Sei sulla pagina 1di 27

Refrence Drawaings

1) PC Girder Details :

Stressing Type
Girder ID
Girder Length
Girder Height
Girder Width at Top
Girder with at Bottom
No of Strands/Tendon
No of Strands/Tendon
No of tendons /Girder
Dia of Strand
Jacking force for tendon
Jacking force for tendon
2) Tendon Stressing Sequence :

Stressed Tendon#

Young's Modulus of Elasticity, E


Concrete Strength, fc'

3) Strand Details :

Seven wire strand of grade 270 conforming BS5896 specificatio


theoretical values shall be used

Nominal Diameter,s
Nominal Area, As
Ultimate Tensile Strength "UTS"
Young's Modulus of Elasticity "E"

4) Kangyegangsi Post-Tensioning System Parameters :

Nominal Draw in at Lock off


Anchorage Frictional Losses
Duct Friction Losses
( Co-efficient of Friction)
Wooble Factor, k

Section B : Tendon Angle Calculation & Effective Lengt

Description
L1, Girder Length (m)
L2, Length from girder end to bearing
plate (mm)
* L3, Thickness of Stress Block (mm)
L4, (L2-L3) (mm)
L, Effective Length (L1 - 2xL4) (m)
X=L/2
Y (m)
= 2Y/X

5) Tendon Cross-Sectional Details in PC Girders :

T-Section :

6) Tendon Angle Calculations Detail :


Section C : Tendon Elongation Calculations for PC Gird

Description

Number of Strands/Tendon (No.s)


Jacking Force/Tendon (M.Ton)
Jacking Force/Tendon, Fs (kN)
Jacking Force/Strand (kN)
Co-efficient of Curvature Friction,
Wobble Factor,k (/m)
(rad)
Effective Length, L
Effective Half Length, L/2
.
k.L
. + k.L
e-(. + k.L)
Fs1 = Fs x e-(. + k.L)
e(. + k.L)
e(. + k.L) -1
Favg
(_/)/(. . _ . )
Elongation, L

Notes: Elongation Variation in individual tendon must be within


If the Elongation is beyond
higher force until variation falls within acceptence criteria BUT
BEYOND 80% UTS
Section D : Girder Elastic Shortening, Extension within

1) Input Data :

Desctiption

Girder Length
Effective half length, L/2
Girder X-Sectional Area at Mid
Length, Amid
Jacking Force, Fo
Elastic Modulus of Concrete Ec (For
Concrete Core Strength of 40 Mpa)
Distance from Face of stressing Block
of Wedge gripping system inside the
jack, Lj
Area of Tendon, AT
Modulus Of Elasticity, Es

2) Elastic Shortening in PC Girders :

( )/(

XC = )

3) Extension in Strand within Jack :


XS(= )/( )

4) Pressure Calculations :

Capacity
Jack #
(M.Ton)

KY401 400
KY402 400
Elongation Calculations Date

Project Location

= Both end stressing


= EBT-1-1
= 29.5
= 2
= 1.2
= 0.64
#3 = 12
#1,#2 = 8
= 3
= 15.24
#3 = 2511
#1,#2 = 1674

= #3 fully stressed,#2 50% stressed, #1 fully


= stressed, #2 balance 50% stressed

= 195
= 40

0 conforming BS5896 specifications having following


d

= 15.24
= 150
= 209.25
= 195

ng System Parameters :

= 6
= 2 to 4
=
0.2
=
= 0.0017
Flexible metal sheathing
gle Calculation & Effective Length Details :

Tendon#1 Tendon#2 Tendon#3


29.5 29.5 29.5

0 0 0

55 55 60
55 55 60
29.39 29.39 29.38
14.695 14.695 14.69
0.3373 0.3373 0.9673
0.045900 0.045900 0.131688
* Specification from manufacturer
ails in PC Girders :

= 2Y/X
ngation Calculations for PC Girders :

