Sei sulla pagina 1di 20

CoCoS-EDS

Engine Diagnostics System


Quick Reference

MAN Diesel
MAN Diesel A/S
Teglholmsgade 41
DK-2450 Copenhagen SV
Denmark
Telephone: +45 33 85 11 00
Telefax: +45 33 85 10 30
manbw@dk.manbw.com

Copyright MAN Diesel A/S. Reg. No. 39 66 13 14


Reproduction permitted provided source is given
Subject to modification in the interest of technical progress
3520-0005-00ppr Feb 2007

 (ofDiesel
MAN 20) - a member of the MAN Group
MAN Diesel

CoCoS-EDS Quick Reference

Contents
Engine Diagnostics System

What & How: Change to Chief or Crew Mode ..1


Make Performance Measurement ..2
Input / View Performance Data ..3
Perform Manual Diagnostics Evaluation ..4
View Diagnostic Details / History ..5
Store Line Recorder Data Dump ..6
Make Measurement from Line Recorder Zoom ..7
Calculate Fuel Oil Consumption ..8
View Load Diagram ..9
Monitor Parameters Over Time ..10
Copy Measurements to Excel ..11
Zoom with Mouse ..12
View / Set Display Attribute ..13
Print Pages to PDF..14

Special Input / Adjust Operating Hours ..15


Maintenance: Assign LCV, Density & Static Values ..16
CoCoS-EDS Quick Reference

View System Log-Errors & Warnings ..17


Set Up New Display Group ..18
Modify Existing Display Group ..19
Export / Import Measurements ..20

Crew: Training ..21

System System Overview: EDS & PMI ..22


Overviews Mode Indicators: On-line & Off-line ..23
Function & Keyboard Shortcuts ..24
Click Section to Open

 (of 20)
MAN Diesel

Change to Chief or Crew Mode 1


What & How

Change to Chief mode, by selecting:


System > Enter Password... in main menu
and typing Chief (not chief nor CHIEF)
Change back to standard user, i.e. Crew mode, by
selecting:
System > Passwords > Back in main menu.

Make Performance Measurement 2


A. Open PMI Analyzer if not already running
and make performance measurement based
on one of the following:
Recent PMI measurement In Crew
mode select:
Measurements > Read Pressure Curves
and click OK.
EDS automatically merges PMI data with
Trend data with same the time stamps.
Old PMI measurement Note time stamp
of old PMI measurement and select:
Monitoring > Line Recorder
or click tool button. Next zoom in on the
CoCoS-EDS Quick Reference

line recorder measurement consistent with


date and time of old PMI measurement (i.e.
drag mouse over it as in section 12) and
click the green tool button2.
Now go to Chief mode and select:
Measurements > Read Pressure Curves1
Click Read Old Curves, select PMI
measurement and click OK.
Click OK and Add to Current.

Verify Time stamps match and click OK.

 (of 20) 1 & 2


See Notes on next page
MAN Diesel

Without PMI measurement select:


Measurements >

What & How


Manual Input > Filtered Values
EDS now returns to the off-line mode to show the
measured values in the Standard Report.

i Note that the mode indicator has changed
colour to red in upper right corner of EDS. See
section 23.
B. Input off-line values from local gauges, such as
Pump/VIT index, VIT air pressure, ship speed, etc.,
in the report by clicking in the appropriate field and
keying in the correct value from the keyboard.


i Manually input values are marked with the
adjacent sign. If a manual value is deleted its
field will be reset to its original on-line value.
C. Store measurement by selecting:
Measurements > Store Measurements...,
Go to Chief mode and key in or set correct
date and/or operating hours for the meas-
urement and click Save followed by Close.
Notes:
1
EDS might prompt you to save an earlier mea-
CoCoS-EDS Quick Reference

surement. Often it can be ignored, i.e click No to


continue.
2
If the PMI measurement lies
outside the line recorder time
span, a compatible trend mea-
surement with similar time
stamp can be chosen by click-
ing on its grey indicator line
in the Trend > Time Plot view.
Thereafter, select the entry in
the dialogue that is opened
and click Load.

