IR # TUV/KUB/01501/2013/023.
TV Inspector: Razu.Selvakumar
TV Coordinator: N.A
Approval #
Type of Visit: Initial Insp. In-Process Insp. Final Insp. Order Status
Client/Project Information
Equipment/Material Description
Purchase Order No.: 4500057417/418 Tag / (Unit Model): Coil No. 69, 70, 71 & 72 Radiant Coil (Hydro
15Th December 2013 Test).
Description: Witness Inspection for Weld joint Fit-up, Mechanical Test and Hydro test.
Progress
SUMMARY
Date of Last Visit: 14th December 2013
Date(s) of this Visit 15th December 2013 1 MAN-DAY
Next Scheduled Visit: 16th December 2013.
Any holder of this inspection report is advised that information contained hereon reflects the companys findings at the date and time of the inspection only and within the limits of
clients instructions and specifications, if any. The companys sole responsibility is to its client and this document does not exonerate parties to a transaction from exercising all their
rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders
Hydro Static Test, Liquid Penetrate Test, Macro Test, Visual Dimensional Test and welding Fit-up Inspection.
may be prosecuted to the fullest extent of the law
NATIONAL INSPECTION AND TECHNICAL TESTING CO. LTD. (FAHSS / TV NORD SAUDI ARABIA) P.O BOX 10771 JUBAIL 31961
JUBAIL: (03) 340 7607 / 7608 / 7609 FAX: (03) 340 7605 - JEDDAH: (02) 652 0212 / 614 3438 FAX: (02) 652 0822
YANBU: TEL / FAX (04) 325 1475 EMAIL: info@fahsstuv.com
Page 1 of 5
INSPECTION ACTIVITIES
1. Inspection Activities Identification: (Place an x mark in each of the boxes below that corresponds with an Inspection
activity verified or performed. Each activity marked must be fully explained below at section 3. Inspection Details.
Mechanical testing ( charpy impact, tensile, guided
Material identification and traceability
bends)
Review of Welding Procedure Specification and Procedure Pressure/Leak test (hydro-static, air, helium, etc.)
Control of welding consumables (filler metals, rods, wire, etc.) Vibration Noise
Full dimensional inspection for compliance with design drawing Operational Test
Any holder of this inspection report is advised that information contained hereon reflects the companys findings at the date and time of the inspection only and within the limits of
clients instructions and specifications, if any. The companys sole responsibility is to its client and this document does not exonerate parties to a transaction from exercising all their
rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders
may be prosecuted to the fullest extent of the law
NATIONAL INSPECTION AND TECHNICAL TESTING CO. LTD. (FAHSS / TV NORD SAUDI ARABIA) P.O BOX 10771 JUBAIL 31961
JUBAIL: (03) 340 7607 / 7608 / 7609 FAX: (03) 340 7605 - JEDDAH: (02) 652 0212 / 614 3438 FAX: (02) 652 0822
YANBU: TEL / FAX (04) 325 1475 EMAIL: info@fahsstuv.com
Page 2 of 5
Review of QC records
Witness of Hydro Static test Inspection for the equipment Coil No. 69, 70, 71 &72:
Hydrostatic test Inspection witnessed of Radiant coil work no 13C0011, Coil no 69, 70, 71, 72 as per approved drawing found satisfactory
and accepted.
Hydro test carried out as per approved procedure EG13C006-1 and approved Drawing No 03102CB0001 the equipment test in Horizontal
condition.
Water quality Lab test reports verified the actual values are meet the requirements.
Temperature of the water during hydro test measured @ 20 C and found within acceptable limits as per approval procedure.
Pressure Gauge reading measured at Top of the offered Radiant coil and actual obtained pressure readings are 90 bars as per requirement
of the requirement drawing 87.3 bar. Pressure gauge had valid calibration sticker and same has been verified with the original calibration
certificate.
Review of RT film of Tube to Tube & coils 100% as per the approved drawings, approved procedure, acceptable criteria ASTM
E446, EG13COO6-1 C3.6 Radiography films are found satisfactory and accepted.
All inspection reports were reviewed endorsed.
Reviewed Liquid penetrant test inspection record As per ASME SEC VIII Div-1, Appendix 8 and reviewed report found acceptable.
.
Visual Inspection of dimensional Tube assembly report was reviewed as per MSS-SP-55 and Approved Drawing of each fitting found
acceptable..
All inspection reports were reviewed endorsed.
Page 3 of 5
4. Attachments: (Each attachment must reference the corresponding Attachment no., TV Assignment no., and clients PO no.)
Inspectors Signature:
Any holder of this inspection report is advised that information contained hereon reflects the companys findings at the date and time of the inspection only and within the limits of
clients instructions and specifications, if any. The companys sole responsibility is to its client and this document does not exonerate parties to a transaction from exercising all their
rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may
be prosecuted to the fullest extent of the law
NATIONAL INSPECTION AND TECHNICAL TESTING CO. LTD. (FAHSS / TV NORD SAUDI ARABIA) P.O BOX 10771 JUBAIL 31961
JUBAIL: (03) 340 7607 / 7608 / 7609 FAX: (03) 340 7605 - JEDDAH: (02) 652 0212 / 614 3438 FAX: (02) 652 0822
YANBU: TEL / FAX (04) 325 1475 EMAIL: info@fahsstuv.com
Page 4 of 5
5. PHOTOS
Hydro Test Radiant coil no-71. Hydro Test Radiant coil no-69.
Hydro Test Radiant coil no-72. Full View of Hydro Test Radiant coil no-70.
Any holder of this inspection report is advised that information contained hereon reflects the companys findings at the date and time of the inspection only and within the limits of
clients instructions and specifications, if any. The companys sole responsibility is to its client and this document does not exonerate parties to a transaction from exercising all their
rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders
may be prosecuted to the fullest extent of the law
NATIONAL INSPECTION AND TECHNICAL TESTING CO. LTD. (FAHSS / TV NORD SAUDI ARABIA) P.O BOX 10771 JUBAIL 31961
JUBAIL: (03) 340 7607 / 7608 / 7609 FAX: (03) 340 7605 - JEDDAH: (02) 652 0212 / 614 3438 FAX: (02) 652 0822
YANBU: TEL / FAX (04) 325 1475 EMAIL: info@fahsstuv.com
Page 5 of 5
Any holder of this inspection report is advised that information contained hereon reflects the companys findings at the date and time of the inspection only and within the limits of
clients instructions and specifications, if any. The companys sole responsibility is to its client and this document does not exonerate parties to a transaction from exercising all their
rights and obligations under the transaction documents. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders
may be prosecuted to the fullest extent of the law
NATIONAL INSPECTION AND TECHNICAL TESTING CO. LTD. (FAHSS / TV NORD SAUDI ARABIA) P.O BOX 10771 JUBAIL 31961
JUBAIL: (03) 340 7607 / 7608 / 7609 FAX: (03) 340 7605 - JEDDAH: (02) 652 0212 / 614 3438 FAX: (02) 652 0822
YANBU: TEL / FAX (04) 325 1475 EMAIL: info@fahsstuv.com
Page 6 of 5