Sei sulla pagina 1di 28

OPERATING LIMITS

Flow rates up to: 68 m3/h* SCX-DCX - SXM-DXM


Heads up to: 19 m
Max. service pressure: 10 bar
Temperature range: -20 + 130C** SINGLE AND TWIN-HEAD CIRCULATORS
Max. ambient temperature:
DN of ports:
+ 50C***
32 100
Commercial heating & air conditioning
*136 m3/h: with both heads operating in parallel
** except models 80-110N & 80-150N = 110C
2 pole - 50 Hz
*** 40C if fluid temperature >120C

19 APPLICATIONS
Commercial central heating in housing, Boiler recycling.
office buildings, greenhouses, swimming Primary loop, exchanger or heater, in secon-
pools, farms, etc. dary hot water system.
Hm
Air conditioning. All new or renovated installations.
SCX / DCX DCX / DXM
SXM / DXM

0 68 Qm /h
3
136

ADVANTAGES

Versatile circulators designed for use in


heating, air conditioning, and secondary
hot water circuits.

Cataphoresis coating of pumphousing


for a better resistance to corrosion.

Dual-voltage motors, 230-400 V. Except


models 80-110N and 80-150N = 400V.
DCX (three-phase) SCX (three-phase)
Built-in thermal overload protection of
motor.

R edesigned casing for better perfor-


mance and even quieter operation.

N ew impeller profile for optimum


efficiency.

Lower energy consumption.

Automatic venting of rotor chamber.

DCX-DXM
Standby pump available at all times.
Possibility of operating the two pumps
in parallel, for lower purchase and ope-
SXM (Single-phase) DXM (Single-phase)
rating costs.

230
V

Speed selector 3~230V


(accessories)

N.T. No 122-1/EN -Ed. 11/09-08


1
SCX-DCX - SXM-DXM

DESIGN THE 2 POLE CIRCULATOR LINES


Pump SCX -DCX
- Flanged casing*, in-line ports.
- Bosses on rear for wall mounting**. Single and twin-head circulators * Except models 80-110N & 80-150N = 3~ 400V
- Flanges fitted with pressure gauge ports. Threaded G2 and ND 40 to 100.
- New impeller profile. Three-phase, dual voltage 230-400V* motors.
* threaded ports on model SCX 32-80. Voltages according to European standards.
** drilling on request
Three-speed motors by plug-in manual selec-
Twin-head models (DCX-DXM) tor switch.
- Twin pumps in a single casing. Built-in thermal over-
- Hydraulic separation by double flap valve on load protection.
discharge end. 17 single head
models.
Motors 1 6 twin-head
- 2 pole, voltages according to European models.
standards.
- Wet rotor, self-lubricating soft bearings.
SXM -DXM
Single-phase:
- 2 speeds by plug-in selector switch, built-in Single and twin-head circulators
capacitor. Threaded G2 and ND 40 to 80.
Three-phase: Single-phase 230 V, winding motors with
- dual voltage*, 3 speeds by plug-in selector built-in capacitor.
switch coupled to voltage Voltages according to European standards.
Speeds : see table Two-speed motors by plug-in manual selec-
Windings 1-phase: 230 V tor switch.
3-phase: 230-400 V* B uilt- in thermal
Frequency: 50Hz (60Hz on request) overload protection.
Protection index: IP44 1 0 single head
Insulating category: H models.
EC conformity: CE 10 twin-head
EMC conformity: -emission: EN 61000-6-3 models.
-immunity: EN 61000-6-2
(except SCX 80-110N & 80-150N, DCX 80-110N & 80-150N)

STANDARD CONSTRUCTION MIN. SUCTION


PRESSION MINIPRESSURE (m w.c.)
A LASPIRATION ACCORDING
(MCE) TO OPERATINGDE
SELON TEMPERATURE TEMPERATURE
FONCTIONNEMENT
MODeLs
MODLE 3-phase
TRI 1-phase
MONO 50C 95C 110C 130
Main parts Material
SCX DCX SXM DXM
Pump casing Cast iron EN-GJL-250
32-80 0,5mCE 5mCE 11mCE 24mCE
Impeller Composite PP-50%GF
40-40 0,5mCE 5mCE 11mCE 24mCE
Shaft SS X46Cr13
40-80 0,5mCE 5mCE 11mCE 24mCE
Rotor can SS
40-110 0,5mCE 5mCE 11mCE 24mCE
Soft bearings Graphite
50-25 3mCE 10mCE 16mCE 29mCE
Casing gasket Ethylene-Propylene
50-50 3mCE 10mCE 16mCE 29mCE
50-90 3mCE 10mCE 16mCE 29mCE
IDENTIFICATION 50-110 3mCE 10mCE 16mCE 29mCE
65-25 3mCE 10mCE 16mCE 29mCE
SCX 65-25 65-50 3mCE 10mCE 16mCE 29mCE

SCX: single pump, 3-phase 65-90 3mCE 10mCE 16mCE 29mCE

DCX: twin pump, 3-phase 65-110 3mCE 10mCE 16mCE 29mCE


80-25 3mCE 10mCE 16mCE 29mCE
SXM: single pump, 1-phase
80-50 3mCE 10mCE 16mCE 29mCE
DXM: twin pump, 1-phase
80-110 9mCE 18mCE 23mCE
DN of ports (mm) 80-150 9mCE 18mCE 23mCE
Total manometric head (dm) nominal flow 100-50 3mCE 10mCE 16mCE 29mCE
NOTA:
NB: En altitude,
At high ajouter
altitudes, 0,60mmfor
add 0.60 parevery
tranche
500de
m.500 m.m10,2
(10.2 w.c.MCE = 1 bar.
= 1 bar)

2
SCX-DCX - SXM-DXM

COMPETITIVE CHANGES
Three-phase motor terminal box

Connection to 3~ 230V*

Rotor-shaft Single-phase, 2 pole motor Three-phase, 2 pole motor

Dual-voltage, 3-phase 230-400V*


With plug-in speed selector coupled to ope-
rating voltage (see opposite).
Built-in thermal overload probe protects win-
ding at all speeds by external relay.
New, more attractive terminal box.
Electrical connections via terminal box, cable
glands on right or left side.
Display of rotation direction of motor, speed
selected, and operating voltage.
New data plate with information about all
electrical values of the installed circulator.
Very quiet motors.
T he hollow shaft ensures a circulation of
water that allows automatic venting and * except models 80-110N & 80-150N = 3~ 400V

lubrication.
Permanent venting of the rotor chamber, eli-
minating manual air bleed when starting.
C ontinuous lubrication of the rear soft
bearing.
No more blockage of shaft.

Impeller

New profile for high efficiency, lower energy


consumption and noise reduction.

