DESIGN OF STONE MASONRY RETAINING WALL

A Geometry Data :-
Height of Retaining wall from Top ground level to Top (h1) = 0.000 m
Height of Retaining wall from Formation Road Level to Top ground level (h 2) = 1.000 m
Height of foundation from Formation Road Level (h3)or D = 1.000 m
Top head of retaining wall (Bt) = 0.6 m
Bottom width of retaining wall (Bb) = (For Initial section assume approx. 0.6H) 1.600 m
Surcharge load of Max. Vehicle axail load as per IRC6- 2000 [ Class A]= Load vehicle 70.632 KN
distance of Axle load from retaining wall top X 0.45 m
n
= angle bet resultant force and normal to failure plane/friction angle of soil 29

test report
From soil
3
Unit weight of stone masonry wall (s) = 23.000 KN/m
3
Unit weight of soil (so) = 19.000 KN/m

Frictional coefficient = 0.550

WALL TYPE : - W2 Y
bt= 0.6 m

h1= 0.000 m

A2

h2= 1.000 m H=h1+h2+h3= 2.000 m ka =(active earth pressure coefficient)


30/100
1/5

W= 56.488 KN
((A1 x X1) +(A2 x X2) + (A3 x X3) +(A4 x X4))/ An

Pa =1/2 x Pa x h4 = 4.395 KNm

Road Formation Level


A3 h4 = H/3 = 0.667 m
h3= 1.000 0.400 0.6 0.600 m
A1 '
X bb= 1.600 m
1/5 Pa=K p a x so x H = 13.185 KN/m
2
0.320 hv, m
1.632 m Active Soil pressure
Binclined
Y

B Design parameters:-
Total Height of retaining wall H = h1+h2+h3 = 2.000 m
m= 0.225
n= (assume multiple of 0.5) 4
x =1.77Qpm2n2/(H2(m2+n2)3
for m>0.4 or
m n Z = nH
0.28Qpm2n2/(H2(0.16+n2)3 for
PH

m0.4
0.225 0.250 0.500 4.657 2.354
0.225 0.500 1.000 4.761 2.407
0.225 0.750 1.500 4.869 2.445
0.225 1.000 2.000 4.912
P =H 7.207

Surcharge load from vehicle


1 2 3 4 5 6 7 8 9 10 11 12 13 14
4.950
4.900
4.850
4.800
x

4.750
4.700
4.650
4.600
4.550
4.500
Base length of triange A1 = 0.400 m
Base length of triange A3 = 0.600 m
Base length of triange A4 = 0.064 m
Distance of CG of A1 from X = X1 0.267 m
Distance of CG of A2 from X = X2 0.700 m
Distance of CG of A3 from X = X1 1.200 m
Distance of CG of A4 from X = X4 1.067 m
2
Cross section of Stone masonry retaining wall (A1) = 0.400 m
2
Cross section of Stone masonry retaining wall (A2) = 1.200 m
2
Cross section of Stone masonry retaining wall (A3) = 0.600 m
2
Cross section of Stone masonry retaining wall (A4) = 0.256 m
2
Cross section of Stone masonry retaining wall (An) = 2.456 m
Weight of Stone masonry retaining wall (W) = 56.488 KN
height of line of action for lateral earth pressure (h4) = 0.667 m
1 Sin
Active earth pressure coeff. at base of wall (K p a ) = 0.347
1 Sin
A1 X1 A2 X 2 A3 X 3 A4 X 4
An
distance of W from X = 0.790 m

Vehicle load surcharge Intensity PH=(z-1+z)/2 x Z diff 7.207 KN

dist. of surcharge load from X=d = 0.59H for m 0.4 & 0.48H for m>0.4 1.180 m
Active earth pressure at base of wall Pa = K pa x so x H 13.185 KN/m
Moment due to surcharge Load @ X = PH x d Overturning Moment 8.504 KNm
Moment due to selfweight of wall @ X = W x X Resisting Moment 44.614 KNm
Moment due to active earth pressure @ X =1/2 x Pa x h4 Overturning Moment 4.395 KNm

C Check against overturning:- For FOS = 1.5

Sum of resisting moment = Mres 44.614 KNm

Sum of Overturning moment = Myy over 12.899 KNm

Factor of safety against Overturning (FOS overturning) = 3.459 OK

D Check againstg Sliding:- For FOS = 1.5


Frictional coefficient = 0.550
Resisting force against sliding (W) = 31.068 KN

Sum of Sliding Forces ( Surcharge Load + Active earth pressure) = 20.392 KN

Factor of safety against Sliding (FOS sliding) = 31.068 / 20.392 1.524 OK


DESIGN OF STONE MASONRY RETAINING WALL

A Geometry Data :-
Height of Retaining wall from Top ground level to Top (h1) = 0.000 m
Height of Retaining wall from Formation Road Level to Top ground level (h 2) = 1.500 m
Height of foundation from Formation Road Level (h3)or D = 1.000 m
Top head of retaining wall (Bt) = 0.6 m
Bottom width of retaining wall (Bb) = (For Initial section assume approx. 0.6H) 1.800 m
Surcharge load of Max. Vehicle axail load as per IRC6- 2000 [ Class A]= Load vehicle 70.632 KN
distance of Axle load from retaining wall top X 0.45 m
n
= angle bet resultant force and normal to failure plane/friction angle of soil 29

test report
From soil
3
Unit weight of stone masonry wall (s) = 23.000 KN/m
3
Unit weight of soil (so) = 19.000 KN/m

Frictional coefficient = 0.450

WALL TYPE : - W2 Y
bt= 0.6 m

h1= 0.000 m

A2

h2 = 1.500 m H=h1+h2+h3= 2.500 m ka =(active earth pressure coefficient)


