Sei sulla pagina 1di 20

O V A L P R O D U C T G U I D E

Flowmeter Product Name

Ultrasonic Electromagnetic
High accuracy, general versatility and positive displacement flowmeter p.3
"ULTRA OVAL"
Batch controller furnished Inexpensive general-purpose electromagnetic flowmeter p.10
Auto temperature compensator equipped "MAG-OVAL II"
Inexpensive explosionproof positive displacement flowmeter p.3
"ECO OVAL"
Positive Displacement

Inexpensive positive displacement flowmeter for supplying boiler with p.4 Ultrasonic flowmeter for gas service p.11
oil and water "FLOWPET-EG" "Psonic-1"
Super fine, extremely small size positive displacement flowmeter p.4
"Super Micro Flowmate" Inexpensive Mass Flow Monitor for Energy Saving Control p.11

Thermal
Micro flow, small size positive displacement flowmeter p.4 "Mass Flow Monitor"
"Flowmate" Inexpensive Mass Flow Monitor for Measuring City Gas (13A) p.11
Zero differential pressure, high response positive displacement flowmeter p.5 "High Accuracy Mass Flow Monitor"
"Hi SHOT SERVO 1" High Accuracy in wide viscosity range turbine flowmeter p.12

Turbine
Positive displacement flowmeter for gas measurement p.5 "EX Turbine"
"GAS OVAL" Turbine Flowmeter for Saturated Steam p.12
Low vibration, no pulsation and low noise positive displacement flowmeter p.5 "Turbo Steam Meter"
"ULTRA UF-II"
"Valve Position Indicator" p.12

Other
High performance high accuracy Coriolis flowmeter p.6
"ALTI mass TypeU"
"SV Meter" p.12
Straight tube Coriolis flowmeter p.7

Related Instruments
"ALTI mass TypeS"
"Strainer" p.13
Coriolis

General-purpose Coriolis flowmeter p.7


"ALTI mass TypeB"
"Air Eliminator" p.13
95MPa Super High-pressure Coriolis flowmeter p.7
"CN004H"
"Flow Straightener and Honey Vane S" p.13
Inexpensive microflow type Coriolis flowmeter p.7
"CoriMate"
High performance standard type vortex flowmeter p.8
"Smart type EX DELTA"
Cryogenic vortex flowmeter p.8
"Cryogenic EX DELTA"
Wide flow range high accuracy vortex flowmeter p.8
"Insertion type EX DELTA"
Thermistor type (standard) vortex flowmeter p.8
"VF Series"
Pressure correction function furnished high accuracy, low cost vortex flowmeter p.9
Vortex

"DELTA FLOWPET-DX"
High performance low cost type vortex flowmeter p.9
"DELTA FLOWPET"
Vortex flowmeter with built-in temperature/pressure sensor p.9
"Hybrid Multi DELTA"
Resin-molded inexpensive vortex flow monitor p.10
"Eggs DELTA"
Resin-molded inexpensive vortex flow monitor dedicated to pulse output p.10
"Eggs DELTA Pulse"
Ultrasonic Vortex Flowmeter with All Teflon made Wetted Parts p.10
"ULTRA Egg"

Electronic Instrument Product Name


"Totalizer" p.14

"Batch Counter" p.14


Electronic Instruments

"SU Series" p.15

"Flow and Density Computer" p.16

"Converter and Compensator" p.18

"Steam Flow Computer" p.18

"Smart Communication Unit" p.19

"Pulse Checker" p.19

2 OVAL PRODUCTS GUIDE


ULTRA OVAL
High accuracy, general versatil- Specifications
Item Description
ity and positive displacement Standard, High temperature service,
Type
flowmeter Low temperature service
Nominal size 10, 20, 25, 40, 50mm
High accuracy: 0.5% RD (Option: 0.2% RD) Connection standard JIS10, 16, 20, 30K/ASME or JPI 150, 300 flange
Since the metering chamber is a pocketless Wetted area SCS14, other
Material
configuration, a wide range of fluids including Case SUS316, other
chemical fluid are acceptable. Flow range 0.2 L/h to 44 m3/h (9 types) 1
Battery-operated model is also available Accuracy 0.5% RD (Option: 0.2% RD)
(battery replaceable). Operating temp. range -10 to +120 (Standard type) 2
Max. operating pressure 2.94MPa
Low pressure loss and high durability
Configuration Flameproof or intrinsic safety
1: Viscosity 5 to 1000 mPas
2: Max. 260 for high temperature,
Min. -60 for low temperature
Applicable to max. 1000m3/h (350 mm)

Batch controller furnished Specifications


Item Description
A field type ULTRA OVAL flowmeter equipped ULTRA OVAL 39 to 65 type,
Flowmeters
with a batch controller furnished counter. When ULTRA UF-II 80 to 88 types
used in conjunction with a all pneumatic Display 6-digit LCD
Operation Start, stop, reset with front button
automatic valve (ball valve, diaphragm valve),
Batch setting:
you can readily build a high performance batch Initially controlled flow (counts) For 2-step
system. The counter operates on a built-in Controlled flow timing before ON/OFF
Functions Setup
target set point (counts) controlling
battery and has lightweight compact construc- Missing pulse detection,
tion. In accordance with the purpose of applica- overshoot (counts)

Positive Displacement
tion, you can choose LW74E that opens and Repeat process, backup in EEPROM
Other
(Cumulative total count, batch set point, parameters)
closes the valve in a single step, or, for more Water-proof (IP65)
Configuration
precise batch process, LW76E that opens and Non-explosionproof or intrinsic safety
closes the valve in two steps. Both types have
intrinsic safety and explosionproof construction.

Auto temperature compensator Specifications


Item Description
equipped ULTRA OVAL 39 to 65 types,
Flowmeters
Ultra register finds extensive use in the transactions ULTRA UF-II 80 to 88 types
Platinum temperature measuring
of petroleum products, or elsewhere where flow Temp. input resistance (Pt 100)
measurement under given reference temperature is Temp. range for
correction -10 to +150
required. It converts the flow information of
Display 8-digit LCD
process materials at the process temperature to
2 outputs selectable from various
that at the reference temperature. Can mount on Output
pulse/analog signals
ULTRA OVAL (39 to 65 types) and ULTRA UF-II (80 Calculation
Based on JIS K 2249 or JIS K 2240,
and 3 correction
to 88 types) flowmeters.
Conversion Accuracy 0.1% or better

