OTOACOUSTIC EMISSIONS
OTOACOUSTIC EMISSIONS
Powerful Features
Multiple Diagnostic and Screening Configurations
Sharp, intuitive color screen display
Reliable 15 hour battery life
Powerful DPOAE testing with 12 frequencies, up to
12 kHz
Full color reporting and optional, fast thermal printouts
OAE Probe that never requires cleaning
Charging, automatic printing, and data transfer via the
optional Cradle
Convenient testing for patients with PE tubes
Optional data storage of up to 250 tests
Protected data via non-volatile memory
Low cost, disposable ear tips
Export options for Pass/Refer results to OZ eSP and
HiTrack
Accurate Reliable
The 15 hour battery life with 4 hours
Noisy testing environments are an of charge time maximizes test time of
ongoing challenge for screening and the Corti in all situations. The Corti is
clinical facilities. The patented Noise designed for durability, required with
Artifact Rejection Algorithm smartly portable systems used in demanding
assesses the response in variable clinical and screening environments.
background noise, improving test Non-volatile memory ensures data is
result accuracy and saving valuable held in the Corti memory for printing
test time in noisy environments. and data transfer, even if the battery
The AutoStart check and in-the-ear life is depleted.
calibration ensures testing is started in
acceptable conditions, thus improving
test accuracy.
OTOACOUSTIC EMISSIONS
Product Specifications
Measurement Types Probe Printer (Optional) General Standards
Screening and Diagnostic Testing Connector: HDMI Type: Thermal Dot Matrix IEC/EN 60601-1 Medical electrical
DPOAE: 1.5 to 12 kHz, 40 to 70 dB Probe description: Power: 7.4 V lithium ion battery equipment Part 1: General
SPL Integrated microphone and 100-240V, 50/60 Hz requirements for basic safety
TEOAE: 0.7 to 4 kHz, 83 dB pe SPL receivers in probe head Paper width: 2.25 in. (57 mm) and essential performance -
3rd Edition
Calibration data stored on probe Communication: Bluetooth
Handheld Unit IEC/EN 60601-1-2 Medical electrical
Cable length: 40 in. (101.6 cm)
Display: Color OLED display Power equipment Part 1-2: General
Weight: 1.0 oz. (28 gm) requirements for basic safety
User Input: 4-button operation Battery: 3.6 V rechargeable
Microphone Noise: -20 dB SPL @ lithium ion and essential performance
Connecters:
2 kHz (1 Hz bandwidth), -13 dB Collateral standard:
Micro-USB for charging and Battery Life: 15 hours on time
SPL @ 1 kHz (1 Hz bandwidth) Electromagnetic compatibility
communication Charge Time: 4 hours to 100%
Ear tips: Single use disposable ear UL 60601-1 Medical Electrical
HDMI for probe tips Accessories Equipment, Part 1: General
Weight: 6.4 oz. (180 gm) Requirements for Safety
Cradle (Optional) Standard: Hand-held unit, Probe,
Communication to PC: Micro-USB Micro USB charging cable for CSA C22.2 # 601-1-M90 Medical
Languages: English, German, Operation: Provides PC Database
charger, Database software and Electrical Equipment, Part 1:
Spanish, French, Polish, Russian, communication and charging
micro USB connector, Disposable General Requirements for Safety
Italian, Turkish, Portuguese, Data ear tip kit and tubes, User Manual, IEC 60645-6 Electroacoustics -
Chinese Quick Guide, Calibration Certificate Audiometric equipment - Part 6:
Test memory: 250 tests on unit
Power Supply: 5.0V DC, 1.6A Optional: Cradle, Printer, Carry Instruments for the measurement
Patient names: Patient names on
Case, Ear Tips, Replacement of otoacoustic emissions
unit (optional)
Cables, Replacement Probe, and
Database software: Report output
501C-17 Rev. C
Probe Tubes
to PDF, RTF, Image files