Sei sulla pagina 1di 36

Communications Systems | PRS-NCO3 Network Controller

PRS-NCO3 Network Controller


www.boschsecurity.com

u Public address and emergency sound system control


unit

u Control and routing of 28 simultaneous audio


channels

u Ethernet interface for configuration, control,


diagnostics, and logging

u Digital storage for prerecorded messages

u EN 5416 and ISO 724016 system certification

The network control unit is the heart of the Praesideo system actions, with freely programmable priorities.
system. The unit routes up to 28 simultaneous audio The line inputs provide selectable 20 kHz pilot tone
channels, delivers power to the system, reports faults, detection for cable supervision.
and controls the system. Audio inputs can be The controller has four analog audio line outputs each
announcements from call stations, background music, with a selectable 20 kHz monitoring signal. Three
or local audio. The network control unit can be control outputs are programmable for faults or calls,
configured for the most complex public address and two others are used to connect visual and audible
systems. The configuration can be done comfortably fault indicators.
and efficiently via a PC. The PC is only needed for A 24 Vdc auxiliary output is available that can be used
configuration. The controller can operate to power an external visual fault and/or emergency
independently of the PC. However, the controller can light tower.
use a PC to display information on the system status
Operation and performance
using the software, supplied with the unit. The unit
The network controller is completely configurable from
can be freestanding on a tabletop or mounted in a 19"
a PC using the supplied software, which can also
rack.
provide the current status of the running system, as
The PRSNCO3 network controller needs PRSSW
well as comfortable and efficient configuration. The
software version 4.0 or higher.
controller can also run without a connected PC, once
Functions it has been configured. The front panel has a
2 x 16character LCD display and a rotary control to
Connectivity navigate through the menu and select the menu items.
The network controller has four analog audio inputs. Address, version, fault events, and monitor enquiries
Of these, two are selectable between microphone and can be done using the display and control knob. The
line. The other two inputs are fixed as line inputs. The network controller can control up to 60 nodes. Nodes
microphone/line inputs can be used as call inputs, if include equipment such as power amplifiers, audio
they are programmed conditionally to any of the eight expander units, call stations, call station kits, etc.
control inputs, which are freely programmable for To meet the requirements for emergency sound
systems, automatic messaging is included in the
network controller. The controller has a built-in,
2 | PRS-NCO3 Network Controller

replaceable compact flash memory card, to match the Two system network connections
storage requirements for audio messages. Four 24 Vdc auxiliary output
messages can be played simultaneously. Message
Certifications and approvals
storage and the messages themselves are monitored.
Audio messages (as a set of wav files) can be
Safety acc. to IEC 60065 / EN 60065
downloaded from a computer via the Ethernet link.
The controller also stores a wide range of attention Immunity acc. to EN 551032 / EN 501304 /
tones, test tones, and alarm tones, all accessible by EN 501214
any call stations or control inputs for announcement or
Emissions acc. to EN 551031 / FCC47 part 15B
alarm broadcast. The network controller has a built-in
buzzer for notification of faults or emergency Emergency acc. to EN 60849 / EN 5416 /
situations. An internal real time clock allows for event ISO 724016
scheduling, such as playing scheduled announcements
Maritime acc. to IEC 60945
or changing the volume of background music during
evening hours. It has extensive audio processing
Region Certification
possibilities for the audio inputs and the audio
outputs. Parametric equalization, limiter and gain can Europe CPR EU_CPR
be easily adjusted using the configuration software.
CE DOC
There is a headset jack for monitoring the audio
channels. CE COC
Security CE CertAlarm
The network controller supports redundant network
CE COC
cabling. It can be wired as a branched network or
redundant loop. The system can handle 256 priorities, CE COC
for calls to hundreds of zones, satisfying even the CE DOP
most complex public address and emergency
requirements. TUEV-
SUED
The controller monitors the status of all the equipment
in the system, reports status changes, and stores the GL
last 200 fault messages in the system. This monitoring
extends from the capsule of a call station microphone Installation/configuration notes
to the end of a loudspeaker line. The external cables
connected to the control inputs are monitored for
short and open circuit. An internally generated pilot
tone is available for monitoring the audio outputs. The 7

controller operates both on mains power and on a 1 2

48 Vdc battery power supply for emergency back up,


with automatic switchover. It can supervise both of 3
8
4
the power supplies.
Controls and indicators
Front 10 13
2 x 16character LCD display
5 9
Rotary/push button
Back 11

Mains switch
Voltage selector 6
12 14
15

Interconnections
Front 1 Audio inputs
Headphone output
Back 2 Audio outputs
Mains input 3 Control inputs
Battery backup input
Eight control inputs 4 Control outputs
Two analog audio mic/line inputs
5 Plastic optical fiber network
Two analog line audio inputs
Five control outputs (two dedicated fault) 6 Mains in
Four analog audio line outputs
7 Display, control and buzzer
Ethernet
RS232
3 | PRS-NCO3 Network Controller

8 Network processor and DSP Input range +6 dBV to +18 dBV (XLR)
-6 dBV to +6 dBV (cinch)
9 Network redundancy switching
Control inputs 8x
10 Message manager
Connectors Removable screw terminals
11 Micro processor
12 Power supply Operation Closing contact (with supervision)

13 Compact flash (CF) memory card Control outputs 5x

14 24 Vdc out Connectors Removable screw terminals

15 48 Vdc backup power supply in Mic / line inputs 2x

Connector 3pin XLR

Nominal Input Level -57 dBV

S/N >62 dBA with 25 dB headroom

CMRR >55 dB at 100 Hz

Input Impedance 1360 ohm

Phantom supply 12 V 1 V @ 15 mA

Input range -7 dB to 8 dB ref nominal input level


PRS-NCO3 rear view
Line outputs 4x
Parts included
Connectors XLR and stereo cinch (for each line)
Quantity Component
Output Impedance <100 ohm
1 PRSNCO3 Network Controller
S/N >89 dBA at maximum level
1 Power cord
Crosstalk <-85 dB
1 Set of mounting brackets for 19rack
Signal range -12 dBV to +18 dBV (XLR)
1 Set of feet -24 dBV to +6 dBV (cinch)
1 Set of connectors Distortion at 1 kHz <0.05%
1 PRSSW Configuration, Diagnostic and Logging Software
Mechanical
Technical specifications Dimensions (H x W x D)
Electrical tabletop, with feet 92 x 440 x 400 mm
(3.6 x 17.3 x 15.7 in)
Mains power supply
in rack, with brackets 88 x 483 x 400 mm
Voltage 115/230 VAC 10%, 50/60 Hz (3.5 x 19 x 15.7 in)
Power consumption 21 W with no load in front of brackets 40 mm (1.6 in)
160 W with maximum load
behind brackets 360 mm (14.2 in)
Battery power supply

Voltage 48 Vdc -10% to +20% Weight 7 kg (15.4 lb)

Performance Mounting Standalone; 19" rack

Frequency response 20 Hz to 20 kHz (-3 dB) Color Charcoal with silver

Line inputs 2x Environmental


Connectors 3pin XLR and stereo cinch (for each Operating temperature -5 to +55 C (+23 F to +131 F)
line)
Storage temperature -40 to +70 C (-40 F to +158 F)
S/N >87 dBA at maximum level
Humidity 15% to 90%
CMRR >40 dB
Air pressure 600 to 1100 hPa
4 | PRS-NCO3 Network Controller

Ordering information

PRS-NCO3 Network Controller


System controller, router, supervisor and interface,
built-in web server for configuration, provides local
audio and control I/O, 4-channel WAV-message player,
power supply for powering other network connected
units, rack unit 2 RU.
Order number PRS-NCO3

PRSSW Praesideo Software


DVD with system software for Praesideo, used for
system configuration, diagnostics and logging,
supplied with PRS-NCO3.
Order number PRS-SW

Represented by:

Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:


Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division
12000 Portland Avenue South P.O. Box 80002 Systems 201 Building, No. 333 Fuquan Road Via Anhanguera, Km 98
Burnsville MN 55337, USA 5617 BA Eindhoven, The Netherlands 11 Bishan Street 21 North IBP CEP 13065-900
Phone: +1-800-392-3497 Phone: + 31 40 2577 284 Singapore 573943 Changning District, Shanghai Campinas, Sao Paulo, Brazil
Fax: +1-800-955-6831 Fax: +31 40 2577 330 Phone: +65 6571 2808 200335 China Phone: +55 19 2103 2860
audiosupport@us.bosch.com emea.securitysystems@bosch.com Fax: +65 6571 2699 Phone +86 21 22181111 Fax: +55 19 2103 2862
www.boschsecurity.com www.boschsecurity.com apr.securitysystems@bosch.com Fax: +86 21 22182398 latam.boschsecurity@bosch.com
www.boschsecurity.asia www.boschsecurity.com.cn www.boschsecurity.com

Bosch Security Systems 2015 | Data subject to change without notice


10198933899 | en, V13, 01. Jul 2015
Communications Systems | PRSxPxxx and LBB 4428/00 Power Amplifiers