28/100
1/5

W= 76.452 KN
((A1 x X1) +(A2 x X2) + (A3 x X3) +(A4 x X4))/ An

Pa =1/2 x Pa x h4 = 6.867 KNm

Road Formation Level


A3 h4 = H/3 = 0.833 m
h3 = 1.000 0.500 0.6 0.700 m
A1 '
X bb= 1.800 m
1/5 Pa=K p a x so x H = 16.481 KN/m
2
0.360 hv, m
1.836 m Active Soil pressure
Binclined
Y

B Design parameters:-
Total Height of retaining wall H = h1+h2+h3 = 2.500 m
m= 0.180
n= (assume multiple of 0.5) 5
x =1.77Qpm2n2/(H2(m2+n2)3
for m>0.4 or
m n Z = nH
0.28Qpm2n2/(H2(0.16+n2)3 for
PH

m0.4
0.180 0.200 0.500 3.002 1.502
0.180 0.400 1.000 3.006 1.522
0.180 0.600 1.500 3.081 1.551
0.180 0.800 2.000 3.124 1.567
0.180 1.000 2.500 3.144
P =H 6.142

Surcharge load from vehicle


1 2 3 4 5 6 7 8 9 10 11 12 13 14
3.200

3.150

3.100
x

3.050

3.000

2.950

2.900
Base length of triange A1 = 0.500 m
Base length of triange A3 = 0.700 m
Base length of triange A4 = 0.072 m
Distance of CG of A1 from X = X1 0.333 m
Distance of CG of A2 from X = X2 0.800 m
Distance of CG of A3 from X = X1 1.333 m
Distance of CG of A4 from X = X4 1.200 m
2
Cross section of Stone masonry retaining wall (A1) = 0.625 m
2
Cross section of Stone masonry retaining wall (A2) = 1.500 m
2
Cross section of Stone masonry retaining wall (A3) = 0.875 m
2
Cross section of Stone masonry retaining wall (A4) = 0.324 m
2
Cross section of Stone masonry retaining wall (An) = 3.324 m
Weight of Stone masonry retaining wall (W) = 76.452 KN
height of line of action for lateral earth pressure (h4) = 0.833 m
1 Sin
Active earth pressure coeff. at base of wall (K p a ) = 0.347
1 Sin
A1 X1 A2 X 2 A3 X 3 A4 X 4
An
distance of W from X = 0.892 m

Vehicle load surcharge Intensity PH=(z-1+z)/2 x Z diff 6.142 KN

dist. of surcharge load from X=d = 0.59H for m 0.4 & 0.48H for m>0.4 1.475 m
Active earth pressure at base of wall Pa = K pa x so x H 16.481 KN/m
Moment due to surcharge Load @ X = PH x d Overturning Moment 9.060 KNm
Moment due to selfweight of wall @ X = W x X Resisting Moment 68.167 KNm
Moment due to active earth pressure @ X =1/2 x Pa x h4 Overturning Moment 6.867 KNm

C Check against overturning:- For FOS = 1.5

Sum of resisting moment = Mres 68.167 KNm

Sum of Overturning moment = Myy over 15.927 KNm

Factor of safety against Overturning (FOS overturning) = 4.280 OK

D Check againstg Sliding:- For FOS = 1.5


Frictional coefficient = 0.450
Resisting force against sliding (W) = 34.403 KN

Sum of Sliding Forces ( Surcharge Load + Active earth pressure) = 22.623 KN

Factor of safety against Sliding (FOS sliding) = 34.403 / 22.623 1.521 OK


DESIGN OF STONE MASONRY RETAINING WALL

A Geometry Data :-
Height of Retaining wall from Top ground level to Top (h1) = 0.000 m
Height of Retaining wall from Formation Road Level to Top ground level (h 2) = 2.000 m
Height of foundation from Formation Road Level (h3)or D = 1.000 m
Top head of retaining wall (Bt) = 0.6 m
Bottom width of retaining wall (Bb) = (For Initial section assume approx. 0.6H) 1.950 m
Surcharge load of Max. Vehicle axail load as per IRC6- 2000 [ Class A]= Load vehicle 70.632 KN
distance of Axle load from retaining wall top X 0.45 m
n
= angle bet resultant force and normal to failure plane/friction angle of soil 29

test report
From soil
3
Unit weight of stone masonry wall (s) = 23.000 KN/m
3
Unit weight of soil (so) = 19.000 KN/m

Frictional coefficient = 0.450

WALL TYPE : - W2 Y
bt= 0.6 m

h1= 0.000 m

A2

h2= 2.000 m H=h1+h2+h3= 3.000 m ka =(active earth pressure coefficient)


25/100
1/5

W= 96.721 KN
((A1 x X1) +(A2 x X2) + (A3 x X3) +(A4 x X4))/ An

Pa =1/2 x Pa x h4 = 9.889 KNm

Road Formation Level


A3 h4 = H/3 = 1.000 m
h3= 1.000 0.600 0.6 0.750 m
A1 '
X bb= 1.950 m
1/5 Pa=K p a x so x H = 19.778 KN/m
2
0.390 hv, m
1.989 m Active Soil pressure
Binclined
Y

B Design parameters:-
Total Height of retaining wall H = h1+h2+h3 = 3.000 m
m= 0.150
n= (assume multiple of 0.5) 6
x =1.77Qpm2n2/(H2(m2+n2)3
for m>0.4 or
m n Z = nH
0.28Qpm2n2/(H2(0.16+n2)3 for
PH

m0.4
0.150 0.167 0.500 2.103 1.044
0.150 0.333 1.000 2.072 1.047
0.150 0.500 1.500 2.116 1.067
0.150 0.667 2.000 2.152 1.081
0.150 0.833 2.500 2.172 1.089
0.150 1.000 3.000 2.183
P =H 5.328

