Sei sulla pagina 1di 1

A3

TYPE COLUMN SCHEDULE NO

C1 230 X 230mm 16

C2 230 X 700mm 2

C3 230 X 230mm 8
8820
1 1600
2 1527 3123
3 2100
4 2400
5 3600
5' 6' 4200
6 5200
7
C5 230 X 230mm 4
3
L16

C1
3
250x1200 BEAM 01 C1 250x1200 BEAM 02 C1 L17
C1
A

1424
A'
1804

3 C3 C3

610
250x1200 BEAM 03 C5
250/600mm-1200mm(varying depth) BEAM 04 L16

250 1200 BEAM 24


600 B

250x1200 BEAM 19

250x1200 BEAM 21
250x1200 BEAM 15

250x1200 BEAM 22
600

250x1200 BEAM 26

3300
600 600 600
230X600 BEAM 14

600
3
L17
C3 C3 C3
250x1200 BEAM 02 250x1050 BEAM 05 C5
5600

C1 C1 C
2 2 4 4
L17 L17 L16 L16
450

3000
1655
600
C1 C1 C1 250x1200/1050 BEAM 06 C1 C3
250/600mm-1200mm(varying depth) BEAM 04 D

250x1200 BEAM 16

250X1050 BEAM 28
250x1200 BEAM 25

250x1200 BEAM 27
1 1
2 600 2 L17 L17
2555

L16 L16 600 600

3515
450
C3 250x1200 BEAM 07 C1
C1
600 C3

960
1025 C5
1400

1. ALL GROUND SLAB PANELS ARE 250mm THCK UNLESS OTHERWISE STATED 250x1200/1050 BEAM 08

330
250x1200 BEAM 09
250x1200 BEAM 18
450

250x1200 BEAM 20
2. EXISTING LEVEL OF SITE TO BE RAISED BY 1000mm TO ENHANCE SOIL
C2 600

1885
BEARING CAPACITY. SHARP SAND FILL MATERIALS TO BE COMPACTED IN 600 600 600
LAYERS NOT EXCEEDING 150mm THK. BY THE USE OF OF A MINIMUM 250X1050 BEAM 10 C5
2645

10-TONNE VIBRATORY ROLLER MACHINE.


E

1200
250x1200 BEAM 23
250x1200 BEAM 17

3. COMPACTION EXERCISE TO BE UNDERTAKEN UNDER THE SUPERVISION C1 C3 250x1200 BEAM 12 C3


C2
OF THE STRUCTURAL ENGINNEER.
250x1200 BEAM 11
F
1400

4. PLATE LOAD POST-COMPACTION TEST SHALL BE CARRIED OUT TO 1 1


DETERMINE POST COMPACTION PARAMETERS OF THE FILLED AREA. 250x1200 BEAM 13 L16 L16
NO. OF TEST POINTS TO BE CARRIED OUT BY THE STRUCTURAL ENGINEER. C1 C1 C1 G
460 2720 3570 2400 2415 5385

Sanni, Ojo & Partners Consulting Limited


NOTES: Drawing Title
NOTES APPLICABLE TO THIS DRAWING
L1228/-/G/01
Job Title 1. George Alade Lane, off Fola Agoro Street,
Abule Ijesha, Somolu, Lagos, Nigeria.
1. SEE GENERAL NOTES ON DRAWING NO. ................... The Contractor is to check all drawings P.O.Box 150, Yaba, Lagos, Nigeria
2. REINF. LISTED ON BENDING SCHEDULE/S PAGES.........
before starting work and any discrepancies EKULO INTERNATIONAL LIMITED MAIN BUILDING Tel. nos: +234(0)8078192410
Email: sop@sop-consulting.com
3. DRAWING DONE ORIGINALLY ON THE PAPER SIZE found on this drawing or between this drawing Website: www.sop-consulting.com
INDICATED ON THE TOP LEFT CORNER
and any other drawing issued by any party By
are to be brought to the notice of the
RESIDENTIAL BUILDING DEVELOPMENT AT GROUND FLOOR/FOUNDATION LAYOUT Scales
Description Date
Drawn NJE 13-12-2016
Engineers immediately. Indicated dimensions are
ZONE B,ROAD B6, PLOT 91, NICON TOWN 1 : 125 Checked: EOI 13-12-2066
in mm unless otherwise stated. Dimensions are Mark Date by Revision LEKKI, LAGOS STATE. Approved LOK 13-12-2016
to be confirmed on site. Drawing Status Job No: Revision

FOR PLANNING APPROVAL L1228 MB L 10 P