PRSxPxxx and LBB 4428/00 Power


Amplifiers
www.boschsecurity.com

u 1, 2, 4, or 8 audio outputs (selection from 100 / 70 /


50 V outputs)

u Audio processing and delay for each amplifier


channel

u Amplifier supervision and spare amplifier switching

u Loudspeaker line and loudspeaker supervision


(LBB 4428/00 only line supervision)

u Eight control inputs and 1, 2, 4 or 8 control outputs

There are four types of Power Amplifier units in the control inputs are freely programmable for system
Praesideo product range. These differ in the number of actions, and priorities can be assigned to these inputs.
amplifier channels per frame: one, two, four, or eight. Each control input has the ability to monitor the
The overall power rating is 500 watts for all of the attached line for open and short-circuits. Control
amplifiers. outputs are freely programmable for faults and call
related actions.
The Power Amplifiers can be set to 100 V, 70 V and
50 V output tappings. They have short-to-ground and The 2 x 16character display and the rotary control
short-circuit detection functions, and can generate enable local status enquiries. The display shows the
their own pilot tone for supervision purposes. VUmeter reading, when the audio monitoring mode is
active. Audio can be monitored by headphone.
Notice
Region specific versions of these amplifiers are The units are self-monitoring and continually report
their status to the network controller. They support
indicated by a suffix to the typenumber (-EU, - both single branch and redundant loop cabling. The
CN, ...). The amplifiers are completely identical, amplifiers have a changeover facility for spare power
amplifier switching. Changeover relays are included
but may differ in certifications, power cord and
with the units. The amplifiers have a 48 V DC back-up
country of origin. supply input.

Functions The digital audio processing can handle three


parametric equalization sections and two shelving
The Power Amplifiers receive input signals over the equalization sections per channel with configurable
network. They also have two auxiliary audio inputs audio delay.
(four for LBB 4428/00) for local audio. Their eight
2 | PRSxPxxx and LBB 4428/00 Power Amplifiers

Controls and indicators 4 Loudspeaker outputs, 1 x, 2 x, 4 x, 8 x


2 x 16-character LCD for status display
Rotary/push control button 5 Spare amplifier input
Mains switch
6 Control outputs, 1 x, 2 x, 4 x, 8 x
Voltage selector for PRSxPxxx
7 Mains input
Interconnections
Mains input 8 48 V backup supply
Battery backup input
Two system network connections 9 Display and control
Two mic/line inputs (four for LBB 4428/00) 10 Network processor and DSP
Selectable 100 V, 70 V or 50 V outputs (per channel)
Fixed 50 V output 11 Network redundancy switching
Eight programmable control inputs
12 Power supply
Control output (for each amplifier channel)
Headphone output Block diagram
Spare amplifier connection (for each amplifier
channel) Parts included

Certifications and approvals Quantit Component


y
Safety acc. to IEC 60065 / EN 60065
1 PRSxPxxx or LBB 4428/00 Power Amplifier
Immunity acc. to EN 551032 / EN 501304 /
1 Power cord
EN 501214
1 Set of mounting brackets (large) for 19 rack
Emissions acc. to EN 55103-1 / FCC-47 part 15B
1 Set of feet
Emergency acc. to EN 60849 / EN 5416 /
ISO 724016 1 Set of connectors
Maritime acc. to IEC 60945
Technical specifications
Region Certification Electrical
Europe CPR EU_CPR Mains power supply
CE DOP Voltage

Installation/configuration notes PRSxPxxx 115 / 230 VAC 10%, 50/60 Hz

LBB 4428/00 100 to 240 VAC 10%, 50/60 Hz

Power consumption Pmax -3 dB* / idle** / standby


9 4
1
PRS1P500 350 / 50 / 20 W
5
PRS2P250 350 / 53 / 21 W
10 PRS4P125 350 / 66 / 23 W
2 6
LBB 4428/00 430 / 90 / 32 W

* Alarm tone level


** With pilot tone 15 V
3 11
Battery power supply

Voltage 48 VDC -10% to +20%


7
Power consumption Pmax -3 dB* / idle** / standby
12
8 PRS1P500 330 / 40 / 10 W

PRS2P250 330 / 43 / 11 W
1 Audio inputs, 2 x or 4 x PRS4P125 330 / 56 / 13 W
2 Control inputs
3 Plastic optical fiber network
3 | PRSxPxxx and LBB 4428/00 Power Amplifiers

LBB 4428/00 400 / 65 / 22 W (per channel) 250 W (30 min. at 55 C, cont. at


30 C)
* Alarm tone level
** With pilot tone 15 V 125 W (cont. at 55 C)

Connector 9pole header for removable screw


Mic/line inputs 2 x (4 x for LBB 4428/00) connector
Connector 6-pole header for removable screw
connector (mono, balanced) Loudspeaker outputs PRS2P250

Line Rated load resistance 40 ohm (100 V); 20 ohm (70 V)


10 ohm (50 V)
Frequency response -3 dB @ 50 Hz and 20 kHz (1 dB)
Rated load capacitance 125 nF (100 V); 250 nF (70 V) )
S/N >87 dBA 500 nF (50 V)
CMRR >40 dB @ 1 kHz Rated output power 250 W (1 min. at 55 C)
(per channel)
Input range -6 dBV to 6 dBV 125 W (30 min. at 55 C, cont. at
30 C)
Input impedance 22 kohm
60 W (cont. at 55 C)
Mic
Connector 9pole header for removable screw
Frequency response -3 dB @ 100 Hz and 16 kHz
connector
Nominal input level -57 dBV
Loudspeaker outputs PRS4P125
S/N >62 dBA with 25 dB headroom
Rated load resistance 80 ohm (100 V); 40 ohm (70 V)
CMRR 40 dB at 1 kHz 20 ohm (50 V)
Input impedance 1360 ohm Rated load capacitance 62 nF (100 V); 125 nF (70 V) ) 250 nF
(50 V)
Phantom supply 12 V 1 V @ 15 mA
Rated output power 125 W (1 min. at 55 C)
Input range -7 dBV to +8 dBV ref nominal input
(per channel)
value 60 W (30 min. at 55 C, cont. at 30 C)

Control inputs 8x 30 W (cont. at 55 C)

Connectors Removable screw terminals Connector 9pole header for removable screw
connector
Operation Closing contact (with supervision)
Loudspeaker outputs LBB 4428/00
Control outputs 1 x per amplifier channel
Rated load resistance 166 ohm (100 V); 83 ohm (70 V)
Connectors Removable screw terminals
42 ohm (50 V)

Performance Rated load capacitance 30 nF (100 V); 60 nF (70 V) ) 120 nF


(50 V)
Frequency response
Rated output power 60 W (1 min. at 55 C)
PRSxPxxx 60 Hz to 19 kHz (-3 dB) (per channel)
30 W (30 min. at 55 C, cont. at 30 C)
LBB 4428/00 80 Hz to 19 kHz (-3 dB)
15 W (cont. at 55 C)
S/N >85 dB (no pilot tone)
Connector 9pole header for removable screw
Crosstalk <80 dB at nominal load for 1 kHz connector
Distortion <0.3% (@ 1 kHz) @ 50% of rated Mechanical
output power
Dimensions (H x W x D)
Loudspeaker outputs PRS1P500
for tabletop use, with feet 92 x 440 x 400 mm
Rated load resistance 20 ohm (100 V); 10 ohm (70 V) 5 ohm (3.6 x 17.3 x 15.7 in)
(50 V)
for 19 rack use, with 88 x 483 x 400 mm
Rated load capacitance 250 nF (100 V); 500 nF (70 V) brackets (3.5 x 19 x 15.7 in)
1000 nF (50 V)

Rated output power 500 W (1 min. at 55 C)


4 | PRSxPxxx and LBB 4428/00 Power Amplifiers

in front of brackets 40 mm (1.6 in) LBB 4428/00-EU Power Amplifier 8 x 60 W


Rack unit 2 HU, 8channel power amplifier with
behind brackets 360 mm (14.2 in)
Praesideo network connection, 8 x 60 W.
Order number LBB 4428/00-EU
Weight
PRS1P500US Power Amplifier 1 x 500 W
PRS1P500 12.6 kg (27.78 lb)
1-channel power amplifier with Praesideo network
PRS2P250 13.6 kg (29.98 lb) connection, 1 x 500 W, rack unit 2 RU, USA version.
Order number PRS-1P500-US
PRS4P125 16.1 kg (35.49 lb)