Surcharge load from vehicle


1 2 3 4 5 6 7 8 9 10 11 12 13 14
2.200
2.180
2.160
2.140
x

2.120
2.100
2.080
2.060
2.040
2.020
2.000
Base length of triange A1 = 0.600 m
Base length of triange A3 = 0.750 m
Base length of triange A4 = 0.078 m
Distance of CG of A1 from X = X1 0.400 m
Distance of CG of A2 from X = X2 0.900 m
Distance of CG of A3 from X = X1 1.450 m
Distance of CG of A4 from X = X4 1.300 m
2
Cross section of Stone masonry retaining wall (A1) = 0.900 m
2
Cross section of Stone masonry retaining wall (A2) = 1.800 m
2
Cross section of Stone masonry retaining wall (A3) = 1.125 m
2
Cross section of Stone masonry retaining wall (A4) = 0.380 m
2
Cross section of Stone masonry retaining wall (An) = 4.205 m
Weight of Stone masonry retaining wall (W) = 96.721 KN
height of line of action for lateral earth pressure (h4) = 1.000 m
1 Sin
Active earth pressure coeff. at base of wall (K p a ) = 0.347
1 Sin
A1 X1 A2 X 2 A3 X 3 A4 X 4
An
distance of W from X = 0.976 m

Vehicle load surcharge Intensity PH=(z-1+z)/2 x Z diff 5.328 KN

dist. of surcharge load from X=d = 0.59H for m 0.4 & 0.48H for m>0.4 1.770 m
Active earth pressure at base of wall Pa = K pa x so x H 19.778 KN/m
Moment due to surcharge Load @ X = PH x d Overturning Moment 9.430 KNm
Moment due to selfweight of wall @ X = W x X Resisting Moment 94.428 KNm
Moment due to active earth pressure @ X =1/2 x Pa x h4 Overturning Moment 9.889 KNm

C Check against overturning:- For FOS = 1.5

Sum of resisting moment = Mres 94.428 KNm

Sum of Overturning moment = Myy over 19.319 KNm

Factor of safety against Overturning (FOS overturning) = 4.888 OK

D Check againstg Sliding:- For FOS = 1.5


Frictional coefficient = 0.450
Resisting force against sliding (W) = 43.524 KN

Sum of Sliding Forces ( Surcharge Load + Active earth pressure) = 25.105 KN

Factor of safety against Sliding (FOS sliding) = 43.524 / 25.105 1.734 OK


DESIGN OF STONE MASONRY RETAINING WALL

A Geometry Data :-
Height of Retaining wall from Top ground level to Top (h1) = 0.000 m
Height of Retaining wall from Formation Road Level to Top ground level (h 2) = 3.000 m
Height of foundation from Formation Road Level (h3)or D = 1.000 m
Top head of retaining wall (Bt) = 0.6 m
Bottom width of retaining wall (Bb) = (For Initial section assume approx. 0.6H) 2.000 m
Surcharge load of Max. Vehicle axail load as per IRC6- 2000 [ Class A]= Load vehicle 70.632 KN
distance of Axle load from retaining wall top X 0.45 m
n
= angle bet resultant force and normal to failure plane/friction angle of soil 29

test report
From soil
3
Unit weight of stone masonry wall (s) = 23.000 KN/m
3
Unit weight of soil (so) = 19.000 KN/m

Frictional coefficient = 0.450

WALL TYPE : - W2 Y
bt= 0.6 m

h1= 0.000 m

A2

h2 = 3.000 m H=h1+h2+h3= 4.000 m ka =(active earth pressure coefficient)


15/100
1/5

W= 128.800 KN
((A1 x X1) +(A2 x X2) + (A3 x X3) +(A4 x X4))/ An

Pa =1/2 x Pa x h4 = 17.580 KNm

Road Formation Level


A3 h4 = H/3 = 1.333 m
h3 = 1.000 0.800 0.6 0.600 m
A1 '
X bb= 2.000 m
1/5 Pa=K p a x so x H = 26.370 KN/m
2
0.400 hv,m
2.04 m Active Soil pressure
Binclined
Y

B Design parameters:-
Total Height of retaining wall H = h1+h2+h3 = 4.000 m
m= 0.113
n= (assume multiple of 0.5) 8
x =1.77Qpm2n2/(H2(m2+n2)3
for m>0.4 or
m n Z = nH
0.28Qpm2n2/(H2(0.16+n2)3 for
P H

m0.4
0.113 0.125 0.500 1.200 0.591
0.113 0.250 1.000 1.164 0.584
0.113 0.375 1.500 1.171 0.590
0.113 0.500 2.000 1.190 0.599
0.113 0.625 2.500 1.206 0.606
0.113 0.750 3.000 1.217 0.610
0.113 0.875 3.500 1.224 0.613
0.113 1.000 4.000 1.228
P =H 4.193

