E2C/E2C-H CSM_E2C_E2C-H_DS_E_9_2
Ordering Information
Sensors [Refer to Dimensions on page 18.]
Standard Models
*1. Values in parentheses are for the maximum sensing distances at 23C. * Self-diagnostic output, timer, and DIN Track mounting.
Heat-resistant Model
Sensor Amplifier Unit
Combination
Appearance Stable sensing area Model Model
M8 1.5 mm E2C-X1R5AH 3M E2C-JC4CH 2M
Shielded
M12 2 mm E2C-X2AH 3M E2C-JC4DH 2M
M18 5 mm E2C-X5AH 3M E2C-JC4EH 2M
Note: Characteristics will change if the cable length changes. Do not cut or extend the cable.
1
E2C/E2C-H
Connection Sockets A Socket is not provided with the Amplifier Unit. Order a Socket separately if required.
[Refer to Dimension on page 21.]
Name Model Applicable Amplifier Unit Remarks
Hold-down Clips (Order Separately)
E2C-GE4A
PYF08A PYC-A1
E2C-GF4A
Front Connection Sockets Sold as a set.
P2CF-08 E2C-AM4A
P2CF-11 E2C-AK4A
P3G-08 E2C-AM4A
---
P3GA-11 E2C-AK4A
Back Connection Sockets
E2C-GE4A
PY08
E2C-GF4A
Adapters An Adapter is not provided with the Amplifier Unit. Order an Adapter separately if required.
[Refer to Dimension on page 21.]
Name Model Applicable Amplifier Unit Remarks
Y92F-30
Embedded Adapters Y92F-70 E2C-AM4A/-AK4A ---
Y92F-71
For details on Mounting Brackets, Protective Covers, and Sputter Protective Covers, refer to Accessories on Y92@.
2
E2C/E2C-H
Ratings and Specifications
Standard Models
Sensors
Model E2C-CR8A/ E2C-X1A/
E2C-X1R5A E2C-X2A E2C-X5A E2C-X10A E2C-C20MA
Item -CR8B -C1A
Sensing distance
1.8 mm 2 mm 3 mm 5 mm 10 mm 18 mm 50 mm
(at 23C)
Ambient
Stable 0 to 0.8 mm 0 to 1 mm 0 to 1.5 mm 0 to 2 mm 0 to 5 mm 0 to 10 mm 0 to 20 mm
sensing temperature
area
At 0 to 40C 0 to 1.2 mm 0 to 1.5 mm 0 to 2 mm 0 to 2.5 mm 0 to 7 mm 0 to 15 mm 0 to 28 mm
Differential travel Refer to Ratings and Specifications on page 4 for Amplifier Unit specifications.
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 7.)
Standard sensing ob- Iron, 8 8 Iron, 12 12 Iron, 18 18 Iron, 30 30 Iron, 50 50
Iron, 5 5 1 mm
ject 1 mm 1 mm 1 mm 1 mm 1 mm
Response
1 kHz 800 Hz 350 Hz 100 Hz 50 Hz
frequency *1
Ambient
Operating/Storage: 25 to 70C (with no icing or condensation)
temperature range
Ambient
Operating/Storage: 35% to 95% (with no condensation)
humidity range
Temperature
15% max. of sensing distance at 23C in the temperature range of 25 to 70C
influence
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X and Y directions
Shock resistance Destruction: 500 m/s2 3 times each in X and Y directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Pre-wired Models
Connection method *2
High-frequency coaxial cable (Standard cable length: 3 m)
Weight
Approx. 40 g Approx. 45 g Approx. 50 g Approx. 60 g Approx. 140 g Approx. 270 g Approx. 300 g
(packed state)
Case Stainless steel Brass
Sensing
ABS resin
surface
Materi-
Cable Polyethylene
als
Clamping nut --- Brass, nickel-plated (except E2C-C1A)
Toothed
--- Brass, zinc-plated (except E2C-C1A)
washer
Accessories ---
*1. The minimum value when using the solid-state control output on the Amplifier Unit.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*2. Refer to 6 for cable lengths when combining Amplifier Units and Sensors.
