Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
You must attribute the work in the manner specified by the author or licensor
RESUMO
O objetivo deste estudo foi dimensionar e analisar o desempenho de um leito cultivado (wetland) no tratamento
do esgoto sanitrio in natura. O prottipo foi instalado no laboratrio de Resduos Slidos da Universidade
Federal do Tocantins em outubro e novembro de 2010. As macrfitas do gnero Eichhornia, foram coletas as
margens do logo da UHE Luiz Eduardo Magalhes no dia 10 de outubro de 2010. O afluente foi coletado na
Estao de Tratamento de Esgoto da Universidade Federal, no dia 25 de outubro de 2010. A degradao das
substncias se processou segundo uma reao de primeira ordem. A temperatura mdia oscilou entre 24.9 C e
29.3 C. O wetland apresentou remoo de 60.85% para a DBO, de 99.83% para a NH 3 de 97.46% para o NO2-,
de 0.80% para o NO3-, de 95.96% para fosfato, de 35.81% para coliformes totais e de 78.62% para coliformes
fecais. As variveis trmicas e ambientais determinaram a fitodegradao, a biodegradao dos poluentes e a
rea superficial requerida. O modelo matemtico desenvolvido eficiente para dimensionar wetlands a partir do
coeficiente de decaimento dos poluentes e da concentrao requerida.
Palavras-chave: avaliao; modelagem; poluentes; saneamento ambiental
ABSTRACT
The objective of this study was to analyze the performance of a wetland for the proposition sizing. The prototype
was installed in the laboratory of Solid Waste, Federal University of Tocantins, in October and November 2010.
This plant of the genus Eichhornia, were collected on the banks of the UHE Luiz Eduardo Magalhes on
October 10, 2010. The influent was collected at Station Sewage Treatment, Federal University, on October 25,
2010. The degradation of the substances if processed according to a first order reaction. The average temperature
ranged between 24.9 C and 29.3 C. The wetland showed removal of 60.85% for DBO, of 99.83% for NH 3, of
97.46% for NO2-, of 0.80% for NO3-, of 95.96% for phosphate, of 35.81% coliforms and 78.62% for fecal
coliforms. The thermal and environmental variables determined the phytodegradation, the biodegradation of
pollutants and the surface area required. The mathematical model is efficient for sizing wetlands from the decay
coefficient of the pollutants and concentration required.
Keywords: assessment; modeling; pollution; environmental sanitation
1
Engenheiro ambiental formado pelo Universidade Federal do Tocantins e pesquisador do Laboratrio de Resduos Slidos
da Universidade Federal do Tocantins.
2
Professor, Doutor. Orientador. Universidade Federal de Tocantis. e-mail: rmontanhini@mail.uft.edu.br
onde: onde:
x x
n
n - nmero de dados da amostra. 2
i
Podemos ainda utilizar a notao de 2 i 1
(20)
n 1
somatrio, conforme Equao (18).
onde: