Sei sulla pagina 1di 5

Over Head Water Tank Design

Height Width Length


5 ft 8.3 ft 18.4 ft
Calculation for bottom slab 18.42
Water Pressure at bottom 312 Psf
Minimum Thickness 3.6 in
Provided Thickness 4 in
Self Weight of the slab 50 Psf
Live Load 25 Psf
Wu 549.3 Psf
Moment From ACI moment coefficient
At midspan M+ 4764.42 fl-lb/ft
M- 3465.03 fl-lb/ft
Maximu ratio .016
dreq 2.61 in
Used d 3 in
Temp & Shrinkage Reinforcement .096 in2/ft
10 mm 10mm @ 13.8 in c/c
12 mm 12mm @ 25 in c/c
16 mm 16mm @ 38.8 in c/c
M+ 4.8 k-ft/ft .407 in2 M(k-ft) b(in
M- 3.5 k-ft/ft .283 in2 4.8 k-ft/ft 12
Check 10 in brick wall is ok or not
Find the moment from Grasp software a 0.80
Length 5 ft
Triangular loading 62.4 k-ft/ft As 0.41
Ixx 1000 in4 M(k-ft) b(in
Maxium Moment 37.4 k-ft 3.5 k-ft/ft 12
Stress 2.2 Psi
Stress 323.5 psf a 0.55
Stress canbe taken 400 psf
10 inch brick wall is ok As 0.28
Design of Cover Slab over the roof wall
Asumed value 3 in
Self Weight of the slab 37.5 Psf
Live load 25 Psf
Factored Load 95 psf/ft
Slab is one Way Follow the below procedure
One way slab of Width 8.3 ft Height 18.4 ft
M+ 823.99 fl-lb/ft
dreq .98 in
Slab thickness is ok
Use d 2 in
Temperature and Shriankage reinforcement .072 in2
M+ .8 k-ft/ft .096 in2 M(k-ft)
Slab load calculation .8 k-ft/ft
Self Weight of the slab 37.5 Psf
Weight of the water 312.5 Psf a
Live load 25 Psf
Total load 532.5 Psf As
For the short span 1.48 k/ft
For the long span 2.07 k/ft 0.4522258415
Beam Load Calculation
side wall thickness 4 in
Side wall weight 0.25
For the short span 1.73 k/ft
For the long span 2.32 k/ft
Long Side beam design
At support M- 65.5 k-ft
At midspan M+ 29.2 k-ft
Support Design
M(k-ft) b(in d (in) fc' fy
65.5 k-ft/ft 12 14 in 3 60 2.213712
.
a 2.21

As 1.13 in2
Mid section design
M(k-ft) b(in d (in) fc' fy
29.2 k-ft/ft 10 10 in 3 60 1.666574
.
a 1.67

As 0.71 in2
Short Side beam design
At support M- 10 k-ft
At midspan M+ 5 k-ft
Support Design
M(k-ft) b(in d (in) fc' fy
10 k-ft/ft 12 14 in 3 60 0.314625
.
a 0.31

As 0.16 in2
Mid section design
M(k-ft) b(in d (in) fc' fy
5 k-ft/ft 10 10 in 3 60 0.264822
.
a 0.26

As 0.11 in2
d (in) fc' fy
3 in 3 60 0.798182
.

in2
d (in) fc' fy
3 in 3 60 0.554521
.

in2

b(in d (in) fc' fy


12 2 in 3 60 0.188392
.
0.19

0.10 in2
No of apartments 15 Nos
Person per apartments 8 Nos
capacity need 497 cft (for 0.5 days for over head water tank)

Potrebbero piacerti anche