The characteristic impedance of the high-frequency coaxial cable is 50 .
3
E2C/E2C-H
Amplifier Units
Model E2C-JC4A
E2C-GE4A E2C-GF4A E2C-AM4A E2C-AK4A
Item E2C-JC4AP
Current
25 mA max. 45 mA max. 50 mA max. 55 mA max.
consumption
Sensing distance 20% min. of rated sensing distance with 4-turn potenti-
20% to 100% of rated sensing distance with 4-turn potentiometer
adjustment range *2 ometer
Differential travel
Differential travel fixed (10% max. of sensing distance) 1% to 5% of rated sensing distance
adjustment range
Re- Solid-
(Refer to the response frequency of the Proximity Sensor.)
sponse state
time Relay --- 20 ms max.
Dielectric strength DC Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
AC Models: 1,500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz,
Destruction: 10 to 25 Hz, 2-mm double amplitude for 2 1.5-mm double amplitude Destruction: 10 to 25 Hz, 2-mm double amplitude for 2
Vibration resistance
hours each in X, Y, and Z directions for 2 hours each in X, Y, hours each in X, Y, and Z directions
and Z directions
*1. A full-wave rectification power supply of 24 VDC 10% (average value) can be used (except for the E2C-GE4@).
*2. The sensing distance range required to maintain performed is given for using the Amplifier Unit in combination with the Sensor.
*3. Internal relay: G2R-14 DC 12V
4
E2C/E2C-H
Model E2C-JC4A
E2C-GE4A E2C-GF4A E2C-AM4A E2C-AK4A
Item E2C-JC4AP
Heat-resistant Models
Sensors Amplifier Units
Model Item Model E2C-JC4CH E2C-JC4DH E2C-JC4EH
Item E2C-X1R5AH E2C-X2AH E2C-X5AH
Power supply
Ferrous metal (The sensing distance decreases with voltage *1
(operating voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Detectable object non-ferrous metal, refer to Engineering Data on page
7.) range)
Standard sensing Iron, 8 8 Iron, 12 12 Iron, 18 18 Current consump- 45 mA max.
object 1 mm 1 mm 1 mm tion
5
E2C/E2C-H
Cable Lengths for Sensor-Amplifier Unit Combinations
Standard Models
Sensor E2C- E2C-
E2C-CR8A E2C-CR8B E2C-X1A E2C-C1A E2C-X2A E2C-X5A E2C-X10A
Amplifier Units X1R5A C20MA
E2C-GE4A --- --- --- ---
Restricted to 3 m.
E2C-GF4A --- --- --- ---
1 to 3 m: Short cable length terminals *
E2C-JC4AP --- --- ---
3 to 5 m: Open cable length terminals *
E2C-JC4A Restricted to 3 m. --- --- ---
E2C-AM4A
0 to 5 m 0 to 10 m
Set cable length switch to desired position. * Set cable length switch to desired position. *
E2C-AK4A
Note: The standard cable length is 3 m. Models with 5-m or 10-m are manufactured upon order.
* Refer to page 14 for the operation of cable length switching.
Heat-resistant Models
Sensor
E2C-X1R5AH E2C-X2AH E2C-X5AH
Amplifier Units
E2C-JC4CH
E2C-JC4DH Set 3 m/5 m cable length switch to desired position.
E2C-JC4EH
Note: The standard cable length is 3 m. Models with 5-m are manufactured upon order.
Self-diagnostic Function
The self-diagnostic output transistor will turn ON in the following cases. (The output will turn ON for any of these conditions individually.)
(1) Sensor open circuit: Transistor will turn ON the instance there is an open circuit for the Sensor (including the cable).