Surcharge load from vehicle


1 2 3 4 5 6 7 8 9 10 11 12 13 14
1.240

1.220

1.200
x

1.180

1.160

1.140

1.120
Base length of triange A1 = 0.800 m
Base length of triange A3 = 0.600 m
Base length of triange A4 = 0.080 m
Distance of CG of A1 from X = X1 0.533 m
Distance of CG of A2 from X = X2 1.100 m
Distance of CG of A3 from X = X1 1.600 m
Distance of CG of A4 from X = X4 1.333 m
2
Cross section of Stone masonry retaining wall (A1) = 1.600 m
2
Cross section of Stone masonry retaining wall (A2) = 2.400 m
2
Cross section of Stone masonry retaining wall (A3) = 1.200 m
2
Cross section of Stone masonry retaining wall (A4) = 0.400 m
2
Cross section of Stone masonry retaining wall (An) = 5.600 m
Weight of Stone masonry retaining wall (W) = 128.800 KN
height of line of action for lateral earth pressure (h4) = 1.333 m
1 Sin
Active earth pressure coeff. at base of wall (K p a ) = 0.347
1 Sin
A1 X1 A2 X 2 A3 X 3 A4 X 4
An
distance of W from X = 1.062 m

Vehicle load surcharge Intensity PH=(z-1+z)/2 x Z diff 4.193 KN

dist. of surcharge load from X=d = 0.59H for m 0.4 & 0.48H for m>0.4 2.360 m
Active earth pressure at base of wall Pa = K pa x so x H 26.370 KN/m
Moment due to surcharge Load @ X = PH x d Overturning Moment 9.896 KNm
Moment due to selfweight of wall @ X = W x X Resisting Moment 136.773 KNm
Moment due to active earth pressure @ X =1/2 x Pa x h4 Overturning Moment 17.580 KNm

C Check against overturning:- For FOS = 1.75

Sum of resisting moment = Mres 136.773 KNm

Sum of Overturning moment = Myy over 27.476 KNm

Factor of safety against Overturning (FOS overturning) = 4.978 OK

D Check againstg Sliding:- For FOS = 1.75


Frictional coefficient = 0.450
Resisting force against sliding (W) = 57.960 KN

Sum of Sliding Forces ( Surcharge Load + Active earth pressure) = 30.563 KN

Factor of safety against Sliding (FOS sliding) = 57.960 / 30.563 1.896 OK


DESIGN OF STONE MASONRY RETAINING WALL

A Geometry Data :-
Height of Retaining wall from Top ground level to Top (h1) = 0.000 m
Height of Retaining wall from Formation Road Level to Top ground level (h 2) = 4.000 m
Height of foundation from Formation Road Level (h3)or D = 1.000 m
Top head of retaining wall (Bt) = 0.6 m
Bottom width of retaining wall (Bb) = (For Initial section assume approx. 0.6H) 2.500 m
Surcharge load of Max. Vehicle axail load as per IRC6- 2000 [ Class A]= Load vehicle 70.632 KN
distance of Axle load from retaining wall top X 0.45 m
n
= angle bet resultant force and normal to failure plane/friction angle of soil 29

test report
From soil
3
Unit weight of stone masonry wall (s) = 23.000 KN/m
3
Unit weight of soil (so) = 19.000 KN/m

Frictional coefficient = 0.450

WALL TYPE : - W2 Y
bt= 0.6 m

h1= 0.000 m

A2

h2= 4.000 m H=h1+h2+h3= 5.000 m ka =(active earth pressure coefficient)


18/100
1/5

W= 192.625 KN
((A1 x X1) +(A2 x X2) + (A3 x X3) +(A4 x X4))/ An

Pa =1/2 x Pa x h4 = 27.469 KNm

Road Formation Level


A3 h4 = H/3 = 1.667 m
h3= 1.000 1.000 0.6 0.900 m
A1 '
X bb= 2.500 m
1/5 Pa=K p a x so x H = 32.963 KN/m
2
0.500 hv, m
2.55 m Active Soil pressure
Binclined
Y

B Design parameters:-
Total Height of retaining wall H = h1+h2+h3 = 5.000 m
m= 0.090
n= (assume multiple of 0.5) 10
x =1.77Qpm2n2/(H2(m2+n2)3
for m>0.4 or
m n Z = nH
0.28Qpm2n2/(H2(0.16+n2)3 for
P H

m0.4
0.090 0.100 0.500 0.775 0.381
0.090 0.200 1.000 0.751 0.374
0.090 0.300 1.500 0.744 0.374
0.090 0.400 2.000 0.752 0.378
0.090 0.500 2.500 0.762 0.383
0.090 0.600 3.000 0.770 0.387
0.090 0.700 3.500 0.777 0.389
0.090 0.800 4.000 0.781 0.391
0.090 0.900 4.500 0.784 0.392
0.090 1.000 5.000 0.786
P =H 3.450

Surcharge load from vehicle


1 2 3 4 5 6 7 8 9 10 11 12 13 14
0.790

0.780

0.770
x

0.760

0.750

0.740

0.730

0.720
Base length of triange A1 = 1.000 m
Base length of triange A3 = 0.900 m
Base length of triange A4 = 0.100 m
Distance of CG of A1 from X = X1 0.667 m
Distance of CG of A2 from X = X2 1.300 m
Distance of CG of A3 from X = X1 1.900 m
Distance of CG of A4 from X = X4 1.667 m
2
Cross section of Stone masonry retaining wall (A1) = 2.500 m
2
Cross section of Stone masonry retaining wall (A2) = 3.000 m
2
Cross section of Stone masonry retaining wall (A3) = 2.250 m
2
Cross section of Stone masonry retaining wall (A4) = 0.625 m
2
Cross section of Stone masonry retaining wall (An) = 8.375 m
Weight of Stone masonry retaining wall (W) = 192.625 KN
height of line of action for lateral earth pressure (h4) = 1.667 m
1 Sin
Active earth pressure coeff. at base of wall (K p a ) = 0.347
1 Sin
A1 X1 A2 X 2 A3 X 3 A4 X 4
An
distance of W from X = 1.300 m

