Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
TESIS
INGENIERO MECANICO
HUANCAYO PER
2015
ASESOR
II
DEDICATORIA
III
RESUMEN
prueban que del 75 al 85% de todas las fallas en sistemas hidrulicos son
hidrulico puede ser detectado mediante el anlisis del fluido con el cual
IV
Toma de la muestra, envio de la muestra a laboratorio, descarga de valores
El Autor
V
ABSTRAC
This research originated from the need of the failure in the use of oil analysis as
a tool because statistics show that 75 to 85% of all hydraulic system failures are
336DL before reaching failure, in order to analyze the hydraulic oil which
336DL CAT. The proposed and developed in this work method gives us the
follows:
VI
categorizing sample quality, rating metallurgy components, creating combined
- The team M4T00110 And M4T00569, are the most critical equipment and
possible failure due to high contamination of Al, Cu, B, Fe, Na, Si and Mg in the
hydraulic system equipment and urgently needs to review the bank of valves,
packaging, the hydraulic pump and leakage lines for water pollution and has
coolant additives.
Concluding that the proposed oil analysis method identifies worn components
336DL.
The contribution of the work is to have a low-cost tool to identify the wear of the
elements for their respective monitoring and planning can implement this
AUTHOR
VII
INDICE DE CONTENIDOS
ASESOR II
DEDICATORIA III
RESUMEN IV
ABSTRAC VI
INDICE GENERAL IX
INDICE DE FIGURAS XII
INDICE DE TABLAS XIV
VIII
INDICE GENERAL
CAPITULO I
IX
CAPITULO II
MARCO TEORICO
2.1 ANTECEDENTES 7
2.1.1 ANTECEDENTES INTERNACIONALES 7
2.2 BASES TEORICAS 9
2.2.1 EXCAVADORAS HIDRULICAS 336DL 9
2.2.2 SISTEMA HIDRULICO DE IMPLEMENTOS 10
2.2.2.1 LA PLUMA, EL BRAZO Y EL CUCHARON 10
2.2.2.2 BOMBA HIDRULICA 10
2.2.2.3 FILTRO DE ACEITE HIDRULICO 12
2.2.2.4 CONTROL DE VLVULAS 12
2.2.2.5 CILINDROS HIDRULICOS 13
2.2.2.6 TANQUE HIDRAULICO 14
2.2.2.7 MANGUERAS 15
2.2.2.8 ACOMPLAMIENTOS 20
2.2.2.9 ACEITES LUBRICANTES 24
2.3 MARCO CONCEPTUAL 40
2.3.1 HERRAMIENTAS DEL MANTENIMIENTO PROACTIVO
EN FLOTAS DE MAQUINARIA PESADA 40
2.3.1.1 CONFIABILIDAD Y MANTENIMIENTO 40
2.3.1.2 ESTRATEGIAS DE MANTENIMIENTO 41
2.3.2 ANLISIS DE ACEITE 46
2.3.2.1 BENEFICIOS DE UTILIZAR EL ANLISIS
DE ACEITE 47
2.3.2.2 CIRCUITOS HIDRULICOS 53
2.3.3 ANALISIS DE ACEITE S.O.S. EN FERREYEROS SA 55
2.3.3.1 ANTECEDENTES DE LOS ACEITES EN
LA INDUSTRIA 55
2.3.3.2 TOMA DE MUESTRA DE ACEITE PARA
ANALISIS S.O.S 57
2.3.3.3 TIPOS DE ANALISIS DE ACEITE QUE
REALIZA EL LABORATORIO S.O.S. 62
2.3.3.4 PRUEBAS FISICAS 65
2.3.3.5 CDIGOS DE NIVELES DE LIMPIEZA 75
2.3.4 LA METALURGIA EN LOS COMPONENTES DEL
SITEMA HIDRAULICO 78
2.4 SISTEMA DE HIPOTESIS 82
2.4.1 HIPOTESIS GENERAL 82
2.5 SISTEMAS DE VARIABLES 82
2.5.1 VARIABLE INDEPENDIENTE 82
X
2.5.2 VARIABLE DEPENDIENTE 83
2.6 OPERACIONALIZACION DE VARIABLES 83
2.6.1 VARIABLE DE ENTRADA 83
2.6.2 VARIABLE DE SALIDA 84
CAPITULO III
DISEO METODOLOGICO
CAPITULO IV
CONCLUSIONES
RECOMENDACIONES
BIBLIOGRAFIA
ANEXOS
XI
INDICE DE FIGURAS
XII
FIGURA N2.18: Alistar la manguera de succin 60
FIGURA N2.19: Alistar la bomba de vaco o succin 61
FIGURA N2.20: Insertar la manguera al aceite 61
FIGURA N2.21: Bombear para recoger la muestra 62
FIGURA N2.22: Envo de muestra 62
FIGURA N2.23: Equipo plasma ICP 63
FIGURA N2.24: Equipo contador de partculas 77
FIGURA N 4.1: Informe de Laboratorio S.O.S 91
FIGURA N 4.2: Seleccin de indicadores 92
FIGURA N 4.3: Concentracin de Aluminio en partculas por milmetro 95
FIGURA N 4.4: Concentracin de Boro en partculas por mililitro 96
FIGURA N 4.5: Concentracin de Calcio en partculas por mililitro 97
FIGURA N 4.6: Concentracin de Cromo en partculas por mililitro 98
FIGURA N 4.7: Concentracin de Cobre en partculas por mililitro 99
FIGURA N 4.8: Concentracin de Fierro en partculas por mililitro 100
FIGURA N 4.9: Concentracin de Potasio en partculas por mililitro 101
FIGURA N 4.10: Concentracin de Magnesio en partculas por mililitro 102
FIGURA N 4.11: Concentracin de Sodio en partculas por mililitro 103
FIGURA N 4.12: Concentracin de Fsforo en partculas por mililitro 104
FIGURA N 4.13: Concentracin de Silicio en partculas por mililitro 105
FIGURA N 4.14: Concentracin de Zinc en partculas por mililitro 106
FIGURA N 4.15: Deteccin de componentes 115
FIGURA N 4.16: Plantilla de Datos Numericos Enteros 116
FIGURA N 4.17: Plantilla de datos Numericos Decimales 116
XIII
INDICE DE TABLAS
XIV
Tabla N 4.4: Clasificacin y cdigo segn tabla ISO 4406 107
Tabla N 4.5: Categorizacin de Calidad de Muestra de Aceite 107
Tabla N 4.6: Categorizacin de Calidad de la muestra de aceite - I 109
Tabla N 4.7: Tabla de metalurgia y composicin de metales en componentes
hidrulicos 110
Tabla N 4.8: Categorizacin de calidad de muestra de aceite - II 111
Tabla N 4.9: Categorizacin de calidad de muestra de aceite - III 111
Tabla N 4.10: Plantilla Master final para procesamiento de deteccin de
componentes desgastados 111
XV
CAPITULO I
embargo hay muchos factores que trabajan para erosionar esa eficiencia
1
Aplicando el sistema de monitoreo de condicin, mediante el anlisis
siguiente:
ACEITE MANDOS DE
ACEITE HIDRAULICO
FILTRO HIDRAULICO
FILTRO HIDRAULICO
ANALISIS ACEITE DE
TRAMPA DE AGUA
ACEITE DE MOTOR
TIPO DE SERVICIO
FILTRO RETORNO
ACEITE MANDOS
ANALISIS ACEITE
MANO DE OBRA
FILTRO ACEITE DE
COMBUSTIBLE
FILTRO ACEITE
SECUNDARIO
HIDRAULICO
FILTRO AIRE
FILTRO AIRE
COSTO POR
ROTACION
PRIMARIO
RETORNO
SERVICIO
TANQUE
MOTOR
FINALES
PILOTO
MOTOR
2
85% de todas las fallas en sistemas hidrulicos son resultado directo de la
planificadas, etc.
