Motors use almost one third of the worlds generated electricity.
So it is safe to say that reliable motor operation is crucial to our
modern way of life.
Yet millions of these motors are not run optimally. The wear smooth motor starting, and stopping, thus optimizing both
and tear associated with frequent starts and stops cause new and existing motors. As motor protectors on a global
unplanned stoppages and shortened operational lifetime. The scale, softstarters are a minor change that could have a
uptime of full-speed motors would be greatly improved if they major impact on our world allowing us to take control of the
used softstarters. As their name implies, softstarters enable processes around us.
Mining
Infrastructure
HVAC
Equipment manufacturers
Marine solutions
Process industry
Water management
Contents
ABB softstarters 1
Fieldbus communication 5
1 A softstarter from ABB offers you several values and benefits. Whether you are a
consultant, OEM, panel builder or end-user, a softstarter will add to your business
value by securing motor reliability, improving installation efficiency and increasing
application productivity.
Secure motor
Reliability
ABB softstarters help increase your motors lifetime by protecting it from electrical
stress. Starting currents are easily optimized to your load, application and motor size.
Over ten motor protection features are included to keep your motor safe from different
load and network irregularities.
Improve installation
Efficiency
Reduce your installation time and panel size by having all features you need built into
your softstarter. Our softstarters are easy to install thanks to their compact design and
many built-in features. The built-in bypass saves energy and space while reducing heat
generation. A complete motor starting solution in one unit.
Increase application
Productivity
Reduce the number of stops in your production by allowing your softstarter to do
more than just starting. Our softstarters reduce the mechanical stress on your motor
application, which will increase your uptime. Torque control, pump cleaning, motor
brake and many other features enable you to operate your process at its full potential.
For more examples of how ABB's softstarters are helping the industry, visit www.abb.com/lowvoltage/launches/pstx
1 A softstarter can do wonders with your operations. Packed with useful features, it
reduces the wear of your equipment, improve the reliability of your processes and
increase overall productivity.
Avoid running dry with underload protection Avoid unwanted movements with stand still brake
Damages due to pumps running dry can be avoided with the An idle fan that is rotating backwards, due to wind or airflow
softstarter feature underload protection. It stops the motor from another fan, can be kept still using the stand still brake.
which saves the pump from additional wear and contributes It prevents unwanted airflow and improves the control of the
to prolonging its lifetime. system without the need for an external mechanical brake.
1 There are some common issues associated with starting and stopping electrical
motors. Depending on requirement, different starting and stopping methods
can be used.
Direct-on-line starting (DOL) is the A star-delta starter reduces current and Like direct-on-line and star delta
easiest and most commonly used torque during start. The starting current starters, softstarters are used to
starting method. It is suitable for stable is about one third compared to direct- start and stop motors in full-speed
networks and mechanically stiff and on-line starting, although it also reduces applications. It eliminates common
well-dimensioned shaft systems due to the starting torque to about 25 percent. problems associated with motor starting
the high current and torque generated and stopping, including electrical
during start. surges, spikes and high inrush currents.
Star-delta is not adjustable, so if the
torque is reduced too much, the motor
DOL starting is uncontrolled, which will not start. Current peaks will happen Because it offers soft starting and
means that the motor will start with when switching from star to delta stopping, a softstarter is the optimal
maximum current and torque regardless connection. compromise between a direct-on-line
of load type. or star-delta starter and a variable
speed drive in many full-speed motor
applications.
Typical torque and current curves from starting a motor using DOL, star-delta and softstarter.
ABBs softstarter offering consists of three ranges, covering every need. The 1
products help you secure motor reliability, improve installation efficiency and
increase application productivity.
PSR The compact range PSE The efficient range PSTX The advanced range
e
n
tion
tion
ers
ctio
ion
rev
e
s
e
c
tec
eyp le
rot
ion
urr
e
tag ection otect
b
t
g fu t
rd/
ad
Bu fault p dervo tor p
un
ssi
Un verloa r ove ual c
nct
o n
wa rt co
rwa
lay on po
ce
r
t i
dp
n
tec
mo
tag
n
ion
oto and d
rloa
key nd k
o
ake ed fo
a
ng
sta
loa
rnin
i
pro
ol
bal
t
cat
l
ked tor un on
An ad tim to-trip
i
for
ect
ani
-co
Pro runtim pad
der
g
es
m
ti
pro
nd
uni
pe
d
mp
e c eterin
t
tec
olta input
n b rotec
cle
n
nt/ r pro
-to
i
rt
uag
e
con
ea
dp
ws
mm
un
t
sta
qu ll brak
e-
ble
s
t ra
tar
tac l disp
o
e li rol
sto ersa
p m BA
ut
C/P ating
mp
s
r
ge/
Ov ad tim
g
ypa
cm
utp
o
ym
t
Dy ith slo
ont
es
rd
Dia mma
s
Gra delta
Eve s co
Sta ic br
mit
Jog ode
e
Cu t limi
Ele t limi
Ele e lan
age
Vol
C
rot
l pu
10
stic
l
c
rev
hab
dP
Ma art
Mu log
me
a
e
enc
r fa
go
i
oni
icit
t
T
c
h
t
u
gno
nam
nua
l
t
n
n
gra
i
l
erlo
erlo
al o
l vo
ase
ph
-
der
ks
ltip
ate
ldb
tor
tor
nd
ide
erv
we
ctr
ctr
alo
ilt-i
qu
qu
nt
rre
rre
rre
rth
Loc
Lim
Mo
Mo
Kic
Tor
Tor
Ful
Co
Cu
Fie
Cu
Cu
Ins
Du
Ov
De
Ov
PT
Ph
Se
Ea
PSR o
PSE o o
PSTX 17
1 4 5 6 8
1 Softstarter
Soft start and stop with reduced
3
current
Features to improve process on
off
productivity 7 8
2
Detachable kepyad for front
door mounting on a panel
ATEX
A separate ATEX approved overload relay from ABB has to be used
together with a line contactor. This overload relay will replace the built-in
EOL in the softstarter and has an ATEX approved tripping curve.
