A trusted partner
We support our customers throughout their project lifecycle, from Through our internal technical support function, International Technical
the design to the end-of-life phase. Every step of the way, we strive Services Americas, thyssenkrupp trains its service technicians in a
to fully understand their needs and consistently deliver the safest, multibrand portfolio, enabling them to successfully service more than
highest quality passenger transportation solutions, maintenance and 1.2 million units under maintenance.
modernization packages.
One World
Trade Center
Mercedes Benz
thyssenkrupp Quartier
5
C
ontents
Low-rise | endura hydraulic elevators 06
endura MRL machine room-less 08
endura above-ground 10
endura below-ground 12
endura machine rooms and controllers 14
Interior design 30
Standard cab finish options 32
Finishes color selections 35
Accessories ceilings, handrails and sills 36
Fixtures standard and upgraded 37
Upgraded and custom cabs 40
Door configurations and entrance details 44
Table of Contents
6
Reliable.
Dependable.
Powerful.
above-ground
C Hoistway width
D Hoistway depth
I H O E Clear door opening
F Inside clear width
2100 3
6'-0" x 5'-8" 7'-4" x 6'-8" 7'-8" x 6'-8" F/R 5'-8" x 4'-3" One-speed 3'-0"
G G B D
2500 7'-0" x 5'-1" 8'-4" x 5'-9" 8'-8" x 5'-9" F 6'-8" x 4'-3" One-speed 3'-6" F F
2500 7'-0" x 5'-8" 8'-4" x 6'-8" 8'-8" x 6'-8" F/R 6'-8" x 4'-3" One-speed 3'-6"
E E
3000 7'-0" x 5'-7" 8'-4" x 6'-3" 8'-8" x 6'-3" F 6'-8" x 4'-9" One-speed 3'-6"
A A
3000 7'-0" x 6'-2" 8'-4" x 7'-2" 8'-8" x 7'-2" F/R 6'-8" x 4'-9" One-speed 3'-6" C C
3500 4
7'-0" x 6'-3" 8'-4" x 6'-11" 8'-8" x 6'-11" F 6'-8" x 5'-5" One-speed 3'-6"
3500 4 7'-0" x 6'-10" 8'-4" x 7'-10" 8'-8" x 7'-10" F/R 6'-8" x 5'-5" One-speed 3'-6"
4000 4
8'-0" x 6'-3" 9'-4" x 6'-11" 9'-8" x 6'-11" F 7'-8" x 5'-5" One-speed 3'-6"/4'-0" Front and rear opening (F/R)
4000 4 8'-0" x 6'-10" 9'-4" x 7'-10" 9'-8" x 7'-10" F/R 7'-8" x 5'-5" One-speed 3'-6"/4'-0"
S A Platform width
B Platform depth
C Hoistway width
Dimensional data shown above is for both seismic and non-seismic zones and complies with
current ASME A17.1 and CSA B44 Safety Code for Elevators. Local codes may vary from the D Hoistway depth
national codes. Consult your thyssenkrupp Elevator representative for details. I H O E Clear door opening
F Inside clear width
H Inside clear cab height: 7'-4" 5 I Entrance height: 7'-0" P Pit depth: 4'-0"
G Inside clear depth
O Minimum overhead: T Additional max travel: S Safety beam required H Inside clear height
1, 2 & 3 Stage Jack
1
5'-0" min. pit is required for additional travel. Travel above 13'-8" (1-Stage) or 25'-2" (2-Stage) or 36'-6" (3-Stage)
A One-speed One-speed
requires additional pit and/or overhead by adding 1" for every 1" (1-Stage) or 2" (2-Stage) or 3" (3-Stage) of additional side-opening doors center-opening doors
travel. Max increase 2'-0" allowed in overhead.
2 In areas where a 7" deep pit ladder is required, additional hoistway width or wall pocket will be required.
3 T his capacity is not available with center-opening doors. G G B D
4 To meet the requirements of IBC code for 84" stretchers, a 4'-0" center-opening (for 4000 lbs capacity only) F F
or 3'-6" side-opening (for 3500 lbs or 4000 lbs capacity) door is required.
5 Dimension shown is based on suspended ceiling design. An increase in cab height will result in an increase in E E
overhead requirements. A A
6 Provided and installed by others, as directed by your thyssenkrupp Elevator representative. Clear overhead is shown to C C
the bottom of the safety beam.
endura MRL 9
4500 3 6'-0" x 8'-9" 7'-4" x 9'-6" 7'-8" x 9'-6" F 5'-8" x 7'-9" Two-speed 4'-0"/4'-6"
Two-speed 3
4500 6'-0" x 9'-5" 7'-4" x 10'-9" 7'-8" x 10'-9" F/R 5'-8" x 7'-10" Two-speed 4'-0"/4'-6"
side-opening doors G B D
5000 3 6'-0" x 9'-4" 7'-4" x 10'-2" 7'-8" x 10'-2" F 5'-8" x 8'-5" Two-speed 4'-0"/4'-6"
F 3
5000 6'-0" x 10'-1" 7'-4" x 11'-4" 7'-8" x 11'-4" F/R 5'-8" x 8'-5" Two-speed 4'-0"/4'-6"
3
5000H 6'-0" x 9'-11" 7'-4" x 10'-9" 7'-8" x 10'-9" F 5'-8" x 9'-0" Two-speed 4'-0"/4'-6"
E
A 5000H 3 6'-0" x 10'-8" 7'-4" x 11'-11" 7'-8" x 11'-11" F/R 5'-8" x 9'-0" Two-speed 4'-0"/4'-6"
C
Dimensional data shown above is for both seismic and non-seismic zones and complies with
Front and rear opening (F/R) current ASME A17.1 and CSA B44 Safety Code for Elevators. Local codes may vary from the
A Platform width S
national codes. Consult your thyssenkrupp Elevator representative for details.