manera.
3
1.3 OBJETIVOS
1.4 JUSTIFICACION
Caterpillar, ya que las estadsticas prueban que del 75 al 85% de todas las
fluido.
las empresas que trabajan con estos equipos puedan tomar decisiones
mismas fallas.
4
1.4.1 Nivel Cientfico: Se tom como base los fundamentos cientficos
pesado.
mantenimiento.
que los usuarios finales tomen las mejores decisiones sobre los
resultados.
5
1.4.5 Importancia del tema de Investigacin
siguientes razones.
1.5 LIMITACIONES
ellos:
presente trabajo
6
CAPITULO II
MARCO TEORICO
2.1 ANTECEDENTES
7
contaminacin como motores, cajas de engranajes, compresores y
analizar los datos con cierta frecuencia, para que esta herramienta sea
beneficios.
8
desgaste de metal o corrosin del eje. Adems, durante el servicio, la
1990)
(Ferreyros, 2012)
9
FIGURA N2.1: Vista esquemtica de la excavadora hidrulica
10
energa hidrulica en forma de flujo de fluido. Todas las bombas
11
2.2.2.3 FILTRO DE ACEITE HIDRULICO
i
FIGURA N2.3: Vista esquemtica del sistema hidrulico tpico
12
hidrulicos actuales. Su funcin es dirigir, controlar o mantener la
a) PIEZAS DE VLVULA:
Cuerpo
Carrete
Resortes
Sellos
b) TIPOS DE VLVULAS
13
convierten la energa hidrulica en energa mecnica. (Ferreyros,
2012)
1. Vstago.
3. Cncamo de la cabeza.
6. Puntos de conexin.
7. Pistn.
14
tanques disipan el calor que se acumula en el aceite hidrulico, y los
2.2.2.7 MANGUERAS
Las mangueras se construyen en capas y tienen tres componentes
a) CAMISA DE LA MANGUERA
con el tubo interior, el material del tubo debe ser compatible con la
15
b) REFUERZO
c) MATERIALES DE REFUERZO
(Ferreyros, 2012)
16
d) RECUBRIMIENTO
e) NORMAS INDUSTRIALES
17
f) NORMA SAE
g) NORMA DIN
18
h) NORMA JIS
estn marcadas con las letras JIS. Las normas JIS clasifican las
j) TEMPERATURA
19
para trabajar a otras gamas de temperaturas, su vida til se reducir.
(Ferreyros, 2012)
k) TEMPERATURA AMBIENTE
2.2.2.8 ACOMPLAMIENTOS
(Ferreyros, 2012)
acoplamientos Caterpillar:
3. Factor de corte
4. Longitud de cada
6. ngulo de flexin
7. Espesor de la cabeza
20
8. ngulo de asiento (no mostrado)
b) DIMETRO DE LA CABEZA
- Mtrica (mtrico)
21
Estas normas especifican las roscas por su dimetro y paso. Las
(Ferreyros, 2012)
e) PASO DE LA ROSCA
f) ANGULO DE FLANCO
22
roscas se forman en relacin unas con otras. Las roscas
(Ferreyros, 2012)
a) ACOPLAMIENTOS PERMANENTES
2012)
23
en las de motor/frenos de aire (1130). Los acoplamientos de tornillo
a) Controlar la friccin
b) Controlar el desgaste
c) Controlar la corrosin
d) Controlar la temperatura
e) Controlar la contaminacin
f) Transmitir potencia
Sellar el espacio entre piezas: Dado que las superficies metlicas son
24
Mantener limpio el circuito de lubricacin: en el caso de los lubricantes
a) COLOR Y FLUORESCENCIA
25
la cantidad y naturaleza de los aditivos usados. El color tiene poco
b) VISCOSIDAD
26
fro. Al momento de seleccionar el aceite apropiado para una
I. Viscosidad Cinemtica
Por otra parte, el tiempo que tarda en fluir un volumen dado de fluido
Dnde:
d: La densidad,
27
II. Viscosidad Dinmica
c) UNTUOSIDAD
d) PUNTO DE INFLAMACIN
28
incendios a causa de los vapores y procesos no adecuados en la
e) PUNTO DE COMBUSTIN
f) PUNTO DE CONGELACIN
29
g) ACIDEZ
aditivos.
