Commercial
Industrial
and Institutional
Applications
Leviton … Leading the Way
in GFCI Protection at Home
and on the Job
There’s no compromising with safety standards when
it comes to reducing the hazards of electrical shock.
Leviton GFCI receptacles meet and exceed Underwriter
Laboratories (UL) and National Electrical Code (NEC)
requirements for residential, commercial and industrial
applications. Our GFCI line is the culmination of over
25 years of design and development expertise. From
advanced technology SmartLock® devices with lockout
action to portable cord sets and power distribution
centers, Leviton GFCIs offer the ultimate in personnel
protection and safety for all your needs.
1. Kitchen
2. Bathroom
3. Garage/Carport
4. Utility Room/Laundry Room 3
5. Workshop
6. Outdoor Locations
7. Pool/Whirlpool Spa
8. Decks and Porches
2
Table of Contents
How GFCIs Protect You
The Need for Ground Fault Protection . . . . . . . . . . . . . . . . . . 4
New UL Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Technical Information
National Electrical Code (NEC) Requirements . . . . . . . . . . 19-21
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23
Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . 24-25
2
7
8
3
How GFCIs Protect You
1. Plug a lamp or radio 2. Turn ON lamp or radio. 3. Push the TEST button on 4. Push the RESET button
into the SmartLock the SmartLock GFCI. on the SmartLock GFCI
GFCI receptacle. The GFCI will trip and to restore power to the
power to the lamp or lamp or radio.
radio will be cut off.
To Test a Non-SmartLock GFCI
Follow steps 1-4. If the GFCI does not trip when you push the TEST button and power to
the lamp or radio is not cut off, contact a licensed electrical contractor.
IMPORTANT: The SmartLock RESET button will not restore power if the GFCI is damaged
and cannot respond to a ground fault. The RESET button on a non-SmartLock GFCI will
always restore power, even if the GFCI is damaged and cannot respond to a ground fault.
5
SmartLock® Advanced GFCI Receptacles
Thick-walled, impact-resistant
thermoplastic nylon cover and
body withstand abuse
Heavy-duty contacts are double wipe for
15 Amp and triple wipe for 20 Amp
Look for the Lock when Lockout action blocks the Optional LED indicator offers Advanced electronics design
choosing a GFCI. The lock “RESET” button if GFCI visual confirmation of power provides superior resistance to
ensures improved GFCI protection has been availability electrical surges and
performance compromised over-voltages
Spec Grade
15A SmartLock® Duplex GFCI with LED Indicator Light
Rated 15A-125V at NEMA 5-15R Receptacle,
20A-125V Feed-Through – Back and Side Wired G
W
Black and Red Buttons with Wallplate TM
Monochromatic Buttons
Packed in a Box
Cat. No. Color UPC Inner Pack Standard Pack
010-8598-000 Brown 07847713599 0 ---- 10
011-8598-00I Ivory 07847713600 3 ---- 10
012-8598-00W White 07847713601 0 ---- 10
015-8598-00A Almond 07847713602 7 --- 10
Monochromatic Buttons
Packed in a Box 5-20R
7
SmartLock® Advanced GFCI Receptacles
Spec Grade
15A SmartLock® Duplex GFCI
Rated 15A-125V at NEMA 5-15R Receptacle, G
20A-125V Feed-Through – Back and Side Wired W
Spec Grade
20A SmartLock® Duplex GFCI
Rated 20A-125V at NEMA 5-20R Receptacle, G
Monochromatic Buttons with Wallplate/Self-grounding Clip – Contractor Pack (5 GFCIs per Box)
Cat. No. Color UPC Inner Pack Standard Pack
025-8899-CPI Ivory 07847717475 3 5 50
026-8899-CPW White 07847717477 7 5 50
027-8899-CPA Almond 07847717478 4 5 50
9