ECO OVAL
Inexpensive explosionproof Specifications
Item Description
positive displacement flowmeter Type For oils, water, chemical liquids
High accuracy: 0.5% RD Nominal size 8, 10, 20, 25, 40, 50 mm (depends on model)
(oils, chemical liquids) 1.0% RD (water) Connection standard JIS 10K or screw-mount
FC250 (for oils), SCS13 or equivalent
Patternapproved meter for stationary oil Wetted area
(chemical liquid for water)
measurement Material
Special resin (for oils and water),
Rotor SUS316L sintered (chemical liquid)
Applicable to various kinds of liquids
For oil: 5 to 24000 L/h (for 5 to 200 mPas)
Battery-operated model is also available Flow range For water: 200 to 12000 L/h
(battery replaceable). Chemical liquids: 4 to 20000 L/h (0.8 to 2 mPas)
Accuracy 0.5% RD (oils, chemical liquids), 1% RD (water)
Operating temp. range 0 to 120 (explosionproof: 0 to 100)
Max. operating pressure 1.96 MPa or 1.18 MPa (depends on type)
Configuration Flameproof or intrinsic safety
: 0 to 80 for water

OVAL PRODUCTS GUIDE 3


FLOWPET-EG
Inexpensive positive displace- Specifications
Item Description
ment flowmeter for supplying Type For oils For water
boiler with oil and water Nominal size 20, 25, 40, 50mm
High accuracy: 0.5% RD (oils) Connection standard JIS10K
1.0% RD (water) Body FC250 Stainless
Material
Rotor Special resin
High durability
Flow range 7 to 24000L/h 200 to 12000L/h
Display orientation is adjustable vertically in the Accuracy 0.5%RD 1.0%RD
range of 180 . Operating temp. range 0 to 120 0 to 80
Battery-operated model is also available Max. operating pressure 1.18MPa
(battery replaceable). : Viscosity 2 to 5 mPas
: High temperature of max. 150 is available for oils.

Super Micro Flowmate


Super fine, extremely small size Specifications
Item Description
positive displacement flowmeter Model Type 38 Type 39
(Worlds smallest and low cost) Connection standard R1/4 Rc1/4
A flowmeter best suited for monitoring extremely Body PEEK resin SUS316
Material
fine flow rate in the process of domestic-use fuel Rotor PEEK resin PPS resin
battery, and fine ceramic firing, experiment, and Flow range 0.09 to 3 L/h 0.12 to 6 L/h
adding process. Accuracy 3 to 10%RD 3 to 8%RD
Operating temp. range -10 to +60 -20 to +80
Monitoring microflow of 1.5 mL/min or more Max. operating pressure 0.3MPa 0.49MPa
is available (type 38).
Positive Displacement

Built-in pulse generator


Sturdy and low cost

Flowmate
Micro flow, small size positive Specifications
Item Description
displacement flowmeter Model Type 40 Type 41 Type 45
A flowmeter best suited for measuring very small Connection standard Rp1/8 Rp1/4
flow rates of various liquids in addition to the Body SUS316 or Aluminum + Alumite finished
Material
application as a fuel consumption meter for Rotor Special resin Special resin or SUS316L sintered
combustion chamber and heating equipment. Flow range 1 to 50L/h 2 to 100L/h 7 to 500L/h
Accuracy 1.0%RD
Built-in pulse generator
Operating temp. range -20 to +80
Sturdy and low cost Max. operating pressure 0.98MPa
: Viscosity 0.8 to 2 mPas

4 OVAL PRODUCTS GUIDE


Hi SHOT SERVO 1
Wide range Zero differential pressure, high Specifications
Item Description
response positive displacement Applicable fluids Light oil, gasoline
flowmeter Flow range 0.1 to 30 L/h, 0.2 to 60 L/h
By the use of servomechanism to set the differen- Reproducibility 0.02% (under temp. variation within 1)
Repeatability 2 = 0.04% (at 1/2 of full scale flow rate)
tial pressure across the flow inlet and flow outlet
Accumulated Open collector Max. 50 kHz
to zero through high accuracy gears, you can flow rate
Output
measure the flow rate with high accuracy. Temperature 4 to 20 mADC (0 to 100)
Abnormality Contact
Best suited for measuring injection quantity
Operating temp. range -10 to +80 (standard)
and amount of additives.
Max. operating pressure 1 MPa
Non-explosionproof or TIIS flameproof
Configuration
(Exd II BT4)

GAS OVAL
Positive displacement flowmeter Specifications
Item Description
for gas measurement Nominal size 15, 20, 25, 40mm
A high accuracy gas measuring flowmeter having Connection standard JIS 10K
the same structure as the OVAL flowmeter that Body Aluminum (alumite finished)
Material
(Non-explosionproof) has been established in both accuracy and Rotor Special resin
Flow range 180 (75) L/h to 20 m3/h (5 types)
experience as a flowmeter for measuring general
Accuracy 1.0% RD, other
liquids. Operating temp. range -10 to +60

Positive Displacement
Best suited for measuring general gas including Max. operating pressure 0.97MPa
air, carbon dioxide gas, and nitrogen gas. Configuration
Non-explosionproof or flameproof,
intrinsic safety
Battery-operated model is also available
(battery replaceable).
(Explosionproof)

ULTRA UF-
Low vibration, no pulsation and Specifications
Item Description
low noise positive displacement Nominal size 80, 100mm 150 to 450mm
flowmeter Connection standard JIS 10K/ASME125, 150 JIS 10, 20K/ASME150
Constant speed rotation, constant flow rate, Body FC250, SCPH2 SCPH2
Material
Rotor FC250
pulsation-free, and constant torque contribute to
Flow range 12 to 2300(2800) m3/h (9 types)
the operation with small pressure loss, extremely Accuracy 0.2% RD 0.5% RD or 0.2% RD
quiet and low oscillation. Operating temp. range -5 to +120
Small sizes for higher flowrates Max. operating pressure 0.98MPa, 1.37MPa 1.96MPa
Configuration Flameproof or intrinsic safety
High durability
: Light oil
Battery-operated model is also available
(battery replaceable).