(Ferreyros, 2012)
30
establecidos para el aceite para evitar daos en los equipos o
h) DEMULSIBILIDAD
(Ferreyros, 2012)
31
diseado una nomenclatura segn el tipo de motor al que se le va a
32
performance han sido diseados para simular reas y condiciones
tablas:
Motores de gasolina
Fuera de Para motores de 1996 o ms antiguos. Vlido cuando est precedido por las
SH
circulacin categoras C actuales.
Fuera de
SG Para motores de 1993 o ms antiguos.
circulacin
Fuera de
SF Para motores de 1988 o ms antiguos.
circulacin
33
Categora Estado Servicio
Motores disel
34
Categora Estado Servicio
Fuera de
CD-II Presentado en 1985. Para motores con ciclo de dos tiempos.
circulacin
35
Tabla N2.0.3: Tipo de lubricante para transmisiones
Aceites que
Transmisiones Industriales para tornillos sin
GL2 contienen materiales
fin
grasos
Aceites con
Transmisiones Manuales Engranajes
GL-3 aditivacin
Cnicos poco sometidos a esfuerzo
antidesgaste
Aceites con media
aditivacin EP Transmisiones Manuales. Engranajes
GL4 (Extrema Presin). hipoides medianamente sometidos a
Equivalente a la esfuerzos.
Norma MIL-L-21105
Aceites con alta
aditivacin EP Engranajes hipoides muy sometidos a
GL-5 (Extrema Presin). esfuerzos. Puede ser usado para
Equivalente a la Transmisiones Manuales.
Norma MIL-L-2105 D
36
representando cada nmero SAE un rango de viscosidad expresada
37
Tabla N2.0.4: Tipo de lubricantes segn norma SAE
Viscosidad Cinemtica c
Grado SAE
St @ 100C
0W 3,8
5W 3,8
10W 4,1
15W 5,6
20W 5,6
25W 9,3
20 5,6 a 9,3
30 9,3 a 12,5
40 12,5 a16,3
50 16,3 a21,9
60 21,9 a 6,1
38
de los lubricantes porque evita la posibilidad de una mala utilizacin
(BONILLA, 2011)
39
d) Segn normas ASTM
40
Una alta disponibilidad no implica necesariamente una alta
logra una alerta temprana que permite planificar una parada para
41
corregir el problema, alcanzando de sta manera una mayor
beneficios:
42
costos de aplicacin de la estrategia sean menores a los que se tratan
Inspecciones de la maquinaria
2005)
43
El punto P, primer momento en que la causa de falla es detectable por
prdidas de produccin
44
Al igual, que para el caso del Monitoreo de Condicin debe enfocarse
control para cada una de ellas, los tipos de anlisis que se efectuarn,
maquinaria. Una vez que se han identificado la causa raz que genera
45
mquina no est experimentando una prdida en su desempeo o
(Altman, 2005)
Controlar la friccin
Controlar el desgaste
Controlar la corrosin
Controlar la temperatura
Controlar la contaminacin
respecto a:
Desgaste de la maquinaria
46
El anlisis de aceite no slo va a permitir monitorear el estado de
2005)
Alarmas Absolutas
Alarmas Estadsticas
47
olvidar la variabilidad inherente a la propia exactitud de las pruebas
Resulta muy importante para poder identificar las causas de falla tener
48
El objetivo de limpieza afecta desde la recepcin, almacenaje y
siguientes mecanismos:
Oxidacin
Polimerizacin
Ruptura
Evaporacin
49
Al disminuir la contaminacin con agua, con aire, con partculas, con
a) Motores disel
Espectroscopia de Silicio
Contenido de Agua
50
que el mayor contenido de holln en el aceite, provoca un mayor
51
Los puntos alrededor de la muestra, presentan un contenido de hierro
52
Por otra parte es posible elaborar un indicador del estado de un motor
Cromo, y Nquel
Espectroscopia de Silicio
Contenido de Agua
Oxidacin
Conteo de partculas
53
Las estadsticas prueban que del 75 al 85% de todas las fallas en
54
En la figura N 2.13, est graficada la evolucin de viscosidad
El fluido ATF posee un muy alto ndice de viscosidad, con el uso sufre
Los aceites han ido evolucionando para atender a las exigencias cada
S.O.S, 2011)
55
2.3.3.1.1 API y Los Motores Disel Con Cmara De
Precombustion Caterpillar
Caterpillar
56
b) En 1995: API lanza la categora CG-4, diseada para operar en los
decir que tienen doble poder de dispersin que los aceites CG-4.
decir que tienen mejor poder de dispersin que los aceites CH-4.
57
PASO 1: Haga funcionar el motor a velocidad baja en vaco y quite la
58
PASO 3: Vuelva a insertar la sonda en la vlvula y llene tres cuartas
59
2.3.3.2.3 Usando El Mtodo De Extraccin Por Vaco
para los sistemas bajo presin que no estn equipados con vlvulas
60
FIGURA N2.19: Alistar la bomba de vaco o succin
61
FIGURA N2.21: Bombear para recoger la muestra
62
2.3.3.3.1 DETECCION DE ELEMENTOS DE DESGASTE
Contaminantes y Aditivos. Cu, Fe, Cr, Ni, Ti, V, Cd, Ag, Pb, Sn, Al, Si,
63
2.3.3.3.2 ANALISIS DE LA CONDICION DEL ACEITE
64
- Operacin deficiente del inyector de combustible.
- Altas temperaturas
- Presencia de cobre
65
componentes del motor. Durante la combustin, el azufre del
- Humedad
- Temperaturas de ambiente
- Temperaturas de combustin
Glicol en el aceite.
66
aceite crea una emulsin que obstruye el filtro. El agua y el
- Condensacin en el crter
tuberas.
67
muestra de aceite), si hay presencia de glicol, se producir un
generalmente indica:
68
posee en suspensin. La mayora de estas clasifican el grado de
los manuales a los automticos, pasando por los pticos y por los
a) Contadores pticos.
69
una partcula por el haz. Cuando el haz golpea la partcula se
S.O.S, 2011)
70
sedimentos o carbonilla. Esto puede dar lugar a errores de medida,
2011)
pticos automticos.
