Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
What Hippocrates said more than 2,400 years ago has to apply
for dental craftsmanship right up to the present day if perfection
is to be achieved. This mixture of qualities is the basis for our
development projects. Cooperating on an interdisciplinary basis,
our specialists work hand in hand with leading experts from
specialist dental areas for the development of our handpieces
and instruments. The result is out of the ordinary: Small, light,
high-powered and ergonomic products which in the truest
sense of the word make light of even the most complex
forms of treatments.
2
Turbines Motors Straight handpieces and
contra angles
3
Turbines
Precision and efficiency primarily this is what really makes profitable prepara-
tion possible at all. The TwinPower turbine series is able to achieve maximum
performance in all speed ranges because of its patented Morita twin rotors.
With their performance data, they come very close to high-speed rotors despite
air drive. It is not without reason that the TwinPower turbine series has received
numerous awards and is considered to be the performance leader in this sector.
Convincing performance
twice-over: twin rotor technology
Turbines with standard rotors are often mous power, our TwinPower turbines
unable to meet a lot of performance de- guarantee the constant high removal
mands with performance dropping off rate that makes it possible to achieve
under heavy loads. With our patented a more precise, efficient and profitable
twin rotor technology, we provide the preparation. At the same time, the low
intelligent answer to the demand for weight and ergonomic design are a guar-
maximum possible performance output antee for pleasant working conditions.
whilst at the same time retaining a small This enables you to concentrate more
head. With very high torque and enor- effectively on your treatment.
Compatibility:
Morita KaVo NSK Sirona W&H
4
Turbines
Trepanation on tooth 17
TwinPower Ultra M (PAR-4HUMX-O) Standard (TwinPower PAR-4HEX-O)
Output 25 W 22 W 20 W 20 W 18 W
Speed 350,000 rpm 370,000 rpm 370,000 rpm 370,000 rpm 370,000 rpm
at 0.2 MPa 30,000 rpm 30,000 rpm 30,000 rpm 30,000 rpm 30,000 rpm
Weight *
48 57 g 48 57 g 53 59 g 48 57 g 48 57 g
Rotor blades 40 36 36 36 40
Light
Air curtain Air curtain Air curtain Double air curtain 5 openings 3 openings
Morita (Art. 2530) Morita (Art. 2531) Morita (Art. 2541) Morita (Art. 2540)
KaVo (Art. 2530-100) KaVo (Art. 2531-100) KaVo (Art. 2541-100) KaVo (Art. 2540-100)
Morita (Art. 2531-045)
Coupling systems Sirona (Art. 2530-200) Sirona (Art. 2531-200) Sirona (Art. 2541-200) Sirona (Art. 2540-200)
KaVo (Art. 2531-145)
W&H (Art. 2530-300) W&H (Art. 2531-300) W&H (Art. 2541-300) W&H (Art. 2540-300)
NSK (Art. 2530-400) NSK (Art. 2531-400) NSK (Art. 2541-400) NSK (Art. 2540-400)
Zero suck-back
Quick stop
*
depending on the coupling system
6
Smallest space, unlimited Make the 1-to-1 com-
parison: Simply place
possibilities: Ultramini a turbine next to the
Even smaller, even more powerful. TwinPower turbine
The Ultramini TwinPower series com- (illustration in
original size).
bines a lot of advantages at the same
time: Low weight, best view of the
treatment area, adequate room for
movement during treatment of the
molars, but at the same time ideal ac-
cess to the patients mouth in pediatric
and geriatric dentistry. Despite the ex-
tremely compact design of the turbines,
standard burs up to a length of 20 mm
can be fitted at an output of 20 watts.
Because of its minimal construction
size, the treatment area is always well
in view. No other competitor is able to
offer such a high performance in combi-
nation with a minimized head volume
the patented Morita twin rotors make
it possible.