3
SCX-DCX - SXM-DXM

GENERAL SELECTION GRAPHS AT MAXIMUM SPEED


Hm

20
SCX`
2 POLE 18
3-PHASE
50 Hz 16
50-1
10

80
14

-15
40
-1

0
10
12

80
65-

-11
90

0
65
10

-11
80-50
40- ,100-

0
80 50
8 50
-9
0
6 65
50- -5
25 0
4
40
-4

80
32-

50
0

-2
-50
65
80
2

5
-25
0
0,1 0,2 0,3 0,4 0,8 1,2 1,6 4 8 12 16 20 24 32 40 80 Q m/h

Hm

16
SXM
2 POLE
1-PHASE 14
50 Hz
12
32-80
40
-11

10 40-8
0

0
50-9
0
8 65-50
50-50

6
40
-4
0
4 50
-25
80
65

-25

2
-25

0
0,2 0,3 0,4 0,6 1 2 3 4 6 10 20 30 40 60 Q m/h

MOUNTING POSITION

4
SCX-DCX - SXM-DXM

GENERAL SELECTION GRAPHS AT MAXIMUM SPEED


Hm

20
DCX
2 POLE 18
3-PHASE
50 Hz 16
50-1
10

80
14

-15
40
-1

0
10
12

80
65-

-11
90

0
65
10

-11
80-50
40- ,100-

0
80 50
8 50
-9
0
6 65
50- -5
25 0
4
40
-4

80
32-

50
0

-2
-50
65
80
2

5
-25
0
0,1 0,2 0,3 0,4 0,8 1,2 1,6 4 8 12 16 20 24 32 40 80 Q m/h

Hm

16
DXM
2 POLE
1-PHASE 14
50 Hz
12
32-80
40
-11

10 40-8
0

0
50-9
0
8 65-50
50-50

6
40
-4
0
4 50
-25
80
65

-25

2
-25

0
0,2 0,3 0,4 0,6 1 2 3 4 6 10 20 30 40 60 Q m/h

MOUNTING POSITION
(A): possible mounting, but needs periodical changeover to avoid trapped air at the high point, or connection of a bleed to the port provided for it ( 1/8).

(B): Do not use with


chilled water.

(A) (B) (A)

5
SCX-DCX - SXM-DXM

SCX - SINGLE CIRCULATORS - 2 POLE - THREE-PHASE 50 Hz

0 1 2 3 4 Q m/s 0 1 2 3 Q m/s
Hm
SCX 32-80N Hm
SCX 40-40N
12 DN32 - 50Hz DN40 - 50Hz

10 6

8
4
6

4
2
2 3
3 2
1 2 1
2
1
0 0
0 2 4 6 8 10 Qm3/h 0 4 8 12 16 Qm3/h

0,0 0,5 1 1,5 2 2,5 3 Q l/s 0 1 2 3 4 5 Q l/s


0 10
1 20
2 30
3 Q
4 Imp.gpm 0 10
1 20
2 30
3 40
4 50
6
5 Q Imp.gpm
P P
kW kW

0,2 0,2

0,0 0,0
0 2 4 6 8 10 Qm3/h 0 4 8 12 16 Qm3/h

Hm 0 0,5 1 1,5 2 2,5 3 3,5 4 Q m/s Hm 0 1 2 3 4 Q m/s


16 0 1 2 3 4 Q m/s 16
SXM 40-110N SCX 40-110N
DN40 -SCX
50Hz40-80N
Hm
14 14 DN40 - 50Hz
10 DN40 - 50Hz
12 12

8 10
10

8 6 8

6 6
4
4 4

2 3
2 2 2 2 3
11 2
1
0 0 0
0 20 4 64 8 8
10 12 12
14 16 1618 20
Q m/h Qm3/h 0 2,5 5 7,5 10 12,5 15 17,5 Q m/h
0 1 2 3 4 5 Q l/s 0 1 2 3 4 5 Q l/s
0 0 201 2 40 3 460 Q 5Imp.gpm 6
Q l/s 0 20 40 60 Q Imp. gpm
1 1
P 0 20 40 60
80 Q Imp.gpm P
kW kW
0,8 P
0,75
kW

0,6 0,4 0,5

0,4 0,2 0,25

0,2 0,0 0
0 20 4 64 8 8
10 12 12
14 16 1618 20
Q m/h Qm3/h 0 2,5 5 7,5 10 12,5 15 17,5 Q m/h

6
SCX-DCX - SXM-DXM

SCX - SINGLE CIRCULATORS - 2 POLE - THREE-PHASE 50 Hz

0,0 0,5 1,0 1,5 2,0 2,5 3,0 Q m/s 0 1 2 3 4 Q m/s


Hm
SCX 50-25N Hm
SCX 50-50N
DN50 - 50Hz DN50 - 50Hz
5

4 6

3
4

3 2 3
1 2 2
1 1

0 0
0 4 8 12 16 20 Qm3/h 0 5 10 15 20 25 Qm3/h

0 1 2 3 4 5 6 Q l/s 0 2 4 6 8 Q l/s

0
20 20
40 40
60 60
80 Q Imp.gpm 0 20 40 60 80 Q Imp.gpm
P P
kW kW

0,2 0,4

0,1 0,2

0,0 0,0
0 4 8 12 16 20 Qm3/h 0 5 10 15 20 25 Qm3/h

Hm
0 1 2 3 4 Q m/s 18
SCX 50-110N
Hm
SCX 50-90N 16 DN40 - 50Hz
10 DN50 - 50Hz
14

8 12

10
6
8

4 6

4
2 3 3
2 2
1 2
1
0 0
0 5 10 15 20 25 30 Qm /h
3
0 5 10 15 20 25 30 35 40 Q m/h
2 5 8 10 Q l/s
0 2 4 6 8 Q l/s
10 50 100 130 Q Imp.gpm
Q Imp.gpm 1,8
0 20 40 60 80 90 P1,6
P kW
1,4
kW 1,2
1,0
0,8
0,4 0,6
0,4
0,2
0,0 0,0
0 5 10 15 20 25 30 Qm3/h 0 5 10 15 20 25 30 35 40 Q m/h

7
SCX-DCX - SXM-DXM

SCX - SINGLE CIRCULATORS - 2 POLE - THREE-PHASE 50 Hz

0,0 0,5 1,0 1,5 2,0 2,5 3,0 Q m/s 0,0 0,5 1,0 1,5 2,0 2,5 3,0 Q m/s
Hm
SCX 65-25N Hm
SCX 65-50N
DN65 - 50Hz DN65 - 50Hz
8
6

4
4

2
2
3 3
2 2
1 1
0 0
0 10 20 30 Qm3/h 0 10 20 30 40 Qm3/h

0 2 4 6 8 10 Q l/s 0 2 4 6 8 10 Q l/s

0 20 40 60 80 100 120 Q Imp.gpm 0 40 80 100 Q Imp.gpm


120
P P
kW kW

0,4
0,4
0,2

0 0,0
10 20 30 40 0 10 20 30 40 Qm /h
3
Qm3/h

0 1 2 3 4 Q m/s
SCX 65-110N
Hm
Hm
SCX 65-90N 14 DN65 - 50Hz
DN65 - 50Hz
12
12

10
10

8 8

6 6

4 4

2 2
2 3 3
1 1 2
0 0
0 10 20 30 40 50 Qm3/h 0 10 20 30 40 50 Q m/h
0 5 10 15 Q l/s
0 2 4 6 8 10 12 Q l/s Q Imp.gpm
0 50 100 150
1,8
0 40 80 100 120 Q Imp.gpm P 1,6
P kW1,4
kW 1,2
1,0 1
0,8
0,6
0,5 0,4
0,2
0,0 0
0 10 20 30 40 50 Qm /h
3
0 10 20 30 40 50 Q m/h