 (of 20)
MAN Diesel

Input / View Performance Data 3


What & How

A. Open Performance Report sheets:


Select Reports >
1 Performance_Sheets ....
If necessary:
Use % Box in Toolbar to resize dis-
play and/or click tool button when in
Chief mode.
Click tabs shown to view other pages
in report.
B. Switch to Off-line mode by double-click-
ing the mode indicator in the upper right Off-line
corner of EDS see 'Mode Indicator Table',
section 23.
EDS is now ready for manual input of measurement
data.
C. Select relevant field and input data:
Use Tab (or Shift Tab) keys to step forward (or
back) and type in text from keyboard.

i Switching back to on-line mode will not de-
lete nor save data. Store measurement to save it
see section 2 c.
CoCoS-EDS Quick Reference

Perform Manual Diagnostics Evaluation 4


A. Select:
Measurements > Measurements ...
and from the dialogue load the stored engine
performance measurement to be diagnosed.
See Note1 in section 2.
B. Select:
Measurements > Diagnostics.
EDS now evaluates the performance according to
the Instruction Book for the engine (Operation

 (of 20)
MAN Diesel

Chapter 7) and returns to the Diagnosis overview


to give:

What & How


diagnosis headlines if any to view details see
section 5B, or
status line prompt if no irregularities
are present.

View Diagnostic Details / History 5


A. View current on-line diagnosis (if any)
Select:
Diagnosis > Pending,
or double-click the on-line diagnosis
status indicators at bottom right
of screen see table opposite.

B. Right-click diagnosis of interest and select one of


the following in pop-up menu to:
acknowledge diagnosis, or
view diagnosis values (see Note1,
section 2), or
view Instruction Book advice for
CoCoS-EDS Quick Reference
restoring normal operation.
C. View past Diagnosis Select:
Diagnosis > Closed
for a bar view of diagnosis history.

Store Line Recorder Data Dump 6


A. Open the line recorder database:
System > Line Recorder Database
B. Click Add button to store new line
recorder dump.

 (of 20)
MAN Diesel


i Manual records are coloured green,
What & How

auto-matic records are black.


C. Click the new record to select it.
D. Click in comment field, key in a suitable
description and click Update to store and
OK to close.

Make Measurement from Line Recorder Zoom 7


A. Open line recorder database:
System > Line Recorder Database...
B. Select desired record/dump and click
Show.
C. Define measurement period by zooming
with mouse see section 12.
D. Click green tool button.

i EDS returns to Off-line mode to show standard
report giving average values for the zoomed pe-
riod. The start/stop times (period) are also stored.
E. Remember to store measurement if needed
see section 2C.
CoCoS-EDS Quick Reference

Calculate Fuel Oil Consumption 8


A. Make Performance Measurement see section 2.
B. Open Performance Report for above
measurement and click Consumption
link or relevant page tab. or

C. Input/verify fuel properties and flow meter/mass


counters.
D. Click Performance Sheet link to go
to Performance Report, page 1.
E. Remember to store measurement if needed
see section 2C.

 (of 20)
MAN Diesel

View Load Diagram 9

What & How


A. Go to the Trend view:
Trend > Time Plots or click tool button.
B. Do one or both of the following:
Right-click in the view to open the
Display Attributes dialogue and
check at least one of the check
boxes opposite, or
Mouse zoom to define the period of interest
see section 12.
C. View Load Diagram:
Monitoring > Load Diagram

i The dots shown in the Load Diagram are the
points selected in the Trend view.