Vehicle load surcharge Intensity PH=(z-1+z)/2 x Z diff 3.450 KN

dist. of surcharge load from X=d = 0.59H for m 0.4 & 0.48H for m>0.4 2.950 m
Active earth pressure at base of wall Pa = K pa x so x H 32.963 KN/m
Moment due to surcharge Load @ X = PH x d Overturning Moment 10.178 KNm
Moment due to selfweight of wall @ X = W x X Resisting Moment 250.317 KNm
Moment due to active earth pressure @ X =1/2 x Pa x h4 Overturning Moment 27.469 KNm

C Check against overturning:- For FOS = 2.0

Sum of resisting moment = Mres 250.317 KNm

Sum of Overturning moment = Myy over 37.647 KNm

Factor of safety against Overturning (FOS overturning) = 6.649 OK

D Check againstg Sliding:- For FOS = 2.0


Frictional coefficient = 0.450
Resisting force against sliding (W) = 86.681 KN

Sum of Sliding Forces ( Surcharge Load + Active earth pressure) = 36.413 KN

Factor of safety against Sliding (FOS sliding) = 86.681 / 36.413 2.381 OK


DESIGN OF STONE MASONRY RETAINING WALL

A Geometry Data :-
Height of Retaining wall from Top ground level to Top (h1) = 0.000 m
Height of Retaining wall from Formation Road Level to Top ground level (h 2) = 5.000 m
Height of foundation from Formation Road Level (h3)or D = 1.000 m
Top head of retaining wall (Bt) = 0.6 m
Bottom width of retaining wall (Bb) = (For Initial section assume approx. 0.6H) 3.000 m
Surcharge load of Max. Vehicle axail load as per IRC6- 2000 [ Class A]= Load vehicle 70.632 KN
distance of Axle load from retaining wall top X 0.45 m
n
= angle bet resultant force and normal to failure plane/friction angle of soil 30

test report
From soil
3
Unit weight of stone masonry wall (s) = 23.000 KN/m
3
Unit weight of soil (so) = 20.000 KN/m

Frictional coefficient = 0.450

WALL TYPE : - W2 Y
bt= 0.6 m

h1= 0.000 m

A2

h2= 5.000 m H=h1+h2+h3= 6.000 m ka =(active earth pressure coefficient)


20/100
1/5

W= 269.100 KN
((A1 x X1) +(A2 x X2) + (A3 x X3) +(A4 x X4))/ An

Pa =1/2 x Pa x h4 = 40.000 KNm

Road Formation Level


A3 h4 = H/3 = 2.000 m
h3= 1.000 1.200 0.6 1.200 m
A1 '
X bb= 3.000 m
1/5 Pa=K p a x so x H = 40.000 KN/m
2
0.600 hv, m
3.059 m Active Soil pressure
Binclined
Y

B Design parameters:-
Total Height of retaining wall H = h1+h2+h3 = 6.000 m
m= 0.075
n= (assume multiple of 0.5) 12
x =1.77Qpm2n2/(H2(m2+n2)3
for m>0.4 or
m n Z = nH
0.28Qpm2n2/(H2(0.16+n2)3 for
P H

m0.4
0.075 0.083 0.500 0.541 0.267
0.075 0.167 1.000 0.526 0.261
0.075 0.250 1.500 0.517 0.259
0.075 0.333 2.000 0.518 0.260
0.075 0.417 2.500 0.523 0.263
0.075 0.500 3.000 0.529 0.266
0.075 0.583 3.500 0.534 0.268
0.075 0.667 4.000 0.538 0.270
0.075 0.750 4.500 0.541 0.271
0.075 0.833 5.000 0.543 0.272
0.075 0.917 5.500 0.545 0.273
0.075 1.000 6.000 0.546
P =H 2.929

Surcharge load from vehicle


1 2 3 4 5 6 7 8 9 10 11 12 13 14
0.550
0.545
0.540
0.535
x

0.530
0.525
0.520
0.515
0.510
0.505
0.500
Base length of triange A1 = 1.200 m
Base length of triange A3 = 1.200 m
Base length of triange A4 = 0.120 m
Distance of CG of A1 from X = X1 0.800 m
Distance of CG of A2 from X = X2 1.500 m
Distance of CG of A3 from X = X1 2.200 m
Distance of CG of A4 from X = X4 2.000 m
2
Cross section of Stone masonry retaining wall (A1) = 3.600 m
2
Cross section of Stone masonry retaining wall (A2) = 3.600 m
2
Cross section of Stone masonry retaining wall (A3) = 3.600 m
2
Cross section of Stone masonry retaining wall (A4) = 0.900 m
2
Cross section of Stone masonry retaining wall (An) = 11.700 m
Weight of Stone masonry retaining wall (W) = 269.100 KN
height of line of action for lateral earth pressure (h4) = 2.000 m
1 Sin
Active earth pressure coeff. at base of wall (K p a ) = 0.333
1 Sin
A1 X1 A2 X 2 A3 X 3 A4 X 4
An
distance of W from X = 1.538 m

Vehicle load surcharge Intensity PH=(z-1+z)/2 x Z diff 2.929 KN

dist. of surcharge load from X=d = 0.59H for m 0.4 & 0.48H for m>0.4 3.540 m
Active earth pressure at base of wall Pa = K pa x so x H 40.000 KN/m
Moment due to surcharge Load @ X = PH x d Overturning Moment 10.368 KNm
Moment due to selfweight of wall @ X = W x X Resisting Moment 414.000 KNm
Moment due to active earth pressure @ X =1/2 x Pa x h4 Overturning Moment 40.000 KNm

