Sei sulla pagina 1di 2

quick-chill and hold

cold control

TECHNICAL DATA
Housing: black ABS plastic, self-extinguish-
ing.
Dimensions: front 72x215.5 mm
(2.84x8.5), depth 110 mm (4.33).
Mounting: flush panel mount with two
mounting studs provided.
Connections: Faston connectors 6.3 mm
(1/4" male spade).
Display: 12.5 mm LED (0.50").
Push buttons: located on front panel.
Data storage: non-volatile EEPROM memo-
ry.
Operating temperature: 565 C
(23149 F).
Storage temperature: 3075 C
(22167 F).
fan Relay outputs: one (1) SPST relay 15(7)A
output
250V AC for compressor, one (1) SPDT
alarm relay 8(3)A 250V AC for defrost, two (2)
output SPST relays 8(3)A 250V AC for evaporator
fan control and light.
Remote alarm output: one (1) output
12 Vdc/50 mA to remote alarm buzzer or
relay.
Analog inputs: two (2) PTC probes for tem-
perature control and defrost termination,
one (1) insert probe for product control.
Digital inputs: four (4) digital inputs for door
switch, insert probe in parking, compres-
sor alarm and fan alarm.
Resolution: 1 C (F).
Accuracy: better than 0.5% of full scale.
Power supply (depending on model):
12 Vdc 15%; 12, 24, 110, 220 Vac
10%, 50/60 Hz.

EWFC 1000

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

room defrost door alarm insert comp. probe fans comp. fans defrost light
probe probe switch probe alarm holder alarm
switch switch switch

POWER SUPPLY

74
quick-chill and hold
cold control, open version

TECHNICAL DATA
Dimensions: front 56x202 mm (vertical
version); 202x56 mm (horizontal version).
Mounting: open version.
Connections: Faston connectors 6.3 mm
(1/4" male spade).
Display: 12.5 mm LED (0.50").
Push buttons: located on front panel.
Data storage: non-volatile EEPROM memo-
ry.
Operating temperature: 565 C
(23149 F). fan
Storage temperature: 3075 C output
(22167 F).
alarm
Relay outputs: one (1) SPST relay 15(7)A output
250V AC for compressor, one (1) SPDT
relay 8(3)A 250V AC for defrost, two (2)
SPST relays 8(3)A 250V AC for evaporator
fan control and light.
Remote alarm output: one (1) output
12 Vdc/50 mA to remote alarm buzzer or
relay.
Analog inputs: two (2) PTC probes for tem-
perature control and defrost termination,
one (1) insert probe for product control.
Digital inputs: three (3) digital inputs for
door switch, compressor alarm and fan
alarm.
Resolution: 1 C (F).
Accuracy: better than 0.5% of full scale.
Power supply (depending on model):
12 Vdc 15%; 12, 24, 110, 220 Vac
10%, 50/60 Hz.

POWER SUPPLY
neutral

phase

defrost fans light compressor

15 13 14 11 33 32 31 12 10 9 8 7 6 5 4 3 2 1

fans

defrost

light compressor

EWFC 1005

+ 28 27 26 25 24 23 45 44 22 21 20 19
to the
REMOTE KEYBOARD
+

75
alarm comp. fans door insert defrost room
output alarm alarm switch probe probe probe
switch switch

Potrebbero piacerti anche