SmartLock® Advanced GFCI Receptacles
Hospital Grade
15A SmartLock® Duplex GFCI with LED Indicator Light
Rated 15A-125V at NEMA 5-15R Receptacle, G
Spec Grade
SmartLock® Combination Switch/GFCI Receptacle
Rated 15A-125V at NEMA 5-15R Receptacle,
G
20A-125V Feed-Through – Back and Side Wired W
10
GFCI Personnel Protection Devices
Agency Standards
• Complies with UL Standard 943 as a
Recognized Component Class A GFCI
power supply with open neutral Choice of Automatic or
protection Manual reset models
– UL Listed (File #E-48380),
15A devices also Power indicator light goes OFF if
CSA Certified (File #LR-5781) GFCI trips, power is interrupted
or line cord is unplugged
• Fully complies with NEC code
article #527.6, 6(A) and 6(B)
and OSHA regulation CFR 1926- Water-resistant enclosure sealed
404b(i)(ii) for construction sites by ultrasonic welding to ensure
long service life
Automatic Reset GFCI Cord Sets and Extension Cords – Black Body
• Automatically resets to ON when plugged in or after power interruption
• Available in 2-ft, 6-ft and 25-ft lengths except where indicated
Automatic Reset – Black Body
Length NEMA Configuration
Cat. No. Description/Rating (In Feet) Plug End Connector End
66591-2C 15A-125V GFCI Cord Set 2’
G
5-15R W
5-15R G
W
5-15R G
W
W
W
Right-Angle GFCIs
• Complies with UL Standard 943 Class A GFCI operation
with open neutral protection
• Right-angle design provides ease of use in a variety of locations
• Ideal for use with spa units, high pressure washers, building
maintenance equipment, submersible pumps, and a wide
variety of portable equipment
• Available with manual reset (yellow body) or automatic reset
(black or gray body). Manual reset versions will not reset to ON
after power interruption, helping to avoid potential accidents
with power tools
• Accepts 3-wire flexible cord, No. 18 (.300")—No. 12 (.450")
cord diameter range
• Housing and wiring terminal chamber sealed with silicone
rubber gaskets for superior protection against moisture and dust
• Specially designed Raintight-While-In-Use Cover, NEMA 3R
rated, available to protect right angle GFCI plug when used in
wet locations
• UL Recognized Component E-48380
13
GFCI Personnel Protection Devices
High-Current GFCI
Cat. No. Description Color
8895-00I 80A-120/240V 60Hz. Back & Side Wired Ivory
8895-00W White
8895-00E Black (Ebony)
Note: A panel mount Equipment Leakage Circuit Interrupter (ELCI) is also available.
Contact your Leviton representative for information
14
GFCI Personnel Protection Devices
Power Cords
Cat. No. Description
KRS-A9519 50 ft. Temporary Power Cord w/Weather-Resistant 50A, 125/250
Plug and Connector
KUS-A9519 100 ft. Temporary Power Cord w/Weather-Resistant 50A, 125/250
Plug and Connector
15
GFCI Wallplates and Accessories
Weather-Resistant
Flush Cover Wallplates
• Self-closing
• Vertical and horizontal mounting
• Die-cast zinc covers and base
• Weather-resistant gaskets
• Stainless steel springs
2 YEAR LIMITED
16
GFCI Wallplates and Accessories
17
GFCI Wallplates and Accessories
18
Technical Information – NEC Codes
Residential – Interior
2002 NEC Article No. Application Applicable GFCI Cat. No.
210.8(A)(1),(5),(6) and (7) Bathrooms, storage/work areas, unfinished basements, 8599, 8899
kitchen counter tops and wet bars
Combination Switch/GFCI replaces standard switch or 8299
switch/outlet to provide GFCI protection; saves expense
of installing separate GFCI wallbox
406.3(D) When no grounding conductor is available, replace 8598, 8599, 8898, 8899