- Eaton
- HIAC-PODS
- Internormen-Filter-CCS2
- MP Filtri USA-LPA2
71
- Pall Corp. PFC400W
- Pamas GmbH-S-2
- Pamas GmbH-SBSS
- Pamas GmbH-S-40
- Pamas GmbH-OLS
- Pamas GmbH-OLMS
- Pamas GmbH-SVSS
- PDK-PALS
- Stauff Corp.-LasPaCI
- Webtec Products-DLPC
72
disel o altamente contaminados, los equipos por bloqueo de poro
S.O.S, 2011)
colmado la pantalla.
73
Como ejemplos de contadores de partculas que utilizan estos
- Rockwell Automation/Entek-Contam-Alert
74
Una gran prdida de energa, en el caso de los contadores de
75
el primero corresponde al nmero total de partculas superiores a
Tabla N2.0.2: Diferencia entre las normas ISO 4406(1987) Y ISO (1999)
76
FIGURA N2.24: Equipo contador de partculas
Fuente: (Ferreyros, separata S.O.S, 2011)
Motores
22
Muy 20000Limpio 40000 Sucio
Limpio
23 40000 80000
Muy
Turbinas 24 Limpio 80000 Sucio 160000
Limpio
25 160000 320000
Fuente:
26 (Ferreyros, separata
320000 S.O.S, 2011)
640000
27 640000 1300000
2.3.4 LA METALURIGA 28 EN LOS 1300000COMPONENTES 2500000 DEL SISTEMA
HIDRAULICO
78
endurece por el temple y una vez templado, tiene la propiedad
Automotriz)
79
c) El Aluminio: Es un metal suave, blanco y de peso ligero, al ser
Automotriz)
80
cojinetes, bocinas a su eje rotativo. Se utiliza tambin en la
Automotriz)
81
h) El Sodio.- Es un elemento metlico blanco plateado,
(Tecnologia Automotriz)
82
2.5.2 VARIABLE DEPENDIENTE
OPERACIONALIZACION DE VARIABLES
VARIABLE INDICADOR O DATO TIPO DE
DIMENSION
ENTRADA CATEGORIA FINAL VARIABLE
ALUMINIO PPM NUMERICA CONTINUA
BORO PPM NUMERICA CONTINUA
CALCIO PPM NUMERICA CONTINUA
CROMO PPM NUMERICA CONTINUA
COBRE PPM NUMERICA CONTINUA
FIERRO PPM NUMERICA CONTINUA
CONCENTRACION DE PARTICULAS
POTASIO PPM NUMERICA CONTINUA
ANALISIS DE ACEITE HIDRAULICO MAGNESIO PPM NUMERICA CONTINUA
SODIO PPM NUMERICA CONTINUA
FOSFORO PPM NUMERICA CONTINUA
SILICE PPM NUMERICA CONTINUA
ZINC PPM NUMERICA CONTINUA
14 P ml NUMERICA CONTINUA
CONTEO DE PARTICULAS 4 P ml NUMERICA CONTINUA
6 P ml NUMERICA CONTINUA
83
2.6.2 VARIABLE DE SALIDA
OPERACIONALIZACION DE VARIABLES
VARIABLE INDICADOR O DATO TIPO DE
DIMENSION
SALIDA CATEGORIA FINAL VARIABLE
COJINETES Fe, Cu, Pb, Sn ppm Numerica Continua
VARILLAS O VASTAGOS Fe, Cr ppm Numerica Continua
BOCINAS Cu ppm Numerica Continua
CILINDROS Fe, Pb ppm Numerica Continua
EMPAQUES Al ppm Numerica Continua
ENGRANAJES Fe ppm Numerica Continua
GUIAS Cu, Zn ppm Numerica Continua
COMPONENTES DESGASTADOS ADITIVOS Si, Na, Zn ppm Numerica Continua
PISTONES Fe, Cu, Pb, Sn ppm Numerica Continua
BOMBAS Fe ppm Numerica Continua
SPOOLS Fe,Cu ppm Numerica Continua
VALVULAS Fe, Cr ppm Numerica Continua
AGUA Mg ppm Numerica Continua
TIERRA Si ppm Numerica Continua
Codigo ISO 4406 CALIDAD DE MUESTRA CATEGORIA DICOTOMICO
84
CAPITULO III
DISEO METODOLGICO
85
de fuentes bibliogrficas, hemerogrficas o archivsticas; la primera se
investigacin.
86
Tabla N3.0.1: Diseo de la Investigacin
3.4 POBLACION
Caterpillar
3.5 MUESTRA
87
Tabla N 3.0.1: Muestra de Observacin
M4T00569 3
M4T00110 1
M4T00116 7
M4T00118 8
M4T00121 1
M4T00134 10
M4T00185 1
M4T00188 4
M4T00202 5
M4T00204 2
M4T00208 3
M4T00211 1
M4T00222 3
M4T00354 1
M4T00427 1
M4T00430 2
M4T00441 2
M4T00447 6
M4T00455 3
M4T00611 2
M4T00614 5
M4T00619 1
TOTAL: 22 72
88
- Tablas dinmicas
- Fichas de lectura
tiles a la investigacin.
desgastados.
- Elaborar conclusiones
89
CAPITULO IV
90
b) Envi de la muestra a Laboratorio S.O.S de Anlisis de
Fluidos de Ferreyros SA.
91
d) Se realiza la seleccin de indicadores obtenidos en informe
de anlisis S.O.S.