C Check against overturning:- For FOS = 2.5

Sum of resisting moment = Mres 414.000 KNm

Sum of Overturning moment = Myy over 50.368 KNm

Factor of safety against Overturning (FOS overturning) = 8.220 OK

D Check againstg Sliding:- For FOS = 2.5


Frictional coefficient = 0.450
Resisting force against sliding (W) = 121.095 KN

Sum of Sliding Forces ( Surcharge Load + Active earth pressure) = 42.929 KN

Factor of safety against Sliding (FOS sliding) = 121.095 / 42.929 2.821 OK


DESIGN OF STONE MASONRY RETAINING WALL

A Geometry Data :-
Height of Retaining wall from Top ground level to Top (h1) = 0.000 m
Height of Retaining wall from Formation Road Level to Top ground level (h 2) = 6.000 m
Height of foundation from Formation Road Level (h3)or D = 1.000 m
Top head of retaining wall (Bt) = 0.6 m
Bottom width of retaining wall (Bb) = (For Initial section assume approx. 0.6H) 3.500 m
Surcharge load of Max. Vehicle axail load as per IRC6- 2000 [ Class A]= Load vehicle 70.632 KN
distance of Axle load from retaining wall top X 0.45 m
n
= angle bet resultant force and normal to failure plane/friction angle of soil 30

test report
From soil
3
Unit weight of stone masonry wall (s) = 23.000 KN/m
3
Unit weight of soil (so) = 20.000 KN/m

Frictional coefficient = 0.450

WALL TYPE : - W2 Y
bt= 0.6 m

h1= 0.000 m

A2

h2 = 6.000 m H=h1+h2+h3= 7.000 m ka =(active earth pressure coefficient)


21/100
1/5

W= 358.225 KN
((A1 x X1) +(A2 x X2) + (A3 x X3) +(A4 x X4))/ An

Pa =1/2 x Pa x h4 = 54.444 KNm

Road Formation Level


A3 h4 = H/3 = 2.333 m
h3 = 1.000 1.400 0.6 1.500 m
A1 '
X bb= 3.500 m
1/5 Pa=K p a x so x H = 46.667 KN/m
2
0.700 hv, m
Binclined 3.569 m Active Soil pressure

B Design parameters:-
Total Height of retaining wall H = h1+h2+h3 = 7.000 m
m= 0.064
n= (assume multiple of 0.5) 14
x =1.77Qpm2n2/(H2(m2+n2)3
for m>0.4 or
m n Z = nH
0.28Qpm2n2/(H2(0.16+n2)3 for
P H

m0.4
0.064 0.071 0.500 0.399 0.197
0.064 0.143 1.000 0.389 0.193
0.064 0.214 1.500 0.382 0.190
0.064 0.286 2.000 0.380 0.190
0.064 0.357 2.500 0.381 0.192
0.064 0.429 3.000 0.385 0.193
0.064 0.500 3.500 0.389 0.195
0.064 0.571 4.000 0.392 0.197
0.064 0.643 4.500 0.395 0.198
0.064 0.714 5.000 0.397 0.199
0.064 0.786 5.500 0.398 0.199
0.064 0.857 6.000 0.399 0.200
0.064 0.929 6.500 0.400 0.200
0.064 1.000 7.000 0.401
P =H 2.543

Surcharge load from vehicle


1 2 3 4 5 6 7 8 9 10 11 12 13 14
0.405
0.400
0.395
0.390
x

0.385
0.380
0.375
0.370
0.365
Base length of triange A1 = 1.400 m
Base length of triange A3 = 1.500 m
Base length of triange A4 = 0.140 m
Distance of CG of A1 from X = X1 0.933 m
Distance of CG of A2 from X = X2 1.700 m
Distance of CG of A3 from X = X1 2.500 m
Distance of CG of A4 from X = X4 2.333 m
2
Cross section of Stone masonry retaining wall (A1) = 4.900 m
2
Cross section of Stone masonry retaining wall (A2) = 4.200 m
2
Cross section of Stone masonry retaining wall (A3) = 5.250 m
2
Cross section of Stone masonry retaining wall (A4) = 1.225 m
2
Cross section of Stone masonry retaining wall (An) = 15.575 m
Weight of Stone masonry retaining wall (W) = 358.225 KN
height of line of action for lateral earth pressure (h4) = 2.333 m
1 Sin
Active earth pressure coeff. at base of wall (K p a ) = 0.333
1 Sin
A1 X1 A2 X 2 A3 X 3 A4 X 4
An
distance of W from X = 1.778 m

Vehicle load surcharge Intensity PH=(z-1+z)/2 x Z diff 2.543 KN

dist. of surcharge load from X=d = 0.59H for m 0.4 & 0.48H for m>0.4 4.130 m
Active earth pressure at base of wall Pa = K pa x so x H 46.667 KN/m
Moment due to surcharge Load @ X = PH x d Overturning Moment 10.504 KNm
Moment due to selfweight of wall @ X = W x X Resisting Moment 637.023 KNm
Moment due to active earth pressure @ X =1/2 x Pa x h4 Overturning Moment 54.444 KNm