Monitor Parameters Over Time 10


A. Go to Trends view:
Trend > Time Plots
B. Right-click in any operating value plot to open its
Display Attributes dialogue and set up its display.
As an example select Value option
CoCoS-EDS Quick Reference

opposite to see how the magnitude


deviates from the nominal value over
time or set Ambient Conditions as
shown to see equivalent ISO values.
C. Click tool button to reset (i.e. un-zoom)
display and view all trend entries.

Copy Measurements to Excel 11


A. Go to the Performance Table view:
Monitoring > Performance Tables
and select appropriate page tab.

 (of 20)
MAN Diesel

B. Right-click with mouse in any field to open Mea-


What & How

surement ... dialogue.


C. Use the mouse to select one or more individual
measurements:
Left-click to select single entry
Press Shift and left-click start and end
to select group of entries, or
Press Ctrl plus left-click to select non
adjacent entries.
D. Click Load button to display selected data
in the performance table.
E. Press Ctrl + C to copy.

i EDS copies all values in performance table to
clipboard in comma separated format (CSV).
F. Open an Excel sheet, press Ctrl + V or choose
Edit > Paste to paste copied data directly into the
sheet.

Zoom with Mouse 12


The Zoom function works with:
Line Recorder (Sideways & Up/Down)
CoCoS-EDS Quick Reference

Model Curves (Sideways & Up/Down)

Trends (Sideways & Up/Down)

Pressure Curves

Load Diagram (Sideways & Up/Down)

Bar Charts (Up/Down only)

Closed Diagnosis (Sideways only)

10 (of 20)
MAN Diesel

To zoom:

What & How


A. Click and hold down left mouse button
while moving mouse:
sideways for zooming time period, or
up or down for zooming magnitude.
B. Release mouse button to magnify (i.e. zoom in) on
defined area.
Click tool button to zoom out and restore
view to original size.

View / Set Display Attributes 13


In most views right-clicking the mouse within a
curve opens a Display Attributes dialogue box.
Examples of some of the attributes that may be
chosen are shown below, but may differ to suit the
particular view:
Monitor particular cylinders,
T/Cs or bearings, etc.

View time as running hours or


CoCoS-EDS Quick Reference

calendar time.

Set display limits.

Show Actual or ISO corrected


ambient conditions.

11 (of 20)
MAN Diesel

Show Actual values or deviation


What & How

from nominal.


i Trend data are often most relevant in devia-
tion from nominal (Act/Nom. Delta) value.

Print Pages to PDF 14


A. Select:
System > Print ...
B. Select a PDF Printer / Writer in the
'Print' dialogue.


i The Cute PDF Writer is supplied as standard
with EDS. It is freeware available from www.
cutepdf.com.
C. Click Print and select or create a folder for
the pdf file in the 'Save PDF File' dialogue.
Next type in a name for the file or accept the de-
fault file name 'EDS_ Printing pdf'.
D. Click Save to copy the current measure-
ment or report sheet that is displayed to the
CoCoS-EDS Quick Reference

specified folder ready to be archived or sent


as e-mail.

Continued >

12 (of 20)
MAN Diesel

Input / Adjust Engine Operating Hours 15

Special Maintenance
A. Change to Chief mode and open Operating
Hours dialogue:
Tools > Setup > Operating Hours...
B. Key in operating Hours plus minutes and
click OK.
C. Verify that the counter at the bottom left of
the screen shows the same operating hours.

Assign LCV, Density & Static Values 16


A. Change to Chief mode and open Static Values
dialogue:
Tools > Setup > Static Values....
B. Click '+' symbols to open main parameter lists at
top of dialogue. Double-click individual parame-
ters to select and add them to the static value list.
C. The appropriate static values may now be
keyed-in in the static value list at the bottom
of the dialogue. Press the Enter key at the
end of each entry.
D. Click OK to save your data and exit.
CoCoS-EDS Quick Reference
E. Click the Standard Report tool button and
verify that the correct static values have
been input in the Standard Report.

i Static values are marked by a Padlock
symbol.

