36.50 20.51 30.00 -9.49
138.500 ** -13.40 34.30 20.90 30.00 -9.10
195.400 ** -11.01 30.50 19.49 30.00 -10.51
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 36: LED LOAD (HLN-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 283 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-48A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6803
Temperature: 23.8 OPERATOR: Wade
Humidity: 50 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.300 ** -18.20 39.50 21.30 30.00 -8.70


64.300 ** -21.34 46.00 24.66 30.00 -5.34
85.500 ** -20.12 40.70 20.58 30.00 -9.42
122.800 ** -14.66 39.00 24.34 30.00 -5.66
153.600 ** -12.64 30.70 18.06 30.00 -11.94
193.300 ** -11.02 32.40 21.38 30.00 -8.62
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 36: LED LOAD (HLN-80H-48A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 284 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6807
Temperature: 23.8 OPERATOR: Wade
Humidity: 50 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

52.300 ** -18.20 39.30 21.10 30.00 -8.90


66.200 ** -21.73 41.80 20.07 30.00 -9.93
86.300 ** -19.95 40.50 20.55 30.00 -9.45
109.900 ** -16.07 36.60 20.53 30.00 -9.47
126.300 ** -14.28 35.60 21.32 30.00 -8.68
192.100 ** -11.03 31.30 20.27 30.00 -9.73
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 37: LED LOAD (HLN-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 285 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLN-80H-54A Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/6804
Temperature: 23.8 OPERATOR: Wade
Humidity: 50 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

51.200 ** -17.82 39.40 21.58 30.00 -8.42


66.900 ** -21.83 45.60 23.77 30.00 -6.23
85.500 ** -20.12 40.60 20.48 30.00 -9.52
109.900 ** -16.07 37.20 21.13 30.00 -8.87
125.300 ** -14.39 38.30 23.91 30.00 -6.09
191.300 ** -11.03 31.60 20.57 30.00 -9.43
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 37: LED LOAD (HLN-80H-54A) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 286 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Horizontal
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLP-80H-48 Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7254
Temperature: 79.9 OPERATOR: Roy
Humidity: 55 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

47.000 ** -16.40 37.50 21.10 30.00 -8.90


76.000 ** -21.81 43.50 21.69 30.00 -8.31
86.000 ** -20.28 42.50 22.22 30.00 -7.78
110.000 ** -16.06 37.10 21.04 30.00 -8.96
137.000 ** -13.51 34.56 21.05 30.00 -8.95
186.000 ** -11.06 33.56 22.50 30.00 -7.50
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 38: LED LOAD (HLP-80H-48) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 287 of 385

Radiated Emission Measurement Data


EUT: Switching Power Supply POLARITY: Vertical
CLIENT: MEAN WELL DISTANCE: 10 m
MODEL: HLP-80H-48 Serial No.:
RATING: 110V/60Hz FILE/DATA#: MEAN WELL.emi/7257
Temperature: 79.9 OPERATOR: Roy
Humidity: 55 % TEST SITE: OATS 1

Frequency Factor Meter Reading Emission Level Limits Margin

(MHz) (dB) (dBV) (dBV/m) (dBV/m) (dB)

45.000 ** -15.73 38.25 22.52 30.00 -7.48


78.250 ** -21.55 43.50 21.95 30.00 -8.05
86.240 ** -20.24 42.50 22.26 30.00 -7.74
118.400 ** -15.06 31.50 16.44 30.00 -13.56
145.000 ** -13.05 34.54 21.49 30.00 -8.51
204.000 ** -10.71 32.50 21.79 30.00 -8.21
Remark:
1. * Mark means readings are Peak Values.
2. ** Mark means readings are Quasi-Peak values.
3. Factor = Antenna Factor + Cable Loss Pre-amplifier.
LIMIT: EN55015_B.LMT

Test Mode: Mode 38: LED LOAD (HLP-80H-48) (110V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 288 of 385

5 Harmonic Current Emission Measurement (EN 61000-3-2)

5.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

EMC EMISSION TESTER EMC PARTMER HARMONICS-1000 41 2011/04/15


Note: The above equipments are within the valid calibration period.

