Sei sulla pagina 1di 71

1

Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc


CONTENIDO

PRESENTACION .........................................................................................................................3
1. COMUNICACION CON EL PROGRAMA ......................................................................5
1.1. COMO USAR EL MOUSE ...........................................................................................5
1.2. USO DEL TECLADO.....................................................................................................5
1.3. LOS BOTONES DE LA BARRA DE HERRAMIENTAS .............................................6
1.4. COMO INICIAR CHEMCAD ........................................................................................6
1.5. INICIANDO UN NUEVO TRABAJO LA VENTANA DE SIMULACIN...............8
2. PROPIEDADES FSICAS .................................................................................................11
2.1. COMANDOS DE PROPIEDADES FSICAS ..............................................................11
2.2 ACCESANDO AL COMPONENTE DATABANK ....................................................12
3. EQUIPOS DE TRANSFERENCIA DE MASA................................................................18
3.1 DESTILACIN: SEPARADOR PROPANE-PROPYLENE ........................................................18
4. EQUIPOS DE TRANSFERENCIA DE CALOR.............................................................49
4.1 INTERCAMBIADOR DE CASCO Y TUBOS ..........................................................................49
5. SIMULACIN DE REACTORES ....................................................................................63
5.1 REACTOR TUBULAR PFR ...............................................................................................63
6. SIMULACION DE SISTEMAS DE BOMBEO .................................................................67
6.1 BOMBAS CENTRIFUGAS..........................................................................................67

2
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
PRESENTACION

Este manual de instruccin proporciona las tcnicas bsicas de entrada para


operacin con CHEMCAD operativo. CHEMCAD es un programa demasiado fcil de
aprender, y la mejor manera de aprender es usndolo. Aqu proveemos una
descripcin paso a paso de cmo solucionar el problema del estabilizador de
condensado dado a continuacin. El procedimiento de entrada es simple . Este se ha
diseado para ser intuitivo para un ingeniero qumico familiarizado con el medio
ambiente . Sin embargo, por el bien de la claridad y para usuarios nuevos, se da una
revisin de algunas de las reglas bsicas para CHEMCAD.

Pasos bsicos:

1. Iniciar un nuevo trabajo


2. Seleccin de unidades de ingeniera
3. Crear un flowsheet
4. Seleccin de componentes
5. Seleccin de opciones termodinmicas
6. Definicin de las corrientes de alimentacin
7. Entrada de parmetros de equipo
8. Correr la simulacin
9. Revisin de los resultados
10. Generacin de una copia de salida

Los pasos no tienen que ser realizados en esta orden ni todos ellos tienen que
estar hechos para cada flowsheet. Todo debera considerarse para cada problema.

Hay una serie de instalaciones de ayuda (Help) disponibles a todo lo largo del
programa. La lea del fondo describe ligeramente el item marcado por el cursor. El
comando Help provee una va de entrada para el Manual en Lnea que contiene
informacin tcnica integral. La tecla [F1] le provee al contexto la ayuda sensitiva
3
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
(coloque el cursor en un campo de aplicacin y presione la tecla[ F1]). El uso de estas
ayudas le facilitar el uso del programa.

CHEMCAD esta orientado a objetos. Por consiguiente, la mayora de entrada y


la edicin pueden hacerse haciendo doble clic o haciendo clic derecho sobre el objeto
de la operacin, as como tambin usando los comandos del men.

Todas las corrientes y especificaciones de unidades de operaciones (entrada)


son efectuadas usando ventanas de dilogo. Estas ventanas de dilogo son contexto
especfico y utilizan alguna combinacin de campos de carcter, cuadros combinados,
cajas de primera calidad y casillas de verificacin.

4
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
1. COMUNICACION CON EL PROGRAMA

1.1. COMO USAR EL MOUSE

El mouse es muy fcil para usar y conseguir que la computadora haga lo que
usted quiere. CHEMCAD, al igual que muchos programa de Windows, requiere el uso
de un mouse, trackball, o dispositivo similar de orientacin con ambos un botn
primario y secundario (o sea un mouse de 2 botones Microsoft estndar). Las tcnicas
bsicas Mouse estn resumidas debajo:
Clic Para presionar y soltar el botn primario (normalmente el botn
izquierdo) del ratn.

Clic-derecho Para presionar y soltar el botn secundario (normalmente el botn


derecho) del ratn.

Doble-Clic Para presionar el botn primario dos veces en sucesin rpida.

Arrastrar Para presionar y mantener presionado al botn primario del ratn al


mover el ratn.

Puntear Mover la flecha del ratn hasta tocar el artculo de eleccin.

Mantener clic Apunte hacia un rea especfica, entonces clic y mantenga el botn
derecho secundario del ratn

1.2. USO DEL TECLADO

La tecla [TAB] es usado para moverse hacia el siguiente campo sobre una caja de
dialogo de entrada.
Las teclas [PgUp] y [PgDn] pueden ser usadas para "paginas" o enrollar a travs de
listas.

5
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Manteniendo apretado [SHIFT + TAB] causar que el programa se mueve hacia atrs
o arriba de un campo.
La tecla [F1] se usa para llamar contexto ayuda especfica.
La tecla [F5] exhibir la lista de componentes actual.

1.3. LOS BOTONES DE LA BARRA DE HERRAMIENTAS

La forma "Estndar" de ejecutar rdenes en CHEMCAD es hacer un clic sobre


un comando en la Barra de Men (Menu Bar) y mantener esa orden detenida a travs
de los subsiguientes mens hasta que la funcin deseada sea cumplida. As, para
seleccionar componentes del banco de datos (databank), primero se debe hacer clic en
el comando ThermoPhysical en la Barra de mens; hacer un clic sobre Component
List del Menu ThermoPhysical la cual es exhibida, y, finalmente, seleccione los
componentes de la caja de dilogo Component Selection.

Hay una forma ms corta de alcanzar esto y otras funciones frecuentemente


usadas. Esto es usando CHEMCAD Power buttons, los cules estn ubicados en la
barra de herramientas. Esta barra de herramientas es activada y desactivada usando
el comando View/Toolbar.

1.4. COMO INICIAR CHEMCAD

La primera vez que usted ejecute CHEMCAD aparecer en su pantalla la ventana


de inicio del programa. Por favor maximice esta ventana (para copar toda la pantalla)
dando un clic sobre el botn Maximize en la esquina superior derecha de la ventana
CHEMCAD. Se ver lo siguiente:

6
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Fig.2 Inicio de CHEMCAD
La lnea del tope es llamada la Barra de ttulos. Contiene el logotipo CHEMCAD y
nombre en el lado izquierdo, y las VENTANAS minimice, tile, y close buttons en el
lado derecho.
La siguiente lnea es llamada la Barra de mens. Esta barra contiene las rdenes
del ms alto nivel para CHEMCAD. Son:
File Este comando es usado para definir formatos de salida, abrir trabajos,
imprimir y obtener informacin general sobre CHEMCAD
View Esta orden faculta al usuario a desplegar y esconder la barra de
herramientas y la barra de estado de vez en cuando.
Help Esta funcin da al usuario permiso de llamar las facilidades de ayuda en
lnea.
La tercera lnea (o barra) es llamada la Barra de herramientas. Contiene los
smbolos para directamente invocar atajos para las funciones diversas del archivo que
de otra manera se gan acceso a travs de los mens.
Lo dems de la ventana est inactivo en este nivel.
La ventana actual exhibe slo lo del ms alto nivel de CHEMCAD. CHEMCAD
tambin tiene otras ventanas para la instalacin y corrida de una simulacin, generar
documentos PFDs, crear y editar grficos, etc. En el transcurso de este manual de
instruccin, usted se introducir en estas ventanas y su uso.

