Sei sulla pagina 1di 54

CATHODIC PROTECTION SYSTEM FOR STEEL PILING

BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03


KONDUR PROJECT

DATA :
Calculated Life Time of anodes (Y) 15.00
Aluminium Anode Consumption rate (Con) 3.500
Current Density used for bare steel in seawater (CDsw) 0.055
Current Density used for coated steel in seawater (assumed coating damage 50%) (CDswc) 0.030
Current Density used for bare steel in seabed (CDsb) 0.020
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Cswc = Protective current required in seawater coated = Dia x pi x Lsw x CDswc
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Nos = Number of piles
Ctot = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Structure DIA DIA Lsw Lsb Cswc Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)
A. Area Approach Trestle, Fire Pump Platform, Metering Platform & Turning Area
A.1 Jetty 1
Vertical Pile 36 0.9144 16.00 10.00 1.379 0.575 1.953 113.9 9 1026 ICS 1150 ASOTB 9 1035
Raker Pile 36 0.9144 16.00 12.00 1.379 0.689 2.068 120.7 20 2413 ICS 1250 ASOTB 20 2500
A.2 Jetty 6
Vertical Pile 36 0.9144 16.00 10.00 1.379 0.575 1.953 113.9 13 1481 ICS 1150 ASOTB 13 1495
Raker Pile 36 0.9144 16.00 12.00 1.379 0.689 2.068 120.7 36 4343 ICS 1250 ASOTB 36 4500
B. Loading Platform
B.1 Jetty 1
Vertical Pile 30 0.7620 19.00 23.00 1.365 1.101 2.466 143.8 11 1582 ICS 1450 ASOTB 11 1595
Raker Pile 30 0.7620 19.00 25.00 1.365 1.197 2.561 149.4 8 1195 ICS 1500 ASOTB 8 1200
B.2 Jetty 6
Vertical Pile 30 0.7620 19.00 23.00 1.365 1.101 2.466 143.8 14 2014 ICS 1450 ASOTB 14 1610
Raker Pile 30 0.7620 19.00 25.00 1.365 1.197 2.561 149.4 8 1195 ICS 1500 ASOTB 8 1000
C. Mooring Dolphin
C.1 Jetty 1
Raker Pile 36 0.9144 16.00 10.00 1.379 0.575 1.953 113.9 40 4558 ICS 1150 ASOTB 40 4600
C.2 Jetty 6
Raker Pile 36 0.9144 16.00 10.00 1.379 0.575 1.953 113.9 40 4558 ICS 1150 ASOTB 40 4600
D. Breasting Dolphin
D.1 Jetty 1
Raker Pile 36 0.9144 19.00 23.00 1.637 1.321 2.959 172.6 20 3452 ICS 1750 ASOTB 20 3500
D.2 Jetty 6
Raker Pile 36 0.9144 19.00 23.00 1.637 1.321 2.959 172.6 20 3452 ICS 1750 ASOTB 20 3500
E. Walkway Support
E.1 Jetty 1
Vertical Pile 36 0.9144 16.00 18.00 1.379 1.034 2.413 140.8 2 282 ICS 1450 ASOTB 2 290
E.2 Jetty 6
Vertical Pile 36 0.9144 16.00 18.00 1.379 1.034 2.413 140.8 2 282 ICS 1450 ASOTB 2 290

al, jetty,bs,nace,Psambu, 19/09/12


CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER BS 7361

DATA :
Calculated Life Time of anodes (Y) 20.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater - para 7.2.2.1 (CDsw) 0.070 A/Sq.m
Current Density used for bare steel in seabed - para 7.2.2.1 (CDsb) 0.020 A/Sq.m

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDswc
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required = Y x Con x Cp
Nos = Number of piles
Al-total = Total weight of Aluminium anode required = Al x Nos
Anode Type = Aluminium Stand Off To Body
No Al = Proposed number of Aluminium Anode
S'plied = Total Aluminium Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl S'plied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (pcs) (kg)

Steel Pile 50.000 ### 13.00 19.00 3.631 1.516 5.147 360.3 105 37830 ICS 1800 ASOTB 210 37800
Steel Pile 28.000 0.7112 13.00 19.00 2.033 0.849 2.882 201.8 80 16141 ICS 2050 ASOTB 80 16400

TOTAL 185 53970 290 54200

al-jetty,BS, 15/09/11
180
205
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
JETTY BOSOWA GRINDING PLANT - MERAK

DATA :
Calculated Life Time of anodes (Y) 15.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for coated steel in seawater (assumed 50% damage) (CDswc) 0.028 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lswc = Length of pile in seawater coated
Lsb = Length of pile in seabed
Cswc = Protective current required in seawater = Dia x pi x Lsw x CDswc
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Nos = Number of piles
Cp = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Structure DIA DIA Lsw Lsb Cswc Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

36.00 0.9144 15.00 15.00 1.185 0.862 2.047 119.4 103 12298 ICS 1200 ASOTB 103 12360
28.00 0.7112 15.00 15.00 0.922 0.670 1.592 92.9 68 6315 ICS 950 ASOTB 68 6460

al-jetty,bosowamerak, 12/10/12
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
Pulau Sambu

DATA :
Calculated Life Time of anodes (Y) 30.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Nos = Number of piles
Ctot = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)
JETTY 1
Trestle (Tegak) 36.00 0.9144 25.00 10.00 3.950 0.575 4.524 475.1 9 4276 ICS 2400 ASOTB 18 4320
Trestle (Miring) 36.00 0.9144 30.00 12.00 4.740 0.689 5.429 570.1 20 11402 ICS 1900 ASOTB 60 11400
Jetty (Tegak) 30.00 0.7620 39.00 15.00 5.135 0.718 5.853 614.6 11 6760 ICS 2050 ASOTB 33 6765
Jetty (Miring) 30.00 0.7620 47.00 18.00 6.188 0.862 7.050 740.3 8 5922 ICS 2500 ASOTB 24 6000
Mooring Dolphin 36.00 0.9144 23.00 10.00 3.634 0.575 4.208 441.9 40 17676 ICS 2250 ASOTB 80 18000
Breasting Dolphin 36.00 0.9144 40.00 15.00 6.320 0.862 7.182 754.1 20 15082 ICS 2500 ASOTB 60 15000
Walkway 36.00 0.9144 30.00 10.00 4.740 0.575 5.314 558.0 2 1116 ICS 1850 ASOTB 6 1110

Total 110 62233 281 62595

JETTY 6
Trestle (Tegak) 36.00 0.9144 25.00 10.00 3.950 0.575 4.524 475.1 9 4276 ICS 2400 ASOTB 18 4320
Trestle (Miring) 36.00 0.9144 30.00 12.00 4.740 0.689 5.429 570.1 20 11402 ICS 1900 ASOTB 60 11400
Jetty (Tegak) 30.00 0.7620 39.00 15.00 5.135 0.718 5.853 614.6 11 6760 ICS 2050 ASOTB 33 6765
Jetty (Miring) 30.00 0.7620 47.00 18.00 6.188 0.862 7.050 740.3 8 5922 ICS 2500 ASOTB 24 6000
Mooring Dolphin 36.00 0.9144 23.00 10.00 3.634 0.575 4.208 441.9 40 17676 ICS 2250 ASOTB 80 18000
Breasting Dolphin 36.00 0.9144 40.00 15.00 6.320 0.862 7.182 754.1 20 15082 ICS 2500 ASOTB 60 15000
Walkway 36.00 0.9144 30.00 10.00 4.740 0.575 5.314 558.0 2 1116 ICS 1850 ASOTB 6 1110

Total 110 62233 281 62595

al-jetty,p sambu, 11/10/12


CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
JETTY BOSOWA GRINDING PLANT - MERAK

DATA :
Calculated Life Time of anodes (Y) 15.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for coated steel in seawater (assumed 50% damage) (CDswc) 0.028 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lswc = Length of pile in seawater coated
Lsb = Length of pile in seabed
Cswc = Protective current required in seawater = Dia x pi x Lsw x CDswc
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Nos = Number of piles
Cp = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Structure DIA DIA Lsw Lsb Cswc Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

36.00 0.9144 15.00 15.00 1.185 0.862 2.047 119.4 103 12298 ICS 1200 ASOTB 103 12360
28.00 0.7112 15.00 15.00 0.922 0.670 1.592 92.9 68 6315 ICS 950 ASOTB 68 6460

Total 171 18612 171 18820

al-jetty,bosowamerak, 12/10/12
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
LCT JETTY

DATA :
Calculated Life Time of anodes (Y) 15.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.060 A/Sq.m
Current Density used for coated steel in seawater (assumed 50% damage) (CDswc) 0.030 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lswc = Length of pile in seawater coated
Lsb = Length of pile in seabed
Cswc = Protective current required in seawater coated = Dia x pi x Lsw x CDswc
Csb = Protective current required in seabed bare = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
Nos = Number of piles
Al-total = Total weight of Aluminium Anode required = Al x Nos
Anode Type = Aluminium Stand Off To Body
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure Piles DIA DIA Lsw Lsb Cswc Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
Number (inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

Ramp 1 - 12 24.00 0.6096 2.00 34.00 0.115 1.302 1.417 82.7 12 992 ICS 850 ASOTB 12 1020
Ramp 13 - 18 24.00 0.6096 4.00 36.00 0.230 1.379 1.609 93.8 6 563 ICS 950 ASOTB 6 570
Ramp 19 - 24 28.00 0.7112 6.00 34.00 0.402 1.519 1.921 112.1 6 673 ICS 1150 ASOTB 6 690
MD 2 25 - 28 28.00 0.7112 4.00 36.00 0.268 1.609 1.877 109.5 4 438 ICS 1100 ASOTB 4 440
BD 3 29 - 32 28.00 0.7112 8.00 36.00 0.536 1.609 2.145 125.1 4 500 ICS 1250 ASOTB 4 500
BD 2 33 - 36 28.00 0.7112 11.00 33.00 0.737 1.475 2.212 129.0 4 516 ICS 1300 ASOTB 4 520
BD 1 37 - 40 28.00 0.7112 13.00 35.00 0.871 1.564 2.435 142.1 4 568 ICS 1450 ASOTB 4 580
MD 1 41 - 44 28.00 0.7112 14.00 34.00 0.938 1.519 2.458 143.4 4 573 ICS 1450 ASOTB 4 580

Total 44 4824 44 4900

al-jetty,lct, 1/10/13
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
LIQUID JETTY

DATA :
Calculated Life Time of anodes (Y) 15.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.060 A/Sq.m
Current Density used for coated steel in seawater (assumed 50% damage) (CDswc) 0.030 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lswc = Length of pile in seawater coated
Lsb = Length of pile in seabed
Cswc = Protective current required in seawater coated = Dia x pi x Lsw x CDswc
Csb = Protective current required in seabed bare = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
Nos = Number of piles
Al-total = Total weight of Aluminium Anode required = Al x Nos
Anode Type = Aluminium Stand Off To Body
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure Piles DIA DIA Lsw Lsb Cswc Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
Number (inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