5.2 Block Diagram of Test Configuration

EMC EMISSION EUT


TESTER

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 289 of 385

5.3 Test Limit


Class A Equipment
Harmonic order (n) Maximum permissible harmonic current (A)
Odd harmonics
3 2.30
5 1.14
7 0.77
9 0.40
11 0.33
13 0.21
15 n 39 0.15 15 / n
Even harmonics
2 1.08
4 0.43
6 0.30
8 n 40 0.23 8 / n

Class B Equipment
For Class B equipment, the harmonics of the input current shall not exceed the values given in
Class A equipment multiplied by a factor of 1.5.

Class C Equipment
Harmonic order Maximum permissible harmonic current
expressed as a percentage of the input
current at the fundamental frequency
(n) %
2 2
3 30.*
5 10
7 7
9 5
11 n 39 3
(odd harmonics only)
*is the circuit power factor

Class D Equipment
Harmonic order Maximum permissible Maximum permissible
harmonic current harmonic current
Per watt
(n) (mA/W) (A)
3 3.4 2.30
5 1.9 1.14
7 1.0 0.77
9 0.5 0.40
11 0.35 0.33
13 n 39 3.85/n See Class A equipment
(odd harmonics only)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 290 of 385

5.4 Configuration of Measurement


5.4.1 The EUT with power analyzer is in series and supplied from a power source with the same
nominal voltage and frequency as the rated supply voltage.
5.4.2 Set the output of the power analyzer to the rated voltage and frequency of EUT (230V,
50Hz).
5.4.3 The EUT classified by the C Detect function. The measurement was automatic performed
by test software. The test result was collected and analyzed by the computer.
5.4.4 Active input power25W
For lighting equipment having an active input power greater than 25W, the harmonic
currents shall not exceed the relative limits given in Class C Equipment.
5.4.5 Active input power25W
Discharge lighting equipment having an active input power smaller than or equal to 25W
shall comply with one of the following two sets of requirements:
- the harmonic currents shall not exceed the power-related limits of Class D, column 2,or:
5.4.6 - the third harmonic current, expressed as a percentage of the fundamental current, shall not
exceed 86% and the fifth shall not exceed 61%; moreover, the waveform of the input current
shall be such that it begins to flow before or at 60, has its last peak (if there are several
peaks per half period) before or at 65 and does not stop flowing before 90, where the
zero crossing of the fundamental supply voltage is assumed to be at 0.

5.5 Test Result


PASS.
The measured result is shown as following pages.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 291 of 385

100% LED LOAD (HLG-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 292 of 385

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 293 of 385

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 294 of 385

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 295 of 385

60% LED LOAD (HLG-80H-48A) (230V)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 296 of 385

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 297 of 385

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 298 of 385

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 299 of 385

6 Voltage Fluctuations and Flicker Measurement (EN 61000-3-3)

6.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

EMC EMISSION TESTER EMC PARTMER HARMONICS-1000 41 2011/04/15


Note: The above equipments are within the valid calibration period.

6.2 Block Diagram of Test Configuration

EMC EMISSION EUT


TESTER

6.3 Test Limit


The following limits apply:
- the value of Pst shall not be greater than 1.0;
- the value of Plt shall not be greater than 0.65;
- the relative steady-state voltage change, dc shall not exceed 3.3%;
- the maximum relative voltage change, dmax shall not exceed 4%;
- the value of d(t) during a voltage change shall not exceed 3.3% for more than 500 ms.

6.4 Configuration of Measurement


6.4.1 The EUT with power analyzer is in series and supplied from a power source with the same
nominal voltage and frequency as the rated supply voltage.
6.4.2 Set the output of the power analyzer to the rated voltage and frequency of EUT (230V,
50Hz).
6.4.3 Select the test time of observation period for short-term (Tp = 10 min) and long-term (Tp = 2
hrs). The test result was collected and analyzed by the computer.

6.5 Test Result


PASS.
The measured result is shown as following pages.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 300 of 385

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 301 of 385

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 302 of 385

7 Performance Criterion of Immunity Test

7.1 EN 61547
Criterion Description
A During the test no change of the luminous intensity shall be observed and the
regulating control, if any, shall operate during the test as intended.

B During the test the luminous intensity may change to any value. After the test the
luminous intensity shall be restored to its initial value within 1 min.
Regulating controls need not function during the test, but after the test the mode of
the control shall be the same as before the test provided that during the test no mode
changing commands were given.