LBB 4428/00 15.8 kg (34.83 lb) PRS2P250US Power Amplifier 2 x 250 W


2-channel power amplifier with Praesideo network
Mounting Standalone; 19-rack connection, 2 x 250 W, rack unit 2 RU, USA version.
Order number PRS-2P250-US
Color Charcoal with silver
PRS4P125US Power Amplifier 4 x 125 W
Environmental
4-channel power amplifier with Praesideo network
Operating temperature -5 C to +55 C (+23 F to +131 F) connection, 4 x 125 W, rack unit 2 RU, USA version.
Order number PRS-4P125-US
Storage temperature -20 C to +70 C (-4 F to +158 F)
LBB 4428/00US Power Amplifier 8 x 60 W
Relative humidity 15% to 90%
8-channel power amplifier with Praesideo network
Air pressure 600 to 1100 h Pa connection, 8 x 60 W, rack unit 2 RU, USA version.
Order number LBB4428/00-US
Ordering information
PRS1P500CN Power Amplifier 1 X 500 W
PRS1P500 Power Amplifier 1 x 500 W 1-channel power amplifier with Praesideo network
1-channel power amplifier with Praesideo network connection, 1 x 500 W, rack unit 2 RU, Chinese
connection, 1 x 500 W, rack unit 2 RU. version.
Order number PRS-1P500 Order number PRS-1P500-CN

PRS2P250 Power Amplifier 2 x 250 W PRS2P250CN Power Amplifier 2 x 250 W


2-channel power amplifier with Praesideo network 2-channel power amplifier with Praesideo network
connection, 2 x 250 W, rack unit 2 RU. connection, 2 x 250 W, rack unit 2 RU, Chinese
Order number PRS-2P250 version.
Order number PRS-2P250-CN
PRS4P125 Power Amplifier 4 x 125 W
4-channel power amplifier with Praesideo network PRS4P125CN Power Amplifier 4 x 125 W
connection, 4 x 125 W, rack unit 2 RU. 4-channel power amplifier with Praesideo network
Order number PRS-4P125 connection, 4 x 125 W, rack unit 2 RU, Chinese
version.
LBB 4428/00 Power Amplifier 8 x 60 W Order number PRS-4P125-CN
Rack unit 2 HU, 8-channel power amplifier with
Praesideo network connection, 8 x 60 W. LBB 4428/00CN Power Amplifier 8 x 60 W
Order number LBB4428/00 8-channel power amplifier with Praesideo network
connection, 8 x 60 W, rack unit 2 RU, Chinese version.
PRS1P500-EU Power Amplifier 1 x 500 W Order number LBB4428/00-CN
1channel power amplifier with Praesideo network
Accessories
connection, 1 x 500 W, rack unit 2 RU.
Order number PRS-1P500-EU LBB 4440/00 Supervision Control Board
Line and loudspeaker supervision master PCB for
PRS2P250-EU Power Amplifier 2 x 250 W mounting in a Praesideo network connected power
2channel power amplifier with Praesideo network amplifier, one board is needed per channel.
connection, 2 x 250 W, rack unit 2 RU. Order number LBB4440/00
Order number PRS-2P250-EU
LBB 4441/00 Loudspeaker Supervision Board
PRS4P125-EU Power Amplifier 4 x 125 W Loudspeaker supervision slave PCB for mounting on a
4channel power amplifier with Praesideo network loudspeaker, operates with LBB4440/00 for
connection, 4 x 125 W, rack unit 2 RU. monitoring the integrity of the loudspeaker.
Order number PRS-4P125-EU Order number LBB4441/00
Communications Systems | PRSCSR Call Station Remote

PRSCSR Call Station Remote


www.boschsecurity.com

u Connects to call station interface via CAT-5 cable

u Up to 1 km from Praesideo optical network

u Uses standard Praesideo keypads for extension

u Built-in limiter

u Powered via CAT-5 and/or local power supply

The PRSCSR is a call station with the same


functionality as the basic call station, LBB 4430/00, The remote call station connects via a CAT-5 cable to
but it uses CAT-5 cable for its connection to the an PRSCSI unit, which interfaces it to the Praesideo
Praesideo network. It connects, one-to-one, to the call optical network. The call station gets its power from
station interface, PRSCSI, which is part of the the interface unit via the CAT-5 cable, but is also
Praesideo optical network. The CAT-5 cable, carrying equipped with a local power supply connection for
digital audio and control data, can be as long as 1 km. extreme cases with a very long cable and many
The length of the CAT-5 cable is not a part of the keypads.
Praesideo optical network length. This considerably
increases the overall possible length of the optical Up to 16 call station keypads can connect to the
network. station via a serial communication link. The call station
The PRS-CSR can be extended with up to 16 keypads provides the power for the keypads. Up to 224
(LBB 4432/00 or LBB 4434/00), each with eight priorities can be assigned to the call station. All
programmable keys. Extension with a numeric keypad configuration can be done via the Praesideo network
(PRSCSNKP) is also possible. controller.
Functions
The remote call station is fully supervised and
The call station has a cardioid, supervised microphone supports fail-safe operation. Even if the Praesideo
on a gooseneck stem with good speech intelligibility. A network controller fails, the call station is still able to
limiter and a speech filter improve intelligibility and put through emergency calls.
prevent clipping of the audio. It has a volume control
for the monitoring speaker and the headset. When it Controls and indicators
Three status LEDs
plays a chime or a pre-recorded message, the call
Configurable PTT-key
station activates its speaker. When a headset is
Volume control for loudspeaker/headset
connected, it replaces the microphone and speaker.
2 | PRSCSR Call Station Remote

Interconnections 9 Data connection (CAT5)


RJ45 connector for CAT-5 connection
Serial data and power supply interface for call station 1 Control input
keypads 0
Kycon type (lockable) connector for power and two
control inputs Parts included
3.5 mm jack for headset/headphone
Quantit Component
Certifications and approvals y

Safety acc. to IEC 60065 / EN 60065 1 PRSCSR Call Station Remote


1 Flat cable
Immunity acc. to EN 551032 / EN 501304 /
EN 501214
Technical specifications
Emissions acc. to EN 55103-1 / FCC-47 part 15B
Electrical
Emergency acc. to EN 60849 / EN 5416 /
ISO 724016 External power supply 18 to 56 VDC

Maritime acc. to IEC 60945 Power consumption 3.3 W at 48 V without keypads

Microphone
Region Certification
Nominal acoustic input level 75 to 90 dB SPL
Europe CE
S/N > 60 dB at 85 dB SPL
CPD
Frequency response 340 Hz to 14 kHz (-3 dB)
Installation/configuration notes
Loudspeaker
1
S/N 80 dB at max.

3 3 Sound pressure level 85 dB (SPL) at 0.5 m and 1 kHz


(< 16)
Headset
2
Connector 3.5 mm jack
A/D D/A
Recommended type Hosiden HBH 0058
4
6 Control inputs 2x
PTT
7
I O Operation Closing contact (with supervision)
10 8
Mechanical
9 Dimensions (H x W x D) 90 x 160 x 200 mm (3.5 x 6.3 x 7.9
5 in)

Length of goose neck 380 mm (15 in)

Weight 1 kg (2.2 lb)

1 Headset Mounting Standalone


2 Microphone Color Charcoal
3 Keypad(s)
Environmental
4 Network processor and DSP
Operating temperature -5 C to +45 C (+23 F to +113 F)
5 Network redundancy switching
Storage temperature -20 C to +70 C (-4 F to +158 F)
6 Power/error
Humidity 15% to 90%
7 Call station status (two-color)
Air pressure 600 to 1100 hPa
8 Network status
3 | PRSCSR Call Station Remote

Ordering information

PRSCSR Call Station Remote


same functionality as the basic call station,
LBB 4430/00, but it uses CAT-5 cable for its
connection to the Praesideo network
Order number PRS-CSR
Accessories
PRSCSI Call Station Interface
an interface between a single remote call station,
PRSCSR, or a remote call station kit, PRSCSRK, and
the fiber optical Praesideo network.
Order number PRS-CSI

LBB 4432/00 Call Station Keypad


has eight programmable buttons, each with a two-
color status LED.
Order number LBB4432/00

LBB 4434/00 Call Station Keypad Kit


used in combination with a call station kit or call
station basic to make manual or pre-recorded
announcements to any assigned zones, or to execute
pre-defined actions.
Order number LBB4434/00

PRSCSNKP Numeric Keypad


can be used for user access, zone and zone group
selection. LCD for user feedback.
Order number PRS-CSNKP

Represented by:

Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:


Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division
12000 Portland Avenue South P.O. Box 80002 Systems 201 Building, No. 333 Fuquan Road Via Anhanguera, Km 98
Burnsville MN 55337, USA 5617 BA Eindhoven, The Netherlands 11 Bishan Street 21 North IBP CEP 13065-900
Phone: +1-800-392-3497 Phone: + 31 40 2577 284 Singapore 573943 Changning District, Shanghai Campinas, Sao Paulo, Brazil
Fax: +1-800-955-6831 Fax: +31 40 2577 330 Phone: +65 6571 2808 200335 China Phone: +55 19 2103 2860
audiosupport@us.bosch.com emea.securitysystems@bosch.com Fax: +65 6571 2699 Phone +86 21 22181111 Fax: +55 19 2103 2862
www.boschsecurity.com www.boschsecurity.com apr.securitysystems@bosch.com Fax: +86 21 22182398 al.securitysystems@bosch.com
www.boschsecurity.asia www.boschsecurity.com.cn www.boschsecurity.com