Sensor Open Circuit Sensor Connected
Sensing distance:
Approx. 107%
Set distance: 100%
Approx. 97%
Present
Sensing object None
Time
Control output ON ON
(NO) Control output
OFF OFF
(NO) 0.3 s min. 0.3 s min.
Self-diagnostic ON ON
output
Self-diagnostic * *
OFF OFF
output
Detection indicator ON Detection indicator ON
Indicators
Indicators
(2) Detection: The output will turn ON if a sensing object is within 93% to 100% of the sensing distance continuously for 0.3 s or longer (e.g.,
for sensing object position offset).
(3) No detection: The output will turn ON if a sensing object is within 100% to 107% of the sensing distance continuously for 0.3 s or longer (e.g.,
when background is influencing detection).
Indicators
The detection indicator lights when a sensing object approaches the Detection Stability indicator
sensing distance to indicate that a sensing object has been detected. indicator (red) (green)
sensing area
Stable non-
The stability indicator lights when the sensing object approaches within
OFF ON
93% of the sensing distance or moves away from 107% of the sensing
distance to indicate a stable sensing or non-sensing condition. Set distance Approx. 1.07*
OFF
Set distance
ON
ON * When the E2C-X2A Sensor is used,
107% is 104% and 93% is 96%.
6
E2C/E2C-H
Engineering Data (Reference Value)
Sensing Area
E2C-CR8@
1.6
Distance X (mm)
Y
1.4 X
Sensing distance (variable):
0.16 to 0.8 mm
1.2
1.0
100%
0.8
0.6
50%
0.4
20%
0.2
3 2 1 0 1 2 3
Sensing Head Distance Y (mm)
E2C-X1A/-C1A E2C-X1R5A E2C-X2A
2.5 3
Distance X (mm)
1.6
Distance X (mm)
Distance X (mm)
0.8
1.0
0.6 50% 50%
50% 1
0.4
0.5
20% 20% 20%
0.2
0 0
3 2 1 0 1 2 Distance Y 4 3 2 1 0 1 2 3 4 Distance Y 6 4 2 0 2 4 6 Distance Y
E2C-C1A Sensing Head (mm) Sensing Head (mm) (mm)
Sensing Head
E2C-X1A Sensing Head
16
Distance X (mm)
Distance X (mm)
6 12
100%
100% 100% 20
5 10
4 8
3 6 50%
50% 50% 10
2 4
20% 20%
1 20%
2
0 0
10 8 6 4 2 0 2 4 6 8 10 Distance Y 0
15 10 5 0 5 10 15 Distance Y 20 15 10 5 0 5 10 15 20 Distance Y
Sensing Head (mm) (mm) Sensing Head (mm)
Sensing Head
Distance X (mm)
1
50% 3
50% 1 50%
2
0.5 20% 20% 20%
1
0 0 0
4 3 2 1 0 1 2 3 4 Distance Y 6 4 2 0 2 4 6 Distance Y 10 8 6 4 2 0 2 4 6 8 10 Distance Y
Sensing Head (mm) Sensing Head (mm) Sensing Head (mm)
7
E2C/E2C-H
d
d
1.4
t = 1 mm
X
1.2
1.0
0.8 Iron
0.6
0.4
0.2
0
2 4 6 8 10 12 14 16 18 20 22
Side length of sensing object: d (mm)
E2C-X1A/-C1A E2C-X1R5A E2C-X2A
1.6 2.5 3.5
Distance X (mm)