Trestle 1 -8 28.00 0.7112 1.00 35.00 0.067 1.564 1.631 95.1 8 761 ICS 950 ASOTB 8 760
Trestle 9 - 12 28.00 0.7112 4.00 36.00 0.268 1.609 1.877 109.5 4 438 ICS 1100 ASOTB 4 440
Trestle 13 - 18 28.00 0.7112 11.00 33.00 0.737 1.475 2.212 129.0 6 774 ICS 1300 ASOTB 6 780
Trestle 19 - 24 28.00 0.7112 16.00 32.00 1.072 1.430 2.502 146.0 6 876 ICS 1500 ASOTB 6 900
Platform 25 - 52 32.00 0.8128 17.00 27.00 1.302 1.379 2.681 156.4 28 4379 ICS 1600 ASOTB 28 4480
MD 4 53 - 59 28.00 0.7112 15.00 33.00 1.005 1.475 2.480 144.7 7 1013 ICS 1450 ASOTB 7 1015
CT 3B 60 - 61 24.00 0.6096 13.00 31.00 0.747 1.187 1.934 112.8 2 226 ICS 1150 ASOTB 2 230
MD 3 62 - 66 28.00 0.7112 9.00 35.00 0.603 1.564 2.167 126.4 5 632 ICS 1300 ASOTB 5 650
CT 2B 67 - 68 24.00 0.6096 11.00 33.00 0.632 1.264 1.896 110.6 2 221 ICS 1150 ASOTB 2 230
BD 2 69,72 - 78 36.00 0.9144 18.00 26.00 1.551 1.494 3.045 177.6 8 1421 ICS 1800 ASOTB 8 1440
BD 2 70,71,79 32.00 0.8128 18.00 26.00 1.379 1.328 2.707 157.9 3 474 ICS 1600 ASOTB 3 480
BD 1 81,82,88 32.00 0.8128 18.00 26.00 1.379 1.328 2.707 157.9 3 474 ICS 1600 ASOTB 3 480
BD 1 80,83-87, 36.00 0.9144 18.00 26.00 1.551 1.494 3.045 177.6 6 1066 ICS 1800 ASOTB 6 1080
BD 1 89,90 36.00 0.9144 18.00 26.00 1.551 1.494 3.045 177.6 2 355 ICS 1800 ASOTB 2 360
CT 2A 91 - 92 24.00 0.6096 17.00 31.00 0.977 1.187 2.164 126.2 2 252 ICS 1300 ASOTB 2 260
MD 2 93 - 98 28.00 0.7112 11.00 33.00 0.737 1.475 2.212 129.0 6 774 ICS 1300 ASOTB 6 780
CT 3A 99 - 100 24.00 0.6096 8.00 36.00 0.460 1.379 1.839 107.2 2 214 ICS 1100 ASOTB 2 220
MD 1 101 - 105 28.00 0.7112 8.00 36.00 0.536 1.609 2.145 125.1 5 626 ICS 1250 ASOTB 5 625

Total 105 14976 105 15210

al-jetty,liquid, 1/10/13
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
JETTY SOLID

DATA :
Calculated Life Time of anodes (Y) 15.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.060 A/Sq.m
Current Density used for coated steel in seawater (assumed 50% damage) (CDswc) 0.030 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lswc = Length of pile in seawater coated
Lsb = Length of pile in seabed
Cswc = Protective current required in seawater coated = Dia x pi x Lsw x CDswc
Csb = Protective current required in seabed bare = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
Nos = Number of piles
Al-total = Total weight of Aluminium Anode required = Al x Nos
Anode Type = Aluminium Stand Off To Body
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure Piles DIA DIA Lswc Lsb Cswc Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
Number (inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

Trestle 1 - 18 32.00 0.8128 18.00 26.00 1.379 1.328 2.707 157.9 18 2842 ICS 1600 ASOTB 18 2880
Trestle 19 - 27 28.00 0.7112 16.00 28.00 1.072 1.251 2.324 135.5 9 1220 ICS 1400 ASOTB 9 1260
Trestle 28 - 45 28.00 0.7112 12.00 28.00 0.804 1.251 2.056 119.9 18 2158 ICS 1200 ASOTB 18 2160
Trestle 46 - 57 28.00 0.7112 6.00 30.00 0.402 1.341 1.743 101.7 12 1220 ICS 1050 ASOTB 12 1260
Trestle 58 - 72 28.00 0.7112 3.00 27.00 0.201 1.207 1.408 82.1 15 1232 ICS 850 ASOTB 15 1275

Total 72 8672 72 8835

Jetty 1 32.00 0.8128 18.00 26.00 1.379 1.328 2.707 157.9 1 158 ICS 1600 ASOTB 1 160
Jetty 2 - 22 36.00 0.9144 18.00 26.00 1.551 1.494 3.045 177.6 21 3730 ICS 1800 ASOTB 21 3780
Jetty 23 - 53 32.00 0.8128 18.00 26.00 1.379 1.328 2.707 157.9 31 4895 ICS 1600 ASOTB 31 4960
Jetty 54 - 74 36.00 0.9144 18.00 26.00 1.551 1.494 3.045 177.6 21 3730 ICS 1800 ASOTB 21 3780
Jetty 75 - 131 32.00 0.8128 18.00 26.00 1.379 1.328 2.707 157.9 57 9000 ICS 1600 ASOTB 57 9120
Jetty 132 - 133 16.00 0.4064 18.00 22.00 0.689 0.562 1.251 73.0 2 146 ICS 750 ASOTB 2 150
Jetty 134 - 137 32.00 0.8128 18.00 26.00 1.379 1.328 2.707 157.9 4 632 ICS 1600 ASOTB 4 640

Total 137 22290 137 22590

al-jetty,solid, 1/10/13
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
TERMINAL BBM - KALIMANTAN

DATA :
Calculated Life Time of anodes (Y) 20.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for coated steel in seawater (assumed 50% damage) (CDswc) 0.028 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lswc = Length of pile in seawater coated
Lsb = Length of pile in seabed
Cswc = Protective current required in seawater = Dia x pi x Lsw x CDswc
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Nos = Number of piles
Cp = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Structure DIA DIA Lswc Lsb Cswc Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

Breasting Dolphin 24.00 0.6096 9.80 24.00 0.516 0.919 1.435 111.6 12 1340 ICS 1150 ASOTB 12 1380
Mooring Post 16.00 0.4064 3.00 24.00 0.105 0.613 0.718 55.9 8 447 ICS 600 ASOTB 8 480
Jetty Head 16.00 0.4064 9.80 24.00 0.344 0.613 0.957 74.4 14 1042 ICS 750 ASOTB 14 1050

Total 34 2829 34 2910

H-Beam 300 1.8000 9.80 24.00 0.485 0.864 1.349 104.9 3 315 ICS 1050 ASOTB 3 315

al-jetty,kalim 20, 26/11/12


CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
TERMINAL BBM - KALIMANTAN

DATA :
Calculated Life Time of anodes (Y) 10.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for coated steel in seawater (assumed 50% damage) (CDswc) 0.028 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lswc = Length of pile in seawater coated
Lsb = Length of pile in seabed
Cswc = Protective current required in seawater = Dia x pi x Lsw x CDswc
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Nos = Number of piles
Cp = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Structure DIA DIA Lswc Lsb Cswc Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

Breasting Dolphin 24.00 0.6096 9.80 24.00 0.516 0.919 1.435 55.8 12 670 ICS 600 ASOTB 12 720
Mooring Post 16.00 0.4064 3.00 24.00 0.105 0.613 0.718 27.9 8 223 ICS 300 ASOTB 8 240
Jetty Head 16.00 0.4064 9.80 24.00 0.344 0.613 0.957 37.2 14 521 ICS 400 ASOTB 14 560

Total 34 1414 34 1520

H-Beam 300 1.8000 9.80 24.00 0.485 0.864 1.349 52.5 3 157 ICS 550 ASOTB 3 165

al-jetty,kalim 10, 26/11/12


CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
CHANDRA ASRI BREASTING DOLPHIN AND MOORING DOLPHIN

DATA :
Calculated Life Time of anodes (Y) 10.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for coated steel in seawater (assumed 50% damage) (CDswc) 0.028 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lswc = Length of pile in seawater coated
Lsb = Length of pile in seabed
Cswc = Protective current required in seawater = Dia x pi x Lsw x CDswc
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Nos = Number of piles
Cp = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Structure DIA DIA Lswc Lsb Cswc Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

BD (E) = Existing Piles, (N) = New Piles


Steel Piles BD1 (E) 32.00 0.8128 21.00 10.00 1.475 0.511 1.985 77.2 13 1004 ICS 800 ASOTB 13 1040
Steel Piles BD1 (N) 28.00 0.7112 21.00 10.00 1.290 0.447 1.737 67.6 5 338 ICS 700 ASOTB 5 350
Steel Piles BD2 (E) 24.00 0.6096 21.50 11.00 1.132 0.421 1.554 60.4 9 544 ICS 650 ASOTB 9 585
Steel Piles BD2 (N) 28.00 0.7112 21.50 11.00 1.321 0.492 1.813 70.5 9 634 ICS 750 ASOTB 9 675
Steel Piles BD3 (N) 28.00 0.7112 16.00 14.00 0.983 0.626 1.609 62.6 11 688 ICS 650 ASOTB 11 715
Steel Piles BD4 (E) 32.00 0.8128 16.00 10.00 1.124 0.511 1.634 63.6 13 826 ICS 650 ASOTB 13 845
Steel Piles BD4 (N) 28.00 0.7112 16.00 10.00 0.983 0.447 1.430 55.6 5 278 ICS 600 ASOTB 5 300
Steel Piles BD5 (E) 24.00 0.6096 21.50 11.00 1.132 0.421 1.554 60.4 6 363 ICS 650 ASOTB 6 390
Steel Piles BD6 (E) 24.00 0.6096 21.50 11.00 1.132 0.421 1.554 60.4 6 363 ICS 650 ASOTB 6 390