Bosch Security Systems 2012 | Data subject to change without notice


1872005003 | en, V4, 24. Nov 2012
Communications Systems | PRSCSNKP Numeric Keypad

PRSCSNKP Numeric Keypad


www.boschsecurity.com

u Numeric keypad for zone selection and user access

u Serial data and power interface to callstation basic

u Can be combined with normal callstation keypads

u LCD for user feedback

u Stylish and modern design

The CallStation Numeric Keypad is used in The LCD gives feedback to the user about the
combination with a basic or remote callstation. The selections and the status of the selected zones and
callstation provides the microphone and presstotalk zone groups.
key, while the numeric keypad can be used for user The keypad gets its power supply from the connected
access, zone and zone group selection. It works callstation. It is configured via the Preasideo network
together with callstation keypads for preconfigured controller (web browser interface).
actions. The builtin LCD provides feedback to the
Controls and indicators
user. 12 numeric keys
2 x 16 character LCD with backlight
Functions
LCD brightness adjustment
The callstation numeric keypad has a 12key numeric LCD contrast adjustment
keypad, providing a telephonelike user interface with Interconnections
*, # and 09 keys. A single numeric keypad connects Flatcable connection to callstation
directly to a basic or remote callstation and Flatcable connection to next keypad
subsequently up to 15 other keypads can be linked for
controlling functions. It is mechanically fixed to the Certifications and approvals
callstation. The numeric keypad can be configured for
the following functions: Safety acc. to IEC 60065 / EN 60065
User access to the callstation with user number and Immunity acc. to EN 551032 / EN 501304 /
PIN, configurable for multiple users, with timeout EN 501214
and manual lock
Selecting zones and zone groups as destinations for Emissions acc. to EN 55103-1 / FCC-47 part 15B
calls; up to eight zones and/or zone groups can be
Emergency acc. to EN 60849 / EN 5416 /
entered into a string.
ISO 724016

Maritime acc. to IEC 60945


2 | PRSCSNKP Numeric Keypad

Region Certification

Europe CE
CPD

Parts included

Quantity Component

1 PRSCSNKP Numeric Keypad

1 Flatcable

1 Coupling bracket

Technical specifications

Electrical

Power consumption 1.8 W (DC)

Mechanical

Dimensions (H x W x D) 70 x95 x 200 mm (2.8 x 3.7 x 7.9 in)

Weight 0.4 kg (0.9 lb)

Mounting Bracket attachment to a callstation or


other keypad

Color Charcoal

Environmental

Operating temperature -5 C to +45 C (+23 F to +113 F)

Storage temperature -20 C to +70 C (-4 F to +158 F)

Relative humidity 15% to 90%

Air pressure 600 to 1100 hPa

Ordering information

PRSCSNKP Numeric Keypad


can be used for user access, zone and zone group
selection. LCD for user feedback.
Order number PRS-CSNKP

Represented by:

Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:


Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division
12000 Portland Avenue South P.O. Box 80002 Systems 201 Building, No. 333 Fuquan Road Via Anhanguera, Km 98
Burnsville MN 55337, USA 5617 BA Eindhoven, The Netherlands 11 Bishan Street 21 North IBP CEP 13065-900
Phone: +1-800-392-3497 Phone: + 31 40 2577 284 Singapore 573943 Changning District, Shanghai Campinas, Sao Paulo, Brazil
Fax: +1-800-955-6831 Fax: +31 40 2577 330 Phone: +65 6571 2808 200335 China Phone: +55 19 2103 2860
audiosupport@us.bosch.com emea.securitysystems@bosch.com Fax: +65 6571 2699 Phone +86 21 22181111 Fax: +55 19 2103 2862
www.boschsecurity.com www.boschsecurity.com apr.securitysystems@bosch.com Fax: +86 21 22182398 al.securitysystems@bosch.com
www.boschsecurity.asia www.boschsecurity.com.cn www.boschsecurity.com

Bosch Security Systems 2012 | Data subject to change without notice


1871013771 | en, V4, 24. Nov 2012
Communication Systems | LBB 4432/00 Call Station Keypad

LBB 4432/00 Call Station Keypad


Eight freely programmable selection keys
Serial data and power interface to call station basic
Up to 16 keypads can be connected to one call station
basic
Activation indicator for each key
Stylish and modern design

The call station keypad is used in combination with the call Eight two-color LEDs
station basic to make manual or pre-recorded Interconnections
announcements to any assigned zones, to select the zones Two serial data and power connections
or to execute pre-defined actions. The call station keypad
has eight programmable buttons, each with a two-color
status LED. Certifications and Approvals

Region Certification
Functions
Europe CE Declaration of Conformity
The keys of the call station keypad can be programmed for
SOLAS
actions, such as:
TUV Certificate IEC60849
Controlling functions: selection recall, call activation,
cancel selection, BGM off, BGM volume control, fault
Safety acc. to IEC 60065-98
acknowledgement, etc.
Selecting sources: BGM channel, pre-recorded Immunity acc. to EN 55103-2
messages, attention and alarm tones Emissions acc. to EN 55103-1 / FCC-47 part 15B
Selecting destinations: zones and zone groups
EVAC (TV certified) acc. to IEC 60849 / BS 5839-8
The keys can be programmed for different modes of
operation, such as momentary or toggle. Each key has one
two-color status LED beside it. Beside each LED is a Parts Included
transparent, removable tab that can hold a function or zone
label for the key. Safety covers to prevent accidental Quantity Component
activation of the keys are available as an option. 1 LBB 4432/00 Call Station Keypad
The keypad gets its power from the call station it is 1 Flat cable
connected to. 1 Coupling bracket
Controls and indicators 1 Set of text labels
Eight function keys

www.boschsecurity.com
2 | LBB 4432/00 Call Station Keypad

Technical Specifications
Electrical

Power consumption 1.1 W (DC)


Mechanical

Dimensions (H x W x D) 70 x 95 x 200 mm (2.8 x 3.7 x 7.9 in)


Weight 0.3 kg (0.7 lb)
Mounting Bracket attachment to a call station basic or
other keypad
Color Charcoal
Environmental

Operating temperature -5 C to +55 C (+23 F to +131 F)


Storage temperature -20 C to +70 C (-4 F to +158 F)
Humidity 15% to 90%
Air pressure 600 to 1100 hPa

Ordering Information
LBB 4432/00 Call Station Keypad
Accessories
LBB 4436/00 Set of Key Covers (10 pcs)
10 key covers and 10 replacement lenses

Europe, Middle East, Africa: Americas: Asia-Pacific: Represented by


Bosch Security Systems B.V. Bosch Security Systems, Inc. Bosch Security Systems Pte Ltd
P.O. Box 80002 130 Perinton Parkway 38C Jalan Pemimpin
5600 JB Eindhoven, The Netherlands Fairport, New York, 14450, USA Singapore 577180
Phone: + 31 40 2577 284 Phone: +1 800 289 0096 Phone: +65 6319 3450
Fax: +31 40 2577 330 Fax: +1 585 223 9180 Fax: +65 6319 3499
emea.securitysystems@bosch.com security.sales@us.bosch.com apr.securitysystems@bosch.com
www.boschsecurity.com www.boschsecurity.us www.boschsecurity.com

Bosch Security Systems B.V. 007 | Data subject to change without notice
E2091057035 | Cur: en-US, V5, 2 Oct 2007
Communications Systems | PRSCSI Call Station Interface

PRSCSI Call Station Interface


www.boschsecurity.com

u Connects a remote call station to the Praesideo


network via CAT5 cable (up to 1 km)

u Powered by the Praesideo network and/or local


power supply

u Two supervised control inputs

u Builtin DSP for audio processing functions

u Complete supervision of the unit

The PRSCSI is an interface between a single remote of remote call stations, allowing them to put through
call station, PRSCSR, or a remote call station kit, emergency calls, even if the network controller fails.
PRSCSRK, and the fiber optical Praesideo network. It The unit is configured via the network controller.
uses CAT-5 cable for the connection to the remote call
Controls and indicators
station. The CAT5 cable, carrying digital audio and Two LED indicators for power and network status
control data, can be as long as 1 km. The length of the Two jumpers (below cover) to separate power supply
CAT5 cable is not a part of the Praesideo optical of call station interface and remote call station
network length. This considerably increases the overall
possible length of the optical network, especially in Interconnectors
Two Praesideo network connectors
cases, where the call station is located far from the
RJ45 connector for CAT5 connection
rest of the system.
Kycon type (lockable) connector for power and two
control inputs
The call station interface can get its power from the
Praesideo network, and/or from a local power supply. Certifications and approvals
It is fully supervised.
Safety acc. to IEC 60065 / EN 60065
Functions
Immunity acc. to EN 551032 / EN 501304 /
The interface can connect a single PRSCSR remote EN 501214
call station or PRSCSRK remote call station kit to a Emissions acc. to EN 55103-1 / FCC-47 part 15B
Praesideo system with up to 1 km of CAT5 cable.
The interface is fully digital, supporting high-quality Emergency acc. to EN 60849 / EN 5416 /
ISO 724016
sound with a built-in DSP for audio processing of the
remote call station. It supports complete supervision Maritime acc. to IEC 60945
of itself, the call station, and the connection, as well
as of two control inputs. It supports the fail safe mode
2 | PRSCSI Call Station Interface