Select softstarter according to normal or heavy-duty start depending on
application and line contactor and overload relay with type 2 coordination.
Terminal blocks
SNK series
6 PLC 800M 7 Terminal blocks SNK range 8 Line contactor AF
Automatic control Easy installation of control Isolation at stop
Remote communication wires Isolation at faults
Emergency stop
Back-up DOL starter
303 O 0
O
303
O O
O
C A
D
B A B
Multi-language manual Terminal kit Cable and mounting kit for detachable keypad
PSR3 PSR105 - -
PSE18 PSE370 -
PSTX30 PSTX1250
The table below shows the certifications and approvals for ABBs softstarters.
For other certifications and/or approvals, please contact ABB. 1
Abbreviation CE cULus CCC EAC ANCE C-tick ABS DNV GL Lloyds CCS PRS Class
approved in EU Canada China Russia Mexico Australia Register NK
USA
Introduction 2/2
Overview 2/4
Accessories 2/6
Dimensions 2/8
The PSR softstarter is the most compact of all the softstarter ranges which
2
allows for design of compact starting equipment. A PSR together with a
manual motor starter makes up a far more compact starting solution than a
star-delta starter, and with the built-in bypass, the energy losses inside the
softstarter are highly reduced.
Reduce the electrical stresses and keep the motor protected with the MMS
Secure motor
The PSR reduces the starting current for the motor. The possibility to connect it to
Reliability the manual motor starter makes it possible to build a compact and complete starting
solution with overload and short-circuit protection.
Saving time and money with built-in bypass and easy set-up
Improve installation
On the PSR, the bypass is built in and verified by ABB, saving you time during
Efficiency installation and space in your panel. Set-up is done through three potentiometers
making it very fast and easy.
LED indicators
PSR has LED indicators for On/Ready and
Run/Top of ramp.
Settings
2 Step down
1 Start = 1...20 sec
1 3 Uini
2 Stop = 0...20 sec - including the step down voltage
3 Uend
Step down = 2% reduction for each second increased stop ramp 2
Normal start PSR3 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45 PSR60 PSR72 PSR85 PSR105
In-line connected
(400 V) kW 1.5 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55
IEC, max. A 3.9 6.8 9 12 16 25 30 37 45 60 72 85 105
(440-480 V) hp 2 3 5 7.5 10 15 20 25 30 40 50 60 75
UL, max. FLA 3.4 6.1 9 11 15.2 24.2 28 34 46.2 59.4 68 80 104
400 V, 40 C
Using manual motor Manual motor starter (50 kA)
starters type 1 coordina-
tion will be achieved 1) MS116 MS132 MS450 MS495
1)
This is an example of coordination. For more examples see: applications.it.abb.com/SOC
Compressor
Conveyor belt (short) 2
Elevator
PSR3 ... PSR16 For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
new.abb.com/low-voltage/products/softstarters
1SFC132072V0001
Pe Pe Pe Ie Pe Pe Pe Pe FLA
kW kW kW A hp hp hp hp A kg (lb)
0.75 1.5 2.2 3.9 0.5 0.75 2 2 3.4 PSR3-600-70 1SFA896103R7000 0.45 (0.99)
1.5 3 4 6.8 1 1.5 3 5 6.1 PSR6-600-70 1SFA896104R7000 0.45 (0.99)
PSR37 ... PSR45 2.2 4 4 9 2 2 5 7.5 9 PSR9-600-70 1SFA896105R7000 0.45 (0.99)
3 5.5 5.5 12 3 3 7.5 10 11 PSR12-600-70 1SFA896106R7000 0.45 (0.99)
4 7.5 7.5 16 3 5 10 10 15.2 PSR16-600-70 1SFA896107R7000 0.45 (0.99)
5.5 11 15 25 7.5 7.5 15 20 24.2 PSR25-600-70 1SFA896108R7000 0.65 (1.43)
7.5 15 18.5 30 7.5 10 20 25 28 PSR30-600-70 1SFA896109R7000 0.65 (1.43)
7.5 18.5 22 37 10 10 25 30 34 PSR37-600-70 1SFA896110R7000 1.00 (2.20)
1SFC132028V0001
Connection kit
2 PSR3 ... PSR16 with MS116 or MS132
PSR25 ... PSR30 with MS132-12 ... MS132-32
PSR16-MS116
PSR30-MS132
1SFA896211R1001
1SFA896212R1001
1
1
0.022
0.040
(0.049)
(0.088)
PSR16-MS116 PSR30-MS132 PSR37 ... PSR45 with MS450 PSR45-MS450 1SFA896213R1001 1 0.034 (0.075)
PSR60 ... PSR105 with MS495 PSR105-MS495 1SAM501903R1001 1 0.050 (0.110)
1SFC132208F0002
1SFC132170F0002
1SFC132325F0002
Softstarter types PSR3 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45 PSR60 PSR72 PSR85 PSR105
Rated insulation voltage Ui 600 V
Rated operational voltage Ue 208...600 V +10%/-15%, 50/60 Hz 5%
Rated control supply voltage Us 100...240 V AC, 50/60Hz 5% or 24 V AC/DC, +10%/-15%,
Starting capacity at Ie 4 x Ie for 6 sec. 2
Number of starts per hour See table below for details
standard 10 1)
with aux. fan 20 1)
Ambient temperature
during operation -25...+60 C (-13...+140 F) 2)
1SFB536147G1204
PSR25 PSR30
1SFB536147G1204
2
1SFC132226F0001
1SFC132228F0001
1SFC132227F0001
PSR25 ... PSR45
With MMS With MMS and auxiliary contact With fuses, contactor and O.L.