B Platform depth
H Inside clear cab height: 7'-4" 4 I Entrance height: 7'-0" P Pit depth: 4'-0"
C Hoistway width
D Hoistway depth O Minimum overhead: T Additional max travel: S Safety beam required
E Clear door opening I H O Up to 100 fpm: Over 100 fpm: 1-Stage: per OSHA 1926.502 6
F Inside clear width 1-Stage 12'-2" 1-Stage 12'-5" Up to 100 fpm 18'-11"
2-Stage 12'-8" 2-Stage 12'-8" Over 100 fpm 18'-8" 1
G Inside clear depth
3-Stage 12'-11" 3-Stage 12'-11" 2-Stage: 28'-6" 1
H Inside clear height 3-Stage: 48'-3" 1
1, 2 & 3 Stage Jack
I Entrance height T
O Overhead
P Pit depth
S Safety beam I
T Travel
P
1
5'-0" min. pit is required for additional travel. Travel above 13'-8" (1-Stage) or 25'-2" (2-Stage) or 36'-6" (3-Stage)
A
requires additional pit and/or overhead by adding 1" for every 1" (1-Stage) or 2" (2-Stage) or 3" (3-Stage) of additional
travel. Max increase 2'-0" allowed in overhead. (For 4500 and 5000 lbs capacities, max additional travel and speed
B D could be reduced based on cab weights. Consult your thyssenkrupp Elevator representative for details.)
Two-speed G
side-opening doors 2
In areas where a 7" deep pit ladder is required, additional hoistway width or wall pocket will be required.
F 3
W ith optional 4'-6" two-speed side-opening door, hoistway width becomes 8'-2".
4
imension shown is based on suspended ceiling design. An increase in cab height will result in an increase in
D
E overhead requirements.
A 5
rovided and installed by others, as directed by your thyssenkrupp Elevator representative. Clear overhead is shown to
P
C the bottom of the safety beam.
10
above-ground
C Hoistway width
D Hoistway depth
I H O E Clear door opening
F Inside clear width
2100 3
6'-0" x 5'-8" 7'-4" x 6'-8" 7'-8" x 6'-8" F/R 5'-8" x 4'-3" One-speed 3'-0"
G G B D
2500 7'-0" x 5'-1" 8'-4" x 5'-9" 8'-8" x 5'-9" F 6'-8" x 4'-3" One-speed 3'-6" F F
2500 7'-0" x 5'-8" 8'-4" x 6'-8" 8'-8" x 6'-8" F/R 6'-8" x 4'-3" One-speed 3'-6"
E E
3000 7'-0" x 5'-7" 8'-4" x 6'-3" 8'-8" x 6'-3" F 6'-8" x 4'-9" One-speed 3'-6"
A A
3000 7'-0" x 6'-2" 8'-4" x 7'-2" 8'-8" x 7'-2" F/R 6'-8" x 4'-9" One-speed 3'-6" C C
3500 4
7'-0" x 6'-3" 8'-4" x 6'-11" 8'-8" x 6'-11" F 6'-8" x 5'-5" One-speed 3'-6"
3500 4 7'-0" x 6'-10" 8'-4" x 7'-10" 8'-8" x 7'-10" F/R 6'-8" x 5'-5" One-speed 3'-6"
4000 4
8'-0" x 6'-3" 9'-4" x 6'-11" 9'-8" x 6'-11" F 7'-8" x 5'-5" One-speed 3'-6"/4'-0" Front and rear opening (F/R)
4000 4 8'-0" x 6'-10" 9'-4" x 7'-10" 9'-8" x 7'-10" F/R 7'-8" x 5'-5" One-speed 3'-6"/4'-0"
S A Platform width
B Platform depth
C Hoistway width
Dimensional data shown above is for both seismic and non-seismic zones and complies with
current ASME A17.1 and CSA B44 Safety Code for Elevators. Local codes may vary from the D Hoistway depth
national codes. Consult your thyssenkrupp Elevator representative for details. I H O E Clear door opening
F Inside clear width
H Inside clear cab height: 7'-4" 5 I Entrance height: 7'-0" P Pit depth: 4'-0"
G Inside clear depth
H Inside clear height
O Minimum overhead: T Additional max travel: S Safety beam required
1, 2 & 3 Stage Jack
1
dditional travel in note T (above) is obtained by adding 1" of overhead/pit for every 1" (1-Stage) or 2" (2-Stage)
A
or 3" (3-Stage) of net travel over the standard. Max 2'-0" allowed in overhead. One-speed One-speed
side-opening doors center-opening doors
2
In areas where a 7" deep pit ladder is required, additional hoistway width or wall pocket will be required.
3
T his capacity is not available with center-opening doors.
4
o meet the requirements of IBC code for 84" stretchers, a 4'-0" center-opening (for 4000 lbs capacity only) or 3'-6"
T G G B D
side-opening (for 3500 lbs or 4000 lbs capacity) door is required.
F F
5
imension shown is based on suspended ceiling design. An increase in cab height will result in an increase in
D
overhead requirements.
E E
6
rovided and installed by others, as directed by the local thyssenkrupp office. Clear overhead is shown to the bottom of
P A A
the safety beam.