OVAL PRODUCTS GUIDE 5


ALTI mass TypeU
High performance high accuracy Specifications
Item Description
Coriolis flowmeter Nominal size 10, 15, 25, 40, 50, 80, 100, 150mm
Wide range of lineups from ultra-micro to large Connection standard JIS10, 20, 30, 40, 63K RF
bore flowmeters ASME or JPI 150, 300, 600/Ferrule/screw mount
Wetted parts material SUS316L, Alloy C
Highaccuracy: Flow range 0 to 372000kg/h(12 types)
0.1% RD Zero stability error of reading (liquid) Liquid 0.1% RD Zero stability error of reading
0.5% RD Zero stability error of reading (gas) Accuracy Gas 0.5% RD Zero stability error of reading
Density 0.0005g/mL (Varies with type)
Intelligent self-diagnosis function Operating temp. range Single unit type: -20 to +90
Field adjustable setting 1 Separate type: -200 to +200
9.4MPa(Depends on process connection) 2
High speed response: 10 times or better than Max. operating pressure
13.56MPa(CA100, CA150)
conventional transmitter Configuration Flameproof + Intrinsic safety
Ease of maintenance 1: In case of explosionproof type, explosionproof temp.
class is applied.
Density measurement is available 2: High-pressure type (43 MPa at normal temp.) is available in
(option for liquids) some models.
Compliance with High Pressure Gas Safety Law
(some type excluded)

High performance large bore


Coriolis flowmeter
High accuracy: 0.1% RD Zero stability error
of reading
Density measurement is available
(option for liquids).
Compliance with High Pressure Gas Safety Law
Coriolis

High performance super micro Specifications


Item Description
type Model CA00A CA001
Mass measurement from 0.4 (0.2) g/min is Nominal size 1/4
available (CA00A). Connection standard R 1/4
Wetted parts SUS316L
Direct piping is available without requiring Material
Case SUS304
vibration-proof base. Flow range 0.4(0.2) to 60g/min 1.5 to 225g/min
Accuracy 0.2% RD Zero stability error of reading(liquid)
Operating temp. range -200 to +200
Max. operating pressure Liquid:15MPa at 20, Gas:0.98MPa
Configuration Flameproof + Intrinsic safety
: In case of explosionproof type, explosionproof temp.
class is applied.

6 OVAL PRODUCTS GUIDE


ALTI mass TypeS
Straight tube Coriolis flowmeter Specifications
Item Description
High accuracy: 0.2% RD Zero stability error
Nominal size 15, 25, 40, 50, 80mm
of reading
Connection standard JIS 10, 20K/ASME or JPI 150/Ferrule
Sensor is completely welded to a single straight Wetted parts material SUS316, other
tube. Flow range 0 to 108000 kg/h (6 types)
Excellent detergency without stagnation of liquid Accuracy 0.2% RD Zero stability error of reading
Intelligent self-diagnosis function
Single unit type: -25 to +90
Operating temp. range
Separate type: -40 to +130
Field adjustable setting Max. operating pressure 2.45MPa (Depends on process connection)
High speed response: 10 times or better than Configuration Flameproof + Intrinsic safety
conventional transmitter : In case of explosionproof type, explosionproof temp.
class is applied.
Ease of maintenance

Density measurement is available


(option for liquids).
Compliance with High Pressure Gas Safety Law
(some type excluded)

ALTI mass TypeB


General-purpose Coriolis flow- Specifications
Item Description
meter Nominal size 10, 15, 25, 40, 50mm
High accuracy: 0.2% RD Zero stability Connection standard JIS 10, 20, 30K/ASME or JPI 150, 300/Ferrule
error of reading Wetted parts material SUS316L
Excellent
Flow range 0 to 96000 kg/h (6 types)
detergency without stagnation of
Accuracy 0.2% RD Zero stability error of reading
liquid
Single unit type: -25 to +90
Operating temp. range
Intelligent self-diagnosis function Separate type: -40 to +125
Max. operating pressure 7.9MPa (Depends on process connection)
Field adjustable setting
Configuration Flameproof + Intrinsic safety
High speed response: 10 times or better than : In case of explosionproof type, explosionproof temp.

Coriolis
conventional transmitter class is applied.
Ease of maintenance

95MPa Super High-pressure Coriolis flowmeter (MODEL: CN004H)


For the implementation of FCV Specifications
Item Description
super high-pressure hydrogen Nominal size 3/8
dispenser Connection standard
High pressure corn & thread connection
(male screw 3/4 to 16 UNF)
Pure made in Japan product based on OVALs
Wetted Alloy C (CN004H-HY-900R)
unique technology for implementing FCV super Material parts SUS310S (CN004H-SS-900R)
high pressure hydrogen dispenser. This is a Case SUS304
super high-pressure Coriolis flowmeter to Flow range 0.04 to 4kg/min.
contribute to hydrogen energy society. Accuracy 1% RD Zero stability error of reading
The single flowmeter can cover broad flow Separate type: -40 to +130
Operating temp. range
range while serving to fill fuel tanks of small (Explosionproof: -20 to +120)
95MPa (93 max.) (CN004H-HY-900R)
cars to large buses. (Measurable range:1:100) Max. operating pressure
82MPa (40 max.) (CN004H-SS-900R)
Compliance with High Pressure Gas Safety Law Configuration Intrinsic safety

CoriMate
Inexpensive microflow type Specifications
Item Description
Coriolis flowmeter Type CR002 CR003 CR004
3 types with small bore of 3 mm max. in Nominal size 0.7mm 1.5mm 3mm
nominal size. Connection standard Rc 1/8
Wetted parts SUS316L
Single case construction with built-in probe Material
Case ADC12(Base SUS304)
and transmitter (with display).
Flow range 2.5 to 75g/min 10 to 300g/min 90 to 2700g/min
Single tube structure Accuracy 0.4% RD Zero stability error of reading
Vibration-proof
Operating temp. range -10 to +60
base not required.
Max. operating pressure 2MPa
Configuration Non-explosionproof

OVAL PRODUCTS GUIDE 7


Smart type EX DELTA
High performance standard Specifications
Item Description
type vortex flowmeter Nominal size Wafer:10 to 150mm, Flange:15 to 300mm
Replaceable type model that allows online Connection standard JIS 10, 16, 20, 30K/ASME or JPI 150, 300
inspection and replacement of sensor. Wetted parts material SCS14A or SUS316
Liquid 0.2 to 2510m3/h (water)
Battery-operated model is also available Flow
range Gas 1.8 to 15000m3/h (0.2 MPa air)
(battery replaceable).
Steam 0.013 to 47.6t/h (0.5 MPa saturated steam)
Dia-shaped bluff body applicable to dirty 1.0% RD or 1.0% FS
Accuracy
process (liquid only) is also available. (Nominal size 10 mm is 2.0% FS.)
Operating temp. range -30 to +300 (Max. 460 for high temperature)
Max. operating pressure 5MPa (Depends on process connection rating)
Configuration Flameproof or Intrinsic safety

Cryogenic EX DELTA
Cryogenic vortex flowmeter Specifications
Item Description
Measurement of cryogenic fluids including Nominal size Wafer:10 to 150mm, Flange:15 to 300mm
liquid nitrogen, oxygen, and argon is possible. Connection standard JIS 10, 16, 20, 30K/ASME or JPI 150, 300
Endothermic fin is provided at the mounting Wetted parts material SUS316
tube. Flow Liquid 0.2 to 2510m3/h
range Gas 2 to 15000m3/h
1.0% RD or 1.0% FS
Accuracy
(Nominal size 10 mm is 2.0% FS.)
Operating temp. range -196 to +300
Max. operating pressure 5MPa (Depends on process connection rating)
Vortex

Insertion type EX DELTA


Wide flow range high accuracy Specifications
Item Description
vortex flowmeter Mounting system Fixed Hot tap
Measurement of liquid, gas and steam is 200, 250, 300, 400, 400, 500, 600, 800,
Nominal size of 500, 600, 800, 1000, 1000, 1500,
possible. acceptable pipeline
1500, 2000mm 2000mm
There are two mounting types: fixed type and Probe nominal size 50mm
hot tap type (maintenance is possible without Connection standard JIS 10K/ASME 150/JPI 150
stopping flow). Major Body SUS304
material Bluff
Battery operated model requiring no external body SUS304
power supply is also available Air (atmospheric pressure): 12 to 50 m/s,
Flow range Water: 0.6 to 6 m/s
(battery replaceable).
Accuracy 2% FS
Operating temp. range -30 to +300
Max. operating pressure Depends on flange rating.