C During and after the test any change of the luminous intensity is allowed and the
lamp(s) may be extinguished. After the test, within 30 min, all functions shall return
to normal if necessary by temporary interruption of the mains supply and / or
operation the regulating control.
Additional requirement for lighting equipment incorporation a starting device:
After the test the lighting equipment is switched off. After half an hour it is switched
on again. The lighting equipment shall start and operate as intended.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 303 of 385

8 Electrostatic Discharge Immunity Test (EN 61000-4-2)

8.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

ESD Simulator EMC PARTNER ESD3000 276 2011/01/12


Note: The above equipments are within the valid calibration period.

8.2 Block Diagram of Test Configuration

10 cm
ESD Generator
Vertical
Coupling Insulation
Plane EUT
Ground
Connection (HCP)

470k 470k
80 cm Resister Resister

Metal Ground Plane

8.3 Test Levels


Level Contact discharge (kV) Air discharge (kV)
1 2 2
2 4 4
3 6 8
4 8 15
X Special Special

8.4 Test Requirement


8.4.1 EN 61000-4-2 (EN 61547) require:
Air discharge: 8 kV
Contact discharge: 4 kV
Performance criterion: B

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 304 of 385

8.5 Configuration of Measurement


8.5.1 Static electricity discharges shall be applied only to those points and surfaces of the EUT
which are expected to be touched during usual operation, including user access, as
specified in the user manual, for example for ribbon and paper roll changes.
8.5.2 The discharges shall be applied in two ways:
a) Contact discharges to the conductive surfaces and to coupling planes:
The EUT shall be exposed to at least 200 discharges, 100 each at negative and positive
polarity, at a minimum of four test points (a minimum of 50 discharges at each point).
One of the test points shall be subjected to at least 50 indirect discharges (contact) to
the center of the front edge of the horizontal coupling plane (HCP), the remaining three
test points shall each receive at least 50 direct contact discharges. If no direct contact
test points are available, then at least 200 indirect discharges shall be applied in the
indirect mode (see EN 61000-4-2 for use of the Vertical Conducting Plane (VCP)). Tests
shall be performed at a maximum repetition rate of one discharge per second.
b) Air discharge at slots and apertures, and insulating surfaces:
On those parts of the EUT where it is not possible to perform contact discharge testing,
the equipment should be investigated to identify user accessible points where
breakdown may occur; examples are openings at edges of keys, or in the covers of
keyboards and telephone handsets. Such points are tested using the air discharge
method. See also EN 61000-4-2 regarding painted surfaces. This investigation should
be restricted to those areas normally handled by the user. A minimum of 10 single air
discharges shall be applied to the selected test point for each such area.
8.5.3 The ESD generator (gun) was held perpendicular to the surface to which the discharge was
applied. The application of electrostatic discharges to the contacts of open connectors is not
required.

8.6 Test Result


Temperature: 22.5 Humidity: 51 % Atm pres: 101 Kpa Test Engineer: Bill

PASS.

8.6.1 The performance criterion after tested EN 61000-4-2 (EN 61547):


Air discharge 2 kV, 4 kV, 8 kV: A B C
Contact discharge 2 kV, 4 kV: A B C
Indirect discharge (HCP) 2 kV, 4 kV: A B C
Indirect discharge (VCP Front, Left, Back, Right) 2 kV, 4 kV:
A B C

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 305 of 385

9 Radio-Frequency, Electromagnetic Field Immunity Test (EN 61000-4-3)

9.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

Signal Generator R&S SM300 101279 2012/10/18

RF Power Amplifier Frankonia FLG-200B 1038 2011/02/21

RF Power Amplifier Frankonia FLG-50C 1013 2011/02/21

Bilog Antenna Frankonia BTA-M 06012M 2011/02/21


Note: The above equipments are within the valid calibration period.

9.2 Block Diagram of Test Configuration

Chamber
3m

RF Cable
EUT
1m
80 cm

Signal Generator PC Controller

RF Power Amplifier

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 306 of 385

9.3 Test Levels


Level Test field strength (V/m)
1 1
2 3
3 10
4 30
X Special

9.4 Test Requirement


9.4.1 EN 61000-4-3 (EN 61547) require:
The frequency steps: 1%, Log sweep, Dwell time: 3.0 sec.
Frequency range: 80 to 1000 MHz, Field strength: 3 V/m, 80%AM (1kHz),
Performance criterion: A

9.5 Configuration of Measurement


9.5.1 Before testing, the intensity of the established field strength was checked by placing the
field sensor at a calibration grid point, and with the field generating antenna and cables in
the same positions as used for the calibration, the forward and reverse power were
measured. The forward power needed to give the calibrated field was evaluated.
9.5.2 The EUT was placed on a non-metallic table 0.8m above the reference ground plane (RGP)
and was operated according to its specified operating mode.
9.5.3 Ferrite tiles/ absorbers were placed on the RGP between the EUT and the antenna to
reduce the reflections from the RGP.
9.5.4 The distance between antenna and EUT is 3 meter.
9.5.5 During the test EUT performance has been monitoring by CCD camera.