MD
Steel Piles MD1 (E) 24.00 0.6096 16.00 13.00 0.843 0.498 1.341 52.1 8 417 ICS 550 ASOTB 8 440
Steel Piles MD1 (N) 28.00 0.7112 16.00 13.00 0.983 0.581 1.564 60.8 4 243 ICS 650 ASOTB 4 260
Steel Piles MD2 (E) 24.00 0.6096 17.00 12.00 0.895 0.460 1.355 52.7 8 422 ICS 550 ASOTB 8 440
Steel Piles MD2 (N) 28.00 0.7112 17.00 12.00 1.045 0.536 1.581 61.5 3 184 ICS 650 ASOTB 3 195
Steel Piles MD3 (E) 24.00 0.6096 15.00 12.00 0.790 0.460 1.250 48.6 8 389 ICS 500 ASOTB 8 400
Steel Piles MD3 (N) 28.00 0.7112 15.00 12.00 0.922 0.536 1.458 56.7 3 170 ICS 600 ASOTB 3 180
Steel Piles MD4 (E) 24.00 0.6096 16.00 12.00 0.843 0.460 1.302 50.6 8 405 ICS 550 ASOTB 8 440
Steel Piles MD4 (N) 28.00 0.7112 16.00 12.00 0.983 0.536 1.519 59.1 4 236 ICS 600 ASOTB 4 240
Steel Piles MD5 (E) 24.00 0.6096 10.00 12.00 0.527 0.460 0.986 38.4 8 307 ICS 400 ASOTB 8 320
Steel Piles MD5 (N) 28.00 0.7112 10.00 12.00 0.614 0.536 1.151 44.7 2 89 ICS 450 ASOTB 2 90

Abutment (E) 24.00 0.6096 5.00 22.00 0.263 0.843 1.106 43.0 6 258 ICS 450 ASOTB 6 270
TP1 (E) 24.00 0.6096 7.00 20.00 0.369 0.766 1.135 44.1 4 177 ICS 450 ASOTB 4 180
TP2 (E) 24.00 0.6096 8.00 19.00 0.421 0.728 1.149 44.7 4 179 ICS 450 ASOTB 4 180
PF1 (E) 24.00 0.6096 20.00 11.00 1.053 0.421 1.475 57.3 34 1950 ICS 600 ASOTB 34 2040
CP1 (E) 24.00 0.6096 16.00 13.00 0.843 0.498 1.341 52.1 4 209 ICS 550 ASOTB 4 220
CP2 (E) 24.00 0.6096 20.00 11.00 1.053 0.421 1.475 57.3 4 229 ICS 600 ASOTB 4 240
CP3 (E) 24.00 0.6096 16.00 11.00 0.843 0.421 1.264 49.2 4 197 ICS 500 ASOTB 4 200
CP4 (E) 24.00 0.6096 15.00 12.00 0.790 0.460 1.250 48.6 4 194 ICS 500 ASOTB 4 200
CP5 (E) 24.00 0.6096 15.00 12.00 0.790 0.460 1.250 48.6 4 194 ICS 500 ASOTB 4 200
CP6 (E) 24.00 0.6096 15.00 12.00 0.790 0.460 1.250 48.6 4 194 ICS 500 ASOTB 4 200
CP7 (E) 24.00 0.6096 15.00 12.00 0.790 0.460 1.250 48.6 4 194 ICS 500 ASOTB 4 200
CP8 (E) 24.00 0.6096 15.00 12.00 0.790 0.460 1.250 48.6 4 194 ICS 500 ASOTB 4 200
PF2 (E) 24.00 0.6096 16.00 11.00 0.843 0.421 1.264 49.2 8 393 ICS 500 ASOTB 8 400
TP1 (E) 24.00 0.6096 16.00 10.00 0.843 0.383 1.226 47.7 2 95 ICS 500 ASOTB 2 100
TP2 (E) 24.00 0.6096 16.00 10.00 0.843 0.383 1.226 47.7 2 95 ICS 500 ASOTB 2 100
TP3 (E) 24.00 0.6096 16.00 10.00 0.843 0.383 1.226 47.7 2 95 ICS 500 ASOTB 2 100
TOTAL 227 12749 227 13325

al-jetty,bs,nace,chandra,08/01/13
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
TERMINAL BBM - KALIMANTAN

DATA :
Calculated Life Time of anodes (Y)
Aluminium Anode Consumption rate (Con)
Current Density used for bare steel in seawater (CDsw)
Current Density used for coated steel in seawater (assumed 50% damage) (CDswc)
Current Density used for bare steel in seabed (CDsb)
Utilization Factor (U)

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lswc = Length of pile in seawater coated
Lsb = Length of pile in seabed
Cswc = Protective current required in seawater = Dia x pi x Lsw x CDs
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Nos = Number of piles
Cp = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Structure DIA DIA Lswc Lsb Cswc Csb Cp Al Nos Al-total Anode Typ
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg)

24.00 0.6096 8.00 16.00 0.421 0.613 1.034 80 246 19680 ICS

Total 246 19680

al-jetty,ks 5, 04/02/13
20.00 Years
3.500 kg/A.Y
0.055 A/Sq.m
0.0275 A/Sq.m
0.020 A/Sq.m
0.900

Dia x pi x Lsw x CDswc


Dia x pi x Lsb x CDsb
Csw + Csb

Y x Con x Ctotal : U

Anode Type NoAl S'pplied


(Pcs) (kg)

800 ASOTB 246 19680 80

246 19680
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
DERMAGA BAUBAU - KALIMANTAN

DATA :
Calculated Life Time of anodes (Y) 20.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Nos = Number of piles
Cp = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)
20 Years Life Time
20.00 0.5080 12.00 12.00 1.053 0.383 1.436 112 7 782 ICS 1150 ASOTB 7 805

al-jetty,baubau, 07/02/13
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
DERMAGA SURABAYA

DATA :
Calculated Life Time of anodes (Y) 20.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Nos = Number of piles
Cp = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Pile Number DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)
20 Years Life Time
A0,A1,A2 20.00 0.5080 0.00 15.00 0.000 0.479 0.479 37.2 3 112 ICS 400 ASOTB 3 120
A3,A4,A5 20.00 0.5080 0.00 20.50 0.000 0.654 0.654 50.9 3 153 ICS 550 ASOTB 3 165
A6 20.00 0.5080 0.50 20.00 0.044 0.638 0.682 53.1 1 53 ICS 550 ASOTB 1 55
A7 20.00 0.5080 1.00 19.50 0.088 0.622 0.710 55.2 1 55 ICS 550 ASOTB 1 55
A8 20.00 0.5080 1.50 19.00 0.132 0.606 0.738 57.4 1 57 ICS 600 ASOTB 1 60
A9,A10,A11 20.00 0.5080 2.00 18.50 0.176 0.590 0.766 59.6 3 179 ICS 600 ASOTB 3 180
A12 20.00 0.5080 2.06 18.44 0.181 0.589 0.769 59.8 1 60 ICS 600 ASOTB 1 60
A13 20.00 0.5080 2.13 18.38 0.187 0.587 0.774 60.2 1 60 ICS 650 ASOTB 1 65
A14 20.00 0.5080 2.19 18.31 0.192 0.584 0.777 60.4 1 60 ICS 650 ASOTB 1 65
A15 20.00 0.5080 2.25 18.25 0.197 0.583 0.780 60.7 1 61 ICS 650 ASOTB 1 65
A16 20.00 0.5080 2.31 18.19 0.203 0.581 0.783 60.9 1 61 ICS 650 ASOTB 1 65
A17 20.00 0.5080 2.38 18.13 0.209 0.579 0.788 61.3 1 61 ICS 650 ASOTB 1 65
A18 20.00 0.5080 2.44 18.06 0.214 0.576 0.791 61.5 1 61 ICS 650 ASOTB 1 65
A19 20.00 0.5080 2.50 18.00 0.219 0.575 0.794 61.8 1 62 ICS 650 ASOTB 1 65
A20 20.00 0.5080 2.58 17.92 0.226 0.572 0.798 62.1 1 62 ICS 650 ASOTB 1 65
A21 20.00 0.5080 2.67 17.83 0.234 0.569 0.803 62.5 1 62 ICS 650 ASOTB 1 65
A22 20.00 0.5080 2.75 17.75 0.241 0.567 0.808 62.8 1 63 ICS 650 ASOTB 1 65
A23 20.00 0.5080 2.83 17.67 0.248 0.564 0.812 63.2 1 63 ICS 650 ASOTB 1 65
A24 20.00 0.5080 3.00 17.50 0.263 0.559 0.822 63.9 1 64 ICS 650 ASOTB 1 65
A25 20.00 0.5080 3.08 17.42 0.270 0.556 0.826 64.3 1 64 ICS 650 ASOTB 1 65
A26 20.00 0.5080 3.17 17.33 0.278 0.553 0.831 64.7 1 65 ICS 650 ASOTB 1 65
A27 20.00 0.5080 3.25 17.25 0.285 0.551 0.836 65.0 1 65 ICS 650 ASOTB 1 65
A28 20.00 0.5080 3.33 17.17 0.292 0.548 0.840 65.4 1 65 ICS 700 ASOTB 1 70
A29 20.00 0.5080 3.42 17.09 0.300 0.545 0.846 65.8 1 66 ICS 700 ASOTB 1 70
A30 20.00 0.5080 3.50 17.00 0.307 0.543 0.850 66.1 1 66 ICS 700 ASOTB 1 70
A31 20.00 0.5080 3.55 16.95 0.312 0.541 0.853 66.3 1 66 ICS 700 ASOTB 1 70
A32 20.00 0.5080 3.60 16.90 0.316 0.539 0.855 66.5 1 67 ICS 700 ASOTB 1 70
A33 20.00 0.5080 3.65 16.85 0.320 0.538 0.858 66.7 1 67 ICS 700 ASOTB 1 70
A34 20.00 0.5080 3.70 16.80 0.325 0.536 0.861 67.0 1 67 ICS 700 ASOTB 1 70
A35 20.00 0.5080 3.75 16.75 0.329 0.535 0.864 67.2 1 67 ICS 700 ASOTB 1 70
A36 20.00 0.5080 3.80 16.70 0.334 0.533 0.867 67.4 1 67 ICS 700 ASOTB 1 70
A37/B1 20.00 0.5080 3.85 16.65 0.338 0.531 0.869 67.6 1 68 ICS 700 ASOTB 1 70
A38/B2 20.00 0.5080 3.90 16.60 0.342 0.530 0.872 67.8 1 68 ICS 700 ASOTB 1 70
A39/B3 20.00 0.5080 3.95 16.55 0.347 0.528 0.875 68.1 1 68 ICS 700 ASOTB 1 70
A40/B4 20.00 0.5080 4.00 16.50 0.351 0.527 0.878 68.3 1 68 ICS 700 ASOTB 1 70
A41/B5 20.00 0.5080 4.00 16.50 0.351 0.527 0.878 68.3 1 68 ICS 700 ASOTB 1 70
A42 - A57 20.00 0.5080 4.00 18.00 0.351 0.575 0.926 72.0 16 1152 ICS 750 ASOTB 16 1200
Total 58 58

al-jetty,sby, 07/02/13
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
DERMAGA PERTAMINA