1SFC132231F0001
1SFC132229F0001
1SFC132230F0001
1SFC132233F0001
1SFC132234F0001
Introduction 3/2
3
Overview 3/4
Accessories 3/8
Dimensions 3/12
The PSE has been designed to meet the most common requirements from the
water segment and is specialized on pump operation. It combines the requested
protections with a very compact design and built-in bypass. Remote operation
with external keypad or over fieldbus is available as an option.
3
Two-phase controlled Coated PCBA protecting from dust,
Operational voltage: 208...600 V AC moist and corrosive atmosphere
Wide rated control supply voltage: Illuminated display that uses symbols to
100...250 V AC, 50/60 Hz become language neutral
Rated operational current: 18...370 A External keypad rated IP66 (Type 1, 4X,12)
Voltage ramp and torque control for both as an option
start and stop Fieldbus communication with FieldBusPlug
Current limit adapter and the FieldBusPlug
Kick-start Analog output for display of motor current
Built-in bypass for energy saving and Electronic overload protection
easy installation Underload protection
Locked rotor protection
Saving time and money with built-in bypass and compact design
Improve installation
On the PSE, the bypass is built in and verified by ABB, saving you time during
Efficiency installation and space in your panel. The keypad is language neutral and illuminated
for easy set-up and operation in field. The compact design makes installation fast
and easy.
Productivity special torque stop ramp that is designed together with a pump manufacturer to
eliminate water hammering in an optimal way.
Screw mounting
PSE is fast easy to install by using screw mounting.
LED indicators
Illuminated and language-neutral
Green ready LED display with icons
Flashing - Suppy available The display on PSE uses icons for
Steady - Main available fast and easy set-up of parameters.
Green run LED Each icon indicates a different
Flashing - Ramping up/down parameter to set and makes
Steady - TOR navigation and setting of parameters
easy. Set-up is done by using the
Yellow protection LED
four buttons on the keypad.
Red fault LED
Normal start
PSE18 PSE25 PSE30 PSE37 PSE45 PSE60 PSE72 PSE85 PSE105
In-line connected
(400 V) kW 7.5 11 15 18.5 22 30 37 45 55
IEC, max. A 18 25 30 37 45 60 72 85 106
(440-480 V) hp 10 15 20 25 30 40 50 60 75
UL, max. FLA 18 25 28 34 42 60 68 80 104
400 V, 40 C
MCCB (35 kA)
Using MCCB only, type 1 T2N160 T3N250
coordination will be achieved 1) MCCB (50 kA)
T2S160 T3S250
To achieve type 2 coordination, Fuse protection (85 kA), Semiconductor fuses, Bussmann
semi-conductor fuses must be
used 1) 170M1563 170M1564 170M1566 170M1567 170M1568 170M1569 170M1571 170M1572 170M3819
1)
This is an example of coordination. For more examples see: applications.it.abb.com/SOC
Normal start
PSE142 PSE170 PSE210 PSE250 PSE300 PSE370
In-line connected
(400 V) kW 75 90 110 132 160 200
IEC, max. A 143 171 210 250 300 370
(440-480 V) hp 100 125 150 200 250 300
UL, max. FLA 130 169 192 248 302 361
400 V, 40 C
MCCB (35 kA)
Using MCCB only, type 1 T3N250 T4N320 T5N400 T5N630
coordination will be achieved 1) MCCB (50 kA)
T3S250 T4S320 T5S400 T5S630
1)
This is an example of coordination. For more examples see: applications.it.abb.com/SOC
Description
Selection table for normal start. Typical applications:
Bow thruster
Centrifugal pump
1SFC132001V0001
Compressor
Conveyorbelt (short)
Elevator
3 PSE18 ... PSE105
Escalator
If more than 10 starts/h, select one size larger than the standard selection.
For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
new.abb.com/low-voltage/products/softstarters
Description
Selection table for heavy-duty start. Typical applications:
Centrifugal fan
Conveyor belt (long)
1SFC132001V0001
Crusher
Mill
Mixer
Stirrer 3
PSE18 ... PSE105
If more than 10 starts/h, select one size larger than the standard selection.
For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
new.abb.com/low-voltage/products/softstarters
For softstarter type Wire range Tightening Type Order code Pkg Weight
1SFT98099_095C2
3
For softstarter type Wire range Tightening Type Order code Pkg Weight
1SFT98099-01C1
mm2 Nm kg (lb)
Cable connectors for Al and Cu cables
PSE142 PSE170 95...185 31 1SDA054988R1 3 0.078 (0.172)
PSE210 PSE370 185...240 43 1SDA055020R1 3 0.133 (0.293)
1SFT98000_011C3
kg (lb)
1SFT98099_125
Terminal shrouds
PSE142 ... PSE170, short for use with cable clamps 2 LT185-AC 1SFN124701R1000 2 0.050 (0.110)
PSE142 ... PSE170, long for use with compression lugs 2 LT185-AL 1SFN124703R1000 2 0.220 (0.485)
LT ... -AC LT ... -AL PSE210 ... PSE370, short for use with cable clamps 2 LT300-AC 1SFN125101R1000 2 0.070 (0.154)
PSE210 ... PSE370, long for use with compression lugs 2 LT300-AL 1SFN125103R1000 2 0.280 (0.617)
1SFC132328F0002
qty (1 pce)
kg (lb)
FieldBusPlug connection accessory
PSE18 ... PSE370 PS-FBPA 1SFA896312R1002 1 0.060 (0.132)
PS-FBPA
Time (s)
10 000
3
1000
100
Class 30
10 Class 20
Class 10
Class 10 A
1SFC132134F0201
0
0 1 2 3 4 5 6 7 8
Tripping curves for electronic overload protection (cold) for PSE and PSTX. Current (x Ie)
5 5
E1858D
E1859D
8.5
10.2
5 mm (0,20 in)
13 mm
(0,51 in) 17,5 mm (0,67 in)
(1,57 in)
40 mm
6,5 mm (0,24 in)
(1,46 in)
37 mm
1SFC132260F0001
1SFC132259F0001
1SFC132266F0001
3 mm (0,12 in)
35 mm 35 mm
(1,38 in) (1,38 in)
3 mm (0,12 in)
43,75 mm 43,75 mm
80 mm (3,15 in)
(1,69 in) (1,69 in)
26 mm
88 mm (3,46 in) (1,02 in)
27,4 mm
(1,06 in)
L1 L1
L2 L2
L3 L3
N N
L N L N
MCCB
Start Stop Start Stop 3
8 9 11 8 9 11
Start Start
Stop KM1 Stop
NC NO NC NO
2T1 4T2 6T3 3 4 5 6 7 2T1 4T2 6T3 3 4 5 6 7
1SFC132274F0001, rev.2
1SFC132237F0001, rev.3
U V W U V W
M M
3 3
Introduction 4/2
Overview 4/4
Dimensions 4/16
The PSTX combines many years of research and product development with
extensive knowledge of application specific requirements and needs.