8
SCX-DCX - SXM-DXM

ScX - SINGLE CIRCULATORS - 2 POLE - THREE-PHASE 50 Hz

0,0 0,5 1,0 1,5 2,0 2,5 Q m/s 0 1 2 3 Q m/s


Hm
SCX 80-25N
Hm
SCX 80-50N
7 DN80 - 50Hz DN80 - 50Hz
10
6

5 8

4 6

3
4
2
2
1 3
3 2
2 1
1
0 0
0 10 20 30 40 Qm3/h 0 10 20 30 40 50 60 Qm3/h

0 2 4 6 8 10 12 14 Q l/s 0 4 8 12 16 Q l/s

0 40 80 120 160 Q Imp.gpm 0 50 100 150 200 Q Imp.gpm


P P
kW kW

0,4 1,0

0,2 0,5

0,0 0,0
0 10 20 30 40 Qm3/h 0 10 20 30 40 50 60 Qm3/h

20
Hm
SCX 80-110N Hm SCX 80-150N
16 DN80 - 50Hz 18 DN80 - 50Hz
16
14
14
12
12
10
10
8
8
6
6
4 4

2 2

0 0
0 10 20 30 40 50 60 70 Q m/h 0 10 20 30 40 50 60 70 80 Q m/h
0 5 10 15 20Q l/s 0 5 10 15 20 Q l/s
Q Imp.gpm 0 50 100 150 200 250 Q Imp.gpm
0 50 100 150 200 250
3 3,5
P P
kW 2,5 kW 3
2 2,5
2
1,5
1,5
1
1
0,5 0,5
0 0
0 10 20 30 40 50 60 70 Q m/h 0 10 20 30 40 50 60 70 80 Q m/h

9
SCX-DCX - SXM-DXM

ScX - SINGLE CIRCULATORS - 2 POLE - THREE-PHASE 50 Hz

0 1 2 3 Q m/s
Hm
SCX 100-50N
DN100 - 50Hz
10

2
3
2
1
0
0 10 20 30 40 50 60 Qm3/h

0 4 8 12 16 Q l/s

0 50 100 150 200 Q Imp.gpm


P
kW

1,0

0,5

0,0
0 10 20 30 40 50 60 Qm3/h

10
SCX-DCX - SXM-DXM

0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 Q m/s


DCX - TWIN CIRCULATORS - 2 POLE - THREE-PHASE
H m50 Hz
DXM 40-110N
17,5 DN40 - 50Hz
001 1 223 3 445 5 6 Q m/s 0 1 2 3 4 5 6 Q m/s
Hm
DCX 32-80N Hm15,0
DCX 40-40N
12 DN32 - 50Hz 12,5 DN40 - 50Hz
P1
10 P1 610,0 +P
+P 2
P1

P1
/P

8 7,5 PP1

/P
2

+PP

P21
22

P1
4 5,0

/P
6
2

/P
2
1
2,5
4 2
2 1
0
0 5 10 15 20 25 Q m/h
2 3
3 0 1 2 3 4 3 5 6 7 8 Q l/s
2 2 2
1 2 3 1 0 20 140 60 180 100 Q Imp.gpm
0 0
0 4 8 12 16 Qm3/h 0
2 5 10 15 20 25 Qm3/h
P
kW
001 1 234
2 3 4 5 Q l/s 0
1,5 2 4 6 8 Q l/s

02
0 04
20 06
40 0
60 Q Imp.gpm 0
20
1 20
40 40
60 60
80 80
100 Q Imp.gpm
P P
kW kW 0,5

0,4 0,4 00 5 10 15 20 25 Q m/h

0,0 0,0
0 4 8 12 16 Qm3/h 0 5 10 15 20 25 Qm3/h

0 2 4 6 Q m/s 0 1 2 3 4 5 6 7 Q m/s

Hm
DCX 40-80N
Hm
DCX 40-110N
DN40 - 50Hz 17,5 DN40 - 50Hz
10

15
8
12,5
P1
6
+P
P1 10 P1 2
+P +P
2 2
4 7,5 P1
+P
P1

2
P1

/P

3
/P

5
2
P1

P1
2

2 3 2
/P
/P

1
2 3 2 2,5
2

1
2

1
1 2 3
0 0
0 5 10 15 20 25 30 Qm3/h 0 5 10 15 20 25 30 Q m/h
0 1 2 3 4 5 6 7 8 Q l/s
0 2 4 6 8 Q l/s
0 10 20 30 40 50 60 70 80 90 100 Q lmp.gpm

0
20 20
40 40
60 60
80 80
100 100
120 Q Imp.gpm 2
P
P kW
kW 1,5

0,8 1

0,4 0,5

0,0 0
0 5 10 15 20 25 30 Qm3/h 0 5 10 15 20 25 30 Q m/h

11
SCX-DCX - SXM-DXM

DCX - TWIN CIRCULATORS - 2 POLE - THREE-PHASE 50 Hz

0 1 2 3 4 Q m/s 0 1 2 3 4 5 6 Q m/s
Hm
DCX 50-25N Hm
8 DCX 50-50N
DN50 - 50Hz DN50 - 50Hz
5
P1
P1 +P
4 /P 2 6
2 P1
+P
2
3
4

2
3
2
2 3

P1
1 2
1

/P
3 1
2 3

2
1 1 2
0 0
0 5 10 15 20 25 30 Qm3/h 0 10 20 30 40 Qm3/h

0 2 4 6 8 Q l/s 0 2 4 6 8 10 12 Q l/s

0 20 40 60 80 100 Q Imp.gpm 0 40 80 100 Q Imp.gpm


P P
kW kW

0,8
0,4

0,2 0,4

0,0 0,0
0 5 10 15 20 25 30 Qm3/h 0 10 20 30 40 Qm3/h

0 2 4 6 Q m/s
DCX 50-110N
Hm
Hm
DCX 50-90N 16 DN50 - 50Hz
10 DN50 - 50Hz
14
P1

8 12
/P

P1
P1 +P
2

10
6 +P 2
2 8

4 6 P1
+P
P1

P1
+P 2
/P

3
P1
P1

3 4
2

2 2 3
/P
/P2

2 2 2
2

2 1
1 1
3
0 0
1 2
0 10 20 30 40 50 Qm3/h 0 10 20 30 40 50 60 Q m/h
5 10 15 Q l/s
0 4 8 12 Q l/s Q Imp.gpm
50 100 150 200
0 3,5
40 80 100 120 Q Imp.gpm
P
P kW 3
kW 2,5
2
1 1,5
1
0,5
0
0 10 20 30 40 50 Qm /h
3 0
0 10 20 30 40 50 60 Q m/h

12
SCX-DCX - SXM-DXM

DCX - TWIN CIRCULATORS - 2 POLE - THREE-PHASE 50 Hz

0 1 2 3 4 5 Q m/s 0 1 2 3 4 5 Q m/s
Hm
DCX 65-25N
Hm
DCX 65-50N
DN65 - 50Hz DN65 - 50Hz
8
6

4 P1 P1
+P 4 +P
2 2

2
3 2
3

P1
P1

2 2
1

/P
1
/P

1 2 3 1 2 3

2
2

0 0
0 10 20 30 40 50 60 Qm3/h 0 20 40 60 Qm3/h

0 4 8 12 16 Q l/s 0 4 8 12 16 20 Q l/s

0 40 80 120 160 200 Q Imp.gpm 0 50 100 150 200 Q Imp.gpm


P P
kW kW

1,0
0,5
0,5

0,0 0,0
0 10 20 30 40 50 60 Qm3/h 0 20 40 60 Qm3/h

DCX 65-110N
0 2 4 6 Q m/s Hm

Hm
DCX 65-90N 14 DN65 - 50Hz
DN65 - 50Hz
12
12

10
P1

10
P1 P1+ P
/P

+P P2 1+

P1
2

8 8
+P
2

2
6 6
P1/
P1

4 4
P2
P2
/P

3
2

2 3 2 2
1 2 1
1 2
3
1 2 3
0 0
0 20 40 60 80 Qm3/h 0 20 40 60 80 100 Q m/h
10 20 30 Q l/s
0 4 8 12 16 20 24 Q l/s 100 200 300 Q Imp.gpm
Q Imp.gpm 4
0 50 100 150 200 250 P 3,5
P kW
kW 3
2,5
2 2
1,5
1 1
0,5
0
0 20 40 60 80 Qm3/h 0 0

