No Rev Page
1000 PROC DT 1212 1 1 de 13
APPROVED/
REV. DATE DESCRIPTION PREPARED CHECKED
AUTHORIZED
DOCUMENT REVIEW
Proj.Id Unit Dept. Ctgry. Seq.No Rev Page
1000 PROC DT 1212 1 2 de 13
REVISION HISTORY
F-301 / 302A/B / 101 / 102A/B / 205 / 206A/B / 401 / 402 are added in the datasheet
2 of 13
Proj.Id Unit Dept. Ctgry. Seq.No Rev Page
1000 PROC DT 1212 1 3 de 13
Rev ITEM
2
FILTER & AIR ELIMINATOR
3
F-301 PROCESS DATA SHEET
4
14 Fluid Properties
15 Fluid Gasoil
16 Fluid Phase Liquid
17 Flammable/Explosive Yes
18 Corrosive No
19 Density @ Op. kg/m3 860
20 Viscosity @ Op. / maximum cP 8.2
21
22 Operating Conditions
23 Flow Rate (max) m3/h 360
24 Inlet Temperature C 20-40
25 Minimum Ambient Temperature C 0
26 Inlet Pressure bar-g 4.4
27
28 Design Data
29 Filter type (4)
30 Duty Intermittent
31 Mechanical Design Temperature C (2) 80
32 Mechanical Design Pressure bar-g 18.3
33 Maximum Pressure Drop (admitted with a dirty basket) bar (3) 1.5
34 Design Capacity m3/h 360
35 Materials of Construction Body CS
36 Filter Element By Vendor
37
38 NOTES
39 (1) The combination of Strainer cum Air Eliminator for removal of solid impurities,air or vapour from the liquid,
40 before they enter the flow metre.
41
(2) Solar radiation temperature
42
(3) Maximum allowable Pressure drop. Vendor to provide the required minimum.
43 (4) Strainer basket with wire mesh filter element.
44
3 of 13
Proj.Id Unit Dept. Ctgry. Seq.No Rev Page
1000 PROC DT 1212 1 4 de 13
Rev ITEM
2
FILTER & AIR ELIMINATOR
3
F-302 A/B PROCESS DATA SHEET
4
14 Fluid Properties
15 Fluid Gasoil
16 Fluid Phase Liquid
17 Flammable/Explosive Yes
18 Corrosive No
19 Density @ Op. kg/m3 860
20 Viscosity @ Op. / maximum cP 8.2
21
22 Operating Conditions
23 Flow Rate (max) m3/h 100
24 Inlet Temperature C 20-40
25 Minimum Ambient Temperature C 0
26 Inlet Pressure bar-g 4.03
27
28 Design Data
29 Filter type (4)
30 Duty Intermittent
31 Mechanical Design Temperature C (2) 80
32 Mechanical Design Pressure bar-g 18.3
33 Maximum Pressure Drop bar (3) 1.5
34 Design Capacity m3/h 100
35 Materials of Construction Body CS
36 Filter Element By Vendor
37
38 NOTES
39 (1) The combination of Strainer cum Air Eliminator for removal of solid impurities,air or vapour from the liquid,
40 before they enter the flow metre.
41
(2) Solar radiation temperature
42
(3) Maximum allowable Pressure drop. Vendor to provide the required minimum.
43 (4) Strainer basket with wire mesh filter element.
44
4 of 13
Proj.Id Unit Dept. Ctgry. Seq.No Rev Page
1000 PROC DT 1212 1 5 de 13
2
Rev ITEM
3 FILTER & AIR ELIMINATOR
4
F-101 PROCESS DATA SHEET
5
23 Operating Conditions
24 Flow Rate (max) m3/h 360
25 Inlet Temperature C 20-40
26 Minimum Ambient Temperature C 0
27 Inlet Pressure bar-g 3.93
28
29 Design Data
30 Filter type (4)
31 Duty Intermittent
32 Mechanical Design Temperature C (2) 80
33 Mechanical Design Pressure bar-g 18.3
34 Maximum Pressure Drop bar (3) 1.5
35 Design Capacity m3/h 360
36 Materials of Construction Body CS
37
Filter Element By Vendor
38
39 NOTES
40 (1) The combination of Strainer cum Air Eliminator for removal of solid impurities,air or vapour from the liquid,
41 before they enter the flow metre.
