7/95 4.3.051.01
QM/33, QM/34
Alternative Switches
Symbol Switches (without LED) Symbol Switches (with LED) Description
TQM/33/* High temperature (+150 C), silicone cable (2 m length)
brown
blue
+ brown
~ QM/34/S/* PVC cable (2, 5 or 10 m length), switching voltage
10 to 240 V a.c./d.c., switching current 500 mA,
blue switching power 50 W/ 50 VA, switching time 2 ms
~
(Output) QM/34/S/*/PU Polyurethane cable (2 m length), cable type 2 x 0,5
* Insert cable length
1,5 250
50 W 200 3W
50 VA 3 VA
1,0
150
100
0,5
50
A QM/34 A QM/34/S
25 W
1 0,5
0,8 0,4 50 W
50 VA
0,6 0,3
0,4 0,2
0,2 0,1
A TQM/33 50 W
50 VA
1,5
1,0
0,5
0 Va.c. / d.c.
10 20 30 33
4.3.051.02 7/95
QM/33, QM/34
Basic Dimensions
QM/33 QM/34 QM/34/P View A
15,5
1 4
LED 35 4,5
3
A
8
8
10
5,8
24
35 35 LED
1
3,5
6
Brackets for round line cylinders
RM/8000/M, RM/28000/M
7/95 4.3.051.03
QM/33, QM/34
A
B
Magnetically operated switch
RA/8000/M, RA/28000/M
Model QM/27/2/1 QM/27/2/1 QM/27/2/1 QM/27/2/1 QM/27/2/1 QM/27/2/1 QM/27/2/1 QM/27/2/1 QM/27/2/1
mm 32 40 50 63 80 100 125 160 200
A 9 8 7 7 7 2 -4 -10 -17
B 7 8 5 7 4 2 -3 -9 -14
RM/900/M
Model QM/27/2/1 QM/27/2/1 QM/27/2/1 QM/27/2/1 QM/27/2/1 QM/27/2/1
inch 1 1/4 1 3/4 2 2 1/2 3 4
A 9 8 7 7 4 2
B 8 7 6 7 4 2
PRA/8000/M, PRA/28000/M
Model QM/33/P32/22 QM/33/P32/22 QM/33/P32/22 QM/33/P32/22 QM/33/P32/22 QM/33/P32/22
mm 32 40 50 63 80 100
B 5,5 6,5 5,5 6,5 3,5 1,5
To order cover
separately
20
M/46000/M
Model (bracket) QM/33/732/22 QM/33/732/22 QM/33/732/22 QM/33/732/22 QM/33/732/22
Model (cover) M/P34899/1/** M/P34899/1/** M/P34899/1/** M/P34899/2/** M/P34899/2/**
mm 32 40 50 63 80
B 10 9 9 9 9
C 14,5 13,5 13,5 13,5 13,5
Note: For stroke > 500 mm an additional bracket mounting (Type: QM/33/732/22) has to be ordered for every extra 250 mm. ** Insert stroke length (mm)
Warning
These products are intended for use in industrial control systems only. The system designer is warned to consider the failure modes of all
Do not use these products where voltage, current and temperatures component parts used in control systems and to provide adequate
can exceed those listed under Technical Data. safeguards to prevent personal injury or damage to equipment in the
event of such failure.
Before using these products for non-industrial applications, life- System designers must provide a warning to end users in the
support systems, or other applications not within published specifi- system instructional manual if protection against a failure mode
cations, consult NORGREN. cannot be adequately provided.
System designers and end users are cautioned to review specific
Through misuse, age, or malfunction, components used in control sys- warnings found in instruction sheets packed and shipped with these
tems can fail in various modes. products.
4.3.051.04 7/95