GTP-1

(to be filled in and signed by the tenderer)


GUARANTEED TECHNICAL PARTICULARS AND DETAILS FOR POWER TRANSFORMERS

Sr. Particulars/Details required to be


No given by the tenderer
1. Name of the Manufacturer
2. Normal full load three phase output with
temperature rise as specified in the
Specification.
H.V. Winding (KVA)
L.V. Winding (KVA)
3. Continuous three phase output under
site conditions as specified in the
Specification (after supplying derating
factor, if any)
H.V. Winding (KVA)
L.V. Winding (KVA)
4. Type of cooling and corresponding
normal full load output
H.V. Winding (KVA)
L.V. Winding (KVA)
5. Overload capacity (for 2 hrs) starting
from full load and with temperature as
specified in the Specification (KVA)
6. Normal ratio of transformation
7. Connections : (including vector group
reference No. & symbol
a) High voltage winding
b) Low voltage winding
8. Type of Tap changer
9. Tappings
a) Number
b) Range
c) Location

10. Type of core construction


ii) Temperature rise in oil by
thermometer.
iii) Hot spot temperature over Specified
ambient temperature (Deg.C.)
12. Limit for hot spot temperature for which
the transformer is designed (Deg. C)
13. i) Guaranteed no load loss at normal
ratio, rated frequency at 75 Deg. C
average winding temperature KW.
ii) Tolerance, if any applicable to above
14. i) Guaranteed total losses at normal
ratio, rated output rated voltage
dated frequency at 75 Deg. C average
including auxiliary losses at rated
output-KW
ii) Tolerance, if any applicable to above
15. Auxiliary losses at rated putout included
in 14(i) above.
15. Total losses at normal ratio, rated
(A) output, rated voltage, rated frequency
and maximum attainable temperature at
site including auxiliary losses KW.
16 Earthing current and power factor (L.V.
side)
i) At normal voltage and frequency.
ii) At maximum voltage and normal,
frequency (110%)
17. Efficiency at 75% unity P.F.
i) on 100% load (%)
ii) on 75% load (%)
iii) on 50% load (%)
iv) on 25% load (%)
18. Efficiency at 75 Deg. C. 0.8. p.f., (Lag)
i) on 100% load (%)
ii) on 75% load (%)
iii) on 50% load (%)
iv) on 25% load (%)
19. Load at which maximum efficiency
occurs (% of full load)
20. Maximum efficiency (%)
21. a) Percentage reactance at rated
current and frequency (%)
b) Percentage impedance at rated
current and frequency at 75%
i. Positive sequence (%)
ii. Zero sequence (%)
c) Range of variation +/- offered in items
of clause 1.17
d) Tolerance, applicable if any.
22. Impedance voltage drop at normal ratio
at 75 Deg. C expressed voltage on full
load (%)
23. Regulation on full load at unity p.f. at 75
Deg.C expressed as a percentage of
normal voltage (%)
24. Regulation on full load at 0-8 p.f. lagging
at 750 C expressed as a percentage of
normal voltage (%).
25. Maximum current density in the
winding:-
i) H.V. (Amps/Sq.cm.)
ii) L.V. (Amps/Sq.cm.)
26. Minimum flux density in the core
(Lines/Sq.c.m.)
27. Core joints (butt or interleaved)
28. Type of winding
i) H.V.
ii) L.V.
29. Type of radial supports
i) H.V. winding
ii) L.V. winding
30. Insulation of higher voltage winding
31. Insulation of lower voltage winding
32 Insulation of core bolts
33. Insulation of core bolts washers
34. Insulation of core and plates
35. Insulation of core Laminations
36. Thickness of transformer tank plates
i) Sides (mm)
ii) Bottom (mm)
iii) Cover (mm)
iv) Tube radiators (mm)
37. Test Voltages
A. Power frequency High voltage Test
i) Test voltage for l min with
stand test on line end of high
voltage winding (KVRMS)
ii) Test voltage for l1 min,
withstand test on neutral end of
the high voltage winding (KVRMS)