View System Log Errors & Warnings 17


A. Check for errors and warnings:
Look for status line prompts at bottom
right-hand corner of screen, e.g.

13 (of 20)
MAN Diesel

B. Open system log:


Special Maintenance

Select Tools > System Log or double-


click status line error or warning prompt.
C. Copy and send details:
Make screen capture of system/warning
log by pressing Prt Scr key on keyboard
and pasting via clip board into word
processing or paint application.
Copy SYSTEM_ERROR.EDS file in EDS
directory.
Send above information to MBD if trouble-
shooting is necessary.
D. Acknowledge error and warnings:
Right-click within error/warning
details field and click pop-up but-
ton to acknowledge and close.

Set Up New Display Group 18


A. Select the view requiring a new
display group, e.g. Line Recorder,
Standard Report, Trend, etc.
CoCoS-EDS Quick Reference

B. Change to Chief mode and open


'Display Groups' dialogue:
Tools > Customise
> Display Groups
C. In Operating values field, double-
click one or more parameters of
interest in turn to highlight them and
click the Select button.
A new group is created at the bottom
of Display Groups field.

14 (of 20)
MAN Diesel

D. Click the Ready button to close the


dialogue and use the Page Up/Down

Special Maintenance
keys or tabs to select the last page
containing the new display group.
Modify Existing Display Group 19
A. To edit a Display Group:
Select (click) any group other than the
one to be modified.
B. Change to Chief mode and open Display
Group dialogue:
Tools > Customise > Display Groups...
C. Click the group to be modified in the Dis-
play group field and click the Edit button.
D. To add new parameters:
Double-click one or more items in turn in
the Operating value field above the 'Dis-
play group' and click the Add button.
The parameters are added to the appropri-
ate group in the Display group field.
E. To remove parameters:
Click to select a parameter in the Display
group field and click the Delete button.
CoCoS-EDS Quick Reference

Alternatively, to delete an entire group


click OK to return to the group selec-
tion view, click the group to be deleted
and then click the Delete button.
F. Click the Ready button to close the
dialogue and use the Page Up/Down
keys or tabs to select the page con-
taining the modified display group.
i EDS cannot change the active display group in-
dicated by a red page number. To change group you
must select another page.

15 (of 20)
MAN Diesel

Export / Import Measurements 20


Special Maintenance

A. Open Import/Export dialogue:


Measurements
> Import/Export Measurements ...
B. Open/Create archive:
Open existing Archive file, or
Create new one by clicking New button.
Key in relevant file name for archive and
click Save button.
i For easy location save the file in the root of
the CoCoS EDS directory.
C. Export/Import measurements:
Export single or all measurements from
EDS (left-field) to Archive (right-field) by
clicking buttons opposite
Import single or all measurements from
archive to EDS to Archive by clicking ...
D. Click OK button to finish.
CoCoS-EDS Quick Reference

Continued >

16 (of 20)
MAN Diesel

Crew Training 21

Crew Training
1. Operating values shown in standard report
User Access levels/password (Chief & Crew level)
Check limits (alarm limits), Display limits
Actual and nominal values (from model curves)
EDS filtering
On-line and off-line modes of EDS
Transfer on-line to off-line data (i.e. store measure-
ments)
2. Views
Engine Overview, Standard Report, Line Recorder
Characteristic Maps (Model Curves / Nominal Val-
ues)
Bar Charts, Load Diagram, Performance Curves
and Tables
Display groups, attributes, customising groups
3. Trend operation
Short trend, Long trend
Diagnostic trend & Manual trends (measurements)
4. Measurements
Line recorder zoom, filtered and non filtered values
Updating measurements with local readings and
PMI data
Storing and loading measurements
CoCoS-EDS Quick Reference

Printing measurements
Exporting to file, exporting to Excel
5. Adjusting values
Fuel oil properties and static values
Engine running hours
6. Line recorder measurement dumps
7. Diagnosis
Pending, closed
Triggering and acknowledgement
Measurement forced diagnostic calculation
8. Backup and restoration of data

