Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
GTG_1328SC_SW50_50barge.doc
Shipyards. Barge Has One Westinghouse 251-B11 Simple Cycle Gas Turbine
Generator Set Alone With All Associated Equipments For Simple Cycle Operation.
The Barge Is Single Haul Construction And Designed And Built In Accordance
With American Bureau Of Shipping (ABS) Rules. The Barge Was Built On 1996,
A) Barge Detail
Power Barge:
Length (Overall) 70.0 Meter
Beam (Molded) 14.0 Meter
Depth (At Side) 5.0 Meter
Draft (Estimated) 4.3 Meter
Ratio, 386.0 Lb/Sec Mass Flow, 5425 Rpm Turbine Speed, 957 F Exhaust
Generator
Brush Type:Turbogenerator, Frame:Bdax7-290er, Continuous Rating,
Rating: 65882 Kva, Rpm:3000, Volts:11.5 Kv, 3 Phase, 50 Hz, Pf:0.85
Amps:3307, Insulation Class Rotor/Stator: F/F, Phase Connection:Star
Excitation Volts/Amps:250/1035, Spec:Iec 34.3
Machine Number:62034a-Ig Year Built:1995
Brushless Exciter
Brush, Frame:Bxj40-20, Continuous Rating, Spec:Iec 34.3, Insulation: Class F
Dc Volts/Amps:225/1138, Field Volts/Amps:51/7.2
Machine Number:62034a-1e Pmg
Frame:Pmx 34-10, Rpm:3000, Phase/Hz:1/400, Volts/Amps:200/15
Machine Number: 62034a-1p
Turbine Inlet Air Filter With Housing
Aaa Filter House, Av-6 W/L, Style Code: Coalescep Duravee 90
Model Number:107-1710409-B, Control Number: 442-025, Size:294000 Cfm
Generator Inlet Air Filter And Exhaust Air With Housing
Turbine Exhaust Stack Upwards 50 Feet
Lube Oil Skid With Pumps Etc.
Turbine And Generator Housing With Fire Protection System
Distillate Fuel Divider, Manifold.
Fuel Treatment Module With Pump
Piping Connection Point With Isolation Valves From Fuel Barge To Power Barge.
Internal Piping
Generator Line Side And Neutral Side Cubicles
Lube Oil Air Fin Fan Cooler
C) Control Room
Westinghouse Wdpf Ii Turbine Control Panel
Ep Voltage Regulator
Generator Protection Panel
Dc Battery Charger, Mcc. Dc Motor Starter
Impedance: 11.5%
Auxiliary Transformers
Virginia Oil Filled, 750 Kva, 3 Phase, 50 Hz, 11,500 V To 400 Grdy/230 V
Al Winding, 65 Deg C Rise,
Virginia Oil Filled, 1,500 Kva, 3 Phase, 50 Hz, 11500 V To 6900 Y/3985
Al Winding, Total Weight:14,000 Lbs,
Westinghouse Ampguard Motor Starters
Mcc Room With MCC
Fire Pump With Motor
Air Compressor Atlas Copco Model Zt45 Product Number 8972432779,
With Air Receiver.