Distance X (mm)
Distance (mm)
d d d
d t = 1 mm d d t = 1 mm
1.4
t = 1 mm
X X X
3.0
2.0
1.2 2.5
Iron Iron
1.0 1.5 Iron
2.0
Stainless steel
Stainless steel (SUS304)
0.8 Stainless steel
(SUS304)
1.5 (SUS304)
Brass 1.0
0.6
Aluminum
Brass 1.0 Brass
0.4
0.5
0.5
0.2 Aluminum
Aluminum
0 2 4 6 8 10 12 14 16 18 20 0 2 4 6 8 10 12 14 16 18 20 0 2 4 6 8 10 12 14 16 18 20 22
Side length of sensing object: d (mm) Side length of sensing object: d (mm) Side length of sensing object: d (mm)
Distance X (mm)
Distance X (mm)
d d d
d t = 1 mm d
7 14
d
t = 1 mm t = 1 mm
X X 30 X
6 12
Iron 25
Iron
5 Iron
10
20
Stainless steel Stainless steel
4 Stainless steel 8 (SUS304) (SUS304)
(SUS304)
15
3 6
Brass Brass
Brass 10
2 4
Aluminum Aluminum
Aluminum
1 2 5
0 5 10 15 20 25 30 35 40 45 0 5 10 15 20 25 30 35 40 45 0 10 20 30 40 50 60 70 80 90 100110
Side length of sensing object: d (mm) Side length of sensing object: d (mm) Side length of sensing object: d (mm)
Distance X (mm)
Distance X (mm)
d d d
d t = 1 mm d d t = 1 mm
t = 1 mm
X 3 X 7 X
2
6
2.5
Iron Iron Iron
5
1.5
2
Stainless steel Stainless
(SUS304) 4 steel
Stainless
1.5 steel (SUS304)
1
(SUS304) 3
Brass Brass
1
Aluminum Brass 2 Aluminum
0.5 Aluminum
0.5 1
0 10 20 30 40 50 0 10 20 30 40 50 0 10 20 30 40 50
Side length of sensing object: d (mm) Side length of sensing object: d (mm) Side length of sensing object: d (mm)
8
E2C/E2C-H
I/O Circuit Diagrams
Output con-
E2C-GE4A * E2C-JC4A, E2C-JC4CH, E2C-JC4DH, E2C-JC4EH
figuration
12 to 24 VDC
13
Proximity 4.7 k Brown
Sensor 2.2 Output 12 to 24 VDC
main 9
circuit 100
mA 47 V Proximity
max. 100 mA 2.2
Black Output
NPN output 0V Sensor max.
14 main
circuit
47 V
* A voltage output can be used if the NO/NC switch on the Blue 0 V
E2C-GE4A is set to NC, but an approximately 60-ms
pulse will be generated when the power supply is turned
ON. An initial reset will thus be required.
If the E2C-GF4A (model for PNP output) is used, the initial
pulse will not occur.
E2C-JC4AP
Brown
Detection Stability
indicator 12 to 24 VDC
indicator
Load
(Red) (Green)
Black 100 mA
NPN output Proximity Output max.
Sensor
Self-diag- main
nosis Func- circuit ZD
tion 2.2 Blue
3.9 0V
ZD
Orange
Self-diagnostic output
50 mA max.
ZD : VZ = 40 V
E2C-GF4A
12 to 24 VDC
13
Proximity
PNP Output Sensor
47 V
main 2.2 Output
circuit
100 mA
9
4.7 k max.
0V
14
E2C-AM4A
12 to 24 VDC
47V
8
Both NPN 2.2 Output 1 (PNP)
and PNP Proximity 2
Sensor
outputs main
200 mA 2.2
max. Output 2 (NPN)