0 20 40 60 80 100 Q m/h

13
SCX-DCX - SXM-DXM

DCX - TWIN CIRCULATORS - 2 POLE - THREE-PHASE 50 Hz

0 1 2 3 4 Q m/s 0 1 2 3 4 5 6 Q m/s
Hm
DCX 80-25N
Hm
DCX 80-50N
DN80 - 50Hz DN80 - 50Hz
10
6

5 8

4 6
P1 P1
+P +P
3 2 2
4
2
3 3

P1
2 2
P1

1 2

/P
1 1
/P

2
2 3 2 3
1
2

1
0 0
0 20 40 60 Qm3/h 0 20 40 60 80 100 Qm3/h

0 4 8 12 16 20 Q l/s 0 5 10 15 20 25 30 Q l/s

0 50 100 150 200 250 Q Imp.gpm 0 100 200 300 Q Imp.gpm

P P
kW kW

1,0 2

0,5 1

0,0 0
0 20 40 60 Qm3/h 0 20 40 60 80 100 Qm3/h

16
DCX 80-150N
Hm
Hm DCX 80-110N
14 DN80 - 50Hz 18 DN80 - 50Hz
16
12
P1 14
P1
10 P1 +P P1 +P
+P 2 12
+P 2
2 2
P1

8 10
P1
/P
P1

+P
2
P1

8
P1
/P2

6 2 P1
/P2

/P2

6 +P
4 2 3
3 4 2
2
1 1
2 2
1 23 1 2 3
0 0
0 20 40 60 80 100 120 Q m/h 0 20 40 60 80 100 120 Q m/h
10 20 30 Q l/s 10 20 30 Q l/s

100 200 300 400 Q Imp.gpm 100 200 300 400 Q Imp.gpm
7
6
P P
kW 5 kW 6
5
4
4
3 3
2 2
1 1
0 0
0 20 40 60 80 100 120 Q m/h 0 20 40 60 80 100 120 Q m/h

NB: The hydraulic curves above and on the previous pages give the hydraulic characte-
ristics for one head in operation (P1 or P2) and for both heads in parallel (P1 + P2).

14
SCX-DCX - SXM-DXM

Operation
Alternating operation Parallel operation
pump 1 or pump 2 in operation
One head on standby ensures operating reliability with no stoppage
of the installation
Operation of the pumps programmed and switched over by control box.

11 1 22 2 11 1 22 2 11 1 22 2

SXM - SINGLE CIRCULATORS - 2 POLE - SINGLE-PHASE 50 Hz

0 1 2 3 4 Q m/s 0 1 2 3 Q m/s
Hm
SXM 32-80N
Hm
SXM 40-40N
12 DN32 - 50Hz DN40 - 50Hz

10 6

8
4
6

4
2
2 2
2
1
1
0 0
0 2 4 6 8 10 Qm3/h 0 4 8 12 16 Qm3/h

0,0 0,5 1,0 1,5 2,0 2,5 Q l/s 0 1 2 3 4 Q l/s

0 10 20 30 Q Imp.gpm 0 10 20 30 40 50 Q Imp.gpm
P P
kW kW

0,2 0,2

0 0,0
0 2 4 6 8 10 Qm3/h 0 4 8 12 16 Qm3/h

15
SCX-DCX - SXM-DXM

SXM - SINGLE CIRCULATORS - 2 POLE - SINGLE-PHASE 50 Hz

0 1 2 3 4 5 Q m/s Hm 0 0,5 1 1,5 2 2,5 3 3,5 4 Q m/s H


16
Hm
SXM 40-80N SXM 40-110N
DN40 - 50Hz 14 DN40 - 50Hz
10

12
8
10
6
8

4 6

4
2
2
1
2 2
0 1
0 4 8 12 16 20 Qm /h
3
0
0 2 4 6 8 10 12 14 16 18 Q m/h
0 1 2 3 4 5 6 Q l/s 0 1 2 3 4 5 Q l/s
0 20 40 60 Q Imp.gpm
0 20 40 60 Q Imp.gpm
1 1
P P
kW kW k
0,8 0
0,4
0,6 0
0,2
0,4 0
0,0
0 4 8 12 16 20 Qm /h
3

0,2
0 2 4 6 8 10 12 14 16 18 Q m/h

0,0 0,5 1,0 1,5 2,0 2,5 3,0 Q m/s 0 1 2 3 4 Q m/s


Hm
SXM 50-25N Hm
SXM 50-50N
50-25N
DN50 - 50Hz DN50 - 50Hz
5

4 6

3
4

2 2
2
1 1
1

0 0
0 5 10 15 20 Qm3/h 0 5 10 15 20 25 Qm3/h

0 1 2 3 4 5 6 Q l/s 0 2 4 6 8 Q l/s

0 20 40 60 Q Imp.gpm 0 20 40 60 80 Q Imp.gpm
P P
kW kW

0,2 0,4

0,1 0,2

0,0 0,0
0 5 10 15 20 Qm3/h 0 5 10 15 20 25 Qm3/h

16
SCX-DCX - SXM-DXM

SXM - SINGLE CIRCULATORS - 2 POLE - SINGLE-PHASE 50 Hz

0 1 2 3 4 Q m/s 0,0 0,5 1,0 1,5 2,0 2,5 3,0 Q m/s


Hm
SXM 50-90N Hm
SXM 65-25N
DN50 - 50Hz DN65 - 50Hz

8
6

6
4
4

2
2
2
1 2
1
0 0
0 5 10 15 20 25 30 Qm3/h 0 10 20 30 Qm3/h

0 2 4 6 8 Q l/s 0 2 4 6 8 10 Q l/s

0 20 40 60 80 100 Q Imp.gpm 0 20 40 60 80 100 120 Q Imp.gpm


P P
kW kW

0,4
0,4
0,2

0,0 0,0
0 5 10 15 20 25 30 Qm3/h 0 10 20 30 Qm3/h

0,0 0,5 1,0 1,5 2,0 2,5 3,0 Q m/s 0,0 0,5 1,0 1,5 2,0 2,5 Q m/s
Hm
SXM 65-50N Hm
SXM 80-25N
DN65 - 50Hz DN80 - 50Hz
8
6

4
4

2
2

2 1 2
1
0 0
0 10 20 30 40 Qm3/h 0 10 20 30 40 50 Qm3/h

0 2 4 6 8 10 Q l/s 0 4 8 12 Q l/s

0 40 80 120 Q Imp.gpm 0 40 80 100 120 Q Imp.gpm


P P
kW kW

0,4 0,4

0,0 0,0
40 Qm /h
3
0 10 20 30 0 10 20 30 40 50 Qm3/h

17
SCX-DCX - SXM-DXM

DXM - TWIN CIRCULATORS - 2 POLE - SINGLE-PHASE 50 Hz

0 1 2 3 4 5 6 Q m/s 0 1 2 3 4 5 6 Q m/s
Hm
DXM 32-80N Hm
DXM 40-40N
12 DN32 - 50Hz DN40 - 50Hz

10 6

8 P1 P1
+P +P
2 4 2
6
P1

P1
4
/P

/P
2

2
2 2 2
2
1 2 1 1 1
0 0
0 4 8 12 16 Qm3/h 0 5 10 15 20 25 Qm3/h

0 1 2 3 4 5 Q l/s 0 2 4 6 8 Q l/s

0 20 40 60 Q Imp.gpm 0 20 40 60 80 Q Imp.gpm
P P
kW kW

0,4 0,4

0,0 0,0
0 4 8 12 16 Qm3/h 0 5 10 15 20 25 Qm3/h

0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 Q m/s

DXM 40-110N
Hm
0 2 4 6 8 Q m/s
Hm
DXM 40-80N 17,5 DN40 - 50Hz
DN40 - 50Hz
10 15,0