92
Tabla N4.1: Cuadro de resultados de muestras de aceite hidrulico Parte 1
ANALISIS DE ACEITE
horometro de equipo dimensiones
Numero
MUESTRA concentracion de metal en partes por millon (ppm) conteo de particulas VISCOCIDAD PQ ISO
de
muestra EXCAVADORA M4T V100 (T
Al B Ca Cr Cu Fe K Mg Mn Mo Na Ni P Pb Si Zn 25 21 14 10 6 4 6/14
HOROMETRO equipo fluido Operacin)
1 M4T00569 659 236 27 0 2208 1 6 46 8 9 1 0 10 0 817 0 72 931 13 31 444 2897 23485 65635 6.6 48 23/22
2 M4T00569 891 467 26 3 2447 1 7 40 8 11 1 1 10 0 940 0 68 1035 3 7 20 48 8353 78082 6.3 38 23/20
3 M4T00569 700 278 28 1 2387 1 7 46 9 9 1 1 11 0 845 1 78 1070 1 2 6 32 13987 81495 6.5 42 24/21
4 M4T00110 4447.9 2447.9 4 0 231 1 25 78 3 100 1 0 2 1 822 0 9 1088 11 17 81 226 1570 26438 6.7 63 18/14
5 M4T00116 9000 150 12 0 3111 2 5 15 2 18 0 0 4 0 1133 0 14 1281 68 109 922 5084 29012 61671 6.3 66 22/17
6 M4T00116 8485 485 8 0 3005 1 6 12 4 20 0 0 4 0 1147 1 14 1282 6 12 45 172 1253 18468 6.2 60 17/13
7 M4T00116 8120 1500 9 0 2391 1 6 10 2 24 0 0 4 0 1086 0 16 1193 5 6 25 129 2482 25580 6.3 41 18/12
8 M4T00116 8018 2018 11 1 3093 1 11 15 4 38 0 0 4 0 1096 1 23 1252 5 9 37 98 509 5311 6.1 53 16/12
9 M4T00116 7941 1941 12 2 3061 1 10 14 3 40 0 0 3 0 1009 0 24 1241 5 8 20 60 370 5755 6.3 45 16/11
10 M4T00116 7492 1500 9 0 3099 1 9 13 3 39 0 0 2 0 1041 1 20 1175 3 5 47 236 2553 15265 6.3 36 19/13
11 M4T00116 7491 1941 6 0 3089 2 3 13 2 12 0 0 3 0 1128 0 9 1272 2 5 11 29 270 27210 6.1 50 15/11
12 M4T00118 9004 1004 3 2 3007 0 3 17 3 19 0 0 3 0 1086 0 6 1253 8 14 74 296 1768 14392 6.4 51 18/13
13 M4T00118 8924 250 3 2 3300 0 4 15 2 22 0 0 2 0 1040 0 7 1223 2 6 15 36 228 6990 6.3 51 15/11
14 M4T00118 8144 2000 4 3 3619 0 5 19 4 24 1 0 2 0 1007 0 8 1167 4 5 9 20 83 9777 6.5 54 14/10
15 M4T00118 7725 1725 3 4 3607 0 5 7 3 27 0 0 1 0 980 0 8 1108 7 13 48 141 990 5526 6.4 84 17/13
16 M4T00118 7500 1500 4 5 3937 0 6 9 3 32 0 0 1 0 924 0 11 1097 2 2 15 47 253 1804 6.5 36 15/11
17 M4T00118 7000 500 5 5 3914 0 5 8 3 37 0 0 2 0 927 0 10 1069 1 2 7 20 165 2146 6.7 23 15/8
18 M4T00118 6500 500 3 5 3742 0 4 7 3 39 0 0 0 0 847 0 9 954 0 1 9 35 407 6449 6.8 46 16/10
19 M4T00118 6000 496 6 6 3659 0 10 12 2 89 1 0 5 0 979 1 14 1070 5 13 87 364 2217 13113 6.6 24 18/14
20 M4T00121 11275.2 2000 6 11 548 1 14 74 2 101 2 0 2 1 833 0 12 962 2 2 4 16 106 2666 6.6 51 14/9
21 M4T00134 11871.1 1050 2 1 205 1 11 2 1 31 1 0 2 0 796 0 4 978 3 6 38 162 2992 21630 6.9 43 19/12
22 M4T00134 11185 1050 2 1 193 1 10 20 0 25 0 0 1 0 717 0 3 982 2 3 18 66 463 6519 7 40 16/11
23 M4T00134 10030 2030 4 2 233 1 21 52 3 76 1 0 2 1 936 1 6 954 4 8 72 280 1696 8355 6.7 48 18/13
24 M4T00134 9755 4750 3 3 218 1 18 49 3 70 1 0 2 1 834 1 6 947 3 4 14 50 376 4431 6.7 47 16/11
25 M4T00134 8761 731 4 4 215 1 19 51 3 86 1 0 2 1 789 1 6 981 4 6 18 37 134 961 6.8 39 14/11
26 M4T00134 8270 2249 4 4 218 1 20 54 2 79 1 0 1 1 756 1 5 980 2 3 12 29 186 1459 6.8 42 15/11
27 M4T00134 8030 2000 4 4 224 1 21 55 21 83 1 0 2 1 766 0 5 1001 5 7 20 61 310 2762 6.7 35 15/11
28 M4T00134 7503 1482 4 4 189 1 18 50 18 86 1 0 2 0 793 0 4 907 1 2 4 18 179 2802 6.9 31 15/9
29 M4T00134 7266 1245 3 4 233 1 17 48 17 86 1 0 2 1 755 0 4 979 3 6 28 100 834 7432 7.2 39 17/12
30 M4T00134 6987 966 3 4 188 1 22 54 22 93 1 0 2 1 824 0 4 998 0 1 5 15 81 621 6.9 33 14/9
31 M4T00185 8364.2 364 3 0 2901 3 9 56 2 16 1 0 2 1 1041 0 10 1279 4 8 75 359 9737 53829 6.4 56 20/13
32 M4T00188 4127.8 2000 3 0 235 5 8 34 2 15 1 0 2 0 733 0 10 910 6 8 38 148 1614 14729 6.7 49 18/12
33 M4T00188 3221 2250 2 1 187 3 8 31 2 11 1 0 2 0 760 0 8 981 2 8 138 980 8243 23884 6.9 45 20/14
34 M4T00188 3103.3 1000 2 0 175 2 7 27 1 12 1 0 2 0 710 1 8 905 11 19 116 624 5729 20370 6.9 35 20/14
35 M4T00188 2952.8 680 2 0 174 2 7 29 2 9 1 0 2 1 763 0 9 961 8 15 46 116 718 5951 6.9 38 17/13
93
Fuente: Elaboracin Propia
Tabla 4.2: Cuadro de resultados de muestras de aceite hidrulico Parte 2
ANALISIS DE ACEITE
horometro de equipo dimensiones
Numero
