The FPD7024 Family FACPs can be used in you to use FPE-7024-ISO MUX bus isolator modules.
commercial, retail, and public building applications. The isolator modules prevent failure of the entire bus
They are listed by UL for central station, local, when there is a short on the bus.
auxiliary, and remote station systems.
The FACPs support four onboard initiating zones that Functions
can be expanded to eight using the FPC7034 Notification Appliance Circuits
Fourpoint expander. Each initiating zone supports Two Class A or Class B NACs provide regulated power
twowire and fourwire detectors configurable as to operate notification appliances. Each NAC can be
Class A or Class B loops. Each zone can support up to programmed to provide synchronized output for
20 twowire detectors, or any number of fourwire Wheelock, Gentex, or System Sensor notification
detectors depending on available power. Each FACP appliances. The available outputs are:
has a builtin digital fire alarm communicator Temporal Code 3
transmitter (DACT). California March
Enhance the FPD7024 conventional system features Steady
by adding an FPE-7039 or D7039 MUX expansion Pulsed
module. Adding a MUX expansion module to the FACP
User Interface
turns the conventional FACP into an addressable A viewing port shows the status lightemitting diodes
FACP. The MUX expansion module adds up to 247 (LEDs) and liquidcrystal display (LCD) while
addressable points to the base system. It also adds an maintaining system keypad security. For
additional 400 events to the history buffer for a total multilanguage applications, the status LEDs and
of 499 events. The module increases the number of keypad buttons are labeled with symbols. The display
programmable relay outputs from 19 to 59 and
expands system users to 100. The FPE-7039 allows
2 | FPD-7024 Family Fire alarm control panels
can be in US English, Latin-American Spanish, or dirty, the detector sends a CleanMe signal. For
Brazilian Portuguese. Unlocking the enclosure door detectors on an addressable loop, the detector sends
provides access to the system controls for: a dirty detector signal.
Silencing offnormal conditions
Bypassing zones
Accessories
The FPD7024 enclosure (P/N: F01U068852) has a
Resetting detectors
Testing
viewport for keypad messages while the enclosure
Programming door is locked. It also has space for additional
Other fire functions accessory modules and two 18 Ah batteries. The
Two additional keypads (FMR7033 LCD keypad and BATB40 or BATB-80 Battery box/enclosures
FMR-7036 Fire annunciator keypad) mimic the panels accommodate larger batteries or additional batteries.
builtin keypad. Wherever the FMR7033 is connected
to the system, it makes all the functions of the builtin Notice
keypad available. The FMR-7036 provides the status Notice!
LEDs and display (in any of the three available The panel can handle batteries up to 40 Ah. When
languages). The keylocked buttons provide access selecting batteries, ensure that the batteries can
only to reset, scroll, and silence functions. handle an initial charge current of at least 1.7 A.
B440 Conettix plugin cellular Power (nonresettable Auxiliary) 17 to 31 VRMS, unfiltered, 1.0 A
B441 Conettix plugin cellular Power (resettable Smoke)1 20.4 to 28.2 VDC nominal,
filtered, 1.0 A.
B442 Conettix plugin GPRS cellular
Power (Option Bus) 12 VDC nominal, 500 mA
B443 Conettix plugin HSPA+ cellular
Power (Notification Appliance Each NAC has 24 VRMS nominal,
B450 Conettix plugin communicator interface Circuit [NAC])2 unfiltered power with up to 2.5 A
D7035 Octal relay module capacity (but limited by the
panels overall 4.0 A capacity)
D7035B Octal relay module in box
Power (Optional Standby Two 12 V (in series), 7 Ah to
DX4010V2 USB/serial interface module Batteries) 40 Ah
D7050B6 Detector base Temperature (operating and +32F to +120F (0C to +49C)
storage)
Modules D7042 Multiplex eightinput remote module
Relays
Trademarks
All hardware/software product names used in this
document are likely to be registered trademarks and
must be treated accordingly.
Ordering information
Represented by: