TRX Configuration Check SOP Guideline V1.00
Name
Version V1.00 Effective Date 2010-07-31
Document
L1
Code Based eTOM

Prepared By L2
Based eTOM

Reviewed By L3
Based eTOM

Approved By L4
Based eTOM
Standard
Applicability Global Analysis engineer
Roles

Relevant Process/Regulation
Document Name Document Code

2017-11-22 Huawei Confidential Page 1 of 12


TRX Configuration Check Confidentiality:

Contents

Relevant Process/Regulation..............................................................1
1 Abstract.............................................................................3
2 Purpose..............................................................................3
Operating Instructions....................................................................4
2.1 TRU:.............................................................................4
2.1.1 Power Type:..................................................................4
2.1.2 Send/Receive Mode............................................................6
2.2 GRFU............................................................................10
2.2.1 Power Type/Send Receive Mode................................................10
2.3 DRFU............................................................................11
2.3.1 Power Type/Send Receive Mode................................................11
2.4 TCH Rate Adjust Allow Audit...................................................13
3 Appendix............................................................................15
4 Support Document(s)..................................................................15
5 Related Document(s)..................................................................15
6 Record Retention.....................................................................15

7 Document Preparation/Modification Record.............................................15

2017-11-22 Huawei Confidential Page 2 of 12


TRX Configuration Check Confidentiality:

1 Abstract

This document instructs engineers how to perform the Base Band Hopping audit.

2 Purpose

This document aims to standardize the operation procedure of the TRX configuration check from the following point

1- TRU
a. Power Type
b. Send/Receive Mode

2- GRFU
a. Power Type/ Send/Receive Mode

3- DRFU
a. Power Type/ Send/Receive Mode

4- TCH Rate Adjust Allow Audit (ALL TYPES OF TRXS)

2017-11-22 Huawei Confidential Page 3 of 12


TRX Configuration Check Confidentiality:

Operating Instructions

2.1 TRU:

2.1.1 Power Type:

1. The Power Setting for the TRU is 60 W


2. To get the Current Power:
Select the TRX and View Site Board
From the Device Attribute Check the Power Type

2017-11-22 Huawei Confidential Page 4 of 12


TRX Configuration Check Confidentiality:

2017-11-22 Huawei Confidential Page 5 of 12


TRX Configuration Check Confidentiality:

2.1.2 Send/Receive Mode

1- The send/Receive Configuration for the TRU depends on the Actual Configuration in the site
2- The main Check for the RF part is that the send/receive mode is correct according to the Number of
TRXs connected to the DDPU which is as following:
No. of TRX Receive
Type TRXs Configuration Send Mode Mode Comment
Dividing
TRX 1 No Combining Receiver TRX1/TRX2 share the same
Dividing HW Board or Separate
DDPU 2 TRX 2 No Combining Receiver Boards
Wide Band Dividing
TRX1 Combining Receiver
Wide Band Dividing TRX1/TRX2 share the same
TRX2 Combining Receiver HW Board
Dividing TRX3 is in Separate HW
DDPU 3 TRX3 No Combining Receiver Board
Wide Band Dividing
TRX1 Combining Receiver
Wide Band Dividing TRX1/TRX2 share the same
TRX2 Combining Receiver HW Board
Wide Band Dividing
TRX3 Combining Receiver
Wide Band Dividing TRX3/TRX4 share the same
DDPU 4 TRX 4 Combining Receiver HW Board

3- To get the No. of TRXs connected to the DDPU do the below steps
Note: this must be done form the Web LMT
1- Select the Cell and Expand the TRXs
2- Select the DDPU ( must be done for all the DDPUs) and select View Site Board
3- From the Antenna Feeder Attribute check the TRX Board No. to know which TRX Connected to
this DDPU
4- After you know the TRXs Repeat the Steps used for the Power Audit to get the Send/Receive
Mode for each one
5- The below Example we have:
a. TRX0/TRX1 share the same HW board and connected to the first DDPU
b. TRX2: different HW board and also connected to the same DDPU
c. Configuration:
i. TRX0/TRX1: Send Mode Wide band Combining

