Sei sulla pagina 1di 2

Nozzle Pressure

BIT NOZZLE(S) PRESSURE DROP


Nozzle Dia
Nozzle Numbers in Decimal Flow Area
in in2
Nozzle #1; ( X/32" ) = 18 0.56250 0.24850
Nozzle #2; ( /32" ) =
X
12 0.37500 0.11045
Nozzle #3; ( /32" ) =
X
12 0.37500 0.11045
Nozzle #4; ( /32" ) =
X
12 0.37500 0.11045
Nozzle #5; ( X/32" ) = 12 0.37500 0.11045
Nozzle #6; ( X/32" ) = 12 0.37500 0.11045
Nozzle #7; ( X/32" ) = 0 0.00000 0.00000
Nozzle #8; ( X/32" ) = 0 0.00000 0.00000
Total Flow Area A, in2 = 0.80074
Flow Rate Q; gpm = 755.00
Fluid Density (weight) W; ppg = 14.700
Pressure Drop D p, psi = 1,203.60
Drilex Operation HandBook, p.12

Enter Nozzle Sizes


Enter Flow Rate
Enter Fluid Density

Page 1
Pipe Pressure

PRESSURE DROP THROUGH PIPE


INPUT in Feet
Pipe id, in D 1 0.083 ft
Pipe Length, in L 45 3.750 ft
Flow rate, gpm Q 200 0.446 ft3/s
Density, slug/ft3 r 1.937
Viscosity, lbf.s/ft2 m 2.09E-05
Roughness factor e 8.50E-04
OUTPUT
Velocity V 8.170E+01 ft/s
Re number Re 6.304E+05
e/d e/d 1.020E-02
friction factor f 3.800E-02 <-from chart
Resistance coeff K 1.710E+00
Pressure Drop Dp 77 psi

1. Enter d, L, Q, r, m, e
2. Enter friction factor f based on Re and e/d
3. Read Pressure drop in cell D15
4. Mark's M.E. handbook

Page 2