C C
* Refer to page 14 for elevator machine room sizes.
endura11
4500 2 6'-0" x 8'-9" 7'-4" x 9'-6" 7'-8" x 9'-6" F 5'-8" x 7'-9" Two-speed 4'-0"/4'-6"
Two-speed
side-opening doors G 4500 2
6'-0" x 9'-5" 7'-4" x 10'-9" 7'-8" x 10'-9" F/R 5'-8" x 7'-10" Two-speed 4'-0"/4'-6"
B D
5000 2 6'-0" x 9'-4" 7'-4" x 10'-2" 7'-8" x 10'-2" F 5'-8" x 8'-5" Two-speed 4'-0"/4'-6"
F
5000 2
6'-0" x 10'-1" 7'-4" x 11'-4" 7'-8" x 11'-4" F/R 5'-8" x 8'-5" Two-speed 4'-0"/4'-6"
5000H 2
6'-0" x 9'-11" 7'-4" x 10'-9" 7'-8" x 10'-9" F 5'-8" x 9'-0" Two-speed 4'-0"/4'-6"
E
A 5000H 2 6'-0" x 10'-8" 7'-4" x 11'-11" 7'-8" x 11'-11" F/R 5'-8" x 9'-0" Two-speed 4'-0"/4'-6"
C
Dimensional data shown above is for both seismic and non-seismic zones and complies with
Front and rear opening (F/R) current ASME A17.1 and CSA B44 Safety Code for Elevators. Local codes may vary from the
A Platform width S
national codes. Consult your thyssenkrupp Elevator representative for details.
B Platform depth
H Inside clear cab height: 7'-4" 3 I Entrance height: 7'-0" P Pit depth: 4'-0"
C Hoistway width
D Hoistway depth O Minimum overhead: T Additional max travel: S Safety beam required
E Clear door opening I H O Up to 100 fpm: Over 100 fpm: 1-Stage: per OSHA 1926.502 4
F Inside clear width 1-Stage 12'-2" 1-Stage 12'-5" Up to 100 fpm 18'-11"
2-Stage 12'-8" 2-Stage 12'-8" Over 100 fpm 18'-8" 1
G Inside clear depth
3-Stage 12'-11" 3-Stage 12'-11" 2-Stage: 28'-6" 1
H Inside clear height
3-Stage: 48'-3" 1
1, 2 & 3 Stage Jack
I Entrance height T
O Overhead
P Pit depth
S Safety beam I
T Travel
P
1
dditional travel in note T (above) is obtained by adding 1" of overhead/pit for every 1" (1-Stage) or 2" (2-Stage) or
A
3" (3-Stage) of net travel over the standard. Max 2'-0" allowed in overhead. (For 4500 and 5000 lbs capacities, max
additional travel and speed could be reduced based on cab weights. Contact your local thyssenkrupp office for details.)
Two-speed G B D
side-opening doors 2
W ith optional 4'-6" two-speed side-opening door, hoistway width becomes 8'-2".
F
3
imension shown is based on suspended ceiling design. An increase in cab height will result in an increase in
D
overhead requirements.
E
4
rovided and installed by others, as directed by the local thyssenkrupp office. Clear overhead is shown to the bottom of
P
A the safety beam.
C *R
efer to page 14 for elevator machine room sizes.
12
ground I H O
D Hoistway depth
E Clear door opening
F Inside clear width
Passenger
Cap Platform Hoistway1 Front/ Inside clear Door Door
(lbs) AxB CxD rear FxG type width One-speed One-speed
side-opening doors center-opening doors
2100 2 6'-0" x 5'-1" 7'-4" x 5'-9" F 5'-8" x 4'-3" One-speed 3'-0"
2100 2 6'-0" x 5'-8" 7'-4" x 6'-8" F/R 5'-8" x 4'-3" One-speed 3'-0"
3500 3 7'-0" x 6'-10" 8'-4" x 7'-10" F/R 6'-8" x 5'-5" One-speed 3'-6"
4000 3
8'-0" x 6'-3" 9'-4" x 6'-11" F 7'-8" x 5'-5" One-speed 3'-6"/4'-0"
Front and rear opening (F/R)
4000 3 8'-0" x 6'-10" 9'-4" x 7'-10" F/R 7'-8" x 5'-5" One-speed 3'-6"/4'-0" S A Platform width
B Platform depth
C Hoistway width
Dimensional data shown above is for both seismic and non-seismic zones and complies with D Hoistway depth
current ASME A17.1 and CSA B44 Safety Code for Elevators. Local codes may vary from the I H O E Clear door opening
national codes. Consult your thyssenkrupp Elevator representative for details.
F Inside clear width
H Inside clear cab height: 7'-4" 4 I Entrance height: 7'-0" O Minimum overhead: G Inside clear depth
Up to 100 fpm 12'-0" H Inside clear height
Over 100 fpm 12'-3"
T I Entrance height
O Overhead
P Pit depth: 4'-0" S Safety beam required X Standard jack hole depth:
P Pit depth
per OSHA 1926.502 5 Travel + 6'-0"
I S Safety beam
T Travel
P
X Jack hole depth
X
One-speed One-speed
1
In areas where a 7" deep pit ladder is required, additional hoistway width or wall pocket will be required. side-opening doors center-opening doors
2
T his capacity is not available with center-opening doors.
3
o meet the requirements of IBC code for 84" stretchers, a 4'-0" center-opening (for 4000 lbs capacity only) or 3'-6"
T
side-opening (for 3500 lbs or 4000 lbs capacity) door is required. G G B D
4
imension shown is based on suspended ceiling design. An increase in cab height will result in an increase in
D F F
overhead requirements.
