INSTRUCTION MANUAL
NEC Corporation
TOKYO, JAPAN
ROI-S03895-05EE CONTENTS
030610
PASOLINK +
(STM-1/1+1 SYSTEM)
DESCRIPTION
CONTENTS
TITLE PAGE
1. GENERAL 1-1
CL-1
CONTENTS ROI-S03895
TITLE PAGE
CL-2
2 pages
ROI-S03895 GENERAL
1. GENERAL
This section provides descriptive information on the 6/7/8/11/13/15/18/23/
26/38 GHz 150 MB digital microwave radio system for the synchronous
digital hierarchy (SDH).
1-1
ROI-S03895 SYSTEM DESCRIPTION
2. SYSTEM DESCRIPTION
The system description outlines the system configuration, system
performance, RF channel plan, alarm and control, protection switching,
and power supply.
As illustrated in Fig. 2-2 and Fig. 2-3, the ( ) GHz 150 MB SDH
microwave radio system is a 1-hop (point-to-point) system between two
terminal stations, and is configured in the 1 + 1 Twin-path system/hot-
standby (HS) system and HS/Space diversity (SD) system.
G7894 MD UNIT
PWR
IF
IN/OUT
+
PWR
! WARNING
-43V OUTPUT
TURN OFF POWER
BEFORE DISCONNECTING
IF CABLE FUSE (7.5A) SEL V
IDU
2-1
SYSTEM DESCRIPTION ROI-S03895
IFL FG RX LEV
MON
2-2
ROI-S03895 SYSTEM DESCRIPTION
PNMS/PNMT PNMS/PNMT
LCT SYNTH SYNTH LCT
CTRL CONT CONT (LO) CTRL
OW (LO) OW
ANT ANT
ODU ODU
MODEM INTFC MODEM
RF RF INTFC
CKT CKT
SYNTH SYNTH
(LO) CONT CONT (LO)
OW OW
IN/OUT IN/OUT
10/100BASE-T : 10/100BASE-T Interface LCT : Local Craft Terminal PNMS : Pasolink Network Management System
INTFC LO : Local Oscillator PNMT : Pasolink Network Management Terminal
150M INTFC : Electrical STM-1 Interface MODEM : Modulator Demodulator RF CKT : Radio Frequency Circuit
ANT : Antenna ODU : Outdoor Unit (Transmitter-Receiver) STM-1 : Synchronous Transport Module-1
CONT : Control OPT INTFC : Optical STM-1 Interface SYNTH : Synthesizer
CTRL : Control OW : Orderwire WS : Wayside
DC-DC CONV : DC-DC Converter
IDU : Indoor Unit (Modulator-Demodulator)
Notes: 1. * Optional.
LAN : Local Area Network 2. ** Applies to the 32 QAM system
only.
Fig. 2-2 SDH Digital Microwave Radio System 1+1 Twin-path/Hot-standby System Block Diagram
2-3/4
ROI-S03895 SYSTEM DESCRIPTION
ANT ANT
10 BASE-T LAN CARD* LAN CARD* 10 BASE-T
OW OW
IN/OUT IN/OUT
ODU ODU
MODEM INTFC MODEM
RF RF INTFC
CKT CKT
SYNTH SYNTH
(LO) CONT CONT (LO)
OW OW
IN/OUT IN/OUT
10/100BASE-T : 10/100BASE-T Interface LCT : Local Craft Terminal PNMS : Pasolink Network Management System
INTFC LO : Local Oscillator PNMT : Pasolink Network Management Terminal
150M INTFC : Electrical STM-1 Interface MODEM : Modulator Demodulator RF CKT : Radio Frequency Circuit
ANT : Antenna ODU : Outdoor Unit (Transmitter-Receiver) STM-1 : Synchronous Transport Module-1
CONT : Control OPT INTFC : Optical STM-1 Interface SYNTH : Synthesizer
CTRL : Control OW : Orderwire WS : Wayside
DC-DC CONV : DC-DC Converter
IDU : Indoor Unit (Modulator-Demodulator) Notes: 1. * Optional.
LAN : Local Area Network 2. ** Applies to the 32 QAM system only.
: When the No.1 channel TX side is working.
: When the No.2 channel TX side is working.
Fig. 2-3 SDH Digital Microwave Radio System Hot-standby/Space Diversity System Block Diagram
2-5/6
ROI-S03895 SYSTEM DESCRIPTION
Quantity
18 23 26 38 13 15 18 23 26 38 18 23 26 38 13 15 18 23 26 38
6 GHz 7 GHz 8 GHz 11 GHz 6 GHz 7 GHz 8 GHz 11 GHz
GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz
MDP-150MB5T-3
1 1 1 1 1 1 1 1
(G7891[ ])
MDP-150MB7T-1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
(G7892[ ])
TRP-6G-1AA (SHG)
2 2
(G8222[ ])
TRP-7G-1AA (SHG)
2 2
(G8223[ ])
TRP-8G-1AA (SHG)
2 2
(G8224[ ])
TRP-11G-1AA (SHG)
2 2
(G8737[ ])
TRP-13G-1AA (SHG)
2 2
(G7965[ ])
TRP-15G-1AA (SHG)
2 2
(G8550[ ])
TRP-18G-1AA (HG/SHG)
2 2
(G8381[ ])
TRP-18G-1AA (SHG)
2 2
(G8381[ ])
TRP-23G-1AA (HG/SHG)
2 2
(G7960[ ])
TRP-23G-1AA (SHG)
2 2
(G7960[ ])
TRP-26G-1AA (HG/SHG)
2 2
(G8516[ ])
TRP-26G-1AA (SHG)
2 2
(G8516[ ])
TRP-38G-1AA (HG/SHG)
2 2
(G8512[ ])
2-7/8
ROI-S03895 SYSTEM DESCRIPTION
Quantity
18 23 26 38 13 15 18 23 26 38 18 23 26 38 13 15 18 23 26 38
6 GHz 7 GHz 8 GHz 11 GHz 6 GHz 7 GHz 8 GHz 11 GHz
GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz GHz
TRP-38G-1AA (SHG)
2 2
(G8512[ ])
HYBRID 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
ANTENNA 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2
2-9/10
ROI-S03895 SYSTEM DESCRIPTION
A. IDU
Transmission Signal STM-1
Transmission Capacity 155.52 Mbps
Symbol Frequency
32 QAM: 41.51808 MHz
128 QAM: 24.236883 MHz
Modulation 32/128 QAM
Demodulation Coherent detection
Forward Error Correction (FEC) Reed Solomon (RS)
Data Interface Electrical/Optical
SOH Termination RST mode
BB Loopback Near-end/Far-end
IF Loopback Local only
INTERFACE
Either of electrical or optical interface
can be selected by selecting the 150M
INTFC or OPT INTFC module.
(1) STM-1 (Electrical)
Type ITU-T G.703
Bit Rate 155.520 Mbit/s
Level 1 Vp-p (nominal)
Code Format Coded mark inversion (CMI)
Impedance 75 ohms, unbalanced
(2) STM-1 (Optical)
Type ITU-T G.957: S-1.1
Bit Rate 155.520 Mbit/s
Level Intra-office
2-11
SYSTEM DESCRIPTION ROI-S03895
2-12
ROI-S03895 SYSTEM DESCRIPTION
2-13
ROI-S03895 SYSTEM DESCRIPTION
B. ODU
Frequency Band 6 GHz 7 GHz 8 GHz 11 GHz 13 GHz 15 GHz 18 GHz 23 GHz 26 GHz 38 GHz
Frequency Range 5.9 to 8.5 GHz 10.7 to 11.7 GHz 12.75 to 13.25 GHz 14.2 to 15.35 GHz 17.7 to 19.7 GHz 21.2 to 23.6 GHz 24.25 to 27.0 GHz 37.0 to 40.0 GHz
TX Output Power
32 QAM : +18 dBm +18 dBm +17 dBm +13.5 dBm
128 QAM : +25 dBm +25 dBm +25 dBm +16.5 dBm +16.5 dBm +16.5 dBm +15 dBm +15 dBm +14 dBm +10.5 dBm
Frequency Stability 6 ppm 6 ppm 6 ppm 6 ppm 6 ppm 6 ppm 6 ppm 6 ppm 6 ppm 6 ppm
Receiver Threshold
BER 10-6
32 QAM : 76 dBm 76 dBm 75.5 dBm 74.0 dBm
128 QAM : 68.0 dBm 68.0 dBm 68.0 dBm 66.0 dBm 66.0 dBm 66.0 dBm 67.5 dBm 67.5 dBm 67.0 dBm 65.5 dBm
BER 10-3
32 QAM : 77 dBm 77 dBm 76.5 dBm 75.0 dBm
128 QAM : 69.0 dBm 69.0 dBm 69.0 dBm 67.0 dBm 67.0 dBm 67.0 dBm 68.5 dBm 68.5 dBm 68.0 dBm 64.5 dBm
System Gain
BER 10-6
32 QAM : 94.0 dB 94.0 dB 92.5 dB 87.5 dB
128 QAM : 93.0 dB 93.0 dB 93.0 dB 82.5 dB 82.5 dB 82.5 dB 82.5 dB 82.5 dB 81.0 dB 76.0 dB
BER 10-3
32 QAM : 95.0 dB 95.0 dB 93.5 dB 88.5 dB
128 QAM : 94.0 dB 94.0 dB 94.0 dB 83.5 dB 83.5 dB 83.5 dB 83.5 dB 83.5 dB 82.0 dB 75.0 dB
ATPC/MTPC Range
32 QAM : 23 to 0 dB
128 QAM : 20 to 0 dB
Additional Attenuation for
5 dB
Span Equalization
2-15/16
ROI-S03895 SYSTEM DESCRIPTION
C. OVERALL
IDU-ODU Interconnection Single coaxial cable, 50 ohms (impedance)
Cable
Interconnection Cable 150 m (5D-FB coaxial cable or equivalent)
(Type and Maximum Cable Length) 300 m (8D-FB coaxial cable or equivalent)
350 m (10D-FB coaxial cable or equivalent)
450 m (12D-FB coaxial cable or equivalent)
Primary Voltage (Safety 48 V DC (36 to 60 V) or +48 V DC (+36 to +60
Extra-Low Voltage (SEL V)) V)/24 V DC (20 to 60 V) or +24 V DC (+20 to
+60 V), optional
Power Consumption (IDU+ODU) 130 W or less
Dimension
IDU 482 mm (W) 132 mm (H) 300 mm (D)
ODU
6/7/8 GHz 260 mm (W) 410 mm (H) 190 mm (D)
11-38 GHz 240 mm (W) 243 mm (H) 124 mm (D)
Weight
IDU Approx. 13 kg (Including optional module)
ODU
6/7/8 GHz Approx. 10 kg
11-38 GHz Approx. 5 kg
Temperature Range
Guaranteed Operation
IDU 5C to +50C
ODU 33C to +50C
Workable Operation
IDU 10C to +55C
ODU 40C to +55C
Transport and Storage
IDU 40C to +70C
ODU 40C to +70C
Relative Humidity Less than 90% at 50C (Non-condensing)
2-17
SYSTEM DESCRIPTION ROI-S03895
Altitude Up to 4,000 m
2-18
ROI-S03895 SYSTEM DESCRIPTION
The alarm and control system is shown in Fig. 2-4. The functions of the
alarm and control circuit are as follows:
Loopback control
MS-AIS generation
Alarm indication and reporting functions are provided with the IDU.
