Low-Voltage Capacitor Banks

TM

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com


Energy efficiency, as simple as VarSet

Do you need an easy solution to


immediately boost your facilitys
energy efficiency and productivity?

Are products that blend superior quality,


performance, and flexibility with
excellent value difficult to find?

Do you require the expertise, Engineered to meet your needs


support, and reach of a global leader with Whether you run a single site operation Choosing VarSet low-voltage capacitor
TM

the responsiveness of a local supplier?


oraglobe-spanning enterprise, a fast and banks is a simple and reliable wayto do
easy way to enhance competitiveness is to that. Count on VarSet equipment tobring
ensure that your power factor is corrected reliable energy efficiency to your electrical
and your electrical network is delivering infrastructure.
optimum power.

High quality power = higher productivity

30%
Power factor correction helps lower operating and capital costs, and can provide Up to
a very quick return on investment:

> Reduce capital expenses > Reduce energy losses by up to 30%.*


by up to 30%.* Optimize power consumption, reduce total better energy
Optimize electrical system capacity, avoid process energy consumption, and reduce efficiency and
oversizing, and limit redundant capacity. CO emissions.
2
lower electricity
> Reduce reactive energy billing > Improve power system and costs on your first
penalties and lower operating equipment reliability by up to 18%.* day with VarSet*
expenses by up to 10%.* Increase power quality to improve
Boost power factor to lower utility bills business performance and reduce
and reduce losses in transformers unplanned outages, as well as enhance
and conductors. the reliability and service life of electrical
devices, while reducing harmonics
stress and potential damage to your
electricalnetwork.
VarSet I I

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com


Maximizing energy efficiency gets easier
and more economical with VarSet

without power factor correction


Power Transmission
generation network

Active power Active power


Motor
Reactive power Reactive power

with power factor correction


Power Transmission
generation network

Active power Active power


Motor
Reactive power

Capacitor

Comprehensive products for multiple applications


Compensating for reactive power and harmonic distortion with VarSet capacitor banks is - Large choice of wall-mounted enclosures - Suitable capacitors for low and medium
one of the easiest ways to quickly maintain your facilitys power factor at an ideal level for from 25 to 300 kVAR harmonic level and type of loads
maximum power system efficiency and cost reduction.
Quality, reliability, and safety
Enhanced design creates superior performance
-  re-engineered power factor correction
P -  quare D by Schneider Electric built-in
S
Designed and manufactured by Square D by Schneider Electric , using advanced
TM TM

solutions ensure your installation delivers components, such as Spatial enclosures,


manufacturing methods and premium materials, VarSet capacitor banks are optimized to more for less, on-time and on-budget provide performance and safety
provide superior, end-to-end operation and value through every stage of its life cycle.
- Designed for easy installation - VarSet equipment are fully type tested
-  igh quality Square D by Schneider Electric
H

30%
Protection, durability, and safety you can trust Up to Up to

10%
components provide improved performance
and robustness
With decades of power factor correction more reliable, and your electrical environment
expertise behind it, VarSet is a complete safer. VarSet capacitor banks are suitable
range of high-quality, wall-mounted capacitor for new construction or retrofit applications
energy loss lower operating
banks for fixed and automatic compensation. in virtually any commercial, industrial, and
reduction* expenses*
Choose VarSet to make your business utility enterprise.
moreprofitable, your power infrastructure

II I VarSet *Performance reflects actual customer experience, your results may vary depending on your environment. VarSet I III