VF Series
Thermistor type (standard) Specifications
Item Description
vortex flowmeter Nominal size Wafer:20 to 150mm, Flange:200 to 500mm
Sensor has a replaceable construction. Connection standard JIS 10, 20, 30K/ASME 150, 300
Maintenance and inspection is possible without Wetted parts material SUS304, other
stopping fluid. Flow range 2.87 to 19000m3/h (0.2 MPa air)
Accuracy 1.0% RD or 1.0% FS
Besides standard type, gas purge type
Operating temp. range -30 to +130 (for SUS304)
applicable to gas including dust mist and
Max. operating pressure 5 MPa, 1.89 MPa for 400 mm or bigger
high/low temperature gas and insertion type
Configuration Combination of intrinsic safety and flameproof
applicable to big bore (200 to 2000 mm) are
also available.

8 OVAL PRODUCTS GUIDE


DELTA FLOWPET-DX
Pressure correction function Specifications
Item Description
furnished high accuracy, low cost Nominal size 15, 25, 40, 50, 80, 100, 150mm
vortex flowmeter Connection Wafer type
Built-in pressure sensor (for steam and gas) Connection standard JIS 10, 16, 20, 30K/ASME or JPI 150, 300
Wetted parts material SCS14A or SUS316, other
Max. operating temperature is 200. Flow range 12.4 to 8820kg/h (0.5 MPa saturated steam)
Low pressure loss Accuracy 2.0% RD (at 0.25 MPa or more)
Operating temp. range Max. 200
High accuracy and low cost type Max. operating pressure 1.0MPa
: Model without pressure correction is also available
for steam, gas, liquid)

DELTA FLOWPET
High performance low cost type Specifications
Item Description
vortex flowmeter Nominal size Wafer type :10, 15, 25, 40, 50, 80, 100mm
Measurement of max. 200 steam is available. Connection standard JIS 10, 16, 20, 30K/ASME or JPI 150, 300
Wetted parts material SCS14A or SUS316, other
Battery-operated model is also available
Liquid 0.2 to 205m3/h (water)
(battery replaceable). Flow
Gas 1.8 to 1280m3/h (0.2 MPa air)
range
Equipped with flow switch function Steam 0.013 to 4t/h (0.5 MPa saturated steam)
Supporting Accuracy 1.0% FS (2.0% FS for only 10 mm)
quick delivery
Operating temp. range -10 to +80 (Max. 200 for high temperature)
Max. operating pressure 4.51MPa (Depends on process connection rating)

Vortex
Hybrid Multi DELTA
Vortex flowmeter with built-in Specifications
Item Description
temperature/pressure sensor Applicable fluids Compressed air, nitrogen
Hybrid flow sensor configured by a combination Nominal size 25, 40, 50, 65, 80, 100, 150mm
of a vortex flowmeter and thermal mass Connection standard 50 mm max.: Rc internal thread
flowmeter to cover wide flow range from 65 mm min.: JIS 10K/ASME150 flange
50 mm max.: aluminum,
extremely low flow to high flow rates in utility Body material
65 mm min.: stainless
gas measurement. Flow range 0.6 to 13440Nm3/h at 0.6MPa
Multi flowmeter capable of outputting volume Accuracy 5% RD 0.05% of max. flowrate
flowrate, mass flowrate, temperature, and Operating temp. range 0 to 50
pressure with built-in temperature and pressure Max. operating pressure 0.78MPa
sensors.
Integral screw-mount type

Integral flange type Integral flange type (150 mm) Insertion type

OVAL PRODUCTS GUIDE 9


Eggs DELTA
Resin-molded inexpensive vortex Specifications
Item Description
flow monitor Type Standard Metal joint High temp.
Usable as a flow monitor for utility and various Nominal size 4, 8, 15, 25mm 8, 15mm
kinds of experiments. Connection standard R screw, other Rc screw Rc screw
Wetted parts material PPS resin PPS + stainless Stainless
You can monitor instantaneous flowrate
Flow Liquid 0.4 to 133L/min 2 to 45L/min
(/min. and /h) and total flow (L) through range Gas 7.2 to 850L/min
digital display.
Accuracy 3% FS
4 to 20 mA output or pulse output are Operating temp. range -10 to +80 -10 to +150
selectable. Max. operating pressure 0.98MPa
Flow switch function is provided. (option)
Battery-operated model is also available
( battery replaceable).

Eggs DELTA Pulse


Resin-molded inexpensive vortex Specifications
Item Description
flow monitor dedicated to pulse Type Standard Metal joint High temp.
output Nominal size 4, 8, 15, 25mm 8, 15mm
Vortex

Small size, light weight, lowest price vortex flow Connection standard R screw, other Rc screw Rc screw
monitor Wetted parts material PPS resin PPS + stainless Stainless
Flow Liquid 0.4 to 133L/min 2 to 45L/min
Construction durable against dust and mist. range Gas 7.2 to 850L/min
Maintenance free Accuracy 3% FS
Operating temp. range -10 to +80 -10 to +150
Liquid and gas measurable. Max. operating pressure 0.98MPa
: Explosionproof type combined with barrier is also available
(ATEX, TIIS)

ULTRA Egg
Ultrasonic Vortex Flowmeter with Specifications
Item Description
All Teflon made Wetted Parts Nominal size 15mm
By the employment of high corrosion resistant Connection standard Final lock joint or tube connection
material, the ULTRA Egg is best suited for measur- Wetted parts material NEW PFA
ing the flowrate of ultra-pure water, chemicals, Flow range (water) 8 to 70L/min 3 to 70L/min
and fluids sensitive to chemical action or easy-to- Accuracy 3% RD 3% FS.
change liquid. Operating temp. range -20 to +100
Absence of moving parts and a pocketless Max. operating pressure 0.7MPa at 25
configuration : 1% RD or 1% FS (Option)

