Sei sulla pagina 1di 2

ProM Class-II Series

Modular Surge Protection Device

ProM Series: Protec M Class II & III Modular Surge


Protection Device

Key Features
Single Phase - 2P
Three Phase - 3P and 4P
High Energy Handling Capacity
Quick Response Time
Low let-thru Voltage
Compliant to IEC, VDE standards installation against the effects of direct lightning
and surge, and is installed on the main power supply
system, such as the service entrance, forming the
Application & Installation boundary of lightning protection zone 0A to LPZ1
within the Lightning Protection Zones Concept; A
The ProM series Class II arresters are designed for
typical application for surge arresters of Class II against
limiting surge in low-voltage installations. They also
the effect of surge caused by atmospheric discharge or
protect subsequently arranged installations and
switching transients is, at the sub-distribution board of
equipment against surge caused by power switching,
low-voltage installations forming the boundary from
ground potential rise, induced lightning electro-
LPZ 1 to LPZ2; And the application of surge arresters
magnetic pulses. Generally, a Class I surge protection
of Class III is for protection of sensitive equipments
device is used for protecting the low-voltage
against surge, installed at LPZ2 to LPZ3.

ProM Class II & III Series

Figures 1 ~ 4 show the suggested circuit diagrams for the installation of arresters. The earthing conductor
is to be connected to earth bus bar of the circuit being protected via the shortest possible path.

w w w. p r o t e c - p o w e r. c o m
Technical Data Sheet

Type ProM50 ProM40 ProM20


TNC TT TNC TT TNC TT
TNS L-N N-PE L-N N-PE L-N N-PE
Item TNS TNS
Nominal voltage UN 230 V ~ 50 HZ 230 V ~ 50 HZ 230 V ~ 50 HZ
Max. continuous operating UC 385 V ~ 255 V 385 V ~ 255 V 385 V ~ 255 V
voltage / 50 HZ / 50 HZ / 50 HZ / 50 HZ / 50 HZ / 50 HZ
Nominal discharge current ISN 30 KA 20 KA 10 KA
(8/20s)
Max. discharge current (8/20s) IMAX 50 KA 50 KA 40 KA 40 KA 20 KA 20 KA
Voltage protection level UP 1,8KV 1,2KV 1,8KV 1,2KV 1,0KV 1,2KV
Response time TA 25 ns 100 ns 25 ns 100ns 25 ns 100 ns
*Max. backup fuse 125AgK/gG - 125AgK/gG - 125AgK/gG -
Short-circuit withstand capabil- 25 KA / 50HZ - 25 KA/ - 25 KA/ -
ity with max. backup fuse 50HZ 50HZ
Operating temperature T -40C --- +80C -40C --- +80C -40C --- +80C
Isolating resistance Risol 1000MW 1000MW 1000MW
Degree of protection IP 20 IP 20 IP 20
Mounting on 35mm DIN-rail 35mm DIN-rail 35mm DIN-rail
Cross-sectional
areas 2,5 ~ 25mm2 2,5 ~ 25mm2 2,5 ~ 25mm2

2,5 ~ 35mm2 2,5 ~ 35mm2 2,5 ~ 35mm2

2,5 ~ 16mm2 2,5 ~ 16mm2 2,5 ~ 16mm2

Tightening torque of terminals 5 Nm 5 Nm 5 Nm


ProM Class II & III Series

Product Complied:
UL1449 3rd Edition, UL1283, CE Compliant and IEC ComplianU

Disclaimer: Protec Power Solutions Inc.


Protec Power Solutions Inc. shall not be liable for errors due to One Commerce Center, 1201 Orange St., #600 Wilmington
printing. The content of data sheets and products specifications New Castle, DE19899, U.S.A
may change as the company is always in the process of Ph: +1.302.669.9096
improving the products and marketing material. Email: sales@protec-power.com
w w w. p r o t e c - p o w e r. c o m

Potrebbero piacerti anche