17 (of 20)
MAN Diesel

22

System Connections CoCoS-EDS and PMI ECR PC


AMS Console
M/E
AMS PC(s) MOP A*
Software:
CoCoS-EDS
System Overview: CoCoS-EDS with PMI

PMI
TDC,
Trigg
To ECS1 ER ECR
Encoder
AlphaLub (if appl)
MOP B1
A/E #1
TDC,
Trigg
#2 MAN B&W Diesel A/S
#n
Converter BOX
AMS: Alarm Monitoring System M/E: Main Engine
1
ME engines only ECS: Engine Control System1 A/E: Auxiliary Engine
MOP: Main Operating Panel EDS: Engine Diagnostics System
2 ER: Engine Room PMI: Pressure Measurement Instrumentation
Optional MAN B&W A/E
ECR: Engine Control Room CoCoS: Computer Controlled Surveillance

18 (of 20)
System Overviews CoCoS-EDS Quick Reference
MAN Diesel

Mode Indicators: On-line & Off-line 23

System Overviews
Mode Indicator Mode indicator Stored File name
on right of EDS title bar on /Directory
double-click Non-Filtered Disk
> Filtered > Off-line
On-line

Non-Filtered Latest values: data acquisi-


tioned, calculated and static No CM.eds

Filtered Filtered values acquisitioned,


calculated and static accord- No
ing to EDS filter function

Off-line Manual Measurement from No


non filtered, filtered or blank

Cycle memory Manual measurement from No


measurement Line Recorder Zoom

Line recorder Manual measurement with No


measurement Zoom from Line Recorder
dump, i.e. from "emergency
stop"
Pressure Measurement updated from No PM.eds
measurement PMI database

Line recorder Static Line Recorder Dump Yes /Linerec


measurement View so-called "Base line" or
"Cycle memory" dump
Off-line

CoCoS-EDS Quick Reference


Measurement Measurement from Measure- Yes MT/
ment Trend database MT.eds
Diagnosis Auto generated measurements
measurement with operating values from a Yes diag.eds
Diagnosis

Short-Trend Auto generated measurements


entry with Short-Trend operating Yes /ST
values from Trend view
Long-Trend Auto generated measurements
entry with Long-Trend operating Yes /LT
values from Trend view

Reference Measurements for model


curve point curves generation loaded from Yes MC.eds
Characteristic Map view

19 (of 20)
MAN Diesel

Function & Keyboard Shortcuts 24

Ctrl Alt Shift


Esc Toggle Full Screen
F1 Acknowledge Emerg. Stop Analysis System Log
System Error =
Line Recorder Data-
base
F2 Pending Run Acknowledge View
Diagnosis Diagnostics Diagnosis Closed
Diagnosis

F3 Trend Line Store Measurements


Curves Recorder Measurement Database
Zoom
F4 Exit Close
Print Engine*
EDS*
F5 Arrange Arrange Cascade Windows
Windows Windows
Vertical Horizontal
F6 View Next Arrange Open
Grid Window Icons New View

F7 Filtered Values Off-line Values Non Filtered


Restore Values
Filtered Off-line
View Non-Filtered

F8 Engine Bar Standard Line


Overview Charts Report Recorder

F9 View Restore Read


Pressure Previous Pressure
Curves Zoom Curves
F10 Performance Model
Tables Curves
F11 Installation Performance
Report Report

F12 User's Setup Engine Channel Cal.* Setup


Guide Operating Hours* (1st data Acquisition Static
Protocol) Values
* <Chief> mode only
Example: Press Ctrl + F2 to Run Diagnostics on Performance Measurement

Copyright MAN Diesel A/S. Reg. No. 39 66 13 14


3520-0005-00ppr Feb 2007

Potrebbero piacerti anche