8 12,5
P1
10,0 +P
6 P1 2
+P
2 7,5 P1
+P
P1

4 2
P1
/P

5,0 2
P1

/P

2
2

1 1
/P

2
2,5
2

1 2
1 2
0 0
0 10 20 30 Qm /h
3 0 5 10 15 20 25 Q m/h
0 1 2 3 4 5 6 7 8 Q l/s
0 2 4 6 8 10 Q l/s 0 20 40 60 80 100 Q Imp.gpm
2
0 20 40 60 80 100 120 Q Imp.gpm P
P kW
1,5
kW
1,0
1

0,5
0,5

0,0 0
0 10 20 30 Qm3/h 0 5 10 15 20 25 Q m/h

18

0 1 2 3 4 5 6 7 Q m/s
Hm
SCX-DCX - SXM-DXM

DXM - TWIN CIRCULATORS - 2 POLE - SINGLE-PHASE 50 Hz

0 1 2 3 4 Q m/s 0 1 2 3 4 5 6 Q m/s
Hm
DXM 50-25N Hm
DXM 50-50N
DN50 - 50Hz DN50 - 50Hz
5

6
4 P1
+P
P1 2
P1

3 +P 4
2
/P
2

P1
2 2

/P
2
2 1

2
1 1
2 1 2
1
0 0
0 5 10 15 20 25 30 Qm3/h 0 10 20 30 40 Qm3/h

0 2 4 6 8 Q l/s 0 2 4 6 8 10 12 Q l/s

0 20 40 60 80 100 Q Imp.gpm 0 40 80 120 Q Imp.gpm


P P
kW kW
1,0
0,4
0,5
0,2

0,0 0,0
0 5 10 15 20 25 30 Qm3/h 0 10 20 30 40 Qm3/h

0 2 4 6 Q m/s 0 1 2 3 4 5 Q m/s
Hm
DXM 50-90N Hm
DXM 65-25N
DN50 - 50Hz DN65 - 50Hz

8
6

6 P1
P1
+P +P
2 4 2
4
P1
P1

2
/P
/P

2
2
2
2

2
1 1
1 2 1 2
0 0
0 10 20 30 40 50 Qm3/h 0 10 20 30 40 50 60 Qm3/h

0 4 8 12 Q l/s 0 4 8 12 16 Q l/s

0 40 80 120 160 Q Imp.gpm 0 40 80 120 160 200 Q Imp.gpm


P P
kW kW
1,0
1,0

0,5 0,5

0,0 0,0
60 Qm /h
3
50 Qm /h
3
0 10 20 30 40 0 10 20 30 40 50

19
SCX-DCX - SXM-DXM

DXM - TWIN CIRCULATORS - 2 POLE - SINGLE-PHASE 50 Hz

0 1 2 3 4 5 Q m/s 0 1 2 3 4 Q m/s
Hm Hm
DXM 65-50N DXM 80-25N
DN65 - 50Hz DN80 - 50Hz
8
6

6 P1
+P
P1 4 2
+P
4 2

P1
2
2

/P
2
P1

2
1
/P

1
2

1 2 1 2
0 0
0 10 20 30 40 50 60 Qm /h
3
0 20 40 60 80 Qm3/h

0 4 8 12 16 Q l/s 0 4 8 12 16 20 Q l/s

0 50 100 150 200 Q Imp.gpm 0 50 100 150 200 250 Q Imp.gpm


P P
kW kW

1,0 1,0

0,5 0,5

0,0 0,0
0
80 Qm /h
3
0 10 20 30 40 50 60 Qm3/h 0 20 40 60

Operation
Alternating operation Parallel operation

pump 1 or pump 2 in operation Parallel operation of both heads for the flowrate required, allows subs-
One head on standby ensures operating reliability with no stoppage tantially lower purchase and operating costs.
of the installation A single head in operation provides about 85% of the capacity the
Operation of the pumps programmed and switched over by control box. installation needs during the heating season.
The maximum hydraulic performance needed is delivered by parallel
operation of both heads.
A control box is used for programming.

11 12 2 2 11 12 2 2 11 12 2 2

20
SCX-DCX - SXM-DXM

DIMENSIONS - SCX - THREE-PHASE 50 Hz


b4 b5 B
R1/8" M10 x 20

l1

y2
l2

y1
l0

R1/8"
b1 b2 a2 a1
b4 b5 SCX32-80
M 1:2
SXM32-80
n x L1
nx L n x L2

l2

l1
D
k

k1
k2

l0
DN
b1 b2 a2 a1
DN dd
d f2 f1
f2 f1 A
D
(G2")

flanges PN
BRIDES PN 6 6/ 10
/ 10COMBIFLANGE
COMBIFLANGE flanges
BRIDES PN
PN10
10/ /16
16EN
EN1092-2
1092-2
DN flanges
BRIDES D k1 k2 d holes
trous holes
trous DN flanges
BRIDES D k d holes
trous
mm mm mm mm n x L1 n x L2 mm mm mm n x L
40 PN 6 / 10 150 100 110 84 4 x 14 4 x 19 80 PN 10 200 160 132 8 x 19
50 PN 6 / 10 165 110 125 99 4 x 14 4 x 19 100 PN 10 220 180 156 8 x 19
65 PN 6 / 10 185 130 145 118 4 x 14 4 x 19

masse
mass
Reference
Order reference
Commande DN l0 l1 l2 a1 a2 b1 b2 b4 b5 f1 f2 y1 y2 Schma
drawing
approx.
env.
orifices
ports mm mm mm mm mm mm mm mm mm mm mm mm mm kg
SCX32-80N 32 180 90 108 172 45 69 69 69 69 60 60 - - 7 A
SCX40-40N PN6/10 40 250 125 108 193 46 78 68 69 69 65 65 220 110 12 B
SCX40-80N PN6/10 40 250 125 115 216 59 90 80 69 69 65 65 220 110 16 B
SCX40-110N PN6/10 40 250 125 125 258 55 99 86 69 69 65 65 220 110 21 B
SCX50-25N PN6/10 50 280 140 108 200 53 94 68 69 69 70 70 220 110 14 B
SCX50-50N PN6/10 50 280 140 115 224 65 91 77 69 69 70 70 250 125 18 B
SCX50-90N PN6/10 50 280 140 115 222 71 101 87 69 69 70 75 250 125 19 B
SCX50-110N PN6/10 50 340 170 125 235 81 105 90 69 69 75 83 310 155 26 B
SCX65-25N PN6/10 65 340 170 115 235 67 110 89 69 69 80 80 310 155 22 B
SCX65-50N PN6/10 (450W) 65 340 170 115 235 67 110 89 69 69 80 80 310 155 24 B
SCX65-90N PN6/10 65 340 170 125 254 81 118 98 69 69 80 80 310 155 28 B
SCX65-110N PN6/10 65 340 170 125 254 81 118 98 69 69 80 80 310 155 29 B
SCX80-25N PN10 (450W) 80 360 180 115 227 80 116 89 69 69 90 90 330 165 26 B
SCX80-50N PN10 80 360 180 125 258 95 135 108 69 69 90 98 330 165 31 B
SCX80-110N PN10 80 360 180 150 316 89 129 108 69 69 90 90 330 165 42 B
SCX80-150N PN10 80 360 180 150 316 89 129 108 69 69 90 90 330 165 45 B
SCX100-50N PN10 100 360 180 125 258 95 135 108 69 69 90 98 330 165 35 B