Region Certification Control inputs 2x

Europe CPR EU_CPR Operation Closing contact (with supervision)

CE Mechanical
CE COC
Dimensions (H x W x D) 27 x 243 x 80 mm without bracket
CE CertAlarm (1.1 x 9.6 x 3.1 in)
34 x 243 x 84 mm with bracket
CE DOP (1.3 x 9.6 x 3.3 in)
GL Weight 0.7 kg (1.5 lb)

Installation/configuration notes Mounting Bracket (2 screws)

Color Charcoal
1 2
Environmental

6 6 3 Operating temperature -5 C to +55 C (+23 F to +131 F)

Storage temperature -20 C to +70 C (-4 F to +158 F)


7 8 Humidity 15% to 90%
5 10
Air pressure 600 to 1100 hPa

Ordering information

PRSCSI Call Station Interface


4 9 Compact unit with mounting clamp, interface between
Praesideo network and a remote CAT-5 connected call
station up to 1000 m away, powered from Praesideo
network.
1 Fault LED Order number PRS-CSI

2 Power LED Accessories


PRSCSR Call Station Remote
3 CAT5
Call station for remote locations with microphone on a
4 POF flexible stem, push-to-talk button, monitoring
5 External (backup) power 1856 V loudspeaker, to be connected to a PRS-CSI via a CAT-5
cable.
6 Control inputs Order number PRS-CSR
7 Network processor and DSP PRSCSRK Call Station Remote Kit
8 UTP interface PCB for custom remote call station, connections for
microphone, push-to-talk button, monitoring
9 Network redundancy switching
loudspeaker, to be connected to a PRS-CSI via a
10 Power supply CAT-5 cable.
Order number PRS-CSRK
Parts included

Quantit Component
y
1 PRSCSI Call Station Interface
1 Power supply connector

Technical specifications

Electrical

External power supply 18 to 56 VDC

Power consumption 3.7 W


Communications Systems | PLE-SDT Plena Easy Line SD Tuner BGM source

PLE-SDT Plena Easy Line SD Tuner BGM


source
www.boschsecurity.com

u MP3 playback from SD card and USB inputs

u FM tuner with RDS, presets and digital control

u Simultaneous operation of SD/USB-player and FM


tuner

u Separate outputs for digital source and FM tuner

The PLE-SDT Plena Easy Line SD Tuner BGM source is from a single source. It supports music organized on a
the ideal highquality source for background music disk in multiple folders. The player will automatically
(BGM) in public address systems. It provides hours of search and play all playable MP3s on a flash memory
uninterrupted music for professional systems. device, and has repeat and random play modes.
Designed without moving parts, it can be used in
Digital Source
systems that are on for long periods. It is designed to
It can play MP3s with bit-rates from 32 kbps to
be used with non-volatile steady state flash memory.
320 kbps, mono / stereo / jointstereo, and both
System overview constant bit-rates (CBR) and variable bit-rate (VBR)
are supported.
The unit has a digital source side for MP3s stored on
Tuner
SD card and USB memory stick, and a side with an FM The digitally controlled FM tuner uses a frequency
tuner. It is typically used in hotels, shops, synthesizer for accurate capture of radio stations and
supermarkets, restaurants, bars, canteens, gyms, has presets for FM to store favorite radio stations.
showrooms, and other places where BGM creates the
right atmosphere. It connects to any public address Outputs
amplifier. The design follows the Plena Easy Line Both the player and the tuner can operate
design and is part of the Advantage Line by Bosch. simultaneously on different outputs. The output level
of the outputs can be set via the rear panel. Next to
Functions the stereo analog outputs per side, there is a
combined output that plays the digital content and
Insert only one USB stick at the time.
If a USB stick is inserted in the front,
this socket cannot be used, and vice versa
OUTPUT LEVEL OUTPUTS
230V~50Hz 50W or 115V~60Hz 50W
automatically switches over to the FM tuner when the
ANTENNA TUNER COMBINED USB/SD R L
TUNER
R L
COMBINED
R L
USB/SD
USE ONLY WITH 250V FUSE
230V~FUSE T0.63A/250V or
115V~FUSE T1.25A/250V last track has been played.
With an SD/USB capacity of up to 32 GB (up to 2000
tracks) and the option to connect the USB either on
the front or rear panel, the digital player provides
hours of highquality, uninterrupted music playback
2 | PLE-SDT Plena Easy Line SD Tuner BGM source

Certifications and approvals FM tuner

Safety according to IEC/EN 60065 Distortion <1%

CCC Total harmonic distortion (1 kHz) < 0.8 %

CTick FM range 87.5 108 MHz

CE EN 55013+A1+A2, Frequency response 50 Hz 12 kHz

EN 6100032, Channel separation (1 kHz) 40 dB

EN 6100033+A1 Intermediate rejection 70 dB

2006/95/CE LVD Directive Signal / noise ratio 50 dB

2004/108/CE EMC Intermediate frequency 10.7 MHz

IEC EN 55020+A2+EC Input sensitivity 6 V e.m.f. (2 uV)

CE marking Automatic tuning sensitivity 50 V

Antenna input 75 ohms (coaxial)


Region Certification
Audio output level - 10 dBV
Europe CE
SD / USB audio player
Installation/configuration notes
Maximum storage capacity 32 GB
The PLESDT is a 19 rackmount unit with detachable
Maximum number of tracks 2000
rack mount brackets for tabletop use. The unit comes
with an IR remote control to control all sources. It is Frequency response 50 Hz 20 kHz
compatible with High Capacity Secure Digital (SDHC),
MMC memory cards, Flash USB sticks and bus Signal / noise ratio 70 dB
powered (2.5) hard disk drives (HDD). System Total harmonic distortion (1 kHz) < 0.1 %
connection cables are included.
Stereo separation 60 dB
Parts included
Audio output level - 10 dBV
Quantity Components
Mechanical
1 PLE-SDT Plena Easy Line SD Tuner BGM source
Dimensions (H x W x D) 44 x 444 x 250 mm
1 AC Power cord (1.73 x 17.48 x 9.84 in)
1 Safety instructions Mounting Stand-alone, 19" rack
(19" wide, 1U high)
1 Set of 19mounting brackets
Color Charcoal with silver printing
1 Remote control
2 2pair audio RCA cable (2.5 m) Weight Approx. 3.6 kg

1 SD card including free music and the instructions for use Environmental

Technical specifications Operating temperature -25 C to +45 C

Storage temperature -40 C to +70 C


Electrical
Relative humidity < 90 % (non condensing)
Mains power supply

Voltage 115 - 230 VAC 10%, Ordering information


50/60 Hz
PLE-SDT Plena Easy Line SD Tuner BGM source
Power supply fuses 230 VAC 0.63 AT / 250 V USB/SD MP3 player with FM tuner functions.
120 VAC 1.25 AT / 250 V Order number PLE-SDT

Power consumtion (typical) 10 W

Power consumption (Max.) 50 VA


Communications Systems | LBC 3086/41 Ceiling Loudspeaker

LBC 3086/41 Ceiling Loudspeaker


www.boschsecurity.com

u Suitable for speech and music reproduction

u Flush-mounting in ceiling cavity

u Easy to install

u Simple power setting

u Optional certified fire dome

Voice alarm loudspeakers are specifically designed for Certifications and approvals
use in buildings where performance of systems for
verbal evacuation announcements is governed by All Bosch loudspeakers are designed to withstand
regulations. The LBC 3086/41 is designed for use in operating at their rated power for 100 hours in
voice alarm systems. accordance with IEC 268-5 Power Handling Capacity
(PHC) standards. Bosch has also developed the
Functions Simulated Acoustical Feedback Exposure (SAFE) test
to demonstrate that they can withstand two times
The loudspeaker unit is a 6 W, dual-cone loudspeaker their rated power for short durations. This ensures
with an integrated circular metal grille. A 100 V extra reliability under extreme conditions, leading to
matching transformer is mounted on the back. The higher customer satisfaction, longer operating life, and
appearance and neutral white RAL color have been much less chance of failure or performance
selected to be unobtrusive in virtually all interiors. deterioration.
The loudspeaker has built-in protection to ensure that,
in the event of a fire, damage to the loudspeaker does Safety acc. to EN 60065
not result in failure of the circuit to which it is
connected. In this way, system integrity is maintained, * Emergency acc. to BS 58398 /* EN 5424 / EN 60849
ensuring loudspeakers in other areas can still be used * Water and acc. to EN 60529IP32
to inform people of the situation. The loudspeaker has dust protection
ceramic terminal blocks, thermal fuse and heat-
* only in combination with the LBC 3081/02 Fire Dome
resistant, high-temperature wiring. It can also be fitted
with an optional fire-dome to increase protection of
the cable termination.
2 | LBC 3086/41 Ceiling Loudspeaker

Region Certification 90
3.54
Europe CE
CPD
Poland CNBOP

Installation/configuration notes

Installation
The assembly is quickly installed into a hole in the
ceiling cavity. A separate mounting ring, secured by
three integral spring-loaded ceiling locking clamps (for
ceilings and wall boards from 9 to 25 mm thick) holds
it in place. The clamps are provided with protective
rubbers to avoid damaging soft ceiling material. A
circular template for marking a 196 mm (7.7 in)
diameter hole is included with the loudspeaker. The
loudspeaker unit is held in the mounting ring with a Dimensions in mm (in)
bayonet fitting.
Terminal Block
The unit has a three-way terminal block with screw
connections suitable for loop-through wiring. Four
primary taps are provided on the matching transformer
to allow selection of nominal full-power, half-power,
quarter-power or eighth power radiation (i.e. in 3 dB
steps).
LBC 3081/02 Fire Dome Assembly
During a fire, the ceiling cavity in which loudspeakers
are installed can allow flames to spread throughout a
building. To prevent fire entering the caving via the Circuit diagram
loudspeaker, the ceiling loudspeaker can be fitted with
a protective steel fire dome (LBC 3081/02).