Summary alarm indicators using LEDs are provided for the ODU and
IDU, separately. ODU alarms detected by the alarm detection circuit in
the ODU are sent to the CTRL module in the IDU. This causes the ODU
alarm indicator on the IDU front panel to turn on. Similarly, any IDU
related alarms that are detected will cause the IDU alarm indicator on the
IDU front panel to turn on. External reporting of alarms is also provided
through closed relay contacts accessible via the front panel interface (see
Table 2-3).
2-19
SYSTEM DESCRIPTION ROI-S03895
TX POWER
RX LEVEL
ODU PS MON
2-20
ROI-S03895 SYSTEM DESCRIPTION
IDU ODU
IN ODU
10/100 10/100BASE-T No.1 ODU
MODEM (No.1) INTFC RF IN/OUT (No.1)
BASE-T INTFC (SAME AS BELOW)
OUT ALM (No.1)
No.2 ODU
ODU
IN 150M INTFC/
STM-1 MODEM (No.2) INTFC RF CKT (No.2) RF IN/OUT (No.2)
OPT INTFC (No.2)
OUT ALM
No.2
MD CPU TX PWR ALM
ALM
No.1 TX INPUT ALM
MD CPU ALM CONT
RX LEVEL ALM
No.2 MODEM
No.1 MODEM APC ALM
No.2 INTERFACE
High BER ALM TERMINAL
No.1 High BER ALM ALM
No.2 DEM ALM 12 (NC)
No.1 DEM ALM RL1 25 (COM) MAINT
13 (NO)
No.2 MOD ALM
24 (NC)
No.1 MOD ALM RL2 11 (COM) PS ALM
LINK ALM 23 (NO)
COLLISION ALM 22 (NC)
CTRL RL3 9 (COM) CPU ALM
Notes: 1. The wayside applies to the 32 QAM SD (DMR)
21 (NO)
system only. E-BER (DMR) 7 (NC)
2. * Optional. SD (MUX) RL4 20 (COM) ODU ALM**
3. ** These are factory settings E-BER (MUX) 8 (NO)
5 (NC)
(default settings). These alarm MAIN INTFC LOF (DMR)
RL5 18 (COM) IDU ALM**
items can be set by the LCT. MAIN INTFC LOS (DMR) 6 (NO)
MAIN INTFC LOF (MUX) 16 (NC)
MAIN INTFC LOS (MUX) RL6 4 (COM) BER ALM**
17 (NO)
MAIN INTFC
2 (NC)
INTERFACE TERMINAL SUB INTFC LOS RL7 15 (COM) LOS**
CLUSTER ALM IN/OUT 3 (NO)
WS/ALM WS DC-DC No.1 PS ALM MAINT INTERFACE
ALM 1 3 (+) SEL V
IN 4 () INTFC*/ INTFC*/ CONV (No.1) TERMINAL
ALM 2 5 (+) ALM LAN ALM/AUX
IN 10 () INTFC* CARD* DC-DC No.2 PS ALM 11 (NC)
PNMT SEL V PWR RL8 25 (COM)
ALM 1 8 (NO) CONV (No.2) HK4 ALM**
LCT 12 (NO)
OUT 14 (COM) 23 (NC)
EOW1 ALM 2 9 (NO) RL9 10 (COM)
IDU HK3 ALM**
EOW2 OUT 15 (COM) ALM ALM 24 (NO)
8 (NC)
NE1 RL10 22 (COM) HK2 ALM**
NE2 ODU 9 (NO)
20 (NC)
PNMS V11 RL11 7 (COM) HK1 ALM**
PNMS LAN 21 (NO)
2-21/22
ROI-S03895 SYSTEM DESCRIPTION
Alarm
LED Indication on Alarm LED Indication
Equipment Alarm Initiated Initiating Alarm Condition Remote Alarm Reporting
Initiating Module on IDU
Module
MAIN INTFC LOS 150M/OPT Input STM-1 signal is lost (from MUX) ALM No.1 IDU ALM
IDU ALM1 or IDU ALM2
(MUX) INTFC (150M/OPT INTFC) and
STM-1 LOS
No.2 IDU ALM
MAIN INTFC LOF 150M/OPT Frame synchronization of input STM-1 signal (from MUX) is lost. ALM No.1 IDU ALM
(MUX) INTFC (150M/OPT INTFC) and IDU ALM1 or IDU ALM2
No.2 IDU ALM
E-BER (MUX) 150M/OPT BER is worse than preset value (10-3 to 10-5, selectable) ALM No.1 IDU ALM
INTFC (150M/OPT INTFC) and IDU ALM1 or IDU ALM2
No.2 IDU ALM
SD (MUX) 150M/OPT BER is worse than preset value (10-5 to 10-9, selectable) ALM No.1 IDU ALM
INTFC (150M/OPT INTFC) and IDU ALM1 or IDU ALM2
No.2 IDU ALM
MAIN INTFC LOS 150M/OPT Input STM-1 signal is lost (from Radio) ALM No.1 IDU ALM
(DMR) INTFC (150M/OPT INTFC) and IDU ALM1 or IDU ALM2
No.2 IDU ALM
MAIN INTFC LOF 150M/OPT Frame synchronization input STM-1 signal (from Radio) is lost ALM No.1 IDU ALM
(DMR) INTFC (150M/OPT INTFC) and IDU ALM1 or IDU ALM2
IDU No.2 IDU ALM
E-BER (DMR) 150M/OPT BER is worse than preset value of radio (10-3 to 10-5, selectable) ALM No.1 IDU ALM
INTFC (150M/OPT INTFC) and IDU ALM1 or IDU ALM2
No.2 IDU ALM
SD (DMR) 150M/OPT BER is worse than preset value of radio (10-5 to 10-9, selectable) ALM No.1 IDU ALM
INTFC (150M/OPT INTFC) and IDU ALM1 or IDU ALM2
No.2 IDU ALM
MAIN INTFC 150M/OPT 150M INTFC/OPT INTFC module failure ALM No.1 IDU ALM
IDU ALM1 or IDU ALM2
INTFC (150M/OPT INTFC) and
MAIN INTFC ALM
No.2 IDU ALM
LINK 10/100BASE-T Link of LAN (10/100BASE-T INTFC) and associated equipment is not ALM IDU ALM
IDU ALM
INTFC established (10/100BASE-T INTFC) LINK-1/2
COLLISION 10/100BASE-T Collision condition occurs COLX/DUPLEX(Blink)
COLLISION-1/2
INTFC (10/100BASE-T INTFC)
SUB INTFC WS INTFC/ WS INTFC/LAN CARD module failure ALM No.1 IDU ALM
IDU ALM1 or IDU ALM2
LAN CARD (WS INTFC/ and
SUB INTFC ALM
LAN CARD) No.2 IDU ALM
MD CPU ALM MODEM Communication between modules No.1 IDU ALM
IDU
or IDU ALM1 or IDU ALM2
(No.1/No.2)
No.2 IDU ALM
2-23/24
ROI-S03895 SYSTEM DESCRIPTION
Alarm
LED Indication on Alarm LED Indication
Equipment Alarm Initiated Initiating Alarm Condition Remote Alarm Reporting
Initiating Module on IDU
Module
2-25/26
ROI-S03895 SYSTEM DESCRIPTION
The IDU is provided with the automatic laser shutdown (ALS) function
that can be enabled or disabled. If the ALS function is enabled, the laser
output is periodically turned ON and OFF when the optical cable carrying
the STM-1 signal is disconnected inadvertently, or internationally during
maintenance. If the ALS function is disabled, the laser output is always
ON even if the optical cable is disconnected.
Fig. 2-5 shows a block diagram of the ALS function. If a fault occurs at
point A and the absence of the optical input signal in the RX 2 lasts for 550
50 msec (STM-1 LOS alarm condition), the optical signal bound for the
RX 1 (MUX equipment) from the TX 2 (OPT INTFC module) is
interrupted by a control signal generated inside the OPT INTFC module.