It is our latest advancement in motor control and protection and
adds new functionality and increased reliability.
Reliability
only one unit and is able to handle both load standard, dual and ramp. This gives you full
and network irregularities. PT-100, earth fault control of your motor during start. It also allows
protection and over/under voltage protection you to use your motor in weaker networks.
along with many other functions keep your
motor safer than ever.
Built-in bypass saves time and energy Easy-to-use and detachable keypad
Improve installation When reaching full speed, the PSTX will A user-friendly and clear display saves you
Easy to learn
A large graphical display along with built-in
assistants make learning how to handle the
PSTX fun and simple. The interface resembles
Customizable other interfaces from ABB which will stream-
The PSTX has 17 pre-installed languages line and help with training of field personnel.
along with options to customize your own
specific home screens (up to seven different).
You can use your customized home screens
to show status information important to your
process and hide information that is not. Detachable
The PSTX comes with a detachable keypad
as standard. It can be placed on your panel
door, meaning you do not have to interrupt
your process in order to read status informa-
tion or to change settings.
Normal start PSTX30 PSTX37 PSTX45 PSTX60 PSTX72 PSTX85 PSTX105 PSTX142 PSTX170
4 In-Line connected
(400 V) kW 15 18.5 22 30 37 45 55 75 90
IEC, max. A 30 37 45 60 72 85 106 143 171
(440-480 V) hp 20 25 30 40 50 60 75 100 125
UL, max. FLA 28 34 42 60 68 80 104 130 169
400 V, 40 C
Using manual motor MCCB (50 kA)
starter or MCCB, type
1 coordination will be XT2S160 XT4S250
achieved. 1)
Using gG fuses, type Fuse protection (80 kA), Semiconductor fuses, Bussmann
1 coordination will be
achieved. To achieve
type 2 coordination, 170M1567 170M1568 170M1569 170M1571 170M1572 170M3819 170M5810 170M5812
semiconductor fuses
must be used. 1)
1)
This is an example of coordination. For more examples see: applications.it.abb.com/SOC
Normal start PSTX210 PSTX250 PSTX300 PSTX370 PSTX470 PSTX570 PSTX720 PSTX840 PSTX1050 PSTX1250
In-Line connected 4
(400 V) kW 110 132 160 200 250 315 400 450 560 710
IEC, max. A 210 250 300 370 470 570 720 840 1050 1250
(440-480 V) hp 150 200 250 300 400 500 600 700 900 1000
UL, max. FLA 192 248 302 361 480 590 720 840 1062 1250
400 V, 40 C
Using manual motor MCCB (50 kA)
starter or MCCB, type
1 coordination will be T4S320 T5S400 T5S630 T7S800 T7S1250 E2.2N 2000
achieved. 1)
Using gG fuses, type Fuse protection (80 kA), Semiconductor fuses, Bussmann
1 coordination will be
achieved. To achieve
type 2 coordination, 170M5812 170M5813 170M6812 170M6813 170M6814 170M8554 170M6018 170M6020 170M6021
semiconductor fuses
must be used. 1)
1)
This is an example of coordination. For more examples see: applications.it.abb.com/SOC
Description
Selection table for normal start. Typical applications:
1SFC132038V0001
Bow thruster
Centrifugal pump
Compressor
Conveyor belt (short)
PSTX30 ... PSTX105
Elevator
For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
1SFC132053V0001
new.abb.com/low-voltage/products/softstarters
4
Rated operational voltage Ue, 208...600 V
Rated control supply voltage Us, 100...250 V AC, 50/60 Hz
PSTX142 ... PSTX170 IEC UL/CSA Type Order code Weight
Rated operational Rated operational (1 pce)
power current power current
400 V 500 V 690 V 200 / 220 / 440 / 550 /
208 V 240 V 480 V 600 V
Pe Pe Pe Ie Pe Pe Pe Pe FLA
1SFC132058V0001
kW kW kW A hp hp hp hp A kg (lb)
15 18.5 - 30 7.5 10 20 25 28 PSTX30-600-70 1SFA898103R7000 6.10 (13.45)
18.5 22 - 37 10 10 25 30 34 PSTX37-600-70 1SFA898104R7000 6.10 (13.45)
22 25 - 45 10 15 30 40 42 PSTX45-600-70 1SFA898105R7000 6.10 (13.45)
30 37 - 60 20 20 40 50 60 PSTX60-600-70 1SFA898106R7000 6.10 (13.45)
PSTX210 ... PSTX370 37 45 - 72 20 25 50 60 68 PSTX72-600-70 1SFA898107R7000 6.10 (13.45)