7
Straight and contra angle handpieces
8
Cleaning
Uncompromising hygiene
but still economical
Shaft
Designation Model series Max. rpm Length | Weight
Chuck type Application Instrument spray
Type no. TorqTech Transmission ratio Head x height
Light
FG shaft : 1.6 mm 94 mm | 68 g
CA-5IF-O max. 210,000 rpm 3-hole with
Pushbutton Preparation : 9.5 mm x
Art. 2450 1:5 spray filter
Light guide H: 14.0 mm
RA shaft 2.35 mm 94 mm | 67 g
CA-DC-O max. 42,000 rpm Preparation 1-hole with
Pushbutton : 9.5 mm x
Art. 2440 1:1 Prophylaxis spray filter
Light guide H: 13.3 mm
HP shaft 2.35 mm
Preparation
ST-DH max. 42,000 rpm or RA shaft 84 mm | 72 g
Prophylaxis 1-hole
Art. 2430 1:1 with spacer
Light technical work
No light
RA shaft 2.35 mm 94 mm | 55 g
CA-10RC-ENDO 14,5 mm max. 2,000 rpm Endodontics
Pushbutton : 9.3 mm x No spray
Art. 2460 10:1 (only Soaric)
No light H: 12.7 mm
94 mm | 67 g
CA-4R-PP max. 2,500 rpm Screw-in shaft
Prophylaxis : 8.0 mm x No spray
Art. 2415 4:1 No light
H: 8.5 mm
Stripping
max. 10,500 strokes EVA/Laminated Debonding 94 mm | 67 g
CA-4R-O-PF 1-hole with
per min. shaft Root planing : 7.8 mm x
Art. 2410 spray filter
4:1 Light guide Finishing H: 9.1 mm
Prophylaxis
Shaft
Designation Model series Max. rpm Length | Weight
Chuck type Application Instrument spray
Type no. Tokyo Transmission ratio Head x height
Light
Preparation | 12 g
QL26B RA shaft 2.35 mm
max. 36,900 rpm Prophylaxis : 10.5 mm x
Art. 3115 Pushbutton
(Head for US 121L) H: 14.3 mm
RA shaft 2.35 mm 90 mm | 74 g
QL26B + US 121L max. 36,900 rpm Preparation
Pushbutton : 10.5 mm x 1-hole
Art. 03110 1:1 Prophylaxis
Light guide H: 14.3 mm
HP shaft 2.35 mm
Preparation
ST 21U max. 41,000 rpm or RA shaft 80 mm | 70 g
Prophylaxis 1-hole
Art. 3100 1:1 with spacer
Light technical work
No light
10
8mm
13mm
11
Motors
Little masterpieces
finest engineering
42 mm
12
Motors
Speed range 100 40,000 rpm 100 40,000 rpm 100 40,000 rpm
Adjustable torque
TR-SII-O:
TR-SII-R-O: measurement function
Integrated endo-function
Auto Torque Control
Auto Apical Control
Motor casing removable and sterilizable Motor casing removable and sterilizable Motor completely sterilizable and/or
Hygiene
and/or thermo-disinfectable and/or thermo-disinfectable thermo-disinfectable
The following Morita treatment units The following Morita treatment units The motor can be connected without
are fitted with these micro motors: are fitted with these micro motors: problem to the turbine connection of
EMCIA UP: TR-SII-O Signo Treffert all treatment units
Soaric TR-SII-O and/or Actus 101
Compatibility
TR-SII-R-O SIGNO G10 II
All straight and contra angle handpieces All straight and contra angle handpieces All straight and contra angle handpieces
with ISO connectors can be used. with ISO connectors can be used. with ISO connectors can be used.
14
A simply moving form
Ergonomics play a central role in the light construction. This is the best pos-
development of our products so that sible way of preventing muscles getting
whatever the treatment, you can profit tired. In addition, their sophisticated and
from more efficiency and comfort. fail-proof technology is a further distin-
The best example: Our motors which guishing feature a guarantee for a long
rest perfectly in your hand because of service life.
their well-balanced and particularly
15
Scalers
Good vibrations
for perfect cleanliness
With their highly perfected form, our scalers are tuned precisely to every-
day dental practice and its wide range of challenges. All different forms of
deposits, scale and plaque are removed quickly and carefully. Irrespective
of whether you choose the air-powered AirSolfy or the ultrasonic-based
SC-3000/3000-O-LD both instruments have got one thing in common:
Their easy handling simplify even the most complex work stages.