MUESTRA concentracion de metal en partes por millon (ppm) conteo de particulas VISCOCIDAD PQ ISO
de
muestra EXCAVADORA M4T V100 (T
Al B Ca Cr Cu Fe K Mg Mn Mo Na Ni P Pb Si Zn 25 21 14 10 6 4 6/14
HOROMETRO equipo fluido Operacin)
36 M4T00202 4168 2168 3 0 230 8 9 42 4 8 1 0 3 1 759 1 7 981 5 8 171 817 3037 12665 6.8 56 19/15
37 M4T00202 3380 1380 3 0 221 5 8 32 2 6 1 0 2 1 707 1 6 903 3 7 42 126 566 3267 6.8 53 16/13
38 M4T00202 3131 2000 3 0 222 5 7 34 1 8 1 0 3 0 733 1 6 956 3 4 20 92 1657 10938 6.8 52 18/11
39 M4T00202 2683 683 2 0 214 5 7 32 2 6 1 0 2 0 723 0 5 948 2 4 13 28 147 2581 6.6 46 14/11
40 M4T00202 2025 2000 2 0 339 6 12 42 3 12 1 0 5 1 773 1 7 977 15 42 314 827 3021 9421 6.6 37 19/15
41 M4T00204 2645 1645 2 0 214 2 6 21 1 7 0 0 1 0 758 1 5 999 3 5 23 69 403 4705 6.8 47 16/12
42 M4T00204 2357 2000 3 0 201 3 12 27 2 7 1 0 1 0 791 1 8 996 2 4 17 120 1938 14786 6.6 52 18/11
43 M4T00208 4653 428 3 0 281 2 5 35 3 4 1 0 1 0 818 0 5 991 3 5 17 55 380 5149 6.8 44 16/11
44 M4T00208 4221 2221 6 1 400 3 8 57 2 4 1 0 2 0 773 0 10 943 11 19 102 320 295 13520 6.7 59 18/14
45 M4T00208 3649 1649 2 0 334 2 7 55 2 7 1 0 2 0 759 1 5 963 3 4 18 89 1143 8944 6.9 59 17/11
46 M4T00211 4967 543 1 4 585 0 3 34 1 92 0 0 1 0 810 0 2 879 5 10 90 652 5850 29156 7 63 20/14
47 M4T00222 5999 250 3 0 200 13 16 29 4 41 1 0 3 1 742 1 4 945 5 6 16 61 613 6083 6.7 47 16/11
48 M4T00222 5541 2541 3 0 195 11 16 28 4 39 1 0 3 1 793 1 3 939 6 8 30 128 1422 11611 6.6 32 18/12
49 M4T00222 4098 2098 2 1 193 7 17 20 4 59 1 0 4 1 739 1 4 782 11 18 40 86 460 3539 6.8 34 16/12
50 M4T00354 12559 1494 1 0 221 3 16 15 2 3 0 0 1 0 748 1 4 960 380 704 2000 5693 20455 48769 6.7 761 21/19
51 M4T00427 11048 857 3 0 206 2 9 14 2 7 0 0 2 0 734 0 4 968 8 13 35 183 2688 14357 6.8 37 16/12
52 M4T00430 1983 1983 7 0 169 1 17 31 4 9 1 0 3 0 792 1 20 959 4 11 71 313 4727 39308 6.5 38 19/13
53 M4T00430 990 990 6 0 176 1 10 21 2 7 0 0 3 0 681 1 17 867 4 6 14 89 3132 42047 6.5 29 19/11
54 M4T00441 2023 2000 1 0 204 1 11 9 4 2 0 0 3 0 758 1 2 987 16 37 203 692 4162 22541 6.2 34 19/15
55 M4T00441 993 993 1 0 188 1 9 5 3 4 0 0 1 0 799 1 1 989 7 16 67 211 975 6246 6.5 46 17/13
56 M4T00447 6783 1918 1 0 110 1 13 21 2 39 1 0 1 0 754 1 3 961 3 6 20 50 239 2453 6.8 44 15/12
57 M4T00447 661 1806 2 0 142 1 12 21 2 52 1 0 1 0 769 1 2 1009 5 11 76 238 1322 6811 7 40 18/13
58 M4T00447 5683.2 1228.9 1 0 124 1 10 17 3 38 1 0 1 0 791 1 2 980 16 34 98 277 1254 8395 6.8 37 17/14
59 M4T00447 5141 686 1 0 120 1 9 16 1 42 0 0 0 0 783 1 1 944 4 8 25 152 1580 7579 6.6 38 18/12
60 M4T00447 4454 2103 1 0 115 1 11 28 3 72 1 0 2 0 799 1 2 1059 22 36 152 594 3551 31702 6.4 45 19/14
61 M4T00447 3857.2 631.3 0 0 287 1 8 14 2 69 0 0 1 0 770 0 2 948 3 5 30 218 1389 16864 6.6 38 18/12
62 M4T00455 3103.1 1103 1 0 209 1 5 18 2 3 0 0 1 0 708 0 2 938 181 303 1087 2392 7965 30650 6.8 920 23/17
63 M4T00455 3103.1 991 1 0 183 1 5 14 2 5 0 0 1 0 705 0 1 901 29 50 283 865 4727 28260 6.6 35 19/15
64 M4T00455 2809 697 1 0 200 1 6 12 2 4 0 0 1 0 797 0 1 921 14 40 466 1720 4587 9932 6.9 37 19/16
65 M4T00611 7382 2000 8 0 217 2 8 25 4 7 1 0 1 0 649 1 16 841 5 8 16 41 304 6966 6.4 30 15/11
66 M4T00611 5999 2000 4 0 209 2 7 16 2 6 0 0 1 0 665 0 6 589 12 22 65 237 1340 6625 6.5 37 18/13
67 M4T00614 2934 658 1 0 189 1 5 20 3 18 0 0 1 0 790 1 2 994 26 41 97 164 740 6080 6.7 52 17/14
68 M4T00614 2832 20 0 0 178 1 5 6 1 18 0 0 1 0 777 0 2 987 5 7 21 40 186 1548 6.9 38 15/12
69 M4T00614 2822 1466 1 0 179 1 6 17 2 19 0 0 1 0 783 1 2 972 8 13 79 266 1697 10192 6.8 35 18/13
70 M4T00614 1466 230 1 0 201 2 8 14 4 32 0 0 2 0 791 1 3 990 3 5 20 58 266 3206 6.6 36 15/12
71 M4T00614 159 59 0 0 253 0 8 6 3 3 0 0 1 0 775 0 2 907 4 5 20 60 566 16243 6.7 29 16/12
72 M4T00619 2758 672 1 0 255 1 25 20 1 36 1 0 2 0 768 1 3 987 18 28 90 199 695 3839 6.6 39 17/14
94
Fuente: Elaboracin Propia
f) Se realiza la operacionalizacion de los datos de la
concentracin de metales en ppm (partes por milln) para
determinar el nmero de muestras crticas.