45 55 - 85 25 30 60 75 80 PSTX85-600-70 1SFA898108R7000 6.10 (13.45)
55 75 - 106 30 40 75 100 104 PSTX105-600-70 1SFA898109R7000 6.10 (13.45)
75 90 - 143 40 50 100 125 130 PSTX142-600-70 1SFA898110R7000 9.60 (21.16)
90 110 - 171 50 60 125 150 169 PSTX170-600-70 1SFA898111R7000 9.60 (21.16)
110 132 - 210 60 75 150 200 192 PSTX210-600-70 1SFA898112R7000 12.70 (27.99)
132 160 - 250 75 100 200 250 248 PSTX250-600-70 1SFA898113R7000 12.70 (27.99)
1SFC132098V0001
160 200 - 300 100 100 250 300 302 PSTX300-600-70 1SFA898114R7000 12.70 (27.99)
200 257 - 370 125 150 300 350 361 PSTX370-600-70 1SFA898115R7000 12.70 (27.99)
250 315 - 470 150 200 400 500 480 PSTX470-600-70 1SFA898116R7000 25.00 (55.12)
315 400 - 570 200 200 500 600 590 PSTX570-600-70 1SFA898117R7000 25.00 (55.12)
400 500 - 720 250 300 600 700 720 PSTX720-600-70 1SFA898118R7000 46.20 (101.85)
PSTX470 ... PSTX570
450 600 - 840 300 350 700 800 840 PSTX840-600-70 1SFA898119R7000 46.20 (101.85)
560 730 - 1050 400 450 900 1000 1062 PSTX1050-600-70 1SFA898120R7000 64.20 (141.54)
710 880 - 1250 400 500 1000 1200 1250 PSTX1250-600-70 1SFA898121R7000 64.70 (142.64)
250 315 450 470 150 200 400 500 480 PSTX470-690-70 1SFA898216R7000 25.00 (55.12)
315 400 560 570 200 200 500 600 590 PSTX570-690-70 1SFA898217R7000 25.00 (55.12)
400 500 710 720 250 300 600 700 720 PSTX720-690-70 1SFA898218R7000 46.20 (101.85)
450 600 800 840 300 350 700 800 840 PSTX840-690-70 1SFA898219R7000 46.20 (101.85)
560 730 1000 1050 400 450 900 1000 1062 PSTX1050-690-70 1SFA898220R7000 64.20 (141.54)
PSTX1050 ... PSTX1250
710 880 1200 1250 400 500 1000 1200 1250 PSTX1250-690-70 1SFA898221R7000 64.70 (142.64)
Description
Selection table for heavy-duty start. Typical applications:
1SFC132038V0001
Centrifugal fan
Conveyor belt (long)
Crusher
Mill
PSTX30 ... PSTX105
Mixer
Stirrer
For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
1SFC132053V0001
new.abb.com/low-voltage/products/softstarters 4
Rated operational voltage Ue, 208...600 V
PSTX142 ... PSTX170 Rated control supply voltage Us, 100...250 V AC, 50/60 Hz
IEC UL/CSA Type Order code Weight
Rated operational Rated operational (1 pce)
power current power current
400 V 500 V 690 V 200 / 220 / 440 / 550 /
208 V 240 V 480 V 600 V
1SFC132058V0001
Pe Pe Pe Ie Pe Pe Pe Pe FLA
kW kW kW A hp hp hp hp A kg (lb)
11 15 - 22 5 7.5 15 20 25 PSTX30-600-70 1SFA898103R7000 6.10 (13.45)
15 18.5 - 30 7.5 10 20 25 28 PSTX37-600-70 1SFA898104R7000 6.10 (13.45)
18.5 22 - 37 10 10 25 30 34 PSTX45-600-70 1SFA898105R7000 6.10 (13.45)
PSTX210 ... PSTX370 22 25 - 45 10 15 30 40 42 PSTX60-600-70 1SFA898106R7000 6.10 (13.45)
30 37 - 60 20 20 40 50 60 PSTX72-600-70 1SFA898107R7000 6.10 (13.45)
37 45 - 72 20 25 50 60 68 PSTX85-600-70 1SFA898108R7000 6.10 (13.45)
45 55 - 85 25 30 60 75 80 PSTX105-600-70 1SFA898109R7000 6.10 (13.45)
55 75 - 106 30 40 75 100 104 PSTX142-600-70 1SFA898110R7000 9.60 (21.16)
75 90 - 143 40 50 100 125 130 PSTX170-600-70 1SFA898111R7000 9.60 (21.16)
90 110 - 171 50 60 125 150 169 PSTX210-600-70 1SFA898112R7000 12.70 (27.99)
1SFC132098V0001
110 132 - 210 60 75 150 200 192 PSTX250-600-70 1SFA898113R7000 12.70 (27.99)
132 160 - 250 75 100 200 250 248 PSTX300-600-70 1SFA898114R7000 12.70 (27.99)
160 200 - 300 100 100 250 300 302 PSTX370-600-70 1SFA898115R7000 12.70 (27.99)
200 257 - 370 125 150 300 350 361 PSTX470-600-70 1SFA898116R7000 25.00 (55.12)
PSTX470 ... PSTX570 250 315 - 470 150 200 400 500 480 PSTX570-600-70 1SFA898117R7000 25.00 (55.12)
315 400 - 570 200 200 500 600 590 PSTX720-600-70 1SFA898118R7000 46.20 (101.85)
400 500 - 720 250 300 600 700 720 PSTX840-600-70 1SFA898119R7000 46.20 (101.85)
450 600 - 840 300 350 700 800 840 PSTX1050-600-70 1SFA898120R7000 64.20 (141.54)
560 730 - 1050 400 450 900 1000 1062 PSTX1250-600-70 1SFA898121R7000 64.70 (142.64)
160 200 257 300 100 100 250 300 302 PSTX370-690-70 1SFA898215R7000 12.70 (27.99)
200 257 355 370 125 150 300 350 361 PSTX470-690-70 1SFA898216R7000 25.00 (55.12)
250 315 450 470 150 200 400 500 480 PSTX570-690-70 1SFA898217R7000 25.00 (55.12)