9.6 Test Result


Temperature: 22.6 Humidity: 54 % Atm pres: 101 Kpa Test Engineer: Bill

PASS.

9.6.1 The performance criterion after tested EN 61000-4-3 (EN 61547):


Frequency range: 80 to 1000 MHz, Field strength: 3 V/m, 80% AM (1kHz),
Performance criterion: A B C

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 307 of 385

10 Electrical Fast Transient/Burst Immunity Test (EN 61000-4-4)

10.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

EMC Pro System KeyTek EMC Pro 0003231 2011/04/07


Note: The above equipments are within the valid calibration period.

10.2 Block Diagram of Test Configuration


For Power Ports.

EUT

Burst Generator Ground Plane


10cm

Insulation support

Grounding cable

Bounding
Metal Ground Plane

10.3 Test Levels


Open circuit output test voltage and repetition rate of the impulses
On I/O (input/output) signal, data
On power port, PE
and control ports
Level
Voltage peak Repetition rate Voltage peak Repetition rate
kV kHz kV kHz
1 0,5 5 or 100 0,25 5 or 100
2 1 5 or 100 0,5 5 or 100
3 2 5 or 100 1 5 or 100
4 4 5 or 100 2 5 or 100
a
X Special Special Special Special
NOTE 1: Use of 5 kHz repetition rates is traditional; however, 100 kHz is closer to reality.
Product committees should determine which frequencies are relevant for specific products or
product types.
NOTE 2: With some products, there may be no clear distinction between power ports and I/O
ports, in which case it is up to product committees to make this determination for test
purposes.
a
X is an open level. The level has to be specified in the dedicated equipment specification.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 308 of 385

10.4 Test Requirement


10.4.1 EN 61000-4-4 (EN 61547) require:
5 kHz Repetition frequency
1.0 kV input AC power ports.
1.0 kV output AC power ports.
0.5 kV input DC power ports.
0.5 kV output DC power ports.
0.5 kV Signal and Control ports.
Performance criterion: B

10.5 Configuration of Measurement


10.5.1 The EUT and the auxiliary equipment were placed on a wooden table of 0.8 meters height.
The size of ground plane is greater than 1m1m and project beyond the EUT by at least
0.1m on all sides. The ground plane is connected to the protective earth.
10.5.2 The EUT was connected to the power mains through a coupling device that directly couples
the EFT interference signal. Each of the Line, Loop and Protective Earth (PE) conductors
was impressed with burst noise for 1 minute. Both the voltage polarities were applied for
each test level. The length of the signal and power lines between the coupling device and
the EUT shall be 0,5m 0,05m.

10.6 Test Result


Temperature: 23.2 Humidity: 53 % Atm pres: 101 Kpa Test Engineer: Bill

PASS.

10.6.1 The performance criterion after tested EN 61000-4-4 (EN 61547):


1.0 kV input AC power ports: Line + Neutral + PE
Performance criterion: A B C

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 309 of 385

11 Surge Immunity Test (EN 61000-4-5)

11.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

EMC Pro Systems KeyTek EMC Pro 0003234 2011/03/16


Note: The above equipments are within the valid calibration period.

11.2 Block Diagram of Test Configuration

Surge
EUT Generator

Controller Computer

11.3 Test Levels


Level Open-circuit test voltage 10% (kV)
1 0.5
2 1.0
3 2.0
4 4.0
X Special
Note: X can be any level, above, below or in between the other levels.
This level can be specified in the product standard.

