Sei sulla pagina 1di 1

CT-Bolt M20

CT-M20 Minimum load capasities


Yielding load Ultimate load
(kN) (kN) Structural properties B500NC
Point-anchored M20 123 147 Yield strength 500 MPa/ N/mm^2

Fully grouted D20 157 188 Ultimate strength 600 MPa/ N/mm^2

Loads are calculated without safety factor Based on the characteristic value in NS 3576-3

Minimum Value / Type Unit Symbol Value Core diameter - bar 20 mm


Thread dimension M20X2,5 Material - Rebar bolt B500NC
Thread cross-sectional area mm At 245 Corrosion protection CombiCoat/galvanized
Rebar cross-sectional area mm Ar 314 Weight CT-M20 - 3m 10,9 kg
Yield strength N/mm Rp0.2 500 Borehole diam. 45 - 52 mm
Ultimate strength N/mm Rm 600 Borehole length Bolt length + 0,2m
Ultimate load strain % Agt 8

Vik rsta AS P.O. Box 193 N-6151 rsta l.: +47 70 04 70 00 www.vikorsta.no