LBC 3086/41 with LBC 3081/02 fire dome assembly


dimensions in mm (in)

LBC 3086/41 with LBC 3081/02 fire dome assembly

Frequency response
3 | LBC 3086/41 Ceiling Loudspeaker

Opening angle 180 / 50


at 1 kHz/4 kHz (-6 dB)

Rated voltage 100 V

Rated impedance 1667 ohm

Connector 3-pole screw terminal block


* Technical performance data acc. to IEC 60268-5
Mechanical

Diameter 216 mm (8.5 in)

Maximum depth 90 mm (3.54 in)

Ceiling thickness 9 to 25 mm (0.35 to 0.98 in)

Mounting cut-out 196 mm (7.7 in)

Weight 1.3 kg (2.86 lb)

Color off-white (RAL 9010)

Magnet weight 150 g (5.3 oz)


Polar diagram (measured with pink noise)
Environmental

Operating temperature -25 C to +55 C (-13 F to +131 F)


125 250 500 1 2 4 8
Hz Hz Hz kHz kHz kHz kHz Storage temperature -40 C to +70 C (-40 F to +158 F)

SPL 1.1 92 90 85 90 96 98 92 Relative humidity <95%

SPL max. 100 98 93 98 10 10 10 Other parameters are available in CNBOP test report
4 6 0 nr 4781/BA/10.

Q-factor 4.8 4.4 2.5 3.7 8.3 20 21

Efficienc 0.42 0.29 0.16 0.3 0.6 0.4 0.1


y 4

H. angle 160 160 180 16 90 50 40


1438
0
Bosch Security Systems BV
V. angle 160 160 180 16 90 50 40 Kapittelweg 10, 4827 HG Breda, The Netherlands
0 10
1438-CPD-0193
Acoustical performance specified per octave
EN 54-24:2008
Parts included
Loudspeaker for voice alarm systems
for fire detection and fire alarm systems for buildings
Quantity Components
Ceiling Loudspeaker 6 W with metal Fire-dome
1 LBC 3086/41 Ceiling Loudspeaker LBC3086/41 and LBC3081/02
Type A
1 196 mm circular template
Ordering information
Technical specifications
LBC 3086/41 Ceiling Loudspeaker
Electrical*
6 W, dual-cone loudspeaker with an integrated circular
Maximum power 9W metal grille.
Order number LBC3086/41
Rated power 6 / 3 / 1.5 / 0.75 W
Accessories
Sound pressure level 98 dB / 90 dB (SPL)
at 6 W / 1 W (1 kHz, 1 m) LBC 3081/02 Fire Dome
metal fire dome for LBC 3086/41 ceiling loudspeaker
Effective frequency range 90 Hz to 20 kHz Order number LBC3081/02
(-10 dB)
Communications Systems | LBC 3081/02 Fire Dome

LBC 3081/02 Fire Dome


www.boschsecurity.com

During a fire, the ceiling cavity in which loudspeakers Installation/configuration notes


are installed can allow flames to spread throughout a
building. To prevent fire entering the cavity via the
loudspeaker, the ceiling loudspeaker can be fitted with
a steel fire dome (LBC 3081/02). This optional fire
dome is clicked into the mounting-ring via three leaf
springs, before the loudspeaker is inserted. For extra
convenience, a safety cord from the fire dome allows
the installer to temporarily hang the loudspeaker unit
during installation. This cord also provides
reassurance after installation. The fire-dome has
knockout holes for two grommets (supplied) and two
cable glands (PG 13).
This fire dome can only be used with the LBC 3086/41
Ceiling Loudspeaker.

Notice LBC3086/41 + LBC 3081/02 fire dome assembly


Product photo includes LBC 3086/41 dimensions in mm (in)

Parts included
Certifications and approvals
Quantity Components
Region Certification
1 LBC 3081/02 Fire Dome
Europe CE Declaration of Conformity
1 Safety cord
2 Rubber grommets
2 | LBC 3081/02 Fire Dome

Technical specifications

Mechanical

Dimensions (dia. x max. depth) 157 x 70 mm (6.2 x 2.8 in)

Weight 360 g (0.8 lb)

Color Flame red (RAL 3000)

Certified B15 Acc. to DIN 4102

Ordering information

LBC 3081/02 Fire Dome


metal fire dome for LBC 3086/41 ceiling loudspeaker
Order number LBC3081/02

Represented by:

Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina:


Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division
12000 Portland Avenue South P.O. Box 80002 Systems 201 Building, No. 333 Fuquan Road Via Anhanguera, Km 98
Burnsville MN 55337, USA 5617 BA Eindhoven, The Netherlands 11 Bishan Street 21 North IBP CEP 13065-900
Phone: +1-800-392-3497 Phone: + 31 40 2577 284 Singapore 573943 Changning District, Shanghai Campinas, Sao Paulo, Brazil
Fax: +1-800-955-6831 Fax: +31 40 2577 330 Phone: +65 6571 2808 200335 China Phone: +55 19 2103 2860
audiosupport@us.bosch.com emea.securitysystems@bosch.com Fax: +65 6571 2699 Phone +86 21 22181111 Fax: +55 19 2103 2862
www.boschsecurity.com www.boschsecurity.com apr.securitysystems@bosch.com Fax: +86 21 22182398 al.securitysystems@bosch.com
www.boschsecurity.asia www.boschsecurity.com.cn www.boschsecurity.com

Bosch Security Systems 2012 | Data subject to change without notice


1943015563 | en, V2, 24. Nov 2012
Communications Systems | LBC 3018/01 Metal Cabinet Loudspeaker

LBC 3018/01 Metal Cabinet Loudspeaker


www.boschsecurity.com

u Suitable for speech and music reproduction

u Robust metal enclosure

u Surface and/or recessed mounting

u Provision for internal mounting of the optional line/


loudspeaker supervision boards

u EN 54-24 certified

The LBC 3018/01 cabinet loudspeaker delivers Certifications and approvals


professional performance from a robust, yet
aesthetically designed metal enclosure. It is an ideal All Bosch loudspeakers are designed to withstand
loudspeaker for indoor use in offices, schools, car operating at their rated power for 100 continuous
parking, shopping centers and in areas where hours in accordance with IEC 2685 Power Handling
vandalism is a potential hazard. Capacity (PHC) standards. Bosch has also developed
The cabinets are equipped with a high efficiency, dual- the Simulated Acoustical Feedback Exposure (SAFE)
cone loudspeaker offering a wide frequency range test to demonstrate that they can withstand two times
suitable for both speech and music reproduction. their rated power for short durations. This ensures
improved reliability under extreme conditions, leading
Functions to higher customer satisfaction, longer operating life,
and lessens the chance of failure or performance
Voice alarm loudspeakers are specifically designed for deterioration.
use in buildings, where the performance of PA-systems
is subject to official regulations. The LBC 3018/01 is Safety acc. to EN 60065
designed for voice alarm systems, and is compliant
with the EN 54-24 standard. Emergency acc. to EN 5424, BS 58398 and
EN 60849
The loudspeaker has built-in protection to ensure that,
in the event of a fire, damage to the loudspeaker does Water and dust protection acc. to EN60529 IP32
not result in failure of the circuit to which it is
connected. In this way, system integrity is maintained, Region Certification
ensuring loudspeakers in other areas can still be used
to inform people of the situation. The loudspeaker has Europe CPR EU_CPR
a ceramic terminal block, thermal fuse, and heat- CE
resistant, high-temperature wiring.
The cabinet has a provision for internally mounting the Poland CNBOP
optional line/loudspeaker supervision board.
2 | LBC 3018/01 Metal Cabinet Loudspeaker

Installation/configuration notes C C
6W -
3W 6W
4
1.5W 3W
0.75W 1.5W
- 0.75W
70V 100V

Circuit diagram

Mounting dimensions in mm (in)

Frequency response
2x 20

Dimensions in mm (in)
The cabinet is designed for both surface mounting on
walls and recessed mounting into brick or concrete
walls. The backbox of the cabinet provides a selection
of mounting holes, even for mounting onto U40 and
MK installation boxes. The backbox has two knockout
holes on the topside for two cable glands for loop-
through connection. For extra convenience, a safety
cord from the backbox lets the installer temporarily
hang the front grille unit during installation.