T-Girder 29.5 m
Kangyegangsi Parameters Remarks
Tendon# 1 Tendon# 2 Tendon# 3
8 8 12
170.6422018349 170.6422018 255.963303
1674 1674 2511
209.25 209.25 209.25
0.2 0.2 0.2
0.0017 0.0017 0.0017
0.045899966 0.045899966 0.13168822
29.39 29.39 29.38
14.695 14.695 14.69
0.00918 0.00918 0.02634
0.02498 0.02498 0.02497
0.03416 0.03416 0.05131
0.96642 0.96642 0.94998
1617.78 1617.78 2385.41
1.03475 1.03475 1.05265
0.03475 0.03475 0.05265
1645.89 1645.89 2448.20
. _ . )
103 103 102

n individual tendon must be within 2%


If the Elongation is beyond -2% then stress the tendon to a
ls within acceptence criteria BUT NEVER STRESS A TENDON
tic Shortening, Extension within Jack and Pressure Calculation :

T-Girder (29.5 m)
Unit
Tendon#1 Tendon#2 Tendon#3
m 29.5 29.5 29.5
m 14.695 14.695 14.69

mm2 804400 804400 804400

KN 1674 1674 2511

Gpa 29.73 29.73 29.73

mm 577 577 577

mm2 1200 1200 1800


KN/mm2 195 195 195

rders :

mm 2.07 2.07 3.10

0.9563958178 0.9563958178 1.434105604

Jack :
mm 4.13 4.13 4.13

Piston Area P=Fo/Ap (Bars)


(cm2)

791.68 211 211 317


791.68 211 211 317
m
m
m
m
No.'s
No.'s
No.'s
mm
KN
KN

tressed, #1 fully
0% stressed

Gpa
MPa

mm
mm2
KN
KN/mm2

mm
%
manufacturer
31975.35
31975.3505062885
Both End Stressing

Single End Stressing

#1,#2 8 1674
#1,#2 10 2092.5

#3 12 2511

Duct diameter, mm 85.5

A B
X mm 0 300 2000 2250 4750 7250 9750
Ymm

Tendon-3 1400 1321 1113 1085 835 640 501

Tendon1&2 450 393 314 304 220 154 107


C D
12250 14750 17250 19750 22250 24750 27250 27500 29200

418 390 418 501 640 835 1085 1113 1321

79 70 79 107 154 220 304 314 393


Grider ID No Girder Length H Top W Bottom W

EBT-1-1 29.5 2 1.2 0.64

EBT-1-2 29.5 2 1.2 0.64

EBT-2-1 29.71 2 1.2 0.64

EBT-2-2 29.71 2 1.2 0.64

EBT-2-3 29.71 2 1.2 0.64

EBT-2-4 29.71 2 1.2 0.64

MBT-1-1 29.5 2 1.2 0.64

MBT-2-2 29.71 2 1.2 0.64


D
Jacking Force
KN
Jacking Force
29500 KN

1400 2511

450 1674
Elastic Shortening

Input Parameters

Ac mm2 804400
Ix mm4 6.39E+10 Iy 4.00E+10
rx 2
mm 2
7.94E+04 ry 2
4.97E+04
Aps mm 2
4200
fc' Mpa 40
fpu Mpa 1860
fci' Mpa 40
Eps Gpa 195
Ec Gpa 29.73
n 6.56

N.A distance mm 1107


eccentricity, ec
Stressing Sequence
Tendon 3 mm 674.25
Tendon 1,2 mm 994.25

Elastic shortening of T-3 Elastic shortening of


due to T-1 and T-2 T-2 due to T-1
(100%)

fcs Mpa 39.31 27.18


fpES Mpa 257.90 178.2879283682
Loss 464.22 213.9455140418
( )/
Elongation 0.29 0.13
( )
#3 fully stressed,#2 50% stressed, #1
fully stressed, #2 balance 50%
stressed

Elastic shortening of
T-1 due to T-2 (rem.
50%)

13.59 fcs = / (1 +
89.1439641841 ^2/^2 )
106.9727570209

Potrebbero piacerti anche