Unsusceptible to mechanical noise such as


tubing vibration
Wide flow range and high accuracy

MAG-OVAL
Inexpensive general-purpose Specifications
Item Description
Electromagnetic

electromagnetic flowmeter Nominal size 3 to 15mm 25 to 150mm


Wide flow range and measurable from lower Connection Screw type Wafer type
flow rates Lining Teflon PFA Teflon PTFE
Material
Electrode SUS316L, Alloy C276, tantalum, platinum
High speed pulse output of max. 1 kHz
Flow speed range Max.10m/s
Nearly zero pressure loss Flow range Max.6.3m3/h Max.640m3/h
Two-line display allows concurrent monitoring Accuracy 0.5%RD to (Depends on bore and flow speed.)
of total flowrate and % instantaneous flow Min. conductivity 10S/cm
Operating temp. range -10 to +130
Max. operating pressure 2.94MPa
Configuration Non-explosionproof

10 OVAL PRODUCTS GUIDE


Psonic-1
Ultrasonic flowmeter for gas Specifications
Item Description
service Nominal size 50, 80, 100, 150, 200, 250, 300mm
Highly accurate measurement is possible in Connection JIS10, 20, 30K/JPI150, 300

Ultrasonic
wide flow range from small flow area. Body SUS304TP
Material
Flange SUSF304 or SF440A (200mm or bigger)
Measurement of forward and reverse flows is
Flow range -30 to +30m/s
possible.
Accuracy 1%RD 0.03%FS
Durable configuration with no moving part Operating temp. range -30 to +80 (non-explosionproof)
requiring little maintenance. Max. operating pressure 1.96MPa (Depends on flange rating)
Transmitter: Pressure resistant explosionproof,
Nearly zero pressure loss Configuration
Sensor: Special explosionproof
: 350 to 600 mm are also available on demand.

Mass Flow Monitor


Inexpensive Mass Flow Monitor Specifications
Item Description
for Energy Saving Control Nominal size 15, 20, 25, 40, 50mm
1:60 wide flow range Connection Rc female screw
Flow range 10 to 600L/min (normal)/
Simple and durable sensor with no moving part 135 to 8000L/min (normal) (5 types)
while protected by sheath pipe Operating temp. range 0 to 50
Neither temperature nor pressure compensation Pressure range 0 to 0.7MPa
required 2%FS (Lower than 40% of FS)
Accuracy
5%RD (More than 40% of FS)
Applicable fluids Compressed air, nitrogen

High Accuracy Mass Flow Monitor


Inexpensive Mass Flow Monitor Specifications
Item Description
for Measuring City Gas (13A) Nominal size 25, 40, 50mm

Thermal
Gas flow rate can be measured exactly on mass Connection Rc female screw or JIS 10K flange
base. Flow range 40 to 600L/min (normal)/
167 to 2500L/min (normal)
Simple and durable sensor with no moving part Operating temp. range 0 to 60
while protected by sheath pipe Pressure range 0 to 0.7MPa (0.98MPa possible)
Suited for measuring the city gas use in the Accuracy 1%FS
furnace, boiler, and air-conditioning equipment Applicable fluids City gas (13A), air, nitrogen

OVAL PRODUCTS GUIDE 11


EX Turbine
High Accuracy in wide viscosity Specifications
Item Description
range turbine flowmeter Type Standard, Low viscosity Standard, High viscosity
Stable and highly accurate flow measurement Nominal size 15 to 50mm 80 to 400mm
is possible for liquids in wide viscosity range Connection standard JIS10, 16, 20, 30K/ASME or JPI150, 300
including low Reynolds number regions. Body material SUS304, other
Flow range 0.63 to 54m3/h 15 to 4500m3/h
High accuracy: 0.2%RD (Standard) (Standard)
Accuracy 0.2%RD or 0.5%RD
13 nominal size lineups from 15 mm to 400 mm
Operating temp. range -30 to +120 (Non-explosionproof)
Max. operating pressure Depends on connection standard rating.
: Models for High temperature of max. 350 and low temperature
of min. -196 are also available.
Turbine

Turbo Steam Meter


Turbine Flowmeter for Saturated Specifications
Item Description
Steam Type Mini Type Standard Type
Simple and sturdy construction and ease of Nominal size 25mm 50, 80, 100mm
handling Connection standard JIS10K
Flow range
Both manual pressure adjustment and auto 15 to 200kg/h 79 to 8751kg/h
(0.49 Mpa steam)
adjustment types are available. Accuracy 2%RD
Total flow rate can be displayed directly in kg. Operating temp. range Max. 220
Remote accumulation is also possible. Max. operating pressure 0.98MPa
: Differs with selected nozzle or orifice plate besides nominal size.

Valve Position Indicator


Connected in series with the hydraulic circuit of Specifications
a hydraulic drive system, the valve position Item Description
Nominal size Rc3/8 to Rc3/4
6 to 20
indicator shows the operating position of a
Body material Standard type: FC250, High-pressure type: FCD450
cylinder exactly by measuring the quantity of oil Flow range 5 to 480L/h150 to 6000L/h
delivered. As a highly accurate sturdy sensor Indicated accuracy +3% (accuracy as flowmeter 0.3%RD)
having the structure of OVAL flowmeter, this is Operating temp. range -10 to +80
used for remotely monitoring central control of Max. operating 13.73Mpa
pressure 20.58Mpa (High pressure type)
multiple hydraulic loading valves used in oil
Indicated accuracy 0 to +3%
tankers. Other Microswitch and/or potentiometer can be installed.
Application Detection of operating position for hydraulic
cylinder with a capacity of 0.05 to 140 L
Other

SV Meter
Critical nozzles are devices that can be used for Specifications
flowmetering, making use of gas flow in the Item Description
Applicable fluids Air
sonic velocity region (critical flow) and are
Expansion uncertainty U=0.32%k=2
characterized by a high degree of accuracy and Sound velocity range 0.5 max. (downstream press/upstream press)
repeatability. Because of their excellent repeat- Material SUS304
ability, critical nozzles are accepted as national Temperature 10 to 35
Operating
standards in calibrating gas flowmeters. In range Pressure 50 kPa (abs) min.
addition, they are used frequently in the Relative 0 to 70%
humidity
performance test of various kinds of gas flow
control equipment, making use of the charac-
teristics of generating steady flow.