315 400 560 570 200 200 500 600 590 PSTX720-690-70 1SFA898218R7000 46.20 (101.85)
400 500 710 720 250 300 600 700 720 PSTX840-690-70 1SFA898219R7000 46.20 (101.85)
PSTX1050 ... PSTX1250
450 600 800 840 300 350 700 800 840 PSTX1050-690-70 1SFA898220R7000 64.20 (141.54)
560 730 1000 1050 400 450 900 1000 1062 PSTX1250-690-70 1SFA898221R7000 64.70 (142.64)
Description
Selection table for normal start. Typical applications:
Bow thruster
1SFC132038V0001
Centrifugal pump
Compressor
Conveyor belt (short)
PSTX30 ... PSTX105
Elevator
For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
new.abb.com/low-voltage/products/softstarters
1SFC132053V0001
184 250 - 360 100 125 250 300 332 PSTX210-600-70 1SFA898112R7000 12.70 (27.99)
220 295 - 430 150 150 350 450 429 PSTX250-600-70 1SFA898113R7000 12.70 (27.99)
257 355 - 515 150 200 450 500 523 PSTX300-600-70 1SFA898114R7000 12.70 (27.99)
355 450 - 640 200 250 500 600 625 PSTX370-600-70 1SFA898115R7000 12.70 (27.99)
450 600 - 814 250 300 600 700 830 PSTX470-600-70 1SFA898116R7000 25.00 (55.12)
PSTX470 ... PSTX570
540 700 - 987 300 350 700 800 1020 PSTX570-600-70 1SFA898117R7000 25.00 (55.12)
710 880 - 1247 400 500 1000 1200 1240 PSTX720-600-70 1SFA898118R7000 46.20 (101.85)
800 1000 - 1455 500 600 1200 1500 1450 PSTX840-600-70 1SFA898119R7000 46.20 (101.85)
1000 1250 - 1810 600 700 1500 1800 1830 PSTX1050-600-70 1SFA898120R7000 64.20 (141.54)
1200 1500 - 2160 800 900 1800 2000 2160 PSTX1250-600-70 1SFA898121R1000 64.70 (142.64)
1SFC132103V0001
220 295 400 430 150 150 350 450 429 PSTX250-690-70 1SFA898213R7000 12.70 (27.99)
257 355 500 515 150 200 450 500 523 PSTX300-690-70 1SFA898214R7000 12.70 (27.99)
355 450 600 640 200 250 500 600 625 PSTX370-690-70 1SFA898215R7000 12.70 (27.99)
450 600 800 814 250 300 600 700 830 PSTX470-690-70 1SFA898216R7000 25.00 (55.12)
540 700 960 987 300 350 700 800 1020 PSTX570-690-70 1SFA898217R7000 25.00 (55.12)
PSTX1050 ... PSTX1250
710 880 1200 1247 400 500 1000 1200 1240 PSTX720-690-70 1SFA898218R7000 46.20 (101.85)
800 1000 1400 1455 500 600 1200 1500 1450 PSTX840-690-70 1SFA898219R7000 46.20 (101.85)
1000 1250 1700 1810 600 700 1500 1800 1830 PSTX1050-690-70 1SFA898220R7000 64.20 (141.54)
1200 1500 2000 2160 800 900 1800 2000 2160 PSTX1250-690-70 1SFA898221R7000 64.70 (142.64)
Description
Selection table for heavy-duty start. Typical applications:
1SFC132038V0001
Centrifugal fan
Conveyor belt (long)
Crusher
Mill
PSTX30 ... PSTX105
Mixer
Stirrer
For a more precise selection, use the online softstarter selection tool available by scanning the shown QR
code or using the selection tool available on:
1SFC132053V0001
new.abb.com/low-voltage/products/softstarters 4
160 200 - 300 75 100 200 250 292 PSTX210-600-70 1SFA898112R7000 12.70 (27.99)
184 250 - 360 100 125 250 300 332 PSTX250-600-70 1SFA898113R7000 12.70 (27.99)
220 295 - 430 150 150 350 450 429 PSTX300-600-70 1SFA898114R7000 12.70 (27.99)
257 355 - 515 150 200 450 500 523 PSTX370-600-70 1SFA898115R7000 12.70 (27.99)
PSTX470 ... PSTX570 355 450 - 640 200 250 500 600 625 PSTX470-600-70 1SFA898116R7000 25.00 (55.12)
450 600 - 814 250 300 600 700 830 PSTX570-600-70 1SFA898117R7000 25.00 (55.12)
540 700 - 987 300 350 700 800 1020 PSTX720-600-70 1SFA898118R7000 46.20 (101.85)
710 880 - 1247 400 500 1000 1200 1240 PSTX840-600-70 1SFA898119R7000 46.20 (101.85)
800 1000 - 1455 500 600 1200 1500 1450 PSTX1050-600-70 1SFA898120R7000 64.20 (141.54)
1000 1250 - 1810 600 700 1500 1800 1830 PSTX1250-600-70 1SFA898121R7000 64.70 (142.64)
220 295 400 430 150 150 350 450 429 PSTX300-690-70 1SFA898214R7000 12.70 (27.99)
257 355 500 515 150 200 450 500 523 PSTX370-690-70 1SFA898215R7000 12.70 (27.99)
355 450 600 640 200 250 500 600 625 PSTX470-690-70 1SFA898216R7000 25.00 (55.12)
450 600 800 814 250 300 600 700 830 PSTX570-690-70 1SFA898217R7000 25.00 (55.12)
540 700 960 987 300 350 700 800 1020 PSTX720-690-70 1SFA898218R7000 46.20 (101.85)
PSTX1050 ... PSTX1250
