Allowable Intake Restriction (Maximum)(Multiple Turbocharger Engines only):
With Clean Filter Element 127 mm H2O [5 in H20]
With Dirty Filter Element 381 mm H2O [15 in H20]
https://qsol.cummins.com/qs3/pubsys2/xml/en/procedures/84/84-018-019.html 30/09/2015
Air Intake System Pgina 2 de 3
Turbocharger Compressor Bypass Valve - Commanded Position Percent Duty Cycle and 0-5-VDC Position
Feedback Signal Specifications
Value Commanded Position Commanded Percent Duty Cycle 0-5-VDC Position Feedback
0 10 - 14 0.4 - 0.7
10 17 - 21 0.9 - 1.1
20 25 - 28 1.3 - 1.5
30 33 - 37 1.7 - 1.9
40 41 - 44 2.1 - 2.3
50 49 - 54 2.5 - 2.7
60 55 - 60 2.9 - 3.0
70 65 - 70 3.3 - 3.5
80 73 - 78 3.7 - 3.9
90 81 - 86 4.1 - 4.3