21
SCX-DCX - SXM-DXM

ELECTRICAL DATA - SCX - THREE-PHASE 50 Hz

Reference
Order reference
Commande EEI P2 Vitesse
speed Moteur
Motor intensit
current in
enAA Motorhead
Rf. Commande
position P1 sous
3 phase
TRI Order
Bloc-Moteur
reference
W tr/mn
rpm Wmin Wmax 230V 400V
3 2600 195 400 1.37 0.79
SCX32-80N D 180 2 2200 145 280 0.84 0.49 BMCX32-80N
1 1800 120 200 0.61 0.35
3 2600 220 370 1.31 0.76
SCX40-40N PN6/10 C 180 2 2100 165 260 0.81 0.47 BMCX40-40N
1 1800 130 185 0.57 0.33
3 2800 300 585 2.02 1.17
SCX40-80N PN6/10 C 350 2 2500 230 465 1.43 0.82 BMCX40-80N
1 2200 200 365 1.12 0.65
3 2800 500 905 3.19 1.84
SCX40-110N PN6/10 D 570 2 2500 380 720 2.25 1.30 BMCX40-110N
1 2200 330 585 1.82 1.05
3 2650 250 330 1.23 0.71
SCX50-25N PN6/10 D 180 2 2200 190 240 0.76 0.44 BMCX50-25N
1 1900 150 180 0.56 0.32
3 2800 360 610 2.06 1.19
SCX50-50N PN6/10 C 350 2 2450 285 470 1.43 0.83 BMCX50-50N
1 2150 245 375 1.14 0.66
3 2700 450 880 3.0 1.73
SCX50-90N PN6/10 C 450 2 2300 330 680 2.09 1.2 BMCX50-90N
1 2000 280 500 1.54 0.89
3 2800 1060 1570 5.43 3.13
SCX50-110N PN6/10 C 1100 2 2500 830 1260 3.90 2.25 BMCX50-110N
1 2200 720 1005 3.14 1.81
3 2750 420 610 2.06 1.19
SCX65-25N PN6/10 C 350 2 2350 340 480 1.47 0.85 BMCX65-25N
1 2050 290 370 1.14 0.66
3 2650 525 845 2.89 1.67
SCX65-50N PN6/10 (450W) C 450 2 2250 410 630 1.91 1.1 BMCX65-50N
1 1950 340 470 1.44 0.83
3 2800 1000 1450 5.07 2.93
SCX65-90N PN6/10 C 1100 2 2550 810 1180 3.64 2.1 BMCX65-90N
1 2250 700 960 3.0 1.74
3 2850 1170 1685 5.91 3.41
SCX65-110N PN6/10 C 1300 2 2650 925 1425 4.38 2.53 BMCX65-110N
1 2400 815 1210 3.78 2.18
3 2700 560 730 2.65 1.53
SCX80-25N PN10 (450W) C 450 2 2400 430 560 1.74 1.0 BMCX80-25N
1 2100 350 440 1.36 0.79
3 2800 1070 1570 5.33 3.08
SCX80-50N PN10 C 1100 2 2500 870 1280 3.91 2.26 BMCX80-50/100-50N
1 2150 750 1010 3.13 1.81
3 2900 1600 2400 - 4.85
SCX80-110N PN10 C 1800 2 2700 1300 2000 - 3.63 BMCX80-110N
1 2450 1160 1680 - 3.25
3 2900 2050 3120 - 6.10
SCX80-150N PN10 C 2200 2 2750 1670 2650 - 4.80 BMCX80-150N
1 2500 1480 2270 - 4.35
3 2800 1070 1570 5.33 3.08
SCX100-50N PN10 C 1100 2 2500 870 1280 3.91 2.26 BMCX80-50/100-50N
1 2150 750 1010 3.13 1.81

22
SCX-DCX - SXM-DXM

DIMENSIONS - DCX - THREE-PHASE 50 Hz


b4 b5 z1

l1
l2

y2
l0

y1
b1 b2 a2 a1 M10x20
R1/8" * except models
n x L
n x L1
n x L2
DN
d

k1
k2

DN
k d
D f2 f1
D

flanges PN
BRIDES PN 6 6/ 10
/ 10COMBIFLANGE
COMBIFLANGE flanges
BRIDES PN
PN10
10/ /16
16EN
EN1092-2
1092-2
DN flanges
BRIDES D k1 k2 d holes
trous holes
trous DN flanges
BRIDES D k d holes
trous
mm mm mm mm n x L1 n x L2 mm mm mm n x L
32 PN 6 / 10 140 90 100 76 4 x 14 4 x 19 80 PN 10 200 160 132 8 x 19
40 PN 6 / 10 150 100 110 84 4 x 14 4 x 19
50 PN 6 / 10 165 110 125 99 4 x 14 4 x 19
65 PN 6 / 10 185 130 145 118 4 x 14 4 x 19

mass
masse
Order
Reference
reference
Commande DN
DN l0 l1 l2 a1 a2
a2 b1
b1 b2
b2 b4
b4 b5
b5 z1
z1 y1
y1 y2
y2 f1f1 f2f2
approx.
env.
orifices
ports mm mm mm mm mm
mm mm
mm mm
mm mm
mm mm
mm mm
mm mm
mm mm
mm mm
mm mm
mm kg
kg
DCX32-80N PN6/10* 32 220 110 108 172 60 144 143 146 146 172 107 11 60 60 18
DCX40-40N PN6/10* 40 250 135 108 193 75 150 143 146 146 172 108 11 - - 20
DCX40-80N PN6/10* 40 250 135 115 216 75 178 172 156 156 225 132 35 - - 29
DCX40-110N PN6/10 40 250 125 125 258 65 200 195 175 175 225 132 25 65 65 40
DCX50-25N PN6/10* 50 280 155 108 200 83 178 158 156 156 225 132 25 - - 23
DCX50-50N PN6/10* 50 280 160 115 224 83 79 169 156 156 225 132 30 - - 31
DCX50-90N PN6/10* 50 280 155 115 222 83 198 192 166 166 228 157 50 - - 33
DCX50-110N PN6/10 50 340 170 119 243 86 209 200 173 173 252 184 30 - - 50
DCX65-25N PN6/10 65 340 170 115 235 81 214 201 175 175 225 180 25 80 80 37
DCX65-50N PN6/10 (450W) 65 340 170 115 235 81 214 201 175 175 225 180 25 80 80 40
DCX65-90N PN6/10 65 340 185 125 254 93 223 209 175 175 225 162 25 - - 49
DCX65-110N PN6/10 65 340 185 125 254 93 223 209 175 175 225 162 25 - - 56
DCX80-25N PN10 (450W) 80 360 180 115 227 88 226 210 184 184 280 198 33 90 90 46
DCX80-50N PN10 80 360 205 125 256 100 249 231 187 187 240 180 43 - - 55
DCX80-110N PN10 80 360 180 150 316 90 259 248 204 204 270 185 20 90 90 79
DCX80-150N PN10 80 360 180 150 316 90 259 248 204 204 270 185 20 90 90 85
* For this models, drilling on demand.