7
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
1.5. INICIANDO UN NUEVO TRABAJO LA VENTANA DE
SIMULACIN

Comencemos abriendo un nuevo trabajo y dndole un nombre de trabajo. La


orden File sirve para esto. Para abrir el men File, d un clic sobre la palabra File en la
barra de mens.
Ahora escoja la opcin New Job haciendo clic en ella.
Se abre la siguiente caja de dilogo:

Fig. 3 Caja de dilogo par nuevo trabajo

Esta ventana de dilogo le advierte para introducir un nombre y carpeta para el


nuevo trabajo. Usemos el nombre TUTOR1. Por favor introduzca este nombre en el
campo designado File Name. Luego cierre la ventana de dilogo haciendo clic en el
botn [Save].
Ahora se le har ingresar a la ventana principal de trabajo de CHEMCAD la cual
aparece inmediatamente.
Esta ventana contiene el espacio de trabajo para colocar el diagrama de flujo y la
paleta de unidades de equipo y corrientes, la cual se activa o desactiva con el botn
S/G de la barra de Mn

8
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Fig. 4 Ventana de trabajo de CHEMCAD

Las caractersticas principales de esta ventana son etiquetadas arriba y son


descritas a continuacin:
La lnea del tope, llamada Title Bar, (Barra de ttulos), ahora contiene el logotipo
CHEMCAD y el nombre del trabajo uqe se est haciendo, as como tambin los
comandos, minimize, title, y close que estn siempre presentes en el lado izquierdo.
La Barra de mens sigue a la Barra de ttulos y consta de quince rdenes adems
de la orden Help. Estas rdenes son:

File (Archivo) Para el manejo del archivo y control de impresin

Para modificar aspectos diversos del flowsheet y su


Edit (Edicin) presentacin. Las funciones de edicin incluyen a Redraw,
Undo, Redo, Cut, Copy, Paste, Delete, Flip, y Rotate 90 entre
otros.

View (Ver) Para controlar diversos despliegues y opciones de dibujo

Format (Formato) Para hacer una seleccin de unidades de diseo, ajustar


9
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
opciones de grficos, e importar mapas de bits.

Run Para cambiar de decisin de ac para all entre el modo Edit


Simulation/Edit Flowsheet (Editar diagrama de Flujo) y el modo Run Simulation
Flowsheet (Ejecutar Simulacin).

Para seleccionar mtodo (s) de Valores-K para componentes, y


ThermoPhysical
mtodos para entalpas para el trabajo actual, as como
tambin, ver y editar el CHEMCAD databanks (base de datos);
Establecer las curvas de destilacin y definir slidos.

Para entrar, editar, y manipular corrientes y datos de


Specifications
operaciones de la unidad. Esto tambin puede hacerse dando
doble clic directamente sobre la corriente o Unidad de
operacin en el flowsheet.

Para ejecutar las simulaciones, as como para definir las


Run
ordenes de clculo

Results Para revisar los resultados del clculo

Plot Para desplegar los resultados grficamente

Para preparar reportes y Diagramas de Flujo de Procesos


Output
(PFDs).

Para dimensionar y evaluar clculos para tipos diversos de


Sizing
equipo.

Tools Para las actividades diversas asociadas con la simulacin.


Estos incluyen regresin de datos, CO2 slidos y la

10
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
prediccin de hidratos, los clculos TOD/COD, y otros.

Window Para arreglar despliegue de ventanas y de iconos.

Help Para llamar al sistema de ayuda de CHEMCAD

La Barra de mens es seguida por la Barra de herramientas. La barra de


herramientas contiene "botones de poder" o atajos para especificar las funciones
frecuentemente usadas. Estas funciones de la barra de herramientas estn clarificadas
en un posterior captulo de este gua.
Debajo de la Barra de herramientas est el rea Activa. Notar que esta rea est
acompaada por la barra elevador para desplazar lnea a lnea el despliegue activo
del rea a lo largo y a lo ancho, y derecha e izquierda. Debido a que nosotros todava
no hemos dibujado nuestro flowsheet, la rea Activa es ahora espacio vaco excepto
por la Main Palette (Paleta Principal).
La Main Palette (Paleta Principal proporciona acceso a las funciones grficas y
smbolos los cuales son necesarios para la creacin del flowsheet.

2. PROPIEDADES FSICAS

2.1. COMANDOS DE PROPIEDADES FSICAS

Este manual est relacionado con las funciones ofrecidas por las siguientes rdenes:
2.1.1. Bajo el Men ThermoPhysical:
El commando Databank con sus subcommandos:
View-Edit
New Component
Copy Component
Delete Component
Plot Properties
Neutral file import List
User Components

11
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
El comando Distillation Curve
2.1.2. Bajo el men Tools:
El comando Pure Regresin

2.2 ACCESANDO AL COMPONENTE DATABANK

2.2.1. Men View-Edit

Del comando Thermophysical sobre el men principal seleccione Databank. Esto le


permite a usted acceder al banco de datos de componentes de CHEMCAD. A partir de
este men, usted puede adicionar nuevos componentes al user databank o editar
propiedades para componentes existentes. Usted no puede cambiar ningun valor en
Chemstations databank directamente. Sin embargo, usted est permitido a copiar
components desde Chemstations databank al users databank, luego edite estos
como user-defined compounds.
Siguiendo a las entradas en el Databank Menu que aplican para ambos el estndar y
el databank del usuario.
Es el nmero de identidad ID del componente que controla ya sea que los
componentes pueden ser editados o mirados (slo los componentes con nmeros ID
entre 6000 y 10000 pueden ser editados).

Ejemplo 2.1
Ver propiedades de un componente: Clorometano (Chloromethane)
Comenzamos por seleccionar el comando View-Edit del Men Databank, el cual se
encuentra en el Men ThermoPhysical sobre la Menu Bar, de la siguiente manera:

Apareciendo la ventana de dilogo Select One Component from DataBank


12
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
En esta ventana, en el espacio nombrado como Search, escribimos el nombre del
componente: Chloromethane o el ID, si se tiene.