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com


Engineered for superior performance
and long-term value

The entire VarSet range offers a unique, Reliability and durability Safety
simple, cost-effective, wall-mounted
capacitor system that will help reduce > Dependable performance > Protection
your utility bills and will not take up any - multicapacitor architecture - step protection with circuit
floor space in your electrical rooms. - s tep switching with special breaker to help ensure stage
design contactors overload protection that cannot
Unlike standard floor-mounted systems - overheating protection and alarm be achieved with HRC fuses
that take up floor space, these systems for detuned reactors - thermal monitoring device
can be mounted above existing - earthing studs welded to the frame - incoming circuit breaker
equipment or on any free wall space. and door protection (optional)
Choose from standard automatic type - rotary handle (in when incoming
systems or detuned for areas with high > Majority of internal circuit breaker is used)
concentration of electronic loads that components are Square D
cause harmonics on the network. by Schneider Electric products > Robust enclosure
- NEMA 1 for indoor application
Simplicity - IK10 protection against
mechanical shocks
> Easy installation - high-quality welding and finish
- compact enclosure up to 300 kVAR
- top cable connections > Tested and certified
- easily accessible gland plates for power - compliant to CSA 22.2 No. 190
cables entry and connections - compliant to UL810
- mounting brackets for easy wall mounting

> Ease-of-use and maintenance


- easy programming and commissioning
ISO
14000
with Varlogic controller
TM

- simple replacement or retrofit of


VarPlusCan capacitors
quality certified
> Straightforward EMS integration manufacturing
- Modbus communication protocol
(Varlogic NRC12 option) for integration
with building management and energy
monitoring systems

Assembled in USA
Assembled in the USA
does not serve as an
expressed or implied
certification that this
product is compliant
with the Buy American
Act (BAA) Regulations
as defined in the
U.S. Governments
Federal Acquisitions
Regulations (FAR).

IV I VarSet VarSet I V

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com


For your future performance, Find out more about
choose the leader Power Quality solutions

We deliver smart and cost-effective solutions to improve your efficiency

> Reactivar, low-voltage capacitor banks

VLVAW3N wall-mounted

Find out more, visit


www.schneider-electric.com
and download
Quality, expertise, and support you can count on 5800BR0801
How can power factor correction Consult the power

We supply quality products, integrated solutions, and comprehensive services around the
and harmonic filtering be part quality solution experts.
of your energy efficiency program?

world. Our proven expertise, strong local presence, and reputation for quality ensure all your
projects produce exceptional value. From custom engineering, end-to-end support, and Make the most of

value-added tools, weve got you covered. > AccuSine , Active Harmonic Filtering
your energy SM

TM

New projects Maintenance


and services contracts Find out more, visit
- Engineered solution, location, design, www.schneider-electric.com
compensation, and filtering - Specialists close to your business and download
- Preventive maintenance/turnkey contracts 5860BR0901

100%
ReactiVar Low Voltage

Existing installations Capacitor Banks


Streamlining your electrical network's capacity

- Harmonics diagnosis
Training commitment
- Power monitoring
- Preventive maintenance/operation to quality
- Revamping

Decommissioning Find out more, visit


www.schneider-electric.com
and recycling management
Accusine and download
AMTED109015EN
- Dismantling Power factor correction

- Recovery AccuSine
Harmonic filtering and reactive power
compensation

- Recycling
Catalogue
2012

PE90001
VI I VarSet VarSet I VIII

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com


VarSet Offer Contents

Energy Choice of Compensation Type

Construction of References Principle


2

Efficiency
Offer Overview 4

Offer Range 6

General Characteristics 8

Physical and Electrical Steps 9

VarSet Components 10

Dimensions and Weights 12

Immediate
Savings

1
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
Choice of Compensation Type Construction of References
Principle

Devices using power electronics (variable speed drives, rectifiers, UPS, V L V A W 2 N 6 6 1 0 0 A A


arc furnaces, fluorescent lamps, etc.) generate harmonic currents in
Used to differentiate
electrical networks. Equipment type Voltage Frequency Power
incomer
Such harmonics can interfere with the operation of many devices, including
VLVAW2N:
capacitors, which are highly sensitive to harmonics. 6 = 480 V 6 = 60 Hz 100 = 100 kVAR AA = lugs
small-size standard
A high level of harmonic pollution causes capacitors to overheat and age
VLVAW3N:
prematurely (breakdown). 7 = 600 V AB = incoming CB
mid-size standard
Different types of compensation must be chosen according to the power of
VLVAF4P: detuned
the harmonic generators: standard or detuned. It can be selected as follows:
VLVFF4P: fixed detuned