42 (2) Solar radiation temperature
43 (3) Maximum allowable Pressure drop. Vendor to provide the required minimum.
44 (4) Strainer basket with wire mesh filter element.
5 of 13
Proj.Id Unit Dept. Ctgry. Seq.No Rev Page
1000 PROC DT 1212 1 6 de 13
Rev ITEM
2
FILTER & AIR ELIMINATOR
3
F-102 A/B PROCESS DATA SHEET
4
14 Fluid Properties
15 Fluid Gasoline
16 Fluid Phase Liquid
17 Flammable/Explosive Yes
18 Corrosive No
19 Density @ Op. kg/m3 780
20 Viscosity @ Op. / maximum cP 0.735
21
22 Operating Conditions
23 Flow Rate (max) m3/h 100
24 Inlet Temperature C 20-40
25 Minimum Ambient Temperature C 0
26 Inlet Pressure bar-g 3.25
27
28 Design Data
29 Filter type (4)
30 Duty Intermittent
31 Mechanical Design Temperature C (2) 80
32 Mechanical Design Pressure bar-g 18.3
33 Maximum Pressure Drop bar (3) 1.5
34 Design Capacity m3/h 100
35 Materials of Construction Body CS
36 Filter Element By Vendor
37
38 NOTES
39 (1) The combination of Strainer cum Air Eliminator for removal of solid impurities,air or vapour from the liquid,
40 before they enter the flow metre.
41
(2) Solar radiation temperature
42
(3) Maximum allowable Pressure drop. Vendor to provide the required minimum.
43 (4) Strainer basket with wire mesh filter element.
44
6 of 13
Proj.Id Unit Dept. Ctgry. Seq.No Rev Page
1000 PROC DT 1212 1 7 de 13
Rev ITEM
2
FILTER WATER SEPARATOR PACKAGE
3
F-202 A/B PROCESS DATA SHEET
4
14 Fluid Properties
15 Fluid Jet A1
16 Fluid Phase Liquid
17 Flammable/Explosive Yes
18 Corrosive No
19 Density @ Op. kg/m3 820
20 Viscosity @ Op. / maximum cP 0.2
21
22 Operating Conditions
23 Flow Rate (max) m3/h 60
24 Inlet Temperature C 20-40
25 Minimum Ambient Temperature C 0
26 2 Inlet Pressure bar-g 6.38
27 Fluid Inlet Specifications Hold
28 Fluid Outlet Specifications See Attachment 1
29 Design Data
30 Filter type (4)
31 Duty Intermittent
32 Mechanical Design Temperature C (2) 80
33 Mechanical Design Pressure bar-g 18.3
34 2 Maximum Pressure Drop bar (3) 0.7
35 Design Capacity m3/h 60
36 Materials of Construction Body CS
37 Filter Element By Vendor
38
39 NOTES
40 (1) The package shall include the filter caolescer, air eliminator, controls & instrumentation associated piping &
41 accesories meeting API/IP 1581 requiremnets
42
(2) Solar radiation temperature
43
(3) Maximum allowable Pressure drop. Vendor to provide the required minimum.
44
(4) According to API/IP 1581 5th edition.