Si no aparece sombreado el nombre del compuesto Chloromethane, hacer clic sobre


el botn Next hasta que aparezca el nombre exacto del componente (si es que est
bien escrito y est en la base de datos)
Cuando aparece el nombre correcto del componente, se hace clic en el botn OK y
aparece la ventana de dilogo View/Edit Component Data.
En esta ventana estn los submens con todas las propiedades fsicas para el
Chloromethane

13
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Seleccionaremos el submen Basic Data y aparece la ventana con los datos bsicos

Haciendo clic en el botn Cancel se cierra esta ventana y regresamos a la ventana


View/Edit Component Data. En esta ventana volvemos a seleccionar otra opcin
como por ejemplo Print Component Data para imprimir los datos del componente, o
Plot Component Data para graficar algunas propiedades del componente como
funcin de alguna variable (generalmente la temperatura). En este caso seleccionamos
la presin de vapor usando la Ec. de Antoine.
14
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Apareciendo la grfica

2.2.2 Men New Component


En este caso se trata de estimar propiedades fsicas para componente que no esta en
en la base de datos del programa
Para ilustrar el procedimiento de la estimacin de propiedades fsicas, estimaremos las
propiedades fsicas del componente 1,1,2-Timetilciclohexano (1,1,2-
Trimethylcyclohexane usando el mtodo de Joback. Este es un mtodo de
contribucin de grupos (Ref. Reid, Prusnitz & Poling The Properties of Gases and
Liquids)
Comenzamos por seleccionar el comando New Component del Databank Menu, el
cual se encuentra en ThermoPhysical Menu sobre la Menu Bar, de la siguiente
manera:

15
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Cuando hace click en el comando New Component, aparece la caja de dilogo New
Components.
Como estamos usando el mtodo de Joback , debemos completarlo como sigue:

No es necesario suministrar el punto de ebullicin normal (normal boiling point), pero


hacindolo mejora la exactitud de los resultados estimados (proporcionando, desde
luego, un NPB correcto). Luego de completada la caja de dilogo, hacer click sobre el
botn OK.
Aparece la caja de dilogo Group Assignments. El 1,1,2-Trimethylcyclohexane tiene
los siguientes grupos:

La caja de dilogo Group Assignments, debe ser completada como sigue:

16
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Al hacer click sobre el botn OK, aparecer la siguiente caja de dilogo.

Al hacer click sobre el botn YES, aparecer la siguiente caja de dilogo de


confirmacin

Click OK. El programa le permitir a usted que mire y/o revise los resultados de la
estimacin exhibiendo el men View/Edit Component Data.

El total de las estimaciones se guardar en la ventana de dilogo Basic Data. Por


consiguiente, d un clic sobre este artculo ahora.

17
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
3. EQUIPOS DE TRANSFERENCIA DE MASA

3.1 Destilacin: Separador Propane-Propylene

3.1.1 Enunciado del problema

El propano y propileno son muy difciles de separar uno de otro, ya que son
componentes que hierven cerca. No obstante, la destilacin a presin elevada es una
tecnologa comn, con tal que exista suficiente nmero de bandejas en la columna de
destilacin.
En este ejemplo, se presentan clculos de una torre con 148 bandeja reales. El
modelo de destilacin SCDS (Mtodo de correccin simultnea) se usa para acomodar
un nmero grande de bandejas, y dar explicacin sobre bandejas reales.
El equilibrio liquido-vapor Propane/propylene y ethane/ethylene son afectados por
interacciones entre los componentes. Se usan los parmetros especiales de interaccin
binaria para la Ecuacin de Estado de Peng-Robinson para reflejar estas no
idealidades

18
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
La composicin de la alimentacin es:

lbmol/h
Flujos
Ethane 0.3000
Propylene 550.0000
Propane 200.0000
N-Butane 5.0000
La alimentacin se hace como vapor a 240 psia.
El proceso exige obtener un destilado en e el cual la fraccin molar de propano no
sea mayor a 0.4 por ciento y la fraccin molar de propylene en las colas sea alrededor
de 4 por ciento (esto se obtiene de un balance preliminar).

3.1.2 Confeccin del diagrama de flujo

1. Abrir CHEMCAD
2. Seleccionar Nuevo trabajo
3. Guardarlo con el nombre de PROPPSPLT
Al guardar el archivo aparece en la pantalla la siguiente Figura:

19
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
4. Seleccin de Unidades
Luego que se ha dado el nombre al trabajo, seleccione el comando Format ya
sea presionando [ALT+ M] o haciendo clic con el ratn. Aparecer el siguiente men:

Ahora seleccionamos la opcin Engineering Units haciendo clic con el ratn y


aparece la siguiente caja de dilogo:

Por defecto se tiene el sistema INGLES (ENGLISH) de unidades. Para este


trabajo usaremos el sistema de Unidades de Ingeniera INGLES, por lo que salimos de
la caja de dilogo haciendo clic en el botn Cancel.

3.1.3. Seleccin del equipo


De la paleta de iconos de equipo, seleccionamos el correspondiente a SCDS
columnas (en la 7ma fila y 4ta columna).
20
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Hacemos clic derecho sobre el icono y en la parte superior izquierda de la pantalla
aparece la siguiente sub-paleta

Hacemos clic izquierdo sobre la primera columna (equipo seleccionado), el


submen desaparece y el cursor se transforma en un cuadrado.
Luego hacemos clic izquierdo sobre la ventana del diagrama de flujo, apareciendo
el icono de la columna y apareciendo nuevamente la paleta de unidades de equipo,
quedando de la siguiente manera.

21
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Si necesitaramos otros equipos deberamos repetir el procedimiento. En nuestro
caso solamente vamos a simular una columna por lo que ahora debemos colocar las
corrientes de alimentacin y producto.
Si se hace clic izquierdo sobre cualquier icono de la paleta principal,
automticamente la paleta se cierra y el cursor se transforma en un cuadrado, al hacer
nuevamente clic izquierdo sobre la ventana del DF, se selecciona la primera opcin de
la sub-paleta correspondiente a dicho icono y aparece nuevamente la paleta principal.
Como se observa en la ventana de diagrama de flujo, no es necesario mover la
paleta para colocar otros equipos, solamente basta con mover los cursores para
desplazar el espacio de trabajo.

3.1.3. Corrientes de Alimentacin y Productos


1. Alimentacin. Seleccionamos el icono correspondiente a alimentacin (FEED) en la
paleta principal.

22
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Al hacer clic derecho sobre el icono aparece la siguiente sub-paleta

Seleccionamos Feed #1, hacemos clic izquierdo sobre este icono desaparece la
sub-paleta y el cursor se transforma en un cuadrado.
Arrastramos el cursor sobre al lugar donde deseamos colocar la alimentacin y
hacemos clic izquierdo, con lo cual se coloca la alimentacin sobre el diagrama de flujo,
desaparece la sub-paleta y aparece nuevamente la paleta principal para continuar con
el trabajo

Colocar alimentacin Alimentacin colocada

2. Producto. Seleccionamos el icono correspondiente a producto (Product)

Al hacer clic derecho sobre el icono aparece la siguiente sub-paleta

23
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Seleccionamos Product #1, hacemos clic izquierdo sobre este icono desaparece
la sub-paleta y el cursor se transforma en un cuadrado.
Arrastramos el cursor sobre al lugar donde deseamos colocar el (los) producto (s)
y hacemos clic izquierdo, con lo cual se coloca el (los) producto (s) sobre el diagrama
de flujo

Colocando productos
Productos colocados

Ahora debemos pasar a colocar las lneas de corrientes


3. Lneas de Corrientes. Seleccionamos el icono correspondiente a las lneas de
corrientes (Stream)

Hacemos clic izquierdo sobre este icono y desaparece la paleta principal, el cursor
se transforma en una cruz y al acercarlo a cualquier unidad de equipo, alimentacin y
producto, el cursor se transforma en un sealizador y en las unidades aparecen las
conexiones de entrada y salida. Para conectarlos colocamos el cursor en una conexin
de salida, hacemos clic izquierdo (con lo cual aparecen dos lneas guias) y lo
arrastramos hasta una conexin de entrada en donde hacemos nuevamente clic
izquierdo con lo cual queda trazada la lnea de corriente y el cursor nuevamente se

24
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
transforma en una cruz. Este procedimiento lo volvemos a repetir hasta tener todas las
lneas de corriente.