Examples
b VLVAF4P76200AB = VarSet Detuned, 600 V, 60 Hz, 200 kVAR with
Calculated ratio Qc/Sn > 20% incoming circuit breaker

No Yes VarSet detuned

TDDi < 8%
THD(V) < 3%

No Yes VarSet standard

TDDi < 20%


THD(V) < 7%
What are these ratios?
> The Total Current Demand Distortion (TDDi)
ratio is harmonic current distortion against the
full load (demand) level.
No Yes
> The percentage of Total Harmonic Voltage
Distortion (THD(V)) is measured at the
transformer secondary, at maximum load
and without capacitors.
Active filters

Sn (kVA)

P (kW) Gh (kVA) Qc (kVAR)

Sn: apparent power of the transformer.


Gh: apparent power of harmonics-generating
receivers (variable speed motors, static converters,
power electronics, etc.).
Qc: power of the compensation equipment.
V: network voltage.

2 3
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
VarSet Offer Offer Overview VarSet Offer Offer Overview
Key Features

Standard Standard Detuned Key Features


VLVAW2N VLVAW3N VLVAF4P/VLVFF4P b Auxiliary transformer (120 V) included
Lugs 125 to 250 kVAR
480 V 60 Hz 25 to 100 kVAR 75 to 200 kVAR b Top cable entry and connections
Incoming CB 125 to 300 kVAR
b NEMA 1
Lugs
600 V 60 Hz 25 to 100 kVAR 125 to 250 kVAR 75 to 200 kVAR
Incoming CB
Options
b Incoming circuit breaker protection option with rotary handle
b Plinth accessory for floor mounting
> Included for VLVAF4P and VLVFF4P version
> For VLVAW2N and VLVAW3N versions,
order the following part #s:
for Enclosure VLVAW2N: order part #NSYSPF8100
and part #NSYSPS4100
for Enclosure VLVAW3N: order part #NSYSPF10100
and part #NSYSPS4100
b Communication option
> NRC12 controller + modbus communication module
> Order your reference with addition of suffix C
b Sprinkler proof
> Included in 600 V offer

A Current Transformer Is Required For Automatic Control


In order to have automatic control, a current transformer must be ordered in
addition to the PFC bank.
A current transformer (not included) is necessary to provide accurate
network information to the VarSets controller in order to apply the correct
quantity of kVAR at any given time. It is recommended to choose a Split Core
Current Transformer Model 270R from the following list of options.
Note: CT must be sized to your network and have a secondary rating of 5A.
More details on the CT can be found in document 4210CT9701.

Catalog Number Current Rating *(Amperes)


270R-501 500:5
VLVAW2N
270R-102 1000:5
270R-152 1500:5
270R-202 2000:5
270R-302** 3000:5
VLVAW3N VLVAF4P 270R-402** 4000:5

Note: When selecting a CT be sure to use proper rating factors for ambient
temperature conditions.
* 
Rating Factor 30 C/80 F Ambient Temp. = 1.33
Rating Factor 55 C/131 F Ambient Temp. = 1.0
** Models -302 and -402
Rating Factor 30 C/80 F Ambient Temp. = 1.0
Rating Factor 55 C/131 F Ambient Temp. = 0.75

4 5
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
VarSet Offer Offer Range VarSet Offer Offer Range
480 V/60 Hz 600 V/60 Hz