circuit 1
47V
0V
7
E2C-AK4A
9
E2C/E2C-H
Connections between Amplifier Unit and Sensor
8 7 6 5 6 5 4 3 Brown
Shield Line 10 to 30 VDC
4 Black
NPN open-
collector output
Blue
9 3 0V
Applicable Socket: 10 11 1 2 Applicable Socket: 7 8 1 2
P2CF-11 P2CF-08 PNP
0 V 12 to NPN Output
Note: Characteristics will change if the cable length
Tc Ta Tb
24 VDC output changes. Do not cut or extend the cable.
100 to 240 VAC Relay output
10
E2C/E2C-H
Load Connections
Model
E2C-JC4A, E2C-JC4@H
Load
DC load
Relay
Solenoid
Brown
Current-sink- Black
Load
ing load
Program-
Blue
mable
Controller
Sensor
Controller
Brown
12 to 24 VDC
Black 4.7 k
Voltage load +V
Model
E2C-GE4A
Load
DC load
Relay
Load
Solenoid 9
Programma-
ble Control-
ler 14 13
Sensor
Controller
12 to 24 V
9 +V
4.7 K W
Amplifier Unit 4.7K W
VV : 3V
To next stage
Voltage load Tr
(logic circuit)
4.7 K
0.0022
W
14 13
V (0 V)
IC: 20 mA max.
HFE: 50 mA max. Interface circuits Solid-state circuit
Tr
VCED: 30 V min.
11
E2C/E2C-H
Model
E2C-AK4A E2C-AM4A
Load
(12 to 24 V)
Ta Relay output 8
Load *
2 PNP Output Load
DC load 2
Amplifier Unit
Relay Amplifier Unit
Power NPN output IL
supply 1 Load
Solenoid DC or
(0 V)
200 mA max.
AC
Tc 7
1 * Use 40 V maximum when connecting the load to a separate
power supply.
Current-sinking (12 to 24 V)
Transistor/photocoupler output
load (photocou- IL 8
Load
Solid- pler) 5 50 mA max. 2 (PNP output) Load
state Programmable Amplifier Unit
Amplifier Unit NPN output IL
Controller 6
load 1 200 mA max.
Sensor (0 V)
7
Controller * For a current-sourcing load, connect to the negative side of the
* For a current-sourcing load, connect the PNP output.
transistor/photocoupler output.
The E2C-AK4A supports relay and transistor/photocoupler outputs, and the E2C-AM4A supports both NPN and PNP open-collector output. They can be connected to
a wide variety of load types and power polarities.
Operation
switch Operation switch
NO
Changes NC
NO/NC. Sensing object Present
Not present
Transistor output ON
(voltage output) OFF
ON
Detection indicator (red)
Sensing distance adjuster OFF
(4-turn potentiometer)
E2C-JC4A
Mounting
screw
OFF-delay Timing Chart
operation
terminals Operation switch NO
NC
Stability indicator Detection Sensing object Present
(green) indicator Not present
Output transistor 40 ms 40 ms
Sensing distance (red) Note: Terminals shorted: ON
OFF-delay operation OFF
adjuster enabled.
Operation Output transistor ON
switch Note: Terminals open: OFF
OFF-delay operation
Changes disabled. ON
NO/NC. Detection indicator (red) OFF
12
E2C/E2C-H
E2C-JC4AP
Mounting screw
Timing Chart
Cable length
compensation
terminals Operation mode selector NO
Detection NC
Stability indicator indicator Present
(green) (red) Sensing object
Sensing distance Not present
Output transistor
40 ms 40 ms
Timer switch: ON ON
adjuster Operation (OFF-delay operation
enabled.) OFF
Timer switch switch
Timer switch: OFF ON
Changes (OFF-delay operation
ON: 40 ms disabled.) OFF
NO/NC.
OFF: No delay Detection ON
indicator OFF
(red)
Hood mounting
Timing Chart
screw
Sensing object Present
Not present
NO Output transistor ON
OFF
Detection indicator ON
Sensing Detection OFF
distance indicator (red)
adjuster
Sensing object Present
Cable length Not present
compensation Mode selector
ON
switch NC Output transistor
OFF
Detection indicator ON
OFF
13
E2C/E2C-H
E2C-A@4A
Note: 1. Mutual Interference Prevention: When mounting Sensors with the same diameter and cable length in parallel, set the DIP switch to modes that differ by 1 m
in cable length. Specifications, however, may not be sufficiently met, so always check operation before actual application. This method cannot be used for
the E2C-C20MA.