C Check against overturning:- For FOS = 2.5

Sum of resisting moment = Mres 637.023 KNm

Sum of Overturning moment = Myy over 64.948 KNm

Factor of safety against Overturning (FOS overturning) = 9.808 OK

D Check againstg Sliding:- For FOS = 2.5


Frictional coefficient = 0.450
Resisting force against sliding (W) = 161.201 KN

Sum of Sliding Forces ( Surcharge Load + Active earth pressure) = 49.210 KN

Factor of safety against Sliding (FOS sliding) = 161.201 / 49.210 3.276 OK


DESIGN OF STONE MASONRY RETAINING WALL

A Geometry Data :-
Height of Retaining wall from Top ground level to Top (h1) = 0.000 m
Height of Retaining wall from Formation Road Level to Top ground level (h 2) = 7.000 m
Height of foundation from Formation Road Level (h3)or D = 1.000 m
Top head of retaining wall (Bt) = 0.6 m
Bottom width of retaining wall (Bb) = (For Initial section assume approx. 0.6H) 4.000 m
Surcharge load of Max. Vehicle axail load as per IRC6- 2000 [ Class A]= Load vehicle 70.632 KN
distance of Axle load from retaining wall top X 0.45 m
= angle betn resultant force and normal to failure plane/friction angle of soil 30

test report
From soil
3
Unit weight of stone masonry wall (s) = 23.000 KN/m
3
Unit weight of soil (so) = 20.000 KN/m

Frictional coefficient = 0.450

WALL TYPE : - W2 Y
bt= 0.6 m

h1= 0.000 m

A2

h2= 7.000 m H=h1+h2+h3= 8.000 m ka =(active earth pressure coefficient)


23/100
1/5

W= 460.000 KN
((A1 x X1) +(A2 x X2) + (A3 x X3) +(A4 x X4))/ An

Pa =1/2 x Pa x h4 = 71.111 KNm

Road Formation Level


A3 h4 = H/3 = 2.667 m
h3= 1.000 1.600 0.6 1.800 m
A1 '
X bb = 4.000 m
1/5 Pa=K p a x so x H = 53.333 KN/m
2
0.800 hv, m
Binclined 4.079 m Active Soil pressure

B Design parameters:-
Total Height of retaining wall H = h1+h2+h3 = 8.000 m
m= 0.056
n= (assume multiple of 0.5) 16
x =1.77Qpm2n2/(H2(m2+n2)3
for m>0.4 or
m n Z = nH
0.28Qpm2n2/(H2(0.16+n2)3 for
P
H

m0.4
0.056 0.063 0.500 0.306 0.152
0.056 0.125 1.000 0.300 0.148
0.056 0.188 1.500 0.294 0.146
0.056 0.250 2.000 0.291 0.146
0.056 0.313 2.500 0.291 0.146
0.056 0.375 3.000 0.293 0.147
0.056 0.438 3.500 0.295 0.148
0.056 0.500 4.000 0.298 0.149
0.056 0.563 4.500 0.300 0.150
0.056 0.625 5.000 0.302 0.151
0.056 0.688 5.500 0.303 0.152
0.056 0.750 6.000 0.304 0.152
0.056 0.813 6.500 0.305 0.153
0.056 0.875 7.000 0.306 0.153
0.056 0.938 7.500 0.307 0.153
0.056 1.000 8.000 0.307
P = H 2.247

Surcharge load from vehicle


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0.310

0.305

0.300
x

0.295

0.290

0.285

0.280
Base length of triange A1 = 1.600 m
Base length of triange A3 = 1.800 m
Base length of triange A4 = 0.160 m
Distance of CG of A1 from X = X1 1.067 m
Distance of CG of A2 from X = X2 1.900 m
Distance of CG of A3 from X = X1 2.800 m
Distance of CG of A4 from X = X4 2.667 m
2
Cross section of Stone masonry retaining wall (A1) = 6.400 m
2
Cross section of Stone masonry retaining wall (A2) = 4.800 m
2
Cross section of Stone masonry retaining wall (A3) = 7.200 m
2
Cross section of Stone masonry retaining wall (A4) = 1.600 m
2
Cross section of Stone masonry retaining wall (An) = 20.000 m
Weight of Stone masonry retaining wall (W) = 460.000 KN
height of line of action for lateral earth pressure (h4) = 2.667 m
1 Sin
Active earth pressure coeff. at base of wall (K p a ) = 0.333
1 Sin
A1 X1 A2 X 2 A3 X 3 A4 X 4
An
distance of W from X = 2.019 m

Vehicle load surcharge Intensity PH=(z-1+z)/2 x Z diff 2.247 KN

dist. of surcharge load from X=d = 0.59H for m 0.4 & 0.48H for m>0.4 4.720 m
Pa = K pa
Active earth pressure at base of wall x so x H 53.333 KN/m
Moment due to surcharge Load @ X = PH x d Overturning Moment 10.607 KNm
Moment due to selfweight of wall @ X = W x X Resisting Moment 928.587 KNm
Moment due to active earth pressure @ X =1/2 x Pa x h4 Overturning Moment 71.111 KNm

C Check against overturning:- For FOS = 2.75

Sum of resisting moment = Mres 928.587 KNm

Sum of Overturning moment = Myy over 81.718 KNm

Factor of safety against Overturning (FOS overturning) = 11.363 OK

D Check againstg Sliding:- For FOS = 2.75


Frictional coefficient = 0.450
Resisting force against sliding (W) = 207.000 KN

Sum of Sliding Forces ( Surcharge Load + Active earth pressure) = 55.580 KN

Factor of safety against Sliding (FOS sliding) = 207.000 / 55.580 3.724 OK


DESIGN OF STONE MASONRY RETAINING WALL

A Geometry Data :-
Height of Retaining wall from Top ground level to Top (h1) = 0.000 m
Height of Retaining wall from Formation Road Level to Top ground level (h2) = 8.000 m
Height of foundation from Formation Road Level (h3)or D = 1.000 m
Top head of retaining wall (Bt) = 0.6 m
Bottom width of retaining wall (Bb) = (For Initial section assume approx. 0.6H) 4.500 m
Surcharge load of Max. Vehicle axail load as per IRC6- 2000 [ Class A]= Load vehicle 70.632 KN
distance of Axle load from retaining wall top X 0.45 m
n
= angle bet resultant force and normal to failure plane/friction angle of soil 30

test report
From soil
3
Unit weight of stone masonry wall (s) = 23.000 KN/m
3
Unit weight of soil (so) = 20.000 KN/m