16
Ultrasonic scalers
Simply a quick
and clean solution
Scalers: Specifications
Product name AirSolfy Solfy LED Solfy
Type designation AS2-4H-O-V SC-3000-O-LD SC-3000
27 kHz 27 kHz
Oscillating frequency 5,500 6,500 Hz
2 kHz 2 kHz
Compatible with all treatment units For treatment units For older models of Morita
using Morita quick couplings CP4-WO EMCIA UP treatment units
or CP4-WLD Soaric
Compatibility
The thread of the sound tips of nearly
all air scalers also fits the air scalers
from Morita
Weight 65 g 55 g 45 g
17
Ultrasonic tips for Morita ultrasonic scalers SC-3000/SC-3000-O-LD
Designation Designation
Illustration Application Illustration Application
Art. no. Art. no.
Removal of tooth
Universal tip Removal tip Removal of crowns,
cement, general
Art. 2465-001 Art. 2465-013 pins or cement residue
tartar removal
Removal of tooth
Straight tip Root planing tip L
cement, general Periodontology
Art. 2465-002 Art. 2465-012
tartar removal
Removal of tooth
Alveolus separation
Root canal tip cement and residue
during extraction Surgery
Art. 2465-003 from the root canal
Art. 2465-014
Planing root canal walls
Designation Designation
Illustration Application Illustration Application
Art. no. Art. no.
Fissure tip
(6 pcs./pack) Cleaning fissures
Art. 2465-007
Designation Designation
Illustration Application Illustration Application
Art. no. Art. no.
Designation
Illustration Application
Art. no.
Cleaning of
Rinsing connector
periodontal pockets,
Art. 2465-020
Root canal cleaning
18
Solfy U-file for endo-tip A or B
Designation Designation
Illustration Application ISO color marking
Art. no. Art. no.
Solfy file range consisting of: Art. 2466-013, 6 x ISO no. 15 ISO color marking: white
1 x ISO no. 15 Art. 2466-013, 6 x ISO no. 20 ISO color marking: yellow
Use with
1 x ISO no. 20
Endo-tip 105 Art. 2466-013, 6 x ISO no. 25 ISO color marking: red
1 x ISO no. 25
Endo-tip 90
1 x ISO no. 30
Art. 2466-013, 6 x ISO no. 30 ISO color marking: blue
1 x ISO no. 35
1 x ISO no. 40 Art. 2466-013, 6 x ISO no. 35 ISO color marking: green
Designation
Illustration Application Compatibility
Art. no.
Orthodontics
Designation
Illustration Application Compatibility
Art. no.
19
Scalers: Specifications
Sterilizable (autoclaveable)
Hygiene Thermo-disinfectable Sterilizable (autoclaveable) Sterilizable (autoclaveable)
Hygienic, ceramic-coated surface
Plaque removal
Plaque removal Plaque removal
Applications Prophylaxis Interdental care
Removal of subgingival plaque Removal of subgingival plaque
Tongue care
Autotuning
Autopower
Performance control on handpiece and Control on operator panel and by foot Control on operator panel and by foot
Control
by foot control of the treatment unit control of the treatment unit control of the treatment unit
20
AirSolfy winner on points Diversity for perfect work
against resistance With the interdental brushes you can off prophylactic treatment. Alongside
Our air-driven AirSolfy offers a complete effectively remove plaque in otherwise the various instrument advantages you
range of functions for perfect cleaning difficult to reach interdental spaces, while have with our air scaler, you also have
of the oral cavity. With it, all interdental at the same time protecting the soft tis- a very personal one: Its quiet operation
spaces and the tongue can be cleaned sue and gingiva. An additional aid in this also guarantees a pleasant atmosphere
comprehensively. This is made possible respect is also the halogen or LED light perfect for you and your patients.
by the ergonomically designed hand- which perfectly illuminates the working
piece where you can make a direct area for ideal visibility. Along with the vari-
selection of intensity settings and adjust ous interdental brushes, we are also able
pressure accordingly during treatment. to offer you scaler tips, root planing at-
tachments and tongue brushes to round
21
Polymerization lights
Polymerization lights
with real highlights
22
Arguments that become
immediately apparent
The lighting time of the PenCure poly- Our polymerization lights highlight the
merization lights can be selected as treatment area above all under unfavor-
required to ensure optimum adjustment able visibility and space conditions such
to actual treatment conditions. Different as the molar area. All PenCure models
operating modes are available for even are extremely compact and with their
greater flexibility to the varying condi- rotating heads guarantee comfortable
tions during dental treatment, such working conditions. PenCure 2000 can
as the high-power mode: With this, be adapted for different treatments
PenCure 2000 only needs 3 seconds for example for standard composites,
for curing whilst operating with high light composites and bleaching.
clinical effectiveness.