The MUX equipment detects the loss of signal at RX1 and the ALS
function in the MUX will, subsequently, turn off the laser output of TX1.
When the fault at point A is cleared the system can be restored by
controlling the laser output of TX2 through one of the following modes:
Automatic control
2-27
SYSTEM DESCRIPTION ROI-S03895
MUX EQUIP-
MENT OPT INTFC CTRL
RX2
A
TX1 O/E
RLOS 550 50 ms CLEAR
9010S 20.25S 2S
TIMER TX ON
TX ON TX ON
TIMER TIMER TIMER
ALS CONT
TX2 ENABLE/DISABLE
60/180/
CONT
300 sec.
DELAY
RX1 O/E
SB/DATA
DATA BUS
BUS
LCT OR PNMT
2-28
ROI-S03895 SYSTEM DESCRIPTION
MODEM TX RX MODEM
REMOTE REMOTE
CTRL CTRL
RFCOH RFCOH
MODEM RX TX MODEM
2-29
SYSTEM DESCRIPTION ROI-S03895
Even if the station is set in the MTPC mode, the opposite station is likely
to be set in the ATPC mode. Therefore, setting the RX Threshold
(Receiving threshold level) is required for controlling the transmission
level of the opposite station. Between the stations that are respectively set
in the MTPC mode, however, the setting is disabled.
STATION A STATION B
PASOLINK
+ PASOLINK
+
MTPC ATPC
(RX Threshold: 50 dBm)
2-30
ROI-S03895 SYSTEM DESCRIPTION
(ATPC)
SUBSTATION 1
(MTPC)
(ATPC) (ATPC)
SUBSTATION 5 SUBSTATION 2
A
B
MASTER
STATION
(ATPC) (ATPC)
SUBSTATION 4 SUBSTATION 3
2-31
SYSTEM DESCRIPTION ROI-S03895
The loopback function is provided for checking the system quality during
maintenance and/or to quickly isolate a fault location. The control is
performed by the LCT, the PNMT or the PNMS.
Note: In system using 10/100BASE-T INTFC module, it cannot isolate a
fault location by Loopback.
CTRL
LCT/
PNMT Note: Reverse direction is the same as above.
2-32
ROI-S03895 SYSTEM DESCRIPTION
Far-end link down control provides two kinds of functions for 10/
100BASE-T INTFC. One is to automatically stop the output from the
LAN port to alert the equipment connected with the LAN port when the
system has been disconnected by the fault in the radio section. The other is
to transmit the information for cutting the link interconnected with the
LAN port in the opposite station when the link between the LAN port and
equipment is faulty. This function can be selected by setting
Provisioning on LCT to Enable or Disable .
AUTO:Output Stop
Radio Fault
FAULT
HUB LAN LAN HUB
PASOLINK+
STM-1 STM-1
IN OUT
MUX PASOLINK+ PASOLINK+ MUX
RADIO SECTION
2-33
SYSTEM DESCRIPTION ROI-S03895
For example, at the station A, when the Pasolink+ equipment detects the
STM-1 input loss of signal (LOS) and/or loss of frame (LOF), the
information is transmitted to the station B by using RFCOH. When the
station B detects the information, Pasolink+ equipment stops the STM-1
output signal. Similarly, it is the same even if a receiving input level down
or loss of radio frame (LOF) appear in station B.
STATION A STATION B
PASOLINK+ PASOLINK+
MODEM MODEM
STM-1 STM-1 RFCOH RFCOH STM-1 STM-1
INPUT INTFC ODU ODU FSYNC INTFC OUTPUT
MUX DEMUX
INPUT
LOSS STM-1
LOF
LOS LOF
LOF RFCOH
Station A Station B
LCT
Event STM-1
LED LCT LED STM-1 Output OUTPUT
Control
STM-1 Input Loss at MAIN INTFC Shutdown *
IDU ALM Under Execution
Station A LOS (or all 1)
STM-1 Loss of MAIN INTFC Shutdown *
IDU ALM Under Execution
Frame at Station A LOF (or all 1)
Shutdown *
RX Level Down N/A ODU ALM Under Execution
(or all 1)
Loss of Radio Shutdown *
N/A IDU ALM Under Execution
Frame at Station B (or all 1)
BER Degrade
N/A IDU ALM Normal N/A
(1E-4) at Station B
2-34
ROI-S03895 SYSTEM DESCRIPTION
RFCOH
PASOLINK + PASOLINK +
PNMS PNMT
2-35
SYSTEM DESCRIPTION ROI-S03895
ODU ODU
IDU IDU
(LAN CARD) (LAN CARD)
NETWORK
Router
PC PC
WS INTFC/WS/ALM INTFC
The WS INTFC can be offered the auxiliary transmission route which
used 2.048 Mbps/1.544 Mbps of RFCOH.
There are three available interface types:
2.048 Mbps 75 ohms unbalanced
2.048 Mbps 120 ohms balanced
1.544 Mbps 100 ohms balanced
LAN Card
The LAN Card can be offered the auxiliary transmission route for an
ethernet which used following signals:
32 QAM system RFCOH of 2.048 Mbps
128 QAM system DSC or RSOH (E1/F1) of 64 K
The signal should be selected in the OH Assignment of
Provisioning.
2-36
ROI-S03895 SYSTEM DESCRIPTION
A LM 1 IN P.C . D S C ID T O U T
MUX FR A M IN G
A LM 2 IN P.C . D S C IC K IN
A LM 1 O U T RL D S C D D T IN
DEMUX FSYNC
A LM 2 O U T RL D S C D C K IN
P.C. : Photo-coupler
RL : Relay
No.1
IN HYB RX SW OUT
No.2
TX Side RX Side
2-37
SYSTEM DESCRIPTION ROI-S03895
When both the No. 1 and No. 2 channels are in normal operating
condition, the STM-1 data stream from the associated MUX equipment are
sent to the receiving end through the No. 1 and No. 2 channels. At the
receiving end, the output data streams of the No. 1 and No. 2 channels
MODEM enter the HL SW. The data signal selected by HL SW is fed to
associated MUX equipment.
At the receiving end, when the low bit error alarm (LOW BER ALM) is
detected in the MODEM of the No. 1 channel, the alarm signal is sent to
the switch control logic circuit on the CTRL module. The switch control
logic circuit send the HL SW control signal to the 150M INTFC, OPT
INTFC or 10/100BASE-T INTFC module. Then, the HL SW selects the
data signal from No.2 channel. The switching condition is shown on the
RX1 and RX2 STATUS indicators on the IDU.
2-38
ROI-S03895 SYSTEM DESCRIPTION
When both the No. 1 and No. 2 channels are in normal operating
condition, the STM-1 data signal from the associated MUX equipment are
sent to the No. 1 and No. 2 channel ODUs through the No. 1 and No. 2
channel IDUs. Here, either of the No. 1 or No. 2 channel signal is selected
at the TX switch on the ODU and fed to the receiving end. At the receiving
end, the output data signal of the No. 1 and No. 2 channels MODEM enter
the HL SW on the 150M INTFC, OPT INTFC or 10/100BASE-T INTFC
module. The data signal selected by HL SW is fed to associated MUX
equipment.
At the receiving end, when the low bit error alarm (LOW BER ALM) is
detected in the MODEM of the No. 1 channel, the alarm signal is sent to
the switch control logic circuit on the CTRL module. The switch control
logic circuit send the HL SW control signal to the 150M INTFC, OPT
INTFC or 10/100BASE-T INTFC module. Then, the HL SW selects the
data signal from No.2 channel. The switching condition is shown on the
RX1 and RX2 STATUS indicators on the IDU.
The following explains the protection switching function in the 1+1 Twin-
path and HS system.
(a) TX Switching
TX switching in HS system is accomplished by muting the TX
output power of either No.1 or No.2 channel ODU. Two types of
TX switch controls are provided: automatic switching that is
initiated by detection of a failure in the transmit section of the
MODEM or ODU, and manual switching that is initiated by the
operator using the LCT. TX switching, either initiated manually or
automatically, may cause a short interruption of the data.
Automatic and manual TX switching have the following
operational characteristics:
Switching Mode: 1. Manual switching
2. Automatic switching
Switching Priority: 1. Non-priority (Non-homing)
2. Priority No.1
2-39
SYSTEM DESCRIPTION ROI-S03895
(b) RX Switch
RX switching in 1+1 Twin-path/HS system is performed by the HL
SW on the 150M INTFC, OPT INTFC or 10/100BASE-T INTFC
module.
Two types of RX switch controls are provided: automatic
switching that is initiated by the quality deterioration of the
received signal and manual switching that is initiated by the
operator using the LCT.
The switching mode and switching priority for automatic and
manual switching are identical to those of TX switching.
However, the switching priority is only valid under automatic
switching control. This is because automatic switching is
implemented by hardware logic and manual switching is
implemented by software logic. That is, automatic switching and
manual switching are completely independent and separate
operations. Thus, when the operator reverts to automatic
switching after performing manual switching, the channel will be
re-selected by the switch control logic circuit.
Operational conditions for the automatic and manual switching are
same with those for the TX switch. System quality deterioration is
set to "LOW BER FOR RX SW" in the provisioning configuration.
Setting values are as follows (default setting is 3 10-7):
3E-6 (3X 10-6)
3E-7 (3X 10-7)
3E-8 (3X 10-8)
3E-9 (3X 10-9)
3E-10 (3X 10-10)
3E-11 (3X 10-11)
3E-12 (3X 10-12)
The power to the ODU is supplied through the coaxial cable which is also
used for the IF and other signals. The DC-DC CONV module of the ODU
produces +7/+9/+10 and 15 V DC power for the component modules
from the 43 V DC power supplied from the IDU.