5
rovided and installed by others, as directed by the local thyssenkrupp office. Clear overhead is shown to the bottom of
P E E
the safety beam. A A
* Refer to page 14 for elevator machine room sizes. C C
endura13
Below-
D Hoistway depth
E Clear door opening
F Inside clear width
I H O
ground
G Inside clear depth
Service elevators
H Inside clear height
I Entrance height T Jack types Travel Speed Capacity
O Overhead Conventional 60'-0" 80-200 fpm 4500-5000 lbs
P Pit depth
Click Jack type for specific product specs
S Safety beam I
T Travel
P
X Jack hole depth
X
Service
Cap Platform Hoistway1 Front/ Inside clear Door Door
(lbs) AxB CxD rear FxG type width
F
5000 2
6'-0" x 10'-1" 7'-4" x 11'-4" F/R 5'-8" x 8'-5" Two-speed 4'-0"/4'-6"
5000H 2
6'-0" x 9'-11" 7'-4" x 10'-9" F 5'-8" x 9'-0" Two-speed 4'-0"/4'-6"
E
5000H 2 6'-0" x 10'-8" 7'-4" x 11'-11" F/R 5'-8" x 9'-0" Two-speed 4'-0"/4'-6"
A
C
Front and rear opening (F/R) Dimensional data shown above is for both seismic and non-seismic zones and complies with
current ASME A17.1 and CSA B44 Safety Code for Elevators. Local codes may vary from the
A Platform width S national codes. Consult your thyssenkrupp Elevator representative for details.
B Platform depth
C Hoistway width H Inside clear cab height: 7'-4" 3 I Entrance height: 7'-0" O Minimum overhead:
Up to 100 fpm 12'-0"
D Hoistway depth
Over 100 fpm 12'-3"
E Clear door opening I H O
O Overhead
P Pit depth
S Safety beam I
T Travel
P
X Jack hole depth
X
Two-speed
side-opening doors G B D
1
In areas where a 7" deep pit ladder is required, additional hoistway width or wall pocket will be required.
2
W ith optional 4'-6" two-speed side-opening door, hoistway width becomes 8'-2".
F 3
imension shown is based on suspended ceiling design. An increase in cab height will result in an increase in
D
overhead requirements.
E 4
rovided and installed by others, as directed by the local thyssenkrupp office. Clear overhead is shown to the bottom of
P
A the safety beam.
C
*R
efer to page 14 for elevator machine room sizes.
14 endura
Machine room
Hydraulic elevator
machine rooms
Your endura system determines the machine room youll need.*
The most desirable controller closet location is on the lowest floor served, adjacent to the elevator
hoistway. At an additional cost, the machine room can be located remotely from hoistway.
Power unit
Power unit
B E
Disconnect
Disconnect
switch
C switch Power unit
(by others) F
(by others)
Single-car Dual-car
Power unit A B C1 Door height Room height Power unit D E F1 Door height Room height
Submersible (large) 7'-2" 7'-1" 4'-0" Min 7'-0" Min 7'-6" Submersible (large) 10'-5" 10'-5" 4'-0" Min 7'-0" Min 7'-6"
Dry (large) 9'-10" 5'-6" 4'-0" Min 7'-0" Min 7'-6" Dry (large) 14'-7" 7'-0" 4'-0" Min 7'-0" Min 7'-6"
1
Clear opening.
* C onsult your thyssenkrupp Elevator representative to help determine your needs, as machine room arrangements may vary from those shown.
15
Hydraulic MRL
controller details
endura MRL controller
Our endura MRL is designed to maximize space by locating the
controller in the elevator entrance jamb. As a result, we require a
minimum 8" actual wall thickness at the floor where the controller will be
located. The wall construction can be done with dry wall or masonry
block. For installation purposes, however, the entire wall at the controller
level must be left out until the elevator frame and controller are in place.
The controller must be located at the landing directly above the lowest
landing served by the elevator. If that is not possible, the location must
be coordinated with your thyssenkrupp Elevator representative. Perspective view
8"min.
8" min. 8" min.
required
required Building power
Building power required Building power
Entrance
plan view
F-F Wallfinish
Wall finish Lobby side
Wall finishLobby side "
" Lobby side
1"shaftliner
1" shaftliner filler
filler by
by G.C.
G.C. 1" shaftliner
(Doorfiller by
width) G.C.
2"
2" (Door width) 2" (Door width)
Fire alarm
Fire alarm face opening Fire alarm
Clear opening
face Clear face Clear opening
Phone
Phone Phone
FF EE F FF E
2"2"
2"
+2"
height
Section
height)+2"
openingheight
Controller entrance
(Entranceheight)
(Entrance height)
(Entranceheight)
E-E
Clearopening
elevation
Overallframe
(Entrance
(Entrance
Overall
Clear
Flexible.
Efficient.
Smart.
Low-rise to mid-rise
traction MRL
Traction elevators provide optimal ride quality, faster speeds and
expend less time and energy to move people in your building.
Self-supported Building-supported
Supported by elevator rails Supported by building
The self-supported configuration enables the loads imposed The building-supported configuration requires structural
by the elevator system to be transferred from the machine at support by the building. As a result, this elevator is able to
the top of the hoistway, down the guide rails, to the pit below. achieve faster speeds and higher capacities.
