API 610, Table 5 gives the allowable forces and moments on the Pump Nozzles (Suction
Piping Layout Drawings Abbreviations and
and Discharge). However, if the loads acting on the Pump nozzles exceed these values, Legends
the allowable loads can be increased to 2 times, provided the criteria speci ed in Annex July 12, 2017
F are satis ed. This shall be approved and con rmed by the Pump Vendor. As a general
Nozzle Orientation Drawing
practice, approval shall be taken from the vendor for 2 times API 610 at the initial stage
July 12, 2017
of the project.
Centrifugal Pump Piping Design Layout
July 12, 2017
The minimum allowable nozzle loads shall be as provided by the Pump Supplier.
The minimum allowable nozzle loads shall be as per API676, Table 2. However, if one or
more components of the forces and moments are still exceeding, same shall be
approved & agreed with the Pump Vendor.
The allowable forces and moments acting on the nozzles of centrifugal compressors
shall be designed in accordance with API 617, the forces and moments shall be 1.85
times the values based on the load criteria of NEMA SM23. However, if one or more
http://www.piping-engineering.com/nozzle-loads-part-2.html# 1/3
10/18/2017 Nozzle loads - Part 2 - | Piping-engineering
components of the forces and moments are still exceeding, same shall be approved &
Piping-engineering
agreed with the Vendor. 11,987 likes
Reciprocating Compressors
Google+
The minimum allowable nozzle loads for Rotary Positive Displacement Compressors is
generally taken as 1.85 times NEMA SM23 Values. However, if one or more components
of the forces and moments are still exceeding, same shall be approved & agreed with
the Vendor.
The allowable nozzle loads for Brazed Aluminium Plate-Fin HeatExchanger shall be 3
times the value in ALPEMA (Standards of theBrazed Aluminium Plate-Fin Heat
Exchanger Manufacturers Association) Table 5-1. However, it shall be approved and
agreed by the Vendor.
The minimum allowable nozzle loads on Air-Cooled Heat Exchangers due topiping
reactions shall be as listed below.
Gas Turbines
The minimum allowable nozzle loads for Gas Turbines shall be as provided by Supplier.
Fired Heaters
The minimum allowable nozzle loads for Fired Heaters shall be THREE times as
speci ed in API-560. In case the same is procured as a package item, Nozzle loads shall
be as per Cl. 5.2.14 below.
Steam Turbines-NEMA SM 23
The minimum allowable nozzle loads for Steam Turbine is generally taken as 1.85 times
NEMA SM23 Values. However, if one or more components of the forces and moments
are still exceeding, same shall be approved & agreed with the Vendor.
http://www.piping-engineering.com/nozzle-loads-part-2.html# 2/3
10/18/2017 Nozzle loads - Part 2 - | Piping-engineering
The minimum allowable nozzle loads for any other proprietary equipment shall be as
provided by Supplier.