DATA :
Calculated Life Time of anodes (Y) 10.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Nos = Number of piles
Cp = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)
20 Years Life Time
8.63 0.2191 15.00 15.00 0.568 0.206 0.774 30 284 8551 ICS 300 ASOTB 284 8520

al-jetty,pertamina, 11/03/13
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
DERMAGA PT PALAPA ENERGY, DESA SELANGKAU, KEC KALIORANG, KAB KUTAI TIMUR

DATA :
Calculated Life Time of anodes (Y) 30.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Nos = Number of piles
Cp = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

NO Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl Total S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (pcs) (pcs) (kg)

1 Trestle 32.00 0.8128 13.00 53.00 1.826 2.707 4.532 529 21 11104 ICS 2650 ASOTB 2 42 11130
2 Trestle 28.00 0.7112 8.50 54.50 1.045 2.435 3.480 406 41 16646 ICS 2030 ASOTB 2 82 16646
3 Trestle 24.00 0.6096 3.00 45.00 0.316 1.724 2.040 238 43 10232 ICS 2400 ASOTB 1 43 10320
4 Platform 40.00 1.0160 17.00 59.00 2.984 3.766 6.751 788 8 6301 ICS 2630 ASOTB 3 24 6312
5 Platform 40.00 1.0160 16.00 59.00 2.809 3.766 6.575 767 14 10740 ICS 2560 ASOTB 3 42 10752
6 BD1 48.00 1.2192 17.00 59.00 3.581 4.520 8.101 945 4 3780 ICS 3150 ASOTB 3 12 3780
7 BD1 40.00 1.0160 17.00 59.00 2.984 3.766 6.751 788 6 4726 ICS 2630 ASOTB 3 18 4734
8 BD2 48.00 1.2192 17.00 59.00 3.581 4.520 8.101 945 4 3780 ICS 3150 ASOTB 3 12 3780
9 BD2 40.00 1.0160 17.00 59.00 2.984 3.766 6.751 788 6 4726 ICS 2630 ASOTB 3 18 4734
10 MD1 40.00 1.0160 15.00 45.00 2.633 2.873 5.506 642 10 6424 ICS 2150 ASOTB 3 30 6450
11 MD4 40.00 1.0160 16.00 59.00 2.809 3.766 6.575 767 10 7671 ICS 2560 ASOTB 3 30 7680
12 MD2 40.00 1.0160 15.00 45.00 2.633 2.873 5.506 642 10 6424 ICS 2150 ASOTB 3 30 6450
13 MD3 40.00 1.0160 16.00 59.00 2.809 3.766 6.575 767 10 7671 ICS 2570 ASOTB 3 30 7710
14 CW1 36.00 0.9144 15.00 45.00 2.370 2.585 4.955 578 4 2313 ICS 2900 ASOTB 2 8 2320
15 CW2 36.00 0.9144 17.00 59.00 2.686 3.390 6.076 709 4 2835 ICS 2370 ASOTB 3 12 2844
16 Jetty 2&3 24.00 0.6096 7.00 58.00 0.737 2.222 2.959 345 18 6214 ICS 1730 ASOTB 2 36 6228
17 Jetty 2&3+WW 24.00 0.6096 9.00 58.00 0.948 2.222 3.170 370 34 12572 ICS 1850 ASOTB 2 68 12580
18 WW 24.00 0.6096 8.00 70.00 0.843 2.681 3.524 411 6 2467 ICS 2060 ASOTB 2 12 2472
19 MD1 24.00 0.6096 8.00 70.00 0.843 2.681 3.524 411 5 2056 ICS 2060 ASOTB 2 10 2060
20 MD3 24.00 0.6096 7.00 59.00 0.737 2.260 2.997 350 8 2797 ICS 1750 ASOTB 2 16 2800
21 Crew Jetty 18.00 0.4572 4.00 55.00 0.316 1.580 1.896 221 16 3539 ICS 1110 ASOTB 2 32 3552
22 Crew Jetty 20.00 0.5080 4.00 55.00 0.351 1.756 2.107 246 28 6882 ICS 1230 ASOTB 2 56 6888

Total 310 141898 663 142222

al-jetty,palapa, 04/04/13
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
BP BERAU - CASING SWI

DATA :
Calculated Life Time of anodes (Y) 20.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Nos = Number of piles
Cp = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

Casing 16.00 0.4064 5.85 0.00 0.411 0.000 0.411 32.0 3 96 ICS 320 ASOTB 3 96

al-jetty,casing, 09/07/13
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
JETTY BATULICIN

DATA :
Calculated Life Time of anodes (Y) 10.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required
Nos = Number of piles
Al-total = Total Weight of Aluminium Anode required
Anode Type = Aluminium Stand Off To Body
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)
JETTY 1
Jetty 24.00 0.6096 9.00 17.00 0.948 0.651 1.599 56.0 15 840 ICS 600 ASOTB 15 900
Breasting Dolphin 28.00 0.7112 9.00 17.00 1.106 0.760 1.866 65.3 20 1306 ICS 700 ASOTB 20 1400
Mooring Dolphin 24.00 0.6096 9.00 17.00 0.948 0.651 1.599 56.0 32 1791 ICS 600 ASOTB 32 1920
Catwalk 24.00 0.6096 9.00 17.00 0.948 0.651 1.599 56.0 4 224 ICS 600 ASOTB 4 240
Fender Piles 28.00 0.7112 9.00 7.00 1.106 0.313 1.419 49.7 5 248 ICS 500 ASOTB 5 250
Trestle (avg) 20.00 0.5080 5.00 18.00 0.439 0.575 1.013 35.5 34 1206 ICS 400 ASOTB 34 1360

Total 110 5615 110 6070

JETTY 2
Jetty 20.00 0.5080 6.00 20.00 0.527 0.638 1.165 40.8 15 612 ICS 450 ASOTB 15 675
20.00
Breasting Dolphin 0.5080 6.00 20.00 0.527 0.638 1.165 40.8 8 326 ICS 450 ASOTB 8 360
Mooring Dolphin 24.00 0.6096 6.00 20.00 0.632 0.766 1.398 48.9 8 391 ICS 500 ASOTB 8 400
Trestle (avg) 20.00 0.5080 3.00 21.00 0.263 0.670 0.934 32.7 15 490 ICS 350 ASOTB 15 525
Barrier (avg) 20.00 0.5080 3.00 17.00 0.263 0.543 0.806 28.2 15 423 ICS 300 ASOTB 15 450

Total 61 2243 61 2410

al-jetty,batulicin, 14/11/13
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
JETTY BATULICIN

DATA :
Calculated Life Time of anodes (Y)
Aluminium Anode Consumption rate (Con)
Current Density used for bare steel in seawater (CDsw)
Current Density used for bare steel in seabed (CDsb)

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required
Nos = Number of piles
Al-total = Total Weight of Aluminium Anode required
Anode Type = Aluminium Stand Off To Body
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg)

Loading Platform 24.00 0.6096 15.00 32.00 1.580 1.226 2.806 196.4 36 7070 ICS
Breasting Dolphin 28.00 0.7112 15.00 32.00 1.843 1.430 3.273 229.1 40 9165 ICS
Mooring Dolphin 28.00 0.7112 15.00 32.00 1.843 1.430 3.273 229.1 40 9165 ICS
Trestle (avg) 16.00 0.4064 7.50 20.00 0.527 0.511 1.037 72.6 66 4793 ICS
Abutment 16.00 0.4064 0.00 7.00 0.000 0.179 0.179 12.5 4 50 ICS
Catwalk 12.00 0.3048 15.00 17.00 0.790 0.326 1.116 78.1 43 3358 ICS

Total 229 33601

al-jetty,selago, 18/11/13
20.00 Years
3.500 kg/A.Y
0.055 A/Sq.m
0.020 A/Sq.m

Dia x pi x Lsw x CDsw


Dia x pi x Lsb x CDsb
Csw + Csb

Anode Type NoAl S'pplied


(Pcs) (kg)

2000 ASOTB 36 7200 200


2300 ASOTB 40 9200 230
2300 ASOTB 40 9200 230
750 ASOTB 66 4950 75
150 ASOTB 4 60 15
800 ASOTB 43 3440 80

229 34050
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER 8M00556-S07-Rev 0, 06 December 2013 and BS EN 13174
PT PMSK PETROLEUM PRODUCT JETTY

DATA :
Calculated Life Time of anodes para 4.17 (Y) 30.00 Years
Aluminium Anode Electrochemical Efficiency Para 7.5.5 2347 Ah/kg
Aluminium Anode Consumption rate (Con) 3.732 kg/A.Y
Current Density used for bare steel in seawaterTable A1 EN 13174 (maintenance value) (CDsw) 0.070 A/Sq.m
Current Density used for bare steel in seabed Table A2 EN 13174 (maintenance value) (CDsb) 0.020 A/Sq.m
Coating breakdown factors for driven piles Table A3 40 %
Deterioration rate for coatings high durability Table A3 for 30 years 0.5 % per year
Total coating damage factors (DF) 55 %
Utilization Factor (U) 0.850

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lswc = Length of pile in seawater coated
Lsbc = Length of pile in seabed coated
Cswc = Protective current required in seawater = Dia x pi x Lsw x CDswc x DF
Csbc = Protective current required in seabed = Dia x pi x Lsb x CDsbc x DF
Cp = Protective current required for each pile = Cswc + Csbc
Nos = Number of piles
Cp = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Straight Rod Core

Structure DIA DIA Lswc Lsbc Cswc Csbc Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

Breasting Dolphin
BD 1 40.00 1.0160 19.00 36.00 2.335 1.264 3.599 474.1 10 4741 ICS 1600 ASR 30 4800
BD 2 40.00 1.0160 21.00 36.00 2.581 1.264 3.845 506.5 10 5065 ICS 1700 ASR 30 5100
BD 3 40.00 1.0160 27.00 36.00 3.318 1.264 4.582 603.6 10 6036 ICS 2050 ASR 30 6150
BD 4 40.00 1.0160 29.00 36.00 3.564 1.264 4.828 636.0 10 6360 ICS 2150 ASR 30 6450
BD 5 40.00 1.0160 29.00 36.00 3.564 1.264 4.828 636.0 13 8268 ICS 2150 ASR 39 8385
BD 6 40.00 1.0160 28.00 36.00 3.441 1.264 4.705 619.8 13 8057 ICS 2100 ASR 39 8190
BD 7 40.00 1.0160 28.00 36.00 3.441 1.264 4.705 619.8 13 8057 ICS 2100 ASR 39 8190
BD 8 40.00 1.0160 27.00 36.00 3.318 1.264 4.582 603.6 13 7847 ICS 2050 ASR 39 7995