23
Polymerization lights: Specifications
4 programs: 4 programs:
High power High power
3 programmable memo-
Programs None Normal mode None Normal mode
ry slots
Pulse mode Pulse mode
Step mode Step mode
Integrated timer
Integrated timer Integrated timer Integrated timer
Exposure times 5/10/15/20/25/30/ 5/20 sec. manual
10/20/40 sec. 2/3/10/20 sec. 2/3/10/20 sec.
35/40 sec. manual
Lithium-ion battery can Lithium-ion battery, can Corded Lithium-ion battery, can
Handpiece be changed without be changed without Battery in worktop unit be changed without
Corded
power supply problem tools, contact-free tools, contact-free
by dentist charging charging
Approx. 60 lighting Approx. 400 lighting Approx. 180 lighting Approx. 400 lighting
Battery capacity
cycles 20 sec. cycles 3 sec. cycles 20 sec. cycles 3 sec.
Battery charge status Multistage in the hand- Multistage in the hand- Multistage in the hand-
LED
display piece display piece display piece display
Handpiece : 24 mm : 25 mm : 18 mm : 18 mm : 25 mm
dimensions L: 199 mm L: 205 mm L: 165 mm L: 175 mm L: 205 mm
Integrated
Air-cooled via
protection against Electronic Electronic Electronic Electronic
instrument hose
overheating
Apex locator
Exchangeable heads Exchangeable heads
DentaPort RootZX
Extras 380 430 nm and/or 380 430 nm and/or
Root canal preparation
430 490 nm 430 490 nm
motor DP-TR-ZX
24
Green light for blue power
With their constant performance, our which ensures constant performance at
polymerization lights allow a maximum different depths without any stray light
of efficiency: State-of-the-art LED loss. At its heart: the blue LED. Despite
technology is a guarantee for consistent this performance, the lithium-ion battery
curing in just seconds. And all of this provides energy for up to 400 lighting
with silent operation, low heat buildup cycles, the PenCure lamp itself achieves
and low energy consumption. Respon- a service life of up to 10,000 hours
sible for this performance is a specially an impressively long period of time for
developed, particularly depth-intensive efficient work.
lamp with parallel bundled light ray
25
Hand instruments
Reduced to a maximum
The oral cavity is a highly complex and, us that our instruments serve both:
above all, sensitive area. For this reason, the dentist and, of course, the patient
it is all the more important that the den- a decisive factor for the successful
tal practitioners hand instruments are achievement of any treatment. The more
easy to use and function with absolute careful and protective this cooperation
precision. They are intended to make functions, the better the result will be.
work easier and assist diagnostics and With Morita, you as dental practitioner
therapy to the best possible degree. This have the instruments in your hand that
starts with the correct ergonomics and are reduced to a maximum: Far away
goes way beyond the appropriate choice from impractical design, and well-
of materials. Above all, it is important for conceived for practical application.
26
Hand instruments: Specifications
Along with the normal forceps Forceps specially adapted to match the
function, suitable for grasping round root form; suitable for gentle extraction.
items such as paper tips, gutta percha Particularly designed for the Beach ex-
tips etc. traction method where the practitioner,
sitting in the 12 oclock position, can
make the extraction with the patient
Description lying down. Only one form for all teeth
of the upper and lower jaws.
27
Diagnostic and Imaging Equipment
Treatment Units
Endodontic Systems
Laser Equipment
Laboratory Devices
Auxiliaries
Distribution
J. Morita Europe GmbH
Justus-von-Liebig-Str. 27a
63128 Dietzenbach
Germany
T +49. 6074. 836 0, F +49. 6074. 836 299
www.morita.com/europe