12 OVAL PRODUCTS GUIDE


Strainer
Strainer is a device that is installed at the inlet Specifications
Medium size side of a flowmeter. It protects the flowmeter by Description
Item
Small size Medium size Large size
capturing foreign solids suspended in the fluid
Nominal size 10 to 20mm 25 to 200mm 150 to 400mm
being metered. It is usually necessary to provide Connection standard JIS10, 20, 30K, JPI/ASME150, 300
a strainer for a flowmeter with moving parts Body SCS14A SCS14A/FC250 SS400
Material
(OVAL flowmeter, UF-II flowmeter, some turbine Net SUS316 SUS304/SUS316 SUS304
flowmeters). Net mesh
200 25 to 100 25 to 30
(Depends on bore rating)
Max. operating
1.18MPa 0.98MPa 1.18MPa
pressure at JIS 10K

Large size, steel plate housing

Small size

Air Eliminator
Air eliminator is a device that is used in the Specifications
loading, unloading, or other similar process of Description
Item
For loading service For unloading service
petroleum oils, etc. It mainly eliminates the gas
Nominal size 50 to 500mm 100 to 500mm
entrained in the liquid being metered immedi- Connection standard JIS10K, JPI /ASME150
ately after the start or before the end of liquid Body SS400
flow and discharges the gas outside the pipeline. Float SUS304
It is installed at the inlet of a flowmeter to Material Outlet valve SCS13, SUS304
ensure the condition for exact flow rate Outlet
Viton
valve base
measurement. Max. operating Pressure 0.97MPa
Max. operating temp. 80

Related Instruments
Standard Second Class pressure vessel certified product

For loading/unloading service

Flow Straightener and Honey Vane S


Located upstream of the vortex or turbine Specifications
flowmeter, a flow straightener or Honey Vane S Description
Item
Flow Straightener Honey Vane S (Wafer type)
serves to stabilize disturbances in the flow
Nominal size 20 to 600mm 25 to 300mm
velocity pattern into a uniform flow distribution, Connection standard JIS10, 20, 30K, JPI /ASME150, 300
Flow Straightener
thus providing the right conditions for accurate STPG370, STPY400, SB410,
Body SUS316
flow measurement. It not only eliminates the SUS304TP, SUS316TP
need for extra lengths of straight pipe required Material SS400, SF440A, SFVC2A,
Flange SUS304, SUS316, SUSF304,
for certain piping conditions, but also substan- SUSF316
tially reduces space required. Inner tube SUS304, SUS316
Steel: -10 to +300(Flange: SS400
Applicable fluid temp. Outer tube: In case of STPY400, SB400, 0 to 300)
Stainless steel: -196 to +300

Honey Vane S

OVAL PRODUCTS GUIDE 13


Totalizer
This compactly built LCD counter a Totalizer Specifications
pulse signal from the flowmeter and Item Description
Model EL0122 EL0123
displays both the totalized flow and Contact pulse, voltage pulse, current pulse,
signal
instantaneous flowrate digitally. open collector pulse
200 Hz (50 Hz with contact input)
Input signal Response Can respond to 2 kHz with 1/10 or 1/100
pulse
frequency division.
Supply to
13.5V or 24V 50mA
pulser
Open collector after
Pulse Open collector
Output optical isolation
MODEL EL0122
signal Analog 4 to 20mADC or 1 to 5VDC
Alarm Open MOS-FET 2
LCD
Display Instantaneous (/h, /min),
total flow (resettable, nonresettable)
Power supply 85 to 264VAC 50/60Hz Battery operated (replaceable)

MODEL EL0123

Batch Counter
When combined with a flowmeter and auto ON/OFF valve, it provides a design flexibility to build a
Electronic Instruments

flow meter capable of measuring given total flow rate (preset flow). With high performance type
batch counter, start, stop and reset can be controlled from counter outside. Standard panel mount
type and explosionproof type are also available.

Batch counter specifications


Item Description
Standard type EL1810 Model Batch counter (EL1810) Explosionproof batch counter (EL7310)
Input signal Contact pulse, Open collector pulse
Voltage pulse, Current pulse

Parameter setting Batch setting, Grand total setup, Initial- and Final -count setup,
Missing pulse setup, Scaler setup, Overmeasurement setup, Frequency division
Valve (Regulation, Upper-limit signal)
Output signal End-of-batch, Remote totalizer pulse
Alarm (Missing pulse, Overmeasurement, Parameter error)
Ambient temperature -10 to +50
Power supply 85 to 264VAC 50/60Hz
Explosionproof type EL7310 Configuration Non-explosionproof Flamproof : Exd II BT4
Installation Panel mount type Wall mount or stanchion type

14 OVAL PRODUCTS GUIDE


SU Series
With a wide choice of power supplies, the F/I and other converters in the form of small, lightweight
plug-ins are available. The series offers convenience in the design of an instrumentation system that
may consist of a flowmeter, sensor, controller, recorder, flow indicator, etc. The series includes, by
function, power supplies, F/I converter, pulse distributor, pulse divider, pulse scaler, and meter
selector.

SU Series Specifications

Electronic Instruments
Batch counter specifications
Item Description

Name and Model Pulse distributor Pulse divider F/I converter Pulse scaler Meter selector
SU1308 SU1304 SU1312 SU1313 SU1352

Input signal Contact pulse, Current pulse, Voltage pulse, Open collector pulse

Input sync pulse output:


Open MOS-FET
Open collector pulse
(3 outputs) 0.2A Flow rate after selection:
Pulse output after scaler correction
Open MOS-FET Pulse width:1ms, 50ms Input sync Open MOS-FET 50mA
Open MOS-FET
Pulse (3 outputs) 0.2A Frequency division: Open collector pulse Valve control:
0.2A (2 circuits)
Pulse width:1ms, 50ms OUT1 1/1 to 1/1000 (20mA) Open MOS-FET
Pulse width:1ms, 50ms
OUT2 1/1 to 1/1000
Output Scaler:0.0001 to 1.9999
signal OUT3 1/10 to 1/10000
Frequency division:1/1 to 1/1000
4 to 20ADC
(Load resistance: 350
Analog or
1 to 5VDC
(Impedance: 250
Response frequency Max.500Hz 2 kHz (500 Hz for output) 2kHz Max.2kHz
Ambient temp. -10 to +50
Power supply 85 to 264VAC 50/60Hz or 20 to 30VDC
Installation Plug-in type

Item Description
Name and Model Power supply unit SU1503
Supply voltage 12VDC 13.5VDC10%
for power
Output generator 24VDC 24.0VDC10%
Max. current 500mA
Ripple 50Vp-p About
Display 7-segment LED 3 digit display
Ambient temp. -10 to +50
Power supply 85 to 264VAC 50/60Hz

OVAL PRODUCTS GUIDE 15


Flow and Density Computer
EL 4001 series, adopting an easy-to-read large LCD counter, is an advanced flow computer
features IC cards to identify the specific model, change parameters, and data logging. It is
characterized by small size and lightweight cabinet, abundant monitoring information, and
external output function. It accepts information from various flowmeters, density meter,
thermometer, and pressure gauge and processes these information into a measure of flow
rate and density at the reference temperature and pressure. Functionally classified, the
series are grouped into two - flow computer and density computers of a total of six models.
Another model, simple-to-use steam computer, which accepts monitored information with
fixed pressure systems, is also available.