Trazo de corrientes Dibujo Final

Al colocar las lneas se van enumerando automticamente segn el orden de


trazado
Si una linea ha sido mal trazada, hacemos clic izquierdo sobre la lnea, se marca la
lnea con cuadrados y se borra la lnea (Delete)

3.1.4. Seleccin de Componentes


Seleccionando el comando ThermoPhysical, se desplegar el men
correspondiente y hacer clic en la opcin Component List, o directamente en el icono
correspondiente en la barra de tareas.

Apareciendo la caja de dilogo de componentes en la cual definimos los


componentes presentes en la alimentacin.

Ahora guardemos la lista haciendo clic en el botn [OK].

25
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
3.1.5. Opciones Termodinmicas
Usando el comando ThermoPhysical localizado en la barra de men y luego,
punteando y haciendo clic sobre la opcin K-values sobre el men desplegado

o directamente haciendo clic en el icono de la barra de Men.

Por favor hacer esto. La caja de dialogo de K-value Option ser desplegada, la
cual esta actualmente resaltada. Abra esta ventana haciendo clic en ella. Su pantalla
ahora mostrar lo siguiente:

En el cual seleccionamos la opcin: Peng-Robinson

3.1.6. Definicin de la Alimentacin


Hacemos doble clic en la corriente nmero 1 y aparece la siguiente caja de
dilogo:

26
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
En esta caja de dilogo colocamos:
1. Nombre de la corriente (opcional)
2. Cantidades de cada componente (que han sido seleccionados previamente) en
unidades definidas previamente (en este caso henos definido sistema Ingls:
lbmol/h). Automticamente el programa suma y da el flujo total
3. Dos condiciones entre: Temperatura, Presin, Fraccin de vapor o entalpa. En
nuestro caso tenemos Presin = 240 psia y Fraccin de vapor = 0. Con estas dos
condiciones y la composicin, automticamente el programa calcula las dems
propiedades.

3.1.7. Parmetros del Equipo

Los parmetros bsicos para simulacin de la columna son:

Pgina 1:

1. General

Tipo de Condensador : Ingresar el tipo de condensador como sigue:

0 Condensador Total
1 Condensador Parcial
2 Condensador Total - con decantador
3 Condensador Parcial - con decantador
Para la opcin 0, condensador total - con dos fases, el destilado ser liquido.
Seleccionamos la opcin: 0 Total condenser
27
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
2. Presin en el Tope (o Presin en el Condensador) : Si no se ingresa un valor, se
usar la presin de la primera alimentacin.
Colocamos: Top Pressure = 220 psia

3. Cada de presin en la columna: Ingrese la cada de presin a travs de la


columna y el rehervidor como un nmero positivo. La Presin en cada Plato ser
calculada por linearizacin de la presin entre el tope de la columna (excluyendo el
condensador) y el fondo de la columna (incluyendo al rehervidor si este existe).
Colocamos: Colm Press drop = 30 psia

4. Nmero de etapas/ Segmentos: Para modelo VLE Regular, este es el nmero de


etapas incluyendo el condensador y rehervidor. Las etapas son numeradas desde el
tope de la columna. Si est presente un condensador, este es tratado como la etapa
1. Si est presente un rehervidor, este es tratado como etapa N. Tericamente, no
hay lmite para el nmero de etapas. El nmero de etapas permitido depende de la
memoria del computador y el nmero de componentes en el sistema. El mnimo
nmero de etapas es 2.
Para modelos de platos de transferencia de masa, este es el nmero de platos
tericos (no ideales) en la columna. Plato 1 y N son el condensador y el rehervidor,
si est presente.
Colocamos: No of Stages = 150

5. Ubicacin de la etapa de alimentacin: Las etapas de alimentacin debes ser


ingresadas desde el tope hacia el fondo. El nmero de ubicaciones de etapas de
alimentacin debe ser igual al nmero de corrientes de alimentacin a la columna.
Calentadores/enfriadores laterales son ingresados como corrientes de entalpa
(corrientes tienen entalpa y no flujo de componentes), y las ubicaciones deben ser
ingresadas como etapas de alimentacin.

Ejemplo: SCDS 9 5 3 -7 -6
1st etapa de alimentacin: 3
28
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
2nd etapa de alimentacin: 10
3rd etapa de alimentacin: 24

En el ejemplo anterior, la columna tiene tres corrientes alimentaciones de


alimentacin. La corriente 9 ingresa sobre la etapa 3, corriente 5 ingresa sobre etapa
10 y corriente 3 ingresa sobre etapa 24.
Una alimentacin ingresando a un condensador o rehervidor es permitido. Si usted
requiere mltiples corrientes de alimentacin ingresando a la misma etapa, debe ser
usado el mdulo MIXER (Mezclador) antes de la columna.
Colocamos: Feed tray for stream 1 = 110

6. Modelo de Simulacin: Seleccione el modelo Regular VLE model Para usar el


modelo SCDS normal para una columna de N etapas. Este modelo asume equilibrio
de mezcla en cada etapa. Las opciones de transferencia de masa usan las
difusividades de Maxwell-Stefan y correlaciones empricas para calcular la matriz de
los coeficientes totales de transferencia de masa.

7. Eficiencia de la etapa del tope: Ingrese la eficiencia de plato de Murphee en el tope


de la columna. El valor por defecto es 1.
Colocamos: Top Stage efficiency = 0.9

8. Eficiencia de etapa del fondo: Ingrese la eficiencia de plato de Murphee en el


fondo de la columna. El valor por defecto es 1.
Colocamos: Last Stage efficiency = 0.9
Luego la primera pgina quedar:

29
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Pgina 2: Specifications

9. Condenser mode: Seleccione las especificaciones del condensador del men


siguiente:
Mode no. Specification
0 No condenser
1 Reflux ratio
2 Condenser heat duty, negative
3 Condenser temperature
4 Total distillate mole flow rate
5 Distillate mole flow rate of one component
6 Mole fraction of one component in the distillate
7 Split fraction of one component in the feed streams to the distillate
8 Fractional amount of feeds in the distillate
9 Molar flow ratio between two components in the distillate
10 Distillate mass flow rate
11 Distillate component mass flow rate
12 Distillate component mass fraction
13 Distillate std liquid volume flow rate

30
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
14 Reflux mole flow rate
15 Reflux mass flow rate
Seleccionamos: 12 Distillate component mass fraction (fraccin en masa de un
componente en el destilado)

10. Especificacin del Condensador: Ingrese la especificacin del condensador de


acuerdo al modo de condensador seleccionado anteriormente. La carga de calor en
el condensador debe ser un nmero real negativo. Si el modo es 0, este valor no es
necesario.