2017-11-22 Huawei Confidential Page 6 of 12


TRX Configuration Check Confidentiality:

ii. TRX2: No Combining

2017-11-22 Huawei Confidential Page 7 of 12


TRX Configuration Check Confidentiality:

2017-11-22 Huawei Confidential Page 8 of 12


TRX Configuration Check Confidentiality:

2017-11-22 Huawei Confidential Page 9 of 12


TRX Configuration Check Confidentiality:

2.2 GRFU

2.2.1 Power Type/Send Receive Mode

1- Two modes for power configuration (Static and Dynamic)

This should depend on the Multi-Density TRX Power Sharing parameter in the channel
management and that it should not be used (Parameter Multi-Density TRX Power Sharing should =
none)

No of TRXs Per GRFU Static TOC Power Dynamic TOC Power


1 60 W 60 W
2 40 W 40 W
3 27 W 31 W
4 20 W 27 W
5 12 W 20 W
6 10 W 16 W

2- To get the No. of TRXs Configured in Each GRFU do the below steps
1. Select the Required Site
2. Click One Click on the GRFU to see the Configured TRXs on it
1. We have here UPP1220P7-1 with TRXs (0,1,2,3,16,17)
2. TRXs (0,1,2,3) Connected to the GRFU_Cabinet 1_Subrack 4_Slot 0
3. The Power Setting for these 4 TRXs will Depend on the Dynamic Power Feature:
1. Multi-Density TRX Power Sharing=Yes Power 27 W
2. Multi-Density TRX Power Sharing=None Power 20 W
4. Check the Power of the TRXs in the same way of the TRU

2017-11-22 Huawei Confidential Page 10 of 12


TRX Configuration Check Confidentiality:

2.3 DRFU

2.3.1 Power Type/Send Receive Mode

1- The Power Configuration Depends on the following:


Frequency Band of the TRX (GSM/DCS)
Site Configuration (Single Feeder/Double Feeder)
No. of TRXs configured in the DRFU
TRX Connection Configuration (TX/RX)
For GSM:

No. GSM
Of Single Feeder Double Feeder
TRX Power/Se
s nd Mode 1TX+1RX 1TX+2RX 1TX+1RX 1TX+2RX 2TX+2RX 2TX+4RX
Power 45W 45W 45W 45W 45W 45W

1 (transmit (transmit (transmit (transmit (transmit (transmit


TRX Send independen independen independen independen independen independen
used Mode t) t) t) t) t) t)
Power 20W 20W 20W 20W 45W 45W

2 (transmit (transmit
TRX Send (transmit (transmit (transmit (transmit independen independen
used Mode combining) combining) combining) combining) t) t)

For DCS:

No. DCS
Of Single Feeder Double Feeder
TRX Power/Se
s nd Mode 1TX+1RX 1TX+2RX 1TX+1RX 1TX+2RX 2TX+2RX 2TX+4RX
Power 40W 40W 40W 40W 40W 40W

1 (transmit (transmit (transmit (transmit (transmit (transmit


TRX Send independen independen independen independen independen independen
used Mode t) t) t) t) t) t)
Power 18W 18W 18W 18W 40W 40W

2 (transmit (transmit
TRX Send (transmit (transmit (transmit (transmit independen independen
used Mode combining) combining) combining) combining) t) t)

2017-11-22 Huawei Confidential Page 11 of 12


TRX Configuration Check Confidentiality:

2- To get the No. of TRXs in the DRFU and the Configuration please do the below steps
Select the Site
Select each DRFU and do the below steps
Right click on the DRFU and choose View Site Board
From the Site Board Attribute check the DRFU Sending Receiving Mode
Check the Power of the TRXs in the same way of the TRU

2017-11-22 Huawei Confidential Page 12 of 12