45
7 of 13
Proj.Id Unit Dept. Ctgry. Seq.No Rev Page
1000 PROC DT 1212 1 8 de 13
Rev ITEM
2
FILTER & AIR ELIMINATOR
3
F-203 PROCESS DATA SHEET
4
14 Fluid Properties
15 Fluid Jet A1
16 Fluid Phase Liquid
17 Flammable/Explosive Yes
18 Corrosive No
19 Density @ Op. kg/m3 820
20 Viscosity @ Op. / maximum cP 0.2
21
22 Operating Conditions
23 Flow Rate (max) m3/h 200
24 Inlet Temperature C 20-40
25 Minimum Ambient Temperature C 0
26 2 Inlet Pressure bar-g 4.5
27
28 Design Data
29 Filter type (4)
30 Duty Intermittent
31 Mechanical Design Temperature C (2) 80
32 Mechanical Design Pressure bar-g 18.3
33 2 Maximum Pressure Drop bar (3) 1.5
34 Design Capacity m3/h 200
35 Materials of Construction Body CS
36 Filter Element By Vendor
37
38 NOTES
39 (1) The combination of Strainer cum Air Eliminator for removal of solid impurities,air or vapour from the liquid,
40 before they enter the flow metre.
41
(2) Solar radiation temperature
42
(3) Maximum allowable Pressure drop. Vendor to provide the required minimum.
43 (4) Strainer basket with wire mesh filter element.
44
8 of 13
Proj.Id Unit Dept. Ctgry. Seq.No Rev Page
1000 PROC DT 1212 1 9 de 13
Rev ITEM
2
FILTER & AIR ELIMINATOR
3
F-204 A/B PROCESS DATA SHEET
4
14 Fluid Properties
15 Fluid Jet A1
16 Fluid Phase Liquid
17 Flammable/Explosive Yes
18 Corrosive No
19 Density @ Op. kg/m3 820
20 Viscosity @ Op. / maximum cP 0.2
21
22 Operating Conditions
23 Flow Rate (max) m3/h 100
24 Inlet Temperature C 20-40
25 Minimum Ambient Temperature C 0
26 2 Inlet Pressure bar-g 3.67
27
28 Design Data
29 Filter type (4)
30 Duty Intermittent
31 Mechanical Design Temperature C (2) 80
32 Mechanical Design Pressure bar-g 18.3
33 2 Maximum Pressure Drop bar (3) 1.5
34 Design Capacity m3/h 100
35 Materials of Construction Body CS
36 Filter Element By Vendor
37
38 NOTES
39 (1) The combination of Strainer cum Air Eliminator for removal of solid impurities,air or vapour from the liquid,
40 before they enter the flow metre.
41
(2) Solar radiation temperature
42
(3) Maximum allowable Pressure drop. Vendor to provide the required minimum.
43 (4) Strainer basket with wire mesh filter element.
44
9 of 13
Proj.Id Unit Dept. Ctgry. Seq.No Rev Page
1000 PROC DT 1212 1 10 de 13
Rev ITEM
2
FILTER & AIR ELIMINATOR
3
F-205 PROCESS DATA SHEET
4
14 Fluid Properties
15 Fluid Kerosene
16 Fluid Phase Liquid
17 Flammable/Explosive Yes
18 Corrosive No
19 Density @ Op. kg/m3 820
20 Viscosity @ Op. / maximum cP 2.1
21
22 Operating Conditions
23 Flow Rate (max) m3/h 200
24 Inlet Temperature C 20-40
25 Minimum Ambient Temperature C 0
26 Inlet Pressure bar-g 3.36
27
28 Design Data
29 Filter type (4)
30 Duty Intermittent
31 Mechanical Design Temperature C (2) 80
32 Mechanical Design Pressure bar-g 18.3
33 Maximum Pressure Drop bar (3) 1.5
34 Design Capacity m3/h 200
35 Materials of Construction Body CS
36 Filter Element By Vendor
37
38 NOTES
39 (1) The combination of Strainer cum Air Eliminator for removal of solid impurities,air or vapour from the liquid,
40 before they enter the flow metre.
41
(2) Solar radiation temperature
42
(3) Maximum allowable Pressure drop. Vendor to provide the required minimum.
43
(4) Strainer basket with wire mesh filter element.