Ejemplo A: Condenser mode = 1


Condenser specification = 2.3

Especifica una razn de reflujo de 2.3.

Ejemplo B: Condenser mode = 2


Condenser specification = -2.3 MMBtu

Especifica una carga de calor en el condensador de -2.3 MMBtu.

Para modos 5, 6, 7, 11, 12, condenser component i spec.


Esto es requerido para modos de condensador 5, 6, o 7. Ingrese la posicin del
componente en la lista de componentes si la especificacin de un cierto componente
en el destilado es necesario.

Ejemplo: Condenser mode = 5


Condenser specification = 25.7 lbmol/hr

Condenser component i spec. = 3

Especifica el flujo del tercer componente en el destilado a ser 25.7 lbmol/hr.

Para mode 9, comp i and comp j


Es necesario para modo 9 de condensador el cual requiere la especificacin de dos
31
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
componentes. Ingrese la posicin del componente para componentes i y j.

Ejemplo: Condenser mode = 9


Condenser specification = 0.03
Condenser ratio position 1 = 4

Condenser ratio position 2 = 3

Moles de flujo de comp 4/molees de flujo de comp 3 = 0.03 en el destilado.


Para nuestro ejemplo deseamos que la fraccin molar de propano en el destilado no
sea mayor a 0.4
Especificamos: Specification = 0.004
Component = 3 Propane
11. Select reboliler mode: Seleccione las especificaciones del rehervidor del men
siguiente:
Mode no. Specification
0 No reboiler
1 Boil-up ratio V/B
2 Reboiler heat duty, positive
3 Reboiler temperature
4 Total bottom mole flow rate
5 Bottom mole flow rate of one component
6 Mole fraction of one component in the bottom
7 Split fraction of one component in the feed streams to the bottom
8 Fractional amount of feeds in bottom
9 Molar flow ratio between two components in the bottom
10 Bottom mass flow rate
11 Bottom component mass flow rate
12 Bottom component mass fraction
Modo 0 significa sin rehervidor (tal como un absorbedor). Cualquier otro modo
mayor que cero indica que el rehervidor existe y las especificaciones son
proporcionadas.
32
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Seleccionamos: 12 Bottom component mass fraction (fraccin en masa de un
componente en los fondos)
12. Reboiler specification: Ingrese la especificacin del rehervidor de acuerdo al
modo seleccionado anteriormente. La carga de calor en el rehervidor debe ser un
nmero real positivo. Si el modo es 0, este valor no es necesario.

Ejemplo A: Reboiler mode = 4

Reboiler specification = 213.5 lbmol/hr.

Especifica un caudal molar de fondos como 213.5 lbmol/hr.

Ejemplo B: Reboiler mode = 2

Reboiler specification = 42.3 MMBtu

Especifica una carga de calor en el rehervidor de 42.3 MMBtu.

Reboiler component i spec.


Esto es requerido para modos de rehervidor 5, 6, 7, 11, o 12. Ingrese la posicin
del componente en la lista de componentes si la especificacin de un cierto
componente en el fondo es necesario.

Ejemplo: Reboiler mode = 5


Reboiler specification = 25.7 lbmol/hr.
Reboiler component i spec. = 3

Especifica el flujo del tercer componente en los fondos a ser 25.7 lbmol/hr.

Reboiler mode = 9 comp i and comp j


Esto es requerido para modo de rehervidor 9. Ingrese la posicin de componente
para componentes i y j.

Ejemplo: Reboiler specification = 0.01


33
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Reboiler ratio position 1 = 4
Reboiler ratio position 2 = 5

Especifica flujo molar de comp = 4/flujo molar de comp 5 = 0.01 en los fondos.
Para nuestro ejemplo deseamos que la fraccin molar de propileno en los fondos no
sea mayor a 4
Especificamos: Specification = 0.04
Component = 3 Propylene
Luego la segunda pguina quedar:

Ahora hemos completado el ingreso de datos para la columna. Guardemos estos


datos haciendo clic en el botn [OK]. Cuando usted hace esto recibir el siguiente
mensaje de advertencia:

Los mensajes de advertencia, son para su informacin y pueden normalmente


ser ignorados; por lo tanto hacer clic en [Yes]. Esto retornar a usted a la ventana de
simulacin. El total de los datos de entrada al flowsheet estn ahora completos.

34
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
3.1.9. Efectuando la Simulacin
Para efectuar la simulacin puntear y hacer clic sobre el comando Run de la barra
de men. Esto hace que se abra el men Run de la manera siguiente:

Nosotros queremos hacer un anlisis de estado estacionario, as seleccionamos la


opcin Run All.
El programa primero chequear los datos y listar cualquier error y/o
advertencia en la pantalla. En este caso no debemos tener errores, aun cuando nos de
mensajes de advertencia que no hemos hecho ciertos estimados

Nosotros podemos ignorar estas advertencias y proceder haciendo clic en el botn


[Yes]. Los clculos se efectuarn.
Cuando se han finalizado los clculos aparece en la pantalla CHEMCAD
Messaje Box con el mensaje: Recycle calcultion has converged

Para cerrar esta caja de dilogo y limpiar la pantalla, debemos hacer clic en [OK]
3.1.10. Revisin de Resultados
Ahora que la simulacin se ha completado, debemos revisar los resultados antes
de imprimirlos o hacer una copia. Hacemos esto usando los comandos Results y Plot
35
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
de la barra de men. Con estos comandos, inspeccionamos si hemos conseguido
nuestros criterios de diseo.
En este caso, nuestro criterio de diseo es que se haya conseguido la separacin
con las especificaciones de propane y propylene en el destilado y las colas
respectivamente:
Hacemos doble clic en la corriente 2 (Fondos) y aparece la hoja con los resultados
de la simulacin:

Verificamos la fraccin molar de propylene: 8.929519/211.855 = 0.042 (cercano al


especificado)
En la parte superior colocamos el nombre de la corriente: Fondos
De igual manera, hacemos doble clic en la corriente 3 (Destilado) y aparece la hoja
con los resultados de la simulacin (en este caso ya hemos colocado el nombre
:Destilado):

Verificamos la fraccin molar de propane: 2.074517/543.4449 = 0.0038 (Menor del


mximo permisible - Aceptable)
Por lo tanto la simulacin es correcta. Ahora veremos que informacin podemos
obtener de la simulacin
Opciones del comando Results
1. Select Flow Units. Para seleccionar las unidades de flujo para los reportes
36
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Al hacer clic aparece la siguiente caja de dilogo

Fijamos Moles y hacemos clic en OK


2. Stream Compositions. Composicines de las corrientes.

37
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
En este caso seleccionamos. All Streams (todas las corrientes). Al hacer clic, se abre
Word pad y se tiene la siguiente informacin:

Si seleccionamos la opcin: Unit Streams (corrientes de una unidad) nos da las


corrientes de entrada y salida a una unidad de proceso, para lo cual al hacer clic
aparece la caja de dilogo donde debemos colocar el nmero de la unidad, ID en este
caso 1.

