JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD
IV B.Tech. I Sem., I Mid-Term Examinations, September - 2017
MEDICAL INSTRUMENTATION
Objective Exam
Name: ______________________________ Hall Ticket No. A
Answer All Questions. All Questions Carry Equal Marks. Time: 20 Min. Marks: 10.
6. An electrically excitable cell that processes and transmits information through electrical and
chemical signals. [ ]
a) Neuron b) Nephron c) Erythrocyte d) Dendrite
7. In electroretinogram, __________ wave is derived from the rods and cones of the retina. [ ]
a) A b) B c) C d) D
8. _________ electrodes are those in which current passes freely across the electrode-electrolyte
interface, requiring no energy to make the transition. [ ]
a) Polarized b) Nonpolarized c) Both (a) & (c) d) None of the above
9. Chopper input dc amplifiers are preferred for low level inputs to instrumentation systems because of
___________. [ ]
a) High sensitivity b) Negligible drift
c) Excellent common mode rejection capability d) All the above
Cont..2
Code No: 117BA :2: Set No. 1
11. The range of internal resting potential within a cell with reference to the outside of the cell is
_____________.
14. To study the electrical activity of individual cells, ______________ electrodes are employed.
16. An _______________ is a long, slender projection of a nerve cell, or neuron, that typically conducts
electrical impulses away from the neuron's cell body.
19. The technique of measurement of speed of conduction of impulses down a peripheral nerve is
______________.
20. In the nervous system, a __________ is a structure that permits a neuron to pass an electrical or
chemical signal to another neuron.
-oOo-
Code No: 117BA Set No. 2
JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD
IV B.Tech. I Sem., I Mid-Term Examinations, September - 2017
MEDICAL INSTRUMENTATION
Objective Exam
Name: ______________________________ Hall Ticket No. A
Answer All Questions. All Questions Carry Equal Marks. Time: 20 Min. Marks: 10.
3. An electrically excitable cell that processes and transmits information through electrical and
chemical signals. [ ]
a) Neuron b) Nephron c) Erythrocyte d) Dendrite
4. In electroretinogram, __________ wave is derived from the rods and cones of the retina. [ ]
a) A b) B c) C d) D
5. _________ electrodes are those in which current passes freely across the electrode-electrolyte
interface, requiring no energy to make the transition. [ ]
a) Polarized b) Nonpolarized c) Both (a) & (c) d) None of the above
6. Chopper input dc amplifiers are preferred for low level inputs to instrumentation systems because of
___________. [ ]
a) High sensitivity b) Negligible drift
c) Excellent common mode rejection capability d) All the above
10. The state of alertness of the brain is represented by _____ rhythm of EEG. [ ]
a) Alpha b) Beta c) Delta d) Theta
Cont..2
Code No: 117BA :2: Set No. 2
11. To study the electrical activity of individual cells, ______________ electrodes are employed.
13. An _______________ is a long, slender projection of a nerve cell, or neuron, that typically conducts
electrical impulses away from the neuron's cell body.
16. The technique of measurement of speed of conduction of impulses down a peripheral nerve is
______________.
17. In the nervous system, a __________ is a structure that permits a neuron to pass an electrical or
chemical signal to another neuron.
18. The range of internal resting potential within a cell with reference to the outside of the cell is
_____________.
-oOo-
Code No: 117BA Set No. 3
JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD
IV B.Tech. I Sem., I Mid-Term Examinations, September - 2017
MEDICAL INSTRUMENTATION
Objective Exam
Name: ______________________________ Hall Ticket No. A
Answer All Questions. All Questions Carry Equal Marks. Time: 20 Min. Marks: 10.
1. An electrically excitable cell that processes and transmits information through electrical and
chemical signals. [ ]
a) Neuron b) Nephron c) Erythrocyte d) Dendrite
2. In electroretinogram, __________ wave is derived from the rods and cones of the retina. [ ]
a) A b) B c) C d) D
3. _________ electrodes are those in which current passes freely across the electrode-electrolyte
interface, requiring no energy to make the transition. [ ]
a) Polarized b) Nonpolarized c) Both (a) & (c) d) None of the above
4. Chopper input dc amplifiers are preferred for low level inputs to instrumentation systems because of
___________. [ ]
a) High sensitivity b) Negligible drift
c) Excellent common mode rejection capability d) All the above
Cont..2
Code No:117BA :2: Set No. 3
11. An _______________ is a long, slender projection of a nerve cell, or neuron, that typically conducts
electrical impulses away from the neuron's cell body.
14. The technique of measurement of speed of conduction of impulses down a peripheral nerve is
______________.
15. In the nervous system, a __________ is a structure that permits a neuron to pass an electrical or
chemical signal to another neuron.
16. The range of internal resting potential within a cell with reference to the outside of the cell is
_____________.
19. To study the electrical activity of individual cells, ______________ electrodes are employed.
-oOo-
Code No: 117BA Set No. 4
JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD
IV B.Tech. I Sem., I Mid-Term Examinations, September - 2017
MEDICAL INSTRUMENTATION
Objective Exam
Name: ______________________________ Hall Ticket No. A
Answer All Questions. All Questions Carry Equal Marks. Time: 20 Min. Marks: 10.
1. _________ electrodes are those in which current passes freely across the electrode-electrolyte
interface, requiring no energy to make the transition. [ ]
a) Polarized b) Nonpolarized c) Both (a) & (c) d) None of the above
2. Chopper input dc amplifiers are preferred for low level inputs to instrumentation systems because of
___________. [ ]
a) High sensitivity b) Negligible drift
c) Excellent common mode rejection capability d) All the above
9. An electrically excitable cell that processes and transmits information through electrical and
chemical signals. [ ]
a) Neuron b) Nephron c) Erythrocyte d) Dendrite
10. In electroretinogram, __________ wave is derived from the rods and cones of the retina. [ ]
a) A b) B c) C d) D
Cont..2
Code No:117BA :2: Set No. 4
12. The technique of measurement of speed of conduction of impulses down a peripheral nerve is
______________.
13. In the nervous system, a __________ is a structure that permits a neuron to pass an electrical or
chemical signal to another neuron.
14. The range of internal resting potential within a cell with reference to the outside of the cell is
_____________.
17. To study the electrical activity of individual cells, ______________ electrodes are employed.
19. An _______________ is a long, slender projection of a nerve cell, or neuron, that typically conducts
electrical impulses away from the neuron's cell body.