11.4 Test Requirement


11.4.1 EN 61000-4-5 (EN 61547) require:
Input AC power ports (25W): Line to line: 0.5kV (peak), 1.2/50 (8/20) Tr/Th us
Line to earth (ground): 1.0kV (peak), 1.2/50 (8/20) Tr/Th us
Input AC power ports (25W): Line to line: 1.0kV (peak), 1.2/50 (8/20) Tr/Th us
Line to earth (ground): 2.0kV (peak), 1.2/50 (8/20) Tr/Th us
Performance criterion: C

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 310 of 385

11.5 Configuration of Measurement


11.5.1 The EUT and support units were located on a wooden table 0.8 m away from ground floor.
11.5.2 The EUT was connected to the power mains through a coupling device that directly couples
the Surge interference signal. The surge noise was applied synchronized to the voltage
phase at the zero crossing and the peak value of the AC voltage wave (positive and
negative).
11.5.3 The surges were applied line to line and line(s) to earth. When testing line to earth the test
voltage was applied successively between each of the lines and earth. Steps up to the test
level specified increased the test voltage. All lower levels including the selected test level
were tested. The polarity of each surge level included positive and negative test pulses.

11.6 Test Result


Temperature: 22.6 Humidity: 54 % Atm pres: 101 Kpa Test Engineer: Bill

PASS.

11.6.1 The performance criterion after tested EN 61000-4-5 (EN 61547):


0.5 (+5 ~ -10%) kV (peak) input AC power port (25W): Line to line
Performance criterion: A B C
1.0 (+5 ~ -10%) kV (peak) input AC power port (25W): Line to line
Performance criterion: A B C
2.0 (+5 ~ -10%) kV (peak) input AC power port (25W): Line to line
Performance criterion: A B C
0.5 (+5 ~ -10%) kV (peak) input AC power port (25W): Line to earth (ground)
Performance criterion: A B C
1.0 (+5 ~ -10%) kV (peak) input AC power port (25W): Line to earth (ground)
Performance criterion: A B C
2.0 (+5 ~ -10%) kV (peak) input AC power port (25W): Line to earth (ground)
Performance criterion: A B C
4.0 (+5 ~ -10%) kV (peak) input AC power port (25W): Line to earth (ground)
Performance criterion: A B C

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 311 of 385

12 Radio-Frequency, Conducted Disturbances Immunity Test (EN 61000-4-6)

12.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

Signal Generator R&S SMY02 829846/013 2012/08/25

Power Amplifier Frankonia CIT-10 162D1278 2011/02/11

Attenuator SCHAFFNER ATN6075 22300 2011/02/11

C.D.N FCC FCC-801-M3-25A 2045 2011/02/11

C.D.N SCHAFFNER M216 16394 2011/02/11


Note: The above equipments are within the valid calibration period.

12.2 Block Diagram of Test Configuration


For Power Ports.

50 terminator
6dB Attenuator
30 cm
C.D.N. EUT AE C.D.N.
Main Power
10 cm
Metal Ground Plane

Power Amplifier Signal Generator PC Controller

12.3 Test Levels


Level Voltage Level (V)
1 1
2 3
3 10
X Special

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 312 of 385

12.4 Test Requirement


12.4.1 EN 61000-4-6 (EN 61547) require:
The frequency steps: 1%, Log sweep, Dwell time: 3.0 sec.
Frequency Range is from 0.15 to 80MHz.
Field strength: 3 V, 80% AM (1kHz)
Input AC power ports.
Output AC power ports.
Input DC power ports.
Output DC power ports.
Signal and Control ports.
Performance criterion: A

12.5 Configuration of Measurement


12.5.1 The EUT was placed on a table of is 0.1 m height. In Semi-Anechoic chamber A Ground
reference plane was placed on the table and a 0.1 meter insulating support was inserted
between the EUT and Ground reference plane.
12.5.2 The EUT was connected to the power mains through a Coupling and Decoupling Networks
(CDN).
12.5.3 The test was performed with the test generator connected to each of the coupling and
decoupling devices in turn while the other non-excited RF input ports of the coupling devices
were terminated by a 50 terminator.
12.5.4 The frequency range was swept from 150kHz to 80MHz.using the signal levels established
during the setting process, and without the disturbance signal 80% amplitude modulated
with a 1 kHz sine wave, pausing to adjust the RF signal level or to switch coupling devices
as necessary. The rate of sweep was less than 1.510-3 decades/s. And the step size of the
frequency sweep was also less than 1% of the start and thereafter 1% of the preceding
frequency value. The dwell time at each frequency was more than the time necessary for
the EUT to be excited, and able to respond.
12.5.5 The EUT was fully excised during the testing and all the selected excise modes were fully
interrogated for susceptibility.