Frictional coefficient = 0.450

WALL TYPE : - W2 Y
bt= 0.6 m

h1= 0.000 m

A2

h2= 8.000 m H=h1+h2+h3= 9.000 m ka =(active earth pressure coefficient)


23/100
1/5

W= 574.425 KN
((A1 x X1) +(A2 x X2) + (A3 x X3) +(A4 x X4))/ An

Pa =1/2 x Pa x h4 = 90.000 KNm

Road Formation Level


A3 h4 = H/3 = 3.000 m
h3= 1.000 1.800 0.6 2.100 m
A1 '
X bb= 4.500 m
1/5 0.900 hv, m Pa=K p a x so x H = 60.000 KN/m
2

Binclined 4.589 m Active Soil pressure

B Design parameters:-
Total Height of retaining wall H = h1+h2+h3 = 9.000 m
m= 0.050
n= (assume multiple of 0.5) 18
x =1.77Qpm2n2/(H2(m2+n2)3
for m>0.4 or
m n Z = nH
0.28Qpm2n2/(H2(0.16+n2)3 for
PH

m0.4
0.050 0.056 0.500 0.242 0.120
0.050 0.111 1.000 0.238 0.118
0.050 0.167 1.500 0.234 0.116
0.050 0.222 2.000 0.231 0.115
0.050 0.278 2.500 0.230 0.115
0.050 0.333 3.000 0.230 0.115
0.050 0.389 3.500 0.232 0.116
0.050 0.444 4.000 0.233 0.117
0.050 0.500 4.500 0.235 0.118
0.050 0.556 5.000 0.237 0.119
0.050 0.611 5.500 0.238 0.119
0.050 0.667 6.000 0.239 0.120
0.050 0.722 6.500 0.240 0.120
0.050 0.778 7.000 0.241 0.121
0.050 0.833 7.500 0.241 0.121
0.050 0.889 8.000 0.242 0.121
0.050 0.944 8.500 0.242 0.121
0.050 1.000 9.000 0.243

P = H 2.013

Surcharge load from vehicle


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
0.245

0.240
x

0.235

0.230

0.225

0.220
Base length of triange A1 = 1.800 m
Base length of triange A3 = 2.100 m
Base length of triange A4 = 0.180 m
Distance of CG of A1 from X = X1 1.200 m
Distance of CG of A2 from X = X2 2.100 m
Distance of CG of A3 from X = X1 3.100 m
Distance of CG of A4 from X = X4 3.000 m
2
Cross section of Stone masonry retaining wall (A1) = 8.100 m
2
Cross section of Stone masonry retaining wall (A2) = 5.400 m
2
Cross section of Stone masonry retaining wall (A3) = 9.450 m
2
Cross section of Stone masonry retaining wall (A4) = 2.025 m
2
Cross section of Stone masonry retaining wall (An) = 24.975 m
Weight of Stone masonry retaining wall (W) = 574.425 KN
height of line of action for lateral earth pressure (h4) = 3.000 m
1 Sin
Active earth pressure coeff. at base of wall (K p a ) = 0.333
1 Sin
A1 X1 A2 X 2 A3 X 3 A4 X 4
An
distance of W from X = 2.259 m

Vehicle load surcharge Intensity PH=(z-1+z)/2 x Z diff 2.013 KN

dist. of surcharge load from X=d = 0.59H for m 0.4 & 0.48H for m>0.4 5.310 m
Active earth pressure at base of wall Pa = K pa x so x H 60.000 KN/m
Moment due to surcharge Load @ X = PH x d Overturning Moment 10.687 KNm
Moment due to selfweight of wall @ X = W x X Resisting Moment 1297.890 KNm
Moment due to active earth pressure @ X =1/2 x Pa x h4 Overturning Moment 90.000 KNm

C Check against overturning:- For FOS = 2.75

Sum of resisting moment = Mres 1297.890 KNm

Sum of Overturning moment = Myy over 100.687 KNm

Factor of safety against Overturning (FOS overturning) = 12.890 OK

D Check againstg Sliding:- For FOS = 2.75


Frictional coefficient = 0.450
Resisting force against sliding (W) = 258.491 KN

Sum of Sliding Forces ( Surcharge Load + Active earth pressure) = 62.013 KN

Factor of safety against Sliding (FOS sliding) = 258.491 / 62.013 4.168 OK


Hm Bt m Bb m Binclined m hv m Outward slope back slope
2.000 0.600 1.600 1.632 0.320 1/5 3/10
2.500 0.600 1.800 1.836 0.360 1/5 7/25
3.000 0.600 1.950 1.989 0.390 1/5 1/4
4.000 0.600 2.000 2.040 0.400 1/5 3/20
5.000 0.600 2.500 2.550 0.500 1/5 9/50
6.000 0.600 3.000 3.059 0.600 1/5 1/5
7.000 0.600 3.500 3.569 0.700 1/5 3/14
8.000 0.600 4.000 4.079 0.800 1/5 9/40
9.000 0.600 4.500 4.589 0.900 1/5 7/30

Bt
H

1m Bb
hv

Typical diagram with Stone masonry wall geometry


Cross Section area m2
2.456
3.324
4.205
5.600
8.375
11.700
15.575
20.000
24.975