Mooring Dolphin
MD 1 36.00 0.9144 16.00 30.00 1.770 0.948 2.718 358.0 8 2864 ICS 1200 ASR 24 2880
MD 2 36.00 0.9144 27.00 30.00 2.986 0.948 3.934 518.3 8 4146 ICS 1750 ASR 24 4200

Platform
PF 1 32.00 0.8128 24.00 42.00 2.359 1.180 3.539 466.2 11 5128 ICS 1600 ASR 33 5280
PF 2 32.00 0.8128 29.00 32.00 2.851 0.899 3.750 494.0 34 16795 ICS 1650 ASR 102 16830
PF 3 32.00 0.8128 27.00 35.00 2.654 0.983 3.637 479.2 15 7188 ICS 1600 ASR 45 7200

Platform for Fire Pump Station


PF Fire Pump 28.00 0.7112 16.00 27.00 1.376 0.664 2.040 268.7 9 2419 ICS 1350 ASR 18 2430

TOTAL 177 92969 522 94080

al-jetty,bs,nace,puma,04/02/14
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
JETTY VOPAK

DATA :
Calculated Life Time of anodes (Y) 20.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required
Nos = Number of piles
Al-total = Total Weight of Aluminium Anode required
Anode Type = Aluminium Stand Off To Body
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

Dolphin 32.00 0.8128 9.00 20.00 1.264 1.021 2.285 160.0 1 160 ICS 1600 ASOTB 1 160

Total 1 160 1 160

al-jetty,vopak, 09/06/14
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
JETTY BATULICIN

DATA :
Calculated Life Time of anodes (Y) 10.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required
Nos = Number of piles
Al-total = Total Weight of Aluminium Anode required
Anode Type = Aluminium Stand Off To Body
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

JETTY 2
20.00 0.5080 6.00 18.00 0.527 0.575 1.101 38.5 67 2582 ICS 400 ASOTB 67 2680
24.00 0.6096 6.00 18.00 0.632 0.689 1.321 46.3 23 1064 ICS 500 ASOTB 23 1150

Total 90 3646 90 3830

al-jetty,batulicinrev1, 31/03/15
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
JETTY PLTU AMPANA

DATA :
Calculated Life Time of anodes (Y)
Aluminium Anode Consumption rate (Con)
Current Density used for bare steel in seawater (CDsw)
Current Density used for bare steel in seabed (CDsb)

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required
Nos = Number of piles
Al-total = Total Weight of Aluminium Anode required
Anode Type = Aluminium Stand Off To Body
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg)
No Pile Trestle
1 24.00 0.6096 5.00 4.10 0.527 0.157 0.684 47.9 1 48 ICS
2 24.00 0.6096 5.00 4.10 0.527 0.157 0.684 47.9 1 48 ICS
3 24.00 0.6096 5.00 4.10 0.527 0.157 0.684 47.9 1 48 ICS
4 24.00 0.6096 5.00 4.10 0.527 0.157 0.684 47.9 1 48 ICS
5 24.00 0.6096 5.00 4.10 0.527 0.157 0.684 47.9 1 48 ICS
6 24.00 0.6096 5.00 4.10 0.527 0.157 0.684 47.9 1 48 ICS
7 24.00 0.6096 5.00 4.10 0.527 0.157 0.684 47.9 1 48 ICS
8 24.00 0.6096 5.00 4.10 0.527 0.157 0.684 47.9 1 48 ICS
9 24.00 0.6096 5.00 4.10 0.527 0.157 0.684 47.9 1 48 ICS
10 24.00 0.6096 5.00 4.10 0.527 0.157 0.684 47.9 1 48 ICS
11 24.00 0.6096 12.00 4.10 1.264 0.157 1.421 99.5 1 99 ICS
12 24.00 0.6096 12.00 4.10 1.264 0.157 1.421 99.5 1 99 ICS
13 24.00 0.6096 12.00 4.10 1.264 0.157 1.421 99.5 1 99 ICS
14 24.00 0.6096 12.00 4.10 1.264 0.157 1.421 99.5 1 99 ICS
15 24.00 0.6096 12.00 5.10 1.264 0.195 1.459 102.2 1 102 ICS
16 24.00 0.6096 12.00 5.10 1.264 0.195 1.459 102.2 1 102 ICS
Jetty
17 28.00 0.7112 8.00 4.10 0.983 0.183 1.166 81.6 1 82 ICS
18 28.00 0.7112 7.00 4.10 0.860 0.183 1.043 73.0 1 73 ICS
19 28.00 0.7112 6.00 4.10 0.737 0.183 0.921 64.4 1 64 ICS
20 28.00 0.7112 5.00 4.10 0.614 0.183 0.798 55.8 1 56 ICS
21 28.00 0.7112 4.00 4.10 0.492 0.183 0.675 47.2 1 47 ICS
22 28.00 0.7112 9.00 4.10 1.106 0.183 1.289 90.2 1 90 ICS
23 28.00 0.7112 8.00 4.10 0.983 0.183 1.166 81.6 1 82 ICS
24 28.00 0.7112 7.00 4.10 0.860 0.183 1.043 73.0 1 73 ICS
25 28.00 0.7112 6.00 4.10 0.737 0.183 0.921 64.4 1 64 ICS
26 28.00 0.7112 5.00 4.10 0.614 0.183 0.798 55.8 1 56 ICS
27 28.00 0.7112 10.00 4.10 1.229 0.183 1.412 98.8 1 99 ICS
28 28.00 0.7112 10.00 4.10 1.229 0.183 1.412 98.8 1 99 ICS
29 28.00 0.7112 9.00 4.10 1.106 0.183 1.289 90.2 1 90 ICS
30 28.00 0.7112 8.00 4.10 0.983 0.183 1.166 81.6 1 82 ICS
31 28.00 0.7112 7.00 4.10 0.860 0.183 1.043 73.0 1 73 ICS
32 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
33 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
34 28.00 0.7112 12.00 4.10 1.475 0.183 1.658 116.0 1 116 ICS
35 28.00 0.7112 12.00 4.10 1.475 0.183 1.658 116.0 1 116 ICS
36 28.00 0.7112 12.00 4.10 1.475 0.183 1.658 116.0 1 116 ICS
37 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
38 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
39 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
40 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
41 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
42 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
43 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
44 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
45 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
46 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
47 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
48 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
49 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
50 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
51 28.00 0.7112 13.00 4.10 1.598 0.183 1.781 124.7 1 125 ICS
Breasting Dolphin 2
52 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
53 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
54 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
55 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
56 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
57 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
58 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
59 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
60 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
Catwalk 2
61 24.00 0.6096 3.00 4.80 0.316 0.184 0.500 35.0 1 35 ICS
62 24.00 0.6096 3.00 4.80 0.316 0.184 0.500 35.0 1 35 ICS
Mooring Dolphin 2
63 24.00 0.6096 3.00 4.80 0.316 0.184 0.500 35.0 1 35 ICS
64 24.00 0.6096 3.00 4.80 0.316 0.184 0.500 35.0 1 35 ICS
65 24.00 0.6096 3.00 4.80 0.316 0.184 0.500 35.0 1 35 ICS
66 24.00 0.6096 3.00 4.80 0.316 0.184 0.500 35.0 1 35 ICS
67 24.00 0.6096 3.00 4.80 0.316 0.184 0.500 35.0 1 35 ICS
Breasting Dolphin 1
68 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
69 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
70 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
71 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
72 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
73 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
74 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
75 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
76 28.00 0.7112 7.00 4.80 0.860 0.214 1.075 75.2 1 75 ICS
Catwalk 1
77 24.00 0.6096 3.00 4.80 0.316 0.184 0.500 35.0 1 35 ICS
78 24.00 0.6096 3.00 4.80 0.316 0.184 0.500 35.0 1 35 ICS
Mooring Dolphin 1
79 24.00 0.6096 3.00 4.80 0.316 0.184 0.500 35.0 1 35 ICS
80 24.00 0.6096 1.00 4.80 0.105 0.184 0.289 20.2 1 20 ICS
81 24.00 0.6096 1.00 4.80 0.105 0.184 0.289 20.2 1 20 ICS
82 24.00 0.6096 1.00 4.80 0.105 0.184 0.289 20.2 1 20 ICS
83 24.00 0.6096 1.00 4.80 0.105 0.184 0.289 20.2 1 20 ICS
648 364.7 Total 83 6463

al-jetty,ampana, 01/04/15
20.00 Years
3.500 kg/A.Y
0.055 A/Sq.m
0.020 A/Sq.m

Dia x pi x Lsw x CDsw


Dia x pi x Lsb x CDsb
Csw + Csb

Anode Type NoAl S'pplied


(Pcs) (kg)

500 ASOTB 1 50 160


500 ASOTB 1 50
500 ASOTB 1 50
500 ASOTB 1 50
500 ASOTB 1 50
500 ASOTB 1 50
500 ASOTB 1 50
500 ASOTB 1 50
500 ASOTB 1 50
500 ASOTB 1 50
1000 ASOTB 1 100
1000 ASOTB 1 100
1000 ASOTB 1 100
1000 ASOTB 1 100
1050 ASOTB 1 105
1050 ASOTB 1 105

850 ASOTB 1 85
750 ASOTB 1 75
650 ASOTB 1 65
600 ASOTB 1 60
500 ASOTB 1 50
950 ASOTB 1 95
850 ASOTB 1 85
750 ASOTB 1 75
650 ASOTB 1 65
600 ASOTB 1 60
1000 ASOTB 1 100
1000 ASOTB 1 100
950 ASOTB 1 95
850 ASOTB 1 85
750 ASOTB 1 75
1250 ASOTB 1 125
1250 ASOTB 1 125
1200 ASOTB 1 120
1200 ASOTB 1 120
1200 ASOTB 1 120
1250 ASOTB 1 125
1250 ASOTB 1 125
1250 ASOTB 1 125
1250 ASOTB 1 125
1250 ASOTB 1 125
1250 ASOTB 1 125
1250 ASOTB 1 125
1250 ASOTB 1 125
1250 ASOTB 1 125
1250 ASOTB 1 125
1250 ASOTB 1 125
1250 ASOTB 1 125
1250 ASOTB 1 125
1250 ASOTB 1 125
1250 ASOTB 1 125

800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80

350 ASOTB 1 35
350 ASOTB 1 35

350 ASOTB 1 35
350 ASOTB 1 35
350 ASOTB 1 35
350 ASOTB 1 35
350 ASOTB 1 35

800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80
800 ASOTB 1 80

350 ASOTB 1 35
350 ASOTB 1 35

350 ASOTB 1 35
210 ASOTB 1 35
210 ASOTB 1 35
210 ASOTB 1 35
210 ASOTB 1 35
6695
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
MARUNDA JETTY

DATA :
Calculated Life Time of anodes (Y) 25.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Total coating damage factors assumed (DF) 50 %