23
SCX-DCX - SXM-DXM

ELECTRICAL DATA - DCX - THREE-PHASE 50 Hz

Order reference
Reference Commande EEI P2 speed
Vitesse Motor
Moteur current in
intensit enAA Motorhead
Rf. Commande
position P1 3 phase
sous TRI Order reference
Bloc-Moteur
W rpm
tr/mn Wmin Wmax 230V 400V
3 2600 210 400 1.37 0.79
DCX32-80N PN6/10 D 180 2 2200 160 280 0.84 0.49 BMCX32-80N
1 1800 130 200 0.61 0.35
3 2600 220 370 1.31 0.76
DCX40-40N PN6/10 D 180 2 2100 165 260 0.81 0.47 BMCX40-40N
1 1800 130 185 0.57 0.33
3 2800 300 585 2.02 1.17
DCX40-80N PN6/10 C 350 2 2500 230 465 1.43 0.82 BMCX40-80N
1 2200 200 365 1.12 0.65
3 2800 500 905 3.19 1.84
DCX40-110N PN6/10 D 570 2 2500 380 720 2.25 1.30 BMCX40-110N
1 2200 330 585 1.82 1.05
3 2650 270 330 1.23 0.71
DCX50-25N PN6/10 E 180 2 2200 200 240 0.76 0.44 BMCX50-25N
1 1900 160 180 0.56 0.32
3 2800 360 610 2.06 1.19
DCX50-50N PN6/10 C 350 2 2450 285 470 1.43 0.83 BMCX50-50N
1 2150 245 375 1.14 0.66
3 2700 450 880 3.0 1.73
DCX50-90N PN6/10 D 450 2 2300 330 680 2.09 1.2 BMCX50-90N
1 2000 280 500 1.54 0.89
3 2800 1060 1570 5.43 3.13
DCX50-110N PN6/10 D 1100 2 2500 830 1260 3.90 2.25 BMCX50-110N
1 2200 720 1005 3.14 1.81
3 2750 420 610 2.06 1.19
DCX65-25N PN6/10 D 350 2 2350 340 480 1.47 0.85 BMCX65-25N
1 2050 290 370 1.14 0.66
3 2650 525 845 2.89 1.67
DCX65-50N PN6/10 (450W) D 450 2 2250 410 630 1.91 1.1 BMCX65-50N
1 1950 340 470 1.44 0.83
3 2800 1000 1450 5.07 2.93
DCX65-90N PN6/10 D 1100 2 2550 810 1180 3.64 2.1 BMCX65-90N
1 2250 700 960 3.0 1.74
3 2850 1170 1685 5.91 3.41
DCX65-110N PN6/10 D 1300 2 2650 925 1425 4.38 2.53 BMCX65-110N
1 2400 815 1210 3.78 2.18
3 2700 560 730 2.65 1.53
DCX80-25N PN10 (450W) D 450 2 2400 430 560 1.74 1.0 BMCX80-25N
1 2100 350 440 1.36 0.79
3 2800 1070 1570 5.33 3.08
DCX80-50N PN10 D 1100 2 2500 870 1280 3.91 2.26 BMCX80-50/100-50N
1 2150 750 1010 3.13 1.81
3 2900 1600 2400 - 4.85
DCX80-110N PN10 C 1800 2 2700 1300 2000 - 3.63 BMCX80-110N
1 2450 1160 1680 - 3.25
3 2900 2050 3120 - 6.10
DCX80-150N PN10 C 2200 2 2750 1670 2650 - 4.80 BMCX80-150N
1 2500 1480 2270 - 4.35

24
SCX-DCX - SXM-DXM

DIMENSIONS - SXM - SINGLE-PHASE 50 Hz


b4 b5 B
R1/8" M10 x 20 On
request

l1

y2
l2

y1
l0

R1/8"
b1 b2 a2 a1
b4 b5 SCX32-80
M 1:2
SXM32-80
n x L1
nx L n x L2

l2

l1
D
k

k1
k2

l0
DN
b1 b2 a2 a1
DN dd
d f2 f1
f2 f1 A
D
(G2")

flanges PN
BRIDES PN 66/ /10
10COMBIFLANGE
COMBIFLANGE flanges
BRIDES PN
PN10
10/ /16
16EN
EN1092-2
1092-2
DN
DN flanges
BRIDES
DD
kk 11
kk 22
dd holes
trous holes
trous DN
DN flanges
BRIDES
DD
kk
dd holes
trous
mm mm mm mm n x L1 n x L2 mm mm mm n x L
40 PN 6 / 10 150 100 110 84 4 x 14 4 x 19 80 PN 10 200 160 132 8 x 19
50 PN 6 / 10 165 110 125 99 4 x 14 4 x 19 100 PN 10 220 180 156 8 x 19
65 PN 6 / 10 185 130 145 118 4 x 14 4 x 19

masse
mass
Order
Reference
reference
Commande DN
DN l0
l0 l1
l1 l2
l2 a1
a1 a2
a2 b1
b1 b2
b2 b4
b4 b5
b5 f1
f1 f2
f2 y1
y y2
y1 drawing
schma
approx.
env.
orifices
orifices
ports mm
mm mm
mm mm
mm mm
mm mm
mm mm
mm mm
mm mm
mm mm
mm mm
mm mm
mm mm
mm mm
mm kg
kg
SXM32-80N 32 180 90 108 172 45 69 69 69 69 60 60 - - 7 A
SXM40-40N PN6/10 40 250 125 108 193 46 78 68 69 65 65 65 220 110 12 B
SXM40-80N PN6/10 40 250 125 115 216 59 90 80 69 69 65 65 220 110 16 B
SXM40-110N PN6/10 40 250 125 125 258 55 99 86 69 69 65 65 220 110 21 B
SXM50-25N PN6/10 50 280 140 108 200 53 94 68 69 69 70 70 220 110 14 B
SXM50-50N PN6/10 50 280 140 115 224 65 91 77 69 69 70 70 252 126 18 B
SXM50-90N PN6/10 50 280 140 115 222 71 101 87 69 69 70 75 252 126 19 B
SXM65-25N PN6/10 65 340 170 115 235 67 110 89 69 69 80 80 310 155 22 B
SXM65-50N PN6/10 (450W) 65 340 170 115 235 67 110 89 69 69 80 80 310 155 24 B
SXM80-25N PN10 (450W) 80 360 180 115 227 80 116 89 69 69 90 90 330 165 26 B

25
SCX-DCX - SXM-DXM

ELECTRICAL DATA - SXM - SINGLE-PHASE 50 Hz


current
Order reference EEI P2 Capacitor speed Motor Motorhead
Reference Commande EEI P2 Condensateur Vitesse Moteur intensit
in A en A Rf. Commande
position
position P1 sous Mono Bloc-Moteur
1 phase Order reference
W F tr/mn
rpm Wmin Wmax 230V
2 2600 225 410 2.05
SXM32-80N D 180 8 BMXM32-80N
1 2300 170 340 1.75
2 2650 250 390 1.93
SXM40-40N PN6/10 D 180 8 BMXM40-40N
1 2200 200 330 1,70
2 2800 430 680 3.47
SXM40-80N PN6/10 D 350 16 BMXM40-80N
1 2600 310 610 3.18
2 2800 615 945 4.57
SXM40-110N PN6/10 D 570 25 BMXM40-110N
1 2500 415 800 4.20
2 2700 280 350 1.67
SXM50-25N PN6/10 D 180 8 BMXM50-25N
1 2050 230 310 1.59
2 2800 460 690 3.49
SXM50-50N PN6/10 C 350 16 BMXM50-50N
1 2600 360 630 3.35
2 2800 515 820 3.94
SXM50-90N PN6/10 C 450 25 BMXM50-90N
1 2450 360 730 3.72
2 2800 510 660 3.39
SXM65-25N PN6/10 D 350 16 BMXM65-25N
1 2500 420 590 3,10
2 2800 580 790 3.78
SXM65-50N PN6/10 (450W) C 450 25 BMXM65-50N
1 2450 440 690 3.51
2 2800 640 800 3.85
SXM80-25N PN10 (450W) C 450 25 BMXM80-25N
1 2350 505 700 3.59

