Sei sulla pagina 1di 2

V1.

Reader Appearance Menu List Other Setup


80mm 40mm
Press [M] key to enter system management menu. Verify Mode: M[User][OK][Verify Mode][OK][OK]Input employee ID[OK] WorkCode: M [Setup][OK][System][OK][WorkCode Scope][OK]
Use [ /IN]/[OUT/ ] to select ANY/RF+FP/PW+FP/RF+PW/ID+FP[OK][OK]. Input Max[OK]Input Min[OK] [C][OK].
(This requires the administrator authorization if there is admin
Item Explanation Item Explanation
IN IN registered in the system.) Menu List:
14:03 14:03 09
0-999999 Valid scope for the Workcode
Any Fingerprint only, Card only or ID+Password only
09
10-29-09 THU 10-29-09 THU
Restart
Button Dev ID
It requires both Card and Fingerprint Factory default Max 999999
Time RF+FP
verification together setting Min 0
180mm Language Mode It requires both Password and Fingerprint verification Tips: WorkCode indicates the work typeeasily distinguishes which attendance record
Enroll PW+FP
Workcode Scope together is related to which work type.
IP Address
Delete It requires both Card and Password verification
Daylight Saving RF+PW
Verify Mode
Subnet Mask together Net: M [Setup][OK][System][OK][Net][OK]to select [Mode/IP Address/Subnet Mask
User Net /MAC Address/Gateway IP/Server IP/Server Port][OK]Modify parameters[C][OK].
Group Setup MAC Address ID+FP Enter the user ID first then verify the fingerprint
Anti-Back Item Explanation Factory default
Admin Setup Gateway IP Factory default setting
Precision Any TCP/IP Server mode: Common network mode
Admin Clear Server IP setting
Fingerprint Access control Card Access control Side View Volume Mode TCP/IP Client mode: Only communicate Server Mode
Front View Front View Server Port with the PC which has static IP
Unlock Group Setup: M[User][OK][Group Setup][OK][OK] Set terminal IP address when communication
System Input employee ID[OK]Input the group ID[OK][OK].
Door Alert IP Address of TCP/IP, IP address must be a static 192.168.0.218
Item Explanation IP address.
Auto Off
Subnet Mask Subnet Mask of the LAN 255.255.255.0
Setup Auto Update
G00 The user in Group00 can not open the door
Image Disp.
Unique Physical address of the network moudle. This
MAC Address
setting can not be modified.
G01 The user in Group01 can open the door anytime
Log Alert Gateway IP Default Gateway of the LAN 192.168.0.1
Cancel/Power Key
Log Setup It is according to the Group & Time zone setting which
Menu Key Re-Verify G02-16 The IP address of the Sever Machine
Enter System Management Menu Exit/Cancel the Present Operation can be set through the software when using Client Mode TCP/IP 192.168.0.7
Power on/Power off Server IP
Workcode Setup Key Factory default communication.
State Key(Clock In)/Up Hardware Test Keypad, LCD, Sensor, Flash G01
Door Bell Key setting
State Key(Clock Out)/Down
Server Port Its the Software Port number used when the
Num. Keys Tips: Group setup is used for managing the access control privileges. Each group can read is configured for TCP/IP communication. 5010
0-9 Confirm Key System Info User, FP, Log, Serial,FirmVer
Enter Employee ID or Password Confirm Present Operation contain 4 time zones.
Unlock: M [Setup][OK][System][OK][Unlock][OK]No/1~15[OK]
Dev ID: M[Setup][OK][System][OK][Dev ID][OK]
[C][OK]. No-no delay time; The maximum delay time is 15 seconds.
Operation Guide Input the devices ID[OK][C][OK].

Explanation Item Explanation


Item
1 Enroll User: Each user can register two fingerprints, one password and one RFID card. Device ID of the unit which is required in software 1-15
The duration of the audible alarm to notify employees
1-99999999 of events. (Lunch, break, Off Duty)
communication
Factory default No The device does not generate a door open signal after
IN MENU User Enroll
1 successful verification.
setting
09 : 00 26
[M]
User
[OK]
Enroll
[OK] Factory default
Setup Delete ID 008101 Tips: It doesnt allow duplicate Device ID in one LAN. Otherwise, it will cause software
setting 5
10-11-17 WED USB Flash Verify Mode Esc-C Set-OK (ID000001-999999 communication error.
Select [User] Select [Enroll] Input user ID Door Alert: M [Setup][OK][System][OK][Door Alert][OK]
Language: M[Setup][OK][System][OK][Language][OK] to select No/1~99[OK][C][OK]. No-no alert signal.
Use [ /IN]/[OUT/ ] to select ENG/FRCH/GERM/...[OK][C][OK].
Enroll Fingerprint: Place the same finger on the sensor twice in a row to enroll fingerprints. Item Explanation
Enroll FP
Item Explanation
Enroll Enroll FP Enroll FP Enroll FP Enroll FP Enroll FP It generates the door open alarm signal if the door open
FP 1/2 1-250 time is longer than the preset value
press [OK] [OK]
Languages
Password/Card Place Finger #1 Take Off! Place Finger #2 Take Off! 008101-1 Optional 4 languages.
Esc-C Set-OK Cancel-C Sav-OK No Disable the door open alarm
Select [FP] Enroll fingerprint Press [OK] to save Factory default Factory default
setting Related Language 15
Enroll Password: Password length: 000000-999999. setting