2. When using the E2C-CR5B + E2C-AM4A (or AK4A), set all the pins on the Amplifier Unit DIP switch to the left.
14
E2C/E2C-H
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring Mounting
safety of persons either directly or indirectly. Do not use excessive force when tightening the nuts on the E2C-X
Do not use it for such purposes. and E2C-C20MA. A washer must be used with the nut.
B
A
Mutual Interference (Unit: mm)
Model Distance A B
E2C-CR8
E2C-X1A
20 15
E2C-C1A
E2C-X1R5A(H)
E2C-X2A(H) 30 20
E2C-X5A(H) 50 35
E2C-X10A 100 70
E2C-C20MA 300 200
Note: The above values are for a differential travel setting of 5%.
15
E2C/E2C-H
Mounting
Mounting the Amplifier Unit
E2C-JC4A E2C-A@4A
Lengthwise Mounting Using P2CF-11, P2CF-08
(1)Secure the Mounting Bracket with the enclosed M3 screws. When aligning the Amplifier Unit vertically with the Socket, consider
(2)Loosen the M2.6 cover screw and remove the cover. the space required for the hooks and allow a leeway of about 20 mm
(3)Slide the protrusion on the Amplifier Unit into the hole on the above and below the Amplifier Unit.
Mounting Bracket.
(4)Using the M3 mounting screw inside the Amplifier Unit, secure the
Amplifier Unit to the mounting base.
(5)Secure the cover to the case.
Hook
M2.6 cover screw Duct or
other object
P2CF-11
Panel P2CF-08 20
5 2
M3 Mounting Mounting Embedded in a Panel
screw
4 (1)When using the Y92F-30 Embedded Mounting Adapter, insert the
Amplifier Unit into a square hold in the panel, attach the Adapter
Mounting from the back and press in to reduce the gap with the panel. Then
3
Bracket
1 M3 screw (enclose) secure the Adapter with the screws.
Mounting
base
M3
M3 Mounting screw
O
N'T U
TO
16
E2C/E2C-H
Wiring
Self-diagnostic Output
When not using the self-diagnostic output, connect the orange wire to
0 V or cut it and wrap it with insulation tape so that it does not come
into contact with other terminals.
Miscellaneous
The sensor does not have a water-resistant structure. Do not use it
where it would be subjected to water or water vapor.
17
E2C/E2C-H
(Unit: mm)
Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Main Units
Sensor
E2C-CR8A/-CR8B
3.5 dia. *
15
3.5 dia.
E2C-X1A E2C-C1A
9.7 dia.
18
5.4 dia.
8 15 18
E2C-X1R5A E2C-X2A
E2C-X1R5AH* E2C-X2AH*
21 dia.
18
15 dia. 18
17 15
13 15 3
M8 1 2.5-dia. coaxial cable (50 ) with 1 2.5-dia. coaxial cable (50 ) with 1
4 conductor (Conductor cross M12 1 conductor (Conductor cross
section: 0.14 mm2), Standard 4 section: 0.14 mm2), Standard
length: 3 m (Material: Fluororesin)* length: 3 m (Material: Fluororesin)*
E2C-X5A E2C-X10A
E2C-X5AH*
42 dia. 40
29 dia. 37
30 36
24 27
2.5-dia. coaxial cable (50 ) with 5.5-dia. coaxial cable (50 ) with
M18 1 1 conductor (Conductor cross 1 conductor (Conductor cross
4 section: 0.14 mm2), Standard section: 0.5 mm2), Standard
length: 3 m (Material: Fluororesin)* length: 3 m
5
M30 1.5
E2C-C20MA 50
40 dia. 25 22
18
E2C/E2C-H
Amplifier Units
E2C-GE4A
E2C-GF4A Detection indicator (red)
1 5.4
20.7 35.5
Applicable Sockets
(Sold Separately)
27.2
PYF08A
PYF08
Hold-down Clip
PYC-A1
Applicable Sockets
(Sold Separately)
44.8 44.8
For E2C-AK4A (11-pin)
P2CF-11
P3GA-11
For E2C-AM4A (8-pin)
3.5 P2CF-08
6
P3G-08
Detection indicator (red) Stability indicator (green)
3.5
30
1
12
4 2 R1.55
Mounting Bracket Two, R1.65
3.3 dia. 6.2
3.3
430.2
(4) M3 11.5
11.8 0.1 3
R1.65 2 3.3 dia. 6.1+0.1
-0
40 0.1 3.1+0.1
-0
4-R1 13 0.1
58 3.5 0.1
3.3
5 400.2 * After completing adjustments, attach the caution label to prevent adjustment mistakes.