26
SCX-DCX - SXM-DXM

dIMENSIONS - DXM - SINGLE-PHASE 50 Hz


b4 b5 z1
b4b4 b5b5 z1z1

l1
l2

l1
l1
l2
l2

y2
l0

y2
y2
l0
l0

y1

y1
y1
b1 b2 a2 a1
b1b1 b2b2 M10x20
R1/8" a2a2 a1a1 M10x20
M10x20
n x L R1/8"
R1/8" * except models
nn x L
x L n x L1
n x L2 nn x L1
x L1 flanges
BRIDES PN
PN10
10/ /16
16EN
EN1092-2
1092-2
nn x L2
x L2
DN flanges
BRIDES D k d trous
holes
mm mm mm n x L
DN
d

80 PN 10 200 160 132 8 x 19


DN
d
DN
d

k1
k2

k1
k2

flanges PN
BRIDES PN 6 6/ 10
/ 10COMBIFLANGE
COMBIFLANGE
k1
k2

DN flanges
BRIDES D k1 k2 d holes
trous holes
trous
mm mm mm mm n x L1 n x L2
32 PN 6 / 10 140 90 100 76 4 x 14 4 x 19
DN
k d DN 40 PN 6 / 10 150 100 110 84 4 x 14 4 x 19
DN
D kk f2 f1 d
d 50 PN 6 / 10 165 110 125 99 4 x 14 4 x 19
DD D 65 PN 6 / 10 185 130 145 118 4 x 14 4 x 19
f2f2 Df1f1
D
masse
mass
Reference
Order reference
Commande DN l0 l1 l2 a1 a2 b1 b2 b4 b5 z1 y1 y2 f1 f2
approx.
env.
orifices mm mm mm mm mm mm mm mm mm mm mm mm mm kg
DXM32-80N PN6/10* 32 220 110 108 172 60 144 143 146 146 172 107 11 60 60 18
DXM40-40N PN6/10* 40 250 135 108 193 75 150 143 146 146 172 108 11 - - 20
DXM40-80N PN6/10* 40 250 135 115 216 75 178 172 156 156 225 132 35 - - 29
DXM40-110N PN6/10 40 250 125 125 258 65 200 195 175 175 225 132 25 65 65 40
DXM50-25N PN6/10* 50 280 155 108 200 83 178 158 156 156 225 132 25 - - 23
DXM50-50N PN6/10* 50 280 160 115 224 83 79 169 156 156 225 132 30 - - 31
DXM50-90N PN6/10* 50 280 155 115 222 83 198 192 166 166 228 157 50 - - 33
DXM65-25N PN6/10 65 340 170 115 235 81 214 201 175 175 225 180 25 80 80 37
DXM65-50N PN6/10 (450W) 65 340 170 115 235 81 214 201 175 175 225 180 25 80 80 40
DXM80-25N PN10 (450W) 80 360 180 115 227 88 226 210 184 184 280 198 33 90 90 46
* For this models, drilling on demand.

ELECTRICAL DATA - DXM - SINGLE-PHASE 50 Hz


Reference
Order reference
Commande EEI P2 Condensateur
Capacitor Vitesse
speed Moteur
Motor intensit
current in
enAA Motorhead
Rf. Commande
W F position
position P1 1 phase
sous Mono Order reference
Bloc-Moteur
W F tr/mn
rpm Wmin Wmax 230V
2 2600 260 410 2.05
DXM32-80N PN6/10 D 180 8 BMXM32-80N
1 2300 185 340 1.75
2 2650 250 390 1.93
DXM40-40N PN6/10 D 180 8 BMXM40-40N
1 2200 200 330 1.7
2 2800 430 680 3.47
DXM40-80N PN6/10 D 350 16 BMXM40-80N
1 2600 310 610 3.18
2 2800 615 945 4.57
DXM40-110N PN6/10 E 570 25 BMXM40-110N
1 2500 415 800 4.20
2 2700 295 350 1.67
DXM50-25N PN6/10 E 180 8 BMXM50-25N
1 2050 255 310 1.59
2 2800 460 690 3.49
DXM50-50N PN6/10 D 350 16 BMXM50-50N
1 2600 360 630 3.35
2 2800 515 820 3.94
DXM50-90N PN6/10 D 450 25 BMXM50-90N
1 2450 360 730 3.72
2 2800 510 660 3.39
DXM65-25N PN6/10 D 350 16 BMXM65-25N
1 2500 420 590 3.1
2 2800 580 790 3.78
DXM65-50N PN6/10 (450W) D 450 25 BMXM65-50N
1 2450 440 690 3.51
2 2800 640 800 3.85
DXM80-25N PN10 (450W) D 450 25 BMXM80-25N
1 2350 505 700 3.59

27
SCX-DCX - SXM-DXM

PRESSURE GAUGE KIT PARTICULARITES


Differential pressure gauge kit a) Electrical data
-Single-phase 230V - 50 Hz with built-in
For single and twin-head pumps capacitor.
Rapid connection without welding, to ports -Three-phase 400V or 230*V (50 Hz)
provided on flanges. * For 3~230V, use a speed selector (rf.
KIT includes: 2040641) sold as an accessory.
- 0-6 or 0-16 bar glycerin bath pressure gauge, -1 Speed selector for SCX
- isolating cocks, -2 Speed selectors for DCX
- unions and connecting tubes,
- bleed. b) Installation
Supplied in pouch with installation -Direct on piping, motor shaft always
instructions. horizontal.
Order ref.: Press kit 6 or -Connection to the installation by welded,
Press kit 16 round counter-flanges (not included).

c) Packaging
-Supplied with gaskets and bolts without
BLANK COVER counter-flanges.

d) Maintenance
Type detwin-head
type of circulateur double
circulator rfrence commande
Order reference -Replacement of motor head + hydraulic part
DCX 32-80 N DXM 32-80 N (see tables for order ref.).
DCX 40-40 N DXM 40-40 N COUV. 32

DCX 50-25 N DXM 50-25 N

DCX 40-80 N DXM 40-80 N


Option: cover + gasket OPTIONS & ACCESSORIES
DCX 50-50 N DXM 50-50 N

DCX 50-90 N DXM 50-90 N Motor protection circuit-breaker (SCX).


Blank cover with gasket for twin-head COUV. 42
Motor control and protection box (DCX).
DCX 65-25 N DXM 65-25 N
pumps Speed controller box.
DCX 65-50 N DXM 65-50 N Blank off cover (DCX).
DCX 80-25 N DXM 80-25 N Pressure gauge kit.
Welded round counter-flanges, unions.
DCX 40-110 N DXM 40-110 N
Isolating valves.
DCX 50-110 N
Anti-vibration sleeves, etc.
DCX 65-90 N COUV. 52 speed selector 3~230V
DCX 65-110 N

DCX 80-50 N

DCX 80-110 N
COUV. 72
NB (Replacement) DCX 80-150 N
References motorhead BMXM/BMCX are
complete sets with motor and assembled
impeller, not sold separately.

53, bd de la Rpublique - Espace Lumire - Bt. 6 - 78403 Chatou Cedex - FRANCE


28 (no Indigo) SALMSON Contact: +33(0)820 0000 44
Fax.: +33 (0)1 30 09 82 82|www.salmson.com

Potrebbero piacerti anche