2-40
ROI-S03895 SYSTEM DESCRIPTION
ODU INTFC
IF IN SEP/ SEP/COMB IF OUT
COMB FIL
IF OUT FIL IF IN
SELV
(1/3) MODEM
DC
INPUT (2/4) 43 V DC-DC +V cc
CONV
48 V/
+48 V/
+5.3 V
24 V/
DC-DC
+24 V
No. 1 CH CONV +3.6 V
2-41
ROI-S03895 SUBSYSTEM DESCRIPTION
3. SUBSYSTEM DESCRIPTION
Described herein are the composition and functional operation of each
module of the IDU and the ODU.
INDOOR UNIT
3.1 Composition
System
Location Unit/
Remarks
No.* Module Name 32 QAM 128 QAM
3-1
SUBSYSTEM DESCRIPTION ROI-S03895
3-2
ROI-S03895 SUBSYSTEM DESCRIPTION
ODU ODU
INTFC DC-DC INTFC DC-DC
MODEM CONV MODEM CONV
CTRL
3 4
(MEDIUM LAYER)
TOP VIEW
FRONT
G 7 8 9 4 M D U N IT
PW R
IF
IN /O U T
+
PWR
! WAR NING
-43V OUTPUT
TURN OFF POWER
BEFORE DISCONNECTING
IF CABLE F U SE (7 .5A ) S EL V
S C IN /O U T ALM A L M /A U X G 7 8 9 5 S W U N IT
R SW M A IN T S TATU S ALM
PNMT LCT EOW1 EO W 2 1
EO W RESET
C AL L TX RX O D U ID U
2
Note: When the IDU is used in 1+0 system, mount blank panel instead
of the MD UNIT.
Fig. 3-1 IDU Component Unit/Module Arrangement
3-3
SUBSYSTEM DESCRIPTION ROI-S03895
A block and level diagram of the IDU is shown in Fig. 3-2. Functional
operations of the IDU are described separately for the modulator section
and demodulator section.
5
10/100 ODU
10/100 IN MODEM No.2
BASE-T INTFC
BASE-T OUT INTFC (No.2) IF IN/OUT
(No.2)
1 150M 2
STM-1 INTFC/
IN OPT ODU
MODEM No.1
INTFC/ INTFC
(No.1) IF IN/OUT
STM-1 10/100 (No.1)
OUT BASE-T
4 INTFC 3
6
EOW
7
WS
WS IN INTFC/
WS OUT WS/ALM
INTFC*/**
8
9
LAN Notes:1. * Optional.
10 BASE-T CTRL
CARD* 2. ** Applies only to 32 QAM
system.
10
PNMT
11
LCT
12
EOW1
13
EOW2
14
NE1
15
NE2
16
PNMS V11
17
PNMS LAN
3-4
ROI-S03895 SUBSYSTEM DESCRIPTION
POSITION 1 2 3 4
DATA SPEED/ 155.520 Mbps 340 MHz 140 MHz 155.520 Mbps
FREQUENCY
LEVEL 8 to 28 dBm*/ 2 to 29 15 to 55 8 to 15 dBm*/
3 to 23 dBm**/ dBm**** dBm**** 7 dBm**/
1.0 Vp-p*** 1.0 Vp-p***
IMPEDANCE / /75 / /75
ohms, 50 ohms, unbalanced ohms,
unbalanced*** unbalanced***
POSITION 5 6 7,8
DATA SPEED/ 10BASE-T/ 0.3 to 3.4 kHz 1.544 Mbps/2.048 Mbps
FREQUENCY 100BASE-TX
LEVEL 6 dBm 3.0 Vo-p/2.37 Vo-p/3.0 Vo-p
IMPEDANCE 600 ohms 100 ohms, balanced/ 75 ohms,
unbalanced/ 120 ohms, balanced
POSITION 9 10 11 12
DATA SPEED/ 10 BASE-T RS-232C RS-232C 0.3 to 3.4 kHz
FREQUENCY
LEVEL 6 dBm
IMPEDANCE 600 ohms
POSITION 13 14 15 16 17
DATA SPEED/ 0.3 to 3.4 kHz RS-485 RS-485 V11 10 BASE-T
FREQUENCY
LEVEL 6 dBm
IMPEDANCE 600 ohms 100 ohms 100 ohms 100 ohms
3-5
SUBSYSTEM DESCRIPTION ROI-S03895
10/100BASE-T Interface
The 10/100BASE-T INTFC module is an interface board with two
independent bridge functions. The IEEE802.3 frame signal (10BASE-T/
100BASE-TX) received from external equipment enters the 10/100BASE-
T INTFC module. By a bridge function, the destination (media access
control (MAC) address) in the 10BASE-T/100BASE-TX signal is
identified to determine whether it is relayed. Data signal passed after this
judgment is once stored in the frame buffer circuit. Then, data stored is
read from the frame buffer circuit, and mapped* into STM-1 frame. Data
mapped is multiplexed with RSOH byte such as frame synchronization
byte, B1 parity byte, etc. to generate the STM-1 frame. STM-1 data
generated is fed to MODEM module.
3-6
ROI-S03895 SUBSYSTEM DESCRIPTION
Modulator
At the Modulator, input data signal from 150M INTFC, OPT INTFC or 10/
100BASE-T INTFC module is speed converted to give time slot for the
redundant bits such as radio frame complementary overhead (RFCOH)
and forward error correction (FEC), which are to be added in the next
stages. Then the RFCOH bits are inserted to the pre allocated slots.
RFCOH is a signal multiplexed with OW, 64k SC and SV for monitor/
control. Error correction FEC bits for the radio link are inserted, and
coded, then string-converted to obtain data stream required for
modulation. Data signal string-modulated will modulate the 340 MHz IF
signal, then fed to the ODU INTFC module.
The 140 MHz IF signal and the control signal that are contained in the
composite signal received from the ODU are separated at the MPX section
of the ODU INTFC module. After correcting for characteristic
deterioration and signal level degradation that may have been introduced
by the cable connecting the IDU and ODU, the 140 MHz IF signal is fed to
the MODEM module.
The 140 MHz IF signal from the ODU INTFC module is demodulated at
the demodulator section, then regenerates the baseband signal composed
of the radio frame. After the radio frame synchronization is established,
detection and correction of errors that may have occurred at the radio link
are performed in the error correction section. The STM-1 signal is
regenerated after separating the RFCOH bits and then fed to the 150M
INTFC, OPT INTFC or 10/100BASE-T module.
3-7
SUBSYSTEM DESCRIPTION ROI-S03895
10/100BASE-T Interface
The STM-1 signal received from the MODEM module enters the 10/
100BASE-T INTFC module. Signal received is established the STM-1
frame synchronization, and RSOH byte multiplexed in the transmit side is
detached to extract frame synchronizatiion byte and B1 parity byte. Also,
B1 parity is detected for performance monitoring in the radio link. Data
signal detached is once stored in the frame buffer circuit. Data signal read
from the frame buffer circuit is formatted to the IEEE802.3 frame signal
and output from each port.
OUTDOOR UNIT
The composition and functional operation of the ODU are described in this
chapter.
3.3 Composition
The ODU is classified into high grade (HG) and super high grade (SHG)
types. HG is used for 32 QAM system and SHG for 32/128 QAM system.
The label attached to the side of ODU indicates ODU type (see Fig. 3-3).
TRP-6G-1AA (SHG)
TRP-7G-1AA (SHG)
TRP-8G-1AA (SHG)
TRP-11G-1AA (SHG)
TRP-13G-1AA (SHG)
TRP-15G-1AA (SHG)
TRP-18G-1AA (HG) or (SHG)
TRP-23G-1AA (HG) or (SHG)
TRP-26G-1AA (HG) or (SHG)
TRP-38G-1AA (HG) or (SHG)
The component modules are arranged on the shelf as shown in Fig. 3-4.
3-8
ROI-S03895 SUBSYSTEM DESCRIPTION
PASOLINK + 0678 !
TRP-( )G-1AA ( )
OUTDOOR UNIT (SHG) TX
SUB Band TX frequency high/low
SERIAL No. DATE
WEIGHT 10kg/43V 0.9A
PASOLINK + 0678 !
TRP-( )G-1AA ( )
OUTDOOR UNIT (HG) TX
shift frequency MHz SUB band high/low
SERIAL No. DATE ,
WEIGHT 4.5kg/43V 0.5A
3-9
SUBSYSTEM DESCRIPTION ROI-S03895
DC-DC
CONV
SYNTH
DUP
CTRL
RF CKT
SYNTH
RF CKT
DC-DC
CONV
IFL FG RX LEV
MON
CONT
INSIDE OF ODU
3-10
ROI-S03895 SUBSYSTEM DESCRIPTION
RF CKT
SYNTH CONT
DC-DC
CONV
IFL FG RX LEV IF FG RX LEV
MON MON
INSIDE OF ODU
18/23/26/38 GHz ODU
3-11
ROI-S03896-05BE CONTENTS
021120
OPERATION
CONTENTS
TITLE PAGE
1 GENERAL 1-1
CL-1
ROI-S03896 GENERAL
1. GENERAL
This section provides instructions for operation of the 6/7/8/11/13/15/18/
23/26/38 GHz 150 MB digital microwave radio system.
This part describes the interface terminals and jacks, controls, indicators,
test jacks, equipment start-up and equipment shut-down. Setting and
monitoring using the LCT are required for local operation.
