Sei sulla pagina 1di 1

DVR

SUMMARY:
1-UNIT DVR
4-UNIT CCTV CAMERA
DVR

PC

SECURITY SINGLE LINE


02
SCALE: NTS
PC
01 ECE-01
ECE-01 SCALE: 1:50

CELLULINE MARKETING
ALL ELECTRONIC WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE PROVISION OF THE LOWER GROUND FLOOR
LATEST EDITION OF THE PHIL. ELECTRONIC CODE, THE RULES AND REGULATIONS OF THE LOCAL GAISANO MALL GENSAN
ENFORCING AUTHORITIES AND THE REQUIREMENTS OF THE POWER COMPANY.

ALL ELECTRONIC WORKS INCLUDED HEREIN SHALL BE EXECUTED BY ELECTRONIC TECHNICIAN


UNDER THE DIRECT SUPERVISION OF A FULL-TIME LICENSED/PROF. ELECTRONIC AND
COMMUNICATION ENGINEER. WORKS SHALL BE NEATLY PLACED, SECURELY FASTENED AND

Y
IT
PROPERLY FINISHED. THIS DRAWING IS SCHEMATIC REPRESENTATION OF SYSTEM

C
ONLY. TENDERS TO DETAIL COMPLIANT OFFER BASED ON

AO
THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF SERVICE ENTRANCE MANUFACTURER'S SYSTEM AND WIRING METHODS

AV
FOR CONNECTION TO COMMUNICATION SUPPLY. RECOMMENDATION.

D
TO
ALL MATERIALS SHALL BE BRAND NEW AND SHALL CONFORM WITH THE PROVISIONS OF THE WIRING INSTALLATION (CEILING CONCEALED, EMBEDDED,
UNDERWRITERS LABORATORIES INC. IN EVERY CASE WHERE SUCH A STANDARD HAS BEEN EXPOSED OR SURFACED) SHALL BE USED RSC OR EMT, 15mm
ESTABLISHED. .
VE
ALL CONDUITS MUST BE PROTECTED AGAINST DAMAGES BY THE ENTRANCE OF WATER AND WIRING METHODS SHALL BE AS FOLLOWS: A
A. CCTV CABLE - RG-59/6 COAX CABLE
O
FOREIGN MATTERS DURING CONSTRUCTION. ALL ENDS OF CONDUITS SHALL BE PLUGGED TO C
EXCLUDE MOISTURE AND DUST IMMEDIATELY AFTER THE CONDUITS ARE PLACED.
GAISANO LI
CONDUIT SHALL BE PERMANENTLY AND EFFECTIVELY MALL TO
A
UNLESS OTHERWISE SPECIFIED, ALL ELECTRONIC WIRING INSTALLATION SHALL BE USED RSC PIPE. GROUNDED. C
J.
THIS ARRANGEMENT IS LIMITED TO DROP WIRE
ATTACHMENT OF UP TO 5 LINES.
ALL OUTLET BOXES SHALL BE GALVANIZED GA. 16, DEEP-TYPE WITH FACTORY KNOCKOUTS.
PULLBOXES SHALL BE USED WHEN APPLICABLE FOR EASY PULLING OF WIRES AND SHALL BE IN VERANZA
SPAN TO FIXTURE SHALL BE NOT EXCEED 45.7m.
ACCORDANCE WITH THE PHILIPPINE ELECTRONIC CODE REQUIREMENTS.PREFERRED BRAND FOR . MALL
JUNCTION, PULLBOX OR UTILITY SQUARE BOXES SHALL BE FUMACO, AMCU, TIMCO, OR VD
APPROVED EQUAL.
SERVICE SHALL BE SUFFICIENTLY HIGH TO PROVIDE PROPER
BL KCC MALL
DROP WIRE CLEARANCE OVER SIDE, STREETS OR ROADWAYS O
IN COMPLIANCE WITH THE CODES AND REGULATIONS. G
MOUNTING HEIGHTS OF DEVICES SHALL BE: (SUBJECT TO ARCHITECT'S APPROVAL PRIOR TO T IA
INSTALLATION), DATA OUTLET SHALL BE 0.30m ABOVE FINISHED FLOOR TO CENTER OF DEVICE. N
SA
THE PLANS AS DRAWN ARE BASED UPON THE ARCHITECTURAL PLANS AND THE DETAILS AND TO
SHOWN CONDITION AS ACCURATELY AS IT IS POSSIBLE TO INDICATE THEM IN SCALE, THE PLANS
ARE DIAGRAMMATICAL AND DOES NOT NECESSARY SHOW ALL FITTINGS NECESSARY TO FIT TO
THE BUILDING CONDITIONS. THE LOCATIONS OF OUTLETS, APPARATUS AND APPLIANCES SHOWN
ON THE PLANS ARE APPROXIMATE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THEIR 03
PROPER LOCATION IN ORDER TO MAKE THEM FIT WITH THE ARCHITECTURAL DETAILS AND ECE-01 SCALE: NTS
INSTRUCTIONS FROM THE ENGINEER'S REPRESENTATIVE AT THE SITE.

OWNER: SHEET CONTENT: SHEET NO.

NRN TELECOMS AND ALLIED SERVICES DARWIN D. NISPEROS ; IECEP MS. MARY ANN CAGALAWAN
SECURITY LAYOUT PLAN
SECURITY SINGLE LINE RISER DIAGRAM ECE- 01
ELECTRONIC NOTES
314-A NLSA Rd., Lagao, Gen. Santos City PROF. ELECTRONICS & COMM. ENGR. PROJECT / LOCATION:
GENERAL SPECIFICATIONS 01 01
TELECOMS Mobile #s: 09203042133 Tnt; 09258221429 Sun LEGEND/ SYMBOLS/ ABBREVIATIONS
PRC NO : 0472, 2016 PTR NO: 6595691 AS-BUILT ELECTRONIC PLAN OF LOCATION MAP
nisperos_dd@yahoo.com ddnisperos@gmail.com IECEP NO.: 09-09657, 2018 DATE ISSUED: 01/08/16 CELLULINE MARKETING DATE: April 22, 2016

AND ALLIED SERVICES LOWER GROUND FLOOR (BESIDE FOODCOURT), GAISANO MALL, FILE NAME:
Cell-line Ece
Final.dwg

T.I.N. : 169-824-299 ISSUED AT: G.S.C. J. CATOLICO AVE., BRGY. LAGAO, GEN. SANTOS CITY CADD BY: M. T. L.