anlisis.
Concentracion de Al en PPM
50
45
40
Numero de muestras
35
30
25
20
15
10
5
0
0 2 6 10 14 18 22 26 30
Concentracion de Al en
0 46 16 5 2 0 0 3 0
PPM
95
2.- Boro (boro)
anlisis.
Concentracion de B en ppm
60
50
Numero de Muestras
40
30
20
10
0
0 1 3 5 7 9 11 13 15
Concentracion de B en
0 52 7 11 1 0 1 0 0
ppm
3.-Calcio (Ca)
para el anlisis.
96
Concentracion de Ca en ppm
60
50
Numeo de muestras
40
30
20
10
0
3625.
0 377 911 1445 1979 2513 3047 4200
5
Concentracion de Ca en ppm 0 53 0 0 1 3 9 6 0
anlisis.
97
Concentracion de Cr en ppm
50
45
40
Numeo de muestras 35
30
25
20
15
10
5
0
0 1 3 5 7 9 11 13 15
Concentracion de Cr en
0 47 16 4 2 1 1 1 0
ppm
anlisis.
98
Concentracion de Cu en ppm
30
25
Numero de Muestras 20
15
10
0
1 5 9 13 17 21 25 29 33
Concentracion de Cu en
0 21 27 9 8 5 2 0 0
ppm
anlisis.
99
Concentracion de Fe en ppm
25
20
Numeo de muestras
15
10
0
0 10.5 21.5 32.5 43.5 54.5 65.5 76.5 88
Concentracion de Fe en
0 23 16 15 6 10 0 2 0
ppm
anlisis.
100
Concentracion de K en ppm
25
20
Numeo de muestras 15
10
0
10.8 13.9 17.0 20.1
0 1.55 4.65 7.75 23
5 5 5 5
Concentracion de K en
0 23 16 15 6 10 0 2 0
ppm
anlisis.
101
Concentracion de Mg en ppm
35
30
Numeo de muestras
25
20
15
10
5
0
22.8 36.7 50.6 64.5 78.4 92.3
0 8.95 105
5 5 5 5 5 5
Concentracion de Mg en
0 30 12 14 1 3 4 8 0
ppm
anlisis.
102
Concentracion de Na en ppm
35
30
Numeo de muestras
25
20
15
10
0
0 0.8 2.4 4 5.6 7.2 8.8 10.4 12
Concentracion de Na en
0 30 12 14 1 3 4 8 0
ppm
para el anlisis.
103
Concentracion de P en ppm
30
25
Numeo de muestras 20
15
10
0
683. 753. 822. 892. 961. 1031 1100
550 1170
75 25 75 25 75 .25 .75
Concentracion de P en
0 8 26 21 1 5 5 6 0
ppm
anlisis.
104
Concetracion de Si en ppm
30
25
Numeo de muestras 20
15
10
0
0 6.4 17.2 28 38.8 49.6 60.4 71.2 82
Concetracion de Si en
0 8 26 21 1 5 5 6 0
ppm
105
Concentracion de Zn en ppm
30
Numeo de muestras
25
20
15
10
5
0
637.3 734.0 830.7 927.4 1024. 1120. 1217.
560 1316
5 5 5 5 15 85 55
Concentracion de Zn en ppm 0 1 1 3 27 26 4 10 0
siguiente tabla:
106
g) Categorizacin de la calidad de la muestra de aceite
Cdigo ISO ----- 12/9 ----- 14/11 ----- 16/13 ----- 18/15 ----- 20/17 ----- 22/19 ----- 24/21 ----- 26/23
Fluidos Muy
Limpio Sucio
Hidrulicos Limpio
Caja de Muy
Limpio Sucio
cambios Limpio
Muy
Motores Limpio Sucio
Limpio
Muy
Turbinas Limpio Sucio
Limpio
Fuente: (Ferreyros, separata S.O.S, 2011)
108
h) Identificacin de la calidad de aceite de las muestras de alta
concentracin identificadas en el paso g, segn el nmero
de serie del equipo y cdigo ISO:
limpio.
detalladas en la tabla:
109
i) Creacin de la tabla de metalurgia y composicin de metales
en componentes hidrulicos.
110
hace referencia para su respectivo anlisis, interpretacin y
seguimiento
111
4.2 PRUEBA DE HIPOTESIS
112
Tabla 4.9: Categorizacin de muestra de aceite - III
114
4.4 APORTES Y APLICACIONES DE LOS RESULTADOS
muestra la figura.