1-1
ROI-S03896 INTERFACE TERMINALS AND JACKS
No.1 CH No.1 CH
IF IN/OUT SEL V
PNMT LCT EOW2
EOW1 SC IN/OUT ALM ALM/AUX
G7894 MD UNIT
PWR
IF
IN/OUT
+
PWR
! WARNING
-43V OUTPUT
TURN OFF POWER
BEFORE DISCONNECTING
IF CABLE FUSE (7.5A) SEL V
NE2
WS IN/OUT STM1 IN STM1 OUT No.2 CH
No.2 CH NE1 V11 LAN
IF IN/OUT PNMS SEL V
ALTERNATE ALTERNATE
MODULE PORT1 MODULE
ALM
10BASE-T
ALM 100M 100M
PORT2
PORT1 PORT2
ALM INTFC
ALM WS IN/OUT CLUSTER ALM IN/OUT
2-1
INTERFACE TERMINALS AND JACKS ROI-S03896
RF IN/OUT
FG
IF IN/OUT
(REAR VIEW) (BOTTOM VIEW)
FG
IFL FG RX LEV
MON
IF IN/OUT
RF IN/OUT
2-2
ROI-S03896 INTERFACE TERMINALS AND JACKS
Terminal/Jack Description
2-3
INTERFACE TERMINALS AND JACKS ROI-S03896
Terminal/Jack Description
2-4
ROI-S03896 INTERFACE TERMINALS AND JACKS
Terminal/Jack Description
Pin 5 Ground
Pin 6 PNMT DTR
Pin 7 PNMT CTS
Pin 8 PNMT RTS
LCT Local craft terminal (LCT) data input/output (RS-232C)
(Modular Connector)
Pin 2 LCT TXD
Pin 3 LCT RXD
Pin 5 Ground
Pin 7 LCT CTS
Pin 8 LCT RTS
EOW1 Engineering orderwire (EOW)1 signal extension terminal for
(Modular Connector) back-to-back connection between IDUs (VF) *6
Pin 1 EXT EOW1 input (+)
Pin 2 EXT EOW1 input ()
Pin 3 EXT CALL1 input
Pin 4 EXT EOW1 output (+)
Pin 5 EXT EOW1 output ()
Pin 6 Ground
Pin 7 EXT CALL1 output
Pin 8 Ground
EOW2 EOW2 signal extension terminal for back-to-back connection
(Modular Connector) between IDUs (VF) *6
Pin 1 EXT EOW2 output (+)
Pin 2 EXT EOW2 output ()
Pin 3 EXT CALL2 output
Pin 4 EXT EOW2 input (+)
Pin 5 EXT EOW2 input ()
Pin 6 Ground
Pin 7 EXT CALL2 input
Pin 8 Ground
2-5
INTERFACE TERMINALS AND JACKS ROI-S03896
Terminal/Jack Description
2-6
ROI-S03896 INTERFACE TERMINALS AND JACKS
Terminal/Jack Description
Pin 6 NMS RD
SC IN/OUT Service channel data input/output
(D-sub Connector, 37 Pins)
Pins 1 (+) and 20 () OH1 (V.11-1) IDT
Pins 2 (+) and 21 () OH1 (V.11-1) ICK
Pins 3 (+) and 22 () OH1 (V.11-1) IFP
Pins 4 (+) and 23 () OH1 (V.11-1) DDT
Pins 5 (+) and 24 () OH1 (V.11-1) DCK
Pins 6 (+) and 25 () OH1 (V.11-1) DFP
Pins 8 (+) and 27 () OH2 (V.11-2) IDT
Pins 9 (+) and 28 () OH2 (V.11-2) ICK
Pins 10 (+) and 29 () OH2 (V.11-2) IFP
Pins 11 (+) and 30 () OH2 (V.11-2) DDT
Pins 12 (+) and 31 () OH2 (V.11-2) DCK
Pins 13 (+) and 32 () OH2 (V.11-2) DFP
Pins 15 (+) and 34 () OH3 (VF-1) input
Pins 16 (+) and 35 () OH3 (VF-1) output
Pins 17 (+) and 36 () OH4 (VF-2) input
Pins 18 (+) and 37 () OH4 (VF-2) output
Pins 7, 14, 19, 26 and 33 Ground
Note: For service channel data, insert/drop signal
waveforms and signal direction are shown in Fig. 2-5.
ALM Alarm output
(D-sub Connector, 25 Pins)
Pins 25 (COM), 12 (NC) Maintenance alarm output
and 13 (NO) RL1 Between Between
Pins 25 and 12 Pins 25 and 13
Normal state : Closed Open
Alarm state : Open Closed
Pins 11 (COM), 23 (NC) Power alarm output
and 24 (NO) RL2 Between Between
Pins 11 and 23 Pins 11 and 24
Normal state : Closed Open
Alarm state : Open Closed
2-7
INTERFACE TERMINALS AND JACKS ROI-S03896
Terminal/Jack Description
2-8
ROI-S03896 INTERFACE TERMINALS AND JACKS
Terminal/Jack Description
2-9
INTERFACE TERMINALS AND JACKS ROI-S03896
EOW1 EOW2
EOW1 EOW2
EOW1 EOW2
EOW1 EOW2
STATION B
STATION D
STATION C
STATION A
HEADSET HEADSET
HEADSET
HEADSET STATION E
STATION F
Fig. 2-4 EOW Party Line
2-10
ROI-S03896 INTERFACE TERMINALS AND JACKS
INTERFACE TERMINAL
2-11
INTERFACE TERMINALS AND JACKS ROI-S03896
ICK
IFP
IDT
PASOLINK+ ICK USER
IDU EQUIPMENT
IFP
IDT
PASOLINK+ ICK USER
IDU EQUIPMENT
IFP
DROP SIGNAL
DDT a b c d e f g h
DCK
DFP
CODIRECTIONAL INTERFACE
DDT
PASOLINK+ DCK USER
IDU EQUIPMENT
DFP
2-12
ROI-S03896 INTERFACE TERMINALS AND JACKS
Terminal/Jack Description
2-13
ROI-S03896 CONTROLS, INDICATORS AND TEST JACKS
3.1 IDU
The controls, indicators and jacks of the IDU are shown in Fig. 3-1. Their
functions are described as follows:
No.1
PWR switch
RESET
LAN CARD EOW MAINT No.1 PWR
G7894 MD UNIT
No.1 TX STATUS
PWR
ALTERNATE
No.1 RX STATUS
MODULE PWR
+
ALM ALM
STM-1 IN STM-1 OUT 2
No.2 IDU ALM
WS INTFC PASOLINK +
G7894 MDUNIT
PWR No.2 ODU ALM
+
PWR No.2 RX STATUS
FUSE (7.5A) SEL V
No.2 TX STATUS
No.2 PWR
ALM ALM R SW CALL
No.2
PWR switch
ALTERNATE
MODULE
ALM
ALM ALTERNATE
LINK MODULE
LAN CARD
COLX/DUPLEX
MEMORY OVER FLOW
ALM
CLUSTER ALM IN/OUT ALM ALM 100M 100M 100M
ALM PORT1 PORT2
100M
ALM INTFC 10/100BASE-T INTFC LINK/ACT
ALM
WS/ALM INTFC
3-1
CONTROLS, INDICATORS AND TEST JACKS ROI-S03896
(A) IDU
3-2
ROI-S03896 CONTROLS, INDICATORS AND TEST JACKS
3-3
CONTROLS, INDICATORS AND TEST JACKS ROI-S03896
IF signal from No.1 IDU is lost at No.1 ODU (No.1 ODU ALM
indicator is blink).
MAINT indicator
Lights when the maintenance ON mode is selected by the LCT.
RESET switch:
RESET switch initializes the CPU operation.
Note: When the display indication on the LCT is frozen or the
CPU is abnormal, press the RESET switch.
CALL switch:
Transmits calling signal and rings the buzzer in the opposite
station.
EOW jack:
Accesses EOW signal when headset is connected.
3-4
ROI-S03896 CONTROLS, INDICATORS AND TEST JACKS
R SW switch:
Used to go back to the previous program version after the IDU
program is updated. Slide the switch from the current position to
the other position. Then press the RESET switch.
3-5
CONTROLS, INDICATORS AND TEST JACKS ROI-S03896
COLX/DUPLEX indicator:
Lights when a setup is mode into Half Duplex mode, and collision
condition is occurred.
Note: When a setup is mode into Full Duplex mode, COLX/DUPLEX
indicator is always turned on.
LINK/ACT indicator:
Lights when the 10/100BASE-T and associated equipment is linked.
Note: Blinks when the data is transmitted.
3.2 ODU
The controls, indicators and test jacks of the ODU are shown in Fig. 3-2.
IFL FG RX LEV
MON
RX LEV MON:
Gives access to the receiving level monitoring voltage.
Provided for transmission of OW signal between IDU and ODU
when the OW/RX LEV Monitor and headset is connected.
3-6
ROI-S03896 CONTROLS, INDICATORS AND TEST JACKS
The X0818A OW/RX LEV Monitor (optional) is used for operation and
maintenance and is shown in Fig. 3-3. The operation range of the OW/RX
LEV Monitor is 0 C to +45 C. The function of the controls/interface of
the OW/RX LEV Monitor are described as follows:
METER:
Indicates receiving RF level monitoring voltage.
OW indicator:
Lights when OW communication is performed (The OW ON-OFF
switch is set to ON). When the OW indicator is not lit even though
OW switch is set to ON, replace the battery (6F22(UB)/9V) since the
battery had become weak.
OW ON-OFF switch:
Enables to transmission of OW signal between IDU and ODU.
VOL control:
Adjusts receive OW voice level.
RX LEV/OW IN:
Input connector for the RX LEV monitoring voltage and OW signal.
HEADSET jack:
Permits communication between IDU and ODU when orderwire
headset is connected.