44
10 of 13
Proj.Id Unit Dept. Ctgry. Seq.No Rev Page
1000 PROC DT 1212 1 11 de 13
Rev ITEM
2
FILTER & AIR ELIMINATOR
3
F-206 A/B PROCESS DATA SHEET
4
14 Fluid Properties
15 Fluid Kerosene
16 Fluid Phase Liquid
17 Flammable/Explosive Yes
18 Corrosive No
19 Density @ Op. kg/m3 820
20 Viscosity @ Op. / maximum cP 2.1
21
22 Operating Conditions
23 Flow Rate (max) m3/h 200
24 Inlet Temperature C 20-40
25 Minimum Ambient Temperature C 0
26 Inlet Pressure bar-g 2.65
27
28 Design Data
29 Filter type (4)
30 Duty Intermittent
31 Mechanical Design Temperature C (2) 80
32 Mechanical Design Pressure bar-g 18.3
33 Maximum Pressure Drop bar (3) 1.5
34 Design Capacity m3/h 200
35 Materials of Construction Body CS
36 Filter Element By Vendor
37
38 NOTES
39 (1) The combination of Strainer cum Air Eliminator for removal of solid impurities,air or vapour from the liquid,
40 before they enter the flow metre.
41
(2) Solar radiation temperature
42
(3) Maximum allowable Pressure drop. Vendor to provide the required minimum.
43 (4) Strainer basket with wire mesh filter element.
44
11 of 13
Proj.Id Unit Dept. Ctgry. Seq.No Rev Page
1000 PROC DT 1212 1 12 de 13
Rev ITEM
2
FILTER & AIR ELIMINATOR
3
F-401 PROCESS DATA SHEET
4
14 Fluid Properties
15 Fluid Fuel oil
16 Fluid Phase Liquid
17 Flammable/Explosive Yes
18 Corrosive No
19 Density @ Op. kg/m3 980
20 Viscosity @ Op. / maximum cP 245
21
22 Operating Conditions
23 Flow Rate (max) m3/h 200
24 Inlet Temperature C 20-40
25 Minimum Ambient Temperature C 0
26 Inlet Pressure bar-g 5.51
27
28 Design Data
29 Filter type (4)
30 Duty Intermittent
31 Mechanical Design Temperature C (2) 80
32 Mechanical Design Pressure bar-g 18.3
33 Maximum Pressure Drop bar (3) 1.5
34 Design Capacity m3/h 200
35 Materials of Construction Body CS
36 Filter Element By Vendor
37
38 NOTES
39 (1) The combination of Strainer cum Air Eliminator for removal of solid impurities,air or vapour from the liquid,
40 before they enter the flow metre.
41
(2) Solar radiation temperature
42
(3) Maximum allowable Pressure drop. Vendor to provide the required minimum.
43 (4) Strainer basket with wire mesh filter element.
44
12 of 13
Proj.Id Unit Dept. Ctgry. Seq.No Rev Page
1000 PROC DT 1212 1 13 de 13
Rev ITEM
2
FILTER & AIR ELIMINATOR
3
F-402 PROCESS DATA SHEET
4
14 Fluid Properties
15 Fluid Fuel oil
16 Fluid Phase Liquid
17 Flammable/Explosive Yes
18 Corrosive No
19 Density @ Op. kg/m3 980
20 Viscosity @ Op. / maximum cP 245
21
22 Operating Conditions
23 Flow Rate (max) m3/h 100
24 Inlet Temperature C 20-40
25 Minimum Ambient Temperature C 0
26 Inlet Pressure bar-g 3.62
27
28 Design Data
29 Filter type (4)
30 Duty Intermittent
31 Mechanical Design Temperature C (2) 80
32 Mechanical Design Pressure bar-g 18.3
33 Maximum Pressure Drop bar (3) 1.5
34 Design Capacity m3/h 100
35 Materials of Construction Body CS
36 Filter Element By Vendor
37
38 NOTES
39 (1) The combination of Strainer cum Air Eliminator for removal of solid impurities,air or vapour from the liquid,
40 before they enter the flow metre.
41
(2) Solar radiation temperature
42
(3) Maximum allowable Pressure drop. Vendor to provide the required minimum.
43 (4) Strainer basket with wire mesh filter element.
44
13 of 13