Sencera Co., Ltd.

Alcohol module specification.

AT110M1
Specifications:
d etecting point : 0.25mg/L (can be changed). (0.05%BAC US, 0.5%BAC UK ;
preset from us) O perating temperature range: 0-40
S ize: 78mm 40mm 23mm.
W eight :30g, excluding batteries .
I ndicating way : Red color LED.
W arm-up time : less than 10 seconds.
B atteries: 3VDC (2 A AA batteries)

Using Manual
1.Input 2 pcs AAA 1.5V battery into the module.
2.Push up the switch to the TEST position, The green and yellow LED on.
The yellow LED will light during warm-up, 10 seconds later, the yellow
LED will black out, only green LED lights, The tester enter detecting
status.
3.Face to the gas entrance on top of the module, you can breath out gas
directly, the tester will detect and indicate the alcohol concentration in the
breathed gas. If the alcohol concentration in your blood <0.05%BAC
(pre-set level). Than will not have LED turn on. It means alcohol
concentration in your blood havent exceed the standard. If the alcohol
concentration in your blood >0.05%BAC, the Red LED on the module will
light on.

www.sensorelement.com sales@sensorelement.com
Tel: 886-937029101 Fax:886-2-27041279
Sencera Co., Ltd.
4.Push down the power supply switch to Lamp, the LED light on for lighting
function. In the lighter state the system without detecting function.

After completing testing, please close the power supply avoiding battery
sources waste. During the testing, when the yellow LED on, It means the
battery exhausted and need to replace.

AT110M2
Same function with AT110M1. But change the switch to push button.
When you push the button the module will power on and pre-heat to ready
than waiting for detecting. Push button also will turn on the lighter function.

Release the power button than the system and lighter function will turn off.

AT110M3
Similar function with AT110M2. But just for two LED and no lighter function.
Button cell to instead of AAA battery will be acceptable. But operating time
is much shorter than AAA battery source.

Push the button for power on and pre-heat system than to ready for test.
In the pre-heating state, the RED LED will light on. After complete the
pre-heating state, the RED LED will turn off. If the sensor detect the
concentration over the pre-set level than the RED LED will light on again.
User should push button continuously during the operating period.

Release the button the system will turn off.

Notification for the mentioned 3 modules.


1If there is much disturb gas exit in the detecting area, it may influence the
testing accuracy.
2As different people has different endurance, this testing result only for
reference, not for a subject standard for driving.

www.sensorelement.com sales@sensorelement.com
Tel: 886-937029101 Fax:886-2-27041279