3-7
CONTROLS, INDICATORS AND TEST JACKS ROI-S03896
2 3
1 4
0 5 METER
OW SWITCH
PASOLINK OW INDICATOR
ANTENNA POINTING MONITOR
ON OFF
OW
OW
VOL CONTROL
VOL
BATTERY
(6F22(UB)/9V)
RX LEV/OW IN JACK
HEADSET JACK
RX LEV/OW IN
HEADSET
Fig. 3-3 Controls, Indicators and Test Jacks of OW/RX LEV Monitor
3-8
8 pages
ROI-S03896 LAN CABLE SELECTION (OPTIONAL)
FRONT
10BASE-T CONNECTOR
MDI
MDI-X
LAN CARD
Selection for LAN cable When a straight cable is In case of straight cable is used, set
connected to the 10BASE-T MDI-MDI-X switch to:
connector on the LAN Card, SET POSITION
switch is set to MDI position. HUB and Router MDI
PC MDI-X
When a cross cable is In case of cross cable is used, set
connected to the 10BASE-T MDI-MDI switch to:
connector on the LAN Card, SET POSITION
switch is set to MDI-X HUB and Router MDI-X
position. PC MDI
4-1
ROI-S03896 EQUIPMENT START-UP AND SHUT-DOWN
5.1 Start-up
This procedure describes how to turn the power on/off after the initial
lineup is completed and the configuration of frequency and transmit
output level is also completed.
Apparatus:
Suitable Screwdriver
Digital Multimeter
Step Procedure
1 Check that the IF cable between the IDU and the ODU is
connected,
5-1
EQUIPMENT START-UP AND SHUT-DOWN ROI-S03896
No.1
PWR SWITCH No.1 PWR
G7894 MD UNIT
PWR
IF
IN/OUT
+
PWR
! WARNING
-43V OUTPUT
TURN OFF POWER
BEFORE DISCONNECTING
IF CABLE FUSE (7.5A) SEL V
5.2 Shut-down
Step Procedure
1 Turn off the PWR switch on the front of the IDU (see Fig. 5-1).
5-2
2 pages
ROI-S03896 SETTING AND MONITORING IN LCT
6.1 General
6-1
SETTING AND MONITORING IN LCT ROI-S03896
The password can be changed when Admin level is logged in. For
procedures to change the password, refer to the Appendix in Maintenance
section.
6-2
ROI-S03896 SETTING AND MONITORING IN LCT
(Logout)
Alarm/Status
Performance Monitor Display Metering/BER
15 min Register/DMR
15 min Register/MUX
1 day Register/DMR
1 day Register/MUX
15 min Register/DMR
OFS Occur
OFS Recover
BBE Occur
BBE Recover
ES Occur
ES Recover
SES Occur
SES Recover
UAS Occur
UAS Recover
15 min Register/MUX
OFS Occur
OFS Recover
BBE Occur
BBE Recover
ES Occur
ES Recover
SES Occur
SES Recover
UAS Occur
AA A B UAS Recover
6-3
SETTING AND MONITORING IN LCT ROI-S03896
AA A B
1 day Register/DMR
OFS Occur
OFS Recover
BBE Occur
BBE Recover
ES Occur
ES Recover
SES Occur
SES Recover
UAS Occur
UAS Recover
1 day Register/MUX
OFS Occur
OFS Recover
BBE Occur
BBE Recover
ES Occur
ES Recover
SES Occur
SES Recover
UAS Occur
UAS Recover
RSL Monitor
Provisioning Data
Display Current Data
Set Provisioning Data
ALS
Enable/Disable
ALS Delay Time
BB C
6-4
ROI-S03896 SETTING AND MONITORING IN LCT
BB C
BER Threshold
High BER (Radio)
Low BER (Radio)
E- BER (DMR)
SD (DMR)
E- BER (MUX)
SD (MUX)
Sub Interface
Wayside*
Wayside*/Cluster Alarm
Cluster Alarm
10BASE-T
Not used
OH Assignment
Easy
Customize
MTPC TX PWR
ATPC Range
ATPC MAXIMUM PWR
ATPC MINIMUM PWR
RX Threshold
Additional ATT
ODU ALM Mode
TX SW Priority
RX SW Priority
MS-AIS Generation
10/100BASE-T
CC
6-5
SETTING AND MONITORING IN LCT ROI-S03896
CC
System Configuration
Equipment Configuration
RF Frequency
TX Power Control
Frame ID
Main Interface
Inventory Data
DD D
6-6
ROI-S03898-05AE CONTENTS
030408
MAINTENANCE
CONTENTS
TITLE PAGE
1. GENERAL 1-1
2. PRECAUTIONS 2-1
CL-1
ROI-S03898 GENERAL
1. GENERAL
This section provides instructions for the maintenance of the 6/7/8/11/13/
15/18/23/26/38 GHz 150 MB digital microwave radio system.
1-1
ROI-S03898 PRECAUTIONS
2. PRECAUTIONS
The following precautions must be carefully observed during
maintenance.
2-1
PRECAUTIONS ROI-S03898
(g) When the control such as TX MUTE, CW, LB, etc. is performed,
set TX SW and RX SW to the same channel certainly. If it carries
out in AUTO condition, it may not operate normally.
(i) Before removing or installing the IDU/ODU, turn off the power
switch on the IDU.
G7894 MD UNIT
PWR
IF
IN/OUT
+
PWR
! WARNING
-43V OUTPUT
TURN OFF POWER
BEFORE DISCONNECTING
IF CABLE FUSE (7.5A) SEL V
G FRONT VIEW
IDU
2-2
ROI-S03898 PRECAUTIONS
Step Procedure
1 Connect the RS-232C cable between the LCT and the IDU,
G7894 MD UNIT
PWR
IF
IN/OUT
+
PWR
! WARNING
-43V OUTPUT
TURN OFF POWER
BEFORE DISCONNECTING
IF CABLE FUSE (7.5A) SEL V
RS-232C
CABLE
LCT
2-3
PRECAUTIONS ROI-S03898
Step Procedure
Login : Admin
Password : ********
Enter Selection : 7
2-4
ROI-S03898 PRECAUTIONS
Step Procedure
2-5
PRECAUTIONS ROI-S03898
Step Procedure
Login : Admin
Password : ********
7. Maintenance
Enter Selection : 7
2-6
ROI-S03898 PRECAUTIONS
Step Procedure
Enter Selection : 2
9 Press the desired item No. and press the Enter key. Set
the TX SW and/or RX SW to desired No.1, No.2 or
Auto position according to display indication,
2-7
ROI-S03898 TEST SETS AND ACCESSORIES
3-1
TEST SETS AND ACCESSORIES ROI-S03898
3-2
ROI-S03898 TEST SETS AND ACCESSORIES
3-3
TEST SETS AND ACCESSORIES ROI-S03898
IDU SIDE
LCT LCT CONNECTOR
SIGNAL PIN PIN SIGNAL
NAME No. No. NAME
CTS 8 8 RTS
RTS 7 7 CTS
DTR 6 6 DTR
GND 5 5 GND
DSR 4 4 DSR
TXD 3 3 RXD
RXD 2 2 TXD
DCD 1 1 CD
3-4
4 pages
ROI-S03898 PREVENTIVE MAINTENANCE
4. PREVENTIVE MAINTENANCE
This chapter provides the routine (annual) maintenance procedures to
ensure the satisfactory operation of the equipment. During preventive
maintenance, carefully observe the precautions given in chapter 2.
Step Procedure
1 Connect the RS-232C cable between the LCT and IDU (see
Fig. 2-2 in Chart 2-1),
3 Enter Login name User and press the Enter key on the
LCT,
Login : User
4-1
PREVENTIVE MAINTENANCE ROI-S03898
Step Procedure
5 Press the 1 key for Display Metering /BER and press the
Enter key. Verify the all items listed in Table 4-1.
Notes: 1. The left side results are for No.1 channel and right side for
No.2 channel.
2. 3.0E-4 indication indicates the 3 x 10-4 bit error rate.
3. * BER (radio BER) is calculated every one minute.
Calculating is displayed till the value is fixed.
4. TX POWER/RX LEVEL is indicated in 1 dB step.
5. The range of RX LEVEL which can be displayed is as follows:
32 QAM:15 to 84 dBm
128 QAM:15 to 75 dBm
4-2
ROI-S03898 PREVENTIVE MAINTENANCE
Step Procedure
4-3
PREVENTIVE MAINTENANCE ROI-S03898
Step Procedure
CH Select (1-16) : 8
15min Register/CH-8
Time Stamp | Status | OFS | BBE | ES | SES | UAS
-------------------------------------------------------------------------------------------------------
2001/01/01 00:15 | Invalid | + 12 | + 34567 | + 890 | + 12 | 34
2001/01/01 00:30 | Valid | 5 | + 6789 | 12 | 3 | 4
4-4
ROI-S03898 PREVENTIVE MAINTENANCE
Step Procedure
4-5
PREVENTIVE MAINTENANCE ROI-S03898
Step Procedure
10 Press the 3 key for Display Threshold Data and press the
Enter key,
11 Press the 5 key for RSL Monitor and press the ENTER
key,
4-6
ROI-S03898 PREVENTIVE MAINTENANCE
Step Procedure
4-7
ROI-S03898 CORRECTIVE MAINTENANCE
5. CORRECTIVE MAINTENANCE
Corrective maintenance done in the field is described in this chapter.
Corrective maintenance in the field covers fault isolation, module/unit
replacement and alignment. The fault location procedures describes how
to isolate module-level/unit-level faults.
The faults that cause deterioration in the transmission quality are primarily
originated by changes occurred in the state of propagation. Therefore, if a
decline in the transmission quality or similar fault takes place frequently,
the link design will have to be reviewed.
The following 3 methods are available for checking the details of a fault:
Meter readings
Loopback.