Low-Polluted Network Low-Polluted Network


Standard Standard
Power Lugs Incoming CB Power Lugs Incoming CB
25 VLVAW2N66025AA VLVAW2N66025AB 25 VLVAW2N76025AA VLVAW2N76025AB
50 VLVAW2N66050AA VLVAW2N66050AB 50 VLVAW2N76050AA VLVAW2N76050AB
75 VLVAW2N66075AA VLVAW2N66075AB 75 VLVAW2N76075AA VLVAW2N76075AB
100 VLVAW2N66100AA VLVAW2N66100AB 100 VLVAW2N76100AA VLVAW2N76100AB
125 VLVAW3N66125AA VLVAW3N66125AB 125 VLVAW3N76125AA VLVAW3N76125AB
150 VLVAW3N66150AA VLVAW3N66150AB 150 VLVAW3N76150AA VLVAW3N76150AB
175 VLVAW3N66175AA VLVAW3N66175AB 175 VLVAW3N76175AA VLVAW3N76175AB
200 VLVAW3N66200AA VLVAW3N66200AB 200 VLVAW3N76200AA VLVAW3N76200AB
225 VLVAW3N66225AA VLVAW3N66225AB 225 VLVAW3N76225AA VLVAW3N76225AB
250 VLVAW3N66250AA VLVAW3N66250AB 250 VLVAW3N76250AA VLVAW3N76250AB
275 VLVAW3N66275AB VLVAW3N66275AB
300 VLVAW3N66300AB VLVAW3N66300AB
Polluted Network With Detuned Reactors
Automatic
Polluted Network With Detuned Reactors Power Lugs Incoming CB
Automatic 75 VLVAF4P76075AA VLVAF4P76075AB
Power Lugs Incoming CB 100 VLVAF4P76100AA VLVAF4P76100AB
75 VLVAF4P66075AA VLVAF4P66075AB 125 VLVAF4P76125AA VLVAF4P76125AB
100 VLVAF4P66100AA VLVAF4P66100AB 150 VLVAF4P76150AA VLVAF4P76150AB
125 VLVAF4P66125AA VLVAF4P66125AB 175 VLVAF4P76175AA VLVAF4P76175AB
150 VLVAF4P66150AA VLVAF4P66150AB 200 VLVAF4P76200AA VLVAF4P76200AB
175 VLVAF4P66175AA VLVAF4P66175AB Fixed
200 VLVAF4P66200AA VLVAF4P66200AB Power Lugs Incoming CB
Fixed 75 VLVFF4P76075AA VLVFF4P76075AB
Power Lugs Incoming CB 100 VLVFF4P76100AA VLVFF4P76100AB
75 VLVFF4P66075AA VLVFF4P66075AB 125 VLVFF4P76125AA VLVFF4P76125AB
100 VLVFF4P66100AA VLVFF4P66100AB 150 VLVFF4P76150AA VLVFF4P76150AB
125 VLVFF4P66125AA VLVFF4P66125AB 175 VLVFF4P76175AA VLVFF4P76175AB
150 VLVFF4P66150AA VLVFF4P66150AB 200 VLVFF4P76200AA VLVFF4P76200AB
175 VLVFF4P66175AA VLVFF4P66175AB
200 VLVFF4P66200AA VLVFF4P66200AB

Note:
Low-Polluted Network = TDDi < 8%, THD(V) < 3%
Polluted Network = TDDi < 20%, THD(V) < 7%

6 7
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
VarSet Offer General Characteristics VarSet Offer Physical and Electrical Steps
480 V and 600 V - 60 Hz

VarSet Type kVAR Min Step Resolution Num Mechanical Num Electrical Sequence Electrical Steps
Environment Steps (CBs) Steps (Resolution)
25 12,5 2x12,5 2 2 1,1,1,1 12,5/25,0
Installation Indoor
Humidity up to 95% 50 12,5 2x12.5 + 1x25 3 4 1.1.2.2 12,5/25,0/37,5/50,0

Maximum altitude 2000 m 75 12,5 1x12,5 + 1x25 + 1x37,5 3 6 1,2,3,3 12,5/25,0/37,5/50,0/62,5/


75,0
Enclosure
100 25 2x25 + 50 3 4 1,1,2,2 25/50/75/100
Degree of protection NEMA 1
125 25 1x25 + 2x50 3 5 1.2.2.2 25/50/75/100/125
Color RAL 7035
150 25 2x25 + 2x50 4 6 1.1.2.2 25/50/75/100/125/150