iii) Test voltage or 1 min. withstand


test on both line and neutral
ends of low voltage winding
(KVRMS)
B. Impulse Tests:
i) Test voltage for 1.2/50 micro
second full wave withstand test on
huge voltage winding ( KV crest)
ii) Test voltage for 1.2/50 micro
second full wave withstand test on
high voltage winding(KV crest)
38. Inter-turn Insulation
i) Extent of end turns reinforcement
(%)
ii) Extent of reinforcement of turns
adjacent to tapings (%)
iii) Test voltage for 1 min. 50 HZ
inter-turn insulation test on (i)
(above) (KV RMS)
iv) Test voltage for 1 min. 50 HZ.
Inter-turn insulation test on (ii)
above(KV RMS)
v) Test voltage for 1 min. 50 HZ.
Inter-turn insulation test on
main body of the
winding (KV RMS)
39. Type of winding temperature indication.
40. Maximum continuous ratings
i) at 50C ambient air temp. at site
(KVA)
ii) at 40C ambient air temp. at site
(KVA)
iii) at 30C ambient air temperature
at site (KVA)
iv) at 25C ambient air temp. at site
(KVA)
41. Power taken by heater in conservator
tank in watts at 240 volts single phase or
at 400 volts, three phase.
42. Width of track gauge (meters)
43. Bushing Particulars
i) Type of high voltage bushing and
creepage distance in mm.
ii) Weight of high voltage bushing in kgs.
iii) Quantity of oil in one high voltage
bushing insulator in liters
iv) Dry 1 min. power frequency
withstand test voltage value of high
voltage bushing in KV.
v) Wet 10 second power frequency test
voltage value of high voltage bushing in
KV
vi) Impulse withstand test voltage value
with 1.2/50 micro second full wave
of high voltage bushing in KV
vii)Type of low voltage bushing and
creepage distance in mm.

viii) Weight of low voltage bushing


insulator in Kgs.
ix) Quantity of oil in one low voltage
bushing insulator in liters.
x)Dry 1 min-power frequency withstand
test voltage value of low voltage
bushing in KV
xi) Wet 10 second power frequency
withstand test voltage value of
low voltage bushing in KV
xii) Impulse withstands test voltage
value with 1.2/50 micro second full
wave of low voltage bushing in KV.
Xiii) Whether the bushing are
hermetically sealed or not.
44. Clearances
a) Minimum clearances between
phases (mm)
i) In oil
ii) Out of oil
b) Minimum clearances high voltage to
earth in oil (mm)
c) Minimum clearance high voltage to
tank in oil (mm)
45. Net weight of the core (Kgs.)
46. Net weight of copper:-
a) HV (Kgs)
b) LV (Kgs)
c) Total (Kgs)
47. Weight of core and windings(Kgs)
48. Weight of fittings and parts detached for
transport (Kgs.)
49. Net un tanking weight (Kgs)
50. Weight of tank and cover (Kgs)
51. Weight of tank and cover (Kgs)
52. Weight of oil in transformer (including
bushings) (Kgs)
53. Weight of complete transformer with all
fittings and oil (Kgs.)
54. Weight of complete transformer with all
fittings but without oil (Kgs.)
55 Weight of the heaviest shipment package
(Kgs)l
and dimensions
56. Dimensions of the transform

i) Maximum height to top of bushings


(mm)
ii) Overall length (mm)
iii) Overall width (mm)
57. Minimum clear height for lifting core and
winding from tank in meters.
58. Details of on load tap changing gear :
a) Make
b) Type
c) Rating
i) Rated voltage
ii) Rated current
iii) Step voltage
iv) No. of steps
d) Time for complete tap change
e) Diverter selector switch transition
time (cycles)
f) Control
g) Auxiliary supply details
h) Voltage control
i) Line drop compensation
j) Protection devices
k) Value of maximum short circuit
l) Maximum impulse withstand test
voltage value with 1.2/50 micro
second full wave between switch and
ground
m) Maximum impulse withstand test voltage with 1.250Micro
second full wave between the remote terminal and ground
with the selector terminal at one end of the range.
n) Maximum power frequency test voltage between switch
assembly and ground.
o) Maximum impulse withstand test voltage with 1.2/50
micro second test across the tapping range.
p) Maximum temperature of the tap changer which must
not be exceeded during operation
q) Approximate overall weight (Kgs)
r) Approximate overall dimensions
s) Approximate overall quantity of oil
(Kgs.)
t) Nos of operations after which change of oil is necessary.
59. Any other particulars which need a mention.
60. Technical particulars of Bushing type/turret mounted
current Transformers.
a) Rated Primary Current.
b) Rated Secondary Current.
c) Rated Output.
d) Class of Accuracy.
e) Max. knee point voltage

f) Resistance of the secondary winding at 750 C.


g) Secondary limiting voltage.

Place: Signature:
Date: Name:
Status:
Whether authorized attorney: