Sei sulla pagina 1di 6

InteliNanoNT

GEN-SET CONTROLLER

Description
InteliNanoNT is a cost effective diesel
and gasoline generator set controller
which offers outstanding protection,
monitoring and control for small
and middle size generator sets.

There are tree different types available:

 MRS
 AMF
 PLUS

The InteliNanoNT MRS, AMF


andPLUS boast large andpowerful
graphical displays.

All InteliNanoNT controllers communicate


with license-free PC software via the
integrated USB port for your convenience.

This software allows users to


configure all the inputs, outputs and
important parameters freely, as well
as update the controllers firmware
to suit individual requirements.

All InteliNanoNT controllers can


communicate via standard and proprietary
CAN J1939 communication protocols to
awide range of EFI engines, which include
Caterpillar, Cummins, Detroit Diesel,
Deutz, GM, Isuzu, Iveco, John Deere,
Kubota, MAN, MTU, Perkins, Scania,
Benefits Sisu, Volvo Penta, Yanmar and others.

 Supercompact and attractive design  Zero power consumption  ComAps uncompromised


 Integrated solution less wiring mode, i.e. extended battery life quality and performance
and external components  Weak battery genset starting  MRS and AMF in one model,
 Standard industrial cutout dimensions  Event Log (10 events) i.e. one stock only
 The biggest graphical display  Easy and user-friendly  High speed engine support
in its class installation / operation  Dedicated for diesel and gasoline engines
 Language free, on display only symbols  Perfect price / performance ratio  Shorter commisioning time USB
and numbers, no translation needed  USB one cord programming one-cordpowersupplyandprogramming
 USB communication interface and CAN  All setpoints and I/Os
for outstanding support of EFI engines configurable via front panel

ComAp is a member of ComAp products meet the highest


AMPS (The Association of standards, with every stage of production
Manufacturers of Power undertaken in accordance with the ISO
MEMBER generating Systems). certification obtained in 1998.
Features

 3 phase mains measurement  History  Mechanical and operation


Over/Under frequency Running hours parameters
Over/Under voltage 10 events, warnings or shutdown Unit dimension 118 108 mm
Phase rotation alarms with running hours stamp Cutout dimension 96 96 mm
Yellow and red alarms from ECU Sealed front face rated for
 3 phase generator protection 7)
IP65 for GASKET 4x405 4)
Over/Under frequency  Inputs and outputs Operation temperature
Over/Under voltage 3 configurable analog inputs with -20 C to +70 C
Phase rotation wide list of predefined senders2) Power supply voltage 536 V
Overcurrent/Overload 6) COM terminal for analog inputs Voltage drops shorter than
6 binary inputs3) 50ms do not affect operation
 True RMS voltage measurement 1 binary input is dedicated for
3 phase mains voltage1) controller remote wake up
3 phase generator voltage7) All outputs have positive
Voltage range 277 V p-n, logic (high side) InteliNanoNT controllers support
480 V p-p All outputs are overcurrent protected J1939 for all major brands:
Maximal measured 2 high current 6 A long 10 A short Caterpillar MAN
voltage 300 V p-n 4 low current 0,5 A Cummins MTU
D+ pre-excitation terminal Detroit Diesel Perkins
Deutz Scania
 True RMS current measurement 6)
GM Sisu
1 generator phase current  EFI engine support Isuzu Volvo Penta
Current range 5 A Engine specific J1939 for all major Iveco Yanmar
Maximal measured current 10 A manufacturers (see table right) John Deere and others
CT ratio range 1 5000 Diagnostic messages Kubota
(SPN, FMI number)
 Engine protection
Over/Under speed  Miscellaneous features
High temperature Zero power consumptionmode
Oil pressure Maintenance warning
Low fuel warning Customer logo screen
Battery flat detection Weak battery genset starting
USB one-cord power supply KEY
 Shutdown warning and programming MRS manual and remote start controller
All setpoints and I/Os AMF automatic mains failure start controller
 User interface configurable via front panel 1)
Only for AMF model
Graphic 128 64 pixel display AMF and MRS in one model1) 2)
Analog inputs are shared with binary inputs
Icon menu, no text Voltage autodetect5) 3)
1 binary input is shared with binary output
Setpoints adjustable via Gasoline engine support-choke output 4)
Optional GASKET has to be ordered separately
controller buttons or PC 5)
Only when AMF mode is disabled
Buttons with mechanical feedback  Communication interface 6)
Only for InteliNano Plus model
Special LCD screen / USB on board InteliNano Plus 3 phases
7)

Light tower support CAN interface (J1939 only) in MRSmode / 1 or 2 phases in AMF mode

Order codes ANSI CODES

Product Order code ANSI code Protection

InteliNanoNT MRS IN-NT MRS 59 Overvoltage

InteliNanoNT AMF IN-NT AMF 27 Undervoltage

InteliNanoNT
PLUS IN-NT PLUS 81H Overfrequency

IP65 Gasket GASKET 4x405 81L Underfrequency

47 Phase rotation*

71 Gas level

* Fixed setting

InteliNano NT
Typical aplications

PRIME POWER SYSTEM


 Manual and remote start
of gen-sets with electronic
engines. InteliNanoNT MRS
S
MR
starts, controls and monitors the liNa
no
T
N