710 880 1200 1247 400 500 1000 1200 1240 PSTX840-690-70 1SFA898219R7000 46.20 (101.85)
800 1000 1400 1455 500 600 1200 1500 1450 PSTX1050-690-70 1SFA898220R7000 64.20 (141.54)
1000 1250 1700 1810 600 700 1500 1800 1830 PSTX1250-690-70 1SFA898221R7000 64.70 (142.64)
For softstarter type Wire range Tightening Type Order code Pkg Weight
torque max. qty (1 pce)
mm 2
Nm kg (lb)
Cable connectors for Cu cables
1SFT98099_095C2
1SFT98099_125
PSTX210 ... PSTX370, long and deep for use with 2 LT370-30D 1SFN125406R1000 2 0.150 (0.331)
extending cable clamps, ATK300/2 and OZXB4
PSTX470 ... PSTX570 , short for use with cable clamps 2 LT460-AC 1SFN125701R1000 2 0.100 (0.220)
PSTX470 ... PSTX570, long for use with 2 LT460-AL 1SFN125703R1000 2 0.800 (1.764)
LT ... -AC LT ... -AL compression lugs
LT ... -C LT ... -L PSTX720 ... PSTX840, short for use with cable clamps 2 LT750-AC 1SFN126101R1000 2 0.120 (0.265)
PSTX720 ... PSTX840, long for use with 2 LT750-AL 1SFN126103R1000 2 0.825 (1.819)
compression lugs
PSTX has an integrated electronic overload protection that can be set to four different tripping classes.
Below you find a curve for each tripping class in cold state.
Time (s)
10 000
1000
4
100
Class 30
10 Class 20
Class 10
Class 10 A
1SFC132134F0201
0
0 1 2 3 4 5 6 7 8
Tripping curves for electronic overload protection (cold) for PSE and PSTX. Current (x Ie)
For all functions and features see installation and commissioning manual, 1SFC132081M0201 available on new.abb.com/low-voltage/products/softstarters.
Main terminals PSTX30 ... PSTX105 PSTX142 ... PSTX170 PSTX210 ... PSTX370 PSTX470 ... PSTX570 PSTX720 ... PSTX1050 PSTX1250
50
27
25 8
20 40
17.5 6
5 6
5 22.5
22.5
E1861D
E1860D
E1859D
6.5
E1858D
10.5 6.5 12.5 13
10.2
8.5
5 mm (0,2 in)
5 mm (0,2 in)
360,5 mm (14,1 in)
377 mm (14,8 in)
4
90,5 mm (3,6 in)
5 mm (0,2 in)
360,5 mm (14,1 in)
13 mm (0,5 in) 6x
377 mm (14,8 in)
3 mm (0,1 in)
113.8 110
(4.48) (4.43)
75 10.75
(2.95) (0.42)
38.3
37.5 R4 (1.51)
(1.48) (R0.16)
90.1
(3.55)
25
(0.98)
24 (0.94)
23
(0.91)
6 mm (0.2 in) 6x
8 (6x) mm
(0.3 in)
150.5 mm (5.93 in)
(14.5 in)
6 mm (0.2 in) 6x
262.82 mm (10.3 in)
282.15 mm (11.1 in)
493 mm (19.4 in)
466 mm (18.3 in)
(14.5 in)
369 mm
63 mm (25 in)
58.2 mm (2.3 in) 6x
25 mm (0.9 in) 6x
13 (4x) 13 (4x)
40 (6x) mm
(1.57 in) 12.5 (6x) 13 (4x)
408.9 mm (16.1 in) 407 mm
(16 in)
PSTX1250
133.5(2x) mm 301.5 mm
(5.2 in) (11.8 in)
72 mm (2.8 in) 4x 7 mm (0.276 in) 4x 435 mm (17.1 in)
301.5 mm
(11.8 in)
72 mm (2.8 in) 4x 7 mm (0.276 in) 4x 435 mm (17.1 in)
515 mm (20.2 in)
565 mm (22.2 in)
485 mm (19 in)
(14.5 in)
50 (6x) mm 13 (18x)
(1.9 in)
407 mm
13 (18x) (16 in)
407 mm
(16 in)
1L1
3L2
5L3
Ct1
Ct2
22 Ct3
21
20 +24V
Internal control voltage 19
19 GND
18
18 DGND
Stop Start 20, 21 17 In2
4 13
14
16
15
In1
In0 Low Voltage Board
14 Stop
V1
13 Start V2
12 HMI
Internal control voltage
19
11
18 K6
3L2
1L1
5L3
10 Internal
20, 21 V3
Bypass
9 V4 K2
13 Contactor
4T2
2T1
6T3
14 8 K5
Stop Start 7
6 V5
5 V6
K4
External control voltage 24V DC 4
18
3
L Bypass*
13 2 N 100-250V
1 L 50/60 Hz
14
Stop Start
2T1
4T2
6T3
23, 24 25, 26, 27 28 29 30
Anybus Fieldbus Modbus PTC +24V Analog out GND
Extension I/O PT100
U V W
Anybus
M
* Only on PSTX470 ... PSTX1250
UL circuit diagram
INCOMING LINES
OPTIONAL HOA WI RING A B C
OFF
HAND CHFU CHFU
AUTO
H1 H2 H3 H4
23 24 CXFU CCT
13 14
STOP START
21 22 13 14
STOP 13
START 14
+24V 20, 21
DGND 18
GND 19
1 2 3 13 14 15 16 17 18 19 20 21 22 L1 L2 L3
L N L
In1
In0
In2
DGND
GND
Start
Stop
+24V
Bypass*
100-250V
50/60 Hz
K4 K5 K6
Relay Relay Relay K1 K2 K3
Modbus PTC Analog
Extension I/O PT100 +24V out GND
4 5 6 7 8 9 10 11 12 Anybus Fieldbus
23 24 25, 26, 27 28 29 30
T1 T2 T3
Anybus
MTR MTR
O E
1 4 7 10
1/L1
3/L2
5/L3
Soft starter
Anybus
PSTX Com 1 K1
2/T1
4/T2
6/T3
I E K7 21
+ 24V Com 2
4
20
Default:Top of ramp
23 +(B)
Com 3
19 GND
Default: Event
HMI
Default: Run
K7
17 In2 25 T1
Temp In
16 In1 26 T2 PSTX
27 T3
15 In0
28 +24V
Analog out
14 Stop
13 Start 29 +
30 GND
K7 K1
W1
V1
U1
Coil consumption for main contactors.