12.6 Test Result


Temperature: 23.1 Humidity: 52 % Atm pres: 101 Kpa Test Engineer: Bill

PASS.
12.6.1 The performance criterion after tested EN 61000-4-6 (EN 61547):
Frequency range: 0.15 to 80 MHz, Field strength: 3 V, 80% AM (1kHz),
Input AC power port.
Performance criterion: A B C

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 313 of 385

13 Power Frequency Magnetic Field Immunity Test (EN 61000-4-8)

13.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

Magnetic field generator PMM PMM1008 0000J00301 2012/09/09


Note: The above equipments are within the valid calibration period.

13.2 Block Diagram of Test Configuration

Induction coil
1/2 Dimension of EUT
EUT

Ground Plane Magnetic field generator


(Copper)
10cm
Insulating
Safety earth Support

Non-Conducted Table

13.3 Test Levels


Level Magnetic field strength (A/m)
1 1
2 3
3 10
4 30
5 100
X Special

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 314 of 385

13.4 Test Requirement


13.4.1 EN 61000-4-8 (EN 61547) require:
Power Frequency is 50 or 60Hz.
Magnetic field strength: 3A/m
Performance criterion: A

13.5 Configuration of Measurement


13.5.1 The equipment is configured and connected to satisfy its functional requirements. It shall be
placed on the GRP (1m x 1m) with the interposition of a 0.1m thickness insulating support.
13.5.2 All cables shall be exposed to the magnetic field for 1m of their length.
13.5.3 Different induction coils may be selected for testing in the different orthogonal directions.
13.5.4 Induction coils used in the vertical position (horizontal polarization of the field) can be
bonded directly to the ground plane.

13.6 Test Result


Temperature: 23.4 Humidity: 52 % Atm pres: 101 Kpa Test Engineer: Bill

PASS.

13.6.1 The performance criterion after tested EN 61000-4-8 (EN 61547):


Power Frequency is 50Hz, Magnetic field strength: 3A/m
Performance criterion: A B C

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 315 of 385

14 Voltage Dips, Short Interruptions Immunity Test (EN 61000-4-11)

14.1 Instrument
Instrument Manufacturer Model Serial No. Next Cal. Date

EMC Pro System KeyTek EMC Pro 0003231 2011/04/07


Note: The above equipments are within the valid calibration period.

14.2 Block Diagram of Test Configuration

EUT

EMC Pro System Ground Plane


10cm

Insulation support AC Line

Grounding cable

Bounding
Metal Ground Plane

14.3 Test Levels


Preferred test level and durations for voltage dips
Class a Test level and durations for short interruptions (ts) (50 Hz/60 Hz)
Class 1 Case-by-case according to the equipment requirements
0 % during 0 % during
Class 2 70 % during 25/30c cycles
1/2 cycle 1 cycle
0 % during 0 % during 40 % during 70 % during 80 % during
Class 3
1/2 cycle 1 cycle 10/12 cycles 25/30 cycles 250/300c cycles
c c

Class Xb X X X X X
a
Classes as per EN 61000-2-4; see Annex B.
b
To be defined by product committee. For equipment connected directly or indirectly to the public
network, the levels must not be less severe than Class 2.
c
25/30 cycles means 25 cycles for 50 Hz test and 30 cycles for 60 Hz test.
Preferred test level and durations for short interruptions
Class a Test level and durations for short interruptions (ts) (50 Hz/60 Hz)
Class 1 Case-by-case according to the equipment requirements
Class 2 0 % during 250/300c cycles
Class 3 0 % during 250/300c cycles
Class Xb X
a
Classes as per EN 61000-2-4; see Annex B.
b
To be defined by product committee. For equipment connected directly or indirectly to the public
network, the levels must not be less severe than Class 2.
c
250/300 cycles means 250 cycles for 50 Hz test and 300 cycles for 60 Hz test.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 316 of 385

14.4 Test Requirement


14.4.1 EN 61000-4-11 (EN 61547) require:
30% reduction (Voltage Dips), 10 period, Performance criterion: C
100% reduction (Voltage Interruptions), 0.5 period, Performance criterion: B

14.5 Configuration of Measurement


14.5.1 The power cord was used as supplied by the manufacturer. The EUT was connected to the
line output of the Voltage Dips and Interruption Generator.
14.5.2 The EUT was tested for (I) 30% voltage dip of supplied voltage with duration of 10 period, (II)
100% voltage Interruption of supplied voltage and duration 0.5 period. The dip tests was
carried out for a sequence of three voltage dips with intervals of 10 seconds.
14.5.3 Voltage reduction was controlled at 0, 45, 90, 135, 180, 225, 270 and 315 of the
voltage phase angle. The performance of the EUT was checked after the voltage dip or
interruption.