Standard
Degree of mechanical IK10
resistance 175 25 1x25 + 3x50 4 7 1,2,2,2 25/50/75/100/125/150/175
Steps 200 25 2x25 + 3x50 5 5 1,1,2,2,2 25/50/75/100/125/150/
175/200
Step protection With circuit breaker
225 25 1x25 + 4x50 5 9 1.2.2.2 25/50/75/100/125/150/175/
Electrical Characteristics 200/225
Connection type Three-phase 250 50 5x50 5 5 1,1,1,1 50/100/150/200/250
Power losses < 2.5 W/kVAR without detuned reactors 275 25 1x25 + 5x50 6 11 1,2,2,2 25/50/75/100/125/150/175/
< 6 W/kVAR with detuned reactors 200/225/250/275
300 50 6x50 6 6 1.1.1.1 50/100/150/200/250/300
Tuning order 4.2 p.u. (60 Hz ref)
(VarSet Detuned) 75 25 1x25 + 1x50 2 3 1,2,2,2 25/50/75
Maximum permissible 1.1 x Un, 8 h every 24 h 100 25 2x25 + 1x50 3 4 1,1,2,2 25/50/75/100
over voltage

Detuned
125 25 1x25 + 2x50 3 5 1.2.2.2 25/50/75/100/125
Standards
150 25 2x25 + 2x50 4 6 1,1,2,2 25/50/75/100/125/150
> CSA 22.2 No. 190
> UL810, UL508a 175 25 1x25 + 3x50 4 7 1.2.2.2 25/50/75/100/125/150/175

Incoming Connection With Incoming CB With Lugs 200 50 4x50 4 4 1,1,1,1 50/100/150/200
Short Circuit Rating
From 25 to 100 65 kA (480 V) 25 kA
kVAR/no reactors 50 kA (600 V)
From 125 to 300 65 kA (480 V) 25 kA
kVAR/no reactors 50 kA (600 V)
With reactors 65 kA (480 V) 25 kA
50 kA (600 V)

8 9
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
VarSet Offer VarSet Components VarSet Offer VarSet Components
major components are
Square D by Schneider Electric components

Step Circuit Breaker


Our VarSet offer comes with the assurance that the major Each physical step is protected by a step circuit breaker that ensures that
components inside are manufactured by Square D by our equipment is highly fault-tolerant, ensuring continuity of service even
Schneider Electric, thus ensuring high quality. when one or more capacitors are malfunctioning. This superior protection
provides a stage overload protection that cannot be achieved with HRC
fuses, furthermore it eliminates the need for spare fuses. The details of the
steps are on page 9.
VarPlusCan: Heavy Duty Capacitors
The VarSet range of equipment is integrated with heavy-duty aluminum
can capacitors (VarPlusCan) that are specially designed and engineered
Incoming Circuit Breaker
Circuit breakers Square D by Schneider Electric circuit breakers are designed to ensure
to deliver reactive power continuously with low losses.
maximum continuity of service. Our VarSet range of products has the option
Features:
of being protected with an incoming circuit breaker. Our range comes with
p continuous service
an option to integrate circuit breakers of 65 kA breaking capacity for 480 V
p high overload capabilities with good thermal and mechanical properties networks and 50 kA for 600 V networks. Rotary handle is also provided to
p self-healing with discharge resistors facilitate the disconnection of circuit breakers before opening the door. This
VarPlusCan capacitors p pressure-sensitive disconnector on all three phases is an additional protection mechanism to ensure personnel safety.
p special film resistivity and metallization profile for higher thermal efficiency
and enhanced life expectancy Varlogic N Power Factor Controller
Our range of Varlogic N series of Power Factor Controllers are simple to
program, reliable, and intelligent. Varlogic Controllers offer user-friendly
TeSys Contactors Varlogic NR6 features such as a large backlit display, intuitive menus, ergonomic layout of
Capacitor control is accompanied by a transient state resulting from the buttons, direct display of main measurements, and intelligent self set-up.
capacitor load. This generates a very high overcurrent, equivalent to a short The Varlogic N Controllers constantly measure the reactive power of the
circuit of short duration. installation, and control the connection and disconnection of capacitor steps,
Unique technology contactors to obtain the required power factor. The range is composed of:
The contactors used in our devices are specifically designed for capacitor p NR12: control up to 12 capacitor steps
control. They are fitted with a contact block allowing the current to pass on p NRC12 with modbus: control up to 12 capacitor steps, with advanced
closing through damping resistors that limit the current on energization. diagnostic functions and integrated modbus interface communication
Personal safety module, which enables Varlogic functions to be connected to the energy
TeSys LC1D range of contactors
TM
The contactors cannot be operated manually. The contactors are fitted with server EGX300. The EGX300 is an integrated gateway-server that requires
covers to protect them from direct contact. only a Web browser and Ethernet network to log and display real-time data
Varlogic NRC12 and trend plots.
Safety of installations
Damping resistors are used to reduce transient over-voltage.
Auxiliary Transformer
Continuing service life
Auxiliary units, such as contactors, controllers, and fans, operate only on
These contactors are a ready-to-use solution that avoids the installation
120 Volts AC. The voltage for the auxiliaries has to be converted by an
of inrush reactors. Their service life is far longer than that of conventional
auxiliary transformer. In order to simplify the installation process, VarSet
solutions.
equipment comes with an integrated auxiliary transformer.