EL4101

Flow Computer Specifications


Item Description
Saturated steam flow computer Superheated steam flow computer
Name and Model
EL4101 EL4111
Flowrate Contact pulse, Voltage pulse, Current pulse, Open collector pulse
Input signal Temperature Pt 100 at 0, 3-wire or 4 to 20 mADC or 1 to 5 VDC
Pressure 4 to 20 mADC or 1 to 5 VDC
Total mass flowrate
Open MOS-FET, Pulse width:1ms/50ms
Pulse Total thermal flowrate
Output
signal Input sync Open collector pulse 13.5 VDC
Analog 4 to 20mADC (Max. load resistance: 500) or 1 to 5VDC(Output impedance: 250)
Electronic Instruments

Alarm Open MOS-FET


Type ST display (128x128 dots) with backlight, 8-digit
Display Total flowrate (mass, thermal),
Item
Instantaneous flow pressure, Compensating factors, Specific gravity, Error
Flow rate in terms of weight 0.5% or better for flowrate displayed
Flow rate in terms of calories 0.6% or better for flowrate displayed
Accuracy Pressure 0.1 of SPAN 0.1 of SPAN
Pt100 at 0: 0.3% of SPAN
Temperature
4 to 20mADC or 1 to 5VDC: 0.1% of SPAN

Communication Interface: RS485 multipoint (max. 16 units are connectable.) dedicated protocol
Baud rate: Standard: 4800bps Max.: 9600bps
Ambient temperature -10 to +50
Power supply 85 to 264VAC 50/60Hz or 20 to 30VDC
Installation Panel-mount type

Flow Computer Specifications


Item Description
Name and Model Gas service with temp./ Liquid service with temp. Gas service for mass conversion with temp./ Liquid service for mass conversion with temp.
pressure compensator EL4121 compensator EL4131 pressure compensator EL4201 compensator EL4211
Flowrate Contact pulse, Voltage pulse, Current pulse, Open collector pulse
Input signal Temperature Pt 100 at 0, 3-wire or 4 to 20 mADC or 1 to 10 VDC
Pressure 4 to 20mADC or 1 to 5VDC 4 to 20mADC or 1 to 5VDC
Total flowrate before
correction Open MOS-FET, Pulse width: 1 ms/50 ms
Pulse Total flowrate after
Output correction
signal Input sync Open collector pulse
Analog 4 to 20 mADC (Load resistance: 500) or 1 to 5 VDC (Impedance: 250), Accuracy: Better than 0.1% of full scale):
Alarm Open MOS-FET
Type ST indicator (128x128 dots) with backlight, Digits: 8
Display Before/after compensation: Before/after compensation: Before/after compensation: Before/after compensation:
Item
(Total, Instantaneous),temp., (Total, Instantaneous),temp., (Total, mass) temp., (Total, mass) temp., pressure,
pressure, comp. coefficient, error pressure, comp. coefficient, error pressure, comp. coefficient, error comp. coefficient, density, error
After compensation 0.2% max.
1/2Pmax. to 0.2% max. After 0.2% max. 1/2max to Pmax of reading After 0.2% max.
Flow rate in terms of reading of reading of reading
Pmax. compensation 1/5Pmax to 0.5% max. compensation
of weight
Pmax of reading
Accuracy
Flow rate in terms 1/5Pmax. to 0.5% max.
Pmax. of reading
of calories
Pressure 0.1% of SPAN 0.1% of SPAN
Temperature Pt100 at 0: 0.3% of SPAN 4 to 20mADC or 1 to 5VDC: 0.1% of SPAN
Communication Interface: RS-485, Max. 16 units can be connected, Velocity: 4800 bps (standard)
Ambient temperature -10 to +50
Power supply 85 to 264VAC 50/60Hz or 20 to 30VDC
Installation Panel-mount type

16 OVAL PRODUCTS GUIDE


Density Computer Specifications
Item Description
Density computer for oscillating-spool
Name and Model
densitometer for gas service EL4321
Temp. resistor Pt 100 at 0 3-wire system
Temp. input
Analog 4 to 20 mADC or 1 to 5 VDC
Input signal
Pressure input 4 to 20 mADC or 1 to 5 VDC
Density input Density period signal: Pulse frequency: 162 to 650 s
Density after correction 4 to 20 mADC or 1 to 5 VDC
Output signal
Alarm output Open MOS-FET
Density before and after correction, Density frequency,
Display
Temperature, Pressure, Molecular weight, Specific gravity, Error
Density before correction 0.1 of SPAN 0.006 g/l
Accuracy Pt100 0.3 of SPAN
Temperature
4 to 20 mADC or 1 to 5 VDC 0.1 of SPAN
Interface: RS485 Multipoint (Up to 16 units can be corrected),
Communication
Dedicated protocol, Baud rate: 4800 bps, Max. 9600 bps
Ambient temperature -10 to +50
Power supply 85 to 264 VAC, 50/60 Hz or 20 to 30 VDC
Installation Panel mount type

Density Computer Specifications


Item Description
Name and Model Density computer for mass flowmeter (with sold content
Density computer for mass flowmeter EL4301
flow calculating capacity provided) EL4311
Flowrate Voltage pulse, Open collector pulse
Temp. resistance bulb Pt 100 at 0, 3-wire system
Temp. input
Analog 4 to 20 mADC or 1 to 5 VDC, 10 mV/ or 5 mV/
Input signal
Density input Tube period signal
Totalizing (Mass, Solid content) Open MOS-FET
Pulse

Electronic Instruments
Total input period Open collector pulse
Analog output Density after correction or 4 to 20 mADC or 1 to 5 VDC
Output signal Temperature (%MASS)
Alarm output Open MOS-FET
Density before/after correction, Temperature, Density before/after correction, Temperature, Total (Mass, Solid content),
Display
Density period, %MASS, Error Instantaneous (Mass, Solid content) temp., Density period, Factor, Error
ULTRAmass MK II density before correction 0.001 g/ml (Factory calibration accuracy: option)
ULTRAmass MK II density after correction 0.002 g/ml (1), 0.006 g/ml (2)
Pt100 0.3 of SPAN
Accuracy
Temperature 4 to 20 mADC or 1 to 5 VDC
0.1 of SPAN
10 mV/ or 5 mV/
Total solid content flow 0.2% of reading
Interface: RS485 Multipoint (Up to 16 units can be corrected) Dedicated protocol,
Communication
Baud rate: 4800 bps, Max. 9600 bps
Ambient temperature -10 to +50
Power supply 85 to 264 VAC, 50/60 Hz or 20 to 30 VDC
Installation Panel mount type
1: In case temperature input is 4 to 20 mADC, 1 to 5 VDC
2: In case temperature input is Pt100 at 0, 3-wire system