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lswc = Length of pile in seawater coated
Lsbc = Length of pile in seabed coated
Cswc = Protective current required in seawater = Dia x pi x Lsw x CDswc x DF
Csbc = Protective current required in seabed = Dia x pi x Lsb x CDsbc x DF
Cp = Protective current required for each pile = Cswc + Csbc
Al = Weight of Aluminium Anode required = Y x Con x Ctotal
Nos = Number of piles
Al-total = Total Weight of Aluminium Anode required = Nos x Al
Anode Type = Aluminium Straight Rod Core
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure DIA DIA Lswc Lsbc Cswc Csbc Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

40.00 1.0160 13.00 30.00 1.141 0.958 2.099 183.6 406 74554 ICS 1850 ASOTB 406 75110

TOTAL 406 74554 406 75110

al-jetty,bs,nace,marunda,02/04/15
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
Land Harbor DSLNG - Luwuk Sulawesi

DATA :
Calculated Life Time of anodes (Y) 20.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.120 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsb = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required
Nos = Number of piles
Al-total = Total Weight of Aluminium Anode required
Anode Type = Aluminium Stand Off To Body
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

Option 1
Tug Boat Berthing 30.00 0.7620 5.50 30.00 1.580 1.436 3.016 211.1 3 633 ICS 2150 ASOTB 3 645
Crew Boat Berthing 30.00 0.7620 5.50 15.00 1.580 0.718 2.298 160.9 3 483 ICS 1650 ASOTB 3 495
Mooring Boat Berthing 30.00 0.7620 5.50 15.00 1.580 0.718 2.298 160.9 3 483 ICS 1650 ASOTB 3 495
Total 9 1599 9 1635

Option 2
Tug Boat Berthing 30.00 0.7620 6.00 0.00 1.724 0.000 1.724 120.7 3 362 ICS 1250 ASOTB 3 375
Crew Boat Berthing 30.00 0.7620 6.00 0.00 1.724 0.000 1.724 120.7 3 362 ICS 1250 ASOTB 3 375
Mooring Boat Berthing 30.00 0.7620 6.00 0.00 1.724 0.000 1.724 120.7 3 362 ICS 1250 ASOTB 3 375
Total 9 1086 9 1125

al-jetty,luwuk, 10/04/15
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
PumpHouse Extension & Substructure of Fire Pump, Pertamina Dumai

DATA :
Calculated Life Time of anodes (Y) 20.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsbc = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required = Y x Con x Ctotal
Nos = Number of piles
Al-total = Total Weight of Aluminium Anode required = Nos x Al
Anode Type = Aluminium Straight Rod Core
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

28.00 0.7112 12.00 21.00 1.475 0.938 2.413 168.9 9 1520 ICS 1700 ASOTB 9 1530

TOTAL 9 1520 9 1530

al-jetty,bs,nace,dumai,12/05/15
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER DNV - RP - B401, April 2011
LNG Receiving Terminal Project Bojonegara, West Java,m Indonesia

DATA : Reference
Calculated Life Time of anodes (Y) 25 Years BLRT-FD-RPT-MJ-3018 para 5.3
Aluminium Anode Electrochemical Capacity 2500 Ah/kg DNV para 6,5,2
Aluminium Anode Consumption Rate (Con) 3.50 kg/A.Y 8760 : 2500
Current Density used for bare steel in seawater (CDsw) 0.070 A/Sq.m DNV table 10,2
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m DNV para 6,3,8
Anode Utilization Factor (U) 0.90 DNV table 10,8

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsbc = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
Nos = Number of piles
Al-total = Total Weight of Aluminium Anode required = Nos x Al
Anode Type = Aluminium Stand Off To Body (ASOTB)
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

42.00 1.0668 10.00 20.00 2.346 1.341 3.687 358.8 641 230009 ICS 3600 ASOTB 641 230760

TOTAL 641 230009 641 230760

al-jetty,bs,nace,dnv,lngbojonegara,20/08/15
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER DNV - RP - B401, April 2011

DATA : Reference
Calculated Life Time of anodes (Y) 20 Years
Aluminium Anode Electrochemical Capacity 2500 Ah/kg DNV para 6,5,2
Aluminium Anode Consumption Rate (Con) 3.50 kg/A.Y 8760 : 2500
Current Density used for bare steel in seawater (CDsw) 0.070 A/Sq.m DNV table 10,2
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m DNV para 6,3,8
Anode Utilization Factor (U) 0.90 DNV table 10,8

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsbc = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
Nos = Number of piles
Al-total = Total Weight of Aluminium Anode required = Nos x Al
Anode Type = Aluminium Stand Off To Body (ASOTB)
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

Trestle
T1 28.00 0.7112 8.00 13.00 1.251 0.581 1.832 142.7 2 285 ICS 1450 ASOTB 2 290
T2 28.00 0.7112 8.00 13.00 1.251 0.581 1.832 142.7 2 285 ICS 1450 ASOTB 2 290
T3 28.00 0.7112 6.00 15.00 0.938 0.670 1.609 125.3 2 251 ICS 1300 ASOTB 2 260
T4 28.00 0.7112 4.00 17.00 0.626 0.760 1.385 107.9 2 216 ICS 1100 ASOTB 2 220
T5 28.00 0.7112 3.00 18.00 0.469 0.804 1.274 99.2 2 198 ICS 1000 ASOTB 2 200
T6 28.00 0.7112 1.00 17.50 0.156 0.782 0.938 73.1 2 146 ICS 750 ASOTB 2 150
T7 28.00 0.7112 0.00 18.50 0.000 0.827 0.827 64.4 2 129 ICS 650 ASOTB 2 130
Platform
P1 40.00 1.0160 11.00 32.00 2.458 2.043 4.501 350.4 3 1051 ICS 1750 ASOTB 6 1050
P2 40.00 1.0160 11.00 32.00 2.458 2.043 4.501 350.4 3 1051 ICS 1750 ASOTB 6 1050
P3 40.00 1.0160 11.00 32.00 2.458 2.043 4.501 350.4 3 1051 ICS 1750 ASOTB 6 1050
P4 40.00 1.0160 11.00 26.25 2.458 1.676 4.133 321.9 3 966 ICS 1650 ASOTB 6 990
P5 40.00 1.0160 11.00 26.25 2.458 1.676 4.133 321.9 3 966 ICS 1650 ASOTB 6 990
P6 40.00 1.0160 11.00 26.25 2.458 1.676 4.133 321.9 3 966 ICS 1650 ASOTB 6 990
P7 40.00 1.0160 11.00 26.25 2.458 1.676 4.133 321.9 3 966 ICS 1650 ASOTB 6 990
P8 40.00 1.0160 8.50 23.00 1.899 1.468 3.367 262.2 3 787 ICS 1350 ASOTB 6 810
P9 40.00 1.0160 8.50 23.00 1.899 1.468 3.367 262.2 3 787 ICS 1350 ASOTB 6 810
P10 40.00 1.0160 8.50 23.00 1.899 1.468 3.367 262.2 3 787 ICS 1350 ASOTB 6 810
P11 40.00 1.0160 8.50 23.00 1.899 1.468 3.367 262.2 3 787 ICS 1350 ASOTB 6 810
P12 40.00 1.0160 8.50 23.00 1.899 1.468 3.367 262.2 3 787 ICS 1350 ASOTB 6 810
P13 40.00 1.0160 8.50 23.00 1.899 1.468 3.367 262.2 3 787 ICS 1350 ASOTB 6 810
P14 40.00 1.0160 7.50 19.75 1.676 1.261 2.937 228.7 3 686 ICS 2300 ASOTB 3 690
P15 40.00 1.0160 7.50 19.75 1.676 1.261 2.937 228.7 3 686 ICS 2300 ASOTB 3 690
P16 40.00 1.0160 7.50 19.75 1.676 1.261 2.937 228.7 3 686 ICS 2300 ASOTB 3 690
P17 40.00 1.0160 7.50 19.75 1.676 1.261 2.937 228.7 3 686 ICS 2300 ASOTB 3 690
P18 40.00 1.0160 7.50 19.75 1.676 1.261 2.937 228.7 3 686 ICS 2300 ASOTB 3 690
P19 40.00 1.0160 7.50 15.50 1.676 0.989 2.665 207.5 3 623 ICS 2100 ASOTB 3 630
P20 40.00 1.0160 7.50 15.50 1.676 0.989 2.665 207.5 3 623 ICS 2100 ASOTB 3 630
P21 40.00 1.0160 7.50 15.50 1.676 0.989 2.665 207.5 3 623 ICS 2100 ASOTB 3 630
MD
M1 36.00 0.9144 12.00 31.00 2.413 1.781 4.194 326.6 4 1306 ICS 1650 ASOTB 8 1320
TOTAL 81 19850 124 20170

al-jetty,bs,nace,dnv,penta,17/03/16
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
Dumai Jetty, China Harbour

DATA :
Calculated Life Time of anodes
Aluminium Anode Consumption rate
Current Density used for bare steel in seawater
Current Density used for bare steel in seabed
Anode Utilization Factor
NOTES AND FORMULAS :
CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsbc = Length of pile in seabed
Csw = Protective current required in seawater
Csb = Protective current required in seabed
Cp = Protective current required for each pile
Al = Weight of Aluminium Anode required
Nos = Number of piles
Al-total = Total Weight of Aluminium Anode required
Anode Type = Aluminium Stand Off To Body (ASOTB)
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos


(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs)

48.00 1.2192 20.00 42.00 4.213 3.217 7.431 289.0 61


60.00 1.5240 20.00 54.00 5.267 5.171 10.437 405.9 24
TOTAL 85

al-jetty,bs,nace,chinaharbour,28/11/16
(Y) 10.00 Years
(Con) 3.500 kg/A.Y
(CDsw) 0.055 A/Sq.m
(CDsb) 0.020 A/Sq.m
(U) 0.90

= Dia x pi x Lsw x CDsw


= Dia x pi x Lsb x CDsb
= Csw + Csb
= Y x Con x Ctotal : U

= Nos x Al

Al-total Anode Type NoAl S'pplied


(kg) (Pcs) (kg)

17627 ICS 2900 ASOTB 61 17690 290


9742 ICS 2035 ASOTB 48 9768 203.5
27369 109 27458
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
BOJONEGARA HEAVY CARGO TERMINAL - Alternative 1 coated condition

DATA :
Calculated Life Time of anodes
Aluminium Anode Consumption rate (8760 hr/yr:Current Capacity 2500 A hr/kg)
Current Density used for bare steel in seawater
Current Density used for coated steel in seawater (assumed 20% damage)
Current Density used for bare steel in seabed
Current Density used for coated steel in seabed (assumed 50% damage)
Utilization Factor