Buildings with travel distance up to 85'-0" Buildings with travel distance up to 300'-0"
Elevators with capacities up to 3500 lbs and Elevators with capacities up to 5000 lbs and
speeds of 150 fpm speeds up to 500 fpm
Standard cab finishes and flooring Standard and upgraded finishes and flooring
synergy19
Beam by others
Machine Beam Supported in Beam Pocket Machine Beam Supported by Structural Steel
20
Self- R
S A Platform width
B Platform depth
supported
C Hoistway width
D Hoistway depth
I H O
E Clear door opening
F Inside clear width
Passenger standard
Cap Platform Hoistway 2 Front/ Inside clear Door Door width Min OH 7 One-speed One-speed
(lbs) AxB CxD rear FxG type E O side-opening doors center-opening doors
2100 3 6'-0" x 5'-1" 7'-4" x 5'-9" 5 F 5'-8" x 4'-3" One-speed 3'-0" 13'-0"
2100 3
N/A N/A F/R N/A N/A N/A N/A
G G B D
2500 7'-0" x 5'-1" 8'-4" x 5'-9" 5 F 6'-8" x 4'-3" One-speed 3'-6" 13'-0" F F
2500 7'-0" x 5'-8" 8'-4" x 6'-8" 6 F/R 6'-8" x 4'-3" One-speed 3'-6" 13'-0"
E E
3000 7'-0" x 5'-7" 8'-4" x 6'-3" 6
F 6'-8" x 4'-9" One-speed 3'-6" 13'-4" A A
3000 7'-0" x 6'-2" 8'-4" x 7'-2" 6 F/R 6'-8" x 4'-9" One-speed 3'-6" 13'-4" C C
3500 4
7'-0" x 6'-3" 8'-4" x 6'-11" 6
F 6'-8" x 5'-5" One-speed 3'-6" 13'-4"
3500 4 7'-0" x 6'-10" 8'-4" x 7'-10" 6 F/R 6'-8" x 5'-5" One-speed 3'-6" 13'-4"
and CSA B44 Safety Code for Elevators. Local codes may vary from the national codes. Consult R B Platform depth
your thyssenkrupp Elevator representative for details. C Hoistway width
D Hoistway depth
P Pit depth: 5'-0" H Inside clear cab height: 7'-2" 1 S Safety beam required
I H O E Clear door opening
per OSHA 1926.502 8
F Inside clear width
G Inside clear depth
H Inside clear height
T I Entrance height
O Overhead
P Pit depth
P Pit depth Upgraded cab 300'-0" 200, 350 fpm 2500-4000 lbs
Passenger standard
One-speed One-speed Cap Platform Hoistway 2 Front/ Inside clear Door Door width
side-opening doors center-opening doors (lbs) AxB CxD rear FxG type E
G G 2500 6
7'-0" x 5'-1" 9'-2" x 5'-9" 5
F 6'-8" x 4'-3" One-speed 3'-6"
B D
F F 2500 7'-0" x 5'-8" 9'-2" x 6'-8" 5 F/R 6'-8" x 4'-3" One-speed 3'-6"
3500 2
7'-0" x 6'-3" 8'-4" x 7'-10" 4
F 6'-8" x 5'-5" One-speed 3'-6"
3500 2,6 7'-0" x 6'-3" 9'-2" x 6'-11" 5 F 6'-8" x 5'-5" One-speed 3'-6"
4000 2,3
8'-0" x 6'-3" 9'-4" x 7'-10" 4 F 7'-8" x 5'-5" One-speed 3'-6"/4'-0"
A Platform width
4000 6
8'-0" x 6'-3" 10'-2" x 6'-11" 5
F 7'-8" x 5'-5" One-speed 3'-6"/4'-0"
B Platform depth R
4000 2,3
8'-0" x 6'-10" 10'-2" x 7'-10" 5 F/R 7'-8" x 5'-5" One-speed 3'-6"/4'-0"
C Hoistway width
D Hoistway depth
E Clear door opening I H O
Dimensional data shown above is for non-seismic zones and complies with current ASME A17.1
F Inside clear width
and CSA B44 Safety Code for Elevators. Local codes may vary from the national codes. Consult
G Inside clear depth your thyssenkrupp Elevator representative for details.
H Inside clear height
P Pit depth: O Minimum overhead: 1 H Inside clear cab height: 7'-2" 1
I Entrance height T 200 fpm: 5'-0" 200 fpm: 14'-9"
O Overhead 350 fpm: 5'-5" 350 fpm: 15'-5"
P Pit depth
R Car top railing I
T Travel
P
One-speed One-speed
side-opening doors center-opening doors
1
Inside clear cab heights up to 9'-2" available in 1" increments. Dimension shown is based on suspended ceiling design.
An increase in cab height will result in an increase in overhead requirements.
G G B D
2
o meet the requirements of IBC code for 84" stretchers, a 4'-0" center-opening (for 4000 lbs capacity only)
T
F F or 3'-6" side-opening (for 3500 lbs or 4000 lbs capacity) door is required.
3
200 fpm unavailable for 4000 lbs capacity.
E E 4
For Seismic Zones 2 or greater, add 2" to hoistway width.
A A
C C
5
For Seismic Zones 2 or greater, add 4" to hoistway width.
6
Configuration with side counterweight on front opening arrangement.