Polar diagram (measured with pink noise)

250 Hz 500 Hz 1 2 4 8
kHz kHz kHz kHz

SPL 1.1 84 93 94 97 97 93

SPL max. 92 101 102 105 105 103


Surface mounted (left) and recessed (right) mounted
The cabinet has a three-way terminal block with screw Q-factor 2.5 3.3 7.9 8.5 12.9 14.2
connections suitable for loop-through wiring (including Efficiency 0.32 2.2 4 7.1 5.6 2.5
earth) Four primary taps are provided on the matching
transformer to allow selection of nominal full-power, H. angle 180 180 120 85 55 40
half-power, quarter-power or eighth power radiation V. angle 180 180 80 110 60 35
(in 3 dB steps).
Acoustical performance specified per octave
3 | LBC 3018/01 Metal Cabinet Loudspeaker

Technical specifications Ordering information

Electrical* LBC 3018/01 Metal Cabinet Loudspeaker


Cabinet loudspeaker 6 W, rectangular, metal
Maximum power 9W
enclosure, water and dust protected IP32, EN54-24
Rated power (PHC) 6W certified, white RAL 9010.
Order number LBC3018/01
Power tapping 6 / 3 / 1.5 / 0.75 W

Sound pressure level 102 dB / 94 dB (SPL)


at 6 W / 1 W (1 kHz, 1 m)

Effective frequency Range 150 Hz to 20 kHz


(-10 dB)

Opening angle 120 / 55


at 1 kHz / 4 kHz (-6 dB)

Rated voltage 70/100 V

Rated impedance 835/1667 ohm

Connector 3-pole screw terminal block


* Technical performance data acc. to IEC 602685
Mechanical

Dimensions 195 x 260 x 80 mm


(H x W x D) (7.68 x 10.24 x 3.15 in)

Weight 2.6 kg (5.78 lb)

Color White ( RAL 9010)

Speaker size 152.4 mm (6 in)

Magnet weight 150 g (5.3 oz)

Environmental

Operating temperature -25 C to +55 C (-13 F to


+131 F)

Storage temperature -40 C to +70 C (-40 F to


+158 F)

Relative humidity <95%


Other parameters are available in CNBOP test report
nr 4783/BA/10.

1438

Bosch Security Systems BV


Kapittelweg 10, 4827 HG Breda, The Netherlands
10
1438-CPD-0202

EN 54-24:2008

Loudspeaker for voice alarm systems


for fire detection and fire alarm systems for buildings

Metal Cabinet 6 W
LBC3018/01
Type A
Communications Systems | LP1UC20E1 Unidirectional Sound Projector

LP1UC20E1 Unidirectional Sound


Projector
www.boschsecurity.com

u Superb speech and music reproduction

u Integrated connection cable

u Ceiling or wall mounting

u Water and dust protected to IP 65

u EN 5424 certified

The LP1UC20E1 is a powerful 20 W sound projector not result in failure of the circuit to which it is
intended for high quality speech and music connected. In this way, system integrity is maintained;
reproduction in indoor and outdoor applications. The ensuring loudspeakers in other areas can still be used
stateoftheart design is matched to both modern and to inform people of the situation. The loudspeaker has
traditional style environments. The sound projector is a ceramic terminal block, thermal fuse and heat
suitable for use in voice alarm systems. resistant, high-temperature wiring.
The sound projector is made from highimpact
Functions selfextinguishing ABS according to class UL 94 V 0,
Superb sound quality finished in white.
The use of a highquality driver in combination with
Certifications and approvals
advanced filtering has resulted in a very natural sound
reproduction with excellent bass response. All Bosch loudspeakers are designed to withstand
Voice alarm loudspeaker operating at their rated power for 100 continuous
Voice alarm loudspeakers are specifically designed for hours in accordance with IEC 2685 Power Handling
use in buildings where performance of systems for Capacity (PHC) standards. Bosch has also developed
verbal communication announcements is governed by the Simulated Acoustical Feedback Exposure (SAFE)
regulations. The LP1UC20E1 is designed for use in test to demonstrate that they can withstand two times
voice alarm systems, is EN 5424 certified and their rated power for short durations. This ensures
compliant with BS 58398 and EN 60849. The sound improved reliability under extreme conditions, leading
projector is prewired for use with an optional line/ to higher customer satisfaction, longer operating life
loudspeaker supervision board external mounted. The and lessons the chance of failure or performance
loudspeaker has builtin protection to secure that, in deterioration.
the event of a fire; damage to the loudspeaker does
2 | LP1UC20E1 Unidirectional Sound Projector

Safety aspects
In common with all Bosch products, care is taken to 23 (0.90)
(0.43) 11
meet high safety standards.
14 (0.55)

All ABS parts are selfextinguishing (according to 6 (0.24)

(7.28)
185
UL 94 V 0). This sound projector complies with the

(4.29)
109
relevant safety and installation regulations of
120
EN 60065. (13.43) (5.43)
341 138 27 (1.06)

Water and dust protection according to IEC 60529, IP 65 (1.57) 40


(5.67)
Emergency according to EN 5424 / BS 58398 / 144 41 (1.61) (5.67)
144
EN 60849
(3.03) 77 (1.34) 34
Region Certification

(11.93)
303
(7.28)
185
Europe CE
CE DOP (11.81) (7.28)
300 185
CPD
Dimensions in mm / (in)
Poland CNBOP
0
Installation/configuration notes 20W

Mounting 10W
Ease of installation is realized in the way of mounting:
first the mounting plate is fixed to the wall or ceiling,
5W

secondly a safety cord is attached to the mounting 2.5W

plate, allowing the installer temporarily hang the


loudspeaker during installation. After making the
connections, the sound projector can be fixed to the
mounting plate, by means of a fixing screw nut, and Circuit diagram
the horizontal direction can be fixed. A cover plate
covers screws and wiring. The versatile mounting
bracket allows the sound projector to be horizontal
and vertical directed. The vertical direction can be
permanent fixed with a recessed socket head screw
via a small hole located in the rear panel. The cover
plate is provided with two cable or 16 mm (0.63
inch) conduit entries (covered as standard supplied)
in opposite position, suitable for loopthrough cabling.
Frequency response
Power setting
A ceramic terminal for electrical connection is
provided. The loudspeaker is standard connected to
full power. Halfpower, quarterpower or eighthpower
can be selected by connecting the appropriate color-
coded wire to the terminal block.

Polar diagram (measured with pink noise)


3 | LP1UC20E1 Unidirectional Sound Projector

Mechanical

Octave band sensitivity* Dimensions (D x L) 185 x 300 mm (7.3 x 11.8 in.)

Octave SPL Total octave Total octave Weight 3 kg (6.6 lb)


1W/1m SPL SPL
1W/1m Pmax/1m Color White (RAL 9010)

125 Hz 84.5 - - Material ABS

250 Hz 85.5 - - Environmental


500 Hz 84.7 - - Operating temperature -25 C to +55 C
(-13 F to +131 F)
1000 Hz 87.2 - -
Storage temperature -40 C to +70 C
2000 Hz 90.2 - - (-40 F to +158 F)
4000 Hz 92.1 - - Relative humidity <95%
8000 Hz 95.9 - -

A-weighted - 89.4 101.0

Lin-weighted - 91.3 102.3

Octave band opening angles 1438

Horizontal Vertical Bosch Security Systems BV


Torenallee 49, 5617BA Eindhoven, The Netherlands
125 Hz 360 360 10
1438-CPD-0258
250 Hz 360 360
EN 54-24:2008
500 Hz 360 360
Loudspeaker for voice alarm systems
for fire detection and fire alarm systems for buildings
1000 Hz 226 226
Unidirectional Sound Projector 20W
2000 Hz 124 124 LP1-UC20E-1
Type B
4000 Hz 65 65

8000 Hz 34 34 Ordering information


Acoustical performance specified per octave * (all
LP1UC20E1 Unidirectional Sound Projector
measurements are done with a pink noise signal; the
Sound projector 20 W, unidirectional, white ABS
values are in dBSPL).
enclosure with metal grilles, water and dust protected
Technical specifications IP65, EN54-24 certified, white RAL 9010.
Order number LP1-UC20E-1
Electrical*

Maximum power 30 W

Rated power 20 / 10 / 5 / 2.5 W

Sound pressure level 100 dB / 87 dB (SPL)


at 20 W / 1 W (1kHz, 1 m)

Opening angle 220 / 65


at 1 kHz / 4 kHz (-6 dB)

Effective frequency range (-10 75 Hz to 20 kHz


dB)

