Sei sulla pagina 1di 1

PT SMART Tbk

Additional Reservoir
Padang Halaban 60 TPH Palm Oil Mill

TECHNICAL SPECIFICATIONS FOR CIVIL WORKS


CODE NO RS.01 RESERVOIR DATE Jan 2017
PROJECT SERVICE LOCATION MILL REVISION 0
PHLM-ADD.60-16-C-CF.01
PREPARED BY EPDV DRAWING NO SHEET NO 1 of 1
PHLM-ADD.60-16-C-DW

1. GENERAL

1.1 Dimension, shape, construction detail, quality of material, and construction methods must
refer to Civil Drawings and General Specifications for Civil Works.

1.2 Scope of work includes :


1.2.1 Soil cut and fill to reach the design level of new kolam air.
1.2.2 Dewatering system for cut and fill during kolam air construction.
1.2.3 Boring for deep well of dewatering.

2. SOIL CUT AND FILL FOR KOLAM AIR

2.1 Existing ground must be cut until reached design level, as per drawings.
2.2 Soil fill must be compacted per 150 mm thick layer with whelled roller.
2.3 Surrounding area of kolam air to be applied clay liner to provide impermeable layer as
thick as 2.4 m, as per drawings.
2.4 General specification material for clay liner :
2.4.1 Soil material must be specified of SC, CL or CH based on Unified Soil
Classification system.
2.4.2 Soil permeability must be < 10-7cm/det .
2.4.3 Total amount of gravel, particle with 4.76 mm in size, must be < 30%.
2.4.4 Soil plasticity index must be 7 - 10%.
2.4.5 Maximum soil particle size must be 25 - 50 mm.

3. DEWATERING SYSTEM

3.1 Dewatering system must be operated before and during construction.


3.2 Dewatering must be done until ground water level reached 7.5 m below existing ground
level.
3.3 Dewatering used 12 nos. of submersible pump which it's capacity minimum 300 lt/menit.
Layout of deep well dewatering point, as per drawing.
3.4 Deep well is 300 mm in diameter and 12.5 m deep. Contractor must provided boring
equipment to construct it deep well for dewatering.
3.5 Water discharge from pumping process to be discarded from construction site with open
drain. Open drain is made of excavation of existing soil, with 800 mm width and 500 mm
depth, covered with plastic layer/terpal, flowed to lower level of existing ground.

Potrebbero piacerti anche