Temperature Compensation Specifications


Item Description
Name and Model Flow computer with multifunction temperature compensator EL4501
Flow computer for compensating blend oil temperature EL4401
(without comm. interface), EL4511 (with comm. interface)
Flowrate Contact pulse, voltage pulse, current pulse, open collector pulse
Input signal Temperature Pt 100 at 0, 3-wire system 4 to 20mADC or 1 to 5VDC
Blend 4 to 20mADC or 1 to 5VDC
Total flow before correction Open MOS-FET, Pulse width: 1 ms/50 ms
Total flow after correction Open MOS-FET, Pulse width: 1 ms/50 ms
Pulse After viscosity correction Open MOS-FET, Pulse width: 1 ms/50 ms
Output
After viscosity temperature correction Open MOS-FET, Pulse width: 1 ms/50 ms
signal
Input period Open collector pulse 13.5VDC
Analog 4 to 20 mADC (Max. load resistance: 500) or 1 to 5 VDC (Output impedance: 250)
Alarm Open MOS-FET
System Super Twisted Nematic display (128x128 dots) with backlight, 8 digits
Display Total flow (before and after correction), Temperature, Total flow (before correction, after viscosity correction, after viscosity temp. correction),
Item Temperature, Setting (Density, Viscosity), Correction factor, Frequency, Error
Blend, Total error, Conversion factor, Error
Total after correction 0.2% max. of reading
Accuracy Total after temp. correction 0.075% max. of reading
Temperature Pt 100 at 0 0.3% of SPAN 4 to 20 mADC or 1 to 5 VDC 0.1% of SPAN
Communication Interface: RS485 Multipoint (Up to 16 units can be corrected) Dedicated protocol, Baud rate: 4800 bps, Max. 9600 bps
Ambient temperature -10 to +50
Power supply 85 to 264 VAC, 50/60 Hz or 20 to 30 VDC
Installation Panel mount type

OVAL PRODUCTS GUIDE 17


Converter and Compensator

This flow converter/compensator functions as a flow converter which receives the pulse signal from a flowme-
ter and converts the signal to units, divided frequency, and analog signal, and as a compensator which
compensates the signal for the flow under the reference temperature and pressure of a process fluid (steam,
gas, liquid). You can select either function in accordance with your object.
A small, lightweight rack-mount type converter/compensator series

Flow Converter/Compensator
Item Description
Flow converter (EL0841)
Name and Model Steam service temperature/pressure compensator (EL0842)
Gas service temperature/pressure compensator (EL0843)
Liquid service temperature compensator (EL0844)
Flow input Contact closure pulse, Current pulse, Open collector pulse
Temp. input 1 to 5VDC or 4 to 20mADC or 3-wire Pt 100 at 0
Input signal
1 to 5VDC or 4 to 20mADC
Pressure input
(Power supply for pressure transmitter: Max. 24VDC, 30mA provided)
Analog output 1 to 5VDC or 4 to 20mADC
Pulse 1 output Open MOS-FET
Output signal
Pulse 2 output Open MOS-FET
or Alarm output
Temperature/pressure Flow rate in terms of weight: 0.5%,
compensation for steam Flow rate in terms of calories: 0.6% of RD
Computing Temperature/pressure 1/2PMax. to PMax.0.2% of RD
accuracy compensation for gas 1/5PMax. to PMax.0.5% of RD
Temperature/pressure
0.1% of RD
compensation for liquid
Electronic Instruments

Ambient temperature -10 to +50


Power supply 85 to 264VAC, 50/60 Hz or 20 to 30VDC
Installation Panel mount type

Steam Flow Computer

Specifically intended for steam service, this instrument has a built-in processor and accepts signals from a
steam service Delta Flowmeter (EX DELTA).
It performs steam pressure setting, bore setting and individual meter calibration and indicates the total flow
in terms of weight for precise steam flow measurement.

Steam Flow Computer Specifications


Item Description
Name and Model Steam flow computer EL4061
2-wire current pulse, 1: 20mADC min.
Flow rate
Input signal 0: 4mADC max., Velocity: Max. 2500 Hz
Sensor error Detects overcurrent
Pulse Open collector pulse, Pulse width: 1 to 4ms, 40 to 60ms
Output signal Analog 4 to 20mADC, 1 to 5VDC, 0 to 10mVDC,
(Instantaneous) 10 to 50mADC or 0 to 100ADC
Total counter display 7-digit electromagnetic counter (non-resettable)
Pressure Set with front-panel digital switches (0.00 to 1.99 Mpa)
Setting Nominal size Set with hexadecimal rotary switch
Meter error correction Adjustable with a jumper (Max. 7.5% in 0.5% steps)
Steam flow computer EL4061 Frequency division Set with a jumper, For total: 1/10, 1/100, For output: 1/1, 1/10, 1/100
Accuracy 0.3% of reading
Ambient temperature -10 to +50
Power supply 100V, 110V/115V, 200V, 220/230VAC 10% 50/60Hz

18 OVAL PRODUCTS GUIDE


Smart Communication Unit

The Smart Communication Unit is a communication terminal unit that enables the operator to set up, alter,
adjust parameters, or read out variables in the field or remotely through interactive communications when
used in combination with OVAL Smart series flowmeter. Using a Windows PC at hand as the terminal, it
connects to the 4 to 20 mADC signal transmission lines of the flowmeter to show multiple process
windows.

Smart Communication Unit Specifications


Item Description
Name and Model Smart Communication Unit EL2310
Connector USB (A type)
Input/output Bell 202 USB
Interface Operating temp. -5 to +60
Body: 593319mm
Outline dims.
Flexible probe: 250 to 1500mm
Case Plastics (black)
Comm. protocol HARTTM protocol
Comm. terminal resistance Load resistance 250 min.
Reads, sets up, and saves parameters.
Monitors output.
Functions

Electronic Instruments
Adjusts analog output
Checks analog output loop.

Supported OS Windows 2000, Windows XP (Japanese and English versions)

Pulse Checker
This pulse checker is a versatile servicing tool which offers such capabilities as pulse
integration, frequency measurement, and has variable frequency output and batch pulse
output required to ease inspection, adjustment and maintenance of digital industrial
instruments.
Not only output signal check of flowmeters but also nearly all basic inspection and
adjustment of flowmeters, converters, receiving instruments, computing instruments, etc.
manufactured by OVAL can be done by this instrument.

PC2201

OVAL PRODUCT GUIDE 19


The specification as of May., 2011 is stated in this catalog. Specifications and design are subject to change without notice.

1105 0000 1105S (0000)