14.6 Test Result


Temperature: 23.2 Humidity: 53 % Atm pres: 101 Kpa Test Engineer: Bill

PASS.

14.6.1 The performance criterion after tested EN 61000-4-11 (EN 61547):


30% reduction (Voltage Dips), 10 period
Performance criterion: A B C
100% reduction (Voltage Interruptions), 0.5 period
Performance criterion: A B C

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 317 of 385

15 Photographs of Test

15.1 Main Terminal Disturbance Voltage Measurement

Front View

Rear View

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 318 of 385

15.2 Radiated Disturbance (9 kHz to 30 MHz) Measurement

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 319 of 385

15.3 Radiated Disturbance (30 MHz to 300 MHz) Measurement

Front View

Rear View

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 320 of 385

15.4 Harmonic Current & Voltage Fluctuations and Flicker Measurement

15.5 Electrostatic Discharge Immunity Test (EN 61000-4-2)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 321 of 385

15.6 Radio-Frequency, Electromagnetic Field Immunity Test (EN 61000-4-3)

Front View

Rear View

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 322 of 385

15.7 Electrical Fast Transient/Burst Immunity Test (EN 61000-4-4)

15.8 Surge Immunity Test (EN 61000-4-5)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 323 of 385

15.9 Radio-Frequency, Conducted Disturbances Immunity Test (EN 61000-4-6)

15.10 Power Frequency Magnetic Field Immunity Test (EN 61000-4-8)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 324 of 385

15.11 Voltage Dips, Short Interruptions Immunity Test (EN 61000-4-11)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 325 of 385

15.12 Electrostatic Discharge Test Point

View of Discharge Point-1 (Green: Air discharge; Red: Contact discharge)

View of Discharge Point-2 (Green: Air discharge; Red: Contact discharge)

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 326 of 385

16 Photographs of EUT

16.1 Model No.: HLG-80H-12A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 327 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 328 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 329 of 385

16.2 Model No.: HLG-80H-15A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 330 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 331 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 332 of 385

16.3 Model No.: HLG-80H-20A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 333 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 334 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 335 of 385

16.4 Model No.: HLG-80H-24A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 336 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 337 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 338 of 385

16.5 Model No.: HLG-80H-30A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 339 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 340 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 341 of 385

16.6 Model No.: HLG-80H-36A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 342 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 343 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 344 of 385

16.7 Model No.: HLG-80H-42A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 345 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 346 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 347 of 385

16.8 Model No.: HLG-80H-48A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 348 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 349 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 350 of 385

16.9 Model No.: HLG-80H-54A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 351 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 352 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 353 of 385

16.10 Model No.: HLN-80H-12A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 354 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 355 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 356 of 385

16.11 Model No.: HLN-80H-15A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 357 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 358 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 359 of 385

16.12 Model No.: HLN-80H-20A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 360 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 361 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 362 of 385

16.13 Model No.: HLN-80H-24A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 363 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 364 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 365 of 385

16.14 Model No.: HLN-80H-30A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 366 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 367 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 368 of 385

16.15 Model No.: HLN-80H-36A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 369 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 370 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 371 of 385

16.16 Model No.: HLN-80H-42A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 372 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 373 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 374 of 385

16.17 Model No.: HLN-80H-48A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 375 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 376 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 377 of 385

16.18 Model No.: HLN-80H-54A

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 378 of 385

Inner View of EUT

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 379 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 380 of 385

16.19 Model No.: HLP-80H-48

Front View of EUT

Rear View of EUT

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 381 of 385

Spec.

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 382 of 385

Component View of Main Board

Solder View of Main Board

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 383 of 385

17 Photographs of PCB

17.1 For HLG-80H-yz Series and HLN-80H-yz Series

Component View of PCB-1

Solder View of PCB-1

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 384 of 385

Component View of PCB-2

Solder View of PCB-2

Interocean EMC Technology Corp. CE Test Report


Report No.: 10A112301EL Page 385 of 385

17.2 For HLP-80H-yz Series

Component View of PCB

Solder View of PCB

Interocean EMC Technology Corp. CE Test Report