During their recent spring teleconference meeting, the Research Administration Committee (RAC)
reviewed the subject Research Topic Acceptance Request (RTAR) and voted 4-0-0 to reject it. The
following list summarizes the consensus review comments and questions on this RTAR:
1. The proposed topic, advancement, work scope does not seem to justify funding this effort
as an ASHRAE Research project.
2. This RTAR does not include sufficient information to evaluate the approach and budget.
By rejecting this RTAR, RAC is strongly suggesting to the TC that this particular topic be dropped
from the TC research plan based on the information that has been provided.
If the TC wishes to pursue this topic further, please address the above issues noted by RAC in a
revised version of the RTAR with the help of your Research Liaison, Stephen Hancock
RL6@ashrae.net, prior to submitting it to the Manager of Research and Technical Services for
further consideration by RAC. In addition, a separate document providing a point by point
response to each of these comments and questions must be submitted with the RTAR. The
response to each item should explain how the RTAR has been revised to address the comment, or
a justification for why the Technical Committee feels a revision is unnecessary or inappropriate.
The RTAR and response to these comments and questions must be approved by the Research
Liaison prior to submitting it to RAC.
The next submission deadline for RTARs and WSs is May 15, 2013 for consideration at the
Societys 2013 annual meeting. The submission deadline after that is August15, 2013.
Project ID 1695
Comparison of Computational Methods of Flexibility Analysis to Computer Modeling to Determine
Project Title Thermally Developed L-Bend Z-Bend, and U-Bend Anchor Forces
Sponsoring TC TC 6.1, Hydronic & Steam Equipment Systems
Cost / Duration $50,000/ 6M
Submission History 1st Submission
Classification: Research or Technology Transfer Basic/Applied Research
RAC SPRING 2013 REVIEW SUMMARY
Check List Criteria VOTED NO Comments & Suggestions
Is there an adequate description of the approach in order #13 - This RTAR doesn't include sufficient information to evaluate the approach/budget. #8 - $50 k seems to be a high request considering the
for RAC to be able to evaluate the appropriateness of the amount of information provided on the approach. #6 - Yes, the description of the approach is adequate, it is just that the problem being addressed
budget? If not, then the RTAR should be returned for revision. #13, #8, #15 does not seem too significant, and the approach is some simple calculations. #15 - Inadequate description of the approach
Initial
Decision Options Decision Approval Conditions
#13 - There is very little information in this RTAR and it needs to be rewritten with enough information to properly judge its merits. #6 - There just
does not seem to be enough here to justify an ASHRAE research project.
ACCEPT
COND. ACCEPT
RETURN
REJECT
ACCEPT Vote - Topic is ready for development into a work statement (WS).
COND. ACCEPT Vote - Minor Revision Required - RL can approve RTAR for development into WS without going back to RAC once TC satisfies RAC's approval condition(s)
RETURN Vote - Topic is probably acceptable for ASHRAE research, but RTAR is not quite ready.
REJECT Vote - Topic is not acceptable for the ASHRAE Research Program
Unique Tracking Number Assigned by MORTS ____1695-RTAR________________________
RESEARCH TOPIC ACCEPTANCE REQUEST (RTAR) FORM
(Generally 2 to 6 pages, with 10 pt Times New Roman font)
Sponsoring TC/TG/MTG/SSPC/EHC/REF: _TC 6.01____________
Title:
Goal 9: Support the development of improved HVAC&R components ranging from residential through
commercial to provide improve system efficiency, affordability, reliability, and safety.
Objective: The improvement of HVC&R components is a continuous, never ending process, with the
current state-of-the-art being the collective result of work by organizations and companies over years and
the application of a rule of thumb. The opportunity to re-evaluate anchor forces generated in thermally
developed L-bends and U-bends is one such case.
Technical Challenge: There is a simple methodology to calculate the anchor forces generated by
thermally developed in L-bends and U-bends in Chapter 45 of the 2008 Systems Handbook. The very
conservative forces generate by this equation has been brought to T.C. 6.1 attention several times.
Research: Conduct computer modeling of anchor forces generated in thermally developed L-bends and U-
bends over a range of lengths, temperatures, and pipe sizes and compare the results to results from a
previous study. The comparison shall conform to ASME (American Society of Mechanical Engineers)
standards. The model will analyze L-bends, Z-bends, and U-bends in air and one buried media for bonded
piping.