Pull-in max 15A
3-wire control Holding max 1.5A
M
20 +24V If the pull-in or holding values are higher, the
19 GND main contactors must be controlled via an
auxiliary contactor.
O E 18 DGND
I E 14 Stop
13 Start
Inside-delta connected with contactor and fuses Bjrn Johansson Approved RE Application diagram
Fieldbus communication
Introduction 5/2
PSR, PSE and PSTX softstarters can be connected to a fieldbus network for
monitoring and control. All major industrial fieldbus protocols are covered with
different accessories making the installation very flexible.
1 4 5
Protocols with FieldBusPlug
5 - Modbus-RTU
- Profibus
- DeviceNet
- Modbus TCP (only PSE)
Integrated protocol
- Modbus-RTU
1 Softstarter PSR
2 Softstarter PSE
3 3 Softstarter PSTX
4 FieldBusPlug adapter
5 FieldBusPlug
6 Anybus
DeviceNet
5
1SFC132118V0001
EtherNet/IP (1-port)
Modbus TCP (1-port)
1SFC132119V0001
EtherNet/IP (2-port)
Modbus TCP (2-port)
Profinet (2-port)
DeviceNet FieldBusPlug
Ready-made DeviceNet fieldbus interface with various cable lengths
Applicable on all FBP motor starters and other devices
Degree of protection IP65, diagnostic LED
5 Modbus-RTU FieldBusPlug
Ready-made Modbus-RTU fieldbus interface with various cable lengths
Applicable on all FBP motor starters and other devices
Degree of protection IP65, diagnostic LED
Profibus DP FieldBusPlug
Ready-made Profibus DP fieldbus interface with various cable lengths.
Supports PROFIBUS DP V0 and V1
Applicable on all FBP motor starters and other devices
Degree of protection IP65, diagnostic LED
PDP22-FBP
Profibus DP FieldBusPlug for four devices 5
PDQ22 is a member of the ABBs FieldBusPlug family of bus connectors. It allows the connection
of up to four devices to Profibus DP by just using one Profibus node access. This allows a cost
efficient device integration for devices that are located physically nearby. PDQ22 supports DP-V0
and DP-V1. The degree of protection is IP66. There are separate diagnosis LEDs for bus and device
status.
Note that the accessory PDQ22-FBP only works with the PSR and PSE softstarter.
Designation Type Order code Pkg Weight
qty (1 pce)
kg (lb)
Quadruple bus connector PDQ22-FBP 1SAJ240200R0050 1 0.20 (0.44)
2CDC341048F0006
Configuration software
This cable and software can be used for setup and comissioning of the softstarter as well as to
keep back-up of the parameter settings.
DNM11-FBP.0
DeviceNet and Modbus-RTU termination resistor
Designation Type Order code Pkg Weight
DNF11-FBP.0
qty (1 pce)
kg (lb)
Termination Resistor, 120 Ohm DNR11-FBP.120 1SAJ923007R0001 1 0.02 (0.04)
DNR11-FBP.120
PDA11-FBP.050
Extension cable
Designation Cable length Type Order code Pkg Weight
2CDC341007F0004
qty (1 pce)
kg (lb)
Extension cable (female/male), shielded 0.3 m CDP15-FBP.030 1SAJ929140R0003 1 0.01 (0.02)
Extension cable (female/male), shielded 0.6 m CDP15-FBP.060 1SAJ929140R0006 1 0.01 (0.02)
PDA12-FBP.050 Extension cable (female/male), shielded 1.5 m CDP15-FBP.150 1SAJ929140R0015 1 0.20 (0.44)
Extension cable (male/open), shielded 1.5 m CDP16-FBP.150 1SAJ929150R0015 1 0.20 (0.44)
www.abbcontrol.fr/softstarter
Coordination tables
Online tool for coordination with short circuit protection,
overload protection and line contactor.
applications.it.abb.com/SOC
SOC
-
Coord Selected O
in ptimiz
Coord ation ed
in
motor ation table
protec s for
tion
new.abb.com/low-voltage/products/softstarters http://new.abb.com/low-voltage/launches/pstx
new.abb.com/low-voltage/
products/softstarters
ABB AB Note
Catalog 1SFC132012C0201 - Rev. B, November 2016. Prod. ABB AB, Low Voltage Products
We reserve the right to make technical changes or
Low Voltage Products modify the contents of this document without prior
SE-721 61 VSTERS, Sweden notice. With regard to purchase orders, the agreed
particulars shall prevail. ABB does not accept any
new.abb.com/low-voltage responsibility whatsoever for potential errors or
possible lack of information in this document.
new.abb.com/low-voltage/launches/pstx
We reserve all rights in this document and in the
subject matter and illustrations contained therein. Any
reproduction, disclosure to third parties or utilization of
its contents - in whole or in parts is forbidden without
prior written consent of ABB.