30 3.5
3.4 2
12
6 3
5.5
14
2.5 43
10 27
60 35
Mounting Bracket (removable)*2
*1. After completing adjustments, attach the caution label to prevent adjustment mistakes.
*2. Not required when mounting to DIN Track.
*3: 4.5-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.2 mm), Standard length: 2 m
19
E2C/E2C-H
Mounting Bracket
3
30 3.5
5.5
12
6 27
35
14
2.5 10 43
60
*1. After completing adjustments, attach the caution label to prevent adjustment mistakes
*2. Not required when mounting to DIN Track.
*3. 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter:
1.2 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
20
E2C/E2C-H
3.2 10 3.2 10
4.2 4.2
21 22
4 1
8 5
72 max. 35.4
590.3
12 9
4
14 13
150.2
6
23 max. Note: Track mounting is also
16.5 possible.
30 max.
P2CF-08
Eight, M3.5 7.5
Sems screws
Terminal Arrangement Mounting Hole Dimensions
7.8 3 4.5
and Internal Connections
(Top View) Two, 4.5-dia. or M4
holes
6 5 4 3
Two, 4.5-dia.
holes Note: Track mounting is also
possible.
7 8 1 2
4 50 max.
20.3 max.
P2CF-11
Eleven, M3.5 7.5 Terminal Arrangement and
Sems screws
Mounting Hole Dimensions
7.8 3 4.5 Internal Connections
Two, 4.5-dia.
(Top View) mounting holes
8 7 6 5
4
70 max. 35.4 400.2
Two, 4.5-dia.
holes
Note: Track mounting is also
9 3 possible.
10 11 1 2
4 50 max. 31.2 max.
21
E2C/E2C-H
2 1 8 7
45 17
4.9
P3GA-11
27 dia. Terminal Arrangement and
Internal Connections
(Bottom View)
5 6 7 8
45 25.6 4
3 9
2 1 11 10
45
4.5 16.3 6.2
PY08
Terminal Arrangement and Mounting Holes and PCB
Internal Connections Cutout Dimensions
Eight 3-dia. 1.2 ellipses (Bottom View) 13.2
1 4
5.8
25.5 max.
4.1
29.5 max. 5 8
25.80.2
12.65
9 12 6.35
2.7 7.7 2.6 6.4
13 14
21.4+0.2
0 4.2 Eight 1.3-dia. holes
20 max. 24 max.
22
E2C/E2C-H
58 45+0.5
0
Y92F-70
Panel
Mounting Hole Dimensions
Adapter mounting holes: Two, 4.5-dia.
P3G-08 Back-
mounting Socket R: 0.5 max.
52 to 53
88 450.15 65 to 66 760.2
Y92F-71
Panel
56 Mounting Hole Dimensions
P3G-08 Back-
mounting Socket R: 0.5 max. 45+0.5
0
58 450.2 68 55+0.5
0
23
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omrons exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omrons sole obligation hereunder shall be, at
Omrons election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyers application or use of the Product. At Buyers request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the users programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omrons test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omrons Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omrons representative at
any time to confirm actual specifications of purchased Product.
2015.8
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2015 All Right Reserved.