Research Classification:
Basic/Applied Research
TC/TG/MTG/SSPC Vote: Reasons for Negative Votes and Abstentions:
For 7 Against-0 Abstentions- 0
Absent- 4 Total 11
Estimated Cost: Estimated Duration:
$50,000 6 months
RTAR Lead Author Expected Work Statement Lead Author
Contact has been initated with the following firms:ECE Developers of Caesar II, Perma-Pipe,
Thermacor, Urecon, Mason Industries, ITT Grinnell, AutoDesk, SST Systems, Bentley, and Rovanco.
1
Application of Results:
The results will be used to update the anchor force equations in Chapter 46 of the 2012 System
Handbook.
State-of-the-Art (Background):
There are four separate equations that are used to calculate anchor force in a length of pipe due to its
thermal expansion that T.C. 6.1 found. These are: ASHRAE Handbooks Guided Cantilever Method and
U-bend equation, Handbook of Mechanical Engineering Calculations Grinnell-Spielvogel method,
Kelloggs Design of Piping Systems method, and a simple cantilevered beam undergoing free-end
deflection. The results of these equations were compared and graphed in response to an inquiry that
noticed discrepancies between Guided Cantilever Method and a simple cantilevered beam for anchor
force calculation. While researching the discrepancy between the two method in Sean Robinson expanded
his research to include the Grinnell-Spielvogel and the Kelloggs Design of Piping Systems to determine
if there was any agreement between the methods. Research found the existence of several software
programs such as CAESAR II, AutoPIPE, and CAEPIPE. Also there is a concern that the methods used
are out of date and used less.
This project is a continuation of the work started by Sean Robinson in the paper Comparison of
Simplified Computational Methods of Flexibility Analysis to Determine Thermally Developed U-Bend
and L-bend Anchor Forces. Computer modeling was not included in the paper because of financial and
time constraints. Plus one of the comments from a reviewer was the suggestion to run problem using
computer software.
Advancement to the State-of-the-Art:
First, the additional research would determine if the Guided Cantilever Method in the ASHRAE
Handbook should be deleted because it is too conservative and replaced with the simple cantilevered
calculation. Second, the U-Bend formula should be evaluated and replaced as the current formula in the
Handbook is a constant slope with respect to diameter whereas the Grinnell-Spielvogel and the Kelloggs
Design of Piping Systems methods display an exponential component that begins to deviate from the
linear slope round 12 inch diameter pipe. Third The Z-bend equation should be similarly evaluated for
validity and reliability
Justification and Value to ASHRAE:
ASHRAE strives for the most accurate, professional, informative, reliable, and up-to-date handbook
series on piping design. Including the new formulas in the Fundamental Handbook will modernize the
section on anchor forces.
Objectives:
Provide the Fundament Handbook user with a reliable, cost effective, easy to use equations to determine
anchor forces for small system. Larger systems should use computerize modeling to determine anchor
forces.
Key References:
2
American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc. (2010),Comparison of
Simplified Computational Methods of Flexibility Analysis to Determine Thermally Developed U-Bend
and L-bend Anchor Forces, Sean Robinson, ASHRAE
American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (2008). 2008 ASHRAE
Handbook. Atlanta, Georgia, USA.
Avallone, E. A., & Baumeister III, T. (Eds.). (1986). Mark's Standard Handbook for Mechanical
Engineers (7th ed.). New York: McGraw-Hill.
Azeem, H. (2001, September 10). Stress Analysis for Process Piping. Retrieved June 15, 2010, from J-
Tech Pvt. Ltd.: www.pipingdesign.com/stressanalysis.pdf
Basavaraju, C., & Sun, W. S. (n.d.). Stress Analysis of Piping Systems. Retrieved June 15, 2010, from
www.cadfamily.com/Download.asp?ID=280970
Becht Engineering Company. (2006, March 10). B31.3 Process Piping Workshop Supplement. Retrieved
June 15, 2010, from http://www.psig.sg/Don/B31.3%20Process%20Piping%20Course%20-
%20Supplement.pdf
National Oilwell Varco. (2010, January). Engineering & Piping Design Guide: Fiberglass Reinforced
Piping Systems. Retrieved June 15, 2010, from Fiber Glass Systems:
www.smithfibercast.com/pdf/E5000.pdf
Peng, L. C. (n.d.). Quick Check on Piping Flexibility. Retrieved June 15th, 2010, from Peng Engineering:
www.pipestress.com/papers/QuickFlex.pdf
Wu, M. C. (1997, January 19). Mechanical Structures. Retrieved June 15, 2010, from Electrical
Engineering UCLA: www.ee.ucla.edu/~wu/ee250b/Mechanical%20Structures.pdf