115
Para poder simplificar el anlisis y operacionalizacion de los datos se
116
4.4.1 PLANTILLA DATOS NUMERICOS ENTEROS
REDONDEO
MAXIMO VALOR; FUNCION MAX 28 NUMERO DE INTERVALOS 7.17005855 7
MINIMO VALOR; FUNCION MIN 0 AMPLITUD= 3.9051285 4
RANGO=MAX-MIN 28
CAMBIAR SI SE MODIFICAN DATOS LIMITES MAX Y MIN
TABLA N 4.2 AL PPM GRAFICO OJIVA
FRECUENCIA FRECUENCIAS ACUMULADAS POLIGONO
LI VI XI
f1 hi pi(%) FI HI PI(%) DATO ADICIONAL 0 0 0 0
0 4 2 46 0.63888889 63.8888889 46 0.63888889 63.8888889 2 46 4 63.889
4 8 6 16 0.22222222 22.2222222 62 0.86111111 86.1111111 6 16 8 86.111
8 12 10 5 0.06944444 6.94444444 67 0.93055556 93.0555556 10 5 12 93.056
12 16 14 2 0.02777778 2.77777778 69 0.95833333 95.8333333 14 2 16 95.833
16 20 18 0 0 0 69 0.95833333 95.8333333 18 0 20 95.833
20 24 22 0 0 0 69 0.95833333 95.8333333 22 0 24 95.833
24 28 26 3 0.04166667 4.16666667 72 1 100 26 3 28 100.000
TOTAL 72 1 100 30 0
FUENTE: DATOS DE INFORMES DE LABORATORIO SOS DE FERREYROS SA
Concentracion de Al en PPM
50
45
Concentracion numero de muestras
40
0 0
Numero de muestras
35 2 46
30 6 16
25 10 5
20 14 2
15 18 0
10 22 0
5 26 3
0 30 0
0 2 6 10 14 18 22 26 30
Concentracion de Al en
0 46 16 5 2 0 0 3 0
PPM
-
FIGURA N 4.16: Plantilla de Datos Numericos Enteros
Fuente: Elaboracin propia
117
4.4.2 PLANTILLA DATOS NUMERICOS DECIMALES
PVI
0.2541 1.2658 0.985 0.78467 0.542154 1.12452 1.23543 RANGO = MAX-MIN
0.68452 2.2354 0.8754 1.1224 0.584654 0.8975 0.68754 CANTIDAD DE INTERVALOS K= 1+3.322LOG10N
0.254154 0.2541 0.7548 1.87542 0.58745 0.98675 0.98768 N=NUMERO DE DATOS 56
0.56545 1.235 0.5475 0.96854 1.12543 0.689756 0.689574 AMPLITUD=RANGO /NUM DE INTERVALOS
0.856424 0.256 1.23654 0.68754 0.65897 1.114522 1.1124 L 1I=VLOR MIN
0.68545 1.35654 0.5632 0.65864 1.12464 1.87648 1.65876 LI 2 = LI+AMPLITUD
0.256984 1.2654 1.425 1.1145 0.65876 0.79854 1.365428 VI 1 = LI 1 + AMLITUD
0.26534 1.2547 1.26587 1.69425 0.65344 0.84657 0.98647 hi=
REDONDEO
MAXIMO VALOR; FUNCION MAX 2.2354 NUMERO DE INTERVALOS 6.80748063 7
MINIMO VALOR; FUNCION MIN 0.2541 AMPLITUD= 0.28304286 0.28305
RANGO=MAX-MIN 1.9813
CAMBIAR SI SE MODIFICAN DATOS LIMITES MAX Y MIN GRAFICO
TABLA N 4.2 PVI
FRECUENCIA FRECUENCIAS ACUMULADAS POLIGONO OJIVA ACUMULADOS %
LI VI XI
f1 hi pi(%) FI HI PI(%) DATO ADICIONAL 0.112575 0 0.2541 0
0.2541 0.53715 0.395625 6 0.10714286 10.7142857 6 0.10714286 10.7142857 0.395625 6 0.53715 10.7142857
0.53715 0.8202 0.678675 19 0.33928571 33.9285714 25 0.44642857 44.6428571 0.678675 19 0.8202 44.6428571
0.8202 1.10325 0.961725 9 0.16071429 16.0714286 34 0.60714286 60.7142857 0.961725 9 1.10325 60.7142857
1.10325 1.3863 1.244775 16 0.28571429 28.5714286 50 0.89285714 89.2857143 1.244775 16 1.3863 89.2857143
1.3863 1.66935 1.527825 2 0.03571429 3.57142857 52 0.92857143 92.8571429 1.527825 2 1.66935 92.8571429
1.66935 1.9524 1.810875 3 0.05357143 5.35714286 55 0.98214286 98.2142857 1.810875 3 1.9524 98.2142857
1.9524 2.23545 2.093925 1 0.01785714 1.78571429 56 1 100 2.093925 1 2.23545 100
TOTAL 56 1 100 2.376975 0
FUENTE: ARCHIVOS DE LABORATORIO SOS DE FERREYROS SA
GRAFICO 4.1 GRAFICO 4.1 GRAFICO 5 GRAFICO 5
GRAFICO HISTOGRAMA O POLIGONO SE UTIILIZA XI GRAFICO 4.1 : CLICK INSERTAR COLUMNAS, LA RIMERA
SELECCIONAR DATOS, DESDE 0 HASTA 0, CLIK EDITAR, SELEC 0.11 HASTA 2.37
GRAFICO 4.1 PVI CLICK ACEPTAR, CAMBIAR NOMBRE, CLICK EDITAR POLIGONO
ACEPTAR, AGREGAR "HISTOGRAMA", SELEC DESDE 0 HASTA 0, ACEAPTAR
20
AGREGAR TITULOS
NUMERO DE MUESTRAS
18
16
14
12 CLICK EN BARRA O LINEA PARA MODIFICAR ESTILOS
10
8 HISTOGRAMA
6 INTERPRETACION: ASIMETRICA POSITIVA A DERECHA , NEGATIVA A LA IZQ , SIMETRICA
4
2 POLIGONO DE
0 FRECUENCIAS
OJIVA GRAFICO 5
100
80
60
40
20 Series1
0
PVI
39 M4T00202 2683 683 2 0 214 5 7 32 2 6 1 0 2 0 723 0 5 948 2 4 13 28 147 2581 6.6 46 14/11 18/15 LIMPIO MONITOREO
119
CONCLUSIONES
Magnesio y el Zinc.
posible falla por alta contaminacin de Al, Cu, B, Fe, Na,Si y Mg en el sistema
120
pues es menos costoso reemplazar vlvulas, filtros y acoples que bombas
121
RECOMENDACIONES
problemas a tiempo.
muestras de aceite.
comportamiento
122
REFERENCIAS BIBLIOGRAFICAS
123
ANEXOS
124