Sei sulla pagina 1di 2

Standard

How It Works
Comfort Vane
This1option conveniently
Convenient
How
How sets an ACs louvers to a preset position so that outowing air is directed away from a rooms occupants.
ItControl
It
Works
Works

Comfort Air Remote Control


Enjoy utmost comfort
ThisThis
option
Comfort
option
Comfort
in
Vane
Vane
just one
conveniently
conveniently anclick.
setssetsACs
an ACs
louvers
louvers
Scene
to Click
atopresetthe1:position
a preset
Inclines
button
position so that
so that
to
once a: maximum
outowing
outowing
air isairdirected
70
is directed
awayaway
angle.
fromfrom
a rooms Click
a rooms
the vane goes to the highest position for indirect airflow.
the buttonScene
occupants.
occupants. twice 2:
: Declines to a maximum 0 ang
the vane goes to the lowest position for indirect airflow.
(Optimized airflow forato
cooling) (Optimized airflow foraheating)
The comfort vane option conveniently Remote
Remote
Control
Control Scene
Scene
1: Inclines
1: Inclines
to maximum
a maximum
7070
angle.
angle. Scene
Scene
2: Declines
2: Declines
to ato
maximum
maximum0 angle.
0 angle.

sets the louvers to a preset position


that deflects the supply air away
from blowing directly onto room
occupants.

Sets Sets
vanevane
angleangle
to highest
to highest
position.
position. Sets Sets
vanevane
angleangle
to lowest
to lowest
position.
position.
Cooling
Cooling
& heating
& heating
without
without
uncomfortable
uncomfortable
airow.
airow. Cooling
Cooling
& heating
& heating
without
without
uncomfortable
uncomfortable
airow.
airow.
Sets
Optimized
Optimized
vaneforangle
gentle
for gentle
airow
to airow
cooling.
highest cooling.
position. Optimized
Optimized
for gentle
for gentle
airow Sets
airow
heating.
heating.
vane angle to lowest position.
Cooling & heating without uncomfortable airow. Cooling & heating without uncomfortable airow.
Optimized for gentle airow cooling. Optimized for gentle airow heating.

Benet
Benet
or
ause
cause How It Works 1 One Click
Convenient
Convenient
"Jet Control
Control
Mode"
cupants.
ants.
Enjoy
Enjoy
utmost
utmost
comfort
comfort
in just
in just
oneone
click.click.
comfort.
fort.
One Click Jet Mode Benet
GetReduces
Cool Quickly
the temperature of outowing air to 18C
Reduces the temperature of outflowing air to 18C for 30 minutes with just one click.

ConvenientPrevents
Control
Prevents
sudden
Cool
Cool
sudden
andand
drops
drops
Healthy
Healthy
in body
AirAir
in body
temperature.
temperature.
for 30 minutes with just one click.
"Jet cool" makes your air conditioner
Enjoy utmost comfort in just one click.
1Click
cool in a short period time. Cool and Healthy Air
18C
Prevents sudden drops in body temperature.
Benet
Benet
Easy to Open Easy to Clean
Easy to Open Easy to Clean
Removing the dust lter on a conventional air conditioner takes two steps, The lter is designed for easy h
but aRemoving the dustFilter
Dual Protection ltercan
on abeconventional
removed inair
oneconditioner
easy step.takes two steps, The lter is designed for easy ha
but a Dual Protection Filter can be removed in one easy step.

11Step
Step
Detachable
Ez
Ez
Cleaning
Detachable Cleaning
Grille Filter
Filter
Grille

1 What is the Dual Protection Filter? 2 Test Result & Certificate


Defense Dust
Test Result &
& Certicate The Dual Protection Filter, designed to capture dust particles
Bacteria Removal Test

Bacteria over 10m in size, is the first line of defense against finer
particles and bacteria.
Test
Dual
from
Result
Test Result
Protection
the Removal
&&Certicate
airRemoval
Bacteria
Bacteria
Certicate
Filter
in 18Test
eliminates up to 99.9% of bacteria
hours.
Test Ce
Test Result What isWhat is theProtection
the Dual Dual Protection
Filter?Filter? Dual Dual Protection
Protection FilterFilter eliminates
eliminates up99.9%
up to to 99.9% of bacteria
of bacteria from
from thethe
airair
in in
1818hours.
hours. Fiti
Fit

The Dual*: Test


Protection TheFilter
Dual Protectioncollects
The Dual Protection Filter, designed to capture dust particles over
Survival Rate Bacteria

Filter, designed to capture dust particles over


Temp.