Inte
gen-set and controls the circuit
breaker to supply the load.
 Generator is protected by built
in over/under voltage and
frequency protection systems.
 Controller communicates with
engine management unit via
CAN J1939 bus and shows no
NT Plu
s
liNa
Inte
engine values and alarms
on graphical LCD screen.
 Prolonged battery lifetime
controller enters to sleep
mode when generator
is not used long time.
 Special LCD screen for
Light tower support

STANDBY SYSTEM
 Stand-by gen-set with electronic
engine. InteliNanoNT AMF
continuously monitors a mains
supply and automatically MAIN
S

starts an engine and switches


load to a standby generator
set in case of failure.
 Generator is protected by built
in over/under voltage and
frequency protection systems.
R
ITTE
 Controller communicates with RA NSM
TV T MF
oN A
T

engine management unit by Nan


Inteli
9
CAN J1939 bus and shows J193

engine values and alarms


on graphical LCD screen.
INE
ENG M
ROO

-SET
GEN

InteliNano NT
GND

Schematic diagrams PC

SUPPLY

ALA
POWER VDC
5 to 36 -

RM
+ USB

STO
PUTS
RY OUT
4 BINA

P
BE
UP TO DE) 2 CAN UIT
SI
(HIGH TED FOR CIRC
L
6 DEDICA RS CONTRO
UP TO INPUTS BREAKE
BINARY

F
an oNT AM
InteliN MAINS

MEA
ATOR CAN -
J1939
GENER

VOL

SUR
InteliNano NT
MRS

MEA

TAG

EME
VOL

SUR
3
UP TO

E
E
ENGIN

NT
G

TAG
ANALO

EME
RY
2 BINA
OUTPU
TS INPUTS

NT
GND (HIGH T
CURREN DE)