Colocamos el nmero de la unidad y hacemos clic en OK, cerrandose esta caja de


dilogo y apareciendo las corrientes de entrada y salida a la unidad. En este caso debe
ser una tabla similar a la anterior.
Notar que el programa al ejecutar este comando coloca a la alimentacin antes que los
fondos y ya no tiene en cuenta el orden de ID de las corrientes.

38
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
2. Stream Properties. Propiedades de las corrientes, tiene un sub-menu igual al de
composicines y trabaja de la misma manera.
3. Unit Ops. Proporciona todas las especificaciones para una unidad seleccionada. Al
hacer clic aparece la caja de dilogo para colocar el ID de la unidad.

Colocamos 1 y hacemos clic en OK. Se abre Word Pad y la informacin relacionada a


la columna:

3. Topology. Como van las corrientes (desde y hacia donde)


4. Thermodynamics. Modelos usados para calcular valores_K y entalpas
5. Tower Profiles. Perfiles de la torre dando Temperatura, Presin, y los flujos molares
de liquido y vapor en cada etapa. (hay que ingresar el ID de la unidad seleccionada)
6. Tray Compositions. Da la composicin en los platos. Para esto hay que ingresar el
ID de la unidad y luego aparece la siguiente caja de dilogo:

Para seleccionar en que platos que deseamos ver las composiciones. Al hacer clic en
OK, se abre Word Pad y aparecen las composiciones en los platos seleccionados( en
este caso 5 - 10)

39
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
6. Tray Properties. Trabaja igual que para composiciones, al ingresar el ID de la
Unidad abre Word Pad y aparecen las propiedades termodinmicas de todos los platos.
7. Tower Mass Transfer. Muestra el modelo de transferencia de masa. En este caso
no se ha indicado modelo de transferencia de masa.
8. Distillation Curves. Evala el BP a diferentes presiones para una corriente
seleccionada.
9. Batch Results. Para sistemas por lotes
10. Particle Size Distribution. Para sistemas con la presencia de partculas slidas.
10. Convergence. Informacin acerca de los clculos realizados
Opciones del comando Plots
1. Tower Profiles. Para dibujar los perfiles de Temperatura y composiciones dentro de
la columna

Al hacer clic aparece la siguiente caja de dilogo

Seleccionamos perfil de temperatura hacemos clic en OK. Apareciendo el perfil de


temperatura

40
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
2. TPXY. Nos da valores X vs Y del componente ms voltil para una mezcla de dos (o
tres componentes). Al hacer clic aparece la siguiente caja de dilogo:

Seleccionamos Propylene (ligero) Propane (pesado) y damos los dems valores. Al


hacer clic en OK, aparece la siguiente tabla (con 100 puntos):

Al cerrar esta tabla aparecen las grficas siguientes:

41
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Si deseamos editar la grfica, podemos seleccionar las opciones deseadas del men
Graph
Y as sucesivamente podemos obtener otras grficas para nuestro trabajo.

3.1.11. Produccin del Reporte


Para esto usamos la opcin Output sobre la barra de men. el cual tiene las
siguientes opciones:

Job Note Para escribir notas acerca del trabajo


Report Para generar una copia tabular de las salidas.
Main PFD Para producir y editar diagrama de flujo el principal del proceso.
New PFD Para producir diagramas de flujo adicionales.
Open PFD Para editar diagramas de flujo de procesos diferentes al principal
PFD.
1. Report. Haciendo clic sobre Report o presionando la tecla [R], aparecer el
Report Menu.

42
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
1.1 Report Formats

1.2 Select Streams. Al seleccionar Select streams y hacer clic en OK. Aparece la
siguiente caja de dilogo:

Colocamos las corrientes 1 2 3, separadas por un espacio y al hacer clic en OK,


se cierra esta caja.
Si deseamos verificar las corrientes seleccionadas hacemos clic nuevamente
en Select streams y aparece:

43
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
1.3 Select Unit Operations. Trabaja igual que Select Streams pero para las unidades
de equipo.
1.4 Stream properties

1.5 Stream Flowrate/Composition

1.6 Distillation Summaries del menu. Aparecer la ventana de dilogo Distillation


Options

44
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
y permitir a usted que haga lo siguiente:
1. Tray profile Imprimir un resumen tabular de los perfiles por plato para la
columna, es decir, para cada etapa el programa imprimir la temperatura,
presin, flujo de vapor, flujo de liquido y cualquier alimentacin o producto yendo
hacia o desde la etapa.
2. Tray properties Un resumen tabular de las propiedades de transporte
del vapor y el liquido en cada etapa de la columna.
3. Tray sizing Resultados de los clculos de tamao de los platos para
cada etapa de la colomna. El usuario puede seleccionar platos a vlvula,
perforados o con casquetes de burbujeo.
4. Packed column sizing Dimensiones de las columnas empacadas y
resultados de los clculos de cada de presin.
5. Tray compositions Composiciones por etapa pueden ser impresas en
flujos de masa o molares as como tambin en fracciones molares o de masa.
Solamente una puede ser seleccionada.
Vamos a imprimir solamente los perfiles de los platos descritos en el item 1
anterior. As como usted puede ver del checkmark sobre la ventana de dilogo, esta
es la opcin por defecto. Entonces por favor hacer clic en [OK] para retornar al
Report Menu.

Estamos ahora en condiciones de generar nuestro informe. Por favor puntear y


hacer clic en la opcin la cual dice Calculate and Give Results del Report Menu.
Cuando usted hace esto, el reporte ser desplegado en una ventana de notas
(Notepad) y si tiene instalado el Word, aparecer en Word.
45
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Este ser formateado exactamente como aparece.
Para imprimir estos resultados hacer clic en el botn Print.
Como ya hemos finalizado con el reporte, cerrar la ventana de notas. Aparece la
ventana principal de CHEMCAD. Usted puede generar ms reportes yendo a Output y
Report, cuando acaba de hacer sus reportes puede cerrar la ventana de Report Menu
hacienda clic en End Report. Y retornar a la ventana principal de CHEMCAD.

3.1.12. Generacin del Diagrama de flujo


Seleccionando Main PDF del men Output aparece la siguiente sub-paleta para
trabajar el DF

Creando una ventana de datos de Corrientes

Ahora, colocaremos el balance de materiales y calor para el flowsheet sobre la pantalla.


Esta informacin est contenida en una ventana de datos de corriente. Una ventana de
datos de la corriente es creada usando el siguiente procedimiento.
1. Clic en el comando Output para activar la subpaleta para arreglo del DF
2. Clic en el comanfo Format en la barra de men. La ventana del men Format
aparecer.
3. Clic en la opcin Add Stream Box del Men Format.

