1. Ensure that the case has an assay attached to the flowsheets fluid package. Add a
Petroleum Shift Reactor unitop on the flowsheet.
2. Open the Design>Connections page and add desired feed, product, energy, calculated
feed (if any) streams.
7. On the Product Specs>Product Cuts page specify the Temperature, IBP and FBP of
the products and calculated feeds. Note that calculated feeds are treated almost as
products in model calculations except that (1) the flow is treated negative for material
balance purpose, and (2) properties cannot be shifted.
8. On Product Specs>Assay Properties page select properties you want to shift. For the
Hydrotr. Diesel stream select Sulfur Content and Liquid Density as the properties to
be shifted.
9. On the Product Specs>Property Shift page specify the base and shift values for the
properties.
10. Now specify the flowrate, temperature, pressure and composition for the DS1 feed
stream. Since some of the feed properties are model independent variables, ensure
that the feed has all the specified properties. If a property is missing you can see a
trace warning message.