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lswc = Length of pile in seawater coated
Lsbc = Length of pile in seabed coated
Lsb = Length of pile in seabed bare
Cswc = Protective current required in seawater coated
Csbc = Protective current required in seabed coated
Csb = Protective current required in seabed bare
Cp = Protective current required for each pile
Nos = Number of piles
Cp = Total current required
Al = Weight of Aluminium Anode required
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Structure DIA DIA Lswc Lsbc Lsb Cswc Csbc Csb Cp Al Nos
(inch) (m) (m) (m) (m) (Amp) (Amp) (Amp) (Amp) (kg) (pcs)

48.00 1.2192 4.60 2.60 14.90 0.194 0.100 1.141 1.435 139.5 18

Total 18

Anode Life Time = (Al x U) / (Cp x Con) = 26.5 years

al-jetty,bojonegaraC, 30/01/17
(Y) 25.00 Years
(Con) 3.500 kg/A.Y
(CDsw) 0.055 A/Sq.m
(CDswc) 0.011 A/Sq.m
(CDsb) 0.020 A/Sq.m
(CDsb) 0.010 A/Sq.m
(U) 0.900

Yang ini juga dikirim

= Dia x pi x Lsw x CDswc


= Dia x pi x Lsb x CDsbc
= Dia x pi x Lsb x CDsb
= Cswc + Csbc+Csb

= Cp x Nos
= Y x Con x Ctotal : U

Al-total Anode Type NoAl S'pplied


(kg) (Pcs) (kg)

2511 ICS 1480 ASOBP 18 2664 148

2511 18 2664
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
BOJONEGARA HEAVY CARGO TERMINAL Alternative 2 - Bare condition

DATA :
Calculated Life Time of anodes (Y)
Aluminium Anode Consumption rate (8760 hr/yr:Current Capacity 2500 A hr/kg)(Con)
Current Density used for bare steel in seawater (CDsw)
Current Density used for bare steel in seabed (CDsb)
Utilization Factor (U)

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater bare
Lsb = Length of pile in seabed bare
Csw = Protective current required in seawater bare = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed bare = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw+Csb
Nos = Number of piles
Cp = Total current required = Cp x Nos
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied
Anode Type = Aluminium Stand Off To Body

Structure DIA DIA Lswc Lsb Csw Csb Cp Al Nos Al-total Anode Type
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg)

48.00 1.2192 4.60 17.50 0.969 1.341 2.310 224.5 18 4042 ICS

Total 18 4042

Anode Life Time = (Al x U) / (Cp x Con) = 25.1 years

al-jetty,bojonegaraB, 30/01/17
25.00 Years
3.500 kg/A.Y Yang ini yang dikirim
0.055 A/Sq.m
0.020 A/Sq.m
0.900

Dia x pi x Lsw x CDsw


Dia x pi x Lsb x CDsb

Y x Con x Ctotal : U

Anode Type NoAl S'pplied


(Pcs) (kg)

2250 ASOBP 18 4050 225

18 4050
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03

DATA :
Calculated Life Time of anodes (Y) 10 Years
Aluminium Anode Electrochemical Capacity 2500 Ah/kg
Aluminium Anode Consumption Rate (Con) 3.50 kg/A.Y 8760 : 2500
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Anode Utilization Factor (U) 0.90

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsbc = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
Nos = Number of piles
Al-total = Total Weight of Aluminium Anode required = Nos x Al
Anode Type = Aluminium Stand Off To Body (ASOTB)
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg)

Trestle 1/2
Axis 1 24.00 0.6096 1.50 38.50 0.158 1.475 1.633 64 10 636 ICS
Axis 2 24.00 0.6096 2.50 37.50 0.263 1.436 1.700 66 4 265 ICS
Axis 3 24.00 0.6096 2.50 37.50 0.263 1.436 1.700 66 4 265 ICS
Axis 4 24.00 0.6096 3.00 37.00 0.316 1.417 1.733 67 8 540 ICS
Axis 5 24.00 0.6096 2.50 37.50 0.263 1.436 1.700 66 4 265 ICS
Axis 6 24.00 0.6096 4.00 36.00 0.421 1.379 1.800 70 4 280 ICS
34 2250
Jetty
Axis A 24.00 0.6096 8.50 47.50 0.895 1.819 2.715 105.7 15 1585 ICS
Axis B 24.00 0.6096 8.00 48.00 0.843 1.839 2.681 104.4 23 2401 ICS
Axis C 24.00 0.6096 7.50 48.50 0.790 1.858 2.648 103.1 15 1546 ICS
Axis D 24.00 0.6096 6.00 50.00 0.632 1.915 2.547 99.2 4 397 ICS
Axis E 24.00 0.6096 5.00 51.00 0.527 1.953 2.480 96.6 4 386 ICS
61 6315
MD
MD 1/2 24.00 0.6096 8.50 47.50 0.895 1.819 2.715 105.7 16 1691 ICS

TOTAL 111 10256

al-jetty,bs,nace,dnv,holcimplmAl,06/06/16
8760 : 2500

Anode Type NoAl S'pplied


(Pcs) (kg)

650 ASOTB 10 650 65


700 ASOTB 4 280 70
700 ASOTB 4 280 70
700 ASOTB 8 560 70
700 ASOTB 4 280 70
700 ASOTB 4 280 70
34 2330

1100 ASOTB 15 1650 110


1050 ASOTB 23 2415 105
1050 ASOTB 15 1575 105
1000 ASOTB 4 400 100
1000 ASOTB 4 400 100
61 6440
1100 ASOTB 16 1760 110

111 10530
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03

DATA :
Calculated Life Time of anodes (Y) 10 Years
Zinc Anode Electrochemical Capacity 780 Ah/kg
Zinc Anode Consumption Rate (Con) 11.23 kg/A.Y 8760 : 780
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Anode Utilization Factor (U) 0.90

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsbc = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Zn-total = Weight of Zinc Anode required = Y x Con x Ctotal : U
Nos = Number of piles
Zn-total = Total Weight of Zinc Anode required = Nos x Zn
Anode Type = Zinc Stand Off To Body (ZSOTB)
No Al = Proposed number of Zinc Anode
S'pplied = Total Zinc Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Zn Nos Zn-total Anode Type
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg)

Trestle 1/2
Axis 1 24.00 0.6096 1.50 38.50 0.158 1.475 1.633 204 10 2037 ICS
Axis 2 24.00 0.6096 2.50 37.50 0.263 1.436 1.700 212 4 848 ICS
Axis 3 24.00 0.6096 2.50 37.50 0.263 1.436 1.700 212 4 848 ICS
Axis 4 24.00 0.6096 3.00 37.00 0.316 1.417 1.733 216 8 1730 ICS
Axis 5 24.00 0.6096 2.50 37.50 0.263 1.436 1.700 212 4 848 ICS
Axis 6 24.00 0.6096 4.00 36.00 0.421 1.379 1.800 225 4 899 ICS
34 7211
Jetty
Axis A 24.00 0.6096 8.50 47.50 0.895 1.819 2.715 338.8 15 5081 ICS
Axis B 24.00 0.6096 8.00 48.00 0.843 1.839 2.681 334.6 23 7695 ICS
Axis C 24.00 0.6096 7.50 48.50 0.790 1.858 2.648 330.4 15 4956 ICS
Axis D 24.00 0.6096 6.00 50.00 0.632 1.915 2.547 317.8 4 1271 ICS
Axis E 24.00 0.6096 5.00 51.00 0.527 1.953 2.480 309.5 4 1238 ICS
61 20242
MD
MD 1/2 24.00 0.6096 8.50 47.50 0.895 1.819 2.715 338.8 16 5420 ICS

TOTAL 111 32873

al-jetty,bs,nace,dnv,holcimplmZn,06/06/16
8760 : 780

Anode Type NoZn S'pplied


(Pcs) (kg)

2050 ASOTB 10 2050 205


2150 ASOTB 4 860 215
2150 ASOTB 4 860 215
2200 ASOTB 8 1760 220
2150 ASOTB 4 860 215
2250 ASOTB 4 900 225
34 7290

3400 ASOTB 15 5100 340


3350 ASOTB 23 7705 335
3350 ASOTB 15 5025 335
3200 ASOTB 4 1280 320
3100 ASOTB 4 1240 310
61 20350

3400 ASOTB 16 5440 340

111 33080
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03

DATA :
Calculated Life Time of anodes (Y) 10 Years
Aluminium Anode Electrochemical Capacity 2500 Ah/kg
Aluminium Anode Consumption Rate (Con) 3.50 kg/A.Y 8760 : 2500
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lsw = Length of pile in seawater
Lsbc = Length of pile in seabed
Csw = Protective current required in seawater = Dia x pi x Lsw x CDsw
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Csw + Csb
Al = Weight of Aluminium Anode required = Y x Con x Ctotal
Nos = Number of piles
Al-total = Total Weight of Aluminium Anode required = Nos x Al
Anode Type = Aluminium Stand Off To Body (ASOTB)
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

Structure DIA DIA Lsw Lsb Csw Csb Cp Al Nos Al-total Anode Type
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg)

10 Years Life Time


Steel Pile 20.00 0.5080 13.00 17.00 1.141 0.543 1.684 59 124 7316 ICS

124 7316
20 Years Life Time
Steel Pile 20.00 0.5080 13.00 17.00 1.141 0.543 1.684 118.0 124 14631 ICS

TOTAL 124 14631

al-jetty,bs,nace,dnv,mar10,09/06/16
20 Years

8760 : 2500

Anode Type NoAl S'pplied


(Pcs) (kg)

600 ASOTB 124 7440 60

124 7440

1200 ASOTB 124 14880 120

124 14880
PT FUKUDA TRIGUNA KONSTRUKSI
CATHODIC PROTECTION SYSTEM FOR STEEL PILING
BASIC CALCULATION FOR SACRIFICIAL SYSTEM AS PER NACE RP0176-03
JAWA 7 COAL FIRED POWER PLANT
12 JUNE 2017

DATA :
Calculated Life Time of anodes (Y) 25.00 Years
Aluminium Anode Consumption rate (Con) 3.500 kg/A.Y
Current Density used for bare steel in seawater (CDsw) 0.055 A/Sq.m
Current Density used for coated steel in seawater (assumed 50% damage) (CDswc) 0.0275 A/Sq.m
Current Density used for bare steel in seabed (CDsb) 0.020 A/Sq.m
Utilization Factor (U) 0.900

NOTES AND FORMULAS :


CD = Recommended Current Density of bare steel
DIA = Pile outside diameter
Lswc = Length of pile in seawater coated
Lsb = Length of pile in seabed bare
Cswc = Protective current required in seawater = Dia x pi x Lsw x CDswc
Csb = Protective current required in seabed = Dia x pi x Lsb x CDsb
Cp = Protective current required for each pile = Cswc + Csb
Al = Weight of Aluminium Anode required = Y x Con x Ctotal : U
Nos = Number of piles
Al Total = Total Aluminium Required = Al x Nos
Anode Type = Aluminium Stand Off Bent Pipe
No Al = Proposed number of Aluminium Anode
S'pplied = Total Aluminium Anode supplied