22
Building R
A Platform width
B Platform depth
supported
C Hoistway width
D Hoistway depth
I H O E Clear door opening
F Inside clear width
Passenger performance
Cap Platform Hoistway Front/ Inside clear Door Door width
(lbs) AxB CxD rear FxG type E One-speed One-speed
2100 2 6'-0" x 5'-1" 7'-4" x 6'-8" 4 F 5'-8" x 4'-3" One-speed 3'-0" side-opening doors center-opening doors
2500 7'-0" x 5'-8" 9'-2" x 6'-8" 5 F/R 6'-8" x 4'-3" One-speed 3'-6" G G
B D
F F
3000 7'-0" x 5'-7" 8'-4" x 7'-2" 4
F 6'-8" x 4'-9" One-speed 3'-6"
3000 7'-0" x 6'-2" 9'-2" x 7'-2" 5 F/R 6'-8" x 4'-9" One-speed 3'-6"
E E
3500 3 7'-0" x 6'-3" 8'-4" x 7'-10" 4 F 6'-8" x 5'-5" One-speed 3'-6" A A
C C
3500 3 7'-0" x 6'-10" 9'-2" x 7'-10" 5 F/R 6'-8" x 5'-5" One-speed 3'-6"
One-speed One-speed
side-opening doors center-opening doors
1
Inside clear cab heights available in 1" increments. Dimension shown is based on suspended ceiling design.
An increase in cab height will result in an increase in overhead requirements. G G B D
F F
2
This capacity is not available with center-opening doors.
3
o meet the requirements of IBC code for 84" stretchers, a 4'-0" center-opening (for 4000 lbs capacity only)
T E E
or 3'-6" side-opening (for 3500 lbs or 4000 lbs capacity) door is required.
A A
4
For Seismic Zones 2 or greater, add 4" to hoistway width and 2" to hoistway depth. C C
5
For Seismic Zones 2 or greater, add 7" to hoistway width.
synergy23
P Pit depth Upgraded cab 300'-0" 200, 350, 500 fpm 45005000 lbs
Service performance
Cap Platform Hoistway Front/ Inside clear Door Door width
(lbs) AxB CxD rear FxG type E
Two-speed 4500 2
6'-0" x 9'-5" 8'-2" x 10'-9" 3
F/R 5'-8" x 7'-10" Two-speed 4'-0"/4'-6"
side-opening doors G
B D 5000 2
6'-0" x 9'-4" 8'-2" x 10'-2" 3
F 5'-8" x 8'-5" Two-speed 4'-0"/4'-6"
F 5000 2 6'-0" x 10'-1" 8'-2" x 11'-4" 3 F/R 5'-8" x 8'-5" Two-speed 4'-0"/4'-6"
5000H 2
6'-0" x 9'-11" 8'-2" x 10'-9" 3
F 5'-8" x 9'-0" Two-speed 4'-0"/4'-6"
E
5000H 2 6'-0" x 10'-8" 8'-2" x 11'-11" 3 F/R 5'-8" x 9'-0" Two-speed 4'-0"/4'-6"
A
C
Dimensional data shown above is for non-seismic zones and complies with current ASME A17.1
Front and rear opening (F/R) and CSA B44 Safety Code for Elevators. Local codes may vary from the national codes. Consult
A Platform width your thyssenkrupp Elevator representative for details.
B Platform depth R
P Pit depth: O Minimum overhead: 1 H Inside clear cab height: 7'-4" 1
C Hoistway width 200 fpm: 5'-0" 200 fpm: 16'-4"
D Hoistway depth 350 fpm: 5'-5" 350 fpm: 16'-4"
E Clear door opening I H O 500 fpm: 6'-6" 500 fpm: 17'-6"
F Inside clear width
G Inside clear depth
H Inside clear height
I Entrance height T
O Overhead
P Pit depth
R Car top railing I
T Travel
P
Two-speed G B D
side-opening doors
F
1
Inside clear cab heights available in 1" increments. Dimension shown is based on suspended ceiling design. An increase in
cab height will result in an increase in overhead requirements.
E
A
2
With optional 4'-6" two-speed side-opening door, hoistway width remains 8'-2".
C 3
For Seismic Zones 2 or greater, add 7" to hoistway width.
24
Controller closets
synergy self-supported
The features of your synergy MRL traction system determine the controller closet youll need.*
The most desirable controller closet location is on the top floor served, adjacent to the elevator
hoistway. At an additional cost, it may be located remotely, but must be within 150 feet of wire
length from motor to controller. Consult your thyssenkrupp Elevator representative for details.
Simplex Duplex
D
A
Small Small
Includes room for Controller
Includes room for
controller, disconnect, B controller, disconnect,
Controller Controller
Disconnect switch
and resistor box. (by others) and resistor boxes.
E
Resistors1
F
C
Disconnect
switches
(by others)
A D
Large Large
Includes room for Transformer/ Controller Includes room for
resistor
controller, disconnect, B
controller, disconnect,
Controller Controller
emergency rescue, Disconnect switch emergency rescue,
(by others)
transformer and transformer and
resistor box. resistor boxes. E
Transformer/ Transformer/
resistor1 resistor1
F
C
Disconnect
switches
(by others)
Dimensional data shown above is for both seismic and non-seismic zones and complies 1
Devices are stacked in duplex configuration.
with current ASME A17.1 and CSA B44 Safety Code for Elevators. Local codes may vary 2
ontroller closet temperature range 32F minimum, 104F maximum.
C
from the national codes. Consult your thyssenkrupp Elevator representative for details.
10-95% non-condensing relative humidity.
* C onsult your thyssenkrupp Elevator representative to help determine your needs. 3
May also use two separate closets.
synergy25
Controller closets
synergy building-supported
The features of your synergy MRL traction system determine the controller closet youll need.*
The most desirable controller closet location is on the top floor served, adjacent to the elevator
hoistway. At an additional cost, it may be located remotely, but must be within 150 feet of wire
length from motor to controller. Contact your thyssenkrupp Elevator representative for details.