Enroll Enroll PWD Enroll PWD Enroll PWD


FP 1/2
Illustration for placing fingerprint
press [OK] [OK] [OK] PWDID ****** [OK]
Password /Card PWDID ****** 008101-P
Esc-C Set-OK Esc-C Set-OK Confm ****** Cancel-C Sav-OK

Select [Password] Input password Input password again Press [OK] to save
Enroll Card
Enroll Enroll Card Enroll Card
Enroll Card
FP 1/2
press [OK] Password/ Card [OK] Swipe card! 008101-C
Esc-C Set-OK Cancel-C Sav-OK

Select [Card] Swipe the card Press [OK] to save

2 Admin Setup: Admin(Administrator) has full access permissions to the device. It is recommended to assign a minimum of Place finger straight and
two administrators to each unit. flat on the sensor. Insure
MENU User Admin Setup Admin Setup Admin Setup Admin Setup maximum sensor coverage.
User Group Setup ID 008101
[OK] [OK] [OK] [OK] [OK]
Setup Admin Setup ID 000000 008101
USB Flash Admin Clear Esc-C Add-OK No-C Yes-OK Esc-C Add-OK
Place finger in the center of the sensor. Place finger on the sensor surface
Select [User] Selelct [Admin Setup] Input Admin ID Setup successful
V1.4

Package List Access Control Reader & Access Control Power Supply

1 Reader 2 Instruction Package Accessory Package Connector Jack


IN IN

WO0 WO1 GND R4A R4B GND DB2 DB1


14:03 14:03

+12

12I
09 09
10-29-09 THU 10-29-09 THU

or Access control

D/S GND
Exit Button

GND PUSH NO
FOR windows
EN C H ...
COMPACT
Windows 98
Windows 2000
CD-ROM
Windows XP
Windows Vista
Windows 7
C
ar

Access Control Power Supply


d

COM NO GND D/M


+
Door Sensor

Installation Diagram Door Bell

GND
Power on to unlock

NC
Installation Step

+
2 1

NC
Power off to unlock

1 Drill holes in the wall follow the hole position on back panel
2 Install and fix back panel, connect related cables
Access Control Reader & Switching Power Supply
3 Connect back panel to front panel by flat cable
3 4 Attach access control reader

Wiring Instruction Switch Power Supply

+12V GND

WO0 WO1 GND R4A R4B GND DB2 DB1


12I
D/S GND
Exit Button

P1 PIN Mark Description

Wiegand 0 Output

COM NO GND D/M


1 WO0
WO0 WO1 GND R4A R4B GND DB2 DB1

2 WO1 Wiegand 1 Output Door Sensor


Power on to unlock
3 GND GND Door Bell
4 R4A RS485A
TCP/IP 5 R4B RS485B
Communication Port 6 GND GND

NC
7 DB2 Door Bell 2
8 DB1 Door Bell 1 Power off to unlock

Access Control Reader & SC011


P2 PIN Mark Description

1 12I DC 12V Input


12I

GND GND Connection Cable


D/S GND

2
3 D/S Door Switch Connect the front part of device
GND D/M

4 D/M Door Monitor

5 GND GND

WO0 WO1 GND R4A R4B GND DB2 DB1


Switch Power Supply

12I
COM NO

6 NO NO

D/S GND
+12V GND
I II III ON OFF
RELAY DELAY PROGRAM
PROGRAM MODE - (YELLOW)
COM
12V-I
7

POWER
SUPPLY LOCK
12V-O
COM NORMAL MODE - (BLUE)

ANVIZ DEVICE
GND GND
NC

8 NC NC GND D0

COM NO GND D/M


NC D1

RELAY OUT
NO GND

BUTTON
EXIT
COM BUT

Power off to unlock

NC
Exit Button
Important notice: Please follow the wiring diagram as it is displayed. Damaged products due to Power on to unlock

improper wiring are not covered by product warranty.

The products are subject to change without notice.

Potrebbero piacerti anche