Sei sulla pagina 1di 1

Control Valve - Gas, Steam or Vapor flow 10/2/2017

GAS LIFT CHOKE VALVE

Project 60. INSTALLATION OF CHOKE VALVE ON GDM. CV CALCULATION

Tag number Gas Lift Choke Valve By OBUM


App 34543
Input data
Valve
Data : 1 in Globe : Linear. Ports : Two. Flow to : Between
Rated Cv : 3.7. Rated xT : .68. Rated FL : .9. Style Fd : .32

Pipe sizes
Inlet : 1 in. Outlet : 1 in. Outlet pipe wall : .358 in

Fluid data
Name : Compressed HC Gas Gas property factor: 1 dbA
Maximum Normal Minimum Units
Percent of system flow - - - - - - - - 100 80 10
Gas flow - - - - - - - - - - - - - - - - - - 1 .8 .115 Msft3/d
Pressure drop - - - - - - - - - - - - - - 2 2 2 bar
Flow temperature - - - - - - - - - - - 45 45 45 degC
Inlet pressure - - - - - - - - - - - - - - 72 72 72 barg
Cp/Cv Sp heat ratio - - - - - - - - - - 1.5 1.5 1.4
Molecular weight - - - - - - - - - - - - 18.56 18.56 18.56
Density @ FTP - - - - - - - - - - - - - 57 57 57 kg/m3
Accoustic efficiency - - - - - - - - - - .000001369 .000001369 .000001369

Output data
Required Cv - - - - - - - - - - - - - - - 3.2098 2.5679 .36947
Percent of valve Cv - - - - - - - - - - 87 69 10
Noise level: - - - - - - - - - - - - - - - - 44 43 35 dbA
Status - - - - - - - - - - - - - - - - - - - - Normal Normal Normal
Sonic minimum size - - - - - - - - - - .1506 .1347 .05105 in

Selection based on NA Model NA

Notes

Potrebbero piacerti anche