non-grounding receptacles with GFCI
550.13(B) Outdoor, bathroom, and kitchen receptacles in mobile 8299, 8599, 8899
homes and manufactured homes
680.44 Outlet(s) that supply power for self contained spa 8590, 8899
or hot tub
Residential – Exterior
2002 NEC Article No. Application Applicable GFCI Cat. No.
210.8 (A)(2),(3),(4),(8) Garages, exterior locations, crawl spaces, boathouses 8598, 8599, 8898, 8899
680.22(A)(1),(5), (B)(4) Swimming pool equipment, lighting and nearby areas 8598, 8599, 8898, 8899
680.23(A)(3)
680.32
680.42, 680.43, 680.44 Outlets, power supply cords, lighting and equipment 8598, 8599, 8898, 8899
for spas and hot tubs
Cat. No. 8299-W Cat. No. 8599-W Cat. No. 8598-W Cat. No. 8899-W
15A Combination Switch/GFCI 15A GFCI Receptacle 15A GFCI Receptacle 20A GFCI Receptacle
with Indicator Light
AS SEEN ON
19
Technical Information – NEC Codes
21
Technical Information – Dimensional Drawings
15A SmartLock Advanced GFCI 20A SmartLock Advanced GFCI Blank Face GFCI
8598/8599 8898/8899 8590
15A Automatic Reset GFCI Cords 20A Automatic Reset GFCI Cords Right Angle GFCI Plug
26591/66591 36591/66891 6593/6893
(9.32 ± 2 mm) 2.50 (63.5 mm) (9.32 ± 2 mm) 2.50 (63.5 mm)
1.29
1.60 (33 mm)
(41 mm)
1.83
(46.5 mm)
RESET TEST
20
20
20
20
20
20
30
m)
12 5m
.0 49
(30 .5(
5m 19
m)
22
Technical Information – Dimensional Drawings
3.13 (79.4 mm) 0.26 0.19 3.50 (88.9 mm) 0.26 0.19
(6.6 mm) (4.8 mm)
(6.6 mm) (4.8 mm)
Nylon and Metal
Plastic Nylon and Metal
Plastic
23
Technical Information – Frequently Asked Questions
When the line and load leads are reversed CORRECT WIRING GFCI Receptacle Face
connected directly to
(right), the GFCI receptacle face is now wired load side terminals
directly to the power coming from the panel,
completely bypassing the internal switching Power in from panel
To downstream
receptacles
mechanism. The face is not GFCI protected N
and remains live even after the internal Line Side Load Side
switch opens. This is a potentially hazardous Terminals
PC Board
Terminals
What’s the Difference Between Line/Load Line/Load Reversal Power reaches GFCI
receptacle face before
WRONG!
Reversal and Reversed Polarity? going through switch – GFCI
receptacle is always live
24
Technical Information – Frequently Asked Questions
Although the National Electrical Code has required 2-pole, 3-wire grounding circuits for several
years, there are still many homes with 2-pole, 2-wire circuits and 2-prong receptacles. You cannot
simply bring these homes up to modern code standards by replacing non-grounding receptacles
with the 3-prong grounding types. A qualified electrician will have to verify that there is a
continuous ground path at each receptacle, which may require circuit rewiring. An alternate
solution is to install a GFCI in place of the non-grounding receptacle.
Section 406.3 (D) of the National Electrical Code permits a non-grounding type receptacle to be
replaced with a grounding type receptacle without a grounding connection. However, the
grounding receptacle must be GFCI-protected.
The diagram below shows a typical non-grounding (2-prong) receptacle replaced with a GFCI.
The GFCI must be marked, “No Equipment Ground.” The GFCI can feed through to a grounding
receptacle, which must be marked “GFCI Protected. No Equipment Ground.”
For increased electrical
safety, Leviton strongly
recommends installing a
GFCI in every non-
grounding circuit. A
ground wire provides
protection by offering a
parallel path back to
ground for any fault
current. Without a ground wire, fault current will try and take other paths to ground and a GFCI
will trip and cut power under these hazardous conditions. Ground faults are more likely to occur
in non-grounding circuits and a GFCI will help protect family members from this potentially
hazardous condition.
25
SmartLock® GFCI Packaging and Merchandising
SmartLock® GFCI Packaging – Have It Your Way
SmartLock® GFCIs are available in five different packages. Most have windows that reveal
device color, button color, amperage, and “the lock” on each device, ensuring that you have
an authentic SmartLock GFCI.
Without Wallplate: With Wallplate
• Single-Unit Boxed • Decorative GFCIs with Matching Buttons
• 3-Pack Boxed • Child Safety GFCIs with Red/Black Buttons
• Contractor Packs with Red/Black Buttons or Matching Buttons
I-3