Sei sulla pagina 1di 4

EQUIPMENT

Parameters Values
Heads To 100 to 1,790ft
Flows To 200 to 1,040gpm
Max Power 200
Temp Range -200 to 650F
Number of Stages 1.0
Max Case Working Pressure 1,440 psi
Max Suction Pressure 500psi (36kg/cm)
Differential Head 1,790 ft
Standard Delivery 8 Weeks
The Sundyne LMV-313 is an
integrally geared centrifugal ISO 13709, Speed Range 5,802 to 12,234rpm-60Hz
API 610, 10th Edition OH6 pump.

Jereh International

ANSI series Mud Gate Valves


ANSI series mud gate valves conform to standard flange dimension and
pressure requirements for ANSI classes 400,600,900 and 1500, except
for 4" class 1,500 mud gate valve. Such gate valve is designed with
double acting threaded stem and gate, also using same rising stem
design as 4" 3,000psi API gate valve.

From http://www.jereh-oilfield.com/english/products/Mud-Gate-
Valve.htm.

SENSING DEVICE
1. Pressure Sensing Device (HPR01500PHNSNAAA25)

Honeywell Pressure Switches are durable, reliable electromechanical


gauge pressure on/off switches that are available with either single
pole single throw (SPST) normally open or normally closed circuitry, or
single pole double throw (SPDT) circuitry. Their IP67 environmental
sealing and high proof pressure and burst pressure ratings allow for use
in many rugged applications that require the making or breaking of an
electrical connection in response to a pressure change of the system
media.

Pressure Range: 150-4500PSI [10.34-310.26 Bar]

Hysteresis option (HP Series and LP Series only)


Variety of pressure ports and electrical terminations
Pressure switching set point range: Factory set 150 psi to 4500 psi [10.34 bar to 310.26 bar] (High
Pressure) or factory set or field adjustable 3.5 psi to 150 psi [0.24 bar to 10.34 bar] (Low Pressure)
Parameter Value
150 psi to 500 psi
Set point accuracy @ 25C (5 %) 500 psi to 4000 psi (3.5 %)
>4000 psi (2 % [up to 2 %])

Average Deadband n/a

Operating Pressure 5,000 psi max.

Proof Pressure 10,000 psi

Burst Pressure 20,000 psi

5 % to 55 %
Hysteresis
(based on set point range)

10 Hz to 2000 Hz at 15 g
Vibration resistance
20 min/sweep

500 m/sec2, 11 mSEC,


Shock resistance
100 shocks / axis

2. Temperature Sensing Device (LTPCTAA20MBSITX01)

LTPCTAA20MBSITX01 Honeywells Low Temperature Passive Probes,


LTP Series, are a modular range of temperature sensors designed for
potential use in transportation applications. The LTP Series feature a
durable, closed-tip design that maximizes reliability in harsh
applications. The sensors thermistor sensing element effectively
senses liquids and gases because of its enhanced sensitivity, accuracy
and reliability. Easy-to-install threaded mounting provides reliable
operation in harsh environments. Numerous optionsfrom mechanical
and electrical interface simplify installation, allow customers to meet their specific application needs,
and facilitate backwards-compatibility with most existing applications.

Temperature range: -40 C to 150 C [-40 F to 302 F]


Response time [T63.2% of 25 C to 85 C step]: stirred silicon oil <15 s; stirred water <15 s; air flow
10 m/s <20 s
Accuracy: -25 C to 100 C [77 F to 212 F]: 0.8 C
Electrical interface: Deutsch 2-Pin, AMP Minitimer,Bosch Kompakt, Delphi Metri-Pack (AMP Seal
16, and AMP Superseal connector style variants available upon request)
Probe length options: 20 mm to 50 mm
CONTROL DEVICES
(source: Emerson Process Management from http://www2.emersonprocess.com/en-
US/brands/fisher/FieldInstrumentation)

Pneumatic Pressure Controllers

Differential Pressure

Differential pressure controllers use bellows or capsular element to sense two different
pressures. That is then compared to an operator-adjusted set point.

Energy Responsible Controller

Fisher products compare sensed process and send a pneumatic signal to a control element
that maintains the process pressure at or near the set point value.

Gauge Pressure

Gauge pressure controllers measure the difference between the absolute pressure and the
local atmospheric pressure

High-Low Pilot

High-low pressure pilot maintains full output when the process is within the set point
range. If it moves outside of this range, it switches to zero output.

Pneumatic Temperature Controller


Fisher 4196

4196 temperature indicating controllers, used in industries requiring accurate process


monitoring and temperature control, show process temperature and set point on an
easy-to-read process scale.
Liquid Level Controller
1. Pneumatic Liquid Level Controller
Fisher 2500

Fisher 2500 pneumatic level controllers are rugged, dependable, and simply constructed
pneumatic instruments.

Fisher L2 and L2sj

L2 and L2sj rugged liquid level controllers use a displacer sensor to detect liquid level or
the interface of two liquids of different specific gravities.

2. Electric On-Off Liquid Level Controller


Fisher L2e

L2e electric on-off level controller uses a displacer type sensor to detect liquid level or the
interface of two liquids of different specific gravities.

Level Transmitters

Fisher DLC3010 HART Digital Level Controller

DLC3010 digital level controllers are used to measure liquid level, the level of interface
between two liquids, or liquid specific gravity (density).

Fisher DLC3020f Fieldbus Digital Level Controller

The Fieldbus DLC3020f digital level controller is used to measure liquid level or level of
interface between two liquids using displacement sensor technology.

Potrebbero piacerti anche