Sei sulla pagina 1di 2

JobName/Location: Tag#:

Date: For: File Resubmit


PONo.: Approval Other
Architect: GC:
Engr: Mech:
Rep:
(Company) (ProjectManager)

ARNU48GTMC4
MultiV4WayCeilingCassette
48,100 Btu/hIndoorUnit
Performance: EnteringMixedAir:
TotalCoolingCapacity(Btu/h) 48,100 CoolingMax(FWB) 76
HeatingCapacity(Btu/h) 51,200 HeatingMin(FDB) 59
PowerInput(W) 144
CoolingNominalTestConditions: HeatingNominalTestConditions:
UnitData:
Indoor: 80FDB/67FWB Indoor: 70FDB
RefrigerantType R410A
Outdoor 95FDB Outdoor 47FDB/43FWB
: :
Electrical: RefrigerantControl EEV

PowerSupply(V/Hz/) 208230/60/1 SoundPressuredB(A)(H/M/L) 46/42/40


RatedAmps(A) 1.3 PrimaryFilterType Washable
Piping: SecondaryFilterType Plasma
Refrigerant: NetWeight(Kg) 25.6
LiquidLine(in,OD) 3/8Flare ShippingWeight(Kg) 30.1
VaporLine(in,OD) 5/8Flare GrilleWeight(Kg) 5.9
Condensate: GrilleShippingWeight(Kg) 9

CondensateLine(in,ID) 1
Fan:
FactoryInstalledPump Yes
Type Turbo
ControlsFeatures: Quantity 1
Autochangeover Groupcontrol Autodirec on/swing
(HeatRecoveryOnly) Highceiling (up/down) Motor/Drive BrushlessDigitallyControlled/Direct
Autoopera on Hotstart Fanspeedcontrol MotorQuantity 1
Autorestart Selfdiagnos cs Swirlwind
Externalon/offcontrol Timer(on/o) (alternatingvanes) AirflowRateH/M/L(CFM) 1,130/953/883
Dualthermistorcontrol Weeklyschedule Jetcool(fastcooling)
Dualsetpointcontrol Filterlifeandpower Multipleauxheater
Notes:
1.ThePowerInputisratedathighspeed.
consumptiondisplay applications 2.Maximumli is27infrombo omofunit.
RequiredAccessories: 3.SeeEngineeringManualforsensibleandlatentcapaci es.
4.SoundPressurelevelsaretestedinananechoicchamberunderISOStandard3745.
GrilleKit[PTUMC1,orPTUMC1B(Black)] 5.Plasmafilterkitaccessoryavailableseparately.
6.Allcommunica oncabletobeminimum18AWG,2conductor,stranded,shieldedandmust
OptionalAccessories: complywithapplicablelocalandnationalcode.
WirelessRemoteControllerPQWRHQ0FDB 7.Powerwiringcablesizemustcomplywiththeapplicablelocalandna onalcode.
8.Thisunitcomeswithadrynitrogencharge.
LGProgrammableControllerPREMTB10U 9.Thisdataisrated0 abovesealevel,with25 ofrefrigerantlineperindoorunitanda0
leveldifferencebetweenoutdoorandindoorunits.Allcapacitiesarenetwithacombinationratio
LGPremiumControllerPREMTA000 between95105%.
10.Mustfollowinstalla oninstruc onsintheapplicableLGinstalla onmanual
SimpleControllerwithMode(Black)PQRCVCL0Q
SimpleControllerwithMode(White)PQRCVCL0QW
SimpleControllerwithoutMode(Black)PQRCHCA0Q
SimpleControllerwithoutMode(White)PQRCHCA0QW
SimpleDryContact(1contact,24VACexternalpower)PDRYCB100
DryContactforEconomizerPQDSBC1
DryContactforThirdPartyThermostatPDRYCB300
WallMountedTemperatureSensorPQRSTA0
VentilationKitPTVK410+PTVK420,PTVK430
AutoElevationKitPTEGM0
PlasmaFilterKitPTPKM0 Forcontinualproductdevelopment,LGreservestheright
AuxiliaryHeaterKitPRARH1 tochangespecificationswithoutnotice.

LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.LGLifesGoodisaregisteredtrademarkofLGCorp./www.lghvac.com SB_4WayCeilingCass_ARNU48GTMC4_8_15 Page1of2


4-R20
Ceiling Cassette 4-way
5
JobName/Location:

ARNU48GTMC4
ARNU48GTMC4

840

6
48,100 Btu/hIndoorUnit

950
237

288

614(Inlet Grille)
(unit : mm)
MultiV4WayCeilingCassette

Number Name Descripition


1 Liquid pipe connection Unit size(42k, 48k):9.52
500(Air outlet Hole)
737
2 Gas pipe connection Unit size(42k, 48k):15.88
950
3 Drain pipe connection VP25(32)

25
4 Power supply connection

Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice.
5 Air discharge grill
870-920(CEILING OPENING SPACE)
786(SUSPENSION POSITION)
6 Air suction grill

300
OR LESS
Note

420
393
420
1. Unit should be installed in compliance with the installation manual
Ceiling opening in the product box.
A
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

682(SUSPENSION POSITION)

669(SUSPENSION POSITION)
870-920(CEILING OPENING SPACE)

LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.LGLifesGoodisaregisteredtrademarkofLGCorp./www.lghvac.com
475
B
71
OUTDOOR AIR INTAKE 92 92 92 92
31 35
4
(DIRECT CONNECTION) 350 REQUIRED SPACE
1
165
BRANCH DUCT

100
76

CONNECTION 500mm or more*


Date:

136
Tag#:

75
PONo.:

110
60

70
100

500mm or more*
60

500mm or more*

71
BRANCH DUCTCONNECTION

84
53.5
13- 3, 3 Hole 3 13- 3, 3 Hole

2 500mm or more*
165 10 165
Branch Duct Connection
350

A ARROW VIEW

B ARROW VIEW

CHASSIS CODE: TM

SB_4WayCeilingCass_ARNU48GTMC4_8_15
Page2of2

Potrebbero piacerti anche