Conditions * Test Conditions


Survival Rate Bacteria

100 100
Time(m)

10m 10m in size, is the rst line of defense against ner particles and bacteria.
in size, is temperature
the rst line of defense
Indoor temperature 33C, Outdoor 35C,against nerhumidity
Relative particles and
60%,bacteria.
Setting temperature 24C : Indoor temperature 33C, Outdoor temperature 35C, Relative humidity 60%, Setting temperature 24C
dust and bacteria from various other 75
75

sources. 33.00 50
18 hours.
18 hours.
99.9 %
50
99.9 %
Sterilization
Sterilization
25
10
12m30s
41
25

% Dust over 10m


Dust over 10m Bacteria
Bacteria 31.00
0 18 Time(hours)
Faster 0 18 Time(hours)

29.00 Fast
Cooling Conventional

5 7m20s 27.00
41% Dual Cool
SPECIFICATIONS LG Residential Air Conditioners 2016

9K

Standard E09EM
12K
E12EM

18K
E18EM

Optional

Jet Cool 2 Way Fast Dual Auto Comfort Quick Wi-Fi


Swing Heating Protection Cleaning Air & Easy Ready
Filter Installation

Unit 9K 12K 18K


Model Indoor Unit USNW096W4A1 USNW126H4A1 USNW186M4A1
Model Outdoor Unit USUW096W4A1 USUW126H4A1 USUW186M4A1
Indoor Unit
Capacity Cooling Min/Rated/Max W 890/2500/3700 900/3500/4040 900/5000/5400
Heating +7C Min/Rated/Max W 890/3200/4100 890/3800/5100 900/5400/6100
Heating -7C Rated W 3000 3600 3800
Power Input Cooling Rated W 730 1,120 1720
Heating +7C Rated W 950 1,040 1540
EER W/W 3.42 3.13 2.91
S.E.E.R. 5.7 5.8 5.3
P design C kW 2.5 3.5 5.0
COP W/W 3.37 3.65 3.51
S.C.O.P. 3.8 3.8 3.8
P design H kW 2.3 3.2 3.8
Energy Label Cooling A+ A+ A
Heating A A A
Annual Energy Consumption Cooling kWh 154 211 330
Heating kWh 847 1400 1400
Sound Pressure Cooling S/L/M/H dBA 20/25/33/39 20/25/33/39 29/35/40/42
Heating L/M/H dBA 28/33/39 28/33/39 35/40/42
Sound Power Cooling High dBA 58 58 60
Air Flow Rate Cooling S/L/M/H m/min 3.0 /4.5 /6.0 /7.5 3.5/5.5/8.0 /10.0 7.5/9.0/10.5/12.0
Max (Power) m/min 9.0 12.0 17.4
Heating L/M/H m/min 5.0 /6.0 /8.0 6.5/8.0 /10.0 8.0 /10.0/13.0
Dehumidification Rate l/h 0.83 1.3 1.8
Running Current Cooling Rated/Max A 3.2 /6.5 4.9/6.5 7.8/9.0
Heating Rated/Max A 4.2/6.0 4.6/6.0 7.0/9.5
Starting Current Cooling Rated A 3.2 4.9 7.8
Heating Rated A 4.2 4.6 7.0
Power Supply / V /Hz 1 / 220-240 / 50 1 / 220-240 / 50 1/220-240 / 50
Circuit Breaker A 15 15 20
Power Supply Cable N x mm 3*1.0 3*1.0 3*1.5
Power & Transmission Cable N x mm 4*0.75 (Including Earth) 4*0.75 (Including Earth) 4*0.75 (Including Earth)
Dimension mm 756*265*184 798*292*214 885 * 296 * 236
Net Weight kg 7.4 8.5 9.5
Fan Motor Output W 30 30 30
Outdoor Unit
Operation Range Cooling Min~Max CDB -10~48 -10~48 -10~48
Heating Min~Max CDB -10~24 -10~24 -10~24
Sound Pressure Cooling High dBA 49 49 52
Heating High dBA 49 49 54
Sound Power Cooling High dBA 65 65 65
Air Flow Rate High m/min 27 27 32
Piping Length (Odu/Idu) Min m 3 3 -
Max m 15 15 20
Elevation (Odu/Idu) Max m 7 7 10
Piping Connection Liquid OD(Outside) mm 6.35 6.35 6.35
OD(Outside) inch (1/4) (1/4) (1/4)
Gas OD(Outside) mm 9.52 9.52 12.7
OD(Outside) inch (3/8) (3/8) (1/2)
Drain OD(Outside) mm 21.5 21.5 21.5
OD(Outside) inch 0.85 0.85 0.85
Refrigerant Type R410A R410A R410A
Charge at 7.5m g 920 970 1,060
Additional charge g/m 20 20 20
Fan Motor Output W 43 43 43
Compressor Type Rotary Rotary Rotary
Net Weight kg 28 28 34
Dimension mm 717*483*230 717*483*230 770*545*288

* S : Sleep / L : Low / M : Medium / H : High


** Specification, design and feature are subject to change without prior notice.
*** This product contains Fluorinated greenhouse gases (R410A).

Potrebbero piacerti anche