DIA DIA Lswc Lsb Cswc Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
Structure
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)

Y1 -a, Y1 -b 48.00 1.2192 8.76 43.00 0.923 3.294 4.217 410 2 819 ICS 2050 ASOBP 4 820
Y2 -a, Y2 -b 48.00 1.2192 8.76 43.00 0.923 3.294 4.217 410 2 819 ICS 2050 ASOBP 4 820
Y3 -a, Y3 -b 48.00 1.2192 8.76 43.00 0.923 3.294 4.217 410 2 819 ICS 2050 ASOBP 4 820
Y4 -a, Y4 -b 48.00 1.2192 8.76 43.00 0.923 3.294 4.217 410 2 819 ICS 2050 ASOBP 4 820
Y5 -a, Y5 -b 48.00 1.2192 8.76 43.00 0.923 3.294 4.217 410 2 819 ICS 2050 ASOBP 4 820
Y6 -a, Y6 -b 48.00 1.2192 8.76 42.00 0.923 3.217 4.140 402 2 804 ICS 2050 ASOBP 4 820
Y7 -a, Y7 -b 48.00 1.2192 8.76 42.00 0.923 3.217 4.140 402 2 804 ICS 2050 ASOBP 4 820
Y8 -a, Y8 -b 48.00 1.2192 9.26 41.00 0.975 3.141 4.116 400 2 800 ICS 2050 ASOBP 4 820
Y9 -a, Y9 -b 48.00 1.2192 9.76 41.00 1.028 3.141 4.169 405 2 810 ICS 2050 ASOBP 4 820
Y10-c, Y10-d, Y10-e 48.00 1.2192 9.76 42.00 1.028 3.217 4.245 412 3 1237 ICS 2050 ASOBP 6 1230

Y11-c, Y11-d, Y11-e 48.00 1.2192 9.76 43.00 1.028 3.294 4.322 420 3 1259 ICS 2200 ASOBP 6 1320
Y12-c, Y12-d, Y12-e 48.00 1.2192 9.76 43.00 1.028 3.294 4.322 420 3 1259 ICS 2200 ASOBP 6 1320
Y13-c, Y13-d, Y13-e 48.00 1.2192 9.76 45.00 1.028 3.447 4.475 435 3 1304 ICS 2200 ASOBP 6 1320
Y14 -a, Y14 -b 48.00 1.2192 10.26 47.00 1.081 3.600 4.681 455 2 909 ICS 1600 ASOBP 6 960
Y15 -a, Y15 -b 48.00 1.2192 10.26 49.00 1.081 3.754 4.834 470 2 939 ICS 1600 ASOBP 6 960
Y16 -a, Y16 -b 48.00 1.2192 10.76 53.00 1.133 4.060 5.193 505 2 1009 ICS 1750 ASOBP 6 1050
Y17 -a, Y17 -b 48.00 1.2192 10.26 55.00 1.081 4.213 5.294 514 2 1029 ICS 1750 ASOBP 6 1050
Y18 -a, Y18 -b 48.00 1.2192 10.26 55.00 1.081 4.213 5.294 514 2 1029 ICS 1750 ASOBP 6 1050
Y19 -a, Y19 -b 48.00 1.2192 10.26 55.00 1.081 4.213 5.294 514 2 1029 ICS 1750 ASOBP 6 1050
Y20 -a, Y20 -b 48.00 1.2192 10.26 55.00 1.081 4.213 5.294 514 2 1029 ICS 1750 ASOBP 6 1050

Y21 -a, Y21 -b 48.00 1.2192 10.26 56.00 1.081 4.290 5.371 522 2 1034 ICS 1750 ASOBP 6 1050
Y22 -a, Y22 -b 48.00 1.2192 10.76 60.00 1.133 4.596 5.730 557 2 1104 ICS 1900 ASOBP 6 1140
Y23 -a, Y23 -b 48.00 1.2192 9.76 63.00 1.028 4.826 5.854 569 2 1129 ICS 1900 ASOBP 6 1140
Y24 -a, Y24 -b 48.00 1.2192 9.76 64.00 1.028 4.903 5.931 576 2 1143 ICS 1950 ASOBP 6 1170
Y25 -a, Y25 -b 48.00 1.2192 9.76 64.00 1.028 4.903 5.931 576 2 1143 ICS 1950 ASOBP 6 1170
Y26 -a, Y26 -b 48.00 1.2192 9.76 64.00 1.028 4.903 5.931 576 2 1143 ICS 1950 ASOBP 6 1170
Y27 -a, Y27 -b 48.00 1.2192 10.76 62.00 1.133 4.749 5.883 572 2 1134 ICS 1950 ASOBP 6 1170
DIA DIA Lswc Lsb Cswc Csb Cp Al Nos Al-total Anode Type NoAl S'pplied
Structure
(inch) (m) (m) (m) (Amp) (Amp) (Amp) (kg) (pcs) (kg) (Pcs) (kg)
Y28 -a, Y28 -b 48.00 1.2192 10.76 61.00 1.133 4.673 5.806 564 2 1119 ICS 1900 ASOBP 6 1140
Y29 -a, Y29 -b 48.00 1.2192 10.26 58.00 1.081 4.443 5.524 537 2 1064 ICS 1800 ASOBP 6 1080
Y30 -a, Y30 -b 48.00 1.2192 10.76 55.00 1.133 4.213 5.347 519 2 1030 ICS 1750 ASOBP 6 1050

Y31 -a, Y31 -b 48.00 1.2192 10.76 52.00 1.133 3.983 5.117 497 2 985 ICS 1750 ASOBP 6 1050
Y32 -a, Y32 -b 48.00 1.2192 10.76 51.00 1.133 3.907 5.040 490 2 970 ICS 1750 ASOBP 6 1050
Y33 -a, Y33 -b 48.00 1.2192 10.76 51.00 1.133 3.907 5.040 490 2 970 ICS 1750 ASOBP 6 1050
Y34 -a, Y34 -b 48.00 1.2192 10.76 51.00 1.133 3.907 5.040 490 2 970 ICS 1750 ASOBP 6 1050
Y35 -a, Y35 -b 48.00 1.2192 10.76 51.00 1.133 3.907 5.040 490 2 970 ICS 1750 ASOBP 6 1050
Y36 -a, Y36 -b 48.00 1.2192 11.26 52.00 1.186 3.983 5.169 502 2 995 ICS 1750 ASOBP 6 1050
Y37 -a, Y37 -b 48.00 1.2192 11.76 53.00 1.239 4.060 5.299 515 2 1021 ICS 1750 ASOBP 6 1050
Y38 -a, Y38 -b 48.00 1.2192 11.26 54.00 1.186 4.137 5.323 517 2 1025 ICS 1750 ASOBP 6 1050
Y39 -a, Y39 -b 48.00 1.2192 11.26 56.00 1.186 4.290 5.476 532 2 1055 ICS 1800 ASOBP 6 1080
Y40 -a, Y40 -b 48.00 1.2192 11.26 56.00 1.186 4.290 5.476 532 2 1055 ICS 1800 ASOBP 6 1080

Y41 -a, Y41 -b 48.00 1.2192 11.26 56.00 1.186 4.290 5.476 532 2 1055 ICS 1800 ASOBP 6 1080
Y42 -a, Y42 -b 48.00 1.2192 11.26 54.00 1.186 4.137 5.323 517 2 1025 ICS 1750 ASOBP 6 1050
Y43 -a, Y43 -b 48.00 1.2192 11.26 54.00 1.186 4.137 5.323 517 2 1025 ICS 1750 ASOBP 6 1050
Y44 -a, Y44 -b 48.00 1.2192 10.76 55.00 1.133 4.213 5.347 519 2 1030 ICS 1800 ASOBP 6 1080
Y45 -a, Y45 -b 48.00 1.2192 10.76 56.00 1.133 4.290 5.423 527 2 1045 ICS 1800 ASOBP 6 1080
Y46 -a, Y46 -b 48.00 1.2192 10.26 57.00 1.081 4.366 5.447 529 2 1049 ICS 1800 ASOBP 6 1080
Y47 -a, Y47 -b 48.00 1.2192 10.26 57.00 1.081 4.366 5.447 529 2 1049 ICS 1800 ASOBP 6 1080
Y48 -a, Y48 -b 48.00 1.2192 10.26 58.00 1.081 4.443 5.524 537 2 1064 ICS 1800 ASOBP 6 1080
Y49 -a, Y49 -b 48.00 1.2192 10.26 58.00 1.081 4.443 5.524 537 2 1064 ICS 1800 ASOBP 6 1080
Y50-f, Y50-g, Y50-h 48.00 1.2192 10.26 58.00 1.081 4.443 5.524 537 3 1601 ICS 1800 ASOBP 9 1620

Y51-f, Y51-g, Y51-h 48.00 1.2192 10.76 56.00 1.133 4.290 5.423 527 3 1572 ICS 1800 ASOBP 9 1620
Y52-f, Y52-g, Y52-h 48.00 1.2192 10.76 54.00 1.133 4.137 5.270 512 3 1527 ICS 1800 ASOBP 9 1620
Y53-f, Y53-g, Y53-h 48.00 1.2192 10.76 53.00 1.133 4.060 5.193 505 3 1505 ICS 1800 ASOBP 9 1620

Y54-i, Y54-j, Y54-k 40.00 1.0160 10.76 52.00 0.944 3.320 4.264 414 3 1233 ICS 2100 ASOBP 6 1260
Y55-I, Y55-j, Y54-k 40.00 1.0160 11.26 51.00 0.988 3.256 4.244 412 3 1228 ICS 2100 ASOBP 6 1260

Y56-I, Y56-j, Y56-k,


Y56l, Y56-m, Y56-n,
40.00 1.0160 11.26 50.00 0.988 3.192 4.180 406 10 4051 ICS 2100 ASOBP 20 4200
Y57-I, Y57-j, Y57-k,
Y57-n

Y58-o, Y58-p, Y59-o,


Y59-p, Y60-o, Y60-p, 32.00 0.8128 7.76 27.00 0.545 1.379 1.924 187 8 1484 ICS 1900 ASOBP 8 1520
Y61-o, Y61-p
Y62-o, Y62-p, Y63-o,
Y63-p, Y64-o, Y64-p, 32.00 0.8128 8.76 26.00 0.615 1.328 1.943 188 8 1499 ICS 1900 ASOBP 8 1520
Y65-o, Y65-p

Total 146 65513 360 67480