5-1
CORRECTIVE MAINTENANCE ROI-S03898
(c) Loopback
When there is an interruption of signals, use the STM/SONET
analyzers and isolate the faulty part by checking the passage of the
STM-1 signal by loopback. Locate the fault by using the
following diagrams.
Enter Selection : 2
5-2
ROI-S03898 CORRECTIVE MAINTENANCE
Control
Control items can be selected only under maintenance mode. As this
Control is likely to cause disconnection of signal, take care during
operation.
RF Frequency
Sets the transmitting and receiving RF frequencies.
TX mute
Turns off/disables the transmitter output.
CW
Used for outputting a clean carrier wave (CW). Used to confirm the
transmitting output power and frequency stability.
IF loopback
Used for localizing equipment failure to ODU or IDU. The input
STM-1 signal from MUX is looped back at IF stage. If no
abnormality is found in the signal after IF loopback, it is assumed that
the ODU has a problem.
5-3
CORRECTIVE MAINTENANCE ROI-S03898
4.5
3.5
3
RX LEVEL MON[V]
2.5
1.5
0.5
0
-80 -70 -60 -50 -40 -30 -20
RX INPUT LEVEL[dBm]
5-4
ROI-S03898 CORRECTIVE MAINTENANCE
Meter Reading
Fault
Condition
Isolation
TX Power RX Level ODU PS MON
1 ODU
Path propagation or
2
ODU
DC-DC CONV module
3 on MD UNIT of IDU or
IF cable
Step Procedure
1 Connect the RS-232C cable between the LCT and IDU (see
Fig. 2-2 in Chart 2-1),
3 Enter Login name User and press the Enter key on the
LCT,
Login : User
5-5
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
Enter Selection : 1
5-6
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
Notes: 1. The left side status indication is for No. 1 channel and right
side for No.2 channel.
2. *1 When an Alarm indication is displayed, the ODU has a
failure.
3. *2 When an Alarm indication is displayed, the MD UNIT
in the IDU has a failure.
4. *3 When an Alarm indication is displayed, the SW UNIT
has a failure.
5. *4 When an Alarm indication is displayed, the 150M
INTFC/OPT INTFC module has a failure.
6. *5 When an Alarm indication is displayed, the LAN
CARD/WS INTFC module is failure.
7. The alarm and status indication items displayed depends on
the system configuration.
The alarm and status of each module and ODU are displayed.
Each items is explained below.
5-7
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
5-8
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
SUB INTFC LOS: Indicates the status of the SUB INTFC input
signal. If the input is disconnected, this
alarm is issued.
5-9
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
5-10
ROI-S03898 CORRECTIVE MAINTENANCE
Apparatus:
STM/SONET Analyzer
Optical Variable Attenuator
Step Procedure
A. ELECTRICAL INTERFACE
B. OPTICAL INTERFACE
5-11
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
8 Repeat step 4.
OPTICAL
VARIABLE
ATTENUATOR* STM/SONET
ANALYZER
IDU
5-12
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
A. PREPARATION
1 Connect the RS-232C cable between the LCT and IDU (see
Fig. 2-2 in Chart 2-1),
Login : Admin
Password : ********
5-13
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
Enter Selection : 7
6 Press the 1 key for MAINT Mode and press the Enter
key,
B. IF LOOPBACK CONTROL
5-14
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
10 Press the 7 key for IF loopback and press the Enter key,
Enter Selection : 2
Success !!
14 After the Loopback test for BER, press the 7 key and
press the Enter key,
5-15
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
16 Press the 2 key for OFF and press the Enter key,
Enter Selection : 2
Success !!
5-16
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
22 After the Loopback test for BER, press the 8 key and
press the Enter key,
23 Press the 2 key for OFF and press the Enter key,
25 Press the 9 key for STM-1 Loopback (Far End) and press
the Enter key,
Enter Selection : 2
Success !!
5-17
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
28 After the Loopback test for BER, press the 9 key and
press the Enter key,
29 Press the 2 key for OFF and press the Enter key,
5.2 Replacement
The procedures for replacing IDU/module with spare are given in the
Chart 5-4.
The procedures for replacing the ODU with a spare are given in Chart 5-5.
The label attached to the side of ODU indicates the ODU type (see Fig
5-3). To replace the ODU, prepare another ODU of the same type as
indicated on the label of the failed one. (see 3.3 (Composition) 2.3 in
Description section)
5-18
ROI-S03898 CORRECTIVE MAINTENANCE
PASOLINK + 0678 !
TRP-( )G-1AA ( )
OUTDOOR UNIT (SHG) TX
SUB Band TX frequency high/low
SERIAL No. DATE
WEIGHT 10kg/43V 0.9A
PASOLINK + 0678 !
TRP-( )G-1AA ( )
OUTDOOR UNIT (HG) TX
shift frequency MHz SUB band high/low
SERIAL No. DATE ,
WEIGHT 4.5kg/43V 0.5A
Note: The HG type is used for 32 QAM system and the SHG type
for 32 and 128 QAM system.
5-19
CORRECTIVE MAINTENANCE ROI-S03898
Apparatus:
Suitable Screwdriver
Step Procedure
A. MODULE REPLACEMENT
REMOVING
5-20
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
MOUNTING
SCREW 2 SCREW 1
G7894 MD UNIT
PWR
IF
IN/OUT
+
PWR
! WARNING
-43V OUTPUT
TURN OFF POWER
BEFORE DISCONNECTING
IF CABLE FUSE (7.5A) SEL V
FRONT VIEW
5-21
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
B. IDU REPLACEMENT
REMOVING
REMOUNTING
5-22
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
REMOVING
REMOUNTING
SW UNIT REPLACEMENT
REMOVING
5-23
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
REMOUNTING
5-24
ROI-S03898 CORRECTIVE MAINTENANCE
No.1 CH No.1 CH
SCREW No.1 CH MD UNIT PWR SWITCH SEL V SCREW
G7894 MD UNIT
PWR
IF
IN/OUT
+
PWR
! WARNING
-43V OUTPUT
TURN OFF POWER
BEFORE DISCONNECTING
IF CABLE FUSE (7.5A) SEL V
G7894 MD UNIT
PWR
IF
IN/OUT
+
PWR
! WARNING
-43V OUTPUT
TURN OFF POWER
BEFORE DISCONNECTING
IF CABLE FUSE (7.5A) SEL V
5-25
CORRECTIVE MAINTENANCE ROI-S03898
Apparatus:
T type hexagonal driver
Step Procedure
REMOVING
5 Loosen the six bolts fixing the ODU with a T type hexagonal
driver,
MOUNTING
5-26
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
1 3
5 6
4 2
5-27
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
RF IN/OUT
CABLE
IF IN/OUT
CABLE
ODU
SELF-BONDING TAPE
5-28
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
REMOVING
SCREWS
SCREWS
MOUNTING
5-29
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
GUIDE PIN
5-30
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
GUIDE PIN
UP
UP
V POLARIZATION H POLARIZATION
V/H Polarization Conversion
5-31
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
26 Mount the spare ODU onto the bracket, and tighten the four
screws on the ODU,
SCREWS
ODU
SCREWS
5-32
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
IF CABLE
ODU
SELF-BONDING TAPE
ODU
IF CABLE
SELF-BONDING TAPE
IN CASE OF L ANGLE
5-33
CORRECTIVE MAINTENANCE ROI-S03898
5.3 Alignment
5-34
ROI-S03898 CORRECTIVE MAINTENANCE
Login : Admin
Password : ********
5-35
CORRECTIVE MAINTENANCE ROI-S03898
This chart describes the procedure for setting the system configuration.
The items to be set are as follows:
Equipment Configuration
RF Frequency
TX Power Control
Frame ID
Main Interface
Step Procedure
Login : Admin
Password : ********
5-36
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
Enter Selection : 4
5-37
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
5-38
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
9 After setting, press the Enter key for setting the Frame
ID,
5-39
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
10 After setting, press the Enter key for setting the Main
Interface,
5-40
ROI-S03898 CORRECTIVE MAINTENANCE
This chart describes the procedure for setting date and time. When the
IDU is turned off for an extended period (i.e. approx. 1 week), the
equipment time setting could have been cleared. In such case, verify and
re-enter the time setting after turning on the IDU.
Step Procedure
Enter Selection : 7
Success !!
3 Press the 4 key for setting the Set Calendar and press the
Enter key,
5-41
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
5-42
ROI-S03898 CORRECTIVE MAINTENANCE
This chart describes the procedure for setting the provisioning data.
Setting items are as follows:
ALS
BER Threshold
Sub Interface
OH Assignment
MTPC TX PWR
ATPC Range
RX Threshold
Additional ATT
ODU ALM MODE
TX SW Priority
RX SW Priority
MS-AIS Generation
10/100BASE-T
Step Procedure
5-43
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
Factory Setting
Item
32 QAM System 128 QAM System
5-44
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
Factory Setting
Item
32 QAM System 128 QAM System
5-45
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
4 Press the 3 key for setting the ALS and press the Enter
key,
6 Press the 4 key for setting the BER Threshold and press
the Enter key,
5-46
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
Low BER for RXSW : Sets the threshold level for the signal
degrade (SD) alarm of Radio section.
Used for RX SW switchover
condition in the 1+1 mode. There are
seven settable threshold values;
3x10-6, 3x10-7, 3x10-8, 3x10-9, 3x10-
10
, 3x10-11 and 3x10-12.
E-BER (DMR) : Sets the threshold level for the Excessive-
BER alarm of the Radio section. Sets the
threshold level of BER after switchover of
RX SW in 1+1 mode. There are three
settable threshold values;
1x10-3, 1x10-4 and 1x10-5.