Detuned Reactors Other Accessories


Detuned reactors enable the protection of capacitors against harmonics. Accessories, such as plinth (for easier installation on uneven surfaces,) can
They are recommended for usage in harmonic-rich networks, and come with be ordered as an option along with the VarSet equipment.
Detuned reactors 4.2 p.u. tuning order.
They are equipped with a thermal protection device for step disconnection.

Spatial Enclosures
p NEMA 1
p IK10: Maximum possible protection against mechanical shocks and can
withstand 20 joules of energy.

Spatial enclosures

10 11
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
VarSet Offer Dimensions and Weights VarSet Offer Dimensions and Weights

VLVAW2N Dimensions (mm/inch) and Maximum Weight (kg/pounds)


VLVAW2N VLVAW3N VLVAF4P/VLVFF4P
H 850/33.5 1200/47.2 1200/47.2
1
1
W 800/31.5 1000/39.4 1300/51.2
W 1 2 D 400/15.7 400/15.7 400/15.7
D1 1200/47.2 1400/55.1 1200/47.2
Weight 80/175 125/275 265/585
61 Does not include plinth for VLVAW2N and VLVAW3N, optional, which adds 100 mm to height.
H 61
2 12
2 Standard Standard Detuned
VLVAW2N VLVAW2N VLVAF4P/VLVFF4P

D Lugs 125 to 250 kVAR


D1 480 V 60 Hz 25 to 100 kVAR 75 to 200 kVAR
Incoming CB 125 to 300 kVAR
Lugs
600 V 60 Hz 25 to 100 kVAR 125 to 250 kVAR 75 to 200 kVAR
Incoming CB

VLVAW3N

W
W 1

H
H

2
D D1
D

VLVAF4P and VLVFF4P

D D1

12 13
Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com
US

7600BR1401R11/14
Schneider Electric

Salisbury, NC 28146
105 Summit Park Dr.

www.schneider-electric.com/us
1-888-SquareD (1-888-778-2733)
Schneider Electric Industries SAS

Courtesy of Steven Engineering, Inc. - (800) 258-9200 - sales@steveneng.com - www.stevenengineering.com


November 2014
2014 Schneider Electric. All Rights Reserved. Schneider Electric, Square D, VarSet, Accusine, TeSys, and Varlogic are trademarks owned by Schneider Electric Industries SAS or its affiliated companies.
All other trademarks are the property of their respective owners. www.schneider-electric.com 9998-1252523_US