Simplex Duplex
A D
Standard Standard
Includes room for Includes room for
Controller
controller, disconnect, Transformer controllers, Transformers
Controller Controller
Disconnect switch
(by others)
A D
Performance Performance
Includes room for Includes room
Controller
controller, disconnect Transformer
for controllers, Controller Controller
Transformer
and transformer. disconnect and
B Disconnect switch transformer. E Disconnect switches
(by others)
Transformer (by others)
C
F
Simplex 1 Duplex 1
Size A B C Size D E F
1
C ontroller closet temperature range 32F minimum, 104F maximum. 1095% non-condensing relative humidity.
* C onsult your thyssenkrupp Elevator representative to help determine your needs.
26
Speed.
Innovation.
Freedom.
AC Y
R
S
Z
A Platform width
B Platform depth
C Hoistway width
gearless I H O
D Hoistway depth
E Clear door opening
F Inside clear width
Performance 825'-0" 700, 1000, 1200 fpm 25004000 lbs P Pit depth
I
R Car top railing
Click Car Type for specific product specs
S Safety beam
*
Higher travel, faster speed, and higher capacity available. P T Travel
Y MR depth
Passenger (P) Performance speed and travel available
Z MR height
Cap Platform Hoistway 2
Front/ Inside clear Door Door width
(lbs) AxB CxD rear FxG type E
One-speed One-speed
2100 1 6'-0" x 5'-1" 7'-4" x 5'-9" 3 F 5'-8" x 4'-3" One-speed 3'-0" side-opening doors center-opening doors
2500 (P) 7'-0" x 5'-1" 8'-4" x 6'-8" 7 F 6'-8" x 4'-3" One-speed 3'-6"
2500 7'-0" x 5'-8" 9'-2" x 6'-8" 4 F/R 6'-8" x 4'-3" One-speed 3'-6" G G
B D
3000 (P) 7'-0" x 5'-7" 8'-4" x 7'-2" 7
F 6'-8" x 4'-9" One-speed 3'-6" F F
3000 7'-0" x 6'-2" 9'-2" x 7'-2" 4 F/R 6'-8" x 4'-9" One-speed 3'-6"
E E
3500 2 (P) 7'-0" x 6'-3" 8-4" x 7'-10" 7 F 6'-8" x 5'-5" One-speed 3'-6" A A
C C
3500 2 7'-0" x 6'-10" 9'-2" x 7'-10" 4 F/R 6'-8" x 5'-5" One-speed 3'-6"
4000 2 (P) 8'-0" x 6'-3" 9'-4" x 7'-10" 4 F 7'-8" x 5'-5" One-speed 3'-6"/4'-0"
Front and rear opening (F/R)
S A Platform width
Y Z
Dimensional data shown above is for non-seismic zones and complies with current ASME A17.1 B Platform depth
and CSA B44 Safety Code for Elevators. Local codes may vary from the national codes. Consult R C Hoistway width
your thyssenkrupp Elevator representative for details.
D Hoistway depth
H Inside clear cab S Safety beam required Y Minimum machine room depth: P Pit depth
height: 7'-4" 5 per OSHA 1926.502 6 Standard: 16'-0" I
R Car top railing
Performance: 18'-0" S Safety beam
P T Travel
1
T his capacity is not available with center-opening doors. Y MR depth
2
o meet the requirements of IBC code for 84" stretchers, a 4'-0" center-opening (for 4000 lbs capacity only)
T Z MR height
or 3'-6" side-opening (for 3500 lbs or 4000 lbs capacity) door is required.
3
For seismic conditions, add 4" to hoistway width and 3" to hoistway depth. One-speed One-speed
side-opening doors center-opening doors
4
For seismic conditions, add 4" to hoistway width.
5
imension shown is based on suspended ceiling design. An increase in cab height will result in an increase
D
in overhead requirements.
G G B D
6
rovided and installed by others, as directed by the local thyssenkrupp office. Clear overhead is shown to the bottom of
P F F
the safety beam.
7
F or 1000 fpm speeds, add 2" to hoistway depth. For 1200 fpm speeds, add 2" to hoistway width and 4" to depth. E E
For seismic conditions on 700 fpm speeds, add 4" to hoistway width and 2" to depth. For 1000 and 1200 fpm speeds, A A
add 5" to hoistway width and 4" to depth.
C C
8
Minimum overhead can be reduced in some cases, consult your thyssenkrupp Elevator representative if required.
momentum29
P Pit depth
Click Car Type for specific product specs
R Car top railing
I
S Safety beam
T Travel
P
Y MR depth
Z MR height
Service
Cap Platform Hoistway Front/ Inside clear Door Door width
(lbs) AxB CxD rear FxG type E
Front and rear opening (F/R) Dimensional data shown above is for non-seismic zones and complies with current ASME A17.1
A Platform width S and CSA B44 Safety Code for Elevators. Local codes may vary from the national codes. Consult
Y Z
B Platform depth your thyssenkrupp Elevator representative for details.
C Hoistway width R
P Pit depth: O Minimum overhead: 5 Z Minimum machine room height:
D Hoistway depth 350 fpm: 15'-3"
350 fpm: 5'-0" Standard: 7'-6"
E Clear door opening I H O 500 fpm: 6'-6" 500 fpm: 16'-6"
F Inside clear width
G Inside clear depth H Inside clear cab S Safety beam required Y Minimum machine room depth:
H Inside clear height height: 7'-4" 3 per OSHA 1926.502 4 45005000 lbs: 19'-0"
I Entrance height T
O Overhead
P Pit depth
R Car top railing
I
S Safety beam
T Travel
P
Y MR depth
Z MR height
Two-speed
side-opening doors G
1
For seismic conditions, add 4" to hoistway width and 3" to hoistway depth.