SD (DMR) : Sets the threshold level for the signal degrade
(SD) alarm of the Radio section. Sets the
threshold level of BER after switchover of RX
SW in 1+1 mode. There are four settable
threshold values;
1x10-6, 1x10-7, 1x10-8 and 1x10-9.
E-BER (MUX) : Sets the threshold level for the Excessive-
BER alarm of the input STM-1 signal from
MUX section. There are three settable
threshold values;
1x10-3, 1x10-4 and 1x10-5.
SD (MUX) : Sets the threshold level for the signal degrade
(SD) alarm of the input STM-1 signal from
MUX section. There are four settable threshold
values;
1x10-6, 1x10-7, 1x10-8 and 1x10-9.
5-47
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
8 Press the 5 key for setting the Sub Interface and press the
Enter key,
5-48
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
5-49
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
12 Press the 7 key for setting the MTPC TX PWR and press
the Enter key,
14 Press the 8 key for setting the ATPC Range and press the
Enter key,
5-50
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
-55 dBm
5 dB
RX LEVEL
(ATPC
HYSTERESIS)
-60 dBm
(RX THRESHOLD
LEVEL)
--- RX Threshold---
Current (-70 to -30dBm) : -55
Enter Selection ([RET] = No Change) :
5-51
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
20 Press the 1, 2 key for setting the ODU ALM Mode and
press the Enter key,
5-52
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
5-53
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
5-54
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
Note: For port 1/port 2 setting, a setup is the same as the equipment
connected as shown in table below. In Auto negotiation mode,
the MDI or MDI-X is selected automatically. When the Network
port is fixed, it is set to MDI.
EXTERNAL EQUIPMENT
100BASE-TX/Half Duplex
100BASE-TX/Half (FIX)
10BASE-T/Half Duplex
10BASE-T/Full Duplex
10BASE-T/Half (FIX)
Auto Negotiation
IDU PORT
SETTING POSITION
5-55
CORRECTIVE MAINTENANCE ROI-S03898
This chart describes the procedure for setting the parallel alarm output and
the status of House Keeping.
Step Procedure
Enter Selection : 6
5-56
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
Relay Configuration
A maximum of 11 relays can be defined to provide parallel
alarm outputs. The alarms that would cause RL1 to RL3 to
be triggered are pre-assigned while the alarms that would
cause RL4 to RL11 to be triggered can be selected for each
relay. It is also possible to define RL8 to RL11 as HK CONT
outputs instead of alarm outputs as shown in the table below.
If RL8 to RL11 are not assigned as HK CONT outputs, they
may be used as alarm outputs (see Table 2-2, chapter 2 in
Operation section). As shown in Table 2-2 (chapter 2 in
Operation section), more than one alarm may be assigned to
each relay.
NC
COM
NO
(FORM-C)
5-57
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
RL01 RL02 RL03 RL04 RL05 RL06 RL07 RL08 RL09 RL10 RL11
MAINT Out Mask Mask Mask Mask Mask Mask HK HK HK HK
PS ALM - Out - - - - - HK HK HK HK
CPU ALM - - Out - - - - HK HK HK HK
8. ODU ALM1 - - - Out - - - HK HK HK HK
9. ODU ALM2 - - - Out - - - HK HK HK HK
10. IDU ALM1 - - - - Out - - HK HK HK HK
11. IDU ALM2 - - - - Out - - HK HK HK HK
Enter Selection([RET]=No Change):
5-58
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
Output Control
This function can be used to remotely control external
apparatus in the station (e.g. A/C on/off).
CONT Off:
COM and NC terminals of relay are connected.
CONT On:
COM and NO terminals of relay are connected.
5-59
CORRECTIVE MAINTENANCE ROI-S03898
Apparatus:
SDH/SONET Analyzer
Optical Variable Attenuator
Step Procedure
Electrical Interface
Optical Interface
5-60
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
10 Repeat step 4,
12 Repeat step 5 to 7.
5-61
CORRECTIVE MAINTENANCE ROI-S03898
TRANSMITTING END
OPTICAL STM/SONET
VARIABLE ANALYZER
150M INTFC/ ATTENUATOR *
OPT INTFC
STM1 IN
G7894 MD UNIT
PWR
IF
IN/OUT
+
PWR
! WARNING
-43V OUTPUT
TURN OFF POWER
BEFORE DISCONNECTING
IF CABLE FUSE (7.5A) SEL V
IDU
RECEIVING END
STM/SONET
150M INTFC/ ANALYZER
OPT INTFC
STM1 OUT
G7894 MD UNIT
PWR
IF
IN/OUT
+
PWR
! WARNING
-43V OUTPUT
TURN OFF POWER
BEFORE DISCONNECTING
IF CABLE FUSE (7.5A) SEL V
IDU
5-62
ROI-S03898 CORRECTIVE MAINTENANCE
Login : Admin
Password : ********
Step Procedure
A. PREPARATION
5-63
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
Login : Admin
Password : ********
5 Press the 5 key for Inventory Data and press the Enter
key,
5-64
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
6 Press the 1 key for Inventory Data and press the Enter
key,
5-65
CORRECTIVE MAINTENANCE ROI-S03898
Step Procedure
SW UNIT Setting
10 Press the 3 key for setting the SW UNIT press the Enter
key,
Success !!
11 Enter Code No. of the SW UNIT and press the Enter key,
13 Enter Serial No. and press the Enter key. Press the Y
key, then Success!! is displayed,
5-66
ROI-S03898 CORRECTIVE MAINTENANCE
Step Procedure
MD UNIT Setting
19 Press the 4 key for setting the MD UNIT and press the
Enter key,
Success !!
21 Enter Code No. of the MD UNIT and press the Enter key,
5-67
ROI-S03898 MOUNTING OF OPTIONAL MODULES
6. MOUNTING OF OPTIONAL
MODULES
This chapter explains the mounting of optional modules.
It is not necessary to turn off the equipment before mounting the optional
modules.
6.1 Mounting
Apparatus:
Screwdriver
Step Procedure
3 Hold the two screws with both hands, and remove the blank
panel,
6-1
MOUNTING OF OPTIONAL MODULES ROI-S03898
Step Procedure
6.2 Setting
After mounting the optional modules, it is necessary to set the provisioning
data. The LAN CARD and WS INTFC module settings are as follows:
(a) LAN CARD
Sub Interface item of Provisioning Setting in Chart 5-8
should be set.
Using customize in the OH Assignment, DSC1 to 4, E1 (DMR)
or F1 (DMR) can be assigned for the LAN Card. Make sure that
the same assignment is used in the opposite station.
6-2
2 pages
ROI-S03898 APPENDIX
APPENDIX
CHANGES OF PASSWORD
1. General
2. Procedure
Step Procedure
Login : Admin
Password : ********
A-1
APPENDIX ROI-S03898
Step Procedure
Enter Selection : 7
A-2
2 pages
ROI-S04215-051E APPENDIX
020402
APPENDIX
PROCEDURES FOR SYSTEM
CHANGING FROM 1+0 SYSTEM TO
1+1 SYSTEM/1+1 SYSTEM TO 1+0
SYSTEM OF PASOLINK +
1. GENERAL
STM-1/1+1 System
MDP-150MB5T-3
MDP-150MB7T-1
PDH/1+1 System
MDP-17MB4T-2A
MDP-34MB4T-2A
MDP-34MB4T-2B
2. PROCEDURES
TOOLS
A-1
APPENDIX ROI-S04215
Step Procedure
+
PASO LIN K
A-2
ROI-S04215 APPENDIX
Step Procedure
7 Loosen two screws on the IDU and remove the blank panel,
PASOLIN K + SCREW
SCREW
BLANK
PANEL
IF IN/OUT
MD SEL V
UNIT
A-3
APPENDIX ROI-S04215
Step Procedure
10 Turn on the power supply for the No.1 and No.2 channels of
the IDU,
A-4
ROI-S04215 APPENDIX
Step Procedure
4 Loosen two screws on the IDU and remove the blank panel,
PASOLINK
+ SCREW
SCREW
BLANK
PANEL
A-5
APPENDIX ROI-S04215
Step Procedure
IF IN/OUT
MD UNIT SEL V
(No.2 CH)
7 Turn on the power supply for the No.2 channels of the IDU,
A-6
ROI-S04215 APPENDIX
Step Procedure
REGULAR CHANNEL 1
PWR
IF IN/OUT
SWITCH
(No.1 CH)
+
PWR
SWITCH
PA SOLIN K + (No.2 CH)
SCREW +
SCREW
MD UNIT
(No.2 CH)
A-7
APPENDIX ROI-S04215
Step Procedure
6 Mount blank panel onto equipment shelf and tighten the two
screws,
PASOLIN K + SCREW
SCREW
BLANK
PANEL
REGULAR CHANNEL 2
A-8
ROI-S04215 APPENDIX
Step Procedure
BLANK PANEL
SCREW
PAS OLIN K +
SW UNIT
IF IN/OUT SEL V
SCREW
SCREW +
MD UNIT
PASO LIN K +
A-9
APPENDIX ROI-S04215
Step Procedure
A-10
ROI-S04215 APPENDIX
Step Procedure
PWR
IF IN/OUT
SWITCH
(No.1 CH)
+
PWR
SWITCH
PA SOLIN K + (No.2 CH)
SCREW +
SCREW
MD UNIT
(No.2 CH)
A-11
APPENDIX ROI-S04215
Step Procedure
6 Mount the blank panel onto equipment shelf and tighten the
two screws, if required,
PASOLIN K + SCREW
SCREW
BLANK
PANEL
A-12
12 pages
APPENDIX ROI-S04077
Table A-28 18 GHz Band, Relationship of Sub-band and Radio Frequency PORTARIA 1288
A-10