46
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
4. Aparecer la ventana de dilogo Select Streams.

Por defecto estn incluidas todas las corrientes. Por consiguiente, d un clic sobre
el botn [OK] para cerrar la ventana de dilogo.
5. Aparecer la ventana de dilogo Databox Property Options:

Esta ventana de dilogo es usada para seleccionar que tems (para cada
corriente) debe ser incluido en la ventana de datos. Los tems son seleccionados
haciendo clic en el cuadrado junto a ellos. Una checkmark indicara el item que debe ser
incluido. Un cuadrado vaco indica que el tem no ser incluido.
para prepsitos de esta demostracin aceptamos lo establecido por defecto.
Entonces hacer clic en el botn [OK] para cerrar esta ventana y guardar los items
establecidos.

47
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
6. Aparecer una ventana Data Box Settings para determinar la forma y el tamao de
letra

Guardamos los valores establecidos por defecto y cerramos la ventana haciendo


clic en [OK]. Aparecer la tabla con los datos de las corrientes la cual se mostrar
de la siguiente manera:
Y el Diagrama de flujo con la informacin adicional ser:

48
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
4. EQUIPOS DE TRANSFERENCIA DE CALOR

4.1 Intercambiador de Casco y Tubos


4.1.1 Enunciado del problema

Se desea enfriar de Metanol desde 90 oC hasta 40oC , para tal efecto se debe
usar agua de enfriamiento disponible a 25 oC y puede calentarse hasta 40 oC. La
presin de entrada del metanol es 5 atm y se permite una cada de presin de hasta
0.5 atm. La presin de entrada del agua es 6 atm y se permite una cada de presin de
hasta 0.6 atm.

4.1.2 Confeccin del diagrama de flujo

1. Abrir CHEMCAD

2. Seleccionar Nuevo trabajo

3. Hacer el diagrama de flujo y guardarlo con el nombre de CASCOYTUBO

49
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
4.1.3 Seleccin de Unidades

Luego que se ha dado el nombre al trabajo, seleccione el comando Format ya


sea presionando [ALT+ M] o haciendo clic con el ratn.

Ahora seleccionamos la opcin SI y hacemos algunos cambios por ejemplo: Flujo


de masa (Kg), Temperatura (C) y Presin (atm), para coincidir con las unidades del
enunciado del problema.

Y luego OK

4.1.4. Opciones Termodinmicas

An cuando en este caso no es necesario especificar opciones termodinmicas,


es preferible seleccionar una opcin termodinmica siguiendo los pasos generales para
todo trabajo en CHEMCAD.

Usando el comando ThermoPhysical localizado en la barra de men y luego,


punteando y haciendo clic sobre la opcin K-values sobre el men desplegado

50
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
o directamente haciendo clic en el icono de la barra de Men.

y en este caso hemos seleccionado UNIFAC

4.1.5. Especificacin de corrientes

Hacemos doble clic en la corriente que deseamos especificar y luego colocamos


los datos respectivos

1. Entrada de METANOL: Especificamos Temperatura de entrada, Presin y cantidad


de la corriente

Nombre de la corriente (opcional)

2. Salida de METANOL: Especificamos Temperatura de entrada, Presin


(considerando la cada de presin mxima) y cantidad de la corriente

51
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
3. Entrada de AGUA: Especificamos Temperatura de entrada, Presin y cantidad de la
corriente

Nota: Estamos especificando una cantidad de 60000 kg/h de agua y veremos ms


adelante que esta cantidad es pequea por lo que deberemos de aumentarla

4. Salida de AGUA: Especificamos Presin (considerando la cada de presin mxima)


y cantidad de la corriente. No especificamos temperatura de salida

4.1.6. Parmetros del Equipo

Para esto ingresamos al Men: Specificatios y escogemos Select Unitops

Luego tipeamos el ID de la unidad que deseamos especificar

52
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Los parmetros bsicos para simulacin del intercambiador son:

Pgina 1: Specifications

1. Simulation Mode:

0 Especificaciones para la simulacin con CHEMCAD


1 Ingresar Geometria del Intercambiador (Simulacin con CCTHERM)

2. Temperatura de salida dela corriente 2 (METANOL)= 40 C

3. Cadas de presin:

Corriente 1 (METANOL) = 0.5 atm.


Corriente 2 (AGUA) = 0.6 atm.

Pgina 2: Misc Settings

1. Type: En este caso seleccionamos la opcin

0 En contracorriente

53
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
2. Presiones de salida
P1 4.5 atm (METANOL)
P2 5.4 atm (AGUA)

3. Numero de intercambiadores en serie: 1

4. Numero de pasos en el casco y en los tubos


Casco 1 paso
Tubos 4 pasos
Es un intercambiador 1-4

4.1.7. Efectuando la Simulacin

Clic derecho sobre intercambiador y :Run This Unit

54
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Verificamos la temperatura de salida del agua de enfriamiento: Hacemos doble
clic en la corriente (4) y vremos que la temperatura es de salida del agua de
enfriamiento: 53 C.

Como nosotros deseamos que la temperatura de salida sea: 40 C, lo lgico es


aumentar la cantidad de agua de enfriamiento, por lo que hacemos doble clic en la
corriente (1) y colocamos 110000 kg/h en lugar de 60000 kg/h. Hacemos clic en OK

Volvemos a hacer clic derecho sobre intercambiador y :Run This Unit

Verificamos la temperatura de salida del agua de enfriamiento: Hacemos doble


clic en la corriente (4) y vremos que la temperatura es de salida del agua de
enfriamiento: 40 C. (cumple con lo especificado)

4.1.8. Especificaciones finales del Intercambiador

Especificamos caractersticas del intercambiador para lo cual seleccionamos


Sizing Shell & Tube

55
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Aparece la caja de dilogo para colocar el ID de la unidad seleccionada:

Despues de colocar el ID de la unidad, hacer clic en OK

Como se han cambiado los datos de la corriente aparece el siguiente mensaje

Aparece el mensaje para ingresar la corriente que va por los tubos

Cli en Aceptar aparece

Aparece Heat Curve Parameters

56
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
No cambiamos nada y clic en (Ok)

Aparece la Grfica

Hacemos clic en (OK) Aparece Menu de especificaciones

Opciones del Men de Especificaciones del Intercambiador

1. Heat Curve Parameters. Para ver la grfica de las temperaturas de las corrientes

2. Edit Heat Curve. Aparece una tabla con los valores de las variables. Al hacer clic en
OK, Aparece una caja de dilogo para interpolar datos entre los valores extremos

Al hacer clic en SI aparece la tabla enterior con datos de las variables


interpolados entre los extremos. Al hacer clic en OK de la tabla aparece
nuevamente la caja de dilogo anterior para guardar laos datos interpolados. Hacer
clic en SI

57
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
3. General Specifications. Especificaciones bsicas del intercambiador

Modeling Methods. Por defecto

Clic en OK

4. Exchanger Geometry. Para ver las caractersticas del intercambiador seleccionado

4.1 Tube Specifications

58
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
4.2 Shell specifications

4.3 Baffle specifications

4.4 Nozzle specifications

59
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
4.5 Clearence Specifications

4.6 Material

4.7 Miscellaneous

60
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
5. Calculate. Esta opcin es para efectuar todos los clculos en el intercambiador con
las especificaciones dadas del intercambiador

6. View Results. Luego de efectuar los clculos podemos ver todos los resultados de
la simulacin,para lo cual seleccionando esta opcin, se despliega una caja de dilogo
con el siguiente men:

4.1.9 VER RESULTADOS DE LA SIMULACION

Para ver Resultados: Sizing Shell & Tube

61
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
apareciendo la caja de dilogo para indicar ID de la unidad

Al colocar el ID y hacer clic en OK

Donde seleccionamos lo que queremos ver.

