Sei sulla pagina 1di 11

FIELD Quality plan

Sewage Treatment Plants at Doddabele,Yellamalappachetty


QP.No-1
KEC-WATERLEAU (JV) REV.no-0
and Intermediate Sewage pumping Station and Pumping Mains at Sadarmangala

BOUGHT OUT ITEM - CEMENT REGISTER


Package:
Agency:

RECIVED CUMMULATIVE
DATE OF MAKE/ INVOICE WEEK
S.N. ITEM / DESCRIPTION INVOICE NO. QUANTITY TOTAL TC DETAILS REMARKS
RECEIVING BRAND DATE NO.
(MT) QUANITITY (MT)

1 OP Cement

10

11

12

13

14

15
BOUGHT OUT ITEM - REINFORCEMENT STEEL REGISTER
Package:
Agency:

DATE OF MAKE/ INVOICE RECIEVED QUANTITY


S.N. INVOICE NO. TC DETAILS
RECEIVING BRAND DATE 8mm 10mm 12mm 16mm 20mm 25mm 32mm TOTAL

QUANTITY
RECEIVED IN
CURRENT
PERIOD
QUANTITY
RECEIVED
UPTO DATE
REMARKS
BOUGHT OUT ITEMS (BOIS) REGISTER
Package:
Agency:

1 Item/ Description
BOQ/BBU Item No.:

DATE OF MAKE/ INVOICE RECIVED USED AT LOCATION /


S.N. INVOICE NO. TC DETAILS CUMMULATIVE QTY ITEM
QTY USED QTY BALANCE REMARKS AGENCY NTPC
RECEIVING BRAND DATE QTY
1
2
3
4

2 Item/ Description
BOQ/BBU Item No.:

DATE OF MAKE/ INVOICE RECIVED USED AT LOCATION /


S.N. INVOICE NO. TC DETAILS CUMMULATIVE QTY QTY USED QTY BALANCE REMARKS AGENCY NTPC
RECEIVING BRAND DATE QTY ITEM
1
2
3
4

3 Item/ Description
BOQ/BBU Item No.:

DATE OF MAKE/ INVOICE RECIVED USED AT LOCATION /


S.N. INVOICE NO. TC DETAILS CUMMULATIVE QTY ITEM
QTY USED QTY BALANCE REMARKS AGENCY NTPC
RECEIVING BRAND DATE QTY
1
2
3
4

4 Item/ Description
BOQ/BBU Item No.:

DATE OF MAKE/ INVOICE RECIVED USED AT LOCATION /


S.N. INVOICE NO. TC DETAILS CUMMULATIVE QTY ITEM
QTY USED QTY BALANCE REMARKS AGENCY NTPC
RECEIVING BRAND DATE QTY
1
2
3
4

Note: Each Item (Items other than Cement & Reinforcement steel ) on separate page
CEMENT CONSUMPTION REGISTER (STORES/BATCHING PLANT)

Package:
Agency:
UNIT: NOS.(BAGS)

Consumption Grade of Consum Theoritical Actual


New Qty Opening Concrete Cumulative Closing
Date Area / Concret ption Consumpti Consumpti Agency Sign NTPC Sign
Received Balance Qty(m3) Consumption Balance
Location e Factor on on
CONCETE BATCH REGISTER

Package:
Agency:

Ingredients
Grade of
S.No. Area/ Location Qty (m3) Cement 20mm 10mm Water Admixture Agency Sign NTPC Sign
Concrete Sand (Kg) W/C Ratio
(Kg) Agg (Kg) Agg (kg) (Kg) (Kg)
NTPC SOLAPUR
SOLAPUR SUPER THERMAL POWER PROJECT

CONCRETE POUR CARD

Client:
Package:
Agency:
LOA No. & Date:

Date:

S.NO. DESCRIPTION OBSERVATIONS


1 Area:
2 Reference Drawing No.:
3 Location:
4 Type/Block No.:
5 Item:
6 Reinforcement:
Type Dia Length Nos
Main bars:
Secondary bars:
Side Bars:
Distribution bars:
Extra bars:
Stirrups:
Chairs & Spacers:
7 Inserts:
8 Shuttering:
9 Level/Alignment:
10 Concrete: Grade:
Quantity:

Slump:
11 Clearance for Concreting:
Agency NTPC
12 Concreting: Start:
Completion:
13 Shifts: From To Slump (mm) Agency NTPC
A
B
C
D
14 Reference Cube No.:
15 Shuttering Stripping Time after Concreting (Hours):
16 Level/ Alignment after Concreting:
17 Remarks:

AGENCY
Client:
Contractor:
Name of the Package :
LOA No. & Date:

REQUEST FOR INSPECTION

RFI NO.: DATE:

QUANTITY
S.NO. ITEM/ ACTIVITY/ JOB DESCRIPTION/ LOCATION
INVOLVED

REMARKS:

AGENCY
BAR BENDING SCHEDULE

Package:
Agency:

AREA:
LOCATION:

DIA OF
SPACI SHAPE NO OF NO OF NO OF DEDUCTI CUTTING
S.NO. DESCRIPTION BAR A B C D E LENGTH 8 10 12 16 20 25 32
NG OF BAR SETS BARS BENDS ON LENGTH
(mm)
STATUS OF QUALITY CHECKS
Package: Agency: R.A. Bill: Period:
LOA No. & Date:

Required
BOQ/ Tests/
Quantity Quantity Class of No. of
S.No. BOQ/ BBU Item BBU Unit Location FQP S.No. Type of Check/ Test Frequency Checks Remarks
Claimed Certified Check Tests/
Item No. Performed
Checks

Potrebbero piacerti anche