Rated voltage 100 V

Rated impedance 500 ohm

Connector 3pole screw terminal


* Technical performance data accordance to
IEC 602685
Communications Systems | LBB 4442/00 Line Supervision Set

LBB 4442/00 Line Supervision Set


www.boschsecurity.com

u Loudspeaker line monitoring without additional


cabling

u Supervision-master mounting in the power amplifier

u Supervision-slave mounting at the end of the


loudspeaker line

u Open-circuit fault detection

u Compatible with 100 V and 70 V loudspeaker lines

The Praesideo system uses a unique loudspeaker line Interconnections


monitoring principle, which requires no additional 20-pin flat cable connector (master)
cable. The loudspeaker line itself is used to Two screw terminals (slave)
communicate with the supervision-slave installed at Certifications and approvals
the end of the loudspeaker line.
The LBB 4442/00 contains the master and slave device Safety acc. to IEC 60065 / EN 60065
for supervision of a single loudspeaker line. For
supervision of multiple loudspeaker line branches and Immunity acc. to EN 551032 / EN 501304 /
loudspeakers, the use of the LBB 4440/00 Supervision EN 501214
Control Board in conjunction with the LBB 4441/00 Emissions acc. to EN 55103-1 / FCC-47 part 15B
and LBB 4443/00 Supervision Boards is
recommended. Emergency acc. to EN 60849 / EN 5416 /
ISO 724016
Functions
Maritime acc. to IEC 60945
Each amplifier channel in an LBB 442x/x0 or
PRSxPxxx Power Amplifier unit has an internal Region Certification
mechanical and electrical provision for an
Europe CPR EU_CPR
LBB 4442/00 master board. The slave board fits into
the Bosch range of loudspeakers and can be mounted CE
in the last speaker in the line, or in a separate housing CE COC
at the end of the line. The short-to-ground and short-
circuit detection for the lines are incorporated in the CE CertAlarm
power amplifier. Line faults are detected and reported CE DOP
within 100 s. The pilot tone generator for speaker
monitoring is generated in the amplifier and powers GL
the slave unit. Line monitoring can be switched on and Poland CNBOP
off from the configuration software.
2 | LBB 4442/00 Line Supervision Set

Installation/configuration notes Ordering information

The following loudspeakers have a provision for LBB 4442/00 Line Supervision Set
installing a supervision board: Master and slave PCB for supervisiing a single
loudspeaker line, the master is mounted in a Praesideo
Ceiling loudspeakers Column loudspeakers Sound projectors network connected power amplifier (one per channel),
LC1WM06E LBC 3210/00 LBC 3432/02 the slave is connected at the end of the loudspeaker
line.
LC1UM06E LA1UM20E1 LS1OC100E1 Order number LBB4442/00
LC1UM12E LA1UM40E1 Accessories

LC1UM24E Horn loudspeakers LBB 4446/00 Set of Supervision Board Brackets (10 pcs)
Aluminum brackets for mounting supervision slave
LBC 3510/40 LBC 3403/16 boards in a loudspeaker cabinet or cable box (set of
LBC 3520/40 LBC 3404/16 10 pieces).
Order number LBB4446/00
LBC 3530/40 LBC 3405/16

Cabinet loudspeakers LBC 3406/16

LBC 3011/41 LH110M10E

LBC 3011/51 LBC 3482/00

LB1UM06E1 LBC 3483/00

LBC 3018/01 LBC 3484/00

LB1UM20ED/L LH1UC30E

LB1UM50ED/L

LB3PC250

LB3PC350

Technical specifications

Mechanical

Slave

Dimensions (H x W X D) 16 x 80 x 60 mm (0.6 x 3.1 x 2.3 inch)

Weight 50 g (1.7 ounces)

Mounting 2 screws

Master

Dimensions (H x W X D) 17 x 60 x 50 mm (0.7 x 2.3 x 2 inch)

Weight 30 g (1.1 ounces)

Mounting Internally in all Praesideo Power


Amplifiers

Environmental

Operating temperature -5 C to +55 C (+23 to 131 F)

Storage temperature -20 C to +70 C (-4 to 158 F)

Humidity 15% to 90%

Air pressure 600 to 1100 hPa


Communications Systems | LBC 14x0/x0 MK Volume Controls and LBC 1430/10 Program Selector

LBC 14x0/x0 MK Volume Controls and


LBC 1430/10 Program Selector
www.boschsecurity.com

u 12 W, 36 W and 100 W versions

u Available in power-save or failsafe versions

u Built-in 24 VDC override relay

u Continuous rotating system

u Suitable for 3-wire and 4-wire systems

Bosch introduces a full range of volume controls and The design and color are unobtrusive in any interior.
program selectors to provide a complete public Ease of installation, operation and reliability is
address solution. optimized in the design.

Functions Interconnections
Screw connections
Operation
Public address systems are often used for both Certifications and approvals
announcements and background music distribution.
Volume controls can be used to adjust the level locally. Safety acc. to EN 60065
In addition to volume control, program selectors can Self-extinguishing acc. to UL 94 V0
also be installed to select five different programs
locally. In the event of an (emergency) announcement,
the built-in relay ensures that the message is
broadcast at a preset level, independent of the local
volume setting.
The volume controls come in three versions according
to power rating: 12 W, 36 W, and 100 W. The total load
of the loudspeakers connected to a volume control
may not exceed the rated power.
Each of the three versions is also available in two
versions. One is a power-saving, 4-wire volume
override (/10 models), where the override relay is
activated during an emergency call. The other is a
failsafe, 4-wire volume override (/20 models), where
the override relay is deactivated during an emergency
call.
2 | LBC 14x0/x0 MK Volume Controls and LBC 1430/10 Program Selector

Installation/configuration notes

LBC 1430/10 dimensions in mm


LBC 1400/10 and LBC 1400/20 dimensions in mm

LBC 1410/10 and LBC 1410/20 dimensions in mm

LM1-SMB-MK dimensions in mm

LBC 1420/10 and LBC 1420/20 dimensions in mm


3 | LBC 14x0/x0 MK Volume Controls and LBC 1430/10 Program Selector

LBC 1410/10 circuit diagram

LM1-SMB-MK detail

LBC 1410/20 circuit diagram

LBC 1400/10 circuit diagram

LBC 1420/10 circuit diagram

LBC 1400/20 circuit diagram

LBC 1420/20 circuit diagram


4 | LBC 14x0/x0 MK Volume Controls and LBC 1430/10 Program Selector

Mechanical

LBC 1400/10 and /20

Dimensions (W x H x D) 87 x 87 x 45.6 mm

Weight 226 g

Color White (RAL 9010)

LBC 1410/10 and /20

Dimensions (W x H x D) 87 x 87 x 45.6 mm

Weight 227 g

Color White (RAL 9010)

LBC 1430/10 circuit diagram LBC 1420/10 and /20

Dimensions (W x H x D) 87 x 147 x 61.5 mm


Technical specifications
Weight 512 g (including surface mounting box)
Electrical
Color White (RAL 9010)
LBC 1400/10 and /20
LBC 1430/10
Rated power 12 W
Dimensions (W x H x D) 87 x 87 x 32.9 mm
Input voltage 100 V
Weight 125 g
Attenuation steps 5 x 3 dB + off
Color White (RAL 9010)
Frequency response 50 Hz to 20 kHz (-1 dB)
LM1-SMB-MK
THD <0.5%
Dimensions (W x H x D) 87.3 x 87.3 x 50 mm
Current consumption 20 mA at 24 VDC
Weight 73 g
LBC 1410/10 and /20
Color White (RAL 9010)
Rated power 36 W
Environmental
Input voltage 100 V

Attenuation steps 8 x 3 dB + off Operating temperature -10 C to +55 C (+14 F to +131 F)

Frequency response 50 Hz to 20 kHz (-1 dB) Storage temperature -40 C to +70 C (-40 F to +158 F)

THD <0.5% Relative humidity <95%

Current consumption 20 mA at 24 VDC Ordering information


LBC 1420/10 and /20 LBC 1400/10 Volume Control
Rated power 100 W Volume control 12 W, MK installation type, built-in
24 VDC override relay, power-save version,
Input voltage 100 V 5 attenuation steps of 3 dB and off, white RAL 9010.
Attenuation steps 10 x 2 dB + off Order number LBC1400/10

Frequency response 50 Hz to 20 kHz (-1 dB) LBC 1400/20 Volume Control


Volume control 12 W, MK installation type, built-in
THD <0.5% 24 VDC override relay, failsafe version, 5 attenuation
Current consumption 20 mA at 24 VDC steps of 3 dB and off, white RAL 9010.
Order number LBC1400/20
LBC 1430/10
LBC 1410/10 Volume Control
Rated power 100 W Volume control 36 W, MK installation type, built-in
Input voltage 100 V 24 VDC override relay, power-save version,
8 attenuation steps of 3 dB and off, white RAL 9010.
Number of programs 5 programs + off Order number LBC1410/10

Potrebbero piacerti anche