Complete la simulacin Produciendo el reporte y adicionando las corrientes al DF

62
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
5. SIMULACIN DE REACTORES

5.1Reactor Tubular PFR

5.1.1 Enunciado del problema


Se trata de la deshidrogenacin del etano mediante la reaccin:
C2H6 ------------> C2H4 + H2
El etano vapor ingresa al reactor tubular a temperatura de 1100 K y a presin de
6 atm, a razn de 6.014 kg/h. Se desea una conversin de etano de 0.8
5.1.2 Confeccin del diagrama de flujo
1. Abrir CHEMCAD
2. Seleccionar Nuevo trabajo
3. Hacer el diagrama de flujo y guardarlo con el nombre de REACTOR
4. Seleccionar Kinetic Reactor ( y de estos la opcin # 1)

5. Colocar la alimentacin, el producto y las lneas de corriente, con lo cual se tiene:

5.1.3 Definir Componentes


22 Ethylene

63
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
3 Ethane
1 Hydrogen

5.1.4 Unidades de Ingeniera


Format Engineering Units : METRIC y cambiar Mass/Mole : Kg y
Temperatura: K Presn : atm
5.1.5 Opciones Termodinmicas
Thermophysical: K-Values: Ideal Vapor pressure
5.1.6 Opciones para Balance de Energa
Thermophysical: Entalphy: No entalphy (no hacemos balance de energa)
5.1.7 Editar las Corrientes
1. Editar corriente 1:
Temperatura: 1100 K
Presin: 6 atm
Vapor fraction: 1
Ethylene:
Ethane: 6.014 kg/h
Hydrogen
5.1.8 Especificaciones del Reactor
Pgina 1
Nmero de reacciones: 1
Specify reactor type: PFR (Plug Flow)
Vapor only
Isothermal
Specify conversion, calculate volume
Conversion: 0.8
Key component: 2 Ethane

64
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Pgina 2
Activation E/H of Rxn Unit: 2 MMBtu
Volume Units: Cubic meters
Molar Flow-Units: 1-K-moles
Time Units: 0 Hours
Mass Flou Units: 1 Kg

Pgina 3
Frequency factor: 3
65
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Component Stoichometric coefficient Exponential factor

2 Ethane -1 1

1 Ethylene 1

3 Hydrogen 1

5.1.9 Efectuando la simulacin


Run all
5.1.10 Generando el reporte

Format Add Stream box ( Colocar Mole Flow rates) OK

5.1.11 Acomodar el DF

66
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
6. SIMULACION DE SISTEMAS DE BOMBEO

6.1 BOMBAS CENTRIFUGAS

6.1.1 Enunciado del problema

De un tanque cerrado provisto de un respiradero a la atmsfera se desea


bombear agua a 20 C (68 F), hacia una torre de absorcin. El nivel de liquido en el
tanque se encuentra a 7,0 m (19,7 pies) sobre el eje de la bomba, el caudal es de 20,0
m3/h (88 gpm).

La conexin de entrada del agua en el tope de la torre se halla a 20,0 m (65,6


pies) sobre el nivel del eje de la bomba.

La lnea de succin consiste de tubera de acero estndar de 2" (5,08 cm) de


dimetro nominal, No. de cdula 40S y 40,0 m (131,2 pies) de longitud, posee 4 codos
estndar y una vlvula de compuerta ("gate") abierta.

La lnea de descarga tambin es de acero estndar de 2" (5,08 cm) de dimetro


nominal, No. de cdula 40S y 60,0 m (198,6 pies) de longitud, tiene 2 codos estndar, 2
T usadas como codo y una vlvula de control, la presin manomtrica en la torre de
absorcin es de 137,9 kPa (20 psig).

6.1.2 Confeccin del diagrama de flujo

1. Abrir CHEMCAD
2. Seleccionar Nuevo trabajo
3. Hacer el diagrama de flujo y guardarlo con el nombre de SISBOMBEO
4. Seleccionar Pipe Simulator

67
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
5. Colocar la alimentacin, el producto y las lneas de corriente, con lo cual se tiene:

6.1.3 Definir Componentes


62 Water
6.1.4 Unidades de Ingeniera
Format Engineering Units : ENGLISH y cambiar Mass/Mole : Kg y
Temperatura: F Presn : psia

6.1.5 Opciones Termodinmicas


Thermophysical: K-Values: SRK

6.1.6 Opciones para Balance de Energa


Thermophysical: Entalphy: No entalphy (no hacemos balance de energa)

6.1.7 Editar las Corrientes


1. Editar corriente 1:
Temperatura: 68 F
Presin: 14.7 psia
Water: 20000 kg/h
68
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
6.1.8 Especificaciones del Simulador de tubera 1
Pipe Sizing and Rating (PIPE)
Method (fluid flow):
4. Water (Hazen-Williams)
Sizing Option
0 Rating. This is the default. El usuario debe ingresar el tamao de la
tubera
1 Single phase flow. El programa selecciona el tamao de la tubera
C factor: Factor usado en le Ec. de Hazen-William. El valor por defecto es 120. El
usuario puede especificar este valor para el Method 4: Hazen-Williams.
Pipe diameter: Dimetro nominal de la tubera
DP/100 ft. (for sizing): Si se usa opcin 2 (Size Option) ingresar la cada de presin por
100 ft a ser usada
Pipe length: Longitud de la tubera (no incluye accesorios)
Pipe schedule: Opcional
Roughness: El valor por defecto es 0.00015 feet. El usuario puede sobrescribir este
valor si desea.
Elevation Change: Carga de elevacin (Columna esttica) Valor positivo (+) indica que
la tubera est yendo hacia arriba y Valor negativo (-) indica que la tubera va hacia
abajo

69
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Recomendable correr esta unidad para tener una idea de la cada de presin y verificar
la corriente 2 ( en caso contrario especificar corriente 2)
Bomba (ID 1)

Se ajusta la presin de salida para dar compensar la cada de presin del lado de la
descarga Y correr la unidad para verificar corriente 3
70
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc
Simulador de tubera (ID 2)

Se corre todo el diagrama y se va ajustando la presin de salida de la bomba hasta


obtener la presin de salida del sistema (corriente 6) deseada.

BIBLIOGRAFA
Manual de ChemCad versin 5.x
Manual de ChemCad versin 6.x

71
Manual de ChemCad Ing. Tefilo Donaires Flores, M.Sc

Potrebbero piacerti anche