WATER INJECTION CASE HISTORY

PROJECT OVERVIEW

Location : Algeria
Injection Rate : 40,000 50,000 bbl / day
Injection Pressure : 1,500 2,000 psi
Fluid : Aquifer water from feed well

EQUIPMENT USED:

Filtration : 2 off duplex cartridge filter units capable of


filtering 50,000 bbl / day down to 2 micron.

Chemical Injection : 1 x Multi pump (3 units) chemical injection skid


complete with day tanks
1 x single pump with day tank for biocide

Suction Booster Pump : Diesel driven 4 stage centrifugal pump,


boosting aquifer feed water from 100 psi up to
700 psi

Main Injection pump : Diesel driven 7 stage centrifugal pump skid

Well Head Filtration : High pressure (3,000psi) filter skids


used on additional injection wells

Ancillary Items : Diesel driven portable lighting towers


Low pressure flexible suction hoses / fittings
High pressure discharge line / fittings
20,000 gal bulk diesel storage tanks
2 x 40 ft stores containers
1 x 40 ft stores / workshop container
1 x 20 site office

PRODUCTS SUPPLIED

Filter cartridges : 10 micron nominal cartridges

Injection chemicals : Biocide


Scale Inhibitor
Oxygen Scavenger
Corrosion Inhibitor
PROJECT DETAILS

The main purpose for BJ providing the temporary injection package was due to
the delays the client was experiencing during the construction of their permanent
injection facility. This delay was causing problems with production and the
decision was made to install a temporary injection package.

BJ Services were initially contracted to supply a stand-alone water injection


package capable of injecting water into three wells simultaneously via an
injection pipeline loop with water supplied from an aquifer feed well.

The initial injection parameters were, 40,000 bbl / day @ 1,500 psi for a period of
six (6) months. The contract also included the supply of all injection chemicals,
these were provided by BJ Chemical Services, Houston.

Prior to commencing injection, the pipeline loop had to cleaned to remove all
rust, scale and debris.

Following the initial injection phase the client installed flow lines to two additional
injection wells. As these lines could not be cleaned online, BJ were ask to
provide additional high pressure filtration skids to remove any debris, rust and
scale from the new injection pipe-work.

The injection parameters were then changed to approximately 50,000 bbl / day at
2,000 psi. Maximum injection rate achieved during operations was 56,000 bbl /
day at 2,000 psi

After the initial six months, the client requested an extension to the contract as
further delays in the completion of their permanent facilities had been confirmed.

BJ continued the injection operations for a total period of eighteen months until
the clients permanent facilities had been commissioned.

The success of this temporary injection package provided by BJ Services was


evident in the revenues the client earned through the ability to attain early
production and also provide immediate pressure management to the producing
reservoir.
4 STAGE SUCTION BOOSTER CENTRIFUGAL PUMP

MULTISTAGE MAIN INJECTION CENTRIFUGAL PUMP SKID


7 STAGE MAIN INJECTION CENTRIFUGAL PUMP END

DUPLEX CARTRIDGE FILTER SKIDS


MULTI PUMP CHEMICAL INJECTION SKID WITH DAY TANKS AND
INJECTION MANIFOLD

8,000 GAL DIESEL STORAGE TANK


STORES / WORKSHOP CONTAINERS