GEN

MAIN
D+ HI G H SI

E
RAT

SC
Coo
PC

Fue

OR

.B. C
Oil P

3ph
Start

lant
Fue

l Le

C
SUPPLY

ONT
.B. C
ress
Aux xcitatio
ALA

Pre

er
POWER VDC

l So

3ph
Tem
MAINS

vel
5 to 36

R
ure
e
-

Alte

ONT
RM

leno

OL
+

pera
USB
STO

PUTS

rnato
RY OUT

R
id

ture
2 BINA

OL
P

BE
UP TO DE) 1 CAN UIT

n
r
IG H SI R CI RC
(H TED FO L
6 DEDICA RS CONTRO
UP TO INPUTS BREA KE
BINARY

ano
NT MRS LOAD

InteliN GENER
ATOR CAN -
J1939
11

Values
+ Fault
Codes
MEA

ATO R
GENER quest
VOL

SUR

3 eed Re J1939
E UP TO top - Sp
ENGIN G LINE Start/S
/ GASO
TAG

ANALO
EME

RY
2 BINA DIESEL
OUTPU
TS INPUTS
E

(HIGH
T

T 1 ECU
CURREN DE)
GEN

SI
D+ HIGH
E

InteliNanoNT AMF
RAT
Coo
Oil P

OR
Start

lant
Fue

C
re
Aux xcitatio

.B. C
Pre

er

ssu
l So

3ph
Tem
e

re
Alte

leno

ONT
pera
rnato

id

ROL
ture
n
r

LOAD

1
Codes
+ Fault
Values
OR GND
GENERAT quest
eed Re J1939
LINE top - Sp
ASO Start/S
DIE SEL / G

PC
1 ECU
SUPPLY
ALA

POWER VDC
5 to 36 -
RM

+ USB
STO

PUTS
RY OUT
P

2 BINA DE)
SI
(HIGH
6
UP TO INPUTS

s
oNT Plu
BINARY

an
InteliN plicatio
n MAINS
MEA

AMF ap ATOR CAN -


J1939
GENER
VOL

SUR
MEA

InteliNanoNT PLUS
TAG

EME
VOL
CUR

SUR

3
UP TO
E

E
TAG

ENGIN
NT

G
ANALO
REN

EME

RY
2 BINA
INPUTS
E

TS
OUTPU
T

NT

(HIGH T
CURREN DE)
GEN

MAIN

SI
GND D+ HIGH
ERA

SC
TOR
Coo
Fue

.B. C
Oil P

3ph
Start

lant
Fue

l Le

C.B

PC
O
ress
Aux xcitatio
Pre

er

NTR
l So

1ph
Tem

MAINS
vel

. CO
1ph
ure
e
Alte

SUPPLY
leno

O
pera
ALA

POWER VDC
NTR

L
rnato

5 to 36
id

-
RM

ture

OL

+ USB
n
STO

PUTS
RY OUT
P

3 BINA DE)
SI
(HIGH
6
UP TO INPUTS

Plus
BINARY LOAD
NT
no
nteliNa
11

IMRS ap
plicatio
n
ATOR CAN -
J1939
Values
+ Fault Code
s

GENER GENER
ATOR
d Requ
est
MEA

ee J1939
top - Sp
LINE Start/S
/ GASO
VOL
CUR

DIESEL
SUR

3
E UP TO
TAG

ENGIN G
REN

ANALO
EME

RY
2 BINA ECU
INPUTS
E

TS 1
OUTPU
T

NT

(HIGH T
CU EN DE)
RR
GEN

SI
D+ HIGH
ERA
Coo

TOR
Oil P
Start

lant
Fue

C.B
ress
Aux xcitatio
Pre

er
l So

3ph
Tem

1ph

. CO
ure
e
Alte

leno

pera

NTR
rnato

id

ture

OL
n
r

LOAD

1
Codes
+ Fault
Values
OR
G ENERAT quest
eed Re J1939
top - Sp
OLINE Start/S
L / GAS
DIESE

1 ECU

InteliNano NT
Available models

InteliNanoNT MRS InteliNanoNT AMF InteliNanoNT PLUS


MANUAL AND REMOTE AUTOMATIC MAINS FAILURE AMF AND MRS CONTROLLER
START CONTROLLER WITH START CONTROLLER WITH WITH CURRENT MEASUREMENT
SUPPORT FOR EFI ENGINE SUPPORT FOR EFI ENGINE AND SUPPORT FOR EFI ENGINE

 3 phase generator voltage  3 phase mains voltage  3 phase mains voltage measurement
measurement measurement  1/3 1) phase generator
 Up to 3 analog inputs  3 phase generator voltage voltage measurement
(shared with binary inputs) measurement  1 phase generator current
 COM terminal for analog  Up to 3 analog inputs measurement
measurement (shared with binary inputs)  Up to 3 analog inputs
 Up to 6 binary inputs (1 binary  COM terminal for analog (shared with binary inputs)
input is shared with binary output) measurement  COM terminal for analog
 2 high side high current outputs  Up to 6 binary inputs (1 binary measurement
 2 high side binary outputs input is shared with binary output)  up to 6 binary inputs (1 binary input
 Automatic or manual GCB control  2 high side high current outputs is shared with binary output)
 CAN J1939  4 high side binary outputs  2 high side high current outputs
 USB  Automatic or manual MCB and  4 high side binary outputs
 Big graphical LCD GCB control  Automatic or manual MCB
 D+ pre-excitation terminal  CAN J1939 and GCB control
 Zero power consumption  USB  CAN J1939
 Big graphical LCD  USB
 D+ pre-excitation terminal  Big graphical LCD
 Zero power consumption mode  D+ pre-excitation terminal
 AMF and MRS in one model  Zero power consumption mode
 AMF and MRS in one model

KEY
3/3 phase when used as MRS controller
1)

References

Slovenia
STUBELJ

Stubelj is a Slovenian company with 25 years experience of producing


and selling 2.0 2000 kVA generating sets, and providing
all services connected with this business.

Our company has been using ComAp controllers for many years.
We have had a good long-term experience with InteliLiteNT and InteliGenNT
controllers. We are now using the new InteliNanoNT controllers
on our smaller generating sets, which we are very happy with.
The InteliNanoNT gen-set controllers provide protection, monitoring
and control to small-to-medium sized generator sets and pack
plenty of power into a small unit at a very good price.

Marko Stubelj
Purchasing Manager
www.stubelj.si

InteliNano NT
Functions chart for InteliNanoNT models
InteliNanoNT MRS InteliNanoNT AMF InteliNanoNT PLUS

Model MRS AMF PLUS

Order code IN-NT MRS IN-NT AMF IN-NT PLUS

Binary inputs/outputs 6/4 1) 6/6 1) 6/6 1)

Analog inputs 3 2) 3 2) 3 2)

AMF function l l

MRS function l l l

Input configuration l l l

Output configuration l l l

Voltage measurement Gen. / Mains 3 ph / 3 ph / 3 ph 1 ph 4)


/ 3 ph

Current Measurement 1 ph

Voltage autodetect l l 3) l 3)

Generator protections l l l

Event log / Running hours history l l l

GCB/MCB control with feedback l/ l/l l/l

D+ battery charging alternator circuit l l l

Engine hours l l l

CAN-J1939 interface l l l

USB communication port l l l

LCD screen l l l

Alarm LED l l l

Weak battery genset starting l l l

Maintenance warning l l l

Zero power consumption l l l

Light tower support l l 3)


l 3)

IP65

KEY 1)
1 binary input is shared with binary output 2)
Analog inputs are shared with binary inputs
3)
Only when AMF function is disabled 4)
3 ph when used as MRS controller l included excluded optional

For more information about our products and applications visit

www.comap.cz
MANUFACTURER: LOCAL DISTRIBUTOR / PARTNER:

ComAp a.s.

Czech Republic
Phone: + 420246012111
Fax: + 420266316647
E-mail: info@comap.cz
Internet: www.comap.cz

Customer satisfaction is our mission. We continuously develop our people to be the best to succeed in our mission.

ComAp. Features and specification are subject to change without prior notice. 2014-01/CPLENANO

Potrebbero piacerti anche