B D
2
For seismic conditions, add 4" to hoistway width.
F 3
imension shown is based on suspended ceiling design. An increase in cab height will result in an increase
D
in overhead requirements.
E 4
rovided and installed by others, as directed by the local thyssenkrupp office. Clear overhead is shown to the
P
A bottom of the safety beam.
C 5
Minimum overhead can be reduced in some cases, consult your thyssenkrupp Elevator representative if required.
30
Beautiful.
Customizable.
Safe.
Interior design
Cab interiors can take on a beautiful form while they function,
so we give you choices. Customize your own or choose from our
upgraded cabs and let us do the work.
Standard cab
Laminated plastic options Level 1
Metals
33
Standard cab
Steel shell options Level 2
Metals
Metals
34
Standard cab
Applied panel options Level 3
Panel design
Mix beauty and practicality with this decorative and durable cab. The panel design is Click here to explore more
constructed with a high-quality steel shell and vertical raised panels made with a core of cab design options.
urea-formaldehyde-free wood.
Metals
Reveal, base, frieze finish options
Powder coats
Metals
35
Standard finishes
Finish selections
Plastic laminates
Woods
Solids
Patterns
Powder coats
Metals
Handrails
Sills
Our cab sill finishes allow you to match your sills to any other
Aluminum1
design component inside the cab. The standard sill design is
aluminum or bronze. You can upgrade the finish to nickel silver
for maximum durability.
Nickel silver
1
C omes standard. Finishes may vary based on your project selections.
2
L ighting options may vary depending on cab size.
3
Not available on all models.
37
Standard fixtures
Signa4
Push button
Available in blue & white LED lighting
Upgraded fixtures
Traditional
Position indicator
With directional arrows
Push button
Available in blue, white, red and green LED lighting
Terminal hall lantern
Vandal-resistant
Push button
Available in red, blue and white LED lighting
Piece
together
perfection.
Arrangement 3
41
Upgraded cabs
Arrangement 1 Arrangement 2
Custom-designed
look without the
custom price tag
Arrangement 4
As unique
as your
building.
43
Custom cabs
Custom ceilings
Complement your
dcor or make a
design statement.
Custom design
Elevator cab interiors are a blank slate. We can help you customize
to tastefully complement your buildings dcor or make a statement
with a unique design.
44
Door configurations
Door orientation options offer a range of benefits to accommodate different project needs.
Most economical
One-speed
The most economical door offering, available
with either right- or left-hand opening.
(right-hand shown) Opens right
Opens right
Interior of cab
Closed door position
Interior of cab
Closed door position
Interior of cab
Closed door position
Entrance details
Transoms
Panel height
2"
2"
1" Sill
F.F.
F.F.
F.F.
18 GA.
Center-opening and 18 GA.
Two-speed doors doors
door
single-speed doors
Sill support Sill support Sill s
supplied by 2" supplied by supp
support
3" Sill
support
3" Sill
support
3" Sill
Front walls should be left out until entrances are set in place or leave a minimum rough opening that Hand of doors is the direction the doors open, determined by standing inside of the elevator car
is 15" wider and 15" higher than frame opening of doorway. facing toward the doors.
Sill support details shown above are for thyssenkrupp Elevators standard entrance design. For additional entrance design and application arrangements, consult your thyssenkrupp Elevator
representative for details.
These diagrams show wall thickness and construction detail required in order to supply a minimum
fire resistance rating of 1 hours. Warnock Hersey Label on entrances. The dimension shown (3")
is the minimum wall thickness.
46
Intelligent.
Innovative.
Sustainable.
Innovations and
enhancements
Raise the standard in safety, sustainability and performance
with thyssenkrupps innovations.
Your elevator system becomes more agile with latest emergency exit equipment with our thyssenkrupp has
our intelligent control system that reduces wait first in the industry evacuation solution that over 215 LEED
times and keeps your elevators secure. Move utilizes elevators. Were also at the forefront of professionals to
more people in fewer elevator shafts with the our industry when it comes to sustainability. help guide our
TWIN elevator system that operates two cabs From elevator products to lighting to customers as they
in one hoistway. Predictive and pre-emptive LEED-certified manufacturing facilities; we build projects with
maintenance is provided with the Internet of are taking the right actions today for a better tomorrow in mind.
Things-enabled MAX. And employ the absolute world tomorrow.
AGILE
Elevator technology 48
TWIN
Elevator system 50
MAX
Predictive maintenance 52
Occupant
Evacuation operation 53
This is
AGILE.
For quicker, smarter,
more flexible elevators
49
TWIN is in compliance with ASME A17.7/CSA B44.7; A17.7 specifically intended for new elevator technology and practices.
Safety level 3 and 4 will be monitored by an independent control system according to IEC EN 61508 giving TWIN the highest safety classification of Safety Integrity Level 3 (SIL3).
System satisfies the regulations in accordance with elevator directive 95/16/EC and EN 81-1 with approved deviations and is EN 81-A3 compliant.
MAX
Predictive
Maintenance
MAX
This smart elevator-monitoring solution will improve ride
efficiency and alert technicians to potential problems before
breakdowns happen.
Occupant
Evacuation
Operation
www.thyssenkruppelevator.com
thyssenkrupp Elevator Corporation
All illustrations and specifications are based on information in effect at time of publication approval.
thyssenkrupp Elevator reserves the right to change specifications or design and to discontinue items without prior notice or obligation.
2017 thyssenkrupp Elevator Corporation. CA License #C11-651371 | 1232 | Elevator product guide catalog